0% found this document useful (0 votes)
28 views16 pages

Design of Footing

The document outlines the manual design procedure for a footing of a G+5 building using I.S. 456:2000, detailing calculations for load, area, bending moments, depth, and reinforcement requirements. Key results include a footing size of 2.3m x 2.6m, a required depth of 600mm, and reinforcement specifications for both X and Y directions. Safety checks for one-way and two-way shear are also performed, confirming that the design is safe under the specified conditions.

Uploaded by

nathemanjusha3
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views16 pages

Design of Footing

The document outlines the manual design procedure for a footing of a G+5 building using I.S. 456:2000, detailing calculations for load, area, bending moments, depth, and reinforcement requirements. Key results include a footing size of 2.3m x 2.6m, a required depth of 600mm, and reinforcement specifications for both X and Y directions. Safety checks for one-way and two-way shear are also performed, confirming that the design is safe under the specified conditions.

Uploaded by

nathemanjusha3
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

MANUAL DESIGN OF FOOTING

DESIGN OF FOOTING
DESIGN OF FOOTING OF G+5 BUILDING PROCEDURE USING
I.S. 456:2000 :-
Given:-
1) Grade of Concrete = M20
2) Grade of Steel = Fe500
3) Clear Cover to Reinforcement (c) = 50 mm
4) Column Dimension = 300 X 600 mm
5) Net Soil Bearing Capacity (S.B.C.) = 300 kN/m2

Assume Axial Load (P) from Column to Footing = 1500 kN


Step 1 :- Load Calculation :-

Load From Column = 1500 kN


Self Weight of Footing = Assume 10% of the column load
= (10/100) X 1500
= 150 kN
-----------------------------------------------------------
Total Weight (W) = 1650 kN
Step 2 :- Area of Footing (A):-

Area of Footing (A) = Total Weight (W) / Net Soil Bearing Capcity (S.B.C.)
= 1650 / 300
= 5.5 m2
Take Equal Projections From Both Sides,

5.5 = (0.6 + 2x) . (0.3 + 2x)


5.5 = 0.18 +1.2x + 0.6x + 4x2
5.5 = 0.18 +1.8x + 4x2
Therefore, by Solving Above Equation,
x = 0.95 m
Take Projection of 1 m on Both Side.
Therfore, Size of Footing = (0.3+ 2 X 1 ) & (0.6 + 2 X 1)
= 2.3 X 2.6 m

Therefore Area of Footing Provided = 2.3 X 2.6


= 5.98 m2
Step 3 :- Upward Soil Pressure (Pau) :-
Pau = (Factored Load of Column / Actual Area of Footing Provided)
= 1.5 X 1500 / 5.98
Pau= 376.25 kN/m2
Step 4 :- Bending Moment (B.M.) :-
The Critical Section for B.M. Along the Column Face as Shown in the Figure,

 From X-axis :-

Cx =

= (2.6 – 0.6) / 2
=1m
Consider a Strip of 1m.
2
Therefore, Mux = [Pau X 1 X (Cx /2)]
= [376.25 X 1 X (12 /2)]
Mux = 188.125 kN.m
 From Y-axis :-

Cy =

= (2.3 – 0.3) / 2
=1m
2
Therefore, Muy = [Pau X 1 X (Cy /2)]
= [376.25 X 1 X (12 /2)]
Muy = 188.125 kN.m
Step 5 :- Depth of Footing Required (dreq) :-

Equate The Maximum Bending Moment (Max. of Mux & Muy) With Limiting Moment
of Resistance ,
Consider a Strip of 1m.
Mumax = Mulim

188.125 X 106 = 0.133 fck.b.dreq2


188.125 X 106 = 0.133 X 20 X 1000 X dreq2
dreq = 265.94 mm
Provide 12 mm Diameter Bars at a Clear Cover of 50 mm.
Therefore, Overall Depth (D) = 265.94 + 50 + (12/2)
= 321.94 mm ≈ 600 mm …(rounded -off on higher side)
Overall Depth (D) = 450 mm
Therefore, Effective Depth Provided (dprovided) = 600 – 50 – (12/2) = 544 mm
Step 6 :- Area of Steel Calculation (Ast):-
Astx Along X-Direction :-

Astx =

Astx =

Astx = 826.8 mm2


Provide 12 mm Diameter Bars.

Spacing = = 136.8 mm ≈ 125 mm

Provide 12 mm Diameter Bars @ 125 mm c/c


Asty Along Y-Direction :-

Asty =

Asty =

Asty = 826.8 mm2

Provide 12 mm Diameter Bars.

Spacing = = 136.8 mm ≈ 100 mm

Provide 12 mm Diameter Bars @ 100 mm c/c.


Step 7 :- Check For One Way Shear :-
The Critical Section for One Way Shear is Taken at a Distance of ‘d’ From Column
Periphery.
The Offset x = Cx – d = 1 – 0.544 = 0.456 m
Similarly, y = Cy – d = 1 – 0.544 = 0.456 m

Depth of Footing at Critical Section (d’) = 544 mm


Shear Force Along X-Direction :-
Vux = x . L . Pau = 0.456 X 1 X 376.25 = 171.57 kN

Shear Force Along Y-Direction :-


Vuy = y . B . Pau = 0.456 X 1 X 376.25 = 171.57 kN

Vumax = 209.2 kN

 Nominal Shear Stress (τv) :-


τv = Vumax/ b’.d’ = [(171.57 X 103) / (1000 X 544)] = 0.32 N/mm2
 % of Steel (Pt) :-
Pt = 100 Astmax / b’d’ = [(100 X 1130) / (1000 X 544)] = 0.21 %

 Design Shear Stress (τc) :- (Refer Table No. 19, Page No.73, I.S. 456 : 2000)
Pt τc ( For M20)
τc = 0.32 N/mm2 > 0.32 N/mm2
<0.15 0.28
As, τc > τv … Safe in One Way Shear
0.21 ?
0.25 0.36
Step 8 :- Check For Two Way Shear :-
The Critical Section for Two Way Shear is Taken at a Distance of ‘d/2’ From Column
Periphery.

Depth of Footing at Critical Section (D’) = 750 mm


Effective Depth at Critical Section = d’ = 600 – 50 – (12/2 ) = 544 mm
b’ = 2 . Perimeter of Critical Section
= 2 X (1144 + 844)
= 3976 mm
Shear Force on Shaded Area is Given by,
Vu = (Footing Area – Critical Section Area) . Upward Soil Pressure
Vu = [(2.6 X 2.3) – (1.144 X 0.844)] X 376.25
Vu = 1886.7 kN

 Nominal Shear Stress (τv) :-


τv = Vumax/ b’. d’ = [(1886.7 X 103) / (3976 X 544)] = 0.87 N/mm2

Design Shear Stress (τc’) :-

τc' = ks. (0.25√fck )

Where, ks= Minimum of, i) 1


ii) 0.5 + βc = 0.5 + 0.5 = 1
Where, βc = (Breadth / Depth)column = 300 / 600 = 0.5
Therefore, ks = 1

Therefore, τc' = 1 X (0.25√20) = 1.118 N/mm2 > 0.87 N/mm2


As, τc > τv … Safe in Two Way Shear