Electronic
pressure measurement
Electronic pressure switch with display
For sanitary applications
Model PSA-31
WIKA data sheet PE 81.85
Applications
■■ Food and beverage industry
■■ Pharmaceutical industry
■■ Filling and packing machinery
■■ Sanitary applications
Special features
■■ Easily-readable, robust display
■■ Intuitive and fast setup
■■ Easy and flexible mounting configurations
Pressure switch model PSA-31
Description
Award-winning in design and functionality Customised installation
The successful design and the excellent functionality of the The installation of the PSA-31 can be flexibly adapted to
WIKA switch family were already confirmed by winning the the individual mounting situation. Due to the almost unlim-
"iF product design award 2009" for the PSD-30 pressure ited rotation of the display and case by more than 300°,
switch. the display can be adjusted independently of the electrical
connection. The display can thus always be aligned to face
The robust LED display has been designed using 9 mm high
the operator, and the M12 x 1 connection positioned to suit
characters (the largest possible) and with a slight incline in
the desired cable routing.
order to make reading the level as easy as possible from a
long way off. A 14-segment display has been used, since it High quality
represents text very well. During development of the WIKA switch family a high value
was placed on a robust design and the selection of appropri-
The 3-key operation makes simple, intuitive menu navigation
ate materials suited to machine-building applications. For this
possible, with no need for additional assistance. The menu
reason the case and the threaded connection of the electri-
navigation is designed in accordance with the latest VDMA
cal connector are made from stainless steel. Overwinding or
standard. The VDMA standard for fluid sensors (24574-1,
tearing off the connector is therefore virtually impossible.
part 1 - pressure switches) has the aim of simplifying the use
of pressure switches by standardising menu navigation and
display.
The control keys have been designed as large as possible
and are arranged ergonomically to ensure fast and easy
adjustments. Operation without any additional assistance is
made easier through the tactile feedback.
WIKA data sheet PE 81.85 ∙ 05/2013 Page 1 of 6
Data sheets showing similar products:
WIKA adapter system; model 910.61; see data sheet AC 09.20
Pressure transmitter for sanitary applications; model SA-11; see data sheet PE 81.80
Electronic pressure switch with display; model PSD-30; see data sheet PE 81.67
Measuring ranges
Relative pressure
bar 0 ... 1 0 ... 1.6 0 ... 2.5 0 ... 4 0 ... 6 0 ... 10 0 ... 16 0 ... 25
psi 0 ... 15 0 ... 25 0 ... 30 1) 0 ... 50 0 ... 100 0 ... 160 0 ... 200 0 ... 300
Absolute pressure
bar 0 ... 1 0 ... 1.6 0 ... 2.5 0 ... 4 0 ... 6 0 ... 10 0 ... 16 0 ... 25
psi 0 ... 15 0 ... 25 0 ... 30 1) 0 ... 50 0 ... 100 0 ... 160 0 ... 200 0 ... 300
Vacuum and +/- measuring range
bar -1 ... 0 -1 ... +1.5 -1 ... +3 -1 ... +5 -1 ... +9 -1 ... +15 -1 ... +24
psi -14.5 ... 0 -14.5 ... +30 -14.5 ... +50 -14.5 ... +100 -14.5 ... +160 -14.5 ... +200 -14.5 ... +300
The given measuring ranges are also available in kg/cm2 and MPa.
Overpressure limit
2 times
Display Voltage supply
14-segment LED, red, 4-digit, 9 mm character size
Power supply
Display can be turned electronically through 180°
DC 15 ... 35 V
Update
Current consumption
100, 200, 500, 1,000 ms (adjustable)
maximum 100 mA
Total current consumption
Output signals max. 600 mA including switching current
Number of switching outputs: 1 or 2 max. 450 mA including switching current (with IO-Link option)
Type of switching output: PNP or NPN 1)
Analogue signal: 4 ... 20 mA or DC 0 ... 10 V
1) With the IO-Link option, switching output 1 is always PNP.
Reference conditions
Switching thresholds Temperature
Switch point 1 and switch point 2 are individually adjustable 15 ... 25 °C
Switching functions Atmospheric pressure
Normally open, normally closed, window, hysteresis 950 ... 1,050 mbar
Switching voltage Humidity
Power supply - 1 V 45 ... 75 % relative
Switching current Nominal position
■■ without IO-Link: max. 250 mA per switching output Process connection lower mount (LM)
■■ with IO-Link: max. 100 mA per switching output
Power supply
Settling time DC 24 V
Switching output: ≤ 10 ms
Analogue signal: 3 ms Load
see “output signals“
Zero offset adjustment
max. 3 % of span
Load
Analogue signal 4 ... 20 mA: ≤ 0.5 kΩ
Analogue signal DC 0 ... 10 V: > 10 kΩ
Page 2 of 6 WIKA data sheet PE 81.85 ∙ 05/2013
Accuracy data Operating conditions
Accuracy of the analogue signal Permissible temperature ranges
≤ ±1.0 % of span Ambient: -20 ... +80 °C
Storage: -20 ... +80 °C
Including non-linearity, hysteresis, zero offset and end value
Rated temperature range: 0 ... 80 °C
deviation (corresponds to measured error per IEC 61298-2).
Calibrated in vertical mounting position with process connec-
Medium temperature depending on the process
tion facing downwards.
connection
■■ G1 hygienic
Non-linearity
-20 ... +125 °C (+150 °C possible for up to 60 minutes)
≤ ±0.5 % of span BFSL (per IEC 61298-2)
■■ All other process connections
Adjustment accuracy of the switch points
-20 ... +100 °C (+135 °C possible for up to 60 minutes)
≤ ±0.5 % of span
Humidity
Display
45 ... 75 % relative
≤ ±1.0 % of span ±1 digit
Ingress protection
Long-term drift
IP 65 and IP 67
≤ ±0.2 % of span (per IEC 61298-2)
The stated ingress protection (per IEC 60529) only applies
Typical temperature coefficient of zero point when plugged in using mating connectors that have the
■■ Clamp DIN 32676, DN 32 appropriate ingress protection.
0 ... 20 °C: 0.75 % of span/10 K
20 ... 80 °C: 0.45 % of span/10 K Vibration resistance
10 g (IEC 60068-2-27, vibration under resonance)
■■ All other process connections
0 ... 20 °C: 0.7 % of span/10 K Shock resistance
20 ... 80 °C: 0.2 % of span/10 K 50 g (per IEC 60068-2-6, mechanical shock)
Typical temperature coefficient of span
All process connections
0 ... 80 °C: 0.1 % of span/10 K
Process connections
Designation Thread size
Hygienic G 1, flush 1) 2)
Grooved union nut DIN 11851 DN 40
with conical coupling 3) DN 50
Tri-clamp 1 ½"
2"
Clamp DIN 32676 DN 32
DN 40
DN 50
1) Sealing from EPDM or FKM
2) Suitable for WIKA adapter system model 910.61; see data sheet AC 09.20
3) For a 3-A conform connection of process connections with milk thread fittings per
DIN 11851, profile sealings from SKS Komponenten BV or Kieselmann GmbH have to be
used.
Other connections on request
WIKA data sheet PE 81.85 ∙ 05/2013 Page 3 of 6
Electrical connections CE conformity
Connections EMC directive
■■ Circular connector M12 x 1, 4-pin 2004/108/EC, EN 61326 emission (group 1, class B) and
■■ Circular connector M12 x 1, 5-pin 1) interference immunity (industrial application)
1) Only for version with two switching outputs and analogue signal
RoHS conformity
Electrical safety Yes
Overvoltage protection: DC 40 V
Short-circuit resistance: S+ / SP1 / SP2 vs. U-
Reverse polarity protection: U+ vs. U- Approvals
Insulation voltage: DC 500 V
■■ GOST-R, import certificate, Russia
Connection diagram ■■ 3-A, food, USA
Circular connector M12 x 1 (4-pin)
This instrument is 3-A marked based on a third party verifica-
U+ 1 tion for conformance to the 3-A standard 74-05.
4 3 U- 3
1 2 S+ 2
SP1 4 Certificates
■■ Material certificate per EN 10204-3.1
Circular connector M12 x 1 (5-pin)
■■ Confirmation of the class and indication accuracy
U+ 1 ■■ FDA conformity
U- 3 ■■ Manufacturer's declaration regarding EU regulation
S+ 5 1935/2004 EC
SP1 4
Others on request
SP2 2
Approvals and certificates, see website
Legend:
U+ Positive power supply
U- Negative power supply
S+ Analogue output
SP1 Switching output 1
SP2 Switching output 2
Materials
Wetted parts
Process connection:Stainless steel 1.4435 / 316L
Non-wetted parts
Case: Stainless steel 304
Keyboard TPE-E
Display window: PC
Display head: PC+ABS-Blend
Pressure transmission medium
KN 92 medicinal white mineral oil, FDA conform per
CFR 172.878 and 21 CFR 178.3620(a); conform to USP, EP
and JP
Page 4 of 6 WIKA data sheet PE 81.85 ∙ 05/2013
Dimensions in mm
Pressure switch
with clamp
Design Dimensions in mm
ØMb Ød ØD
DIN 32676 DN 32 29 43.5 50.5
DN 40 32 43.5 50.5
DN 50 40 56.6 64
Tri-clamp 1 ½" 32 43.5 50.5
2" 40 56.6 64
with grooved union nut DIN 11851
Design Dimensions in mm
Ød9 G ØD g h
DIN 11851 DN 40 56 Rd 65 x 1/6 78 10 20
DN 50 68.5 Rd 78 x 1/6 92 11 20
WIKA data sheet PE 81.85 ∙ 05/2013 Page 5 of 6
with G1 hygienic
O-ring, not
wetted
O-ring, wetted
For dimensions of the appropriate process adapters and welding sockets see data
sheet AC 09.20
Accessories and spare parts
Sealings for G1 hygienic, wetted
Dimensions: 21.82 x 3.53 mm
Material Colour Temperature range Conformity to Order no.
EPDM 70 black -40 ... +145 °C FDA 21 CFR 177.2600, USP XXV class VI and 3-A (18-03) 14004173
sanitary standards class 2 (max. 8 % milk fat)
FKM 75 black -15 ... +200 °C FDA 21 CFR 177.2600, USP XXIII class VI and 3-A (18-03) 14004174
sanitary standards class 1
Sealings for G1 hygienic, not wetted
Dimensions: 35 x 2.5 mm
Material Colour Temperature range Conformity to Order no.
EPDM 70 black -40 ... +145 °C - 14023833
Ordering information
Model / Measuring range / Number of switching outputs / Type of switching output / Analogue signal / Process connection /
Certificates
© 2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.
Page 6 of 6 WIKA data sheet PE 81.85 ∙ 05/2013
05/2013 GB
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Straße 30
63911 Klingenberg/Germany
Tel. (+49) 9372/132-0
Fax (+49) 9372/132-406
E-mail