LIEBERT® NXC from 80 to 200 kVA
Vertiv™
Vertiv designs, builds and services mission critical technologies that enable the vital applications for
data centers, communication networks, and commercial and industrial environments. We support
today's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure
management products, software and solutions, all complemented by our global service network.
Bringing together global reach and local knowledge, and our decades-long heritage including brands
like Chloride®, Liebert®, NetSure™ and Trellis™, our team of experts is ready to take on your most
complex challenges, creating solutions that keep your systems running—and your business moving.
Together, we’re building the future of a world where critical technologies always work.
YOUR VISION, OUR PASSION.
Vertiv.com
2
Liebert® NXC from 80 to 200 kVA
Continuous Reliability impact. Liebert NXC’s combination of
The Liebert® NXC 80 - 200 kVA range performance features, impressive FEATURES AND
offers reliable and flexible secure power integrated autonomy and compact PERFORMANCES
in a fully integrated package solution. Its footprint make it ideal for guaranteeing
highly efficient transformer-free double clean, continuous power for a wide range
of applications from IT and • Output power factor up to 1
conversion technology delivers
installation and running cost savings. manufacturing to retail and transport. • Double conversion efficiency up
With a rated output power factor up to 1, Its low THDi and active input power to 96%
Liebert NXC is also able to provide factor correction ensure that the current • ECO mode efficiency up to 99%
greater active power than a traditionally absorbed from the upstream distribution
network is near equal to its nominal • Input current total harmonic
rated 0.9 power factor UPS. Liebert NXC distortion correction (THDi) < 3%
achieves up to 96% efficiency in double output current, hence eliminating the
conversion mode and up to 99% in ECO need for oversizing gensets and other • Battery charger up to 50 A
mode, thus ensuring effective load equipment. • Integrated manual bypass
protection, while reducing the total cost
• Integrated input and output
of ownership (TCO) and environmental breakers/switches
97,0% • Integrated parallel load bus and
96,0% synchronization port (LBS)
95,0%
94,0%
93,0%
92,0%
91,0%
90,0%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Liebert NXC efficiency curve
3
LIEBERT® NXC from 80 to 200 kVA
Flexibility
VERTIV TRELLIS™
To ensure superior protection for critical loads, the Liebert® NXC range has been
designed to optimize specific rating requirements, thus enhancing flexibility and Vertiv Trellis™ platform is a
installation space needs. real-time infrastructure
optimization platform that enables
Liebert NXC’s flexibility is further enhanced through:
the unified management of data
• Integrated parallel and dual bus control center IT and facilities
• Common or distributed battery bank. infrastructure.
The Vertiv Trellis platform
software can manage capacity,
Full Galvanic Isolation track inventory, plan changes,
Liebert NXC offers integrated full galvanic isolation, meaning that an isolation visualize configurations, analyze
transformer may be housed inside the UPS cabinet. This greatly reduces the system and calculate energy usage, and
footprint, thus providing space saving advantages. optimize cooling and power
equipment as well as enable for
The transformer may be connected to the input or to the output of the UPS, virtualization.
providing: The Vertiv Trellis platform
• Full galvanic isolation for medical and other critical applications monitors the data center,
providing a thorough
• Installation with two independent input sources (with different neutrals) understanding of system
• Installation in distribution without neutral. dependencies to help IT and
facilities organizations keep the
data center running at peak
performance. This unified and
complete solution, delivers the
power to see the real situation in
your data center, make the right
decision and take action with
confidence.
In The Field
Parallel and Dual Bus Ready
Liebert NXC can be connected with up
to four units in parallel. A single unit can Automatic AC Bypass
be upgraded to parallel operation via
AC AC AC AC
easy to modify software settings, Normal Normal Normal Normal
allowing the system to be customized for
the requested configuration. The Loop
BUS connection used in paralleling the
system delivers ultimate reliability and
eliminates the possibility of a single
point of failure, ensuring perfect load
sharing and fast detection of any
variation in the system status.
Furthermore, the output of two single or
parallel Liebert NXC units can be Load
synchronized to deploy a dual bus feed,
achieving Tier IV level reliability.
Liebert NXC - Parallel configuration
4
Communication
Liebert® NXC features a multi-lingual Serviceability considerably minimizes the time needed
LCD user interface allowing close control The architecture of the Liebert NXC is for repairs and optimizes serviceability.
and monitoring of system status and designed to optimize installation and Liebert NXC also comes equipped with
performance. The UPS offers the simplify service with its easily removable casters to facilitate ease of movement
following communication features: power assembly. This architecture and relocation.
• Voltage-free contact ports
• USB interface
• Optocoupler based interfaces
• Intellislot for SNMP, Modbus or Relay
communication.
These communication capabilities make
Liebert NXC compatible with any
building management system.
Software Connectivity
Vertiv Multilink™ software prevents
unexpected server shutdowns and
minimizes downtime warning of pending
power losses and initiating safe shutdown
of operating systems if required. Vertiv
Nform™ network communications
system enables customers to leverage
the distributed monitoring capabilities of
network connected equipment,
providing centralized management of
distributed systems. Connectivity cards Liebert NXC - 80 - 120 kVA Liebert NXC - 160 - 200 kVA
Vertiv LIFE™ Services Remote Diagnostic and Preventive Monitoring
Vertiv's service program is designed to First Time Fix Rate Fast Incident Response
ensure that your critical power protection Pro-active monitoring and data Vertiv LIFE Services allow for immediate
system is maintained in an optimum measuring ensure that when our definition of the best course of action, as
state of readiness at all times. customer engineers are dispatched a result of the regular communication
The Vertiv LIFE™ Services remote on-site, they arrive prepared for first time between your Liebert NXC system and
diagnostic and preventive monitoring resolution. our Vertiv LIFE Services centers.
service provides early warning of UPS
conditions and out of tolerances. Proactive Analysis Reporting
This allows effective proactive
From Vertiv LIFE Services centers, our You will receive a comprehensive report
maintenance, fast incident response
experts proactively analyze the data and detailing the working order of your
and remote trouble shooting, giving
trends of your equipment, to recommend equipment and its operational
customers complete security
actions to ensure their best performance. performance.
and peace of mind.
With Vertiv LIFE Services you will benefit Minimized Total Cost of Ownership
from:
of Your Equipment
Uptime Assurance The continuous monitoring of all relevant
parameters in turn maximizes unit
Constant monitoring of UPS parameters,
performance, reduces on-site maintenance
thus maximizing the system’s availability.
and extends the life of your equipment.
5
LIEBERT® NXC from 80 to 200 kVA
Liebert® NXC Specifications
Technical Characteristics
Ratings (kVA) 80 100 120 160 200
INPUT
Nominal input voltage (V) 380/400/415
Input voltage range without battery discharge (V) 305 to 477
Nominal frequency (Hz) 50/60
Input frequency range (Hz) 40 to 70
Input power factor (kW/kVA) 0.99
Current THD at full linear load (THDI%) <3
Bypass voltage tolerance (%) selectable from +20 to -40
Bypass frequency tolerance (%) ±20 (±10 selectable)
BATTERY
Number battery cells per string Max: 264; Min: 180
Voltage temperature compensation (mV/°C/Cell) -3.0 (selectable from 0 to -5.0 around 25°C to 30°C, or inhibit)
Battery charger max. power (kW) 12 18 24 30
OUTPUT
Nominal output voltage (V) 380/400/415 (three-phase)
Nominal output frequency (Hz) 50/60
Nominal active power (kW) 80 100 120 160 200
THDv with 100% linear load (%) 2
Inverter overload capacity 105% with continuous operation; 125% for 10 min; 150 for 1min; >150% for 200ms
Double conversion efficiency 100% 95.7% 95.7% 95.6% 95.5% 95.3%
75% 95.9% 95.9% 95.8% 95.7% 95.7%
50% 95.9% 95.8% 95.9% 95.8% 95.8%
25% 95.0% 94.7% 95.0% 94.9% 94.9%
ECO mode efficiency (%) 99.0%
DIMENSIONS and weight
Dimensions (W x D x H) mm 600 x 1000 x1600 600 x 1000 x 2000
Weight (excluding battery) kg 285/313 337/365 475/525 520/570
Weight (including 32 batteries) kg N/A
GENERAL
Noise at 1 m (dBA) ≤59 ≤60 ≤60 ≤61 ≤62
Protection level IEC (60529) IP20
General and safety requirements for UPS EN/IEC/AS 62040-1
EMC requirements for UPS EN/IEC/AS 62040-2
UPS classification according to CEI EN 6240-3 VFI-SS-111
6
Customer Experience Center
Vertiv™ state-of-the-art Customer to 1.2 MVA of capacity. Testing includes Our Customer Experience Center offers
Experience Center located in individual modules, as well as complete three validation experiences:
Castel Guelfo (Bologna - Italy), power systems, with the added • Demo - carried out on new products
enables our customers to possibility of the customer’s switchgear to demonstrate UPS performance
experience first-hand a wide support systems being connected, thus • Standard - validation test showing
guaranteeing smooth, rapid installation UPS standard technical performances
variety of data center
and commissioning of large power in compliance with UPS catalogue and
technologies, supported by systems. IEC 62040-3 standards
constant consultation from R&D Testing is also customized based on the • Customized - session tailored to
and engineering specialists. complexity, size and number of UPS validating customer’s specific technical
components in the configuration. performance needs.
Customers visiting the center will be
able to witness pre-installation
demonstrations, covering the technical
performance, interoperability and
efficiency of Vertiv UPS systems under
real field conditions. These processes
can be experienced from the
facility’s control room, where real-time
performance measurements and
reporting will be available while providing
full visibility of the demonstration area.
The center can host simultaneous tests
at full load of up to 4000 A.
The customer validation area specifically
dedicated to UPS consists of four
testing stations, each one providing up