0% found this document useful (0 votes)
311 views20 pages

Tds LDC Frls Rev

The document is a technical data sheet for various flexible cables manufactured by Polycab India Limited, detailing specifications such as cable code, conductor material, insulation properties, and current ratings for different sizes (0.5 to 6 Sq.mm) at a rated voltage of 1100 volts. Each cable variant includes information on resistance, maximum temperature, tensile strength, and compliance with relevant standards. The document emphasizes the FR-LSH properties of the insulation material and provides core identification colors.

Uploaded by

nickjaff1216
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
311 views20 pages

Tds LDC Frls Rev

The document is a technical data sheet for various flexible cables manufactured by Polycab India Limited, detailing specifications such as cable code, conductor material, insulation properties, and current ratings for different sizes (0.5 to 6 Sq.mm) at a rated voltage of 1100 volts. Each cable variant includes information on resistance, maximum temperature, tensile strength, and compliance with relevant standards. The document emphasizes the FR-LSH properties of the insulation material and provides core identification colors.

Uploaded by

nickjaff1216
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

Document ID: TE/QMS/F/02

Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C.75S


Sr.No. Description Unit 1C X 0.75 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 0.75
Max. D.C Cond. Resistance at 20
c) Ohm/km 26.0
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
a) Material PVC Type 'D' with FR-LSH Propertes
b) Thickness - Nominal mm 0.6
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 2.8
0
7 Current rating at 40 C Amps 7
Max. conductor temp. under
8 °C 70
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 4
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C0.5S


Sr.No. Description Unit 1C X 0.5 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 0.5
Max. D.C Cond. Resistance at 20
c) Ohm/km 39.0
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
a) Material PVC Type 'D' with FR-LSH Propertes
b) Thickness - Nominal mm 0.6
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 2.6
0
7 Current rating at 40 C Amps 4
Max. conductor temp. under
8 °C 70
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 3
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C001S


Sr.No. Description Unit 1C X 1Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 1.0
Max. D.C Cond. Resistance at 20
c) Ohm/km 19.5
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
a) Material PVC Type 'D' with FR-LSH Propertes
b) Thickness - Nominal mm 0.6
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 3.0
0
7 Current rating at 40 C Amps 12
Max. conductor temp. under
8 °C 70
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 5
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C1.5S


Sr.No. Description Unit 1C X 1.5 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 1.5
Max. D.C Cond. Resistance at 20
c) Ohm/km 13.3
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
a) Material PVC Type 'D' with FR-LSH Propertes
b) Thickness - Nominal mm 0.6
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 3.4
0
7 Current rating at 40 C Amps 16
Max. conductor temp. under
8 °C 70
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 8
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C2.5S


Sr.No. Description Unit 1C X 2.5 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 2.5
Max. D.C Cond. Resistance at 20
c) Ohm/km 7.98
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
a) Material PVC Type 'D' with FR-LSH Propertes
b) Thickness - Nominal mm 0.7
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 4.1
0
7 Current rating at 40 C Amps 22
Max. conductor temp. under
8 °C 70
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 13
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C004S


Sr.No. Description Unit 1C X 4 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 4
Max. D.C Cond. Resistance at 20
c) Ohm/km 4.95
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
a) Material PVC Type 'D' with FR-LSH Propertes
b) Thickness - Nominal mm 0.8
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 4.8
0
7 Current rating at 40 C Amps 29
Max. conductor temp. under
8 °C 70
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 20
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C006S


Sr.No. Description Unit 1C X 6 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 6
Max. D.C Cond. Resistance at 20
c) Ohm/km 3.30
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
a) Material PVC Type 'D' with FR-LSH Propertes
b) Thickness - Nominal mm 0.8
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 5.3
0
7 Current rating at 40 C Amps 37
Max. conductor temp. under
8 °C 70
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 31
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C010S


Sr.No. Description Unit 1C X 10 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 10
Max. D.C Cond. Resistance at 20
c) Ohm/km 1.91
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.0
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 7.0
7 Current rating at 400C Amps 62
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 51
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C016S


Sr.No. Description Unit 1C X 16 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 16
Max. D.C Cond. Resistance at 20
c) Ohm/km 1.21
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.0
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 8.1
7 Current rating at 400C Amps 82
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 82
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C025S


Sr.No. Description Unit 1C X 25 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 25
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.780
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.2
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 10.2
7 Current rating at 400C Amps 104
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 127
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C035S


Sr.No. Description Unit 1C X 35 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 35
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.554
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.2
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 11.7
7 Current rating at 400C Amps 132
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 178
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C050S


Sr.No. Description Unit 1C X 50 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 50
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.386
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.4
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 13.9
7 Current rating at 400C Amps 174
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 255
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C070S


Sr.No. Description Unit 1C X 70 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 70
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.272
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.4
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 16.0
7 Current rating at 400C Amps 258
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 357
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C095S


Sr.No. Description Unit 1C X 95 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 95
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.206
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.6
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 18.2
7 Current rating at 400C Amps 312
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 484
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C120S


Sr.No. Description Unit 1C X 120 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 120
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.161
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.6
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 20.2
7 Current rating at 400C Amps 366
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 612
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C150S


Sr.No. Description Unit 1C X 150 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 150
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.129
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 1.8
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 22.5
7 Current rating at 400C Amps 426
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 764
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C185S


Sr.No. Description Unit 1C X 185 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 185
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.106
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 2.0
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 24.9
7 Current rating at 400C Amps 498
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 943
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C240S


Sr.No. Description Unit 1C X 240 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 240
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.0801
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 2.2
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 28.4
7 Current rating at 400C Amps 600
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 1223
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C300S


Sr.No. Description Unit 1C X 300 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 300
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.0641
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 2.4
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 31.0
7 Current rating at 400C Amps 702
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,IS 694/2010,
Standards to which the cables
10 etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 1529
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.
Document ID: TE/QMS/F/02
Rev. No. : 00 |Issued Date : 02/04/2018

Technical Data Sheet of Flexible Cables

Cable Code LDIS09CYUAYL001C400S


Sr.No. Description Unit 1C X 400 Sq.mm
1 Manufacturer Name Polycab India Limited
2 Brand Name POLYCAB
3 Rated Voltage Volts 1100
4 CONDUCTOR
Plain annealed high conductivity
a) Material Flexible copper conductor as per Class
5 of IS 8130/2013 latest
b) Conductor Size Sq.mm 400
Max. D.C Cond. Resistance at 20
c) Ohm/km 0.0486
Deg. C.
d) Shape of Conductor Bunched Circular
5 INSULATION
HR-PVC Type 'C' with FR-LSH
a) Material
Propertes
b) Thickness - Nominal mm 2.6
Red | Yellow | Blue | Black | Green
c) Core Identification | Grey |Brown |White |Orange
|Pink |Violet |Yellow/Green
d) FR-LSH PROPERTIES
Oxygen Index Min. 29% as per ASTM D- 2863
Temperature Index Min. 250 Deg.C as per ASTM D- 2863
Smoke Density Rating Max. 60% as per ASTM D- 2843
Acid Gas Generation Max. 20% as per IEC- 754- 1
6 Maximum Overall Diameter mm 33.2
7 Current rating at 400C Amps 834
Max. conductor temp. under
8 °C 85
normal operating conditions
Max conductor temp at the
9 °C 160
termination of short circuit
As per IS 8130/2013,Generally IS
Standards to which the cables
10 694/2010, etc. with latest up to date
confirm
amendments
Recommended minimum bending 8 times the overall diameter of the
11
radius in mm cable
Max. Tensile strength when
12 Kg 2040
pulled with pulling eye
POLYCAB 1100 V SQ.MM
13 Printing
HR-FR-LSH

Note:-The values given above are subject to


tolerances as per the relevant standards.