Usa Understanding Fiber Reinforced Concrete

The document provides an overview of fiber reinforced concrete (FRC), detailing fiber terminology, types, and performance characteristics. It outlines the classifications of fibers according to ASTM standards and emphasizes the importance of selecting the appropriate fiber type for specific applications. Additionally, it discusses the testing methods for assessing flexural strength and toughness of FRC, highlighting the need for third-party testing for impartial results.

Uploaded by

ebrahim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views5 pages

Usa Understanding Fiber Reinforced Concrete

The document provides an overview of fiber reinforced concrete (FRC), detailing fiber terminology, types, and performance characteristics. It outlines the classifications of fibers according to ASTM standards and emphasizes the importance of selecting the appropriate fiber type for specific applications. Additionally, it discusses the testing methods for assessing flexural strength and toughness of FRC, highlighting the need for third-party testing for impartial results.

Uploaded by

ebrahim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

UNDERSTANDING FIBER REINFORCED

CONCRETE

CONTENT

FIBER TERMINOLOGY 1
OVERVIEW 2
FIBER TYPE 2
FIBER PERFORMANCE 3
FLEXURAL TEST OF FIBER REINFORCED CONCRETE 4
FLEXURAL TOUGHNESS OF FIBER REINFORCED SHOTCRETE 5

FIBER TERMINOLOGY

Aspect Ratio | The ratio of the length to the diameter of one single Equivalent Flexural Ratio (Re3 or RDT,150) | The ratio of the
fiber. The diameter may be the actual or equivalent diameter, as equivalent flexural strength (fe3 or fDT,150) and the flexural strength
defined below. (modulus of rupture) of the concrete.

Crack | A complete or incomplete separation of concrete into two Fiber Count | Fiber concentration measured by the number of
or more parts produced by breaking or fracturing. fibers in a unit volume of concrete.

Collated Fibers | Fibers that are held together prior to the mixing Fiber Dosage Rate | The total fiber weight in a unit volume of
process by cross linking, by chemical or mechanical means. composite (generally expressed as kg/m3 or lb/yd3).

Denier | The weight (in grams) of 9,000 meters of a continuous Fiber Volume Fraction | The total fiber volume in a unit volume of
fiber filament. Irregular shaped fibers are measured through linear composite (generally expressed as a percentage).
density method, or denier analysis.
Fibrillated Fibers | A fiber configuration that has sections of the
Ductility | The ability of material to absorb energy and sustain fiber splitting to form fiber branches.
loads beyond a yield point that defines the limit of elastic behavior
(onset of cracking), i.e. as opposed to a brittle material that Flexural Strength | The maximum flexural tensile stress achieved
demonstrates abrupt loss of strength beyond the elastic range. in a beam test, also referred to as the modulus of rupture (MOR).

Equivalent Diameter of a Fiber | The diameter of a circle with an Limit of Proportionality (LOP) | The point at which a load-
deflection or stress-strain curve departs from the initial linear
area equal to the average cross-sectional area of the fiber.
response.

1/5 UNDERSTANDING FIBER REINFORCED CONCRETE 07/20 / 03.2786.18


UNDERSTANDING FIBER REINFORCED
CONCRETE
Mono-filament fibers | A single fiber, which may not be prismatic Toughness | The ability of fiber-reinforced concrete to sustain
in cross-section. loads after cracking of the concrete, i.e., energy absorption
capacity. It should be noted that, in connection with fiber concrete,
Equivalent Flexural Strength (fe3 or fDT,150) | The flexural residual toughness is to flexural toughness or toughness in bending.
strength retained by fiber reinforced concrete after cracking from
the ASTM C1609 beam testing.

OVERVIEW

Fiber reinforced concrete (FRC) is not a new concept. Since biblical times, fibers were used in cement-based construction materials in
the form of straw and horse hair. Today, there are a large variety of fiber options for reinforcing concrete available in the
marketplace. These include micro and macro synthetic fibers, steel, and blended fibers, which are defined below. With so many
options, it can be difficult to determine exactly what fiber is required for a given application. Examples of existing applications
utilizing FRC include ground supported slabs, composite metal deck, pile supported slabs, mat slabs, pavements, bridge decks,
tunnel segments, shotcrete, and various precast applications.

FIBER TYPE

The first step to choosing the right fiber is to understand the type of fiber required for your application. The main standard for fiber
reinforced concrete is ASTM C 1116.

ASTM C 1116, Standard Specification for Fiber Reinforced Concrete and Shotcrete, outlines four (4) classifications of fiber reinforced
concrete:

• Type I - Steel fiber reinforced concrete or shotcrete (ASTM A820)


• Type II - Glass fiber reinforced concrete or shotcrete (ASTM C1666)
• Type III - Synthetic fiber reinforced concrete or shotcrete (ASTM D7508,
polypropylene based only)
• Type IV - Natural fiber reinforced concrete or shotcrete (ASTM D7357)

Micro fibers (see Figure 1) have a diameter that is less than 0.3mm. Micro fibers
are either monofilament or fibrillated. Micro fibers should be used for plastic
shrinkage control (cracking that can occur in the first 24 hours of concrete cure),
impact protection, and fire explosive spalling protection. Micro fibers are not a
structural reinforcing fiber and cannot be used to replace any structural steel
elements, except the fibrillated micro fiber can be used to replace the lightest Figure 1 | Micro Fiber - Sika® Fibermesh®-150
gage wire fabric (6x6 W1.6/W1.6) in slabs on ground.

2/5 UNDERSTANDING FIBER REINFORCED CONCRETE 7/2020 / 03.2786.18


UNDERSTANDING FIBER REINFORCED
CONCRETE
Structural macro fibers (see Figure 2) can be steel or synthetic, have a diameter
greater than or equal to 0.3mm. Macro fibers can be used as a replacement of
mesh or rebar reinforcement in concrete or shotcrete. Macro fibers can resist
tensile stresses and control crack development. Macro fibers are used where an
increase in residual (post-cracking) flexural strength is required (ASTM C1609).

There are five types of steel fibers in ASTM A820:

• Type I - Cold Drawn Wire - Typically higher tensile strength due to drawing
process (SikaFiber® Novocon® CHE or HE Steel fibers)
• Type II - Cut sheet (SikaFiber® Novocon® CS1000)
• Type III - Melt extracted (Typically not available in marketplace)
• Type IV - Mill cut (Typically not available in marketplace)
• Type V - Modified cold drawn (SikaFiber® Novocon® XR)

There are also blends of micro and macro fibers (see Figure 3). The blends utilize
the crack control of both the micro and macro fibers. In short, fiber blends offer
control of cracking that can occur in the first 24 hours of concrete cure (micro fiber)
and long-term crack control due to loads (macro fibers).

Figure 2 | Macro Fiber - SikaFiber® Enduro® Prime

FIBER PERFORMANCE

Fiber performance is influenced by three characteristics: tensile strength, aspect


ratio (calculated as the length/diameter) and anchorage (hooked, crimp, emboss,
fibrillation, etc.). One characteristic does not outweigh another; all three items
must work together for optimal performance. Fiber reinforced concrete is a
composite material and therefore, all fibers are tested in the concrete to prove
their performance.

The higher the tensile strength of the fiber, the better the support structure. The
Figure 3- Blended Fibers - SikaFiber® Novomesh®-950anchorage ensures that the tensile strength of the fiber can be utilized. The
higher the aspect ratio, the higher performing the fiber. The longer the fiber
length, the more embedment of the fiber in the concrete. If the fiber is too long, it can be hard to mix. There is an optimal length for
every fiber. Finally, the smaller diameter means more fibers per pound (higher fiber count), which leads to the ability to obtain more
fibers over the crack.

3/5 UNDERSTANDING FIBER REINFORCED CONCRETE 7/2020 / 03.2786.18


UNDERSTANDING FIBER REINFORCED
CONCRETE
Steel fibers may be collated (glued) together in a clip (see Figure 4). Macro synthetic fibers may be wrapped or pucked together. The
collated or pucked fibers do not improve performance of the fiber reinforced
concrete. Collated fibers improve the ease of mixing of high aspect ratio fibers.
Collated or pucked fibers are added to the concrete mix and the bundles are spread
throughout the concrete. Continued mixing action breaks apart the clips or bundles
to let the individual fibers separate quickly throughout the mix.

Fibers begin to function in a structural supportive manner when the concrete


matrix starts to crack, just like traditional reinforcement. The crack has to occur for
the load to switch from the concrete to the reinforcement. Unlike reinforcing bars,
fibers are uniformly distributed in the concrete matrix; therefore, the distance
between the fibers is much smaller and can intercept the crack much quicker. The
Figure 4 | Collated Steel Fibers - SikaFiber®
fibers then produce ductility and support by bridging cracks and thus providing Novocon® CHE6560
post crack strength to the concrete.

FLEXURAL TEST OF FIBER REINFORCED CONCRETE

When specifying with fibers for concrete reinforcement, you should not think in terms
of dosage (pounds/cubic yard), but overall in toughness, also known as flexural
capacity. The toughness and the energy which could be absorbed by the addition of
fibers could be computed by determining the area under a stress-strain curve (from
flexural strength beam test - ASTM C1609).

The improved toughness from the addition of fibers is generated as the fibers gradually
slip out of the concrete matrix. It is thus preferred that pull-out of the fibers occurs
instead of fibers breaking. If the fibers break, bond strength (anchorage) between fibers
and the surrounding concrete matrix is too high. In order to achieve optimum efficiency
of the fibers, the bond strength between fibers and the concrete matrix needs to be as
close as possible to the same value as the tensile strength of the fibers, but still less.

The standard industry performance indicator for FRC is the RDT,150 (Re3) or fDT,150 (fe3)
value. Re3 and fe3 are measured with standard beam tests in a third point loading
arrangement per ASTM C1609 (see Figure 5, Standard Test Method for Flexural Figure 5 | ASTM C1609 Beam Test
Performance of Fiber Reinforced Concrete using beam with third point loading). ASTM
C1609 replaced ASTM C1018, which was withdrawn in 2006. The fe3 (equivalent flexural strength) is the average flexural stress to
deflect the beam up to 3mm after first crack. The Re3 (equivalent flexural strength ratio) is the ratio of the equivalent flexural
strength (area under the load deflection curve) and the flexural strength of the concrete. The Re3 or fe3 values can be used in
calculations per published guidelines; such as ACI 544 and ACI 360.

4/5 UNDERSTANDING FIBER REINFORCED CONCRETE 7/2020 / 03.2786.18


UNDERSTANDING FIBER REINFORCED
CONCRETE
The fiber supplier is typically asked, per the specifications, to present beam testing from third party certified testing facilities that
clearly demonstrate the performance criteria (fe3 or Re3) can be met. Third party beam performance testing is important.
Manufacturers should not supply beam testing from their own lab to ensure an impartial result.

FLEXURAL TOUGHNESS OF FIBER REINFORCED SHOTCRETE

Shotcrete Quality Control is measured via post crack energy absorption


testing (also called toughness) expressed in Joules. Toughness is tested
using the ASTM C1550 Standard Test Method for Flexural Toughness of
Fiber Reinforced Concrete (see Figure 6). The test was designed to
replicate the typical shotcrete loading conditions. Fiber suppliers should
supply documentation from third party testing facilities that their fiber
can meet the required joule specification using one of these tests.

Figure 6 | ASTM C1550 Shotcrete Round Panel Test

5/5 UNDERSTANDING FIBER REINFORCED CONCRETE 7/2020 / 03.2786.18