0% found this document useful (0 votes)
63 views5 pages

D3G146HQ1362

The document provides detailed specifications for the D3G146-HQ13-62 EC centrifugal fan, including nominal data, technical descriptions, and performance curves. It highlights the fan's efficiency, power consumption, and operational parameters such as voltage, frequency, and temperature ranges. Additionally, it includes connection diagrams and compliance with relevant standards and regulations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views5 pages

D3G146HQ1362

The document provides detailed specifications for the D3G146-HQ13-62 EC centrifugal fan, including nominal data, technical descriptions, and performance curves. It highlights the fan's efficiency, power consumption, and operational parameters such as voltage, frequency, and temperature ranges. Additionally, it includes connection diagrams and compliance with relevant standards and regulations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

D3G146-HQ13-62 EC centrifugal fan

forward-curved
with housing (flange)

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
[email protected]
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRA 590344

General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen


Amtsgericht (court of registration) Stuttgart · HRB 590142

Nominal data

Type D3G146-HQ13-62
Motor M3G055-DF

Phase 1~
Nominal voltage VAC 230
Nominal voltage range VAC 200 .. 240
Frequency Hz 50/60

Method of obtaining data ml


Speed (rpm) min-1 2400
Power consumption W 230
Current draw A 1.8
Min. ambient temperature °C -25
Max. ambient temperature °C 50
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change

Data according to Commission Regulation (EU) 327/2011


Actual Req. 2015

01 Overall efficiency ηes % 47.9 32.5 09 Power consumption Ped kW 0.15


02 Measurement category A 09 Air flow qv m³/h 505
03 Efficiency category Static 09 Pressure increase pfs Pa 453
04 Efficiency grade N 59.4 44 10 Speed (rpm) n min-1 2715
05 Variable speed drive Yes 11 Specific ratio* 1.00
*
Data obtained at optimum efficiency level. Specific ratio = 1 + pfs / 100 000 Pa LU-134808
The ErP data is determined using a motor-impeller combination in a standardized measurement setup.

Item no. 52628-5-9980 · ENU · Change 96926 · Approved 2017-10-26 · Page 1 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D3G146-HQ13-62 EC centrifugal fan
forward-curved
with housing (flange)

Technical description

Weight 2.4 kg
Fan size 146 mm
Rotor surface Galvanized
Electronics housing material PP plastic
Impeller material PP plastic
Housing material PP plastic
Motor suspension Motor vibration-damped on both sides
Direction of rotation Counterclockwise, viewed toward rotor
Degree of protection Motor IP54, electronics IP20
Insulation class "F"
Moisture (F) / Environmental (H) H0+
protection class
Max. permitted ambient temp. + 80 °C
for motor (transport/storage)
Min. permitted ambient temp. for - 40 °C
motor (transport/storage)
Installation position Any
Condensation drainage holes None, open rotor
Mode S1
Motor bearing Ball bearing
Technical features - Output 10 VDC, max. 1.1 mA
- Tach output
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential safely disconnected from supply
- Thermal overload protection for motor
EMC immunity to interference According to EN 61000-6-2 (industrial environment)
EMC interference emission According to EN 61000-6-4 (industrial environment)
Touch current according to IEC <= 3.5 mA
60990 (measuring circuit Fig. 4,
TN system)
Electrical hookup With plug; Via terminal box
Motor protection Thermal overload protector (TOP) internally connected
With cable Variable
Protection class I (with customer connection of protective earth)
Conformity with standards EN 60335-1; EN 60335-2-31; CE
Approval VDE; EAC

Item no. 52628-5-9980 · ENU · Change 96926 · Approved 2017-10-26 · Page 2 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D3G146-HQ13-62 EC centrifugal fan
forward-curved
with housing (flange)

Product drawing

1 Header Stocko MSLO 7708-004-003-960 pluggable with Stocko EH 705-004-003-960 + RBB 8230.120 Ms
1.1 10 V
1.2 Tach
1.3 0-10 V / PWM
1.4 GND
2 Macromodul connector Stocko MSLO 9404-003-00A-960 pluggable with Stocko MFMP 9761-003-50A-960
2.1 L
2.2 N
2.3 PE
3 4x sheet metal nut for thread EN ISO 1478-ST4.8

Item no. 52628-5-9980 · ENU · Change 96926 · Approved 2017-10-26 · Page 3 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D3G146-HQ13-62 EC centrifugal fan
forward-curved
with housing (flange)

Connection diagram

No. Conn. Designation Color Function/assignment


CON10 10.1 L black Power supply 230 VAC, 50-60 Hz, see nameplate for voltage range
CON10 10.2 N blue Neutral conductor
CON10 10.3 PE green/yellow Protective earth
CON11 11.1 10 V/max. 1.1mA red Voltage output 10 V / 1.1 mA, electrically isolated, not short-circuit-proof
CON11 11.2 Tacho white Tach output: Open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA
CON11 11.3 0-10 V PWM yellow Control input 0-10 V or PWM, electrically isolated
CON11 11.4 GND blue GND connection for control interface

Item no. 52628-5-9980 · ENU · Change 96926 · Approved 2017-10-26 · Page 4 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D3G146-HQ13-62 EC centrifugal fan
forward-curved
with housing (flange)

Curves: Air performance 50 Hz


Druck p f s[Pa] für Rho=1,2kg/m^3

qv[cfm]
0 100 200 300 400 500 600 700 800
520

500 2
480
1,9
4
460 8
1,8 Measurement: LU-134808-1
440 Measurement: LU-132420-1
420 1,7 Measurement: LU-132422-1
Measurement: LU-132424-1
400 1,6
3 Air performance measured according to ISO
380
1,5 5801 installation category A. For detailed
360 12 information on the measurement setup,
1,4 contact ebm-papst. Intake sound level:
340 7 Sound power level according to ISO 13347 /
320 1,3 sound pressure level measured at 1 m
distance from fan axis. The values given are
300 1,2 valid under the specified measuring
conditions and may vary due to conditions of

p fs_E [IN H2O]


280 installation. For deviations from the standard
1,1
p f s[Pa]

configuration, the parameters have to be


260 2 checked on the installed unit.
1
240
11
220 0,9

200
16
6 0,8

180
0,7
160
0,6
140
15 10
120 0,5

100 0,4

80 14 0,3
60
0,2
p f s[P

40
p f s[P
p fs
pf

0,1
20
s[Pa

[Pa]

a]

13 9 5 1
a]

0 0
]

0 100 200 300 400 500 600 700 800 900 1.000 1.100 1.200 1.300 1.400
qv[m^3/h]

Measured values
U f n Ped I LpAin LwAin qV pfs qV pfs
V Hz min-1 W A dB(A) dB(A) m3/h Pa cfm in. wg
1 230 50 1790 189 1.47 62 74 1080 0 635 0.00
2 230 50 2400 230 1.80 62 73 920 250 540 1.00
3 230 50 2535 206 1.61 61 72 755 380 445 1.53
4 230 50 2705 164 1.30 61 72 550 460 325 1.85
5 230 50 1535 118 0.97 920 0 540 0.00
6 230 50 2040 154 1.21 800 191 470 0.77
7 230 50 2395 175 1.38 705 333 415 1.34
8 230 50 2695 169 1.33 545 454 320 1.82
9 230 50 1265 66 0.57 750 0 445 0.00
10 230 50 1675 85 0.71 655 128 385 0.51
11 230 50 1975 98 0.82 585 225 345 0.90
12 230 50 2380 118 0.96 485 354 285 1.42
13 230 50 970 29 0.27 570 0 335 0.00
14 230 50 1275 38 0.34 490 72 290 0.29
15 230 50 1490 43 0.37 430 122 255 0.49
16 230 50 1800 52 0.44 360 199 210 0.80
U = Power supply · f = Frequency · n = Speed (rpm) · Ped = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side
qV = Air flow · pfs = Pressure increase

Item no. 52628-5-9980 · ENU · Change 96926 · Approved 2017-10-26 · Page 5 / 5