H3C S5560X-EI Series Converged Gigabit Switches Datasheet
H3C S5560X-EI Series Converged Gigabit Switches Datasheet
Product overview
H3C S5560X-EI is a series of intelligent Layer 3 managed GE switches with outstanding performance, high port density,
and ease of installation. It offers the following benefits:
Seamless wired and wireless integration on a unified switching platform. The license-based wireless access
controller functionality enables wired and wireless local forwarding at the access layer, eliminates the bandwidth
bottlenecks typical of a wireless controller, expands wireless deployment, and saves TCO.
Reliable hardware design with modular dual power supply and dual FAN design.
Embedded SmartMC delivers the easiest and simplest network operation and management solution.
Advanced free of charge enterprise features and functions like layered security, VxLAN, IRF and Macsec
High-density 10/100/1000Base-T autosensing Ethernet ports or 10GE SFP + fiber ports on board
One expansion slot,up to 9 optional interface cards that provide high density giga, 10GE, 25GE, 40GE and Multi-
Giga access.
As an access device on enterprise networks, the switch can provide GE connections for desktop applications. It can also
be used as a core device on small- and medium-sized enterprise networks. On MAN or industrial networks, it provides
GE access for users and transmits the aggregated traffic from downstream switches to core switches.
S5560X-30F-EI—Provides 24 × SFP ports (including 8 × combo interfaces), 4 × 10G/1G BASE-X SFP+ ports, 1 ×
expansion slot, 2 × fan tray slots, and 2 × power module slots.
S5560X-54F-EI—Provides 48 × SFP ports, 4 × 10G/1G BASE-X SFP+ ports, 1 × expansion slot, 2 × fan tray slots,
and 2 × power module slots.
S5560X-54S-EI—Provides 48 × 10/100/1000BASE-T ports, 4 × 10G/1G BASE-X SFP+ ports, and 2 × 40G QSFP+
ports, fixed AC&DC power supply
S5560X-30C-EI S5560X-54C-EI
S5560X-30F-EI S5560X-54F-EI
S5560X-30C-PWR-EI S5560X-54C-PWR-EI
S5560X-34S-EI S5560X-54S-EI
2
DATA SHEET
High scalability: With IRF2, plug-n-play device aggregation can be achieved by adding one or more switches into
the IRF2 stack and enabling IRF2 stacking on the new device. New devices can be managed with a single IP, and
upgraded at the same time to reduce network expansion cost.
High reliability: The IRF2 patented 1:N backup technology allows each slave device in the IRF2 stack to serve as
the backup of the master, creating control and data link redundancy, as well as uninterrupted layer-3 forwarding.
This improves the reliability, avoids unplanned business downtime and serves to improve overall performance.
When the master device fails, traffic remains uninterrupted.
Load balancing: IRF2 supports cross-device link aggregation, upstream and downstream can be connected to
more than one physical link, which creates another layer of network redundancy and boosts the network
resource utilization.
Availability: H3C Implements IRF2 through standard Forty Gigabit Ethernet (40GE) or Ten Gigabit Ethernet (10GE)
3
DATA SHEET
ports which allocates bandwidth for business and application access and reasonably splits local traffic and
upstream traffic. IRF2 rules not only able to obeyed within and across the rack, but also across the LAN
Single point of management—An IRF 3.1 system is accessible at a single IP address on the network. You can use
this IP address to log in through any network port to configure and manage all the devices in the system.
Unified security policy—The whole IRF 3.1 system enforces the same security policy, avoiding the policy conflicts
that typically occur when the network devices are configured one by one.
Simplified network topology—IRF 3.1 combines the access and distribution layers, streamlining the conventional
three-layer network model to two layers and making cabling easier.
Simplified service deployments—An IRF 3.1 system is a single node for IP services, routing protocols, VLANs, and
other services. You can deploy services on it in the same way you work with a single device. This significantly
reduces service deployment complexities and the risks of inadvertent deployment errors when numerous devices
are involved.
Easy scalability and maintenance—IRF 3.1 enables plug-and-play of PEXs without network topology changes and
automatically pushes configuration and software from the parent fabric to the PEXs. IRF 3.1 also reduces the
numerous points of failure into one, improving the efficiency in troubleshooting.
Software-defined networking
Software-defined networking (SDN) is an innovative network architecture that separates the control plane from the
forwarding plane, typically by using OpenFlow. SDN significantly simplifies network management, reduces maintenance
complexity and cost, enables flexible traffic management, and offers a good platform for core network and application
innovations.
The S5560X-EI network switch series supports a large network flow table. Combined with H3C SDN controller, it can
easily implement a two-layer network architecture and quickly add functions in existing network in order to drastically
reduces network management complexity while substantially lowers network maintenance cost.
4
DATA SHEET
The switch supports unified MAC address authentication, 802.1x authentication, and portal authentication; dynamic or
static binding of user identifiers such as user account, IP address, MAC address, VLAN, and port number; and dynamic
application of user profiles or policies (such as VLAN, QoS, and ACL) on users. Using the switch in conjunction with H3C
IMC, you can manage and monitor online users in real time and take prompt action on illegitimate behaviors.
The switch offers a large number of inbound and outbound ACLs and VLAN-based ACL assignment.
The switch supports Unicast Reverse Path Forwarding (uRPF), which protects a network against source spoofing attacks,
preventing DoS and DDoS attacks.
MACsec
MACsec is an ideal hop-by-hop link-layer security protocol for Ethernet networks, which are typically insecure. It
provides the following services:
Data encryption—Encrypts data over the Ethernet link to protect data against security issues such as
eavesdropping.
Antireplay—Prevents packets from being intercepted and modified en route to protect the network against
unauthorized access.
Client-oriented—Protects data transmission over the link between the client and its access device.
Device-oriented mode—Protects data transmission over the link between two peering devices.
The switch can cooperate with H3C iNode client and core switches such as S10500 and S7500E to provide a complete
MACsec solution.
High availability
The switch offers the following hardware high availability features:
Automatically monitors power module and fan tray status, and generates alarms when a power or temperature
event occurs.
In addition to hardware redundancy, the switch provides a variety of node and link redundancy and protection
mechanisms, including:
Smart Link, which protects faster link switchover for dual uplink network.
5
DATA SHEET
Packet filtering based on packet header fields from Layer 2 through Layer 4, including source MAC, destination
MAC, source IP, destination IP, TCP/UDP port number, protocol type, and VLAN.
Flexible queuing and scheduling algorithms configured on a per-port or per-queue basis, including strict priority
(SP), weighted round robin (WRR), SP+WRR, weighted fair queuing (WFQ), and SP+WFQ.
Port mirroring in both outbound and inbound directions for network monitoring and troubleshooting.
The S5560X-EI switch supports SPAN/RSPAN/ERSPAN mirroring, and multiple mirroring ports so that network traffic
can be analyzed to carry out corresponding management and maintenance measures and traffic of network services
and applications is visible. The S5500X-EI switch provides network stream analysis reports, which help users to promptly
optimize the network structure and adjust resource deployment.
Intelligent operation: once the switch is powered on and SmartMC function is enabled, topology will be created
automatically and user can go enhanced web GUI to check the latest status.
Centralized management: all management can be achieved via commander switch such as centralized
configuration backup, and software version management, increasing working efficiency.
One key device replacement: in case of one switch failure, the new added same type switch can download the
same configuration and work as old switch immediately
Specifications
Item S5560X-30C-EI S5560X-54C-EI S5560X-30F-EI S5560X-54F-EI
Switching
598Gbps 598Gbps 598Gbps 598Gbps
capacity
6
DATA SHEET
Packet
forwarding 216 Mpps 252 Mpps 216 Mpps 252 Mpps
rate
43.6 × 440 × 360 mm 43.6 × 440 × 360 mm 43.6 × 440 × 360 mm 43.6 × 440 × 360 mm
Dimensions (H
(1.72 × 17.32 × 14.17 (1.72 × 17.32 × 14.17 (1.72 × 17.32 × 14.17 (1.72 × 17.32 × 14.17
× W × D)
in) in) in) in)
Weight ≤ 6.7 kg (14.77 lb) ≤ 7.0 kg (15.43 lb) ≤ 6.6 kg (14.55 lb) ≤ 6.7 kg (14.77 lb)
Flash/SDRAM 512MB/2GB
Management
1
Ethernet ports
Only the Micro-USB console port is available when you connect both ports.
24 ×
48 ×
10/100/1000Base-T 24 × SFP ports
10/100/1000Base-T
autosensing Ethernet (including 8 combo 48 × SFP ports
Service ports autosensing Ethernet
ports (including 8 interfaces) 4 × 10G SFP+ ports
ports
combo interfaces) 4 × 10G SFP+ ports
4 × 10G SFP+ ports
4 × 10G SFP+ ports
Expansion
1
slots
PSR150-A1&PSR150-A2:
AC input
Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz
voltage
Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz
PSR150-D1:
7
DATA SHEET
Min. power Dual AC inputs: 29 W Dual AC inputs: 31 W Dual AC inputs: 29 W Dual AC inputs: 37 W
consumption Single DC input: 24 W Single DC input: 24 W Single DC input: 24 W Single DC input: 30 W
Operating
0ºC to 45ºC (32°F to 113°F)
temperature
Operating
5% RH to 95% RH, non-condensing
humidity
OpenFlow 1.3
Meter
8
DATA SHEET
Port-based VLAN
MAC-based VLAN
Protocol-based VLAN
VLAN mapping
Voice VLAN
MVRP
STP/RSTP/MSTP
Loop-free
redundant Smart Link
Layer 2 RRPP
topology
G.8032 Ethernet ring protection switching (ERPS)
DHCP client
DHCP snooping
DHCP server
IRF2
Distributed device management, distributed link aggregation, and distributed resilient routing
IRF2
Stacking through standard Ethernet interfaces
Static routing
IP routing OSPFv1/v2/v3
VRRP/VRRPv3
9
DATA SHEET
Manual tunnel
6to4 tunnel
ISATAP tunnel
GRE tunnel
PIM Snooping
MLD Proxy
Multicast VLAN
Multicast
IGMP v1/v2/v3 and MLD v1/v2
Flow mirroring
Traffic classification based on source MAC, destination MAC, source IP, destination IP, TCP/UDP
port, and VLAN
QoS/ACL Rate limit for receiving and transmitting packets (a minimum CIR of 8 Kbps)
Packet redirection
Flexible queue scheduling algorithms based on both port and queue, including SP, WRR, and
SP+WRR
WRED
RADIUS authentication
SSH 2.0
10
DATA SHEET
Port security
EAD
DHCP snooping
uRPF
IP/Port/MAC binding
Plaintext authentication and MD5 authentication for OSPF and RIPv2 packets
SNMP v1/v2/v3
LLDP
Loopback detection
ICES-003 CLASS A
EMC
VCCI CLASS A
CISPR 32 CLASS A
11
DATA SHEET
CISPR 24
EN 55024
EN 61000-3-2
EN 61000-3-3
GB/T 9254
YD/T 993
UL 60950-1
IEC 60950-1
Safety EN 60950-1
AS/NZS 60950-1
GB 4943.1
Specifications (continued)
Switching
598Gbps 598Gbps 598Gbps 598Gbps
capacity
Packet
forwarding 216 Mpps 252 Mpps 216 Mpps 252 Mpps
rate
43.6 × 440 × 460 mm 43.6 × 440 × 460 mm 43.6 × 440 × 260 mm 43.6 × 440 × 260 mm
Dimensions (H
(1.72 × 17.32 × 18.11 (1.72 × 17.32 × 18.11 (1.72 × 17.32 × 10.24 (1.72 × 17.32 × 10.24
× W × D)
in) in) in) in)
Weight ≤ 9.2 kg (20.28 lb) ≤ 9.6 kg (21.16 lb) ≤ 3.6 kg (7.94 lb) ≤ 3.9 kg (8.60 lb)
Flash/SDRAM 512MB/2GB
Management
1
Ethernet ports
Only the Micro-USB console port is available when you connect both ports.
12
DATA SHEET
28 ×
24 × 48 × 10/100/1000Base-T 48 × 10/100/1000Base-
10/100/1000Base-T 10/100/1000Base-T autosensing Ethernet T autosensing Ethernet
Expansion
1 1 N/A N/A
slots
MAC address
64000 entries
table
PSR360-56A/PSR720-56A:
AC input Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz
voltage PSR1110-56A: Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz
Min. power Single AC input: 31 W Single AC input: 33 W Single AC input: 19 W Single AC input: 22 W
13
DATA SHEET
Operating
0ºC to 45ºC (32°F to 113°F)
temperature
Operating
5% RH to 95% RH, non-condensing
humidity
OpenFlow 1.3
Meter
VXLAN L2 switching
VXLAN L3 routing
VXLAN VTEP
VXLAN
IS-IS+ENDP distributed control plane
14
DATA SHEET
Port-based VLAN
MAC-based VLAN
Protocol-based VLAN
VLAN mapping
Voice VLAN
MVRP
STP/RSTP/MSTP
Loop-free
redundant Smart Link
Layer 2 RRPP
topology
G.8032 Ethernet ring protection switching (ERPS)
DHCP client
DHCP snooping
DHCP server
IRF2
Distributed device management, distributed link aggregation, and distributed resilient routing
IRF2
Stacking through standard Ethernet interfaces
Static routing
OSPFv1/v2/v3
15
DATA SHEET
VRRP/VRRPv3
PMTU
6to4 tunnel
ISATAP tunnel
GRE tunnel
PIM Snooping
MLD Proxy
Multicast VLAN
Multicast
IGMP v1/v2/v3 and MLD v1/v2
Flow mirroring
Policy-based Mirroring
Traffic Mirroring
Traffic classification based on source MAC, destination MAC, source IP, destination IP, TCP/UDP
port, and VLAN
Rate limit for receiving and transmitting packets (a minimum CIR of 8 Kbps)
Packet redirection
Flexible queue scheduling algorithms based on both port and queue, including SP, WRR, and
16
DATA SHEET
WRED
Guest VLAN
RADIUS authentication
SSH 2.0
Port isolation
Port security
Security EAD
DHCP snooping
uRPF
IP/Port/MAC binding
Plaintext authentication and MD5 authentication for OSPF and RIPv2 packets
SNMP v1/v2/v3
LLDP
Loopback detection
17
DATA SHEET
VCCI CLASS A
CISPR 32 CLASS A
EN 55032 CLASS A
CISPR 24
EN 55024
EN 61000-3-2
EN 61000-3-3
GB/T 9254
YD/T 993
UL 60950-1
IEC 60950-1
Safety EN 60950-1
AS/NZS 60950-1
GB 4943.1
Ordering Information
Product ID Product Description
18
DATA SHEET
Fan
Power supply
Modules
Wireless license
Transceivers
SFP-GE-SX-MM850-
1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC)
A
SFP-GE-LX-SM1310-
1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC)
A
19
DATA SHEET
SFP-GE-LH40-
1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC)
SM1310
SFP-GE-LH40-
1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC)
SM1550
SFP-GE-LH80-
1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC)
SM1550
SFP-GE-LH100-
1000BASE-LH100 SFP Transceiver, Single Mode (1550nm, 100km, LC)
SM1550
SFP-GE-LX-SM1310-
1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1310/RX1490, 10km, LC)
BIDI
SFP-GE-LX-SM1490-
1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1490/RX1310, 10km, LC)
BIDI
SFP-XG-LH40-
SFP+ Module(1550nm,40km,LC)
SM1550
SFP-XG-LX-SM1310-
SFP+ Module(1310nm,10km,LC)
E
SFP-XG-SX-MM850-
SFP+ Module(850nm,300m,LC)
E
QSFP-40G-LR4-
40GBASE-LR4 QSFP+ Optical Transceiver Module
WDM1300
Cables
20
DATA SHEET
OP-MPO8-MPO8-10-
Fiber connector,MPO(8 core)/PC,MPO(8 core)/PC,Multimode(OM3),3.0mm,10.0m
M
OP-MPO8-MPO8-50-
Fiber connector,MPO(8 core)/PC,MPO(8 core)/PC,Multimode(OM3),3.0mm,50.0m
M
OP-MPO8-MPO8-
Fiber connector,MPO(8 core)/PC,MPO(8 core)/PC,Multimode(OM3),3.0mm,100.0m
100-M
OP-MPO8-MPO8-
Fiber connector,MPO(8 core)/PC,MPO(8 core)/PC,Multimode(OM3),3.0mm,200.0m
200-M
New H3C Technologies Co., Limited Copyright © 2017 New H3C Technologies Co., Limited Reserves all rights
Disclaimer: Though H3C strives to provide accurate information in this document, we cannot guarantee that details do not contain any technical error or printing
Beijing base error. Therefore, H3C cannot accept responsibility for any inaccuracy in this document. H3C reserves the right for the modifi cation of the contents herein without
prior notification
8 GuangShun South Street, Chaoyang District,Beijing
Zip: 100102
Hangzhou base
Zip: 310052
Tel: +86-571-86760000
Fax: +86-571-86760001
21