The ABB 4620 Series Conductivity Analyzer provides accurate and reliable measurement of conductivity across a wide range of applications, featuring advanced diagnostics and a universal transmitter. It supports ultra-pure water applications and includes options for temperature retransmission, with robust construction for harsh environments. The system is user-friendly, with multiple language support and easy installation, ensuring minimal maintenance and high performance.

Uploaded by

mohamed farah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views12 pages

SS 4620 8

The ABB 4620 Series Conductivity Analyzer provides accurate and reliable measurement of conductivity across a wide range of applications, featuring advanced diagnostics and a universal transmitter. It supports ultra-pure water applications and includes options for temperature retransmission, with robust construction for harsh environments. The system is user-friendly, with multiple language support and easy installation, ensuring minimal maintenance and high performance.

Uploaded by

mohamed farah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Data Sheet Conductivity Analyzer

SS/4620_8
Models 4620 & 4625

■ Comprehensive range of field-proven


conductivity cells
– satisfies broad range of applications.

■ Comprehensive diagnostics facility with in-built


software protection
– ensures security and confidence in operation.

■ Universal transmitter
– covers applications from ultra-pure water to liquids
with conductivity up to 10,000µS/cm.

■ Ultra-pure water temperature compensation


– ensures accuracy at conductivities below 1µS/cm.

■ Second current or Modbus option


– enables temperature to be retransmitted

■ IP66/NEMA4X
– reliable operation in demanding environments.

■ Guaranteed cell constant


– ensures high accuracy and total interchangeability.

■ English, French, German and Spanish


software
A high specification conductivity
– simple, user-selection of display language.
analyzer offering advanced
functionality, simple operation and
reliability in harsh environments
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

4620 Series Conductivity Analyzer Confidence in Service


The ABB 4620 Series conductivity analyzer comprises a To complement the well proven design and unrivalled accuracy
transmitter and a sensing system to accurately, and reliably, and reliability in service of the conductivity cells the entire
measure and transmit the conductivity value in a range of water sensing loop is regularly self monitored for short circuits and
monitoring applications. temperature element faults. The instrument includes non-volatile
memory eliminating the need for battery back-up and line
The 4620 Series analyzer offers high performance and
voltage supply filtering to minimize the effects of mains borne
advanced functionality in a compact cost effective package. It is
interference.
rugged and reliable for safe operation in harsh environments,
simple to install and use, and requires minimum maintenance.
Two Current Outputs
All 4620/25 Conductivity Analyzers can be supplied with an
Sensor System
additional current output to enable both the conductivity and
The sensor system can be selected to suit a specific application
temperature to be retransmitted.
from an extensive range of well proven conductivity cells. All cells
have guaranteed ±1% cell constant and Pt100 temperature Alternatively a Modbus serial communication can be supplied.
compensation elements. A variety of mounting configurations
Analog outputs configured for conductivity can be set by the
are offered to meet most industrial applications.
user as linear, bi-linear or logarithmic. Selecting linear provides
The cells are constructed in either epoxy resin with annular an output in direct proportion to the measuring range. Selecting
carbon electrodes, or stainless steel and are resistant to bi-linear or logarithmic enables excellent discrimination at low
polarization, requiring virtually no maintenance. conductivity levels, yet permits a readable output during high
level excursions.
The design and method of construction has resulted in a world
class product with an enviable reputation for long life, quality and
reliability.
100
90
% Retransmission Output

80
The 4600 Series Universal Transmitter 70
The 4600 series universal transmitter provides the operator 60
interface and communications to other devices. The signal from 50
the sensing system is converted by the transmitter and the 40
information is presented on a large custom designed, easy to 30
read, back-lit liquid crystal display (LCD) as a conductivity value 20
in one of seven programmable units of measure. 10

A process retransmission signal and two alarm relay outputs are 0


0 10 20 30 40 50 60 70 80 90 100 110%
provided as standard, while an optional RS485 serial interface Conductivity Measurement – shown as % of Display Span
allows the transmitter to be easily incorporated into the ABB
PC30 supervisory system. Bi-linear Output
Available in a wall mounted or 1⁄4 DIN panel mounted version the
transmitter is protected to IP66, ensuring reliable operation in 100
the most demanding situations. The same level of protection is
90
maintained during programming and calibration.
% Retransmission Output

80

70
User Friendly Operation 60
An easy to read display is used in conjunction with the four tactile 50
membrane key pads to prompt the user through the 40
programming procedures. Included as standard is a five 30
language software package, to display information in one of
20
English, French, German, Italian or Spanish languages.
10

0
0.1% 1% 10% 100%
Easy Installation, Commissioning and Maintenance Conductivity Measurement – shown as % of Display Span
Compact panel or wall mounting transmitter allows flexible and
easy installation. The unique LCD is easy to read in all light 3-decade Logarithmic Output
conditions. Used in conjunction with the membrane key pad it
simply prompts the user through the set up procedure. Range,
alarm levels, set point adjustments and system calibration are
easily set.

2
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

Specification – Transmitter

Display Power Supply


Measured value Voltage requirements
5-digit x 7-segment back-lit LCD 100 to 130V, 200 to 260V, 50/60Hz

Information Power consumption


16-character, single line, dot matrix, back-lit LCD < 6VA AC

Ranges Error due to power supply variation


Programmable 0 to 0.5µS/cm up to 10,000µS/cm Less than 0.1% for +6% –20% variation from nominal supply
(with various cell constants) voltage

Scaling Insulation
µS/cm, µS/m, mS/cm, mS/m, Mohm-cm, TDS and PPM Mains to earth (line to ground) 2kV RMS
Conductivity ranges configurable as linear, bi-linear,
2- or 3-decade logarithmic

Accuracy Outputs and Set Points


±1.0% f.s.d., ±1 digit No. of relays
Two
Linearity
±0.1% f.s.d. No. of set points
Two
Temperature measuring range
–10°C to 150°C (14° to 302°F). Set point adjustment
Programmable
Temperature compensation
–10°C to 130°C (14° to 266°F) automatic Set point hysteresis
±1% fixed
Temperature coefficient
Programmable 0 to 3.0%/°C (0 to 1.5%/°F) Local set point annunciation
Red l.e.d.
Temperature sensor
Pt100 resistance thermometer Relay contacts
Single pole changeover
Reference temperature
Rating 250V AC 250V DC max.
20°C (68°F) or 25°C (77°F) programmable
3A AC 3A DC max.
Loading (non-inductive) 750VA 30W max.
Environmental Data (inductive) 75VA 3W max.
Operating temperature limits
Insulation
–20° to 55°C (–4° to 131°F)
2kV RMS contacts to earth (ground)
Storage temperature limits
–25° to 55°C (–13° to 131°F)

Operating humidity limits


Up to 95% RH non-condensing

3
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

…Specification – Transmitter

Retransmission Mechanical Data


No. of retransmission signals Model 4620
One fully isolated – standard Wall-mounting
Two fully isolated – optional Protection IP66

Output current Dimensions 160mm (6.30 in.) wide x 214mm (8.43 in.) high
x 68mm (2.68 in.) deep
0 to 10mA, 0 to 20mA or 4 to 20mA programmable
Weight 2kg (41/2 lb)
Output ranges
Model 4625
Retransmission 1 Panel-mounting
Zero 0 fixed
Protection IP66 front
Span 10 to 100% of the display range
Dimensions 96mm (3.78 in.) wide x 96mm (3.78 in.) high
Retransmission 2 (optional) x 191mm (7.52 in.) deep
Programmable conductivity or temperature Weight 1.5kg (31/4 lb)
+0.8 +0.8
Conductivity as Retransmission 1 Panel cut-out: 92 –0
mm x 92 –0
mm
+0.03 +0.03
Temperature –10° to 150°C (14° to 302°F) (3.62–0 in. x 3.62–0 in.)
min. span 20°C (36°F)

Accuracy
±0.25% FSD ±0.5% reading

Resolution
0.1% at 10mA, 0.05% at 20mA

Max. load resistance


750Ω (20mA max.)

Serial communication
RS485 (optional extra)

4
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

Specification – Sensing System (Conductivity Cells)


Select the required model number from those listed below.

Dip Cell Model 2025 Specification Ordering Information


Cell constant Order under part number 2025–000
available 0.1 or 1.0 Cell constant K = 0.1 4
Cable
Length Type Dip type Cell constant K = 1.0 6
Dims. in mm (in.) 4.6 m (15 ft)
fittted Cell body Loaded epoxy resin
with Electrode matl. Carbon
bulkhead Non-temperature
Retaining plug and Fixing detail Adjustable with compensated 0
'O' Rings socket bracket provided Temperature
Maximum press. compensated Pt100 5
bar (psi) N/A
Adjustable 740 (29)
Mounting Maximum temp. 90°C (194°F)
Bracket

68 (2.6) 103 (4)


(Model (Model
2025–400 2025–600
Series) Series)
27 (1.06) dia.

Flow Cell Model 2045 Specification Ordering Information


Cell constant Order under part number 2045–000
available 0.1 or 1.0
Dims. in mm (in.) Cell constant K= 0.1 4
Quick release cover on Type Flow-line
Cell constant K = 1.0 6
watertight terminal box Cell body Loaded epoxy resin
Threaded 1/2 in. BSP 0
Electrode matl. Carbon
Threaded 1/2 in. NPT 8
Fixing detail Threaded
1
/2 in. BSP parallel Non-temperature
or NPT compensated 0
81 36
(3.18) (1.4) Maximum press. Temperature
bar (psi) 6.6 (100) compensated Pt100 5

Maximum temp. 100°C (212°F)


1/2 in. BSP
Parallel or NPT
25 (1) Thread
124
(4.88)
2 Fixing Screws
44 (1.73) Between
Centres

5
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

…Specification – Sensing System (Conductivity Cells)

Screw-in Model 2077 Specification Ordering Information


Cell constant Order under part number 2077–000
available 0.1 or 1.0
Cell constant K= 0.1 4
Dims. in mm (in.) Type Screw type
Cell constant K = 1.0 6
68 Cell body Loaded epoxy
(2.67) resin
Threaded 1 in. BSP 0
Electrode matl. Carbon
Threaded 1 in. NPT 8
70 (2.75) Fixing detail Threaded
1 in. BSP parallel
or NPT Non-temperature
22 (0.86)
Maximum press. compensated 0
bar (psi) 6.6 (100) Temperature
122 (4.8) Maximum temp. 100°C (212°F) compensated Pt100 5
(2077-600
Series)
87 (3.4) 1 in. BSP or
(2077-400 NPT Thread
Series)
27
(1.06) dia.

Screw-in Model 2078 Specification Ordering Information


Cell constant Order under part number 2078–000
available 0.05 or 0.1
915mm (36 in.) Cell constant K= 0.05 3
Dims. in mm (in.)
length of Type Screw-in
Cell constant K = 0.1 4
3 /4 in. BSP or connecting cable Cell body 316 St. Steel
fitted with
NPT Thread watertight
Electrode matl. 316 St. Steel
plug and socket Threaded 3/4 in. BSP
22 (0.86) dia. Fixing detail Threaded
3 fitted with plug & socket 0
/4 in. BSP parallel
or NPT Threaded 3/4 in. BSP 1
Maximum press. Threaded 3/4 in. NPT 7
19 (0.75) bar (psi) 10.5 (150) Threaded 3/4 in. NPT
Maximum temp. 110°C (230°F) fitted with plug & socket 8
B
A
Non-temperature
compensated 0
Model A mm (in) B mm (in)
Temperature
2078–4 184 (7.24) 102 (4.0) compensated Pt100 5
2078–3 184 (7.24) 102 (4.0)

6
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

Withdrawable Cell Model 2085 Specification Ordering Information


Cell constant Order under part number 2085–000
0.9m (36 in.) available 0.05 or 0.1
Dims. in mm (in.) Cell constant K = 0.05 3
Cable length
Type Withdrawable
with watertight Cell constant K = 0.1 4
Clearance plug and socket Cell body Naval brass and
for 130 (5.1) 316 St. Steel
Removal

Valve Closed
Non-temperature

178 (7)
Electrode matl. 316 St. Steel
compensated 0
Fixing detail Used with
Temperature
Model 2089 valve
compensated Pt100 5
assembly 11/2 in.
BSP parallel or NPT
140 (5.5)
Valve Open

Maximum press. Order withdrawable valve for this cell


bar (PSI) 10.5 (150) under part number 2089–800.
Maximum temp. 110°C (230°F)
25 (1)

11/2 in. BSPP 89 (3.5)

35
(1.38)

Model 2999
A range of stainless steel flow chambers is available for flow applications which require the
use of a screw-in type cell (e.g. ultrapure water applications). These are available as the
Dims in mm (in.) 2999 Series, the most common versions of which are detailed below. Special
requirements can be catered for under certain circumstances.
For Process Connections
see adjacent table
Ordering Information
Part No. Description Process Connections
2999-015 Flow jacket to fit Model 2078 cell 10mm tube connections
(23/4)
51(2)

3
2999-020 Flow jacket to fit Model 2078 cell /8 in. BSP parallel
70

3
2999-025 Flow jacket to fit Model 2073/76 cell /8 in. BSP parallel
2999-100 Flow jacket to fit Model 2271 cell 10mm tube connections
64(217/32) 2999-115 Flow jacket to fit Model 2072 cell 10mm tube connections
135 (55/16) 2999-190 Flow jacket to fit Model 2078 cell 3
/8 in. NPT

Note.
This is only a selection of flow chambers available. If your requirements are not listed
above, please contact our Sales Department stating your needs as fully as possible.

7
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

Electrical Connections

1 2 3 1 2 3
1 2 3 4 5 6 7 + – N L
4 5 6 4 5 6

Channel 1 Channel 2 Serial Retrans. Relay 1 Power


Relay 2 Supply

Earth Stud

Channel 1 Channel 2 Serial Retransmission Relay 1 Power


Relay 2 Supply
Conductivity Cell Temperature Compensator RS485 Output Relays Mains Supply
1 – Screen 5 – Brown 1– + Retrans. 1 – NC N – Neutral
2– 6 – Green/Yellow 2 – Rx+ output 2–C Relay 1 L – Line
3 – White 7 – Blue 3 – Rx– 3 – NO – Earth
Cell
4 – Black 4 – Tx+ 4 – NC
(0V) 5 – Tx– 5–C Relay 2 Earth
6 – 0V 6 – NO Stud
(Optional)

Model 4620 Wall-mounting Version using Cells Fitted with Bulkhead Plug and Socket*

Retransmission output Positive 1


13 0V
Negative 2
1 13
14 Rx– RS485 Serial
3
2 14 15 Rx+ Interface (Optional)
Normally Closed 4 3 15 16 Tx–
Relay 1 Common 5 4 16
17 Tx+
Normally Open 6 5 17
TB1 6 18
TB2 18 Blue
Normally Closed 7 7 19 19 Green/Yellow Temperature Compensator
Relay 2 Common 8 8 20
20 Brown
Normally Open 9 9 21
10 22 21 Black
Earth 10
Mains supply
11 23 22 White
Neutral 11 12 24 Conductivity Cell
23
Live 12
24 Screen

Model 4625 Panel-mounting Version using Cells Fitted with Bulkhead Plug and Socket*

* Note. When using cells supplied without bulkhead plug and socket connect as follows:
Model 4620 Yellow = terminal 5
Red = terminal 3
Green = terminal 6
Blue = terminal 7 – In addition connect screen to the earth stud and link terminals 6 and 7
Model 4625 Yellow = terminal 8
Red = terminal 22
Green = terminal 19
Blue = terminal 18 – In addition connect screen to the earth stud and link terminals 18 and 19
Note.
To select the most suitable cell constant for the desired working range use the following criteria:
Minimum range 10 x cell constant
Maximum range 10,000 x cell constant
e.g. cell constant k = 0.1 Minimum range = 10 x 0.1 = 1.00µS/cm
Maximum range = 10,000 x 0.1 = 1000µS/cm
For ultrapure water applications (less than 1.00µS/cm) a cell constant of 0.05 or 0.1 must be used.

8
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

Overall Dimensions

Dimensions in mm (in.)

160 (6.3) 68 (2.68)

250 214 232


(9.84) (8.43) (9.13)

69 (2.72)

Model 4620 Wall-mounting Version

9
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

…Overall Dimensions

Dimensions in mm (in.)

96 (3.78) 12 (0.47) 191 (7.52) 92 +0.8 +0.03


–0 (3.62 –0 )

96 92 +0.8
–0
Panel Cut-out (3.62 +0.03)
(3.78) –0

Model 4625 Panel-mounting Version

10
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

Ordering Information
To order a 4600 Conductivity Analyzer select the Transmitter, Sensing System and Connecting Cables from the following information.

Models 4620 & 4625 Conductivity Analyzers 462 X – X 0 0


Range 0 to 10,000µS/cm, power supply 110V/240V 50/60Hz, high and low alarms
Case
Wall-mounting IP66 0
Panel-mounting IP66 front 5
Output
Single isolated current output 5
Modbus serial data interface 7
Two isolated current outputs 8

Conductivity Cell
Select the appropriate Conductivity Cell – see pages 4 and 5.

Connection Cables
Cell connection cable part no. 0233-811
Temperature compensation connection cable part no. 0233-819
(Maximum length 100m (325ft) when using cell constants K = 0.1 and K =1.0 and 50m when using cell constant K = 0.05.)

The 4600 Series transmitters are so friendly and easy to program they are normally supplied with standard factory settings. If specific
programming requirements are stated at the time of ordering, units can be despatched suitably customized. Please apply to the
nearest ABB office for details.

11
Conductivity Analyzer
Models 4620 & 4625 SS/4620_8

ABB has Sales & Customer Support The Company’s policy is one of continuous product
expertise in over 100 countries worldwide improvement and the right is reserved to modify the
information contained herein without notice.
www.abb.com Printed in UK (05.04)
© ABB 2004
Issue 8
SS/4620

ABB Limited ABB Inc.


Oldends Lane, Stonehouse Analytical Instruments
Gloucestershire, GL10 3TA 9716 S. Virginia St., Ste. E
UK Reno, Nevada 89521
USA
Tel: +44 (0)1453 826661 Tel: +1 775 850 4800
Fax: +44 (0)1453 829671 Fax: +1 775 850 4808

You might also like