0% found this document useful (0 votes)
220 views310 pages

Copeland Alco Controls General Product Catalogue 2023 en GB 5288442

The 2024 product catalog from Copeland Europe GmbH provides a comprehensive overview of their refrigeration, air conditioning, and heat pump products, including various scroll and reciprocating compressors, refrigeration units, and controls. It emphasizes the importance of safety, accuracy in technical data, and the responsibility of users in product management, while also highlighting innovations for low GWP and natural refrigerants. The catalog serves as a resource for customers seeking sustainable solutions in compliance with evolving regulations.

Uploaded by

Hany Zakher
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
220 views310 pages

Copeland Alco Controls General Product Catalogue 2023 en GB 5288442

The 2024 product catalog from Copeland Europe GmbH provides a comprehensive overview of their refrigeration, air conditioning, and heat pump products, including various scroll and reciprocating compressors, refrigeration units, and controls. It emphasizes the importance of safety, accuracy in technical data, and the responsibility of users in product management, while also highlighting innovations for low GWP and natural refrigerants. The catalog serves as a resource for customers seeking sustainable solutions in compliance with evolving regulations.

Uploaded by

Hany Zakher
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 310

PRODUCT CATALOG

General product
catalogue 2024
For refrigeration, air conditioning, and heat pumps
Important safety advisory

Please be aware that the components listed in this catalogue are not designed for use with caustic, poisonous, or
flammable substances. Copeland Europe GmbH will not be responsible for any damage resulting from the use of these
substances with our products.

General information

The technical data in this catalogue has been carefully compiled, but we acknowledge that inaccuracies or
typographical errors may occur. The technical specifications are provided for your information only and should not be
seen as explicit guarantees or warranties about our products or services.

We regularly update technical data. If you need confirmation of specific details, please get in touch with Copeland
Europe GmbH directly, specifying the information you need.

Copeland Europe GmbH and its affiliated companies are not liable for any inaccuracies in the stated product
capacities, dimensions, or for any typographical errors. We reserve the right to modify products, specifications, designs,
and technical data without prior notice, and illustrations may not accurately represent final products.

Choosing, using, and maintaining any product is the purchaser’s and end-user’s responsibility. Copeland Europe
GmbH does not take responsibility for these aspects of product management.

The information provided is based on our reliable data and tests. It is intended for use by those with the necessary
technical skills, at their own risk. Our products are designed primarily for stationary use. If you plan to use our products
in mobile applications, it’s crucial to verify their suitability. This may require conducting specific tests, which should be
overseen by the plant manufacturer.

2
Scroll Compressors
- Comfort
• Copeland ZR scroll compressor range for R513A, R407C and R134a 12
• Copeland YP scroll compressor range for R32 16
• Copeland ZP scroll compressor range for R410A 18
• Copeland ZPD & ZRD digital scroll compressor ranges for R513A, R410A and R407C 22
• Copeland YPV variable speed scroll compressor ranges for R32 26
• Copeland XPV & ZPV variable speed scroll compressor ranges for R410A 28
• Copeland YH fixed speed scroll compressor range for A2L refrigerants R454C and R452B 30
• Copeland ZH fixed speed scroll compressor range for R410A and R407C 32
• Copeland YHV variable speed scroll compressor ranges for A2L refrigerants R452B and R454B 36
• Copeland XHV & ZHW variable speed scroll compressor ranges for R410A 38
• Copeland ZH scroll for heat recovery and high condensing applications for R134a 40
• Copeland ZRH(V) & YRH(V) horizontal scroll compressor ranges for R513A, R454C, R407C and R134a 42

- Refrigeration
• Copeland YB and YBD scroll compressor range for medium temperature refrigeration for 50
low GWP refrigerants classified as A2L
• Copeland ZB & ZBD scroll compressor ranges for medium temperature refrigeration 54
• Copeland YF, YFI and YFJ scroll compressor ranges for low temperature refrigeration 60
• Copeland ZF & ZFD scroll compressor ranges for low temperature refrigeration 64
• Copeland ZS, ZB & ZF*KA small scroll compressor range for low and medium temperature applications 72
• Copeland ZO & ZOD scroll compressor ranges for R744-subcritical refrigeration 74
• Sound shell for Copeland scroll compressors 76

Semi-Hermetic Reciprocating Compressors


- K and L reciprocating compressor range 80
- Discus™ reciprocating compressor range 86
- Copeland compressor electronics for Copeland Stream semi-hermetic compressors 92
- Copeland Stream with compressor electronics, semi-hermetic reciprocating compressors 94
- Copeland Stream digital with compressor electronics for continuous capacity modulation 100
- Copeland Stream compressors with compressor electronics for R744-transcritical applications 106
- Copeland Stream compressors with compressor electronics for R744-subcritical applications 110

Refrigeration Units
- Copeland large outdoor refrigeration units 114
- Copeland R744 Stream refrigeration units 118
- Copeland ZX outdoor refrigeration units for A2L refrigerants 120
- Copeland ZX outdoor refrigeration units with scroll compressors 124
- Copeland small ZX outdoor refrigeration units with scroll compressors 132
- Copeland ZX indoor refrigeration units with scroll compressors 134
- Copeland scroll indoor refrigeration units for refrigeration 136
- Copeland scroll digital receiver unit HLR 148
- Semi-hermetic refrigeration units K/L 154
- Refrigeration units with semi-hermetic Discus compressors 158
- Refrigeration units with semi-hermetic Stream compressors 162
- Compressor motor codes table 157

Controls*
- Electrical control valves 172
- Electronic controllers and sensors 184
- Thermo™- expansion valves 200
- Solenoid valves 224
- Mechanical pressure regulators 234
- Pressure controls and thermostats 240
- System protectors and moisture indicators 262
- Oil management components 282
- Suction accumulators and ball valves 294
- Appendix 300
- Controls keyword register 306
* Full range of A2L released products can be found in each chapter

3
4
Pioneering technologies for best-in-class products

Our 2024 product catalogue gives a comprehensive overview of Copeland compressors, refrigeration units and controls.
Take a look and discover our broad product ranges including these innovations:

• YPV scroll compressors for cooling-only and reversible systems up to 700kW for R32
• YH scroll compressors for low GWP refrigerant R452B
and R454C
• ZRH*KTR, ZRHV*KTR, YRH*KTE and YRHV*KTE horizontal scroll compressors for R513A, R454C, R407C and R134a,
for the specific needs of transport air conditioning.
• Scroll compressors for low GWP A2L refrigerants such as R455A, R454A, R454C, for medium temperature (YB, YBD), as
well as low temperature refrigeration (YF, YFI, YFJ)
• ZX outdoor refrigeration units for low GWP A2L refrigerants, with fix speed and digital capacity modulation, for medium
and low temperature applications

More in-depth technical data is available through our user-friendly Copeland selection software tool accessible via our web
page www.copeland.com/en-gb. For individual consultancy and service please contact your European sales office.

5
Supporting your transition to sustainable refrigerant solutions
The F-Gas regulation is one of the dominating challenges At Copeland, we don’t believe that “one refrigerant
of our industry today, posing new limitations to refrigerant fits all.” Our comprehensive portfolio of products and
choice and impacting system architecture. As the solutions designed for a variety of refrigerants enables
phasedown of HFCs continues globally, the challenge our customers to find the right fit for their architecture and
is to identify truly sustainable alternatives that maximize create efficient, F-Gas-compliant, future-proof systems.
the environmental, economic, and operational benefits.
Copeland’s broad portfolio of solutions includes natural Copeland offers the broadest selection of compressors
options such as CO2 (R744) and propane (R290), as well on the market, leveraging the use of multiple technologies
as HFO and HFO blends to address these needs. The pros and refrigerants — including natural and low-GWP options—
and cons of all options must be taken into consideration. to ensure end-users achieve the best seasonal efficiencies.

Solutions for low GWP A2L HFO refrigerants


Copeland offers long-term alternatives to system owners and contractors through our solutions with A2L refrigerants:
• Copeland compressors for cooling-only and reversible • YB and YBD standard and digital scroll compressors for
systems up to 700kW for R32. R32 is expected to medium temperature refrigeration, for R455A, R454A,
become the most used low GWP refrigerant to replace R454C
R410A in commercial air conditioning and heating in • YF, YFI and YFJ standard, EVI and digital scroll
Europe, thanks to its wide availability, performances, compressors for low temperature refrigeration, for
favorable cost and low charge. R455A, R454A, R454C
• Copeland ZX outdoor refrigeration units for A2L
• YH fixed speed scroll compressors for R454C and refrigerants, equipped with YB and YBD scroll compressors
R452B, for residential heating applications for medium temperature applications and with YF scroll
compressors for low temperature applications
• YHV variable speed scroll compressors for R452B and • A full range of controls and electronics, fully released for
R454B, for residential heating applications A2L refrigerants

Compared to previous systems with A1 refrigerants, systems with A2L refrigerants require additional system safety
measures because of their slight flammability. Copeland marks all compressors/units that are qualified for A2L refrigerants
with a sticker indicating the usage of flammable refrigerants. Therefore, for systems using such flammable refrigerants,
a dedicated risk assessment must be carried out by the user to ensure compliance with all applicable legislation and
regulations such as, but not limited to EN 378.

6
Solutions for natural refrigerants
R290 has zero ozone depletion potential, negligible global R744 is a leading option for environmental reasons, and it
warming potential, as well as excellent thermodynamic can be a winner for power consumption as developments
properties. It has long been known for its good of component technology and application methods
refrigerating performance, but also for its flammability continue to reveal potential performance gains. The
and, consequently, implies strict considerations for system pressures are much higher than in conventional
manufacturers in terms of system design and operation. systems, and all Copeland components are designed
R290 systems require in average half the charge of accordingly. Copeland offers a wide portfolio of innovative
hydrofluorocarbons (HFCs). Copeland offers R290 fixed products tailored for CO2 refrigeration systems. Please refer
speed and variable scroll compressors for refrigeration, to our separate CO2 Product Guide for more information.
heating and air conditioning, both in stationery and
transport applications. Please refer to our separate R290
Product Guides for more information.

EU HFC Phase Down Steps

100%
Percentage of baseline consumption allowed

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%
2015 2016 - 2018- 2021- 2024 2025- 2027- 2030 2031- 2033- 2036- 2039- 2042- 2045- 2048- 2050
2017 2020 2023 2026 2029 2032 2035 2038 2041 2044 2047 2049

2014 F-Gas regulation phasedown Note: The original 2015 base line changed in 2024 from 183
071 902 tons CO2 equivalent to the new base line of 176 700
2024 F-Gas regulation phasedown 479 tons CO2 equivalent.

7
Copeland scroll compressors

With the launch of scroll technology in the mid 1980s, give manufacturers, installers and end users the right
Copeland revolutionized the market setting new tools to reduce the carbon footprint of their installations,
standards in the air conditioning industry. Since then, optimize system design, efficiency, sound and reliability,
Copeland scroll has become the reference not only in air while ensuring long equipment lifetime and minimizing
conditioning but in refrigeration and heating applications capital and operating costs.
too. Thousands of customers trust our proprietary
technology: today, over 200 million Copeland scroll Applications for scroll compressors continue to grow
compressors are installed worldwide, more than any other thanks to innovation and adaptation. Industry as a whole
scroll compressor brand. Copeland scroll compressors has embraced its responsibility to put the environment
range from 1.5 to 40 hp and are designed to work with all first in its list of priorities, and this has led to strategic
the main refrigerants, including CO2. With compressors imperatives such as the need to introduce larger capacity
built in both vertical and horizontal versions and capable scrolls with improved seasonal performance, modulated
of digital modulation, Copeland has expanded the systems and products designed for use with low GWP
capability of scroll technology to new heights. refrigerants such as “natural” compounds (R744, R290),
R32 and HFO blends. Copeland is staying abreast of
Additional innovations such as Enhanced Vapor Injection, these challenges by successfully further developing its
variable speed scroll with drive technology for heat pump technologies in each of these areas.
compressors or the design of the Copeland sound shell

8
Copeland Mobile app: compressor
replacement at your fingertips

The Copeland Mobile app provides service technicians


with on-the-go access to Copeland’s database of product
information for Copeland compressors. The users now
have direct access to more than 3,000 models of (service)
compressors for air conditioning, heating and refrigeration
applications on their mobile phones.

Directly linked to Select Online software database, the app


helps find cross reference service replacements for the
searched compressor models and gives access to a large
network of official wholesalers, across Europe.

Copeland mobile app features:

• WebApp, linked to Select Online


• Model search/ Barcode scanning
• Replacement model cross-reference
• Auto-fill model recommendations
• Where to buy search
• Full parts, accessories and bill of materials listings
• Complete air conditioning, heating and refrigeration
compressor model information
• Metric unit conversion

The app is available in multiple languages and can be accessed both in desktop version and mobile via Apple
Store or Android Play Store.

Find more details about our mobile apps at: https://copeland.com/en-gb/tools-resources/mobile-apps

9
Comfort applications

GPC-EN-2024 COMFORT APPLICATIONS 10


Comfort applications

For decades, Copeland has driven advancement in the variable speed ranges for commercial comfort, we offer
air conditioning and heat pump industry, leading the field alternatives with a lower global warming potential for the
with engineering products and systems that maximize same applications. Increasingly stringent regulations, like
the comfort of office and living spaces – while minimizing F-Gas, are leading the shift towards low GWP refrigerants
costs and inefficiencies. in conjunction with the requirements for maximizing the
energy efficiency and driving the HVACR market towards
Copeland scroll compressors are designed to deliver more sustainable choices. Browse this catalogue to find
the highest performance in residential and commercial out more about our compressors for R454C and R452B ,
applications. Thanks to the widest selection of scroll suitable for heat pumps, plus the R32-optimized range for
compressors optimized for air conditioning and heating, chillers, reversible units, precision cooling systems and
it has never been easier to match all desired applications rooftops.
with the highest efficiency and reliability. The capacity
of our single scrolls ranges from 1.5 to 40hp and they We have extended our range of horizontal scroll
can reach an overall capacity of 180 hp per circuit compressors for transport air conditioning applications to
when combined in even and uneven tandems and include natural and low-GWP options. Their design and
trios. Whether your need is a cooling optimized, heating modulation capabilities are well suited for the needs of
optimized or reversible unit, you will find the most the passenger transport market.
advanced technology within our range.

One of the most important recent innovations for comfort


applications has been the introduction of variable
speed technology. It was first introduced with the ZHW
compressors (featuring Enhanced Vapor Injection),
as a solution for residential heat pump applications.
In addition to the R410A ZHW and XHV ranges for
residential applications, and the R410A XPV and ZPV

11 GPC-EN-2024 COMFORT APPLICATIONS


Copeland ZR scroll compressor range for R513A, R407C and R134a
ZR Copeland scroll compressor were developed or comfort and process/precision cooling applications
using R513A, R407C and R134a.

Applied in the air conditioning and comfort industry for water chillers, rooftops and close control unit
applications, scroll compressors are now the most used compression technology replacing reciprocating
and screw compressors due to its undeniable superiority. Several, fully Copeland qualified, multiple
compressor assemblies (tandem and trio) are available to allow the use of Copeland scroll compressors
into large capacity systems (ex. up to 500kW air cooled chillers) able to deliver optimal comfort, low
operating cost with higher seasonal efficiency (SEER). To support the new market needs of customers,
Copeland offers scroll compressors for R513A, a low-pressure refrigerant with a low GWP of 631. These
ranges are able to reach 5K superheat which allows better system performance optimization and cost.

The range of products goes from the ZR24 (2hp) to the ZR380 (30hp) for R407C and R134a and from
ZR24KRE (2hp) to ZR190KRE (15hp) for R513A, R407C and R134a.
ZR scroll compressor
ZR scroll compressor line-up R407C
Single ZR (1Ph)

Single ZR (3Ph)

kW Cooling
0 10 20 30 40 50 60 70 80 90

Tandem

Trio

kW Cooling
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K

ZR scroll compressor line-up R513A


Single ZR (3Ph)

Single ZR (1Ph)

kW Cooling
0 5 10 15 20 25 30 35

Tandem
kW Cooling
0 5 10 15 20 25 30 35 40 45 50 55

Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K

Features and benefits Operating envelope R407C


70
• Copeland scroll axial and radial compliance for superior
65
reliability and efficiency
• Wide scroll line-up for R407C, R134a and R513A
Condensing temperature °C

60
• Low TEWI (Total Equivalent Warming Impact)
55
• Low sound and vibration level
• Low oil circulation rate 50
• Copeland qualified tandem and trio configurations for
45
superior seasonal efficiency (SEER)
40

Maximum allowable pressure (PS) 35

30
• ZR24 to ZR81:
25
Low side PS 21 bar(g) / High side PS 29 bar(g)
• ZR108 to ZR380: 20
Low side PS 20 bar(g) / High side PS 32 bar(g) -30 -25 -20 -15 -10 -5 0 5 10 15 20 25
Evaporating temperature °C
R407C - 10K Superheat
ZR 24-92 ZR 144
ZR 94-190 ZR 250-380
GPC-EN-2024 COMFORT APPLICATIONS 12
Operating envelope R513A
90

80

70
Condensing Temperature °C

60

50
ZR108-190KRE, 10K
40
ZR24-92KRE, 10K
30

20

10

0
-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45
Evaporating Temperature °C

Technical overview ZR*KRE


R407C Capacity

Stub Discharge

Maximum
Oil Quantity (l)
Capacity (kW)

Displacement
R513A/R134a

Stub Suction

Motor Locked Rotor Sound


Nominal hp

Length/
Net Version/Code Operating Current (A) Pressure
(m3/h)

(inch)

(inch)

Width/
(kW)

Models EER Weight Current (A)


Height @1 m
(kg)
(mm) (dBA) ***
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**

ZR24KRE 2.0 3.5 5.0 3.0 5.9 3/4 1/2 0.7 239/245/364 25 PFJ TFD 13 5 58 26 54
ZR28KRE 2.5 4.2 5.9 2.9 6.8 3/4 1/2 1.1 239/245/364 26 PFJ TFD 13 5 61 32 57
ZR36KRE 3.0 5.2 7.6 3.1 8.6 3/4 1/2 1.2 239/245/387 27 PFJ TFD 16 6 82 40 55
ZR42KRE 3.5 6.2 8.9 3.2 10.0 3/4 1/2 1.1 239/245/400 28 PFJ TFD 20 7 97 46 56
ZR48KRE 4.0 6.9 10.3 3.1 11.4 7/8 1/2 1.5 239/245/417 29 PFJ TFD 24 10 114 50 57
ZR61KRE 5.0 9.0 13.0 3.2 14.4 7/8 1/2 1.9 246/257/438 38 TFD 13 66 58
ZR69KRE 5.5 10.2 14.3 3.2 16.2 7/8 1/2 1.9 246/257/438 43 PFJ 36 150 59
ZR72KRE 6.0 10.6 15.4 3.4 17.1 7/8 1/2 1.9 246/257/438 39 TFD 13 74 61
ZR81KRE 6.5 11.6 16.6 3.2 18.8 7/8 3/4 1.8 246/257/443 39 TFD 14 101 61
ZR92KRE 8.0 13.5 18.8 3.2 21.4 7/8 3/4 1.9 246/257/443 44 TFD 16 102 65
ZR108KRE 9.0 15.6 23.0 3.2 24.9 1 3/8 7/8 3.4 281/284/533 60 TFD 18 111 63
ZR125KRE 10.0 18.2 27.0 3.3 29.1 1 3/8 7/8 3.4 281/284/533 61 TFD 20 118 63
ZR144KRE 12.0 20.5 30.9 3.2 33.2 1 3/8 7/8 3.3 281/284/533 61 TFD 22 118 64
ZR160KRE 13.0 22.8 33.4 3.1 36.4 1 3/8 7/8 3.3 281/284/552 65 TFD 28 140 68
ZR190KRE 15.0 27.2 39.3 3.1 43.3 1 3/8 7/8 3.4 281/285/552 66 TFD 35 174 71
Conditions EN12900 : Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K ** 3 Ph: 380-420V/ 50Hz
* 1 Ph: 230V/ 50Hz *** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Technical overview ZR*KCE


R407C Capacity

Motor Maximum
Stub Discharge

Oil Quantity (l)


Displacement

Locked Rotor
Stub Suction
Nominal hp

Length/ Version/ Operating Sound


Net Current (A)
(m3/h)

(inch)

(inch)

Width/ Code Current (A) Pressure


(kW)

EER

Models Weight
Height @1 m
(kg)
(mm) 3 Ph** 3 Ph** 3 Ph** (dBA) ***

ZR108KCE 9.0 23.0 3.4 25.0 1 3/8 7/8 3.3 281/285/533 60 TFD 18 111 63
ZR125KCE 10.0 27.0 3.4 29.1 1 3/8 7/8 3.3 264/285/533 61 TFD 20 118 63
ZR144KCE 12.0 30.9 3.4 33.2 1 /8
3
7/8 3.3 281/285/533 61 TFD 22 118 64
ZR160KCE 13.0 33.4 3.2 36.4 1 /8
3
7/8 3.4 281/285/552 65 TFD 28 140 67
ZR190KCE 15.0 39.3 3.2 43.3 1 3/8 7/8 3.4 281/285/552 66 TFD 35 174 69
ZR250KCE 20.0 52.2 3.2 56.6 1 /8
5
1 /8
3
4.7 427/376/726 139 TWD 42 225 72
ZR310KCE 25.0 65.0 3.2 71.4 1 /8
5
1 /8
3
6.8 447/390/724 160 TWD 52 272 74
ZR380KCE 30.0 80.1 3.4 87.5 1 /8
5
1 /8
3
6.3 447/427/724 177 TWD 63 310 77
Conditions EN12900 : Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K *** @ 1m: sound pressure level at 1m distance from the compressor, free field condition
** 3 Ph: 380-420V/ 50Hz Models ZR22K3E-ZR48K3E, ZR61KSE and ZR61KCE-ZR81KCE are available as service compressors

13 GPC-EN-2024 COMFORT APPLICATIONS


Capacity data
Condensing Temperature 50°C
Cooling Capacity (kW) Power Input (kW)
R513A R513A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15
ZR24KRE 1.3 1.7 2.2 2.8 3.5 4.4 5.3 ZR24KRE 1.3 1.3 1.2 1.2 1.2 1.2 1.2
ZR28KRE 1.6 2.1 2.7 3.4 4.2 5.1 6.2 ZR28KRE 1.4 1.4 1.4 1.4 1.4 1.4 1.4
ZR36KRE 2.1 2.7 3.4 4.2 5.2 6.4 7.8 ZR36KRE 1.8 1.8 1.7 1.7 1.7 1.7 1.7
ZR42KRE 2.4 3.1 4.0 5.0 6.2 7.5 9.1 ZR42KRE 2.0 2.0 2.0 2.0 2.0 2.0 2.0
ZR48KRE 2.8 3.6 4.5 5.6 6.9 8.5 10.3 ZR48KRE 2.3 2.3 2.3 2.3 2.3 2.3 2.3
ZR61KRE 3.5 4.6 5.9 7.3 9.0 11.0 13.2 ZR61KRE 2.9 2.9 2.9 2.8 2.8 2.8 2.9
ZR69KRE** 4.0 5.2 6.6 8.2 10.2 12.4 14.9 ZR69KRE** 3.2 3.2 3.2 3.2 3.2 3.2 3.2
ZR72KRE 4.2 5.4 6.9 8.6 10.6 12.9 15.5 ZR72KRE 3.3 3.3 3.2 3.2 3.2 3.2 3.22
ZR81KRE 4.8 6.1 7.6 9.4 11.6 14.2 17.1 ZR81KRE 3.8 3.8 3.8 3.7 3.7 3.7 3.7
ZR92KRE 5.7 7.1 8.9 11.0 13.5 16.4 19.8 ZR92KRE 3.8 3.9 4.0 4.1 4.2 4.4 4.5
ZR108KRE 6.3 7.7 10.0 12.6 15.6 19.1 23.1 ZR108KRE 4.8 4.8 4.9 4.9 4.9 5.0 5.0
ZR125KRE 6.8 9.0 11.7 14.7 18.2 22.3 27.0 ZR125KRE 5.5 5.7 5.7 5.7 5.8 5.8 5.9
ZR144KRE 8.2 10.3 13.2 16.6 20.5 25.1 30.4 ZR144KRE 6.4 6.4 6.4 6.4 6.5 6.5 6.6
ZR160KRE 8.0 11.5 14.8 18.5 22.8 27.9 33.8 ZR160KRE 7.2 7.3 7.3 7.4 7.4 7.5 7.5
ZR190KRE 10.1 13.7 17.6 22.0 27.2 33.2 40.2 ZR190KRE 9.0 8.7 8.7 8.7 8.8 8.9 9.0
Conditions: Suction Superheat 10K / Subcooling 0K
** Single Phase only
Preliminary data

Condensing Temperature 50°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15
ZR108KCE 8.1 10.3 12.8 15.7 19.1 23.0 ZR108KCE 4.6 4.6 4.7 4.7 4.7 4.7
ZR125KCE 9.1 11.8 14.8 18.3 22.3 26.9 ZR125KCE 5.3 5.4 5.4 5.4 5.5 5.5
ZR144KCE 11.2 14.3 17.5 21.0 24.8 29.0 ZR144KCE 6.1 6.3 6.3 6.3 6.3 6.4
ZR160KCE 11.1 14.5 18.3 22.7 27.8 33.6 ZR160KCE 6.8 6.9 6.9 7.0 7.0 7.2
ZR190KCE 13.6 17.5 22.0 27.2 33.1 40.1 ZR190KCE 8.5 8.5 8.6 8.6 8.6 8.7
ZR250KCE 18.4 23.2 28.9 35.5 43.3 52.2 ZR250KCE 10.9 10.9 11.0 11.1 11.2 11.4
ZR310KCE 22.3 28.3 35.2 43.3 52.8 63.7 ZR310KCE 13.3 13.5 13.6 13.7 13.9 14.1
Conditions: Suction Superheat 10K / Subcooling 0K

Condensing Temperature +50°C


Cooling Capacity (kW) Power Input (kW)
R407C R407C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15
ZR24KRE 2.6 3.3 4.1 5.0 6.1 7.3 ZR24KRE 1.8 1.8 1.7 1.7 1.7 1.7
ZR28KRE 3.0 3.8 4.8 5.9 7.2 8.6 ZR28KRE 2.0 2.0 2.0 2.0 1.9 1.9
ZR36KRE 4.0 5.0 6.2 7.6 9.2 11.0 ZR36KRE 2.4 2.4 2.4 2.4 2.4 2.4
ZR42KRE 4.6 5.9 7.3 8.9 10.8 12.8 ZR42KRE 2.9 2.9 2.8 2.8 2.8 2.8
ZR48KRE 5.4 6.8 8.4 10.3 12.5 14.9 ZR48KRE 3.2 3.2 3.2 3.2 3.1 3.1
ZR61KRE 7.1 8.8 10.8 13.0 15.6 18.7 ZR61KRE 4.0 4.0 4.0 4.1 4.1 4.1
ZR69KRE** 7.8 9.6 11.8 14.3 17.3 20.6 ZR69KRE** 4.9 4.8 4.7 4.5 4.3 4.1
ZR72KRE 8.0 10.1 12.5 15.4 18.6 22.2 ZR72KRE 4.7 4.7 4.7 4.7 4.7 4.7
ZR81KRE 8.2 10.6 13.3 16.6 20.3 24.6 ZR81KRE 5.3 5.3 5.3 5.3 5.3 5.4
ZR92KRE 9.6 12.2 15.2 18.8 22.9 27.6 ZR92KRE 6.0 6.1 6.2 6.2 6.2 6.2
ZR108KCE/KRE 12.2 15.3 18.9 23.0 27.9 33.4 ZR108KCE/KRE 6.8 6.8 6.9 6.9 6.9 6.9
ZR125KCE/KRE 14.0 17.7 22.0 27.0 32.6 39.1 ZR125KCE/KRE 8.0 8.0 8.0 8.1 8.1 8.1
ZR144KCE/KRE 20.1 25.2 30.9 37.4 44.8 ZR144KCE/KRE 9.1 9.1 9.1 9.1 9.2
ZR160KCE/KRE 15.9 20.8 26.7 33.4 41.3 50.3 ZR160KCE/KRE 10.3 10.3 10.3 10.3 10.4 10.4
ZR190KCE/KRE 19.8 25.5 31.9 39.3 47.7 57.3 ZR190KCE/KRE 12.2 12.3 12.3 12.3 12.4 12.5
ZR250KCE 27.5 34.5 42.7 52.2 63.2 75.8 ZR250KCE 15.9 16.0 16.1 16.3 16.4 16.6
ZR310KCE 33.5 42.4 52.8 65.0 79.1 95.4 ZR310KCE 20.0 20.0 20.0 20.2 20.4 20.6
ZR380KCE 40.1 51.8 64.9 80.1 97.6 118.0 ZR380KCE 23.9 24.1 24.3 24.4 24.6 24.9
Conditions: Suction Superheat 10K / Subcooling 0K

GPC-EN-2024 COMFORT APPLICATIONS 14


ZR*KRE tandem model overview
Cooling Capacity (kW)
Model Tandem Assembly
R407C R513A R134a
Even Tandem
ZRT 48 KRE 2 x ZR24 KRE 10.0 7.0 7.2
ZRT 56 KRE 2 x ZR28 KRE 11.8 8.4 8.3
ZRT 72 KRE 2 x ZR36 KRE 15.2 10.4 10.5
ZRT 84 KRE 2 x ZR42 KRE 17.7 12.4 12.1
ZRT 96 KRE 2 x ZR48KRE 20.6 13.8 13.2
ZRT 122 KRE 2 x ZR61KRE 26.0 18.0 17.5
ZRT 144 KRE 2 x ZR72KRE 30.7 21.2 21.0
ZRT 162 KRE 2 x ZR81KRE 33.1 23.2 23.6
ZRT 184 KRE 2 x ZR92KRE 37.5 27.0 26.7
ZRT 216 KRE 2 x ZR108KRE 45.3 31.6 31.3
ZRT 250 KRE 2 x ZR125KRE 53.2 36.8 36.5
ZRT 288 KRE 2 x ZR144KRE 60.9 41.6 42.0
ZRT 320 KRE 2 x ZR160KRE 65.8 45.8 45.4
ZRT 380 KRE 2 x ZR190KRE 77.4 54.8 54.3
Conditions EN 12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K
Tandem Assemblies by System Manufacturers. Copeland can provide full technical support.
Preliminary data

ZR*KCE tandem model overview


Cooling Capacity (kW)
Model Tandem Assembly
R407C R134a
Even Tandem
ZRT 216 KCE 2 x ZR108KCE 46.0 31.3
ZRT 250 KCE 2 x ZR125KCE 54.0 36.5
ZRT 288 KCE 2 x ZR144KCE 61.8 42.0
ZRT 320 KCE 2 x ZR160KCE 66.8 45.4
ZRT 380 KCE 2 x ZR190KCE 78.6 54.4
ZRT 500 KCE 2 x ZR250KCE 104.0 71.0
ZRT 620 KCE 2 x ZR310KCE 130.0 84.4
ZRT 760 KCE 2 x ZR380KCE 163.0 110.8
Uneven Tandem
ZRU 315 KCE ZR125KCE + ZR190KCE 66.3 45.5
ZRU 350 KCE ZR160KCE + ZR190KCE 72.7 49.9
ZRU 440 KCE ZR190KCE + ZR250KCE 91.5 62.7
ZRU 500 KCE ZR190KCE + ZR310KCE 99.8 69.4
ZRU 560 KCE ZR250KCE + ZR310KCE 112.7 77.7
ZRU 690 KCE ZR310KCE + ZR380KCE 140.6 97.6
Conditions EN 12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K
Tandem Assemblies by System Manufacturers. Copeland can provide full technical support.

15 GPC-EN-2024 COMFORT APPLICATIONS


Copeland YP scroll compressor range for R32

Copeland YP compressors are designed for R32. Thanks to advanced


Copeland technologies, they reach the same field of application as
equivalent Copeland scroll compressors with R410A. This is achieved
without liquid injection or economizer. A dedicated scroll set minimizes
the discharge temperature caused by the high heat of compression of the
R32 refrigerant. R32 has a GWP of 675 and has been used for many years
as main ingredient of R410A and is widely available.

YP compressors can be used for cooling only systems, as well as for


reversible systems up to 700kW.

YP Copeland scroll compressor

YP scroll compressor line-up R32

Trio
Tandem
Single

Cooling
capacity (kW) 0 50 100 150 200 250 300 350

Features and benefits Operating envelope R32


70
• Designed for R32 65
• Wide operating envelope
60
• Low leak discharge check valve
Condensing temperature (°C)

55
• High part load efficiency thanks to a
variable compression ratio valve 50
• IP 54 terminal box 45
• Leak free hermetic design
40
• Tandem and trio capabilities
• Axial and radial compliance 35

• Copeland integrated solution ready 30

25
Maximum allowable pressure (PS)
20

15
• YP137, YP154 and YP182 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25
Low side PS 30.4 bar(g) / High Side PS 49 bar(g) Evaporating temperature (°C)
• YP83 to YP122, YP154, YP385 and YP485
Low side PS 30.4 bar(g) / High Side PS 50 bar(g) 5K superheat Active variable compression ratio
valve - higher efficiency

GPC-EN-2024 COMFORT APPLICATIONS 16


Technical overview

Stub Discharge
Capacity (kW)
Maximum

Oil Quantity
Motor Locked Rotor

hp - TonR*
Length/

Nominal
Operating

Cooling
Stub Net

(inch)
Width/ PED Version/ Code Current (A)
Models COP Suction Weight Current (A)

(l)
Height Category
(inch) (kg)
(mm)
3 Ph** 3 Ph** 3 Ph**

YP83K1T 7 18.8 3.2 7/8 3/4 1.8 253/258/443 2 43 TFD 14 83


YP91K1T 8 20.1 3.1 7/8 3/4 1.8 258/263/443 2 41 TFD 16 92
YP104K1T 9 23.4 3.3 1 1/8 7/8 2.5 259/270/559 2 48 TFD 18 128
YP122K1T 10 27.1 3.3 1 1/8 7/8 2.5 259/270/559 2 49 TFD 21 139
YP137K1T 12 30.4 3.2 1 3/8 7/8 3.3 271/285/551 3 68 TFD 24 147
YP154K1T 13 34.8 3.3 1 3/8 7/8 3.3 271/285/551 3 67 TFD 26 141
YP182K1T 15 40.6 3.3 1 3/8 7/8 3.3 271/285/551 3 68 TFD 31 186
YP233K1T 20 52.1 3.3 2 1/4 1 1/8 4.4 402/407/692 3 92 TED 35 240
YP293K1T 25 65.1 3.3 2 1/4 1 1/8 4.4 402/317/692 3 92 TED 45 287
YP385K1T 30 84.1 3.3 1 5/8 1 3/8 6.3 459/423/715 3 177 TED 81 343
YP485K1T 40 108.0 3.4 1 5/8 1 3/8 6.3 459/423/746 3 190 TED 111 536
Conditions EN12900 R32: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K
TonR* : Ton of refrigeration at 60Hz
** 3 Ph: 380-420V/ 50Hz

Capacity data
Condensing Temperature +50°C
Cooling Capacity (kW) Power Input (kW)
R32 R32
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15
YP83K1T 13.1 15.8 18.8 22.2 26.0 YP83K1T 5.8 5.8 5.9 5.9 5.9
YP91K1T 13.9 16.8 20.1 23.9 28.2 YP91K1T 6.3 6.4 6.5 6.5 6.4
YP104K1T 16.2 19.5 23.4 27.8 32.8 YP104K1T 7.0 7.1 7.1 7.1 7.0
YP122K1T 18.9 22.7 27.1 32.1 37.8 YP122K1T 8.1 8.2 8.2 8.2 8.2
YP137K1T 21.2 25.5 30.4 36.1 42.5 YP137K1T 9.5 9.6 9.6 9.6 9.5
YP154K1T 24.3 29.2 34.8 41.2 48.4 YP154K1T 10.4 10.6 10.7 10.6 10.4
YP182K1T 28.4 34.1 40.6 48.0 56.4 YP182K1T 12.3 12.4 12.5 12.5 12.4
YP233K1T 36.8 43.9 52.1 61.4 72.0 YP233K1T 15.0 15.3 15.6 15.8 16.0
YP293K1T 45.9 54.9 65.1 76.8 90.0 YP293K1T 18.8 19.2 19.5 19.8 20.0
YP385K1T 59.6 71.0 84.1 99.7 118.5 YP385K1T 25.2 25.3 25.4 25.5 25.5
YP485K1T 75.7 90.8 108.0 128.0 150.0 YP485K1T 31.4 31.8 32.2 32.6 33.0
Conditions: Suction Superheat 10K / Subcooling 0K

Tandem model overview

Cooling Cooling
Model Tandem Assembly Capacity Model Tandem Assembly Capacity
(kW) (kW)

Even Tandem YPT Uneven Tandem YPU


YPT 166 K 2 x YP 83 K1T 38 YPU 291 K YP137 K1T + YP154 K1T 65
YPT 182 K 2 x YP 91 K1T 40 YPU 336 K YP154 K1T + YP182 K1T 75
YPT 208 K 2 x YP 104 K1T 47 YPU 415 K YP182 K1T + YP233 K1T 93
YPT 244x K 2 x YP 122 K1T 54 YPU 526 K YP233 K1T + YP293 K1T 117
YPT 274 K 2 x YP 137 K1T 61 YPU 678 K YP293 K1T + YP385 K1T 149
YPT 308 K 2 x YP 154 K1T 70 YPU 870 K YP385 K1T + YP485 K1T 192
YPT 464 K 2 x YP 182 K1T 81
Conditions EN 12900: Evaporating 5°C, Condensing 50°C,
YPT 446 K 2 x YP 233 K1T 104 Superheat 10K, Subcooling 0K
YPT 586 K 2 x YP 293 K1T 130 Tandem assemblies by system manufacturers.
Copeland can provide full technical support.
YPT 770 K 2 x YP 385 K1T 168
YPT 970 K 2 x YP 485 K1T 216

17 GPC-EN-2024 COMFORT APPLICATIONS


Copeland ZP scroll compressor range for R410A

ZP Copeland scroll compressors, for R410A, for comfort and process


precision cooling applications. Copeland has been the pioneer in
launching the first complete line-up of R410A commercial scroll
compressors.

ZP Copeland scroll compressors are perfectly suitable for air-cooled


chiller systems up to 600kW (730 kW if water-cooled) featuring high
comfort and superior seasonal efficiency (SEER / SEPR / SCOP).
Whether used in stand-alone, tandem or trio configurations, the broad
ZP Copeland scroll line-up meets today’s market requirements with
unmatched flexibility, efficiency and proven reliability.

ZP104, ZP122 and ZP143KCE compressors for light commercial systems


have a reduced footprint and weight for more compact systems. Their
high efficiency helps to reduce operating costs.

ZP scroll compressor

ZP scroll compressor line-up

ZP (1Ph)

ZP (3Ph)

kW Cooling
0 10 20 30 40 50 60 70 80 90 100 110 120 140 160

Tandem

Trio

kW Cooling
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480

Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K

Features and benefits Operating envelope R410A


70
• Copeland qualified tandem and trio (now also uneven
configurations for superior seasonal efficiency
(SEER / SEPR / SCOP)
Condensing Temperature °C

60
• Copeland scroll axial and radial compliance for
superior reliability and efficiency
• Extended 5K operating envelope suitable for
50
heat pump applications
• Low TEWI (Total equivalent warming impact)
• Wide scroll line-up for R410A 40
• Low sound and vibration level
• Low oil circulation rate
30
Maximum allowable pressure (PS)
• ZP24 to ZP91: 20
Low side PS 29.5 bar(g) / High side PS 45 bar(g) -25 -20 -15 -10 -5 0 5 10 15 20
• ZP104 to ZP485:
Evaporating Temperature °C
Low side PS 29.5 bar(g) / High side PS 45 bar(g) 10K Superheat
ZP 24-31 ZP 36-143 ZP 154-485

GPC-EN-2024 COMFORT APPLICATIONS 18


Technical overview

Maximum

Stub Discharge
Displacement

Stub Suction
Motor Locked Rotor

Oil Quantity
Nominal hp
Length/ Operating Sound

Capacity
Net Version/ Code Current (A)

(m3/h)

(inch)

(inch)
Width/ Pressure

(kW)
Current (A)
Models EER Weight

(l)
Height @1 m
(kg)
(mm) 1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph** (dBA) ***

ZP24K5E 1.9 5.1 2.8 4.0 3/4 1/2 0.7 236/236/387 22 PFJ TFD 13 5 60 28 55
ZP29K5E 2.2 6.0 2.8 4.8 3/4 1/2 0.7 246/246/387 23 PFJ TFD 16 6 67 38 55
ZP31K5E 3.0 6.5 2.8 5.1 3/4 1/2 0.7 243/243/388 22 PFJ TFD 17 7 67 38 55
ZP36K5E 2.6 7.6 2.9 6.0 7/8 1/2 1.2 243/243/506 32 PFJ TFD 20 7 87 46 57
ZP42K5E 3.5 8.9 2.9 6.9 7/8 1/2 1.2 246/246/418 31 PFJ TFD 21 8 98 43 57
ZP54K5E 4.6 11.5 3.0 8.9 7/8 1/2 1.2 246/246/418 34 PFJ TFD 31 10 128 52 59
ZP61K5E 5.0 13.4 3.0 10.0 7/8 1/2 1.2 246/246/445 35 TFD 11 67 57
ZP72KCE 6.0 15.3 3.0 11.7 7/8 1/2 1.7 246/246/455 45 TFD 15 75 59
ZP83KCE 7.0 17.7 3.1 13.5 7/8 1/2 1.8 246/246/443 40 TFD 15 101 61
ZP91KCE 7.5 19.3 3.1 14.7 1 1/4 1 11/4 1.8 243/248/443 41 TFD 16 101 61
ZP104KCE 9.0 22.7 3.2 16.8 1 /8
1
7/8 2.5 297/262/559 49 TFD 18 128 60
ZP122KCE 10.0 26.5 3.2 19.6 1 1/8 7/8 2.5 297/262/559 49 TFD 22 139 61
ZP143KCE 12.0 31.6 3.2 23.1 1 /8
1
7/8 2.8 270/262/559 49 TFD 25 146 61
ZP154KCE 13.0 33.1 3.2 24.9 1 3/8 7/8 3.3 281/285/552 65 TFD 31 140 66
ZP182KCE 15.0 39.0 3.2 29.1 1 /8
3
7/8 3.3 281/285/552 66 TFD 34 174 66
ZP233KZE 20.0 50.6 3.3 36.6 1 5/8 1 1/8 4.4 315/315/661 92 TED 38 241 72
ZP293KZE 25.0 63.3 3.3 45.7 1 5/8 1 1/8 4.4 315/315/661 92 TED 49 288 72
ZP385KCE 30.0 82.4 3.2 60.8 1 /8
5
1 3/8 6.3 448/392/715 178 TWD 65 310 74
ZP485KCE 40.0 105.0 3.2 77.3 1 5/8 1 3/8 6.3 368/345/756 190 TWD 83 408 78
Conditions EN12900 : Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K
* 1 Ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data
Condensing Temperature +50°C
Cooling Capacity (kW) Power Input (kW)
R410A R410A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15
ZP24K5E 2.7 3.4 4.2 5.0 6.0 ZP24K5E 1.9 1.9 1.8 1.8 1.8
ZP29K5E 3.1 4.0 4.9 6.0 7.3 ZP29K5E 2.3 2.2 2.2 2.2 2.1
ZP31K5E 3.2 4.2 5.3 6.5 7.9 ZP31K5E 2.4 2.4 2.4 2.3 2.3
ZP36K5E 4.1 5.1 6.3 7.6 9.1 10.8 ZP36K5E 2.8 2.7 2.7 2.6 2.6 2.5
ZP42K5E 4.5 5.8 7.3 8.9 10.7 12.8 ZP42K5E 3.3 3.2 3.1 3.0 3.0 2.9
ZP54K5E 5.8 7.5 9.3 11.5 13.9 16.6 ZP54K5E 4.0 3.9 3.9 3.8 3.8 3.8
ZP61K5E 7.2 9.0 11.1 13.4 16.0 18.9 ZP61K5E 4.6 4.5 4.5 4.4 4.4 4.4
ZP72KCE 8.6 10.5 12.7 15.3 18.2 21.5 ZP72KCE 5.1 5.1 5.1 5.1 5.1 5.1
ZP83KCE 9.8 12.1 14.7 17.7 21.1 25.1 ZP83KCE 5.7 5.8 5.8 5.8 5.8 5.9
ZP91KCE 10.6 13.2 16.1 19.3 22.9 27.0 ZP91KCE 6.1 6.1 6.1 6.2 6.2 6.2
ZP104KCE 12.6 15.6 18.9 22.7 27.0 31.9 ZP104KCE 7.1 7.1 7.1 7.1 7.1 7.1
ZP122KCE 14.8 18.3 22.1 26.5 31.5 37.2 ZP122KCE 8.3 8.3 8.3 8.3 8.3 8.4
ZP143KCE 17.1 21.4 26.3 31.6 37.6 44.1 ZP143KCE 9.8 9.8 9.8 9.8 9.8 9.8
ZP154KCE 18.7 23.0 27.7 33.1 39.3 46.3 ZP154KCE 10.3 10.3 10.4 10.5 10.6 10.7
ZP182KCE 22.2 27.1 32.7 39.0 46.2 54.6 ZP182KCE 12.0 12.1 12.2 12.3 12.4 12.5
ZP233KZE 28.5 34.9 42.2 50.6 60.1 70.8 ZP233KZE 15.2 15.3 15.3 15.3 15.3 15.3
ZP293KZE 36.1 44.0 53.1 63.3 74.8 87.6 ZP293KZE 19.4 19.5 19.4 19.4 19.3 19.3
ZP385KCE 46.3 56.6 68.6 82.3 98.1 116.0 ZP385KCE 25.4 25.3 25.4 25.6 25.9 26.3
ZP485KCE 60.2 73.1 88.0 105.0 125.0 147.0 ZP485KCE 31.1 31.5 32.0 32.5 33.2 34.0
Conditions: Suction Superheat 10K / Subcooling 0K

19 GPC-EN-2024 COMFORT APPLICATIONS


Tandem model overview

Nominal Cooling Capacity Even Uneven


Model
hp (kW) Tandem Tandem

Tandem ZPT - Tandem Uneven ZPU

ZPT 72 K5E 2x3 16 •

ZPT 84 K5E 2 x 3.5 18 •

ZPT 108 K5E 2x4 23 •

ZPT 122 K5E 2x5 26 •

ZPT 144 KCE 2x6 31 •

ZPT 166 KCE 2 x 6.5 35 •

ZPT 182 KCE 2x8 39 •

ZPT 208 KCE 2x9 45 •

ZPT 244 KCE 2 x 10 53 •

ZPT 286 KCE 2 x 12 63 •

ZPT 308KCE 2 x 13 67 •

ZPU 336 KCE 13 + 15 73 •

ZPT 364 KCE 2 x 15 79 •

ZPU 417 K 15 + 20 90 •

ZPT 466 KZE 2 x 20 101 •

ZPU 477 K 15 + 25 103 •

ZPU 530 KZE 20 + 25 114 •

ZPT 586 KZE 2 x 25 125 •

ZPU 680 K 25 + 30 146 •

ZPT 770 KCE 2 x 30 165 •

ZPU 870 KCE 30 + 40 187 •

ZPT 970 KCE 2 x 40 209 •


System using ZP235 or ZP295 (20 or 25 hp) shall use ZP233KZE and ZP293KZE
Conditions EN 12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K
Tandem assemblies by system manufacturers. Copeland can provide full technical support.

GPC-EN-2024 COMFORT APPLICATIONS 20


21 GPC-EN-2024 COMFORT APPLICATIONS
Copeland ZPD & ZRD digital scroll compressor ranges
for R513A, R410A and R407C
Stepless capacity modulation in air conditioning applications:
flexible solution for R513A, R407C and R410A.

In many cooling and heating systems, the load and the operating
conditions vary over a wide range thus requiring the use of capacity
modulation. Digital scroll assures stepless modulation down to
10% of the nominal capacity, enabling precise temperature control, ZPD & ZRD
scroll digital compressor
superior comfort and energy saving.

Digital scroll compressors are the preferred choice for process


cooling, refrigeration racks, refrigeration units, VRF, rooftop and air
handling unit systems.

ZPD digital scroll compressor line-up R410A

ZPD (3Ph)

Tandem

kW Cooling
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

ZRD digital scroll compressor line-up R407C

ZRD (3Ph)

Tandem
kW Cooling
5 10 15 20 25 30 35

Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K

ZRD*KRE digital scroll compressor line-up R513A

ZRD*KRE (3Ph)
Tandem

kW Cooling
5 10 15 20 25

Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K

Features and benefits Maximum allowable pressure (PS)

• Wide modulation range from 10% to 100% for immediate • Digital ZRD42 to ZRD81:
load adjustment, close temperature comfort, Low Side PS 20 bar(g) / High Side PS 29.5 bar(g)
optimal comfort • Digital ZRD94 to ZRD125:
• No complex electronics, a quasi-drop-in solution for fast time Low Side PS 20 bar(g) / High Side PS 32 bar(g)
to market, no EMI/EMC problems, easy installation • Digital ZPD42 to ZPD91:
and maintenance Low Side PS 28 bar(g) / High Side PS 43 bar(g)
• No impact on system mechanical balance: no vibration and • Digital ZPD103 to ZPD182:
resonance phenomenon, no frame / piping Low Side PS 29.5 bar(g) / High Side PS 45 bar(g)
redesign necessary

GPC-EN-2024 COMFORT APPLICATIONS 22


Operating envelope

ZPD - R410A ZRD - R407C


70 70

65 65
Condensing Temperature °C

Condensing Temperature °C
60 60

55 55

50 50

45 45

40 40

35 35

30 30

25 25

20 20
-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25

Evaporating Temperature °C Evaporating Temperature °C


10K Superheat 10K Superheat
ZPD 34-91 ZPD 104-182 ZRD 125

ZRD - R513A
90

80
Condensing Temperature °C

70

60

50

40

30

20

10

0
-30 -25 -20 -15 -10 -5 0 5 10 15 20 25
Evaporating Temperature °C
10K Superheat

23 GPC-EN-2024 COMFORT APPLICATIONS


Technical overview - ZPD R410A models
Motor Maximum Locked

Stub Discharge
Displacement
Sound

Stub Suction

Oil Quantity
Length/ Version/ Operating Rotor

Capacity
Nominal
Net Pressure

(m3/h)

(inch)

(inch)
Width/ Code Current (A) Current (A)

(kW)

EER
hp
Models Weight @1 m -

(l)
Height
(kg) dB(A)
(mm)
3 Ph* 3 Ph* 3 Ph* **

ZPD61KCE 5.0 13.2 3.0 10.1 7/8 1/2 1.9 241/246/484 41 TFD 12 64 63

ZPD72KCE 5.0 15.3 2.9 11.6 7/8 1/2 1.9 241/246/484 40 TFD 15 75 67

ZPD83KCE 6.5 17.7 3.0 13.5 7/8 1/2 1.8 246/253/481 40 TFD 16 101 64

ZPD91KCE 8.0 19.2 3.1 14.7 7/8 3/4 1.8 246/253/481 40 TFD 16 101 69

ZPD104KCE 9.0 22.7 3.1 16.7 1 1/8 7/8 2.5 270/262/605 61 TFD 18 128 63

ZPD122KCE 10.0 26.3 3.1 19.7 1 1/8 7/8 2.5 270/262/605 62 TFD 21 139 63

ZPD137KCE 12.0 29.4 3.1 22.1 1 3/8 7/8 3.3 293/285/533 62 TFD 25 118 63

ZPD154KCE 13.0 33.1 3.1 24.9 1 3/8 7/8 3.3 314/285/552 65 TFD 27 140 66

ZPD182KCE 15.0 39.0 3.1 29.1 1 3/8 7/8 3.3 314/285/552 67 TFD 34 173 68

Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K


* 3 Ph: 380-420V/ 50Hz
** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Technical overview - ZRD*KRE R407C, R134a and R513A models


Discharge (inch)

Maximum

Pressure @1 m
Capacity (kW)

Capacity (kW)

Displacement
R513A/R134a

Motor Locked Rotor


Stub Suction

Oil Quantity
Nominal hp

Net Weight

Length/ Operating

(dBA) ***
Version/ Code Current (A)
R407C

Sound
(m3/h)

(inch)

Width/ Current (A)


Stub
EER

(kg)

Models
(l)

Height
(mm) 1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**

ZRD36KRE 3.0 5.2 7.7 3.2 8.3 3/4 1/2 1.2 239/244/435 30 PFJ TFD 17 7 97 40 57

ZRD48KRE 4.0 7.0 10.3 3.1 11.4 7/8 1/2 1.4 239/244/466 30 TFD 10 48 64

ZRD61KRE 5.0 8.9 12.4 3.2 14.4 7/8 1/2 1.9 246/257/481 38 TFD 11 64 65

ZRD72KRE 6.0 10.6 15.4 3.1 17.1 7/8 1/2 1.9 246/257/481 40 TFD 12 74 63

ZRD92KRE 8.0 13.4 18.8 3.1 21.4 7/8 3/4 1.9 246/257/481 43 TFD 16 102 64
Conditions EN12900 : Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K
* 1 Ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition
Preliminary data

Technical overview - ZRD*KCE R407C models


Motor Maximum Locked
Stub Discharge
Displacement

Sound
Stub Suction

Oil Quantity

Length/ Version/ Operating Rotor


Capacity
Nominal

Net Pressure
(m3/h)

(inch)

(inch)

Width/ Code Current (A) Current (A)


(kW)

EER
hp

Models weight @1 m -
(l)

Height
(kg) dB(A)
(mm) 3 Ph* 3 Ph* 3 Ph* **

ZRD125KCE 11.0 27.6 3.3 28.8 1 3/8 7/8 3.3 293/285/533 62 TFD 20 118 64
Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K
* 3 Ph: 380-420V/50Hz
**@1m: sound pressure level at 1m distance from the compressor, free field condition

GPC-EN-2024 COMFORT APPLICATIONS 24


Capacity data
Condensing Temperature 50°C

Cooling Capacity (kW) Power Input (kW)


R410A R410A
Evaporating Temperature (°C) Evaporating Temperature (°C)

Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15

ZPD61KCE 7.3 9.0 10.9 13.2 15.7 ZPD61KCE 4.2 4.3 4.4 4.4 4.5

ZPD72KCE 8.6 10.5 12.7 15.2 18.1 ZPD72KCE 4.9 5.0 5.1 5.2 5.2

ZPD83KCE 9.8 12.1 14.7 17.7 21.1 ZPD83KCE 5.9 6.0 6.0 6.0 6.0

ZPD91KCE 10.6 13.2 16.0 19.2 22.8 ZPD91KCE 6.2 6.2 6.2 6.3 6.3

ZPD104KCE 13.0 15.8 19.0 22.7 26.9 ZPD104KCE 7.0 7.0 7.1 7.2 7.3

ZPD122KCE 15.1 18.3 22.0 26.3 31.2 ZPD122KCE 8.0 8.1 8.2 8.3 8.4

ZPD137KCE 16.0 20.0 24.4 29.4 35.1 ZPD137KCE 9.6 9.5 9.4 9.4 9.3

ZPD154KCE 18.7 23.0 27.7 33.1 39.2 46.3 ZPD154KCE 10.3 10.3 10.4 10.5 10.6 10.7

ZPD182KCE 23.2 27.9 33.1 39.0 45.8 53.7 ZPD182KCE 12.2 12.3 12.4 12.5 12.6 12.7

Conditions: Suction Superheat 10K / Subcooling 0K

Condensing Temperature 50°C

Cooling Capacity (kW) Power Input (kW)


R513A / R513A /
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)

Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15

ZRD36KRE 2.1 2.7 3.4 4.3 5.2 6.3 7.5 ZRD36KRE 1.5 1.5 1.6 1.6 1.6 1.6 1.6

ZRD48KRE 2.9 3.7 4.6 5.7 7.0 8.5 10.2 ZRD48KRE 2.3 2.3 2.3 2.3 2.2 2.2 2.3

ZRD61KRE 3.6 4.6 5.8 7.2 8.9 10.8 13.1 ZRD61KRE 2.5 2.6 2.6 2.7 2.8 2.9 2.9

ZRD72KRE 4.3 5.6 7.0 8.7 10.6 12.9 15.5 ZRD72KRE 2.9 3.0 3.1 3.3 3.4 3.5 3.7

ZRD92KRE 5.4 6.9 8.7 10.9 13.4 16.3 19.6 ZRD92KRE 3.7 3.9 4.0 4.2 4.3 4.4 4.4
Conditions: Suction Superheat 10K / Subcooling 0K For capacity data for R450A please refer to Copeland Select Software
Preliminary data

Condensing Temperature 50°C


Cooling Capacity (kW) Power Input (kW)
R407C R407C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15
ZRD36KRE 4.1 5.2 6.3 7.7 9.2 ZRD36KRE 2.3 2.4 2.4 2.4 2.4
ZRD48KRE 5.4 6.8 8.4 10.3 12.5 ZRD48KRE 3.2 3.2 3.2 3.2 3.1
ZRD61KRE 6.3 8.0 10.0 12.4 15.1 ZRD61KRE 3.9 4.0 4.0 4.0 4.0
ZRD72KRE 8.0 10.1 12.5 15.4 18.6 ZRD72KRE 4.7 4.7 4.7 4.7 4.7
ZRD92KRE 9.6 12.2 15.2 18.8 22.9 ZRD92KRE 6.0 6.1 6.2 6.2 6.2
ZRD125KCE 14.3 18.1 22.5 27.6 33.3 39.4 ZRD125KCE 8.2 8.3 8.4 8.4 8.6 8.7

Conditions: Suction Superheat 10K / Subcooling 0K

25 GPC-EN-2024 COMFORT APPLICATIONS


Copeland YPV variable speed scroll
compressor range for R32 with drive
Copeland YPV variable speed compressors are designed for R32, a widely
available refrigerant with a GWP of 675. These scroll compressors deliver
maximum efficiency and superior performances to comply or exceed the
most stringent EcoDesign directive targets. Thanks to advanced Copeland
technologies, YPV compressors reach the same field of application as
equivalent Copeland scroll compressors with R410A.

The outstanding efficiency of YPV across different load- and operating


conditions reflects in a lower total lifecycle cost of the system, in diverse
applications such as commercial comfort - with hydronic cooling, reversible
units or rooftops - industrial chillers or close control units.
Copeland YPV variable speed scroll
compressor and drive

YPV variable speed scroll compressor line-up R32

YPV096 single

YPV066 single

YPV038 single

YPV030 single

YPV096 +
fixed speed tandems

YPV066 +
fixed speed tandems

kW cooling capacity
0 10 20 30 40 50 60 70 80 90 100 110 120 130

Features and benefits Maximum allowable pressure (PS)


• Designed for R32 • YPV066 – 096:
• Wide operating envelope for cooling and heating Low side PS 30.4 bar(g) / High Side PS 50.0 bar(g)
• Outstanding efficiency, thanks to variable speed
high performance motors and to Copeland variable
compression ratio valve
• Capability to tandemize YPV066-096 models with YP
fixed speed scrolls for maximum flexibility in system
design - no need for an oil separator
• Low leak discharge check valve
• Axial and radial compliance
• Copeland integrated solution ready

GPC-EN-2024 COMFORT APPLICATIONS 26


Operating envelope

YPV066/096 - R32 YPV030/038 - R32


70 70

65 65

60 60
Condensing temperature (°C)

55 55

Condensing temperature (°C)


50 50

45 45

40 40

35 35

30 30

25 25

20 20

15 15

10 10

5 5 30
-35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25
Evaporating temperature (°C) Evaporating temperature (°C)

5K superheat Active variable compression ratio


valve - higher efficiency

* The operating envelope may vary depending on the compressor speed. Please refer to the Copeland Select software

Technical overview
Compressor

Cooling Capacity (kW) Stub Stub Oil


Length/ Width/Height PED Net Weight
Models EER* Suction Discharge Quantity
Min Max Nominal (mm) Category (kg)
(inch) (inch) (l)

YPV030LT 2.9 19.3 16.0 3.1 3/4 1/2 1.2 196/207/376 2 18

YPV038LT 3.5 24.6 20.4 3.1 3/4 1/2 1.2 196/207/376 2 20

YPV0661T 9.1 42.0 35.6 3.2 1 1/4 7/8 2.5 273/262/559 3 41

YPV0961T 14.1 62.7 53.1 3.2 1 1/8 7/8 2.5 268/246/559 3 45


*Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K, 6000 rpm

Drive**

Matched Power Input (kW) Amps (A) Net Weight 3Ph Depth/Width/
Models Cooling Comm.
Compressor Max Max (kg) 400V Height (mm)*

EV3150B YPV066 15.0 27.0 7.4  180/250/380


Air Modbus
EV3185B YPV096 18.5 38.0 14.0  180/250/380
* Standard voltage air-cooled version including fins
** No matched drive with models YPV030-LT - YPV038-LT

Capacity data
Condensing Temperature +50°C
Cooling Capacity (kW) Power Input (kW)
R32 R32
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 -5 0 +5 +10 +15
Max 11.6 14.1 16.9 20.1 23.8 28.1 Max 5.9 6.1 6.3 6.4 6.5 6.5
YPV030LT YPV030LT
Min 2.7 2.7 3.7 3.1 3.7 4.3 Min 2.0 1.6 1.6 1.2 1.1 1.1
Max 14.9 18.1 21.6 25.8 30.5 35.8 Max 7.7 7.9 8.1 8.3 8.4 8.5
YPV038LT YPV038LT
Min 4.3 3.9 4.9 3.7 4.5 5.4 Min 2.8 2.2 2.2 1.7 1.6 1.6
Max 21.3 25.2 30.3 36.6 44 52.5 62.2 Max 13.2 13.4 13.7 14.0 14.2 14.5 14.7
YPV0661T YPV0661T
Min 6.9 6.2 7.3 8.8 10.6 12.6 15.0 Min 4.3 3.4 3.5 3.5 3.5 3.4 3.4
Max 31.7 37.6 45.2 54.6 65.6 78.4 92.9 Max 19.2 19.6 20.0 20.3 20.7 21.1 21.5
YPV0961T YPV0961T
Min 10.3 9.2 11.0 13.2 15.8 18.8 22.3 Min 6.2 4.8 4.9 4.9 4.8 4.7 4.5
Condition: Suction Superheat 5K, Subcooling 4K
Preliminary Data
27 GPC-EN-2024 COMFORT APPLICATIONS
Copeland XPV & ZPV variable speed scroll
compressor ranges for R410A with drive
Copeland XPV and ZPV variable speed scroll compressors for R410A are
designed to deliver maximum cooling and heating efficiency when you need
it most. Equipped with the latest variable speed technology, they allow system ZPV066
manufacturers and building owners to achieve superior performance when variable
designing reversible chillers, heat pumps, precision cooling systems or rooftops. speed scroll
compressor
In addition to Copeland market-proven robustness, the new XPV and ZPV and drive
ranges with their qualified drive meet and exceed the level of reliability expected
for these applications.

XPV and ZPV variable speed scroll compressor line-up


ZPV096
ZPV066
XPV046
XPV038
XPV030
XPV025
XPV018
kW cooling capacity
0 10 20 30 40 50 60 70 80 90 100

ZPV096 Tandems
ZPV066 Tandems

kW cooling capacity
0 25 50 75 100 125

Features and benefits Maximum allowable pressure (PS)


• Highest part load efficiency in its class enabling significant • XPV018-025 and XPV046
energy savings and standards compliance Low Side PS 28 bar(g) / High Side PS 45 bar(g)
• Wide speed range for enhanced part load efficiency and • XPV030-038
dehumidification: 900 -7,200 RPM (15-120Hz) Low Side PS 29.5 bar(g) / High Side PS 43.3 bar(g)
• Capability to be tandemized with fixed speed compressors • ZPV066 - 096
for maximum flexibility in system design Low Side PS 29.5 bar(g) / High Side PS 45 bar(g)
• Both compressor and drive are Copeland approved for
reduced design time, cost and speed to market
• BPM motor technology for highest efficiency
• Sound reduction technology for reversible chiller transition
and defrost

ZPV operating envelope R410A* XPV operating envelope R410A*


70 70
65 65
60 60
55 55
Condensing Temperature °C

Condensing Temperature °C

50 50
45 45
40 40
35 35
30 30
25 25
20 20
15 15
10 10
5 5
-35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30

Evaporating Temperature °C Evaporating Temperature °C

Note: * The operating envelope may vary depending on the compressor speed. Please refer to the Copeland Select software

GPC-EN-2024 COMFORT APPLICATIONS 28


Technical overview

Compressor

Cooling Capacity (kW) Length/ Sound


Stub Stub Oil Net
Displacement Width/ Pressure
Models EER* Suction Discharge Quantity weight
(cm3) Height @1 m -
Min Max Nominal (inch) (inch) (l) (kg)
(mm) dB(A)**

XPV0182E 1.3 10.4 8.2 3.0 18.0 3/4 1/2 0.7 194/216/335 16 61
XPV0252E 1.8 14.5 11.1 3.0 25.0 3/4 1/2 0.7 194/216/335 16 66
XPV0303E 2.2 17.4 13.5 3.1 30.0 3/4 1/2 1.2 194/217/379 19 64
XPV0383E 2.7 22.5 17.5 3.1 38.0 3/4 1/2 1.2 194/217/379 20 64
XPV0462E 6.2 24.0 20.5 3.2 46.0 3/4 1/2 1.2 229/198/388 22 n.a.
ZPV0662E 8.5 39.0 29.1 3.1 63.0 1 1/8 7/8 2.5 273/262/559 40 72
ZPV0962E 13.0 58.1 43.5 3.1 96.0 1 1/8 7/8 2.5 273/262/559 44 75
Conditions EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K
*at Nominal Speed (5400 RPM)
** @ 1m: sound pressure level at 1m distance from the compressor, free field condition
Preliminary Data

Drive

Power Amps Depth/


Net
Matched Input (kW) (A) 1ph 3Ph Width/
Models Cooling Weight Comm.
Compressor 230V 400V Height
Max Max (kg)
(mm)*
ED3015AU XPV018 3.8 15 2.8  205/240/144

ED3020AU XPV025 5.0 20 3.6  205/250/180


XPV025 / Air / Liquid Modbus
ED3018BU 5.0 18 4.4  RTU and 205/250/183
XPV030
analog
XPV038/ board for
ED3022B 8.0 22 5.2  233/316/150
XPV046 0-10V
EV3150B ZPV066 15.0 27 7.4  180/250/380
Air
EV3185B ZPV096 18.5 38 14.0  180/250/380

*Standard voltage air-cooled version including fins

Capacity data
Condensing Temperature +50°C
Cooling Capacity (kW) Power Input (kW)
R410A R410A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -15 -10 -5 0 +5 +10 +15 Model -15 -10 +5 +10 +15
Max 5.8 7.0 8.4 10.1 12.0 14.1 16.5 Max 3.6 3.7 3.7 3.7 3.7
XPV0182E XPV0182E
Min 1.5 1.6 1.7 1.7 2.0 2.4 2.9 Min 1.0 1.0 0.8 0.8 0.8
Max 7.2 8.8 10.8 13.2 15.8 18.8 22.2 Max 4.8 4.9 5.2 5.2 5.2
XPV0252E XPV0252E
Min 2.2 2.4 2.4 2.4 2.9 3.4 4.1 Min 1.4 1.4 1.1 1.1 1.0
Max 8.9 10.7 12.9 15.6 18.8 22.5 26.7 Max 5.5 5.6 5.9 6.0 6.0
XPV0303E XPV0303E
Min 2.2 2.5 1.5 1.9 2.3 2.7 3.7 Min 1.8 1.6 1.0 1.0 1.0
Max 11.3 13.6 16.4 19.8 23.8 28.5 33.8 Max 7.0 7.1 7.5 7.5 7.6
XPV0383E XPV0383E
Min 2.8 3.2 1.9 2.4 2.9 3.4 4.6 Min 2.2 2.0 1.2 1.2 1.3
Max 13.6 16.4 19.8 23.9 28.8 34.4 40.8 Max 8.1 8.3 8.7 8.7 8.7
XPV0462E XPV0462E
Min 3.6 4.5 2.2 2.8 3.3 4.0 5.1 Min 2.7 2.6 1.4 1.4 1.4
Max 19.1 23.3 28.2 34.0 40.6 48.2 56.8 Max 13.2 13.5 14.3 14.5 14.7
ZPV0662E ZPV0662E
Min 6.2 4.9 6.0 7.1 8.3 9.8 11.5 Min 4.2 3.0 2.9 2.8 2.8
Max 28.0 34.3 41.7 50.4 60.4 71.8 84.6 Max 18.2 18.7 20.0 20.4 20.8
ZPV0962E ZPV0962E
Min 9.1 7.5 9.0 10.8 12.8 15.2 18.0 Min 5.7 4.1 4.1 4.1 4.0
Condition: Suction Superheat 5K, Subcooling 4K

29 GPC-EN-2024 COMFORT APPLICATIONS


Copeland YH fixed speed scroll compressor range
for A2L refrigerants R454C and R452B

Copeland YH scroll compressors are designed for multiple


applications such as air-to-water and brine-to-water heat pumps,
process and close control cooling, as well as air conditioning. They
have a dedicated design to support the market needs of customers
for medium and low-pressure refrigerants with a low GWP. They are
suitable for very aggressive refrigerants containing HFO molecule.
YH compressors comply with the PED class requirements related to
A2L refrigerants.

YH scroll compressor

YH scroll compressor line-Up R454C and R452B

YH*K1E (R454C)
YH*K1P (R452B)

kW heating
capacity 0 5 10 15 20 25 30 35 40 45 50 55 60

Conditions: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K

Features and benefits Maximum allowable pressure (PS)


• Multi-refrigerant compressor: optimized for operation • R454C models
with A2L refrigerants with a low GWP R454C (148) and Low side PS 28 bar(g) / High Side PS 49 bar(g)
R452B (698) compared to R407C (1774) • R452B models
• PED class II certified Low side PS 28 bar(g) / High Side PS 46 bar(g)
• Fully hermetic compressor design
• Wide operating envelope for heat pump applications
• Low super heat
• Tandem-ready version available for all sizes
• F-gas compliant

YH*K1E operating envelope R454C YH*K1P operating envelope R452B


70 70

65 65

60 60

55 55
CondensingTemperature °C

50 50

45 45

40 40

35 35

30 30

25 25

20 20

15 15
-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30
Evaporating Temperature °C Evaporating Temperature °C

GPC-EN-2024 COMFORT APPLICATIONS 30


Technical overview

Motor Maximum Locked Sound


Length/
Heating Stub Stub Oil Net Version/ Operating Rotor Pressure
Nominal Displacement Width/
R454C Capacity Suction Discharge Quantity Weight Code Current (A) Current (A) @1 m
hp (m /h)
3
Height
(kW) (inch) (inch) (l) (kg) (dBA)
(mm)
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph** ***

YH04K1E 2.0 4.4 5.8 3/4 1/2 1.3 253/248/365 24.4 PFZ TFMN 11 5 61 26 60

YH06K1E 2.5 6.1 8.0 3/4 1/2 1.5 253/248/387 27.7 PFZ TFMN 16 6 76 32 61
YH07K1E 3.5 7.7 10.0 3/4 1/2 1.5 253/248/401 28.7 PFZ TFMN 21 8 97 46 64
YH09K1E 4.0 8.7 11.4 3/4 1/2 1.5 253/248/417 28.5 PFZ TFMN 24 9 114 50 60
YH11K1E 5.0 10.9 14.3 3/4 1/2 1.9 255/261/442 37.5 TFMN 11 64 65
YH13K1E 6.0 12.9 16.7 3/4 1/2 1.9 255/261/442 39.1 TFMN 13 74 65
YH23K1E 12.0 22.0 29.2 13⁄8 7⁄8 3.6 284/289/551 68.2 TFDN 23 147 68
YH28K1E 12.0 26.6 35.4 13⁄8 7⁄8 3.6 284/289/551 68.2 TFDN 29 147 68
YH33K1E 13.0 32.5 42.4 13⁄8 7⁄8 3.6 284/289/551 68.2 TFDN 34 141 71
YH38K1E 15.0 36.5 48.3 13⁄8 7⁄8 3.6 284/289/551 68.2 TFDN 39 186 71
Conditions: Evaporating -7°C, Condensing 50°C, Superheat 5K, Subcooling 4K
* 1ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Motor Maximum Locked Sound


Length/
Heating Stub Stub Oil Net Version/ Operating Rotor Pressure
Nominal Displacement Width/
R452B Capacity Suction Discharge Quantity Weight Code Current (A) Current (A) @1 m -
hp (m /h)
3
Height
(kW) (inch) (inch) (l) (kg) dB(A)
(mm)
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph** ***
YH04K1P 1.9 4.0 3.4 3/4 1/2 0.7 227/194/388 21.3 PFZ TFM 11 5 52 28 57
YH05K1P 1.9 4.7 4.0 3/4 1/2 0.7 227/194/388 21.3 PFZ TFM 13 5 60 28 58
YH06K1P 3.5 6.3 5.1 7/8 1/2 1.2 242/242/418 PFZ TFM 17 6 83 43 62
YH09K1P 3.5 8.5 6.9 7/8 1/2 1.2 242/242/418 33.0 PFZ TFM 23 7 108 52 63
YH12K1P 4.5 10.9 8.9 7/8 1/2 1.2 242/242/418 35.0 PFZ TFM 28 10 130 62 65
YH15K1P 6.0 14.4 11.7 7/8 1/2 1.9 245/249/442 39.5 TFM 13 75 67
Conditions: Evaporating -7°C, Condensing 50°C, Superheat 5K, Subcooling 4K *
1ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data
Condensing Temperature +50°C
Heating Capacity (kW) Power Input (kW)
R454C R454C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -30 -15 -10 -5 0 +5 +15 Model -30 -15 -10 -5 0 +5 +15
YH04K1E 3.4 4.0 4.7 5.5 6.4 8.6 YH04K1E 1.4 1.4 1.5 1.6 1.6 1.7
YH06K1E 4.8 5.6 6.5 7.6 8.9 12.1 YH06K1E 1.9 1.9 2.0 2.1 2.1 2.3
YH07K1E 6.0 7.0 8.2 9.5 11.1 15.0 YH07K1E 2.4 2.4 2.5 2.6 2.7 2.8
YH09K1E 6.9 8.0 9.3 10.8 12.6 17.1 YH09K1E 2.7 2.8 2.9 3.0 3.0 3.1
YH11K1E 8.5 9.9 11.6 13.5 15.8 21.3 YH11K1E 3.3 3.4 3.5 3.6 3.8 4.0
YH13K1E 10.0 11.7 13.7 16.0 18.6 25.2 YH13K1E 3.8 3.9 4.1 4.3 4.4 4.6
YH23K1E 10.7 17.4 20.2 23.4 27.1 31.4 41.9 YH23K1E 6.0 7.1 7.4 7.6 7.8 8.0 8.4
YH28K1E 12.4 20.8 24.3 28.2 32.7 37.8 50.3 YH28K1E 7.1 8.3 8.6 8.9 9.2 9.4 9.8
YH33K1E 15.5 25.5 29.7 34.5 40.0 46.4 62.3 YH33K1E 8.3 10.0 10.4 10.8 11.2 11.6 12.6
YH38K1E 16.9 28.4 33.2 38.8 45.2 52.6 70.8 YH38K1E 9.0 11.0 11.6 12.1 12.6 13.2 14.4
Conditions: Suction Superheat 5K / Subcooling 4K

Condensing Temperature +50°C


Heating Capacity (kW) Power Input (kW)
R452B R452B
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -30 -15 -10 -5 0 +5 +15 Model -30 -15 -10 -5 0 +5 +15
YH04K1P 3.2 3.7 4.2 4.9 5.6 7.5 YH04K1P 1.4 1.4 1.4 1.4 1.4 1.5

YH05K1P 3.7 4.3 5.0 5.8 6.7 8.8 YH05K1P 1.6 1.6 1.7 1.7 1.7 1.7

YH06K1P 5.0 5.8 6.6 7.6 8.8 11.6 YH06K1P 2.1 2.1 2.2 2.2 2.1 2.1
YH09K1P 6.8 7.8 9.0 10.4 11.9 15.6 YH09K1P 2.7 2.8 2.8 2.8 2.8 2.8

YH12K1P 8.5 10.0 11.5 13.3 15.3 20.1 YH12K1P 3.4 3.5 3.6 3.6 3.6 3.6

YH15K1P 11.4 13.2 15.2 17.5 20.1 26.4 YH15K1P 4.4 4.6 4.7 4.8 4.9 5.0
Conditions: Suction Superheat 5K / Subcooling 4K

31 GPC-EN-2024 COMFORT APPLICATIONS


Copeland ZH fixed speed scroll compressor range for R410A and R407C

Copeland ZH scroll compressor range

The ZH compressor range is optimized for reversible and heat


pump applications. In addition to the existing R407C range, a
complete new range optimized for R410A has been developed.
Both ranges are based on three platform sizes and cover a
capacity of 4kW to 38kW.

ZH heating compressors have been optimized for reversible


heating systems, they deliver higher capacity and efficiency at low
evaporating (heat source) temperatures and are therefore better
adapted to heating requirements than standard air conditioning
compressors. Due to their larger operating map they also require
less additional heating (electrical or gas) to cover the full heating
demand on the coldest days and therefore further improve the
system seasonal efficiency.

ZH scroll compressor
Copeland ZH scroll compressors
with enhanced vapor injection

ZH heating compressors with Enhanced Vapor Injection have discharge temperature and the extension of the operating
been further optimized to ensure best-in-class performances envelope which enable the production of high temperature water
in dedicated heating applications. This technology allows at all working conditions.
replacement of traditional boilers in new building and retrofit
applications, without the need of substituting existing heating ZHI heating compressors reach the same high standards of
elements in the building. durability and reliability as other Copeland scroll compressors.
This includes the ability to handle relatively large amounts of
ZH Copeland scroll heating compressors with Enhanced liquid, which is known to damage or cause compressor failures.
Vapor Injection have an additional port to inject vapor within Fewer moving parts, robust running gear and low vibration due
the compression process. This improves system performances to balanced compression mechanism make the ZH range of
by increasing the heating capacity for a given compressor Copeland scroll compressors the most reliable solution available
displacement. Additional benefits are the reduction of the gas in the heat pump market.

ZH nomenclature guidelines

ZH**K4E ZH**K1P
Qualified for R407C/R134a Qualified for R410A only
without enhanced vapor injection - ** capacity in Btu/h without enhanced vapor injection – ** capacity in kW
ZH**KVE ZHI**K1P
Qualified for R407C only Qualified for R410A only
enhanced vapor injection – ** capacity in kW enhanced vapor injection – ** capacity in kW

ZH**KRE
Qualified for R513A
without enhanced vapour injection ** capacity in kW

Enhanced vapor injection: system design Enhanced vapor injection: enthalpy diagram

m+i
Condenser
i
P
m+i
Solenoid Valve
i

Enhanced vapor injection


i
Scroll
Eco

m
m
Evaporator
EV h

GPC-EN-2024 COMFORT APPLICATIONS 32


ZH*K4E / ZH*KVE scroll compressor line-up R407C

Single phase ZH*KVE with Enh. vapor Inj.


ZH*K4E without Enh. vapor Inj.

Three phase

kW heating
0 5 10 15 20 25 30 35 40 45 50

Conditions: Evaporating -7°C, Condensing 50°C, 4K Subcooling, 5K Superheat

ZH*P / ZHI*P scroll compressor line-up R410A

Single phase ZHI*P with Enh. vapor Inj.


ZH*P without Enh. vapor Inj.

Three phase

kW heating
0 5 10 15 20 25 30 35 40 45 50

Conditions: Evaporating -7°C, Condensing 50°C, 4K Subcooling, 5K Superheat

ZH*KRE scroll compressor line-up R513A


Single phase
kW heating
0 5 10 15 20 25 30 35 40 45 50

Features and benefits Maximum allowable pressure (PS)


• Copeland scroll axial and radial compliance for high reliability • ZH(I)04K1P to ZH(I)23K1P:
• High efficiency and increased heating capacity Low Side PS 28 bar(g) / High Side PS 45 bar(g)
• ZHI27K1P to ZHI46K1P:
• High water temperature for all applications Low Side PS 29.5 bar(g) / High Side PS 53 bar(g)
• Low sound and low vibration level • ZH12K4E to ZH45K4E:
• Tandem combination for superior seasonal efficiency Low Side PS 20 bar(g) / High Side PS 32 bar(g)
• Enhanced Vapor Injection technology for best seasonal efficiency • ZH09KVE to ZH18KVE:
Low Side PS 20 bar(g) / High Side PS 32 bar(g)

Operating envelope R410A heating Operating envelope R407C heating


70 70

65 65

60 60
Condensing Temperature °C

55
CondensingTemperature °C

55

50 50

45 45

40 40

35 35

30 30

25 25

20 20

15 15
-35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30
Evaporating Temperature °C Evaporating Temperature °C

ZH*P without Enh. Vapor Inj. ZHI*P 2000 Hours Max. ZH*P without Enh. vapor Inj. ZHI*P 2000 hours max.
ZH*P 2000 Hours Max. Wet Injection ZH*P 2000 hours max. Wet injection
ZHI*P with Enh. Vapor Inj. ZHI*P with Enh. vapor Inj.

Refer to Copeland Select Software for individual model operating envelopes and other refrigerants.

33 GPC-EN-2024 COMFORT APPLICATIONS


Technical overview

Stub Discharge
Maximum

Displacement
Sound

Stub Suction

Oil Quantity
Length/ Motor Version/ Locked Rotor

Capacity
Operating
Nominal
Net Pressure

(m3/h)
Code Current (A)

(inch)

(inch)
Width/

(kW)

COP
Current (A)
hp
R410A Weight @1 m -

(l)
Height
(kg) dB(A)
(mm)
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph** ***

ZH04 K1P 1.8 4.2 2.8 3.4 3/4 1/2 0.7 229/198/388 22 PFZ TFM 9 5 50 28 62
ZH05 K1P 2.0 5.0 2.8 4.0 3/4 1/2 0.7 229/198/388 22 PFZ TFM 13 5 60 28 62
ZH06 K1P 2.7 6.6 2.9 5.1 7/8 1/2 1.2 242/242/418 31 PFZ TFM 17 6 83 44 62
ZH09 K1P 3.5 9.0 3.1 6.9 7/8 1/2 1.2 242/242/418 33 PFZ TFM 23 7 108 52 62
ZH12 K1P 4.5 11.4 3.0 8.9 7/8 1/2 1.2 242/242/418 35 PFZ TFM 28 10 130 62 65
ZH15 K1P 5.0 15.1 3.1 11.7 7/8 1/2 1.9 245/249/442 39 TFM 13 75 67
ZH19 K1P 6.5 18.7 3.2 14.8 7/8 3/4 1.9 239/244/443 39 TFM 17 67
ZHI05 K1P 1.9 5.2 3.0 3.4 3/4 1/2 0.7 229/198/388 22 PFZ TFM 14 4 60 28 63
ZHI08 K1P 2.8 8.2 3.1 5.1 7/8 1/2 1.2 242/242/418 31 PFZ TFM 19 6 108 43 63
ZHI11 K1P 3.6 10.8 3.2 6.9 7/8 1/2 1.2 242/242/418 31 PFZ TFM 25 9 130 52 65
ZHI14 K1P 4.6 13.9 3.3 8.9 7/8 1/2 1.2 242/242/418 34 TFM 11 70 65
ZHI18 K1P 5.0 17.9 3.4 11.7 7/8 1/2 1.9 249/245/443 41 TFM 15 67
ZHI23 K1P 6.5 22.8 3.4 14.8 7/8 3/4 1.9 239/244/443 41 TFM 19 67
ZHI27 K1P 9.0 27.0 3.3 16.8 1 3/8 7/8 3.3 280/280/533 63 TFD 21.0 118 77
ZHI32 K1P 10.0 31.7 3.2 19.8 1 3/8 7/8 3.3 280/280/533 63 TFD 26.0 140 75
ZHI35 K1P 12.0 35.6 3.2 22.1 1 3/8 7/8 3.3 280/284/568 63 TFD 32.5 174 76
ZHI40 K1P 13.0 39.7 3.3 24.9 1 3/8 7/8 3.3 284/280/568 64 TFD 33.0 174 76
ZHI46 K1P 15.0 46.6 3.3 29.1 1 3/8 7/8 3.4 284/280/568 64 TWD 37.4 168 78
Conditions: Evaporating -7°C, Condensing 50°C, Superheat 5K, Subcooling 4K
* 1 Ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition
Stub Discharge
Displacement

Maximum
Locked Rotor Sound
Stub Suction

Oil Quantity

Length/ Motor Version/


Capacity
Nominal

Net Operating Pressure


(m3/h)

(inch)

(inch)

Width/ Code Current (A)


(kW)

COP

Current (A)
hp

R407C Weight @1 m -
(l)

Height
(kg) dB(A)
(mm)
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph** ***

ZH12K4E 1.7 3.7 3.0 4.7 3/4 1/2 0.7 272/193/388 21 PFZ 10 44 53
ZH15K4E 2.0 4.6 3.0 5.8 3/4 1/2 1.3 243/243/364 23 PFJ TFD 12 4 61 26 60
ZH06KVE 2.5 6.1 3.3 5.8 3/4 1/2 1.3 243/243/364 28 TFM 4 26 58
ZH19K4E 2.5 5.9 3.0 7.3 3/4 1/2 1.5 243/242/387 25 PFJ TFD 17 6 74 32 60
ZH09KVE 3.0 8.3 3.3 8.0 3/4 1/2 1.5 243/243/386 30 PFZ TFD 21 7 97 40 62
ZH21K4E 3.0 6.5 3.1 8.0 3/4 1/2 1.5 243/242/387 27 PFJ TFD 19 5 76 32 61
ZH26K4E 3.5 8.2 3.1 10.0 3/4 1/2 1.5 243/242/400 28 PFJ TFD 21 7 97 46 64
ZH13KVE 4.0 11.9 3.4 11.7 7/8 1/2 1.9 244/241/438 38 PFJ TFD 30 10 160 74 68
ZH30K4E 4.0 9.5 3.1 11.7 7/8 1/2 1.9 247/241/438 38 PFJ TFD 25 8 108 64 65
ZH38K4E 5.0 11.7 3.2 14.4 7/8 1/2 1.9 247/241/438 38 PFZ TFD 31 10 150 64 66
ZH18KVE 6.0 16.8 3.4 17.1 7/8 1/2 1.9 244/241/438 40 TFD 14 101 65
ZH45K4E 6.0 14.0 3.2 17.1 7/8 1/2 1.9 250/246/438 40 TFD 12 74 67
Conditions: Evaporating -7°C, Condensing 50°C, Superheat 5K, Subcooling 4K
* 1 Ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition
Stub Discharge
Displacement

Motor Maximum
Locked Rotor Sound
Stub Suction

Oil Quantity

Length/
Capacity

Version/ Operating
Nominal

Net Pressure
(m3/h)

(inch)

(inch)

Width/ Current (A)


(kW)

COP

Code Current (A)


hp

R513A Weight @1 m -
(l)

Height
(kg) dB(A)
(mm)
1 Ph* 1 Ph* 1 Ph* ***

ZH21KRE 2.0 3.1 2.1 8.0 3/4 1/2 1.5 243/242/387 27 PFJ 19 76 61
ZH26KRE 3.0 3.1 2.1 10.0 3/4 1/2 1.5 243/242/400 28 PFJ 21 97 63
Conditions: Evaporating -7°C, Condensing 50°C, Superheat 5K, Subcooling 4K
* 1 Ph: 230V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

GPC-EN-2024 COMFORT APPLICATIONS 34


Capacity data
Condensing Temperature +50°C
Heating Capacity (kW) Power Input (kW)
R410A R410A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -30 -15 -10 -5 0 +5 +15 Model -30 -15 -10 -5 0 +5 +15
ZH04 K1P 3.3 3.9 4.5 5.2 6.0 7.6 ZH04 K1P 1.4 1.5 1.5 1.5 1.5 1.5
ZH09 K1P 7.1 8.2 9.5 10.9 12.5 16.4 ZH09 K1P 2.8 2.9 3.0 3.0 3.0 3.0
ZH12 K1P 9.2 10.5 12.1 13.9 15.9 21.0 ZH12 K1P 3.7 3.7 3.8 3.8 3.8 3.8
ZH15 K1P 12.0 13.8 15.9 18.4 21.1 27.7 ZH15 K1P 4.7 4.9 5.0 5.1 5.2 5.2
ZH19 K1P 15.2 17.5 20.2 23.2 26.7 35.1 ZH19 K1P 6.0 6.2 6.3 6.4 6.5 6.5
Models with Enhanced Vapor Injection
ZHI05 K1P 2.6 4.2 4.8 5.4 6.1 6.9 8.6 ZHI05 K1P 1.7 1.7 1.7 1.8 1.8 1.8 1.7
ZHI08 K1P 5.0 6.7 7.6 8.4 9.4 10.5 13.1 ZHI08 K1P 2.5 2.6 2.6 2.6 2.6 2.6 2.4
ZHI11 K1P 6.4 9.0 10.1 11.3 12.6 14.0 17.2 ZHI11 K1P 3.2 3.3 3.3 3.3 3.3 3.3 3.1
ZHI14 K1P 8.5 11.6 13.0 14.5 16.2 18.1 22.3 ZHI14 K1P 3.9 4.1 4.2 4.2 4.2 4.2 4.0
ZHI18 K1P 10.8 14.9 16.7 18.7 20.9 23.2 28.7 ZHI18 K1P 5.1 5.3 5.4 5.4 5.4 5.3 5.2
ZHI23 K1P 13.8 19.0 21.3 23.9 26.6 29.7 36.7 ZHI23 K1P 6.6 6.8 6.9 6.9 6.9 6.8 6.6
ZHI27 K1P 14.2 22.1 25.1 28.4 31.8 35.5 43.8 ZHI27 K1P 7.9 8.2 8.2 8.1 8.1 7.9 7.5
ZHI32 K1P 16.4 26.1 29.5 33.2 37.1 41.4 51.1 ZHI32 K1P 8.7 9.7 9.8 9.8 9.7 9.6 9.4
ZHI35 K1P 19.5 29.2 33.1 37.3 41.9 46.7 57.4 ZHI35 K1P 11.0 10.8 10.9 11.0 11.1 11.2 11.1
ZHI40 K1P 21.7 32.5 36.9 41.7 47.0 52.7 65.6 ZHI40 K1P 12.0 12.0 12.1 12.1 12.2 12.2 12.3
ZHI46 K1P 26.1 38.7 43.5 48.7 54.3 60.4 74.0 ZHI46 K1P 13.2 14.0 14.1 14.1 14.1 14.1 14.0
Conditions: Suction Superheat 5K / Subcooling 4K

Condensing Temperature +50°C


Heating Capacity (kW) Power Input (kW)
R407C R407C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -30 -15 -10 -5 0 +5 +15 Model -30 -15 -10 -5 0 +5 +15
ZH12K4E 2.8 3.3 3.9 4.6 5.4 7.5 ZH12K4E 1.2 1.2 1.3 1.3 1.3 1.4
ZH15K4E 3.6 4.3 5.0 5.8 6.8 9.2 ZH15K4E 1.5 1.5 1.6 1.6 1.6 1.9
ZH21K4E 5.1 5.9 6.9 8.1 9.6 13.2 ZH21K4E 2.0 2.1 2.1 2.2 2.3 2.4
ZH26K4E 6.3 7.4 8.7 10.3 12.1 16.5 ZH26K4E 2.5 2.6 2.7 2.7 2.8 3.0
ZH30K4E 7.3 8.6 10.1 11.9 14.0 19.2 ZH30K4E 2.9 3.0 3.1 3.2 3.3 3.4
ZH38K4E 9.0 10.6 12.5 14.6 17.2 23.4 ZH38K4E 3.5 3.6 3.8 3.9 4.0 4.2
ZH45K4E 10.8 12.7 14.9 17.4 20.3 27.2 ZH45K4E 4.2 4.3 4.5 4.6 4.7 5.1
Models with Enhanced Vapor Injection
ZH06KVE 3.3 4.9 5.7 6.5 7.4 8.4 10.8 ZH06KVE 1.7 1.8 1.9 1.9 2.0 2.0 2.1
ZH09KVE 4.1 6.6 7.6 8.7 9.9 11.2 14.3 ZH09KVE 2.1 2.4 2.4 2.5 2.6 2.6 2.6
ZH13KVE 5.7 9.5 10.9 12.5 14.3 16.2 20.7 ZH13KVE 3.0 3.4 3.5 3.5 3.6 3.6 3.7
ZH18KVE 8.0 13.5 15.4 17.6 20.0 22.6 28.7 ZH18KVE 4.2 4.8 4.9 5.0 5.1 5.1 5.2
Conditions: Suction Superheat 5K / Subcooling 4K

Condensing Temperature +50°C


Heating Capacity (kW) Power Input (kW)
R513A R513A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -30 -15 -10 -5 0 +5 +15 Model -30 -15 -10 -5 0 +5 +15
ZH21KRE 3.4 4.0 4.8 5.6 6.6 9.0 ZH21KRE 1.4 1.5 1.5 1.6 1.6 1.7

ZH26KRE 4.5 5.3 6.2 7.2 8.4 11.5 ZH26KRE 1.9 1.9 2.0 2.0 2.1 2.2
Conditions: Suction Superheat 5K / Subcooling 4K
Single phase only

35 GPC-EN-2024 COMFORT APPLICATIONS


Copeland YHV variable speed scroll compressor range
for A2L refrigerants R452B/R454B with drive
Copeland YHV*2P compressor range is designed to support system
manufacturers build brine-to-water or air-to-water heat pumps that
meet the requirements of the F-gas phasedown. These scrolls are
qualified to reach a wide operating envelope without the need of
enhanced vapor injection (EVI).

The matched drives are qualified per EN60335-1 and available


for 1ph and 3ph power supply. YHV*2P compressors and their
matched drives belong to PED category II and therefore comply
with stringent quality requirements: they are hermetically sealed
and electrical connections are not source of ignition. This solution is
offered to system manufacturers as a CE certified package for faster
time to market and for the highest level of compressor protection. YHV*2P scroll variable speed
compressor and drive
YHV variable speed scroll compressor line-up

YHV038

YHV025

YHV018

kW heating
capacity 0 5 10 15 20 25 30 35

Conditions: Heating kW Evaporating -7°C, Condensing 50°C, 5K Superheat, 4K Subcooling

Features and benefits Operating


Operating Envelope
envelope R410A
R454B
• Speed range from 15 to 120 Hz 70

• Drive available in air-cooled and flat plate version


60
• Axial and radial compliance for reliability
• Compressor model with 3-feet for compact units
Condensing Temperature °C

50
• Pre-compliant solution to relevant application standards
(EN378, EN60335), to facilitate system development 40
• F-gas compliant
30

Maximum allowable pressure (PS)


20

• Low side PS 28 bar(g) / High Side PS 49 bar(g)


10

0
-40 -30 -20 -10 0 10 20 30

Evaporating Temperature °C

XHV
ZHW

GPC-EN-2024 COMFORT APPLICATIONS 36


Technical overview

Compressor

Heating Capacity (kW) Length/ Sound


Stub
Displacement Stub Suction Oil Quantity Width/ Net Weight Pressure
Models COP* Discharge
(cm )
3
(inch) (l) Height (kg) @1 m -
Nominal (inch)
Min Max (mm) dB(A)**
Capacity

YHV0182P 2.6 10.1 6.2 2.0 18 3/4 1/2 0.7 194/216/335 15 61


YHV0252P 3.9 12.4 8.4 2.1 25 3/4 1/2 0.7 194/216/335 16 65
YHV0382P 5.4 21.4 12.6 2.2 38 3/4 1/2 1.2 216/194/385 20 64
Conditions: Evaporating -7°C, Condensing 50°C, Superheat 10K, Subcooling 0K *at
Nominal Speed (90Hz)
** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Drive

Power input (kW) Amps (A) Length/


Matched Net Weight 1Ph 3Ph Width/
Models Cooling Comm.
Compressor (kg) 230V 400V Height
Min Max (mm)*
ED3011AU YHV018 2.6 11 2.8 √ n.a. 205/240/143
ED3015AU YHV025 3.8 15 2.8 √ n.a. 205/240/143
Air /
ED3020AU YHV025-38 5.5 20 3.6 √ n.a. Modbus 205/250/180
Liquid
ED3013BU YHV018 4.4 13 3.4 n.a. √ 205/250/183
ED3018BU YHV025-38 6.0 18 4.4 n.a. √ 205/250/183
*Air-cooled version including fins

Capacity data
Condensing Temperature +50°C
Heating Capacity (kW) Power Input (kW)
R452B R452B
Evaporating Temperature (°C) Evaporating Temperature (°C)
Models -15 -10 -5 0 5 +10 +15 Models -15 -10 -5 0 5 +10 +15
Max 7.8 9.0 10.3 11.9 13.4 14.2 14.9 Max 3.2 3.3 3.3 3.4 3.3 3.1 2.8
YHV0182P YHV0182P
Min 3.2 3.7 4.3 4.9 5.6 6.4 7.2 Min 1.3 1.3 1.4 1.4 1.4 1.4 1.3
Max 10.5 12.3 14.2 16.3 18.5 19.6 20.6 Max 4.2 4.5 4.6 4.7 4.7 4.3 4.0
YHV0252P YHV0252P
Min 5.2 5.1 5.8 6.7 7.7 8.8 10.0 Min 2.6 1.8 1.8 1.8 1.8 1.8 1.8
Max 12.9 16.1 18.6 21.4 24.6 27.7 28.3 Max 4.7 5.6 5.8 5.9 6.1 6.1 5.4
YHV0382P YHV0382P
Min 6.6 7.7 8.8 10.2 11.7 13.3 15.2 Min 2.6 2.7 2.7 2.7 2.8 2.8 2.8
Conditions: Suction Superheat 10K / Subcooling 0K

Condensing Temperature +50°C


Heating Capacity (kW) Power Input (kW)
R454B R454B
Evaporating Temperature (°C) Evaporating Temperature (°C)
Models -15 -10 -5 0 5 +10 +15 Models -15 -10 -5 0 5 +10 +15
Max 7.7 9.9 10.0 11.5 13.0 13.8 14.5 Max 3.2 4.5 3.3 3.3 3.3 3.0 2.8
YHV0182P YHV0182P
Min 3.1 3.6 4.1 4.7 5.4 6.2 7.0 Min 1.3 1.3 1.3 1.3 1.4 1.3 1.3
Max 10.4 11.9 13.8 15.8 17.9 19.0 20.0 Max 4.3 4.4 4.5 4.6 4.6 4.3 3.9
YHV0252P YHV0252P
Min 4.3 4.9 5.7 6.5 7.5 8.6 9.7 Min 1.7 1.8 1.8 1.8 1.8 1.8 1.8
Max 13.2 15.7 18.1 20.9 24.0 27.0 27.7 Max 5.2 5.5 5.7 5.9 6.0 6.0 5.3
YHV0382P YHV0382P
Min 6.4 7.5 8.6 9.9 11.3 12.9 14.7 Min 2.6 2.7 2.7 2.7 2.7 2.7 2.7
Conditions: Suction Superheat 10K / Subcooling 0K

37 GPC-EN-2024 COMFORT APPLICATIONS


Copeland XHV & ZHW variable speed scroll
compressor ranges for R410A with drive
XHV and ZHW variable speed scroll compressors for
R410A, for outstanding performance for cooling and
heating applications.

XHV and ZHW compressors deliver outstanding


performances, both in new building and retrofit applications.
Variable speed Copeland scroll compressors feature a state-
of-the-art brushless permanent magnet motor matched with
a highly efficient drive and vapor injection technology (ZHW
only). In addition to Copeland market-proven robustness,
XHV and ZHW compressors with the qualified drive meet and
exceed the level of reliability expected for these demanding ZHW scroll variable speed
applications. compressor and drive

XHV & ZHW variable speed scroll compressor line-up

ZHW030

ZHW015

XHV038

XHV025

XHV018

kW heating
capacity 0 5 10 15 20 25 30 35

Conditions: Cooling kW Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K


Heating kW Evaporating -7°C, Condensing 50°C, 5K Superheat, 4K Subcooling

Features and benefits Operating envelope R410A


70
• Highest efficiency throughout the operating envelope
and speed range
60
• Envelope and speed management information for the
system controller (real-time communication via
Condensing Temperature °C

50
Modbus RS485)
• Enhanced Vapor Injection technology for best seasonal
40
efficiency (ZHW)
• High water temperature for all applications
30
• Compliance with electromagnetic-compatibility (EMC)
and electromagnetic-interference (EMI) requirements
20
for residential applications
• VDE certification for ZHW compressor and matched drive
10
• Wide speed range 15-120Hz
• Mutually optimized and qualified scroll and drive
0
-40 -30 -20 -10 0 10 20 30

Evaporating Temperature °C

XHV
Maximum allowable pressure (PS) ZHW

• ZHW:
Low side PS 28 bar(g) / High side PS 45 bar(g)
• XHV:
Low side PS 28 bar(g) / High side PS 45 bar(g)

GPC-EN-2024 COMFORT APPLICATIONS 38


Technical overview
Compressor

Heating Capacity (kW) Length/ Sound


Stub Stub Oil Net
Displacement Width/ Pressure
R410A COP* Suction Discharge Quantity Weight
(cm3) Height @1 m -
Nominal (inch) (inch) (l) (kg)
Min Max (mm) dB(A)**
Capacity

ZHW0152P 2.7 10.4 6.1 2.9 15.0 3/4 1/2 1.7 229/198/394 20 68
ZHW0302P 5.5 19.8 11.8 3.2 30.0 3/4 1/2 1.7 229/198/394 20 68
XHV0181P 2.6 10.7 6.4 3.0 18.0 3/4 1/2 0.7 218/198/334 15 61
XHV0251P 3.7 14.8 8.6 3.1 25.0 3/4 1/2 0.7 218/198/334 16 65
XHV0382P 5.5 22.8 13.0 3.1 38.0 3/4 1/2 1.2 218/198/384 20 64
Conditions: Evaporating -7°C, Condensing 50°C
*@ Nominal Speed (90Hz)
** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Drive

Matched Power Input (kW) Amps (A) Net Weight Length/Width/


Model Cooling 1Ph 230V3Ph 400V Comm.
Compressor (kg) Height (mm)*
Nominal Nominal
EV2055M ZHW015 5.5 Air / 3.6 √ √ 228/260/119
Modbus
EV2080M ZHW030 8.0 Liquid 5.1 √ √ 228/260/156

ED3015AU XHV018-25 3.8 15 2.8 √ n.a. 205/240/143


ED3020AU XHV025-38 5.5 20 Air / 3.6 √ n.a. 205/250/180
ED3013BU XHV018-25 4.4 13 Liquid 3.4 n.a. √ Modbus 205/250/183
ED3018BU XHV025-38 6.0 18 4.4 n.a. √ 205/250/183
ED3022B XHV038 8.8 22 Air 5.2 n.a. √ 233/316/150
*Air-cooled version including fins

Capacity data
Condensing Temperature +50°C
Heating Capacity (kW) Power Input (kW)
R410A R410A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -30 -15 -10 -5 0 +5 +15 Model -30 -15 -10 -5 0 +5 +15
Max 6.0 8.6 9.7 11.0 12.0 12.0 12.4 Max 3.1 3.3 3.3 3.4 3.2 2.9 2.4
ZHW0152P ZHW0152P
Min 2.0 2.6 2.8 2.9 3.1 3.1 3.8 Min 1.3 1.1 1.1 1.0 0.9 0.9 0.9
Max 11.3 16.3 18.5 20.8 22.6 22.6 23.7 Max 5.7 6.0 6.1 6.1 5.7 5.4 4.4
ZHW0302P ZHW0302P
Min 4.2 5.2 5.8 5.9 6.6 6.6 8.1 Min 2.4 2.0 2.0 1.9 1.7 1.7 1.7
Condition: Suction Superheat 10K, Subcooling 4K

Condensing Temperature +50°C


Heating Capacity (kW) Power Input (kW)
R410A R410A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -20 -15 -10 -5 0 +5 +15 Model -20 -15 -10 -5 0 +5 +15
Max 7.7 8.7 9.9 11.3 12.9 14.4 16.2 Max 3.4 3.5 3.6 3.7 3.7 3.6 3.1
XHV0181P XHV0181P
Min 2.2 2.4 2.5 2.6 2.5 2.8 3.7 Min 1.0 1.0 1.0 0.9 0.8 0.8 0.8
Max 10.3 11.8 13.6 15.7 18.1 20.4 22.8 Max 4.5 4.7 4.9 5.0 5.1 5.1 4.4
XHV0251P XHV0251P
Min 3.2 3.4 3.6 3.7 3.5 4.0 5.0 Min 1.4 1.4 1.3 1.2 1.1 1.1 1.0
Max 15.8 18.1 20.9 24.1 27.8 31.4 35.0 Max 6.9 7.1 7.4 7.6 7.8 7.8 6.7
XHV0382P XHV0382P
Min 4.7 5.1 5.5 5.6 5.4 6.1 7.7 Min 2.1 2.1 2.0 1.9 1.6 1.6 1.6
Condition: Suction Superheat 5K, Subcooling 4K

39 GPC-EN-2024 COMFORT APPLICATIONS


ZH Copeland scroll for heat recovery and
high condensing applications for R134a
ZH*KCE R134a Copeland scroll compressors were developed for the
recovery and reuse of available heat. For example, the heat generated by
processes or machining cooling equipment can be recovered and not
wasted. This contributes to reducing the total energy cost of installations.
On a water-cooled chiller, heat recovery on the condensing water loop
can be used to produce high temperature water for sanitary or premise
heating. With a typical evaporating temperature between 20°C and 40°C
and condensing up to 85°C, ZH*KCE scrolls offer many opportunities of
heat recovery.

The range of products goes from the ZH40KCE (7.5hp) to the ZH150
(30hp) which can be tandemized.

ZH*KCE scroll compressor for


heat recovery

ZH*KCE scroll compressor line-up R134a

Single

Tandem

kW Heating Capacity
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

Conditions: Evaporating 40°C, Condensing 85°C, Superheat 10K, Subcooling 5K

Features and benefits Operating envelope R134a


95
• Copeland scroll axial and radial compliance for superior
reliability and efficiency 85

• Wide scroll line-up R134a with 8 models and tandem 75


• Low sound and vibration level
Condensing Temperature °C

65
• Low oil circulation rate
• Copeland qualified tandem 55

45

35

Typical applications 25

15
• Heat recovery on the dry cooler water circuit of a water-
cooled chiller to produce sanitary water or other heating 5
-20 -10 0 10 20 30 40
• Re-inject energy to district heating network and 50

avoid wasting it Evaporating Temperature °C


• Process industry where the water returning from the
machinery comes back between 20 and 40°C
• Food industry where one areas needs cooling and another
heating at the same time
• Air-to-water heat pump, even during the warm season Maximum allowable pressure (PS)
• Exhaust air heat recovery system
• Heat recovery on Fluegas • Low side PS 20 bar(g) / High side PS 32 bar(g)

GPC-EN-2024 COMFORT APPLICATIONS 40


Technical overview

Motor Version /
Length/Width/Height

Locked Rotor
Stub Suction (inch)

Current (A)

Current (A)
Heating Capacity

Operating
Maximum

Sound Pressure
Stub Discharge

@1 m - dB(A)**
Displacement
Heating COP

Code
Oil Quantity

Net Weight
Nominal

(m3/h)

(inch)

(mm)
(kW)

(kg)
hp
Models

(l)
3 Ph* 3 Ph* 3 Ph*

ZH40KCE 7.5 39.0 4.3 22.1 1 1/8 7/8 2.7 264 / 285 / 476 57 TFD 19 95 63
ZH45KCE 9.0 44.0 4.6 24.9 1 /8 3
7/8 3.4 264 / 285 / 533 60 TFD 21 111 63
ZH50KCE 10.0 50.9 4.5 29.1 1 /8 3
7/8 3.4 264 / 285 / 533 61 TFD 23 118 63
ZH64KCE 13.0 63.7 4.3 36.4 1 /8 3
7/8 3.4 264 / 285 / 552 65 TFD 27 140 68
ZH75KCE 15.0 76.0 4.2 43.4 1 3/8 7/8 3.4 264 / 285 / 552 66 TFD 35 174 71
ZH100KCE 20.0 96.1 4.0 56.6 1 /8 5
1 /8 3
4.7 432 / 376 / 694 140 TWD 42 225 72
ZH125KCE 25.0 120.0 4.1 71.4 1 /8 5
1 /8 3
6.8 447 / 392 / 717 160 TWD 53 272 74
ZH150KCE 30.0 148.8 4.2 87.5 1 5/8 1 3/8 6.3 447 / 427 / 717 177 TWD 67 310 76
Conditions Evaporating 40°C - Condensing 85°C - Superheat 5K - Subcooling 4K
* 3 Ph: 380-420V/ 50Hz
** @ 1m: sound pressure level at 1m distance from the compressor, free field condition
For equivalent models to ZH45-75KCE with R513A, please refer to models ZR108-190KRE on pages 11.

Capacity data
Condensing Temperature +80°C
Heating Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Models +10 +15 +20 +25 +30 +35 +40 Models +10 +15 +20 +25 +30 +35 +40
ZH40KCE 16.9 19.7 22.9 26.5 30.7 35.6 41.1 ZH40KCE 8.3 8.3 8.2 8.1 8.1 8.1 8.1
ZH45KCE 20.2 23.2 26.5 30.5 35.0 40.3 46.5 ZH45KCE 8.7 8.7 8.7 8.7 8.7 8.7 8.7
ZH50KCE 23.1 26.6 30.6 35.2 40.5 46.7 53.8 ZH50KCE 10.2 10.2 10.2 10.2 10.2 10.2 10.2
ZH64KCE 28.7 33.1 38.1 43.9 50.7 58.4 67.3 ZH64KCE 13.5 13.5 13.4 13.4 13.5 13.5 13.6
ZH75KCE 34.8 39.9 45.8 52.6 60.5 69.7 80.3 ZH75KCE 16.2 16.2 16.2 16.2 16.3 16.4 16.7
ZH100KCE 46.4 52.6 59.9 68.3 77.9 88.9 101.5 ZH100KCE 21.1 21.3 21.4 21.5 21.5 21.5 21.6
ZH125KCE 57.6 65.4 74.4 84.8 96.9 111.0 127.0 ZH125KCE 27.6 26.6 26.6 26.5 26.4 26.3 26.3
ZH150KCE 71.0 80.7 91.9 105.0 120.0 137.0 157.0 ZH150KCE 30.7 31.2 31.5 31.8 32.0 32.3 32.5
Conditions: Suction Superheat 5K / Subcooling 4K

41 GPC-EN-2024 COMFORT APPLICATIONS


ZRH(V) & YRH(V) Copeland scroll horizontal compressor
ranges for R513A, R454C, R407C and R134a
Air conditioning for passenger comfort is a pre-requisite in today’s
public transport vehicles. At the same time, maximization of passenger
space and streamlining of high speed trains increasingly impose
limitations on height.

ZRH compressors are based on the unique Copeland scroll design


and provide the same reliability as a standard Copeland scroll.
An additional oil pump covers the specific needs of transport air
conditioning and of horizontal compressor arrangement in general.

The low profile design and modulation capabilities of the ZRH


compressor range are the ideal response to these market needs.
ZRH horizontal scroll compressor

ZRH & YRH scroll compressors line-up R513A, R454C, R407C and R134a

YRH72-81KTE (R454C)

ZRH72-116KTR (R513A)

ZRH72-81KTE (R407C)

ZRH72-81KTE (R134a)

kW Cooling
Capacity 0 5 10 15 20 25 30 35

ZRHV & YRHV variable speed scroll compressors line-up


R513A, R454C, R407C and R134a

YRHV72*KTE (R454C)
YRHV81*KTE (R454C)
ZRHV72*KTR (R513A)
ZRHV81*KTR (R513A)
ZRHV72*KTE (R407C)
ZRHV81*KTE (R407C)
ZRHV94*KTE (R407C)

ZRHV72*KTE (R134a)
ZRHV81*KTE (R134a)
ZRHV94*KTE (R134a)

kW Cooling
Capacity 0 5 10 15 20 25 30 35

Conditions: EN12900: Evaporating 5°C, Condensing 50°C, Superheat 10K, Subcooling 0K

Features and benefits Maximum allowable pressure (PS)


• Compact and low weight Low Side PS 20 bar(g) / High Side PS 32 bar(g)
• Horizontal design below 200mm height
• Copeland scroll compliance for superior reliability
and efficiency
• Two oil-pumps
• Hermetic design for leak-free operation
• Wide operating envelope for heat pump and cooling
applications
• 25 - 100 Hz capacity modulation range for precise control and
increase of the seasonal performance
• IP56 terminal box

GPC-EN-2024 COMFORT APPLICATIONS 42


Operating envelope R407C Operating envelope R134a
Fixed speed Fixed speed
80 80

70 70
Condensing Temperature °C

Condensing Temperature °C
60 60

50 50

40 40

30 30

20 20

10 10

0 0
-35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 -10 -5 0 5 10 15 20 25
Evaporating Temperature °C Evaporating Temperature °C
R407C - 5K Superheat R134a - 5K Superheat
ZRH 72-81 KTE ZRH 87-116 KTE ZRH 72-81 KTE ZRH 87-116 KTE

Variable speed - ZRHV72 - 81KTE Variable speed - ZRHV72 - 81KTE


80 80

70 Condensing Temperature °C 70

60 60
Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-35 -25 -15 -5 5 15 25 -15 -10 -5 0 5 10 15 20 25

Evaporating Temperature °C Evaporating Temperature °C


R407C - 10K Superheat R134a - 10K Superheat
40-80 Hz (2400 - 4800 RPM) 40-80 Hz (2400 - 4800 RPM)
25-80 Hz (1500 - 2400 RPM) 30-80 Hz (1800 - 2400 RPM)
25-80 Hz (1500 - 2400 RPM)

Variable speed - ZRHV94KTE Variable speed - ZRHV*KTR/KTE


80 80

70 70

60 60
Condensing Temperature °C
Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-15 -10 -5 0 5 10 15 20 25 -15 -10 -5 0 5 10 15 20 25

Evaporating Temperature °C Evaporating Temperature °C


R407C - 10K Superheat R134a - 10K Superheat
40-80 Hz (2700 - 4800 RPM) 45-80 Hz (2700 - 4800 RPM)
30-80 Hz (2100 - 2700 RPM) 35-80 Hz (2100 - 2700 RPM)

43 GPC-EN-2024 COMFORT APPLICATIONS


Operating envelope R454C Operating envelope R513A

Variable speed - YRHV*KTE Variable speed - ZRHV72 - 81KTR


80 80

70 70

Condensing Temperature °C
60 60
Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-35 -25 -15 -5 5 15 25 -15 -10 -5 0 5 10 15 20 25

Evaporating Temperature °C Evaporating Temperature °C


R454C - 10K Superheat R513A - 10K Superheat
40-80 Hz 40-80 Hz (2400 - 4800 RPM)
40-100 Hz 30-80 Hz (1800 - 2400 RPM)
21-100Hz

GPC-EN-2024 COMFORT APPLICATIONS 44


Technical overview - fixed speed models

Stub Discharge
Motor Maximum Locked

@1 m - dB(A)**
Displacement

Stub Suction

Oil Quantity
Length/ Version/ Operating Rotor

Pressure
Nominal
Net

Sound
(m3/h)

(inch)

(inch)
Width/ Code Current (A) Current (A)

hp
Models Weight

(l)
Height
(kg)
(mm)
3 Ph* 3 Ph* 3 Ph*

ZRH72KTE/KTR 6.0 17.1 7/8 3/4 2.6 567/290/191 49 TFD 12 92 61


ZRH81KTE/KTR 6.8 18.8 7/8 3/4 2.7 567/290/191 49 TFD 12 92 61
ZRH87KTE/KTR 7.5 22.1 1 3/8 7/8 1.6 586/314/245 60 TFD 16 95 63
ZRH100KTE/KTR 9.0 24.9 1 /83
7/8 1.6 586/314/245 63 TFD 18 111 63
ZRH116KTE/KTR 10.0 29.1 1 3/8 7/8 1.6 586/314/245 64 TFD 20 118 63
YRH72KTE 6.0 17.1 7/8 3/4 2.6 567/291/191 49 TFD 12 92 61
YRH81KTE 6.8 18.8 7/8 3/4 2.7 567/291/191 49 TFD 13 92 61
Conditions: EN12900 - HT: Evaporating +5°C, Condensing +50°C, suction Superheat 10K, Subcooling 0K
*TFD: 3Ph 380-420V/50Hz - 460/60Hz; TF5 200-220V/50Hz, 200-230V/60Hz
** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data - fixed speed models


Condensing Temperature +50°C
Cooling Capacity (kW) Power Input (kW)
R407C R407C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -10 -5 0 +5 +10 +15 Model -10 -5 0 +5 +10 +15
ZRH72KTE 8.1 10.1 12.5 15.3 18.6 22.4 ZRH72KTE 4.8 4.8 4.8 4.83 4.9 5.0
ZRH81KTE 9.0 11.2 13.9 17.0 20.5 24.7 ZRH81KTE 5.2 5.2 5.3 5.3 5.4 5.4
ZRH87KTE 11.8 15.2 19.2 23.9 ZRH87KTE 6.2 6.3 6.3 6.3
ZRH100KTE 14.2 17.9 22.1 26.9 ZRH100KTE 6.8 6.9 7.0 7.0
ZRH116KTE 16.0 20.0 24.9 30.6 ZRH116KTE 8.1 8.2 8.2 8.2

Conditions: Suction Superheat 10K / Subcooling 0K

Condensing Temperature +50°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -10 -5 0 +5 +10 +15 Model -10 -5 0 +5 +10 +15
ZRH72KTE 6.8 8.5 10.4 12.7 15.3 ZRH72KTE 3.2 3.3 3.3 3.4 3.4
ZRH81KTE 7.6 9.5 11.7 14.2 17.0 ZRH81KTE 3.5 3.6 3.6 3.7 3.7
ZRH87KTE 8.0 10.3 13.0 16.2 20.0 ZRH87KTE 4.3 4.3 4.3 4.3 4.5
ZRH100KTE 9.6 12.1 15.0 18.3 22.1 ZRH100KTE 4.7 4.8 4.8 4.8 4.9
ZRH116KTE 10.9 13.6 16.9 20.7 25.0 ZRH116KTE 5.6 5.6 5.6 5.7 5.7
Conditions: Suction Superheat 10K / Subcooling 0K
Preliminary Data

Condensing Temperature +50°C


Cooling Capacity (kW) Power Input (kW)
R513A R513A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -10 -5 0 +5 +10 +15 Model -10 -5 0 +5 +10 +15
ZRH72KTR 6.9 8.6 10.6 12.9 15.5 ZRH72KTR 3.4 3.5 3.5 3.5 3.6
ZRH81KTR 7.7 9.7 11.9 14.4 17.3 ZRH81KTR 3.8 3.9 3.9 3.9 3.9
ZRH87KTR 8.6 10.9 13.5 16.6 ZRH87KTR 4.3 4.4 4.4 4.4
ZRH100KTR 10.0 12.5 15.4 18.8 ZRH100KTR 4.8 4.9 4.9 4.9
ZRH116KTR 11.8 14.8 18.2 22.1 ZRH116KTR 5.6 5.7 5.7 5.8
Conditions: Suction Superheat 10K / Subcooling 0K
Preliminary Data

Condensing Temperature +50°C


Cooling Capacity (kW) Power Input (kW)
R454C R454C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -10 -5 0 +5 +10 +15 Model -10 -5 0 +5 +10 +15
YRH72KTE 6.9 8.7 10.7 13.1 15.8 18.9 YRH72KTE 4.2 4.2 4.3 4.3 4.3 4.4
YRH81KTE 8.1 10.2 12.5 15.3 18.5 22.1 YRH81KTE 5.0 5.0 5.0 5.0 5.0 5.1
Conditions: Suction Superheat 10K / Subcooling 0K
Preliminary Data

45 GPC-EN-2024 COMFORT APPLICATIONS


Technical overview - variable speed models

@1 m - dB(A)**
Motor Maximum Locked

Displacement

Stub Suction
(m3/h) 50Hz

Oil Quantity
Capacity

discharge
Version/ Operating Rotor

pressure
Length/ Net

Sound
(kW)

(inch)

(inch)
Stub
Models EER Width/Height Weight Code Current (A) Current (A)

(l)
(mm) (kg)
Min 3 Ph* 3 Ph* 3 Ph*

YRHV72KTE 6.5 3.1 20.6 7/8 3/4 2.7 567/291/191 49 TX7 22 92 70

YRHV81KTE 6.8 3.1 22.6 7/8 3/4 2.7 567/291/191 49 TX7 26 92 70

ZRHV72KTE/KTR 7.2 3.1 20.6 7/8 3/4 2.7 567/291/191 49 TX7 22 92 70

ZRHV81KTE/KTR 7.6 3.1 22.6 7/8 3/4 2.7 567/291/191 49 TX7 26 92 70

ZRHV94KTE 17.4 3.1 26.7 1 3/8 7/8 1.6 586/314/245 60 TF7 24 145 73
Conditions: EN12900 R407C - HT: Evaporating +5°C, Condensing +50°C, Suction Superheat 10K,Subcooling 0K
**TF7 For VFD Control 380/3/75Hz V/F curve
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data - variable speed models


Condensing Temperature +50°C
Cooling Capacity (kW) Power Input (kW)
R407C R407C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -10 -5 0 +5 +10 +15 Model -10 -5 0 +5 +10 +15
Max 15.8 19.8 24.7 25.0 30.3 36.2 Max 11.0 11.2 11.3 8.2 8.3 8.3
ZRHV72KTE/KTR ZRHV72KTE/KTR
Min 5.9 4.7 5.9 7.2 8.7 17.0 Min 4.1 2.6 2.6 2.5 2.5 4.2
Max 18.0 22.3 27.4 25.9 31.1 37.1 Max 8.5 8.6 8.7 8.8 9.0 9.2
ZRHV81KTE/KTR ZRHV81KTE/KTR
Min 6.3 4.6 6.0 7.6 9.4 18.4 Min 4.6 3.1 3.1 3.0 3.0 4.5
Max 18.9 24.6 31.4 38.9 Max 10.0 10.5 10.6 10.8
ZRHV94KTE ZRHV94KTE
Min 7.8 10.1 12.9 15.9 Min 4.4 4.6 4.6 4.7
Conditions: Suction Superheat 10K / Subcooling 0K

Condensing Temperature +50°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -10 -5 0 +5 +10 +15 Model -10 -5 0 +5 +10 +15
Max 11.0 13.7 16.8 20.4 24.6 24.3 Max 5.5 5.6 5.6 5.7 5.7
ZRHV72KTE ZRHV72KTE
Min 3.1 3.9 4.8 5.8 11.4 11.4 Min 1.8 1.7 1.7 1.7 2.8
Max 12.4 15.5 19.0 23.1 27.8 24.9 Max 6.1 6.2 6.2 6.2 6.3
ZRHV81KTE ZRHV81KTE
Min 3.1 4.0 5.1 6.3 12.3 12.3 Min 2.1 2.1 2.0 2.0 3.0
Max 13.0 16.9 21.4 26.4 31.4 31.4 Max 6.9 7.2 7.3 7.5 8.0
ZRHV94KTE ZRHV94KTE
Min 8.0 6.7 8.8 10.9 12.9 12.9 Min 3.5 3.2 3.2 3.2 3.5
Conditions: Suction Superheat 10K / Subcooling 0K
Preliminary Data

Condensing Temperature +50°C


Cooling Capacity (kW) Power Input (kW)
R513A R513A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -10 -5 0 +5 +10 +15 Model -10 -5 0 +5 +10 +15
Max 13.8 16.5 19.3 23.0 26.4 Max 13.8 16.5 19.3 23.0 26.4
ZRHV72KTR ZRHV72KTR
Min 5.7 7.1 6.5 8.7 9.6 Min 5.7 7.1 6.5 8.7 9.6
Max 15.3 17.8 21.7 24.7 29.4 Max 15.3 17.8 21.7 24.7 29.4
ZRHV81KTR ZRHV81KTR
Min 6.2 7.8 7.2 8.8 10.6 Min 6.2 7.8 7.2 8.8 10.6
Conditions: Suction Superheat 10K / Subcooling 0K
Preliminary Data

Condensing Temperature +50°C


Cooling Capacity (kW) Power Input (kW)
R454C R454C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -10 -5 0 +5 +10 +15 Model -10 -5 0 +5 +10 +15
Max 15.5 19.1 23.4 26.4 31.1 34.8 Max 10.7 10.6 10.5 9.2 8.6 7.9
YRHV72KTE YRHV72KTE
Min 4.0 4.7 5.9 7.2 7.7 12.6 Min 3.0 2.6 2.5 2.4 2.3 2.9
Max 16.5 20.3 24.6 27.7 32.4 36.3 Max 10.3 10.2 10.1 9.8 9.4 8.7
YRHV81KTE YRHV81KTE
Min 4.0 4.7 6.1 7.6 9.3 14.5 Min 3.5 3.1 3.0 2.8 2.7 3.3

GPC-EN-2024 COMFORT APPLICATIONS 46


47 GPC-EN-2024 COMFORT APPLICATIONS
Refrigeration applications

GPC-EN-2024 REFRIGERATION APPLICATIONS 48


Refrigeration applications

Copeland offers a wide range of solutions for commercial Especially when compact equipment, energy efficiency
refrigeration applications. With its long-lasting expertise in and reliability are musts, scroll technology is the preferred
semi- hermetic reciprocating compressor technology as choice for refrigeration applications. With developments
well as in scroll technology, we can meet the requirements such as vapor injection and digital modulation, scroll has
for most applications - at the small end just like at the large become the leading technology and is widely recognized
end of commercial refrigeration. in the refrigeration market.

Completed by the various offerings in the segment of Whatever the chosen technology and product solution,
refrigeration units, Copeland is able to offer the best Copeland’s range meets the specific refrigeration
solution and performance, whether you are looking for needs covering the entire spectrum of medium and low
applications in foodservice or processing, supermarkets, temperature applications whether using standard HFCs,
hypermarkets, petrol stations or refrigerated warehousing. low GWP or natural refrigerants.

Copeland prime focus for its semi-hermetic reciprocating


technology is at the large end of commercial refrigeration.
Here aspects such as reliability, serviceability and capacity
modulation are of importance and they are perfectly
provided by Copeland semi-hermetic reciprocating
compressors. Innovations like Discus™ and Stream
technologies, digital modulation and Copeland
Compressor Electronics technology for advanced
protection and preventive maintenance keep semi-
hermetic at the forefront of compressor technology.

49 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland YB and YBD scroll compressor ranges for medium temperature
refrigeration for low GWP refrigerants classified as A2L

The standard and digital models from Copeland YB*K1E scroll series for
medium temperature applications feature an optimized design for F-Gas
compliant low GWP A2L refrigerants. The scroll compressor was optimized
internally and externally to create the most reliable compressor with
refrigerants with a high HFO content.

These compressors, available with displacements from 5.8 to 21.4 m3/h are
designed to provide seasonal efficiencies 15% higher than traditional semi-
hermetic compressors. These compressors are extremely quiet and can
be fitted with an external sound shell for an additional 10 - 12 dBA sound
reduction, which makes them best choice for refrigeration applications in
urban and domestic areas.

YB scroll compressor
YB & YBD scroll compressors line-up

YB

Digital YBD

Displacement (m3/h)
0 5 10 15 20 25 30

Features and benefits Maximum allowable pressure (PS)


• One model for multiple A2L refrigerants: R455A, R454A, R454C, • Low Side PS 23.5 bar (g)
as well as R1234yf for YB models. These compressors are also • High Side PS 38 bar (g)
designed to operate with previous A1 refrigerants:
R448A/R449A, R407A/F, R450A, R513A, R134a and R404A.
• Fully hermetic design to avoid risk of refrigerant leakage
• Flexibility in terms of required capacity: multiple design options
• Extremely quiet operation, specially adapted to applications in
urban and domestic areas
• Copeland scroll digital technology for simple, stepless 10 to
100% capacity modulation
• Light weight and compact design
• Wide operating envelope with 10°C low condensing limit

Operating envelopes

YB*1E - R455A YBD*1E - R455A


Condensing Temperature °C

Condensing Temperature °C

60 60

50 50

40 40

30 30

20 20

10 10

0 0
-30 -25 -20 -15 -10 -5 0 5 10 15 -30 -25 -20 -15 -10 -5 0 5 10 15
Evaporating Temperature °C Evaporating Temperature °C
10K Superheat 20°C Suction Gas Return 10K Superheat 20°C Suction Gas Return

GPC-EN-2024 REFRIGERATION APPLICATIONS 50


Operating envelopes

YB*1E - R454C YBD*1E - R454C

60
Condensing Temperature °C

60

Condensing Temperature °C
50 50

40 40

30 30

20 20

10 10

0 0

-30 -25 -20 -15 -10 -5 0 5 10 15 -30 -25 -20 -15 -10 -5 0 5 10 15
Evaporating Temperature °C Evaporating Temperature °C
10K Superheat 20°C Suction Gas Return 10K Superheat 20°C Suction Gas Return

YB*1E - R454A YBD*1E - R454A

60 60
Condensing Temperature °C
Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0

-30 -25 -20 -15 -10 -5 0 5 10 15 -30 -25 -20 -15 -10 -5 0 5 10 15
Evaporating Temperature °C Evaporating Temperature °C
10K Superheat 20°C Suction Gas Return 10K Superheat 20°C Suction Gas Return

YB*1E - R1234yf

60
Condensing Temperature °C

50

40

30

20

10

-30 -25 -20 -15 -10 -5 0 5 10 15


Evaporating Temperature °C
10K Suction Superheat
Maximum Evaporating Temperature

51 GPC-EN-2024 REFRIGERATION APPLICATIONS


Technical overview

Brazed Discharge
Brazed Suction

Oil Quantity (l)


Displacement
Maximum Sound
Length/ Motor Locked Rotor
Nominal Net Operating Pressure

(m3/h)

(inch)

(inch)
Width/ Version/Code Current (A)
hp
Models Weight Current (A) @1 m
Height
(kg) (dBA)
(mm)
***
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**

YB12K1E 2.0 5.8 3/4 1/2 1.3 253/248/365 24 PFZN TFMN 11 4 61 26 60

YB17K1E 2.5 8.0 3/4 1/2 1.5 253/248/387 28 PFZN TFMN 16 6 76 32 61

YB21K1E 3.5 10.0 3/4 1/2 1.5 253/248/401 29 PFZN TFMN 21 7 97 46 64

YB24K1E 4.0 11.4 3/4 1/2 1.5 253/248/417 29 PFZN TFMN 24 8 114 50 60

YB31K1E 5.0 14.3 7/8 1/2 1.9 255/261/442 38 TFMN 10 64 63

YB36K1E 6.0 16.7 7/8 1/2 1.9 255/261/442 39 TFMN 12 74 64

YB45K1E 8.0 21.4 7/8 1/2 1.9 255/261/442 44 TFMN 16 102 71

Digital Models

YBD17K1E 3.0 8.8 3/4 1/2 1.2 253/248/435 30 TFMN 7 40 58

YBD24K1E 4.0 11.4 7/8 1/2 1.4 253/248/466 30 TFMN 10 48 58

YBD31K1E 5.0 14.4 7/8 1/2 1.9 255/261/481 38 TFMN 11 64 67

YBD36K1E 6.0 17.1 7/8 1/2 1.9 255/261/481 40 TFMN 12 74 61

YBD45K1E 8.0 21.4 7/8 1/2 1.9 255/261/481 43 TFMN 16 102 68


* 1ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data
Condensing Temperature 40°C
Cooling Capacity (kW) Power Input (kW)
R455A R455A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
YB12K1E 1.7 2.2 2.7 3.3 4.0 YB12K1E 1.1 1.2 1.3 1.3 1.4
YB17K1E 2.5 3.1 3.8 4.6 5.6 YB17K1E 1.6 1.6 1.7 1.8 1.8
YB21K1E 3.1 3.9 4.8 5.8 7.0 YB21K1E 2.0 2.1 2.1 2.2 2.3
YB24K1E 3.6 4.4 5.4 6.5 7.9 YB24K1E 2.3 2.4 2.4 2.5 2.6
YB31K1E 4.4 5.5 6.8 8.2 10.0 YB31K1E 2.7 2.8 2.9 3.1 3.2
YB36K1E 5.2 6.5 8.0 9.7 11.8 YB36K1E 3.1 3.3 3.5 3.6 3.7
YB45K1E 6.7 8.3 10.1 12.3 14.9 YB45K1E 4.0 4.2 4.4 4.6 4.8
Digital Models
YBD17K1E 2.7 3.4 4.2 5.1 6.2 YBD17K1E 1.8 1.8 1.9 1.9 2.0
YBD24K1E 3.6 4.4 5.4 6.5 7.9 YBD24K1E 2.3 2.4 2.4 2.5 2.6
YBD31K1E 4.5 5.5 6.8 8.3 10.0 YBD31K1E 2.7 2.8 3.0 3.1 3.2
YBD36K1E 5.4 6.6 8.2 10.0 12.1 YBD36K1E 3.2 3.4 3.5 3.7 3.8
YBD45K1E 6.7 8.3 10.1 12.3 14.9 YBD45K1E 4.0 4.2 4.4 4.6 4.8

Conditions: Suction Gas Return 20°C / Subcooling 0K


Preliminary data

GPC-EN-2024 REFRIGERATION APPLICATIONS 52


Capacity data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R454C R454C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
YB12K1E 1.7 2.1 2.6 3.1 3.8 YB12K1E 1.1 1.1 1.2 1.2 1.3
YB17K1E 2.4 2.9 3.6 4.4 5.3 YB17K1E 1.5 1.5 1.6 1.6 1.7
YB21K1E 3.0 3.7 4.6 5.6 6.7 YB21K1E 1.9 1.9 2.0 2.1 2.1
YB24K1E 3.4 4.2 5.1 6.3 7.6 YB24K1E 2.1 2.2 2.3 2.3 2.4
YB31K1E 4.2 5.2 6.4 7.9 9.5 YB31K1E 2.5 2.6 2.7 2.8 3.0
YB36K1E 5.0 6.2 7.6 9.3 11.3 YB36K1E 2.9 3.1 3.2 3.3 3.5
YB45K1E 6.3 7.8 9.7 11.8 14.3 YB45K1E 3.8 4.0 4.1 4.3 4.4
Digital Models
YBD17K1E 2.6 3.2 4.0 4.8 5.9 YBD17K1E 1.7 1.7 1.7 1.8 1.8
YBD24K1E 3.4 4.2 5.1 6.3 7.6 YBD24K1E 2.1 2.2 2.3 2.3 2.4
YBD31K1E 4.2 5.3 6.5 7.9 9.6 YBD31K1E 2.5 2.7 2.8 2.9 3.0
YBD36K1E 5.1 6.3 7.8 9.5 11.5 YBD36K1E 3.0 3.1 3.3 3.4 3.5
YBD45K1E 6.3 7.8 9.7 11.8 14.3 YBD45K1E 3.8 4.0 4.1 4.3 4.4
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R454A R454A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
YB12K1E 2.0 2.5 3.0 3.7 4.5 YB12K1E 1.3 1.3 1.4 1.5 1.5
YB17K1E 2.8 3.4 4.2 5.2 6.2 YB17K1E 1.8 1.8 1.9 1.9 2.0
YB21K1E 3.5 4.4 5.4 6.6 8.0 YB21K1E 2.2 2.3 2.4 2.4 2.5
YB24K1E 3.9 4.9 6.0 7.3 8.9 YB24K1E 2.5 2.6 2.7 2.8 2.9
YB31K1E 4.9 6.2 7.6 9.3 11.2 YB31K1E 3.0 3.1 3.3 3.4 3.5
YB36K1E 5.8 7.3 9.0 11.0 13.3 YB36K1E 3.5 3.7 3.8 4.0 4.1
YB45K1E 7.4 9.2 11.4 13.9 16.8 YB45K1E 4.5 4.7 4.9 5.1 5.3
Digital Models
YBD17K1E 3.1 3.8 4.7 5.7 6.9 YBD17K1E 2.0 2.0 2.1 2.1 2.2
YBD24K1E 3.9 4.9 6.0 7.3 8.9 YBD24K1E 2.5 2.6 2.7 2.8 2.9
YBD31K1E 5.0 6.2 7.6 9.3 11.3 YBD31K1E 3.0 3.1 3.3 3.4 3.5
YBD36K1E 5.9 7.5 9.2 11.3 13.6 YBD36K1E 3.6 3.7 3.9 4.1 4.2
YBD45K1E 7.4 9.2 11.4 13.9 16.8 YBD45K1E 4.5 4.7 4.9 5.1 5.3
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R1234yf R1234yf
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
YB12K1E 1.2* 1.8 2.2 2.6 YB12K1E 0.8* 0.8 0.9 0.9
YB17K1E 1.8* 2.5 3.0 3.7 YB17K1E 1.1* 1.1 1.2 1.2
YB21K1E 2.2* 3.2 3.9 4.7 YB21K1E 1.4* 1.4 1.5 1.5
YB24K1E 2.5* 3.6 4.3 5.3 YB24K1E 1.6* 1.6 1.7 1.7
YB31K1E 3.2* 4.5 5.5 6.6 YB31K1E 1.9* 1.9 2.0 2.1
YB36K1E 3.7* 5.2 6.4 7.8 YB36K1E 2.2* 2.3 2.4 2.5
YB45K1E 4.8* 6.7 8.2 9.9 YB45K1E 2.8* 2.9 3.0 3.2
Digital Models
YBD17K1E 1.9* 2.7 3.4 4.1 YBD17K1E 1.2* 1.2 1.3 1.3
YBD24K1E 2.5* 3.6 4.3 5.3 YBD24K1E 1.6* 1.6 1.7 1.7
YBD31K1E 3.2* 4.5 5.5 6.7 YBD31K1E 1.9* 1.9 2.0 2.1
YBD36K1E 3.8* 5.3 6.5 7.9 YBD36K1E 2.2* 2.3 2.4 2.5
YBD45K1E 4.8* 6.7 8.2 9.9 YBD45K1E 2.8* 2.9 3.0 3.2
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary data
*Conditions: Suction Superheat 10K, Subcooling 0K

53 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland ZB and ZBD scroll compressor ranges for
medium temperature refrigeration using R407A/F/C, R448A/
R449A, R404A, R134a, R450A and R513A

Copeland offers ZB compressors with a wide displacement range


from 5.9 m3/h to 87.5 m3/h. It includes ZBD digital compressors
models that offer continuous capacity modulation technology.

Copeland scroll compressors have 3 times less moving parts


than reciprocating compressors and feature a scroll compliance
mechanism which makes them particularly robust and reliable under
severe conditions including liquid slugging.

They have the advantage of light weight and compactness, making


them ideal for the usage in refrigeration units, compact refrigeration
systems or special process units.

The summit series from 7 to 15 hp is designed to provide seasonal ZB compressor for


efficiencies 15% higher than traditional semi-hermetic compressors. medium temperature refrigeration
These compressors are extremely quiet and can be fitted with an with and without sound shell
external sound shell for an additional 10 dBA sound reduction.

ZBD digital scroll compressors

Based on the unique Copeland compliant scroll design, the digital


modulation operates on a simple mechanism. Capacity control is
achieved by separating the scroll sets axially over a small period of
time. It is a simple mechanical solution allowing precise temperature
control and system efficiency and it requires no other components.

Digital scroll technology provides continuous, stepless modulation


from 10% to 100% with no operating envelope restriction. As a result,
system pressures and temperatures are tightly controlled. These
compressors provide optimum performance for refrigeration units,
refrigeration packs, process and agricultural units.

ZB and ZBD compressor line-up

Digital ZBD

ZB

Displacement (m3/h)
0 5 10 15 20 25 30 35 40 45
50

Features and benefits Maximum allowable pressure (PS)

• Copeland scroll axial and radial compliance for superior • ZB15 to ZB45:
reliability and efficiency Low Side PS 21 bar(g) / High Side PS 32 bar(g)
• ZB50 to ZB114:
• Wide operating envelope with 10°C condensing limit and
Low Side PS 22.6 bar(g) / High Side PS 32 bar(g)
fast pull-down capabilities
• Digital ZBD:
• High seasonal efficiencies as scrolls are designed at the Low Side PS 21 bar(g) / High Side PS 28.8 bar(g)
condition where equipment runs most of the time • Summit ZBD:
• Light weight and compactness, up to half the weight of Low Side PS 22.6 bar(g) / High Side PS 32 bar (g)
equivalent semi-hermetic compressors
• Availability of optional sound shell on all models providing
an additional 10 dBA sound attenuation for silent operation
• Includes 12 digital scroll compressor models for simple,
stepless 10 to 100% capacity modulation
• One model for multiple refrigerants R407A/F/C, R448A/
R449A, R404A, R134a, R450A and R513A

GPC-EN-2024 REFRIGERATION APPLICATIONS 54


Operating envelope

ZB - R448A/R449A ZBD - R134a


70 80

70
60
Condensing Temperature °C

Condensing Temperature °C
60
50
50

40 40

30
30

20
20
10
10
0

0
-30 -25 -20 -15 -10 -5 0 5 10 15 -20 -15 -10 -5 0 5 10 15 20
Evaporating Temperature °C Evaporating Temperature °C
20°C Suction Gas Return 10K Superheat 10K Superheat

ZB - R407A ZB - R134a
70 80

70
60
Condensing Temperature °C

Condensing Temperature °C

60
50
50

40 40

30
30

20
20
10

10
0

0
-30 -25 -20 -15 -10 -5 0 5 10 15 -20 -15 -10 -5 0 5 10 15 20
Evaporating Temperature °C Evaporating Temperature °C
20°C Suction Gas Return 10K Superheat 20°C Suction Gas Return 10K Superheat

55 GPC-EN-2024 REFRIGERATION APPLICATIONS


Technical overview

@1 m - dB(A)***
Discharge (inch)

Net Weight (kg)

Sound Pressure
Oil Quantity (l)
Displacement

suction (inch)
Maximum
Motor Locked Rotor

Rotalock

Rotalock
Nominal
Operating

(m3/h)
Length/Width/ Version/Code Current (A)
hp
Models Current (A)
Height (mm)

1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**

ZB15KCE 2.0 5.9 1 /4 1


1 1.3 241/241/369 25 PFJ TFD 12 4 58 26 55
ZB19KCE 2.5 6.8 1 1/4 1 1.5 242/242/369 27 PFJ TFD 12 6 61 32 55
ZB21KCE 3.0 8.6 1 /4 1
1 1.2 243/244/391 29 PFJ TFD 16 7 82 40 58
ZB26KCE 3.5 10.0 1 1/4 1 1.5 243/244/405 28 PFJ TFD 18 8 97 46 60
ZB29KCE 4.0 11.4 1 /4 1
1 1.5 246/246/423 29 TFD 10 50 58
ZB38KCE 5.0 14.4 1 /4 1
1 1.9 242/242/438 37 PFJ TFD 32 12 142 65 61
ZB42KCE 5.5 16.2 1 1/4 1 1.9 251/246/438 43 PFJ 35 150 62
ZB45KCE 6.0 17.1 1 /4 1
1 1.9 242/242/438 39 TFD 13 74 61
ZB48KCE 6.5 18.8 1 1/4 1 1/4 1.8 246/250/442 39 TFD 14 101 62
ZB57KCE 21.4 1 /4 1
1 /4 1
1.9 246/256/442 39 TFD 15 102 68
ZB Summit Models
ZB66K5E 10.0 25.7 1 3/4 1 1/4 3.4 280/280/534 60 TFD 17 111 66
ZB76K5E 12.0 28.8 1 3/4 1 1/4 3.4 280/280/534 61 TFD 20 118 67
ZB95K5E 13.0 36.4 1 /4 3
1 /4 1
3.4 280/280/552 65 TFD 28 140 69
ZB114K5E 15.0 43.4 1 /4 3
1 /4 1
3.4 280/280/552 66 TFD 33 174 72
Digital Models
ZBD21KCE 3.0 8.3 1 1/4 1 1.2 243/243/432 30 PFJ TFD 16 6 97 40 62
ZBD29KCE 4.0 11.4 1 1/4 1 1.4 245/243/463 32 TFD 7 48 58
ZBD38KCE 5.0 14.4 1 1/4 1 1.9 246/250/481 38 TFD 11 64 67
ZBD45KCE 6.0 17.1 1 1/4 1 1.9 241/246/481 39 TFD 12 74 61
ZBD57KCE 7.5 21.4 1 /4 1
1 /4 1
1.9 246/257/481 43 TFD 15 102 68
ZBD76K5E 10.0 28.8 1 3/4 1 1/4 3.4 299/280/534 61 TFD 24 118 66
ZBD114K5E 15.0 43.3 1 /4 3
1 /4 1
3.4 299/280/552 68 TFD 33 174 71
* 1Ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

GPC-EN-2024 REFRIGERATION APPLICATIONS 56


Capacity data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
ZB15KCE 2.1* 2.8 3.5 4.2 ZB15KCE 1.5* 1.5 1.5 1.5
ZB19KCE 2.4* 3.2 4.0 5.0 ZB19KCE 1.5* 1.6 1.6 1.6
ZB21KCE 3.0* 4.0 5.1 6.3 ZB21KCE 2.0* 2.0 2.0 2.1
ZB26KCE 3.6* 4.7 5.8 7.1 ZB26KCE 2.3* 2.3 2.3 2.4
ZB29KCE 5.3 6.5 8.0 ZB29KCE 2.6 2.6 2.6
ZB38KCE 5.4* 7.2 8.9 11.0 ZB38KCE 3.2* 3.3 3.3 3.4
ZB42KCE** 6.1* 7.9 9.8 12.0 ZB42KCE** 3.9* 3.9 3.9 3.9
ZB45KCE 6.3* 8.2 10.2 12.4 ZB45KCE 3.9* 4.0 4.0 4.0
ZB48KCE 9.5 11.7 14.3 ZB48KCE 4.5 4.6 4.5
ZB57KCE 8.2* 10.6 13.1 15.8 ZB57KCE 4.4* 4.6 4.8 4.9
ZB Summit Models
ZB66K5E 9.2* 12.4 15.6 19.3 ZB66K5E 5.5* 5.5 5.7 5.8
ZB76K5E 10.6* 14.2 18.1 22.4 ZB76K5E 6.5* 6.5 6.7 6.9
ZB95K5E 12.9* 17.7 22.5 27.8 ZB95K5E 8.3* 8.3 8.5 8.7
ZB114K5E 14.8* 20.5 26.3 32.8 ZB114K5E 10.2* 10.2 10.3 10.5
Digital Models
ZBD21KCE 3.4* 4.3 5.2 6.3 ZBD21KCE 1.8* 1.9 1.9 2.0
ZBD29KCE 4.2* 5.5 6.8 8.4 ZBD29KCE 2.6* 2.6 2.6 2.6
ZBD38KCE 5.5* 7.3 9.1 11.2 ZBD38KCE 3.4* 3.4 3.4 3.5
ZBD45KCE 6.1* 8.1 10.1 12.5 ZBD45KCE 3.8* 3.8 3.8 3.9
ZBD57KCE 8.4* 11.1 13.8 17.0 ZBD57KCE 5.2* 5.2 5.3 5.3
ZBD76K5E 8.2* 11.3 14.5 18.4 22.8 ZBD76K5E 7.5* 7.1 7.1 7.3 7.5
ZBD114K5E 10.8* 15.6 20.5 26.3 32.8 ZBD114K5E 10.3* 10.2 10.2 10.3 10.5
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K
** Single Phase Only
Preliminary Data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R407F R407F
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
ZB15KCE 2.6* 3.4 4.2 ZB15KCE 1.6* 1.6 1.6
ZB19KCE 3.2* 4.2 5.1 ZB19KCE 1.9* 1.9 1.9
ZB21KCE 3.9* 5.0 6.2 ZB21KCE 2.2* 2.2 2.3
ZB26KCE 4.5* 5.8 7.2 ZB26KCE 2.6* 2.6 2.6
ZB29KCE 5.4* 7.0 8.7 ZB29KCE 2.8* 2.9 2.8
ZB38KCE 5.2* 6.9* 8.9 11.0 ZB38KCE 3.7* 3.7* 3.7 3.7
ZB42KCE** 5.9* 7.8* 10.1 12.5 ZB42KCE** 4.0* 4.0* 4.0 4.1
ZB45KCE 6.0* 8.1* 10.5 13.0 ZB45KCE 4.1* 4.2* 4.3 4.2
ZB48KCE 7.0* 9.3* 12.1 15.0 ZB48KCE 4.7* 4.8* 4.9 4.9
ZB57KCE 8.5* 10.9* 13.8 16.9 ZB57KCE 5.0* 5.1* 5.1 5.2
ZB Summit Models
ZB66K5E 9.5* 13.0* 16.9 20.9 ZB66K5E 5.8* 5.8* 5.9 6.1
ZB76K5E 10.9* 14.9* 19.6 24.2 ZB76K5E 6.9* 6.8* 7.0 7.2
ZB95K5E 13.2* 18.6* 24.4 30.1 ZB95K5E 8.7* 8.8* 8.9 9.1
ZB114K5E 15.2* 21.5* 28.5 35.4 ZB114K5E 10.6* 10.7* 10.8 11.0
Digital Models
ZBD21KCE 5.1 6.3 ZBD21KCE 2.0 2.0
ZBD29KCE 5.8* 7.3 8.9 ZBD29KCE 2.9* 2.9 2.9
ZBD38KCE 5.7* 7.1* 8.9 10.8 ZBD38KCE 3.0* 3.3* 3.5 3.6
ZBD45KCE 6.4* 8.4* 10.8 13.2 ZBD45KCE 3.7* 3.9* 4.1 4.3
ZBD57KCE 8.5* 10.8* 13.8 17.0 ZBD57KCE 5.2* 5.2* 5.3 5.3
ZBD76K5E 11.5* 15.2 19.3 23.9 ZBD76K5E 7.5* 7.4 7.6 7.9
ZBD114K5E 15.8* 21.5 27.6 34.4 ZBD114K5E 10.7* 10.7 10.8 11.0
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K
** Single Phase Only
Preliminary Data

57 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Condensing Temperature 40°C


R448A/ Cooling Capacity (kW) R448A/ Power Input (kW)
R449A Evaporating Temperature (°C) R449A Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
ZB15KCE 1.6* 2.2 2.9 3.6 4.4 ZB15KCE 1.6* 1.5 1.5 1.5 1.4
ZB19KCE 2.0* 2.6 3.3 4.1 5.1 ZB19KCE 1.6* 1.6 1.6 1.6 1.6
ZB21KCE 2.4* 3.3 4.2 5.2 6.4 ZB21KCE 2.1* 2.1 2.1 2.1 2.1
ZB26KCE 2.6* 3.8 4.8 5.9 7.2 ZB26KCE 2.4* 2.4 2.4 2.4 2.4
ZB29KCE 3.3* 4.5 5.5 6.8 8.3 ZB29KCE 2.6* 2.6 2.6 2.7 2.7
ZB38KCE 3.9* 5.7 7.2 8.9 10.9 ZB38KCE 3.4* 3.4 3.4 3.4 3.4
ZB42KCE** 4.4* 6.4 8.1 10.1 12.3 ZB42KCE** 3.9* 3.9 3.9 3.9 3.9
ZB45KCE 4.5* 6.6 8.5 10.5 12.8 ZB45KCE 3.9* 3.9 3.9 3.9 3.9
ZB48KCE 5.3* 7.6 9.7 12.1 14.7 ZB48KCE 4.5* 4.5 4.5 4.5 4.5
ZB57KCE 6.4* 8.6 10.8 13.4 16.4 ZB57KCE 4.4* 4.5 4.7 4.9 5.1
ZB Summit Models
ZB66K5E 6.8* 9.4* 12.6 15.8 19.3 ZB66K5E 5.8* 5.8* 5.8 5.8 5.8
ZB76K5E 8.0* 11.1* 14.9 18.6 22.7 ZB76K5E 6.5* 6.6* 6.6 6.6 6.7
ZB95K5E 8.8* 13.2* 18.2 22.8 27.8 ZB95K5E 8.6* 8.6* 8.6 8.6 8.7
ZB114K5E 10.5* 15.5* 21.5 27.3 33.7 ZB114K5E 10.4* 10.3* 10.3 10.3 10.4
Digital Models
ZFD13KVE EVI 3.3 4.2 5.2 6.3 7.6 9.0 10.6 ZFD13KVE EVI 2.3 2.3 2.4 2.5 2.7 2.8 2.8
ZFD18KVE EVI 4.8 6.0 7.4 9.0 10.8 12.9 15.2 ZFD18KVE EVI 3.4 3.6 3.8 4.0 4.3 4.5 4.7
ZFD25KVE EVI 6.2 7.7 9.5 11.4 13.5 15.7 18.1 ZFD25KVE EVI 3.9 4.2 4.5 4.8 5.1 5.3 5.5
ZFD41K5E 7.4 9.4 11.8 14.6 17.9 21.7 26.2 ZFD41K5E 5.4 5.8 6.2 6.8 7.4 8.1 8.9
ZFD41K5E EVI 9.9 12.5 15.6 19.0 22.8 27.9 31.9 ZFD41K5E EVI 6.8 7.3 7.8 8.4 9.0 9.7 10.4
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K
** Single Phase Only
Preliminary Data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R404A R404A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
ZB15KCE 1.9 2.4 3.0 3.7 4.5 ZB15KCE 1.7 1.7 1.6 1.6 1.5
ZB19KCE 2.3 2.9 3.5 4.2 5.1 ZB19KCE 1.9 1.9 1.9 1.9 1.9
ZB21KCE 3.0 3.7 4.5 5.5 6.6 ZB21KCE 2.2 2.2 2.2 2.2 2.2
ZB26KCE 3.5 4.3 5.3 6.4 7.6 ZB26KCE 2.6 2.6 2.6 2.6 2.6
ZB29KCE 4.0 4.9 6.0 7.2 8.6 ZB29KCE 2.9 2.9 2.9 2.9 2.9
ZB38KCE 5.1 6.3 7.7 9.3 11.2 ZB38KCE 3.8 3.8 3.8 3.8 3.8
ZB42KCE** 5.7 7.1 8.7 10.6 12.7 ZB42KCE** 4.2 4.2 4.2 4.2 4.2
ZB45KCE 6.0 7.4 9.1 11.0 13.2 ZB45KCE 4.3 4.3 4.3 4.3 4.3
ZB48KCE 6.9 8.6 10.5 12.7 15.2 ZB48KCE 4.9 4.9 4.9 4.9 4.9
ZB57KCE 7.9 9.7 11.9 14.3 17.1 ZB57KCE 4.7 4.9 5.2 5.4 5.5
ZB Summit Models
ZB66K5E 9.1 11.4 13.9 16.8 20.1 ZB66K5E 6.2 6.2 6.2 6.3 6.4
ZB76K5E 10.5 13.1 16.2 19.7 23.6 ZB76K5E 7.2 7.2 7.3 7.4 7.5
ZB95K5E 10.7* 16.0 20.1 24.5 29.3 ZB95K5E 9.3* 9.2 9.3 9.3 9.4
ZB114K5E 12.5* 18.7 23.4 28.7 34.7 ZB114K5E 11.3* 11.3 11.3 11.4 11.4
Digital Models
ZFD13KVE EVI 4.0 4.9 6.0 7.2 8.5 10.0 11.7 ZFD13KVE EVI 2.9 3.0 3.1 3.2 3.3 3.4 3.5
ZFD18KVE EVI 6.1 7.3 8.7 10.4 12.3 14.4 16.9 ZFD18KVE EVI 4.0 4.3 4.5 4.6 4.8 5.0 5.1
ZFD25KVE EVI 7.7 9.3 11.2 13.2 15.3 17.5 19.7 ZFD25KVE EVI 4.8 5.1 5.4 5.7 6.0 6.3 6.6
ZFD41K5E EVI 12.5 15.0 18.1 21.5 25.4 29.5 33.9 ZFD41K5E EVI 7.9 8.4 8.8 9.3 9.7 10.1 10.6
ZFD41K5E 8.6 10.6 13.0 15.7 18.9 22.6 27.0 ZFD41K5E 6.3 6.7 7.1 7.5 7.9 8.4 8.8
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K
** Single Phase Only

GPC-EN-2024 REFRIGERATION APPLICATIONS 58


Capacity data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
ZB15KCE 1.4 1.7 2.2 2.7 ZB15KCE 0.9 0.9 0.9 0.9
ZB19KCE 1.6 2.0 2.5 3.1 ZB19KCE 1.1 1.1 1.1 1.1
ZB21KCE 2.0 2.5 3.2 4.0 ZB21KCE 1.3 1.3 1.3 1.3
ZB26KCE 2.3 2.9 3.7 4.6 ZB26KCE 1.5 1.5 1.5 1.5
ZB29KCE 2.5 3.2 4.0 5.0 ZB29KCE 1.7 1.7 1.7 1.7
ZB38KCE 3.2 4.2 5.4 6.7 ZB38KCE 2.1 2.1 2.1 2.2
ZB42KCE** 3.8 4.8 6.0 7.5 ZB42KCE** 2.5 2.5 2.5 2.4
ZB45KCE 4.0 5.1 6.4 8.0 ZB45KCE 2.4 2.4 2.5 2.5
ZB48KCE 4.8 6.0 7.5 9.1 ZB48KCE 2.8 2.8 2.9 2.9
ZB57KCE 5.0 6.4 8.1 10.1 ZB57KCE 3.4 3.4 3.4 3.5
ZB Summit Models
ZB66K5E 6.0 7.5 9.5 11.8 ZB66K5E 3.8 3.7 3.8 3.8
ZB76K5E 6.9 8.6 10.8 13.5 ZB76K5E 4.4 4.4 4.4 4.5
ZB95K5E 8.2 10.8 13.8 17.1 ZB95K5E 5.4 5.5 5.5 5.6
ZB114K5E 9.6 12.7 16.3 20.4 ZB114K5E 6.6 6.6 6.7 6.7
Digital Models
ZBD21KCE 2.0* 2.7 3.3 4.0 ZBD21KCE 1.2* 1.3 1.4 1.4
ZBD29KCE 2.5* 3.3 4.2 5.2 ZBD29KCE 1.7* 1.7 1.7 1.7
ZBD38KCE 3.2* 4.4 5.5 6.8 ZBD38KCE 1.9* 2.1 2.2 2.3
ZBD45KCE 3.8* 5.1 6.4 7.9 ZBD45KCE 2.3* 2.4 2.5 2.6
ZBD57KCE 4.7* 6.4 8.1 10.1 ZBD57KCE 3.4* 3.4 3.4 3.5
ZBD76K5E* 6.2 7.9 10.0 12.6 ZBD76K5E 5.3 5.3 5.4 5.4
ZBD114K5E* 8.1 11.1 14.6 18.7 ZBD114K5E 7.4 7.4 7.4 7.5
*Conditions: Suction Superheat 10K, Subcooling 0K
** Single Phase Only

59 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland YF, YFI and YFJ scroll compressor ranges for low temperature
refrigeration for Low GWP refrigerants classified as A2L

Copeland YF scroll compressors for low temperature applications feature an optimized


design for F-Gas compliant low GWP A2L refrigerants. The scroll compressor was optimized
internally and externally to create the most reliable compressor with refrigerants with a high
HFO content.

The range consists of:


• YF*K1E models that operate with liquid injection in order to control discharge temperature
and increase the operating envelope.
• YFI*K1E models that operate with vapor injection. This boosts the refrigeration system
cooling capacity and efficiency.
• YFJ*K1E models that operate with digital capacity modulation and vapor injection.
Capacity control is achieved by separating the scroll sets axially over a small period of
time. It is a simple mechanical solution allowing precise temperature control and system
efficiency and it requires no other components.

These compressors, available with displacements from 5.9 to 25.1 m3/h are designed to YF scroll compressor
provide seasonal efficiencies 15% higher than traditional semi-hermetic compressors.
These compressors are extremely quiet and can be fitted with an external sound shell for
an additional 10 - 12 dBA sound reduction, which makes them best choice for refrigeration
applications in urban and domestic areas.

YF, YFI and YFJ scroll compressors line-up

YF
YFI with vapor injection
YFJ digital
Displacement (m3/h)
0 5 10 15 20 25

Features and benefits

• One model for multiple refrigerants: R455A, R454A, R454C


• Fully hermetic design to avoid risk of refrigerant leakage
• Flexibility in terms of required capacity: multiple design options
• Extremely quiet operation, specially adapted to applications in
urban and domestic areas
• Light weight and compact design

Maximum allowable pressure (PS)

• Low Side PS 23.5 bar (g)


• High Side PS 38 bar (g)

GPC-EN-2024 REFRIGERATION APPLICATIONS 60


Operating envelope

YF*1E - R454A YFJ*1E - R454A


tc (°C) tc (°C)

60 60
Condensing Temperature °C

Condensing Temperature °C
50 50

40 40

30 30

20 20

10 10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10
Evaporating Temperature °C Evaporating Temperature °C
20°C Suction Gas Return Liquid Injection 20°C Suction Gas Return Liquid Injection

YF*1E - R454C YFJ*1E - R454C


tc (°C) tc (°C)

60 60
Condensing Temperature °C

Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10
Evaporating Temperature °C Evaporating Temperature °C
20°C Suction Gas Return Liquid Injection 20°C Suction Gas Return Liquid Injection

YF*1E - R455A YFJ*1E - R455A


tc (°C) tc (°C)

60 60
Condensing Temperature °C

Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10
Evaporating Temperature °C Evaporating Temperature °C
20°C Suction Gas Return Liquid Injection 20°C Suction Gas Return Liquid Injection

61 GPC-EN-2024 REFRIGERATION APPLICATIONS


Technical overview
Maximum Locked
Length/ Motor Sound
Rotalock Rotalock Oil Net Version/ Code Operating Rotor
Nominal Displacement Width/ Current (A) Current (A) Pressure
Models Suction Discharge Quantity Weight
hp (m /h)
3
Height @1 m -
(inch) (inch) (l) (kg)
(mm) 3 Ph** 3 Ph** 3 Ph** db(A)***

Models with Liquid Injection


YF05K1E 2.0 5.9 3/4 1/2 1.3 253/248/369 25 TFD 5 26 58
YF06K1E 2.5 7.3 3/4 1/2 1.5 253/248/391 26 TFD 6 32 58
YF07K1E 2.8 8.0 3/4 1/2 1.5 253/248/391 28 TFD 6 40 60
YF09K1E 3.5 9.9 3/4 1/2 1.5 253/248/405 29 TFD 7 46 60
YF10K1E 4.0 11.7 7/8 1/2 1.9 258/263/442 37 TFD 8 52 60
YF13K1E 5.0 14.4 7/8 1/2 1.9 258/263/442 40 TFD 10 64 60
YF15K1E 6.0 17.1 7/8 1/2 1.9 258/263/442 40 TFD 13 74 62
YF19K1E 7.5 21.4 7/8 3/4 1.9 258/263/442 44 TFD 16 102 67
Models with Vapor Injection
YFI10K1E 4.0 11.7 7/8 1/2 1.9 258/263/442 38 TFD 9 64 63
YFI15K1E 6.0 17.1 7/8 1/2 1.9 258/263/442 40 TFD 14 74 67
YFI19K1E 7.5 21.4 7/8 3/4 1.9 255/261/442 44 TFD 16 102 70
Digital Models with Vapor Injection
YFJ10K1E 4.0 11.7 7/8 1/2 1.9 258/263/481 40 TFD 9 64 63
YFJ15K1E 6.0 17.1 7/8 1/2 1.9 258/263/481 41 TFD 14 74 67
YFJ19K1E 7.5 21.4 7/8 3/4 1.9 258/263/481 46 TFD 16 102 70
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data
Condensing Temperature 40°C
Cooling Capacity (kW) Power Input (kW)
R455A R455A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Models with Liquid injection
YF05K1E 1.1 1.5 1.8 2.3 2.8 3.4 4.1 YF05K1E 1.1 1.1 1.2 1.3 1.3 1.4 1.5
YF06K1E 1.5 1.9 2.4 2.9 3.6 4.3 5.2 YF06K1E 1.2 1.3 1.3 1.4 1.4 1.5 1.5
YF07K1E 1.6 2.1 2.6 3.2 3.9 4.7 5.7 YF07K1E 1.3 1.4 1.4 1.5 1.6 1.6 1.7
YF09K1E 2.0 2.5 3.2 3.9 4.8 5.9 7.1 YF09K1E 1.6 1.7 1.8 1.9 1.9 2.0 2.1
YF10K1E 2.4 3.0 3.8 4.7 5.7 6.9 8.3 YF10K1E 1.9 2.0 2.1 2.2 2.3 2.4 2.5
YF13K1E 2.9 3.7 4.6 5.7 6.9 8.5 10.2 YF13K1E 2.3 2.4 2.6 2.7 2.8 2.9 3.0
YF15K1E 3.4 4.3 5.4 6.7 8.2 10.0 12.0 YF15K1E 2.8 2.9 3.0 3.1 3.3 3.4 3.5
YF19K1E 4.3 5.4 6.7 8.3 10.2 12.4 14.9 YF19K1E 3.4 3.6 3.7 3.9 4.1 4.2 4.4
Models with Vapor Injection
YFI10K1E 3.4 4.2 5.2 6.3 7.5 8.9 10.5 YFI10K1E 2.3 2.4 2.5 2.6 2.7 2.8 2.9
YFI15K1E 5.0 6.2 7.6 9.1 11.0 13.0 15.3 YFI15K1E 3.3 3.5 3.6 3.7 3.9 4.0 4.2
YFI19K1E 6.2 7.7 9.5 11.5 13.7 16.3 19.1 YFI19K1E 4.1 4.3 4.5 4.7 4.9 5.0 5.2
Digital Models with Vapor Injection
YFJ10K1E 3.4 4.2 5.2 6.3 7.5 8.9 10.5 YFJ10K1E 2.3 2.4 2.5 2.6 2.7 2.8 2.9
YFJ15K1E 5.0 6.2 7.6 9.1 11.0 13.0 15.3 YFJ15K1E 3.3 3.5 3.6 3.7 3.9 4.0 4.2
YFJ19K1E 6.2 7.7 9.5 11.5 13.7 16.3 19.1 YFJ19K1E 4.1 4.3 4.5 4.7 4.9 5.0 5.2
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 62


Capacity data
Condensing Temperature 40°C
Cooling Capacity (kW) Power Input (kW)
R454C R454C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Models with Liquid injection
YF05K1E 1.1 1.4 1.7 2.1 2.6 3.2 3.8 YF05K1E 1.0 1.0 1.1 1.1 1.2 1.3 1.4
YF06K1E 1.4 1.7 2.1 2.7 3.3 4.0 4.8 YF06K1E 1.1 1.2 1.3 1.3 1.4 1.5 1.5
YF07K1E 1.5 1.9 2.3 2.9 3.6 4.4 5.3 YF07K1E 1.2 1.3 1.4 1.4 1.5 1.6 1.7
YF09K1E 1.8 2.3 2.9 3.6 4.4 5.4 6.5 YF09K1E 1.5 1.5 1.6 1.7 1.8 1.9 1.9
YF10K1E 2.2 2.8 3.4 4.2 5.2 6.4 7.7 YF10K1E 1.7 1.8 1.9 2.0 2.1 2.2 2.3
YF13K1E 2.7 3.4 4.2 5.2 6.3 7.7 9.3 YF13K1E 2.1 2.2 2.3 2.4 2.5 2.6 2.7
YF15K1E 3.2 4.0 5.0 6.1 7.5 9.1 11.0 YF15K1E 2.5 2.6 2.7 2.8 2.9 3.0 3.2
YF19K1E 4.0 5.0 6.2 7.6 9.3 11.3 13.5 YF19K1E 3.0 3.2 3.3 3.5 3.6 3.7 3.9
Models with Vapor Injection
YFI10K1E 3.2 4.0 4.9 6.0 7.1 8.5 9.9 YFI10K1E 2.1 2.2 2.3 2.4 2.5 2.6 2.7
YFI15K1E 4.7 5.8 7.2 8.7 10.4 12.4 14.5 YFI15K1E 3.1 3.3 3.4 3.6 3.7 3.8 4.0
YFI19K1E 5.8 7.3 9.0 10.9 13.1 15.5 18.2 YFI19K1E 3.9 4.1 4.3 4.4 4.6 4.8 5.0
Digital Models with Vapor Injection
YFJ10K1E 3.2 4.0 4.9 6.0 7.1 8.5 9.9 YFJ10K1E 2.1 2.2 2.3 2.4 2.5 2.6 2.7
YFJ15K1E 4.7 5.8 7.2 8.7 10.4 12.4 14.5 YFJ15K1E 3.1 3.3 3.4 3.6 3.7 3.8 4.0
YFJ19K1E 5.8 7.3 9.0 10.9 13.1 15.5 18.2 YFJ19K1E 3.9 4.1 4.3 4.4 4.6 4.8 5.0
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary Data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R454A R454A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Models with Liquid injection
YF05K1E 1.4 1.7 2.1 2.6 3.2 3.9 4.7 YF05K1E 1.2 1.3 1.3 1.4 1.5 1.6 1.7
YF06K1E 1.7 2.1 2.7 3.3 4.0 4.8 5.7 YF06K1E 1.4 1.5 1.5 1.6 1.7 1.7 1.8
YF07K1E 1.9 2.3 2.9 3.6 4.3 5.3 6.3 YF07K1E 1.6 1.6 1.7 1.7 1.8 1.9 1.9
YF09K1E 2.3 2.9 3.7 4.5 5.5 6.6 7.9 YF09K1E 1.9 2.0 2.1 2.2 2.3 2.5 2.7
YF10K1E 2.7 3.4 4.3 5.2 6.4 7.7 9.2 YF10K1E 2.2 2.3 2.4 2.5 2.6 2.7 2.8
YF13K1E 3.4 4.2 5.2 6.4 7.8 9.4 11.4 YF13K1E 2.7 2.8 2.9 3.1 3.2 3.3 3.4
YF15K1E 4.0 5.0 6.2 7.6 9.2 11.2 13.4 YF15K1E 3.2 3.3 3.5 3.6 3.8 3.9 4.1
YF19K1E 5.2 6.5 8.1 9.9 12.1 14.6 17.6 YF19K1E 3.9 4.1 4.4 4.6 4.8 5.1 5.3
Models with Vapor Injection
YFI10K1E 3.8 4.8 5.8 7.0 8.4 9.9 11.7 YFI10K1E 2.5 2.6 2.8 2.9 3.0 3.2 3.3
YFI15K1E 5.6 7.0 8.5 10.3 12.3 14.5 17.0 YFI15K1E 3.6 3.8 4.0 4.3 4.4 4.6 4.8
YFI19K1E 7.0 8.7 10.7 12.9 15.4 18.2 21.3 YFI19K1E 4.5 4.8 5.1 5.3 5.6 5.8 6.0
Digital Models with Vapor Injection
YFJ10K1E 3.8 4.8 5.8 7.0 8.4 9.9 11.7 YFJ10K1E 2.5 2.6 2.8 2.9 3.0 3.2 3.3
YFJ15K1E 5.6 7.0 8.5 10.3 12.3 14.5 17.0 YFJ15K1E 3.6 3.8 4.0 4.3 4.4 4.6 4.8
YFJ19K1E 7.0 8.7 10.7 12.9 15.4 18.2 21.3 YFJ19K1E 4.5 4.8 5.1 5.3 5.6 5.8 6.0

Conditions: Suction Gas Return 20°C / Subcooling 0K


Preliminary Data

63 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland ZF and ZFD scroll compressor ranges for low temperature
refrigeration using R407A/F, R448A/R449A and R404A
Copeland developed the ZF range to provide the best performance
in low temperature. The range has a wide application envelope as it
can operate from -40°C evaporating temperature to +7°C. They have
been optimized in their design to perfectly fit frozen food application
requirements. Thanks to their scroll compliance mechanism, these
scroll compressors feature particularly high tolerance to liquid slugging.

The range consists of:


• ZF*K4E models that operate with liquid injection in order to control
discharge temperature and increase the operating envelope.
• ZF*KVE models that are optimized for vapor injection with use of a
sub-cooler. This boosts the refrigeration system cooling capacity
and efficiency.
• ZF*K5E models that operate both with liquid injection or vapor
injection.
ZF compressor for low temperature
These compressors are qualified for R407A/F, R448A/R449A, R404A refrigeration with and without sound shell
and R134a for certain models.

ZFD digital scroll compressors

Based on the unique Copeland compliant scroll design, the digital modulation operates on a simple mechanism. Capacity control is
achieved by separating the scroll sets axially over a small period of time. It is a simple mechanical solution allowing precise temperature
control and system efficiency and it requires no other components.

Digital scroll technology provides continuous, stepless modulation from 10% to 100% with no operating envelope restriction. As a result,
system pressures and temperatures are tightly controlled. These compressors provide optimum performance for refrigeration units,
refrigeration packs, process and agricultural units.

ZF and ZFD compressor line-up

Digital ZFD

ZF with Vapor Injection

ZF with Liquid Injection

Displacement (m3/h)
0 5 10 15 20 25 30 35 40 45 50

Features and benefits Maximum allowable pressure (PS)

• Wide operating envelope with 10°C low condensing • ZF06 to ZF18 (K4E/KVE):
temperature to minimize energy consumption Low Side PS 21 bar(g) / High Side PS 32 bar(g)
• One model for multiple refrigerants • ZF25 to ZF54 (K5E):
• Light weight and compactness, up to half the weight Low Side PS 22.6 bar(g) / High Side PS 32 bar(g)
of equivalent semi-hermetic compressor • Digital ZFD:
• Optional sound shell allowing up to 10 dBA Low Side PS 22.6 bar(g) / High Side PS 32 bar(g)
sound attenuation
• ZF models with liquid injection
- Easy, efficient and reliable injection via
Discharge Temperature Control valve (DTC)
• ZF models with enhanced vapor injection
- Seasonal efficiencies compared to Copeland’s best
semi-hermetic compressors
- Improved system capacity and efficiency by 40% and
25% respectively, making them the most efficient
compressors on the market.
- Possibility to reduce the equipment and component
sizes by using smaller compressors

GPC-EN-2024 REFRIGERATION APPLICATIONS 64


Operating envelope R407A Operating envelope R407F

ZF models - for vapor injection ZF models - for Vapor Injection


70 70
Condensing Temperature °C

60 60

Condensing Temperature °C
50 50

40 40

30 30

20 20

10 10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10

Evaporating Temperature °C Evaporating Temperature °C


20K Suction Superheat 20K Suction Superheat
20K Superheat + Liquid Injection 20K Superheat + Liquid Injection
20°C Suction Gas Return + Liquid Injection 20°C Suction Gas Return + Liquid Injection

ZF models - for liquid injection ZF models - for liquid injection


70
70
Condensing Temperature °C

60
60
Condensing Temperature °C

50
50

40
40

30
30

20
20

10
10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10
Evaporating Temperature °C
Evaporating Temperature °C
20°C Suction Gas Return + Liquid Injection
10K Suction Superheat 20°C Suction Gas Return

ZFD models ZFD models


70 70

60 60
Condensing Temperature °C

Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10
Evaporating Temperature °C Evaporating Temperature °C
20°C Suction Gas Return + Liquid Injection 20°C Suction Gas Return + Liquid Injection

65 GPC-EN-2024 REFRIGERATION APPLICATIONS


Operating envelope R448A/R449A
ZF Models - for liquid injection ZFD digital models
70 70

60 60
Condensing Temperature °C

Condensing Temperature °C
50 50

40 40

30 30

20 20

10 10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10
Evaporating Temperature °C Evaporating Temperature °C

25°C Suction Gas Return + Liquid Injection 20K Suction Superheat


20K Superheat + Liquid Injection
20°C Suction Gas Return + Liquid Injection
For individual model details please refer to Copeland Select Software.

Technical overview

Sound Pressure @1
Discharge (inch)

Maximum Locked
Oil Quantity (l)
Suction (inch)
Displacement

m - db(A)***
Motor
Nominal hp

Operating Cur- Rotor


Rotalock

Rotalock

Net Weight Version/ Code


(m3/h)

Length/Width/ rent (A) Current (A)


Models
Height (mm) (kg)

3 Ph** 3 Ph** 3 Ph**

Models with Liquid Injection only


ZF06K4E 2.0 5.9 1 1/4 1 1.3 243/245/369 25.4 TFD 5 26 57
ZF08K4E 2.5 7.3 1 /4 1
1 1.5 243/245/391 27.2 TFD 6 32 59
ZF09K4E 2.8 8.0 1 1/4 1 1.5 243/244/391 27.0 TFD 6 40 62
ZF11K4E 3.5 9.9 1 /4 1
1 1.5 243/244/405 28.0 TFD 7 46 63
ZF13K4E 4.0 11.8 1 1/4 1 1.9 246/251/442 38.0 TFD 8 51 65
ZF15K4E 5.0 14.5 1 /4 1
1 1.9 246/251/442 39.0 TFD 10 64 65
ZF18K4E 6.0 17.1 1 1/4 1 1.9 246/251/442 41.0 TFD 12 74 67
Models with Vapor Injection only
ZF13KVE 4.0 11.7 1 1/4 1 1.9 246/251/442 38.0 TFD 9 64 63
ZF18KVE 6.0 17.1 1 /4 1
1 1.9 246/251/442 39.5 TFD 13 74 67
Models which can have Liquid or Vapor Injection
ZF25K5E 7.5 21.4 1 1/4 1 1/4 1.9 246/257/452 39.5 TFD 16 102 70
ZF34K5E 10.0 29.1 1 /4 3
1 /4 1
3.4 280/280/534 63.1 TFD 25 100 68
ZF41K5E 13.0 35.3 1 3/4 1 1/4 3.4 280/280/534 63.1 TFD 29 118 69
ZF49K5E 15.0 42.4 1 /4 3
1 /4 1
3.4 280/280/552 66.2 TFD 30 139 72
ZF54K5E 17.0 48.3 1 3/4 1 1/4 3.4 363/312/552 66.2 TFD 31 168 78
Digital Models
ZFD13KVE EVI 4.0 11.7 1 1/4 1 1.9 246/250/481 38 TFD 9 64 65
ZFD18KVE EVI 6.0 17.1 1 /4 1
1 1.9 300/299/481 43 TFD 13 74 67
ZFD25KVE EVI 7.5 21.4 1 1/4 1 1/4 1.9 246/250/481 43 TFD 16 102 70
ZFD41K5E 10.0 35.3 1 /4 3
1 /4 1
3.4 310/280/534 66 TFD 20 118 73
ZFD41K5E EVI 13.0 35.3 1 /4 3
1 /4 1
3.4 310/280/534 66 TFD 20 118 72

** 3 Ph: 380-420V/ 50Hz


*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

GPC-EN-2024 REFRIGERATION APPLICATIONS 66


Capacity data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Models with Liquid Injection Only
ZF06K4E 1.2 1.5 1.9 2.3 2.8 3.5 4.2 ZF06K4E 1.2 1.2 1.2 1.3 1.4 1.4 1.5
ZF08K4E 1.4 1.9 2.4 3.0 3.6 4.4 5.3 ZF08K4E 1.4 1.4 1.5 1.6 1.6 1.7 1.8
ZF09K4E 1.6 2.0 2.6 3.2 3.9 4.8 5.9 ZF09K4E 1.5 1.5 1.6 1.6 1.7 1.8 1.9
ZF11K4E 2.0 2.6 3.2 4.0 4.9 6.0 7.3 ZF11K4E 1.9 1.9 1.9 2.0 2.0 2.2 2.3
ZF13K4E 2.2 2.9 3.6 4.5 5.6 6.8 8.3 ZF13K4E 2.3 2.3 2.4 2.5 2.5 2.6 2.8
ZF15K4E 2.7 3.5 4.4 5.5 6.8 8.4 10.2 ZF15K4E 2.7 2.8 2.9 3.1 3.2 3.4 3.6
ZF18K4E 3.3 4.3 5.4 6.7 8.3 10.2 12.4 ZF18K4E 3.3 3.4 3.5 3.6 3.8 3.9 4.1
Models with Vapor Injection Only
ZF13KVE 3.1 3.9 4.9 5.9 7.2 8.7 10.4 ZF13KVE 2.4 2.4 2.5 2.6 2.7 2.7 2.7
ZF18KVE 4.9 6.0 7.3 8.8 10.8 13.3 16.4 ZF18KVE 3.4 3.5 3.6 3.7 3.9 4.1 4.4
Models which can have Liquid or Vapor Injection
ZF25K5E 4.3 5.5 6.9 8.6 10.7 13.2 16.0 ZF25K5E 4.0 4.2 4.5 4.7 4.9 5.2 5.4
ZF25K5E (EVI) 6.1 7.7 9.4 11.4 13.5 15.8 18.2 ZF25K5E (EVI) 4.3 4.4 4.6 4.8 5.0 5.3 5.5
ZF34K5E 5.9 7.6 9.6 12.1 15.0 18.3 22.3 ZF34K5E 5.1 5.5 5.9 6.2 6.6 6.9 7.3
ZF34K5E (EVI) 8.0 9.9 12.1 14.6 17.4 20.7 24.2 ZF34K5E (EVI) 5.3 5.5 5.7 5.9 6.1 6.3 6.4
ZF41K5E 7.3 9.3 11.7 14.5 17.9 21.8 26.4 ZF41K5E 6.2 6.7 7.1 7.6 8.0 8.4 8.9
ZF41K5E (EVI) 10.1 12.6 15.5 18.7 22.1 25.8 29.7 ZF41K5E (EVI) 6.7 6.9 7.2 7.4 7.6 7.8 8.0
ZF49K5E 8.6 11.2 14.1 17.7 21.9 26.8 32.5 ZF49K5E 7.6 8.2 8.7 9.2 9.7 10.2 10.7
ZF49K5E (EVI) 12.1 15.1 18.4 22.3 26.8 ZF49K5E (EVI) 8.0 8.3 8.5 8.8 9.1
ZF54K5E 9.5 12.2 15.4 19.3 23.8 ZF54K5E 8.1 8.6 9.3 10.0 10.8
ZF54K5E (EVI) 14.5 17.8 21.6 26.1 31.4 ZF54K5E (EVI) 9.7 10.1 10.4 10.7 11.1
Digital Models
ZFD13KVE EVI 3.1 4.1 5.2 6.4 7.7 9.2 10.9 ZFD13KVE EVI 2.7 2.8 2.8 2.9 2.9 3.0 3.1
ZFD18KVE EVI 4.9 6.0 7.3 8.8 10.8 13.3 16.4 ZFD18KVE EVI 3.4 3.5 3.6 3.7 3.9 4.1 4.4
ZFD25KVE EVI 6.1 7.7 9.4 11.4 13.5 15.8 18.2 ZFD25KVE EVI 4.3 4.4 4.6 4.8 5.0 5.3 5.5
ZFD41K5E 7.3 9.3 11.8 14.6 ZFD41K5E 6.2 6.7 7.2 7.5
ZFD41K5E EVI 10.1 12.6 15.5 18.7 22.1 25.8 23.7 ZFD41K5E EVI 6.7 6.9 7.2 7.4 7.6 7.8 8.0
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary Data

67 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R407F R407F
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Models with Liquid Injection Only
ZF06K4E 1.2 1.5 1.9 2.3 2.8 3.5 4.2 ZF06K4E 1.3 1.3 1.3 1.4 1.4 1.5 1.6
ZF08K4E 1.4 1.9 2.4 3.0 3.6 4.4 5.3 ZF08K4E 1.5 1.5 1.6 1.6 1.7 1.8 1.9
ZF09K4E 1.6 2.0 2.6 3.2 3.9 4.8 5.9 ZF09K4E 1.6 1.6 1.6 1.7 1.8 1.9 2.0
ZF11K4E 2.0 2.6 3.2 4.0 4.9 6.0 7.3 ZF11K4E 1.9 2.0 2.0 2.1 2.2 2.3 2.4
ZF13K4E 2.2 2.9 3.6 4.5 5.6 6.8 8.3 ZF13K4E 2.4 2.4 2.5 2.6 2.7 2.8 2.9
ZF15K4E 2.7 3.5 4.4 5.5 6.8 8.4 10.2 ZF15K4E 2.8 3.0 3.1 3.2 3.4 3.5 3.8
ZF18K4E 3.3 4.3 5.4 6.7 8.3 10.2 12.4 ZF18K4E 3.5 3.6 3.7 3.8 4.0 4.1 4.3
Models with Vapor Injection Only
ZF13KVE 3.3 4.3 5.4 6.7 8.1 9.7 11.5 ZF13KVE 2.8 2.9 3.0 3.0 3.1 3.2 3.3
ZF18KVE 4.9 6.1 7.6 9.3 11.3 13.5 16.0 ZF18KVE 3.8 4.0 4.1 4.2 4.4 4.5 4.7
Models which can have Liquid or Vapor Injection
ZF25K5E 4.5 5.8 7.3 9.1 11.3 13.8 16.8 ZF25K5E 4.2 4.4 4.7 4.9 5.2 5.4 5.7
ZF25K5E (EVI) 6.4 8.0 9.9 11.9 14.2 16.6 19.1 ZF25K5E (EVI) 4.5 4.7 4.9 5.1 5.3 5.5 5.8
ZF34K5E 6.2 8.0 10.1 12.7 15.7 19.3 23.4 ZF34K5E 5.6 5.8 6.0 6.2 6.4 6.6 6.8
ZF34K5E (EVI) 8.3 10.4 12.7 15.4 18.4 21.7 25.4 ZF34K5E (EVI) 5.3 5.5 5.7 5.9 6.1 6.3 6.4
ZF41K5E 7.6 9.7 12.3 15.2 18.8 22.9 27.7 ZF41K5E 6.5 7.0 7.5 8.0 8.4 8.9 9.3
ZF41K5E (EVI) 10.6 13.3 16.3 19.6 23.2 27.1 31.2 ZF41K5E (EVI) 7.0 7.3 7.5 7.7 8.0 8.2 8.4
ZF49K5E 9.1 11.7 14.8 18.6 23.0 28.1 34.2 ZF49K5E 8.0 8.6 9.1 9.6 10.2 10.7 11.2
ZF49K5E (EVI) 14.1 17.1 20.5 24.5 28.9 ZF49K5E (EVI) 9.1 9.7 10.3 10.8 11.3
ZF54K5E 9.9 12.6 15.8 19.5 23.9 ZF54K5E 8.5 9.1 9.8 10.5 11.3
ZF54K5E (EVI) 15.2 18.7 22.7 27.4 33.0 ZF54K5E (EVI) 10.2 10.6 10.9 11.3 11.6
Digital Modelsc
ZFD13KVE EVI 3.3 4.3 5.4 6.7 8.1 9.7 11.4 ZFD13KVE EVI 2.8 2.9 3.0 3.0 3.1 3.1 3.2
ZFD18KVE EVI 4.9 6.1 7.6 9.3 11.3 13.5 16.0 ZFD18KVE EVI 3.8 4.0 4.1 4.2 4.4 4.5 4.7
ZFD25KVE EVI 6.4 8.0 9.9 11.9 14.2 16.6 19.1 ZFD25KVE EVI 4.5 4.7 4.9 5.1 5.3 5.5 5.8
ZFD41K5E 7.3 9.3 11.8 14.6 ZFD41K5E 6.2 6.7 7.2 7.5
ZFD41K5E EVI 23.5 29.8 37.2 45.9 ZFD41K5E KVE 6.4 6.6 6.8 7.1
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 68


Capacity data

Condensing Temperature 40°C

R448A/ Cooling Capacity (kW) R448A/ Power Input (kW)


R449A Evaporating Temperature (°C) R449A Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Models with Liquid Injection Only
ZF06K4E 1.2 1.5 1.9 2.4 2.9 3.6 4.3 ZF06K4E 1.3 1.4 1.4 1.4 1.5 1.5 1.6
ZF08K4E 1.4 1.8 2.3 2.9 3.5 4.4 5.3 ZF08K4E 1.4 1.5 1.6 1.6 1.7 1.8 1.9
ZF09K4E 1.7 2.1 2.6 3.3 4.0 4.9 5.9 ZF09K4E 1.5 1.5 1.6 1.7 1.8 1.9 2.0
ZF11K4E 2.1 2.6 3.3 4.0 4.9 6.0 7.2 ZF11K4E 2.0 2.0 2.1 2.2 2.3 2.4 2.6
ZF13K4E 2.4 3.1 3.9 4.8 5.9 7.2 8.6 ZF13K4E 2.1 2.2 2.3 2.4 2.5 2.6 2.8
ZF15K4E 3.0 3.8 4.8 5.9 7.2 8.6 10.3 ZF15K4E 2.8 2.8 3.0 3.1 3.3 3.4 3.6
ZF18K4E 3.6 4.7 5.9 7.2 8.8 10.7 12.9 ZF18K4E 3.6 3.6 3.6 3.6 3.7 3.9 4.0
Models with Vapor Injection Only
ZF13KVE 3.2 4.1 5.1 6.2 7.5 9.0 10.6 ZF13KVE 2.5 2.6 2.7 2.8 2.8 2.9 2.9
ZF18KVE 4.9 6.0 7.4 9.0 10.9 13.0 15.5 ZF18KVE 3.4 3.7 3.9 4.0 4.1 4.2 4.3
Models which can have Liquid or Vapor Injection
ZF25K5E 4.9 6.1 7.6 9.4 11.4 13.8 16.6 ZF25K5E 3.8 3.9 4.1 4.3 4.5 4.8 5.0
ZF25K5E (EVI) 6.1 7.7 9.4 11.3 13.4 15.6 17.9 ZF25K5E (EVI) 4.0 4.3 4.6 4.9 5.2 5.4 5.6
ZF34K5E 6.1 7.8 9.8 12.1 14.9 18.1 21.7 ZF34K5E 5.1 5.3 5.4 5.7 6.0 6.3 6.7
ZF34K5E (EVI) 8.1 10.3 12.7 15.5 18.6 22.1 26.0 ZF34K5E (EVI) 5.7 6.1 6.5 7.0 7.5 8.1 8.7
ZF41K5E 7.4 9.4 11.8 14.6 17.8 21.5 25.8 ZF41K5E 5.8 6.1 6.5 7.0 7.7 8.4 9.4
ZF41K5E (EVI) 9.8 12.5 15.5 18.9 22.6 26.9 31.6 ZF41K5E (EVI) 7.0 7.5 8.0 8.6 9.2 9.9 10.7
ZF49K5E 9.1 11.6 14.6 18.1 22.2 27.0 32.5 ZF49K5E 7.7 7.8 8.0 8.4 8.9 9.4 10.0
ZF49K5E (EVI) 11.8 14.8 18.2 22.1 26.6 ZF49K5E (EVI) 8.6 9.1 9.6 10.2 10.9
ZF54K5E 10.0 12.7 15.9 19.8 24.3 ZF54K5E 8.0 8.6 9.3 10.1 10.9
ZF54K5E (EVI) 14.1 17.4 21.4 25.9 31.2 ZF54K5E (EVI) 10.5 11.1 11.7 12.4 13.3
Digital Models
ZFD13KVE EVI 4.0 4.9 6.0 7.2 8.5 10.0 11.7 ZFD13KVE EVI 2.9 3.0 3.1 3.2 3.3 3.4 3.5
ZFD18KVE EVI 6.1 7.3 8.7 10.4 12.3 14.4 16.9 ZFD18KVE EVI 4.0 4.3 4.5 4.6 4.8 5.0 5.1
ZFD25KVE EVI 7.7 9.3 11.2 13.2 15.3 17.5 19.7 ZFD25KVE EVI 4.8 5.1 5.4 5.7 6.0 6.3 6.6
ZFD41K5E EVI 12.5 15.0 18.1 21.5 25.4 29.5 33.9 ZFD41K5E EVI 7.9 8.4 8.8 9.3 9.7 10.1 10.6
ZFD41K5E 8.6 10.6 13.0 15.7 18.9 22.6 27.0 ZFD41K5E 6.3 6.7 7.1 7.5 7.9 8.4 8.8
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary Data

69 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland ZS, ZB & ZF*KA small scroll compressor range
for medium and low temperature applications

As an extension to the existing ZB*KCE and ZF*K4E scroll range,


Copeland ZS*KA, ZB*KA and ZF*KA scroll compressors represent the
latest innovation in scroll technology for refrigeration equipment covering
a small size displacement range of 2.4 m3/h to 6.7 m3/h.

ZS*KA and ZB*KA models are intended for medium temperature


refrigeration type systems, and are ideally suited for applications such as
walk-in coolers, reach-in coolers, cold rooms, display cases and milk tank
units. The ZB*KA scrolls cover a range from 0.7hp to 1.3hp, while ZS*KA
cover 1.3hp to 1.8hp.

ZF*KA models are suitable for low temperature type systems such as walk-
in freezers and reach-in freezers. They cover a range from 1hp to 2.5hp.

ZS, ZB and ZF*KA are multi-refrigerant capable and feature low sound and
low vibration, which is particularly important in the retail and food service
sector and recommended for supermarkets, restaurants, convenience Copeland ZS*KA scroll compressor range for
stores and milk cooling operations. Their compact design provides medium temperature refrigeration applications
seasonal efficiencies up to 28% higher than the equivalent hermetic
reciprocating compressors. They are qualified for today’s HFC as well as
new low GWP refrigerants and HFO blends.

Compressor line-up

ZS*KA
ZB*KA
ZF*KA

Displacement (m3/h)
0 2 4 6 8

Features and benefits Maximum allowable pressure (PS)

• Copeland scroll axial and radial compliance for superior


• ZS09 to ZS13KA:
reliability and efficiency
Low Side PS 21.6 bar(g) / High Side PS 31.9 bar(g)
• High seasonal efficiencies as scrolls are designed at the
condition where equipment runs most of the time • ZB06 to ZB08KA:
• Up to 15% efficiency advantage over hermetic Low Side PS 21.0 bar(g) / High Side PS 28.8 bar(g)
reciprocating compressors at rating conditions, and up to • ZF03 to ZF07KA:
28% improvement at lower condensing temperatures Low Side PS 21.0 bar(g) / High Side PS 28.8 bar(g)
• Availability of optional sound shell on all models providing
up to 10 dBA additional sound attenuation for silent
operation
• Wide operating ranges: from -25°C to 10°C covering a
minimum condensing limit of 10°C for ZS*KA and ZB*KA
and -40°C to -12°C for ZF*KA
• Qualified for R407A/F/C, R448A, R449A, R404A and
R134a refrigerants

GPC-EN-2024 REFRIGERATION APPLICATIONS 70


Operating envelope

ZS*KA - R134a ZB*KA - R134a


80 70

70
75
Condensing Temperature °C

Condensing Temperature °C
60
65

50
55
40
45
30

35
20

10 25

0 15
-25 -20 -15 -10 -5 0 5 10 -15 -10 -5 0 5 10 15 20
Evaporating Temperature °C Evaporating Temperature °C
20°C Suction Gas Return 20°C Suction Gas Return

ZS*KA - R448A/R449A ZB*KA - R448A/R449A


70 70

60 60
Condensing Temperature °C

Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-30 -25 -20 -15 -10 -5 0 5 10 15 -25 -20 -15 -10 -5 0 5 10
Evaporating Temperature °C Evaporating Temperature °C
10K Suction Superheat 20°C Suction Gas Return 10K Suction Superheat 20°C Suction Gas Return

ZF*KA - R448A/R449A
70

60
Condensing Temperature °C

50

40

30

20

10

0
-45 -40 -35 -30 -25 -20 -15 -10

Evaporating Temperature °C
20°C Suction Gas Return

71 GPC-EN-2024 REFRIGERATION APPLICATIONS


Technical overview

Rotalock Suction
Maximum

@1 m - dB(A)***
Discharge (inch)

Net Weight (kg)

Sound Pressure
Oil Quantity (l)
Motor Locked Rotor

Displacement
Operating

Nominal hp
Version/ Code Current (A)

Rotalock
Current (A)

(m3/h)

(inch)
Length/Width/
Models
Height (mm)
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**

Medium Temperature
ZB06KAE 0.8 2.4 3/4 1/2 0.7 246/246/380 21 PFJ TFD 5 2 32 15 59
ZB07KAE 1.0 2.9 3/4 1/2 0.7 246/246/380 23 PFJ TFD 6 2 45 20 59
ZB08KAE 1.2 3.4 3/4 1/2 0.7 246/246/380 23 PFJ TFD 7 2 45 20 59
ZS09KAE 1.3 3.7 3/4 1/2 0.7 246/246/399 22 PFJ TFD 7 3 45 27 58
ZS11KAE 1.5 4.4 3/4 1/2 0.7 246/246/399 22 PFJ TFD 9 3 45 27 58
ZS13KAE 1.8 5.0 3/4 1/2 0.7 246/246/399 22 PFJ TFD 10 4 54 29 59
Low Temperature
ZF03KAE 1.0 2.8 3/4 1/2 0.7 246/246/387 22 PFJ TFD 5 2 40 20 40
ZF04KAE 1.3 3.7 3/4 1/2 0.7 246/246/387 22 PFJ TFD 6 3 45 27 45
ZF05KAE 1.5 4.4 3/4 1/2 0.7 246/246/387 22 PFJ TFD 7 5 45 27 45
ZF07KAE 2.5 6.7 3/4 1/2 0.7 246/246/387 23 PFJ TFD 11 4 79 27 79
* 1Ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data
Condensing Temperature 40°C
Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Medium Temperature
ZB06KAE 0.9 1.1 1.4 1.7 ZB06KAE 0.6 0.6 0.6 0.6
ZB07KAE 1.0 1.3 1.7 2.1 ZB07KAE 0.7 0.7 0.7 0.8
ZB08KAE 1.2 1.5 1.9 2.3 ZB08KAE 0.8 0.8 0.9 0.9
ZS09KAE 0.9 1.2 1.5 1.8 2.2 2.6 ZS09KAE 0.7 0.8 0.8 0.8 0.8 0.9
ZS11KAE 1.1 1.4 1.7 2.1 2.6 3.1 ZS11KAE 0.9 0.9 1.0 1.0 1.0 1.1
ZS13KAE 1.2 1.6 2.0 2.4 2.9 3.6 ZS13KAE 1.0 1.1 1.1 1.2 1.2 1.2
Low Temperature
ZF03KAE 0.5* 0.6* 0.8* 0.9* 1.2* ZF03KAE 0.6* 0.6* 0.7* 0.7* 0.7*
ZF04KAE 0.6* 0.8* 1.1* 1.4* 1.7* ZF04KAE 0.7* 0.8* 0.8* 0.9* 0.9*
ZF05KAE 0.8* 1.0* 1.3* 1.6* 2.0* ZF05KAE 0.9* 1.0* 1.0* 1.0* 1.0*
ZF07KAE 1.3* 1.6* 2.0* 2.5* 3.1* ZF07KAE 1.3* 1.4* 1.4* 1.5* 1.6*
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R407F R407F
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Medium Temperature
ZB06KAE 0.9 1.1 1.4 1.7 ZB06KAE 0.6 0.6 0.6 0.6
ZB07KAE 1.0 1.3 1.7 2.1 ZB07KAE 0.7 0.7 0.7 0.8
ZB08KAE 1.2 1.5 1.9 2.3 ZB08KAE 0.8 0.8 0.9 0.9
ZS09KAE 1.2* 1.5 1.9 2.3 2.7 ZS09KAE 0.8* 0.8 0.9 0.9 0.9
ZS11KAE 1.4* 1.8 2.2 2.7 3.3 ZS11KAE 1.0* 1.0 1.1 1.1 1.1
ZS13KAE 1.6* 2.1 2.6 3.1 3.7 ZS13KAE 1.1* 1.2 1.2 1.2 1.3
Low Temperature
ZF03KAE 0.5* 0.6* 0.8* 1.0* 1.2* ZF03KAE 0.6* 0.6* 0.7* 0.7* 0.8*
ZF04KAE 0.6* 0.8* 1.1* 1.4* 1.7* ZF04KAE 0.7* 0.8* 0.8* 0.9* 1.0*
ZF05KAE 0.8* 1.0* 1.3* 1.6* 2.0* ZF05KAE 0.9* 1.0* 1.0* 1.0* 1.0*
ZF07KAE 1.3* 1.6* 2.0* 2.5* 3.1* ZF07KAE 1.3* 1.4* 1.4* 1.5* 1.6*
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K

GPC-EN-2024 REFRIGERATION APPLICATIONS 72


Capacity data
Condensing Temperature 40°C

R448A/ Cooling Capacity (kW) R448A/ Power Input (kW)


R449A Evaporating Temperature (°C) R449A Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Medium Temperature
ZB06KAE 0.9 1.2 1.4 1.7 ZB06KAE 0.6 0.6 0.6 0.6
ZB07KAE 1.1 1.4 1.7 2.1 ZB07KAE 0.7 0.7 0.8 0.8
ZB08KAE 1.2 1.5 1.9 2.3 ZB08KAE 0.8 0.9 0.9 0.9
ZS09KAE 0.9 1.1 1.4 1.7 2.1 2.5 ZS09KAE 0.7 0.8 0.8 0.9 0.9 0.9
ZS11KAE 1.0 1.3 1.6 2.0 2.5 3.1 ZS11KAE 0.8 0.9 1.0 1.0 1.0 1.0
ZS13KAE 1.4 1.8 2.3 2.8 3.4 4.1 ZS13KAE 1.1 1.3 1.4 1.4 1.5 1.5
Low Temperature
ZF03KAE 0.5* 0.7* 0.8* 1.0* 1.3* ZF03KAE 0.7* 0.7* 0.7* 0.7* 0.7*
ZF04KAE 0.7* 0.9* 1.1* 1.4* 1.8* ZF04KAE 0.7* 0.8* 0.8* 0.9* 1.0*
ZF05KAE 0.8* 1.1* 1.3* 1.7* 2.1* ZF05KAE 1.0* 1.0* 1.0* 1.0* 1.0*
ZF07KAE 1.3* 1.7* 2.1* 2.6* 3.2* ZF07KAE 1.3* 1.4* 1.4* 1.5* 1.6*
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -35 -30 -25 -20 -15 -10 -5 Model -35 -30 -25 -20 -15 -10 -5
Medium Temperature
ZB06KAE 0.7 0.9 1.1 ZB06KAE 0.4 0.4 0.4
ZB07KAE 0.8 1.0 1.3 ZB07KAE 0.5 0.5 0.5
ZB08KAE 0.9 1.2 1.5 ZB08KAE 0.5 0.6 0.6
ZS09KAE 0.9 1.1 1.4 1.7 ZS09KAE 0.5 0.6 0.6 0.6
ZS11KAE 1.1 1.3 1.7 2.0 ZS11KAE 0.6 0.7 0.7 0.7
ZS13KAE 1.2 1.5 1.9 2.3 ZS13KAE 0.7 0.8 0.8 0.8
Conditions: Suction Gas Return 20°C / Subcooling 0K

73 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland ZO & ZOD scroll compressor ranges for
R744-subcritical refrigeration
Copeland ZO scroll compressors have been designed for use
in R744 (CO2) low temperature refrigeration systems. These
compressors are suitable for usage in CO2-subcritical cascade and
booster systems.

Increasing environmental concerns about potential direct emissions


from HFC-based refrigeration systems into the
atmosphere have led to the revival of R744 in the European
refrigeration market. Regionally, this trend is reinforced by legislation
and taxation schemes which favor the usage of refrigerant R744.

In comparison with HFC refrigerants, the specific properties of R744


require changes in the design of the refrigeration system. The range
of Copeland ZO scroll compressors has been
particularly designed to exploit the characteristics of the R744
refrigeration system. Efficiency, reliability and liquid handling
advantages of the Copeland scroll technology equally apply.

The optimized design of ZO compressors effectively address the


challenges of R744 systems, i.e. high pressure levels, higher mass
flow for a given displacement while securing proper lubrication.
ZO compressor for low temperature refrigeration
The range consists of 6 models including 2 digital models for 10 to
100% continuous cooling capacity modulation.

ZO and ZOD compressor line-up

Digital ZOD

ZO

Cooling Capacity (kW)


0 2 4 6 8 10 12 14 16 18 20 22 24

Conditions EN12900 R744: Evaporating -35°C, Refrigeration -5°C ,Suction Superheat 10K, Subcooling 0K

Features and benefits Operating envelope R744


10
• Optimized for high efficiency in CO2-subcritical cascade
and booster systems
5
• High condensing temperature limit allowing for optimized
Condensing Temperature °C

overall system design


0
• Compact design minimizing required machine room space
• Half the weight of equivalent semi-hermetic compressors
-5
• Optional sound shell allowing 10 dBA sound attenuation
• High bearing reliability and lubrication of all critical parts
-10
under all conditions including liquid slugging
• Availability of a digital model offering simple, stepless 10
to 100% capacity modulation -15

-20
Maximum allowable pressure (PS)
-25
• ZO: -55 -50 -45 -40 -35 -30 -25 -20
Low Side PS 30 bar(g) / High Side PS 52 bar(g) Evaporating Temperature °C
• Digital ZOD: 0°C Suction Gas Return 20K Superheat
Low Side PS 30 bar(g) / High Side PS 45 bar(g)

For individual model details please refer to Copeland Select Software.

GPC-EN-2024 REFRIGERATION APPLICATIONS 74


Technical overview

@1 m - dB(A)***
Sound Pressure
Stub Discharge
Displacement
Maximum

Width/height
Stub Suction

Oil Quantity

Net Weight
Motor Version/ Locked Rotor
Nominal
Operating Current

Length/
(m3/h)

(inch)

(inch)
Code Current (A)

(mm)

(kg)
(A)
hp
Models

(l)
3 Ph** 3 Ph** 3 Ph**

ZO21K5E 1.5 2.6 1 1/4 1 1.0 228/228/388 22 TFD 3.6 27 52


ZO34K3E 2.0 4.1 1 /4
1
1 1.4 242/242/381 30 TFD 5.5 26 54
ZO45K3E 2.5 5.4 1 1/4 1 1.4 242/242/403 31 TFD 6.2 35 56
ZO58K3E 3.5 6.9 1 /4
1
1 1.4 242/242/417 32 TFD 8.0 48 56
ZO88KCE 5.0 10.1 1 1/4 1 1.9 245/249/440 40 TFD 11.8 64 60
ZO104KCE 6.0 11.7 1 1/4 1 1.9 242/242/461 40 TFD 15.0 74 61
Digital Models
ZOD34K3E 2.0 4.07 1 1/4 1 1.4 242/242/377 30 TFD 5.5 26 55
ZOD104KCE 6.0 11.7 1 /4
1
1 1.9 241/246/484 41 TFD 15.0 75 67
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data

Condensing Temperature: -10°C


Cooling Capacity (kW) Power Input (kW)
R744 R744
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -40 -35 -30 Model -45 -40 -35 -30
ZO21K5E 3.2 4.1 5.1 6.2 ZO21K5E 1.2 1.2 1.2 1.1
ZO34K3E 4.8 6.2 7.8 9.7 ZO34K3E 1.8 1.8 1.8 1.7
ZO45K3E 7.0 8.8 10.9 13.3 ZO45K3E 2.3 2.3 2.3 2.2
ZO58K3E 8.9 11.2 13.9 17.0 ZO58K3E 3.0 3.0 2.9 2.8
ZO88KCE 13.3 17.0 21.0 25.4 ZO88KCE 4.5 4.5 4.4 4.2
ZO104KCE 15.9 19.7 24.1 29.2 ZO104KCE 4.9 5.0 5.1 5.2
Digital Models
ZOD34K3E 5.1 6.4 7.9 9.7 ZOD34K3E 1.8 1.8 1.8 1.7
ZOD104KCE 15.6 19.1 23.2 27.9 ZOD104KCE 5.0 5.0 5.1 5.3
Conditions: 10 K Superheat

75 GPC-EN-2024 REFRIGERATION APPLICATIONS


Sound shell for Copeland scroll compressors quiet operation in
sound critical environment
Environmental noise has become a serious problem that It completely encapsulates the compressor, minimizing sound
can lead to potential contentious situations. It is particularly leaks while cooling performance remains uncompromised.
true for refrigeration applications where kitchen equipment
or compressor packs are often source of disturbing noise in Groundbreaking design techniques and materials, derived from
domestic areas. Copeland put sound minimisation at the centre the automotive industry, were utilized to design the sound shell.
of any of its new compressor development along reliability, The use of low pressure reaction injection moulded parts (top
seasonal efficiency, size and weight reduction. cap cover, terminal box cover and compressor base plate) allows
a 10–12 dBA sound attenuation.
A large portion of equipment acoustic emissions come from
condensers and compressors and in some critical sound It is a significant improvement over conventional sound jackets
sensitive applications the refrigeration installations need to be available from other suppliers that reduce sound by 3–6 dBA
acoustically insulated. Simple solutions are now available to depending on the application. Particular attention was also paid
contain sound emissions. Copeland has developed a dedicated in the design stage to ensure ease of mounting in retrofit, service
sound shell for all Copeland scroll compressors from 2–15 hp. and new installation situations.

Sound shell for Copeland scroll

4 to 6 hp scroll 4 to 6 hp Summit series Summit series


1.3 to 2 hp scroll 2 to 4 hp scroll 4 to 6 hp scroll
ZF with DTC digital scroll 7 to 15 hp scroll digital scroll

Technical overview

Small Scroll Summit Scroll Summit Digital Scroll

All Sizes Small Size Medium Size Large Size Small Size Medium Size

Sound attenuation 10 - 12 dBA

Total weight (kg) 3.4 4.8 4.9 5.1 5.3 5.6

Mantle thickness 25mm

Flammability Conforms to IEC 60335-1 §30

Material

Green felt layer (cotton + binder 1.2 kg/m2)

Mantle Heavy layer (PVC 4.5 kg/m2)

Closure by use of Velcro fastening - High frequency welded on PVC layer

Base plate PU SRIM - Low pressure reaction injection moulding technology

PU SRIM - Low pressure reaction injection moulding technology

Top cap cover Inside insulation green felt and aluminium film

High temperature insulation ring

Terminal box cover PU SRIM - Low pressure reaction injection moulding technology

GPC-EN-2024 REFRIGERATION APPLICATIONS 76


77 GPC-EN-2024 REFRIGERATION APPLICATIONS
Semi-hermetic reciprocating
compressors

Copeland offers different ranges of semi-hermetic reciprocating The Copeland line-up of 4 cylinder compressors for CO2-
compressors with distinct levels of performance and technical transcritical applications is the ideal solution for R744 medium
characteristics depending on the application requirements. temperature cascade and booster systems. It is characterised by
a design pressure of 135 bar. Refrigerant flow and heat transfer
The Stream series have been optimized for best performance. In combination with
the CO2 -subcritical scroll for the low temperature refrigeration
Copeland has introduced Stream, a line of semi-hermetic 4 side, Copeland offers the most energy efficient package
and 6 cylinder compressors. The series provides best in class available on the market today.
performance for today’s HFC-based and uprising natural and low
GWP refrigerants, significantly reducing cost of operation and With advanced protection and diagnostics features for system
environmental impact compared to competing products. reliabilty, reduced service costs and increased equipment
uptime, the Stream series is built to last in today’s modern and
The range consists of 4 and 6 cylinder models, available with changing world.
both inverter and continuous capacity modulation options.

Stream 4 cylinder Stream 6 cylinder Stream 4 cylinder for R744

Stream digital 4 cylinder Stream digital 6 cylinder

GPC-EN-2024 REFRIGERATION APPLICATIONS 78


The S-series The Discus range

Its design is based on traditional “reed” valve plates similar to It is broadly recognized as the most efficient compressor
what is used in reciprocating compressors offered by other whatever the running condition. This range is mainly used in
manufacturers. The performance of such compressors meets medium and low temperature refrigeration applications where
basic market requirements but cannot compete with Discus system efficiency is a priority for the end-user. The key difference
compressors in terms of efficiency. The S-Series ranges from 1.5 between Discus and other reciprocating compressors lies in
to 70 hp and is composed of K and L presented in this catalogue. its valve plate design. Traditional “reed” valves are replaced by
‘puck” type valves that are integrated in the valve plate. This
special design eliminates the dead volume at the end of the
compression and allows for the highest compressor efficiency.
To date, no other reciprocating compressor is able to match
Discus in terms of performance. Available from 4 to 60 hp, they
are referred to as 2D, 3D and 8D in this catalogue.

S-series

Discus 2 cylinder

79 GPC-EN-2024 REFRIGERATION APPLICATIONS


K and L reciprocating compressor range

Small 2-cylinder semi-hermetic reciprocating compressors for


medium and low temperature refrigeration applications and
transport refrigeration.

Designed on the principle of standard reed valve type


technology, these compressors feature an internal oil pump
that guarantees optimum reliability in all operating conditions.

The K-series ranges from 0.5 to 2 hp and the L-series from 2 to


5 hp with a displacement of 4 to 22.5 m3/h.

These compressors are qualified for R407A/F/C, R448A/


R449A, R404A and R134a.

K-Series compressor

K & L compressor line-up

L-Series

K-Series

Displacement (m3/h)
0 2 4 6 8 10 12 14 16 18 20 22 24

Features and benefits Maximum allowable pressure (PS)

• Large operating envelope from 5°C to -45°C evaporating • Low Side PS 22.5 bar (g)/ High Side PS 28 bar (g)
and up to 55°C condensing
• Two motor sizes per displacement, optimized for
different applications
• Compact and light compressors
• Ideal for refrigeration unit or transport applications
• Integrated oil pump for maximum reliability

Operating envelope R404A Operating envelope R134a


70 80

60 70
Condensing Temperature °C
Condensing Temperature °C

50 60

40 50

30 40

20 30

10 20

0 10
-60 -55 -50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20

Evaporating Temperature °C Evaporating temperature °C


Small Motor Large Motor 20°C Suction Gas Return

For individual model details please refer to Copeland Select Software.

GPC-EN-2024 REFRIGERATION APPLICATIONS 80


Operating envelope R448A/R449A
60

50
Condensing Temperature °C

40

30

20

10

0
-40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15
Evaporating Temperature °C

Small Motor 0°C Suction Gas Return + Fan


Large Motor 20°C Suction Gas Return + Fan
Small Motor 20°C Suction Gas Return + Fan

Technical overview

Sound Pressure
Displacement

@1 m - dB(A)
Oil quantity

Net Weight

Motor Version/ Maximum Operating Locked Rotor


Nominal

Length/Width/
(m3/h)

Code Current (A) Current (A)


(kg)

***
hp

Models Height
(l)

(mm)
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**

KM-5 0.5 4.0 0.7 365/235/280 39 CAG EWL 4.8 1.8 24.0 12.2 45
KM-7 0.8 4.0 0.7 365/235/280 39 CAG EWL 6.0 2.4 34.5 12.2 45
KJ-7 0.8 5.1 0.7 365/235/280 39 CAG EWL 5.8 2.3 34.5 12.2 45
KJ-10 1.0 5.1 0.7 365/235/280 39 CAG EWL 7.1 3.2 32.4 15.5 45
KSJ-10 1.0 6.3 0.7 365/235/280 40 CAG EWL 6.7 2.7 32.4 15.5 50
KSJ-15 1.5 6.3 0.7 365/235/280 40 CAG EWL 9.0 3.4 43.0 19.1 53
KL-15 1.5 7.4 0.7 365/235/280 39 CAG EWL 8.4 3.4 43.0 19.1 47
KL-20 2.0 7.4 0.7 365/235/280 39 EWL 3.8 20.4
KSL-20 2.0 9.1 0.7 365/235/280 40 EWL 4.7 20.4
LE-20 2.0 9.9 2.0 470/330/385 78 EWL 5.7 37.6 51
LF-20 2.0 12.9 2.0 470/330/385 80 EWL 5.5 37.6 51
LF-30 3.0 12.9 2.0 470/330/385 80 EWL 7.2 53.0 51
LJ-20 2.0 14.5 2.0 470/330/385 78 EWL 5.6 37.6 52
LJ-30 3.0 14.5 2.0 470/330/385 83 EWL 8.1 53.0 52
LL-30 3.0 18.2 2.0 470/330/385 85 EWL 7.3 50.6 52
LL-40 4.0 18.2 2.0 470/330/385 87 EWL 9.5 58.9 63
LSG-40 4.0 22.5 2.0 470/330/385 77 EWL 8.9 58.9 63
* 1 Ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

81 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R404A R404A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
KM-5 0.2° 0.6° 0.8° 1.3° KM-5 0.3° 0.5° 0.6° 0.7°
KM-7 0.2° 0.5° 0.8° 1.3° 2.0° 2.5° 3.6° KM-7 0.3° 0.5° 0.6° 0.8° 0.9° 1.0° 1.0°
KJ-7 0.4° 0.8° 1.1° 1.8° KJ-7 0.5° 0.7° 0.8° 1.0°
KJ-10 0.3° 0.8° 1.0° 1.8° 2.8° 3.4° 4.9° KJ-10 0.4° 0.7° 0.8° 1.0° 1.2° 1.3° 1.4°
KSJ-10 0.5° 1.0° 1.4° 2.3° KSJ-10 0.7° 0.9° 1.1° 1.3°
KSJ-15 0.5° 1.0° 1.4° 2.3° 3.5° 4.2° 6.1° KSJ-15 0.6° 0.9° 1.0° 1.3° 1.6° 1.7° 1.8°
KL-15 0.6° 1.2° 1.6° 2.6° KL-15 0.8° 1.0° 1.2° 1.5°
KL-20 0.5° 1.1° 1.5° 2.6° 4.1° 5.0° KL-20 0.6° 0.9° 1.1° 1.4° 1.7° 1.8°
KSL-20 0.8° 1.5° 2.0° 3.3° 5.1° 6.1° KSL-20 0.8° 1.2° 1.4° 1.9° 2.3° 2.5°
LE-20 1.1° 1.7° 3.2° 5.1° 6.4° 9.4° LE-20 1.0° 1.2° 1.6° 2.0° 2.2° 2.5°
LF-20 1.8° 2.3° 4.0° LF-20 1.4° 1.7° 2.2°
LF-30 0.7° 1.9° 2.6° 4.6° 7.2° 8.8° 12.8° LF-30 1.0° 1.6° 1.9° 2.4° 2.9° 3.1° 3.4°
LJ-20 1.9° 2.8° 5.0° LJ-20 1.6° 1.9° 2.6°
LJ-30 0.8° 2.1° 2.9° 5.1° 8.0° 9.8° 14.2° LJ-30 1.1° 1.8° 2.1° 2.8° 3.3° 3.6° 3.9°
LL-30 0.9° 2.6° 3.7° 6.5° LL-30 1.1° 2.0° 2.4° 3.3°
LL-40 1.1° 2.7° 3.7° 6.4° 10.2° 12.6° 18.4° LL-40 1.4° 2.2° 2.6° 3.3° 4.0° 4.3° 4.9°
LSG-40 1.4° 3.5° 4.8° 8.2° LSG-40 1.6° 2.6° 3.1° 4.1°
Conditions: Suction Gas Return 20°C / Subcooling 0K
° High discharge temperature - additional cooling required

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
KM-5 0.7° 1.2° 1.5° 2.3° KM-5 0.5° 0.6° 0.6° 0.7°
KJ-7 0.9° 1.6° 2.0° 3.0° KJ-7 0.6° 0.7° 0.8° 0.8°
KSJ-10 1.2° 2.0° 2.5° 3.8° KSJ-10 0.7° 0.8° 0.9° 1.0°
KL-15 1.4° 2.2° 2.8° 4.3° KL-15 0.8° 1.0° 1.1° 1.3°
KSL-15 1.7° 2.8° 3.5° 5.3° KSL-15 1.0° 1.3° 1.4° 1.6°
KSL-20 1.7° 2.9° 3.7° 5.6° KSL-20 1.0° 1.2° 1.4° 1.6°
LE-20 1.5° 2.8° 3.6° 5.6° LE-20 1.0° 1.3° 1.4° 1.5°
LF-20 2.2° 3.8° 4.9° 7.5° LF-20 1.2° 1.6° 1.7° 1.9°
LJ-20 2.6° 4.3° 5.4° 8.3° LJ-20 1.6° 1.9° 2.1° 2.4°
LL-30 3.2° 5.5° 7.0° 10.9° LL-30 1.9° 2.4° 2.6° 3.0°
LSG-40 4.3° 7.2° 9.0° 13.7° LSG-40 2.3° 2.9° 3.2° 3.7°
Conditions: Suction Gas Return 20°C / Subcooling 0K
° High discharge temperature - additional cooling required
For more details about other refrigerants please refer to Copeland Select software.

GPC-EN-2024 REFRIGERATION APPLICATIONS 82


Capacity data
Condensing Temperature 40°C
Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -30 -20 -10 -5 +5 +10 +15 Model -30 -20 -10 -5 +5 +10 +15
KM-5 0.5° 1.1° 1.8° 2.3° KM-5 0.5° 0.7° 0.8° 0.9°
KM-7 1.0° 1.7° 2.2° 3.5° 4.2° KM-7 0.7° 0.8° 0.9° 1.0° 1.0°
KJ-7 0.8° 1.5° 2.4° 3.0° KJ-7 0.7° 0.9° 1.1° 1.2°
KJ-10 1.5° 2.5° 3.2° 4.8° 5.8° KJ-10 0.9° 1.1° 1.2° 1.4° 1.4°
KSJ-10 1.1° 1.9° 3.1° 3.8° KSJ-10 0.9° 1.1° 1.4° 1.5°
KSJ-15 1.9° 3.2° 4.0° 6.0° 7.2° KSJ-15 1.2° 1.5° 1.6° 1.8° 1.8°
KL-15 1.2° 2.2° 3.6° 4.5° KL-15 0.9° 1.2° 1.6° 1.7°
KL-20 2.5° 3.9° 4.8° 7.0° 8.4° KL-20 1.3° 1.6° 1.7° 1.9° 2.0°
KSL-20 2.9° 4.5° 5.6° 8.3° 10.1° KSL-20 1.6° 1.9° 2.1° 2.4° 2.4°
LE-20 1.5° 2.8° 4.8° 6.0° 9.0° 10.9° LE-20 1.2° 1.6° 2.1° 2.3° 2.6° 2.7°
LF-20 2.1° 3.9° 6.4° 8.0° LF-20 1.6° 2.2° 2.7° 2.9°
LF-30 4.2° 6.7° 8.2° 12.2° 14.7° LF-30 2.3° 2.8° 3.0° 3.5° 3.6°
LJ-20 2.5° 4.7° 7.7° 9.6° LJ-20 1.9° 2.5° 3.1° 3.4°
LJ-30 5.0° 7.8° 9.5° 13.9° 16.6° LJ-30 2.6° 3.1° 3.4° 3.8° 4.0°
LL-30 2.9° 5.5° 9.1° 11.4° LL-30 2.1° 2.9° 3.6° 4.0°
LL-40 5.5° 9.1° 11.4° 16.9° 20.4° LL-40 2.8° 3.5° 3.8° 4.4° 4.6°
LSG-40 3.9° 7.0° 11.3° 14.0° LSG-40 2.7° 3.7° 4.7° 5.2°
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary Data
° High discharge temperature - additional cooling required

Condensing Temperature 40°C


Cooling Capacity (kW) Power Input (kW)
R407F R407F
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -30 -20 -10 -5 +5 +10 +15 Model -30 -20 -10 -5 +5 +10 +15
KM-5 0.6° 1.1° 1.9° KM-5 0.5° 0.7° 0.9°
KM-7 1.1° 1.9° 2.4° 3.8° 4.6° KM-7 0.7° 0.9° 0.9° 1.1° 1.1°
KJ-7 0.9° 1.6° 2.6° 3.2° KJ-7 0.7° 0.9° 1.2° 1.3°
KJ-10 1.6° 2.7° 3.4° 5.1° 6.2° KJ-10 1.0° 1.2° 1.3° 1.5° 1.5°
KSJ-10 1.2° 2.1° 3.3° 4.1° KSJ-10 0.9° 1.2° 1.5° 1.6°
KSJ-15 2.0° 3.4° 4.2° 6.3° 7.5° KSJ-15 1.2° 1.5° 1.7° 1.9° 1.9°
KL-15 1.3° 2.4° 3.9° 4.9° KL-15 1.0° 1.3° 1.7° 1.8°
KL-20 2.6° 4.1° 5.1° 7.5° 8.9° KL-20 1.4° 1.7° 1.8° 2.0° 2.1°
KSL-20 3.1° 4.9° 6.0° 8.9° 10.7° KSL-20 1.7° 2.1° 2.2° 2.5° 2.6°
LE-20 1.6° 3.1° 5.2° 6.4° 9.6° 11.6° LE-20 1.3° 1.8° 2.2° 2.4° 2.7° 2.9°
LF-20 2.3° 4.2° 6.9° 8.6° LF-20 1.7° 2.3° 2.8° 3.1°
LF-30 4.6° 7.2° 8.9° 13.0° 15.6° LF-30 2.4° 2.9° 3.1° 3.5° 3.7°
LJ-20 2.7° 5.1° 8.3° 10.4° LJ-20 2.0° 2.7° 3.3° 3.6°
LJ-30 5.3° 8.3° 10.2° 14.8° 17.7° LJ-30 2.8° 3.4° 3.6° 4.1° 4.3°
LL-30 3.2° 5.8° 9.5° 11.9° LL-30 2.3° 3.1° 4.0° 4.4°
LL-40 5.9° 9.7° 12.1° 18.0° 21.7° LL-40 3.0° 3.7° 4.1° 4.7° 4.9°
LSG-40 4.3° 7.6° 12.2° LSG-40 2.9° 4.0° 5.0°
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary Data
° High discharge temperature - additional cooling required

83 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Condensing Temperature 40°C

R448A/ Cooling Capacity (kW) R448A/ Power Input (kW)


R449A Evaporating Temperature (°C) R449A Evaporating Temperature (°C)
Model -30 -20 -10 -5 +5 +10 +15 Model -30 -20 -10 -5 +5 +10 +15
KM-5 0.7° 1.2° KM-5 0.5° 0.6°
KM-7 1.2° 1.9° 2.4° 3.5° 4.3° KM-7 0.7° 0.8° 0.9° 1.0° 1.0°
KJ-7 0.9° 1.6° KJ-7 0.7° 0.9°
KJ-10 1.6° 2.6° 3.2° 4.8° 5.7° KJ-10 1.0° 1.1° 1.2° 1.3° 1.4°
KSJ-10 1.3° 2.1° KSJ-10 1.0° 1.2°
KSJ-15 2.1° 3.3° 4.1° 6.0° 7.1° KSJ-15 1.2° 1.5° 1.6° 1.7° 1.7°
KL-15 1.5° 2.4° KL-15 1.0° 1.3°
LE-20 3.0° 5.0° 6.2° 5.3° 11.3° LE-20 1.5° 1.9° 2.0° 2.3° 2.4°
LF-30 4.4° 6.9° 8.4° 12.4° 14.8° LF-30 2.4° 2.9° 3.1° 3.5° 3.6°
LF-20 2.1° 3.8° LF-20 1.5° 2.0°
LJ-20 2.6° 4.7° LJ-20 1.7° 2.3°
LJ-30 4.7° 7.6° 9.4° 13.9° 16.6° LJ-30 2.5° 3.1° 3.3° 3.6° 3.7°
LL-30 6.1° LL-30 2.1° 3.0°
LL-40 5.9° 9.7° 12.0° 18.0° 21.7° LL-40 3.0° 3.6° 4.0° 4.5° 4.8°
LSG-40 4.4° 7.6° LSG-40 2.7° 3.7°
Conditions: Suction Gas Return 20°C / Subcooling 0K
Preliminary Data
° High discharge temperature - additional cooling required

GPC-EN-2024 REFRIGERATION APPLICATIONS 84


85 GPC-EN-2024 REFRIGERATION APPLICATIONS
Discus™ reciprocating compressor range
From 2, 3 and 8 cylinder semi-hermetic reciprocating compressors
for medium/low temperature refrigeration and high temperature
applications like process cooling or air-conditioning.

The key difference between Discus and traditional reciprocating


technologies lies in the valve plate design. The Discus valve plate
allows gas to flow into the cylinders with a minimum heat gain,
while suction cavities are designed to smoothly route the gas to
minimize losses. These effects lead to:
• Superior cooling capacity due to no re-expansion volume
• Up to 10% higher efficiency compared to conventional
“cost-effective” reed type compressors
Discus compressor
• Lower operating costs for the end-user

The Discus ranges from 5 to 60 hp with a displacement of 16.8 to


181. These compressors are qualified for R407A/F/C, R448A/R449A, • PTFE-coated bearings for especially low friction and good
R404A, R134a, R450A and R513A. All Discus compressors are protection at start-up
designed to deliver maximum performance and reliability: • Electronic motor protection module
• Discus “puck” valve integrated into the valve plate for highest • Availability of two motor sizes per displacement. The small
performance whatever the operating condition motor covers all refrigeration applications while the large
• Positive displacement high flow oil pump guarantees high oil motor can be used in comfort, process cooling or inverter
feeding pressure for good lubrication and bearings’ cooling applications

Discus compressor line-up

8D-Series

3D-Series

2D-Series

Displacement (m3/h)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

Features and benefits Operating envelope R404A


• Highest level of efficiency available on the market, 70
whatever the refrigerant and operating condition
• Integrated oil pump and Electronic Oil Pressure Switch 60
OPS2 for maximum reliability
Condensing Temperature °C

• Two motor sizes per displacement, optimized for different


50
applications
• Large operating envelope that allows medium and low
temperature applications to be covered by one single 40
model with condensing limit as low as 5°C
• Provide cooling capacity modulation either by cylinder 30
head blocked suction or with use of frequency inverters
from 25 to 60Hz 20
• Multi-refrigerant compressor range – one model to cover
all standard refrigerants
• Option to use 2 and 3 cylinder models with additional 10
Demand Cooling function in order to achieve extended
low temperature operating envelope without any 0
superheat restriction for new refrigerants R407A/F, R448A -55 -50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15
and R449A Evaporating temperature °C

Large Motor 20°C SGRT Large Motor 20°C SGRT + Fan


Maximum allowable pressure (PS)
Small Motor 20°C SGRT Small Motor 0°C SGRT + Fan

• Low Side PS 22.5 bar (g)/ High Side PS 28 bar (g) For individual model details please refer to Copeland Select software.

GPC-EN-2024 REFRIGERATION APPLICATIONS 86


Operating envelope R407A Operating envelope R407F
70 70

60 60
Condensing Temperature °C

Condensing Temperature °C
50 50

40 40

30 30

20 20

10 10

0 0
-40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15

Evaporating Temperature °C Evaporating Temperature °C

Large Motor 0°C SGRT Small Motor 20°C SGRT Large Motor 0°C SGRT Small Motor 20°C SGRT
Large Motor 20°C SGRT Small Motor 20°C Large Motor 20°C SGRT Small Motor 20°C SGRT
SGRT Demand cooling Small Motor 20K Suction Superheat Demand cooling
Small Motor 20K Suction Superheat

Operating envelope R448A/R449A Operating envelope R134a


70 90

80
60

70
Condensing Temperature °C

Condensing Temperature °C

50
60

40
50

30 40

30
20
20
10
10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 -20 -15 -10 -5 0 5 10 15 20 25 30

Evaporating Temperature °C Evaporating Temperature °C

Large Motor 20K Superheat Small Motor 20°C SGRT Large Motor 20°C SGRT
Large Motor 20°C SGRT Small Motor 20°C SGRT Small Motor 25°C SGRT
Small Motor 20K Suction Superheat Demand cooling Large Motor 20K Superheat

87 GPC-EN-2024 REFRIGERATION APPLICATIONS


Technical overview

@1 m - dB(A)***
Sound Pressure
Length/Width/
Displacement

Oil Quantity
Maximum

Net Weight
Motor Version/ Locked Rotor

Nominal

Height
(m3/h)
Operating

(mm)

(kg)
Code Current (A)

hp
Models

(l)
Current (A)

3 Ph** 3 Ph** 3 Ph**


2DC-50 5.0 16.8 2.3 590/330/470 132 AWM 9 55 65
2DD-50 5.0 19.3 2.3 590/330/470 132 AWM 10 55 65
2DL-40 4.0 23.7 2.3 590/330/470 131 AWM 11 55 64
2DL-75 7.5 23.7 2.3 590/330/470 136 AWM 13 70 66
2DB-50 5.0 28.0 2.3 590/330/470 131 AWM 13 55 64
2DB-75 7.5 28.0 2.3 590/330/470 136 AWM 16 70 66
3DA-50 5.0 32.2 3.7 655/370/480 146 AWM 15 55 69
3DA-75 7.5 32.2 3.7 680/370/480 152 AWM 17 106 69
3DC-75 7.5 38.0 3.7 655/370/480 150 AWM 18 70 71
3DC-100 10.0 38.0 3.7 680/370/480 164 AWM 20 121 70
3DS-100 10.0 49.9 3.7 680/370/480 162 AWM 24 121 70
3DS-150 15.0 49.9 3.7 710/370/490 166 AWM 29 125 70
8DH-500 50.0 151.0 7.6 835/475/610 330 AWM 88 458 79
8DL-370 37.0 151.0 7.6 835/475/610 323 AWM 74 349 76
8DJ-600 60.0 181.0 7.6 835/475/610 331 AWM 108 476 79
8DT-450 45.0 181.0 7.6 835/475/610 335 AWM 90 441 78
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data
Condensing Temperature: 40°C
Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
2DC-50 1.7 2.4 4.5 7.8 10.0 15.5 2DC-50 1.4 1.7 2.3 2.9 3.2 3.6
2DD-50 2.1 3.1 5.8 9.5 12.0 18.1 2DD-50 1.7 2.1 2.7 3.4 3.7 4.1
2DL-40 2.5* 3.7* 7.4 11.9 14.8 2DL-40 2.3* 2.7* 3.5 4.3 4.6
2DL-75 7.2 11.9 14.8 22.1 2DL-75 3.5 4.2 4.5 4.8
2DB-50 3.3* 4.6* 9.0 14.4 17.8 2DB-50 2.8* 3.3* 4.3 5.2 5.6
2DB-75 9.0 14.3 17.7 26.1 2DB-75 4.4 5.3 5.7 6.1
3DA-50 3.8* 5.4* 10.4 16.4 20.2 3DA-50 3.2* 3.8* 5.0 6.1 6.5
3DA-75 10.3 16.7 20.7 30.8 3DA-75 5.0 6.0 6.4 6.9
3DC-75 4.7* 6.5* 12.4 19.6 24.2 3DC-75 3.9* 4.6* 6.0 7.2 7.8
3DC-100 12.6 20.3 25.1 37.0 3DC-100 5.8 7.1 7.6 8.1
3DS-100 6.4* 9.1* 16.9 26.3 32.1 3DS-100 5.2* 6.1* 7.9 9.6 10.3
3DS-150 16.8 26.6 32.7 48.0 3DS-150 7.9 9.6 10.2 11.1
8DH-500 49.1 78.8 97.7 146.0 8DH-500 24.1 28.8 31.0 33.9
8DL-370 20.7* 28.8* 53.6 85.3 105.5 8DL-370 17.4* 19.8* 25.2 30.5 33.0
8DJ-600 60.3 95.5 118.0 174.5 8DJ-600 28.9 35.1 37.9 42.2
8DT-450 24.0* 32.6* 59.6 93.3 114.5 8DT-450 20.1* 23.2* 29.5 35.8 38.6
Conditions: Suction Gas Return 20°C / Subcooling 0K
* 10K Border

GPC-EN-2024 REFRIGERATION APPLICATIONS 88


Capacity data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R407F R407F
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
2DC-50 1.1* 1.9* 4.7 8.0 10.1 15.4 2DC-50 1.4* 1.7* 2.4 3.1 3.3 3.6
2DD-50 1.6* 2.6* 5.9 9.7 12.1 18.1 2DD-50 1.7* 2.1* 2.9 3.6 3.8 4.1
2DL-40 2.6* 3.9* 7.7 12.4 15.3 2DL-40 2.4* 2.8* 3.7 4.5 4.9
2DL-75 7.6 12.5 15.6 23.4 2DL-75 3.7 4.4 4.6 5.0
2DB-50 3.9* 5.4* 9.8 15.3 18.8 2DB-50 2.9* 3.4* 4.5 5.4 5.8
2DB-75 9.6 15.3 18.9 27.9 2DB-75 4.6 5.6 6.0 6.3
3DA-50 4.3* 6.1* 11.3 17.9 22.1 3DA-50 3.4* 4.0* 5.2 6.4 6.8
3DA-75 11.4 18.4 22.8 33.8 3DA-75 5.2 6.3 6.8 7.2
3DC-75 5.4* 7.5* 13.8 21.6 26.6 3DC-75 4.2* 4.8* 6.2 7.5 8.1
3DC-100 14.0 22.1 27.3 40.2 3DC-100 6.1 7.4 7.9 8.5
3DS-100 7.3* 10.2* 18.4 28.8 35.3 3DS-100 5.5* 6.4* 8.3 10.0 10.8
3DS-150 18.8 29.7 36.4 53.2 3DS-150 8.2 10.1 10.8 11.8
8DL-370 20.8* 28.9* 53.6 85.3 105.5 8DL-370 17.4* 19.8* 25.2 30.5 33.0
8DH-500 53.0 84.6 105.0 156.5 8DH-500 25.8 30.5 32.2 34.9
8DJ-600 63.7 101.0 125.0 187.5 8DJ-600 30.6 36.9 39.8 43.9
8DT-450 26.8* 35.9* 64.1 100.5 123.5 8DT-450 21.8* 24.7* 31.2 37.7 40.7
Conditions: Suction Gas Return 20°C / Subcooling 0K
* 10K Border

Condensing Temperature 40°C

R448A/ Cooling Capacity (kW) R448A/ Power Input (kW)


R449A Evaporating Temperature (°C) R449A Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
2DC-50 1.4* 2.4* 5.1 8.4 10.6 15.9 2DC-50 1.4* 1.7* 2.4 3.0 3.3 3.5
2DD-50 1.7* 2.7* 5.8 9.7 12.2 18.3 2DD-50 1.7* 2.0* 2.7 3.4 3.7 4.1
2DL-40 1.0* 2.7* 3.9* 7.5 12.2 15.2 2DL-40 1.5* 2.3* 2.7* 3.5 4.4 4.9
2DL-75 2.5* 3.7* 7.3 12.1 15.2 23.2 2DL-75 2.3* 2.7* 3.5 4.3 4.6 5.1
2DB-50 1.5* 3.6* 5.0* 9.2 14.7 18.2 2DB-50 2.0* 2.8* 3.3* 4.4 5.4 5.8
2DB-75 3.8* 5.2* 9.4 15.0 18.5 27.6 2DB-75 3.0* 3.5* 4.4 5.3 5.7 6.2
3DA-50 1.9* 4.1* 5.6* 10.2 16.1 19.8 3DA-50 2.3* 3.3* 3.9* 5.0 6.2 6.6
3DA-75 3.9* 5.8* 11.0 17.6 21.8 32.3 3DA-75 3.3* 4.0* 5.2 6.1 6.5 6.8
3DC-75 2.7* 5.1* 6.9* 12.4 19.4 23.8 3DC-75 2.9* 4.0* 4.6* 6.0 7.3 7.8
3DC-100 4.4* 6.9* 13.3 21.1 25.9 37.7 3DC-100 3.6* 4.4* 6.0 7.2 7.6 8.1
3DC-75 DC 2.6 5.4 7.3 12.4 19.5 23.9 3DC-75 DC 2.9 4.0 4.6 6.0 7.3 7.8
3DS-100 3.8* 7.1* 9.5* 16.9 26.5 32.5 3DS-100 4.0* 5.4* 6.2* 8.1 9.8 10.6
3DS-150 7.5* 10.2* 17.8 27.6 33.7 49.1 3DS-150 5.6* 6.4* 8.2 9.8 10.5 11.5
8DH-500 18.7* 27.4* 51.0 80.6 99.2 145.0 8DH-500 15.9* 18.8* 24.4 29.3 31.3 34.0
8DL-370 7.4* 18.4* 26.2* 49.3 79.0 97.6 8DL-370 11.5* 16.6* 19.3* 24.6 29.3 31.4
8DJ-600 24.2* 34.0* 61.7 96.9 119.0 174.5 8DJ-600 19.3* 22.5* 29.2 35.6 38.4 42.9
8DT-450 12.2* 25.4* 34.7* 62.0 97.7 120.0 8DT-450 14.9* 20.1* 23.2* 29.6 36.0 38.8
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

89 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R404A R404A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
2DC-50 2.1° 3.0° 5.4 8.8 11.0 16.5 2DC-50 1.7° 2.1° 2.7 3.3 3.6 3.8
2DD-50 2.8° 3.9° 6.8 10.8 13.2 19.3 2DD-50 2.2° 2.5° 3.3 3.9 4.1 4.3
2DL-40 1.2* 3.8 5.1 8.5 13.2 16.2 2DL-40 1.8* 2.7 3.2 4.1 4.9 5.3
2DL-75 3.6° 4.9° 8.4 13.4 16.5 24.1 2DL-75 2.7° 3.1° 4.0 4.8 5.1 5.5
2DB-50 1.7* 4.6 6.2 10.4 16.0 19.4 2DB-50 2.2* 3.2 3.8 4.9 5.9 6.3
2DB-75 4.9° 6.4° 10.5 16.2 19.8 28.6 2DB-75 3.5° 4.0° 5.1 6.1 6.5 7.0
3DA-50 2.0* 5.7 7.4 11.9 17.9 21.7 3DA-50 2.7* 4.0 4.7 5.9 6.9 7.3
3DA-75 5.2° 7.2° 12.2 18.9 23.1 33.4 3DA-75 3.9° 4.6° 5.9 6.9 7.3 7.6
3DC-75 2.8* 7.0 9.1 14.4 21.6 26.1 3DC-75 3.4* 4.9 5.6 7.0 8.2 8.7
3DC-100 6.6° 8.9° 14.9 22.7 27.5 39.3 3DC-100 4.6° 5.4° 6.9 8.1 8.5 8.9
3DS-100 4.0* 9.6 12.5 19.8 29.5 35.5 3DS-100 4.7* 6.5 7.5 9.4 11.1 11.7
3DS-150 9.1° 12.2° 19.9 30.2 36.5 51.9 3DS-150 6.3° 7.4° 9.4 11.1 11.6 12.0
8DH-500 26.3° 35.7° 58.8 89.3 108.0 153.5 8DH-500 19.1° 22.1° 27.9 32.8 34.7 37.3
8DL-370 10.8* 28.0 36.9 59.3 88.8 106.5 8DL-370 13.2* 19.5 22.4 27.9 32.7 34.7
8DJ-600 32.7° 44.0° 71.3 107.0 128.5 181.0 8DJ-600 23.0° 26.8° 33.7 39.5 41.9 45.5
8DT-450 14.2* 34.7 44.9 70.6 105.0 125.5 8DT-450 16.9* 23.7 27.2 34.0 40.2 42.8
Conditions: Suction Gas Return 20°C / Subcooling 0K
° High Discharge Temperature - Additional Cooling Required
* 10K Border

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
2DC-50 2.4* 4.7* 6.3* 10.3 2DC-50 1.5* 2.0* 2.1* 2.3
2DD-50 3.1* 5.8* 7.6* 12.2 2DD-50 1.9* 2.3* 2.5* 2.7
2DL-40 4.0 7.2 9.2 14.4 2DL-40 2.3 2.8 3.1 3.4
2DL-75 3.6* 6.8* 8.9* 14.3 2DL-75 2.1* 2.7* 3.0* 3.3
2DB-50 5.2 9.1 11.6 17.9 2DB-50 2.6 3.3 3.6 4.0
2DB-75 4.5* 8.2* 10.6* 17.0 2DB-75 2.6* 3.3* 3.5* 3.9
3DA-50 6.0 10.2 12.9 19.8 3DA-50 3.0 3.7 4.0 4.4
3DA-75 5.1* 9.6* 12.5* 20.1 3DA-75 3.1* 3.8* 4.1* 4.5
3DC-75 7.4 12.5 15.7 23.9 3DC-75 3.6 4.5 4.8 5.3
3DC-100 6.8* 12.0* 15.3* 24.2 3DC-100 3.7* 4.5* 4.8* 5.2
3DS-100 9.7 16.2 20.4 31.0 3DS-100 4.7 5.9 6.4 7.2
3DS-150 9.7* 16.3* 20.6* 31.7 3DS-150 5.0 6.2* 6.6* 7.3
8DH-500 28.6* 47.9* 60.9* 95.6 8DH-500 15.5* 18.8* 20.2* 22.2
8DJ-600 34.4* 57.5* 72.9* 114.0 8DJ-600 18.1* 22.2* 24.0* 26.8
8DL-370 31.4 51.6 64.5 97.3 8DL-370 15.1 18.5 19.9 22.2
8DT-450 38.7 62.1 77.1 115.0 8DT-450 18.4 22.5 24.4 27.5
Conditions: Suction Gas Return 20°C / Subcooling 0K
* 10K Border

GPC-EN-2024 REFRIGERATION APPLICATIONS 90


91 GPC-EN-2024 REFRIGERATION APPLICATIONS
Copeland Compressor Electronics for
Copeland Stream semi-hermetic compressors

Copeland compressor electronics monitor and interpret data inside


the compressor in order to enhance the reliability and operational
performance of HVACR systems. Built upon the success of CoreSense
Diagnostics introduced a few years ago, Copeland is now introducing the
next generation electronics module for Stream compressors featuring a
modular design using state-of-the-art electronics. This modular design
with plug-in modules gives the customers the flexibility to choose the
advanced features as per their system requirements. These features
include advanced protection and diagnostics, Bluetooth and Modbus
communication for remote monitoring, liquid injection control, dynamic
envelope monitoring, digital and capacity control etc.

The benefits of Copeland compressor electronics go beyond compressor Copeland compressor electronic module
protection by assisting in system diagnosis and optimization. Providing
service engineers with detailed information at the right time, system-related
problems can be diagnosed faster or even before they occur. Optional
plug-in modules with advanced control features and factory mounted
sensors reduce the system complexity and applied costs for system
manufacturers. Supermarket operators benefit from increased system
uptime, reduction in food loss and reduced maintenance costs.

Technical specification Benefits

• Power supply 115/230VAC • Modularity for customer flexibility


• Communication protocol (Modbus® RTU and Bluetooth®) • Optional plug-in modules with different functionalities
• Bus to system controller: RS 485 • Advanced protection for reliable system operation
• Discharge temperature sensor • Diagnostics for quicker troubleshooting
• Current sensor • Power monitoring for operational costs monitoring
• Flash memory • Communication options - Bluetooth and Modbus for
• Alarm reset button remote monitoring
• Compressor control for reduced system applied costs

Functions of modules

2 4

1 Base board

1 Head fan and


2 liquid injection control

Digital modulation control and


3 unloaded start

4 Modbus®

GPC-EN-2024 REFRIGERATION APPLICATIONS 92


Scope of supply

5
3
1

2
4

1 Optional plug-in modules

2 Discharge temperature sensor

3 Current sensor

4 Oil pressure switch

5 Communication port

93 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland Stream semi-hermetic reciprocating compressors
with Compressor Electronics for HFC / HFO blends
Stream series 4 and 6 cylinder compressors provide best-in-class performance,
thereby significantly reducing the cost of operation and environmental
impact compared to competing products. They are equipped with Copeland
compressor electronics technology, featuring a modular design using state-of-
the-art electronics (p.92). With advanced protection and diagnostics features
for system relia bility, reduced service costs and increased equipment uptime,
Stream series is built to last in today’s modern changing world.
Copeland Stream compressors are now qualified for low GWP refrigerants
classified A2L, such as R454A, R454C and R455A.

Copeland Stream compressor


Stream compressor line-up
Stream 6 Cylinder

Stream 4 Cylinder

Displacement (m3/h)
50 60 70 80 90 100 110 120 130 140 150 160

Features and benefits Copeland Compressor Electronics


Technology features
• Range of 16 models from 62 to 153m3/h
• Best-in-class seasonal efficiencies, up to 15% higher than • Motor and oil protection
market standard
• Storage of compressor asset and advanced runtime
• Multi-refrigerant compressor, compatible with R407A/F/C, information
R448A/ R449A, R404A, R134a, R450A, R513A, R454A,
• Runtime/alarm signalling using multi-colour LED
R454C and R455A.
flash-codes
• Stepless capacity modulation by means of inverter
• Communication to system controller via Bluetooth
or digital modulation
or Modbus®
• Wide operating envelope covering low- and medium-
• Individual compressor power monitoring
temperature refrigeration without cooling fan
• Reduced sound level, dimensions and weight by up to 45 kg
• Option to use compressors with additional demand cooling
function in order to achieve extended low temperature
operating envelope without any superheat restriction for new
refrigerants R407A/F, R448A and R449A

Operating envelope R454A


With small motor With large motor
70 70

60 60
Condensing Temperature °C

Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
20
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15
Condensing Temperature °C Condensing Temperature °C
10K Suction Superheat 10K Suction Superheat
0°C Suction Gas Return 0°C Suction Gas Return
20°C Suction Gas Return 20°C Suction Gas Return

GPC-EN-2024 REFRIGERATION APPLICATIONS 94


Operating envelope R454C
With small motor With large motor

70 70
Condensing Temperature °C

Condensing Temperature °C
60 60

50 50

40 40

30 30

20 20

10 10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20
Condensing Temperature °C Condensing Temperature °C
10K Suction Superheat 10K Suction Superheat
0°C Suction Gas Return 0°C Suction Gas Return
20°C Suction Gas Return 20°C Suction Gas Return

Operating envelope R455A


With small motor With large motor

70 70
Condensing Temperature °C

Condensing Temperature °C

60 60

50 50

40 40

30 30

20 20

10 10

0 0
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20
Condensing Temperature °C Condensing Temperature °C
10K Suction Superheat 10K Suction Superheat
0°C Suction Gas Return 0°C Suction Gas Return
20°C Suction Gas Return 20°C Suction Gas Return

Operating envelope R448A/R449A


With small motor With large motor
70 70

60 60
Condensing Temperature °C

Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15
Evaporating Temperature °C Evaporating Temperature °C

20K Suction Superheat 0°C Suction gas return 20K Suction Superheat 0°C Suction Gas Return
20°C Suction Gas Return 20°C Suction Gas Return

95 GPC-EN-2024 REFRIGERATION APPLICATIONS


Technical overview

Sound Pressure
Maximum

Length/width/
Displacement

@1 m - dB(A)
Oil Quantity
Motor Version/ Locked Rotor

Net Weight
Operating Current
Nominal
Code Current (A)

height
(m3/h)

(mm)

(kg)
(A)

***
hp
Models

(l)
3 Ph** 3 Ph** 3 Ph**

4MF-13 13 61.7 3.3 638/501/452 177 AWM 30.8 105 70

4MA-22 22 61.7 3.3 638/501/452 177 AWM 36.3 175 75

4ML-15 15 71.4 3.3 638/501/452 180 AWM 35.4 156 71

4MH-25 25 71.4 3.3 657/501/452 187 AWM 41.6 199 75

4MM-20 17 78.2 3.3 657/501/452 182 AWM 39.0 175 71

4MI-30 27 78.2 3.3 657/501/452 188 AWM 46.6 221 75

4MT-22 22 87.7 3.3 657/501/452 183 AWM 44.5 175 73

4MJ-33 33 87.7 3.3 657/501/452 190 AWM 52.9 221 74

4MU-25 25 99.4 3.3 657/501/452 186 AWM 51.9 199 72

4MK-35 32 99.4 3.3 688/501/452 202 AWM 61.1 255 74

6MM-30 27 120.5 3.3 695/547/450 215 AWM 59.7 255 78

6MI-40 35 120.5 3.3 695/547/450 219 AWM 71.4 304 78

6MT-35 32 135.0 3.3 725/547/450 221 AWM 67.3 255 77

6MJ-45 40 135.0 3.3 725/547/450 223 AWM 81.5 304 79

6MU-40 40 153.0 3.3 757/547/450 225 AWM 75.8 306 78

6MK-50 50 153.0 3.3 773/547/450 230 AWM 92.9 393 80


** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

GPC-EN-2024 REFRIGERATION APPLICATIONS 96


Capacity data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R454A R454A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
4MF-13 8.8* 12.2* 21.8 33.4 40.5 4MF-13 7.0* 8.2* 8.2 12.6 13.5
4MA-22 9.1* 12.6* 22.4 34.8 42.7 62.3 4MA-22 7.1* 8.2* 8.2 12.4 13.3 14.3
4ML-15 11.1* 15.0* 26.2 40.2 49.0 4ML-15 8.5* 9.9* 9.9 14.9 15.9
4MH-25 10.8* 14.7* 26.2 40.6 49.7 72.0 4MH-25 8.1* 9.5* 9.5 14.5 15.4 16.6
4MM-20 12.5* 16.7* 28.9 44.4 54.3 4MM-20 9.5* 11.0* 11.0 16.5 17.7
4MI-30 12.0* 16.5* 29.1 44.7 54.4 78.2 4MI-30 9.2* 10.8* 10.8 16.2 17.3 18.8
4MT-22 13.8* 18.4* 31.8 48.5 59.0 4MT-22 10.9* 12.6* 12.6 18.9 20.2
4MJ-33 13.5* 18.8* 33.1 50.5 61.4 88.1 4MJ-33 10.3* 12.1* 12.1 18.3 19.5 21.3
4MU-25 15.6* 20.9* 36.3 55.5 67.6 4MU-25 12.0* 13.9* 13.9 21.3 23.0
4MK-35 15.7* 21.2* 36.9 56.4 68.7 99.4 4MK-35 12.0* 13.9* 13.9 21.1 22.6 24.9
6MM-30 18.9* 25.4* 44.4 67.7 82.1 6MM-30 14.5* 16.8* 16.8 25.5 27.3
6MI-40 18.3* 25.0* 44.2 68.0 83.0 120.5 6MI-40 14.2* 16.6* 16.6 25.1 26.8 29.2
6MT-35 22.0* 28.4* 49.6 76.0 92.5 133.5 6MT-35 16.6* 18.6* 18.6 28.3 30.2 33.0
6MJ-45 21.1* 29.1* 49.7 75.4 91.5 6MJ-45 16.0* 19.1* 19.1 28.9 30.9
6MU-40 23.3* 31.3* 54.9 83.4 101.0 6MU-40 18.0* 20.9* 20.9 32.4 34.8
6MK-50 23.3* 31.3* 54.7 83.8 102.0 148.0 6MK-50 18.5* 21.2* 21.2 31.8 34.0 37.3
Conditions: Suction Gas Return 20°C / Subcooling 0K, 100% loaded
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R454C R454C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
4MF-13 7.3* 11.3 18.9 29.4 36.0 4MF-13 5.7* 6.7 8.6 10.3 11.1
4MA-22 6.9* 11.2 19.3 30.4 37.4 54.3 4MA-22 5.7* 6.8 8.7 10.4 11.0 11.8
4ML-15 8.5* 13.2 21.8 33.9 41.4 - 4ML-15 6.9* 8.0 10.2 12.2 13.1 -
4MH-25 8.3* 12.9 21.6 34.0 41.8 61.2 4MH-25 6.6* 7.7 10.0 12.0 12.8 13.9
4MM-20 9.7* 14.7 24.1 37.3 45.6 - 4MM-20 7.7* 8.9 11.3 13.6 14.5 -
4MI-30 9.1* 14.4 24.1 37.6 46.1 66.8 4MI-30 7.5* 8.8 11.3 13.4 14.3 15.6
4MT-22 10.4* 15.9 26.0 40.2 49.0 - 4MT-22 8.7* 10.2 13.0 15.6 16.7 -
4MJ-33 10.2* 16.2 27.5 42.7 52.1 75.0 4MJ-33 8.4* 9.9 12.8 15.2 16.2 17.7
4MU-25 11.9* 18.3 30.3 46.9 57.2 - 4MU-25 9.8* 11.4 14.6 17.7 19.1 -
4MK-35 11.9* 18.6 30.8 47.6 58.1 84.2 4MK-35 9.7* 11.4 14.6 17.3 18.5 20.5
6MM-30 14.5* 22.2 36.8 57.1 69.7 - 6MM-30 11.7* 13.6 17.4 20.9 22.5 -
6MI-40 14.2* 22.0 36.7 57.2 70.0 102.0 6MI-40 11.7* 13.6 17.4 20.8 22.2 24.3
6MT-35 17.1* 25.5 41.5 63.7 77.6 - 6MT-35 13.5* 15.5 19.8 23.7 25.4 -
6MJ-45 16.2* 24.7 40.8 63.4 77.6 113.0 6MJ-45 13.0* 15.1 19.4 23.3 24.9 27.2
6MU-40 17.6* 27.1 44.7 69.4 84.7 - 6MU-40 14.6* 17.0 21.9 26.7 28.7 -
6MK-50 17.5* 27.2 45.0 70.1 85.8 124.5 6MK-50 15.1* 17.3 22.0 26.3 28.2 31.1
Conditions: Suction Gas Return 20°C / Subcooling 0K, 100% loaded
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary data

97 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R455A R455A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
4MF-13 7.4 10.4* 19.4 30.1 36.7 4MF-13 7.4 7.1* 9.2 11.1 11.9
4MA-22 7.1 11.7 20.1 31.7 38.9 56.5 4MA-22 7.1 7.2 9.4 11.2 11.9 12.8
4ML-15 9.5 13.0* 23.6 36.7 44.9 4ML-15 9.5 8.6* 11.0 13.1 14.1
4MH-25 9.2 14.1 23.6 37.1 45.6 66.6 4MH-25 9.2 8.2 10.7 12.8 13.7 14.9
4MM-20 10.7 14.6* 26.1 40.4 49.5 4MM-20 10.7 9.5* 12.1 14.6 15.6
4MI-30 10.3 16.0 26.8 41.4 50.5 72.7 4MI-30 10.3 9.4 12.1 14.4 15.3 16.8
4MT-22 11.5 15.6* 28.2 43.6 53.2 4MT-22 11.5 10.9* 13.9 16.7 17.9
4MJ-33 11.3 17.7 29.8 46.4 56.6 81.4 4MJ-33 11.3 10.6 13.6 16.2 17.3 19.0
4MU-25 13.4 18.5* 33.3 51.3 62.6 4MU-25 13.4 12.2* 15.6 19.0 20.5
4MK-35 13.1 20.1 33.5 51.9 63.3 91.5 4MK-35 13.1 12.1 15.5 18.5 19.8 22.0
6MM-30 16.4 22.3* 40.4 62.6 76.3 6MM-30 16.4 14.6* 18.7 22.5 24.1
6MI-40 15.4 23.5 39.0 60.8 74.6 109.0 6MI-40 15.4 14.5 18.6 22.2 23.8 26.1
6MT-35 18.9 25.4* 45.1 69.1 84.1 6MT-35 18.9 16.6* 21.2 25.5 27.3
6MJ-45 18.2 27.1 44.6 69.3 84.9 123.5 6MJ-45 18.2 16.1 20.8 25.0 26.7 29.3
6MU-40 20.2 27.4* 49.8 77.2 94.2 6MU-40 20.2 18.1* 23.5 28.6 30.8
6MK-50 19.9 30.2 50.0 77.8 95.3 138.5 6MK-50 19.9 18.5 23.5 28.2 30.2 33.4
Conditions: Suction Gas Return 20°C / Subcooling 0K, 100% loaded
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary data

Condensing Temperature 40°C

R448A/ Cooling Capacity (kW) R448A/ Power Input (kW)


R449A Evaporating Temperature (°C) R449A Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 5 Model -45 -35 -30 -20 -10 -5 5
4MA-22 7.8* 11.3* 21.2 34.3 42.7 63.5 4MA-22 6.2* 7.4* 9.8 11.8 12.6 13.7
4MF-13 3.8* 8.2* 11.1* 19.6 30.4 37.3 4MF-13 4.5* 6.3* 7.4* 9.8 12.2 13.1
4MH-25 9.4* 13.5* 24.7 39.1 48.0 70.3 4MH-25 7.6* 8.9* 11.6 14.1 15.1 16.7
4ML-15 4.3* 10.5* 14.3* 25.2 38.7 47.1 4ML-15 5.2* 7.6* 8.9* 11.6 14.2 15.4
4MI-30 10.8* 15.4* 28.1 44.1 54.0 78.6 4MI-30 8.2* 9.8* 13.0 15.6 16.7 18.2
4MM-20 4.9* 11.8* 16.0* 27.8 42.5 51.5 4MM-20 5.8* 8.5* 9.9* 12.9 15.6 16.9
4MJ-33 12.1* 17.0* 30.9 48.7 59.8 87.6 4MJ-33 9.2* 11.0* 14.5 17.6 18.9 20.6
4MT-22 5.9* 13.5* 18.2* 31.3 47.7 57.8 4MT-22 6.6* 9.7* 11.3* 14.6 17.8 19.2
4MK-35 13.7* 19.2* 34.7 54.8 67.5 98.9 4MK-35 10.7* 12.7* 16.7 20.4 22.0 24.4
4MU-25 6.5* 14.3* 19.5* 34.2 53.2 65.1 4MU-25 7.4* 10.8* 12.7* 16.6 20.5 22.4
6MI-40 17.1* 23.9* 42.8 66.6 81.4 118.0 6MI-40 13.0* 15.3* 19.6 23.5 25.2 28.0
6MM-30 6.6* 17.6* 24.1* 41.8 63.2 76.3 6MM-30 8.8* 13.1* 15.4* 19.9 23.9 25.6
6MT-35 7.5* 19.8* 26.9* 46.5 70.0 84.3 6MT-35 9.7* 14.6* 17.2* 22.2 26.9 29.0
6MJ-45 19.5* 27.2* 48.1 74.5 91.0 132.0 6MJ-45 14.3* 17.0* 22.2 26.9 28.8 31.7
6MK-50 21.1* 29.4* 52.7 82.2 101.0 147.0 6MK-50 16.4* 19.2* 25.0 30.3 32.7 36.7
6MU-40 8.3* 22.2* 30.5* 53.4 81.8 99.4 6MU-40 10.9* 16.3* 19.1* 24.6 29.8 32.1

Conditions: Suction Gas Return 20°C / Subcooling 0K


* Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 98


99 GPC-EN-2024 REFRIGERATION APPLICATIONS
Copeland Stream digital with Compressor Electronics for
continuous capacity modulation

Stream digital series 4 and 6 cylinder compressors provide an


alternative means of continuous modulation to inverter. Digital
modulation is the most simple and precise method of capacity control
and helps to contain applied costs associated with modulation.

Digital technology is based on controlling a high-cycle solenoid valve


fitted on one of the cylinder heads based on cycle time. The valve
actuates a piston that controls the flow of gas into the suction area of
the Stream valve plate. The compressor always run at constant speed
which resolves the challenges related to oil return, mechanical and
electrical stress on the system.

All compressors are equipped with Copeland compressor electronics


technology (p.92) and offer the possibility to diagnose system-related
Copeland Stream digital compressor
problems faster or even before they occur.

Stream digital line-up

Stream 6 Cylinder

Stream 4 Cylinder

Displacement (m3/h)
50 60 70 80 90 100 110 120 130 140 150 160

Features and benefits


• Range of 16 models from 62 to 153 m3/h
• Multi-refrigerant compressor, compatible with R407A/F/C,
R448A/ R449A, R404A, R134a, R450A and R513A
• Continuous modulation from 50–100% (4-cylinder) and
33–100% (6-cylinder) ensuring a perfect match of capacity
and power to refrigeration load
• Economical and reliable alternative to frequency inverters
• Precise suction pressure control with associated energy
savings and stable evaporating temperatures
• Quick and easy integration into refrigeration equipment, similar
to any other standard compressor
• Possibility to easily retrofit existing installations with digital
cylinder head kit
• No vibrations or mechanical stress on system piping and
compressor parts
• Reduced compressor cycling for longer contactor and
compressor life
• Copeland compressor electronics module providing advanced
protection, diagnostics and preventive maintenance

GPC-EN-2024 REFRIGERATION APPLICATIONS 100


Operating envelope R448A/R449A

With 4 cylinder small motor - 100% modulation With 6 cylinder large motor - 100% modulation
70 70

60 60
Condensing Temperature °C

Condensing Temperature °C
50 50

40 40

30 30

20 20

10 10

0 0
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15
Evaporating Temperature °C Evaporating Temperature °C

20K Suction Superheat 20K Suction Superheat


20°C Suction Gas Return 20°C Suction Gas Return
0°C Suction Gas Return 0°C Suction Gas Return

With 4 cylinder small motor - 50% modulation With 6 cylinder large motor - 33% modulation
70 70

60 60
Condensing Temperature °C

Condensing Temperature °C

50 50

40 40

30 30

20 20

10 10

0 0
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15
Evaporating Temperature °C Evaporating Temperature °C

20K Suction Superheat 20K Suction Superheat


20°C Suction Gas Return 20°C Suction Gas Return
0°C Suction Gas Return 0°C Suction Gas Return

All other refrigerant envelopes are available as ‘Dynamic Envelopes’ and can be accessed through Copeland Select Software.

101 GPC-EN-2024 REFRIGERATION APPLICATIONS


Technical overview

Sound Pressure
Length/Width/
Displacement
Maximum

@1 m - dB(A)
Oil Quantity

Net Weight
Motor Version/ Locked Rotor

Nominal
Operating Current

Height
(m3/h)

(mm)
Code Current (A)

(kg)

***
hp
Models (A)

(l)
3 Ph** 3 Ph** 3 Ph**

4MFD-13 13 61.7 3.3 638/501/452 183 AWM 30.8 105 70


4MAD-22 22 61.7 3.3 638/501/452 183 AWM 36.3 175 75
4MLD-15 15 71.4 3.3 638/501/452 186 AWM 35.4 156 71
4MHD-25 25 71.4 3.3 657/501/452 193 AWM 41.6 199 75
4MMD-20 17 78.2 3.3 657/501/452 188 AWM 39.0 175 71
4MID-30 27 78.2 3.3 657/501/452 194 AWM 46.6 221 75
4MTD-22 22 87.7 3.3 657/501/452 189 AWM 44.5 175 73
4MJD-33 33 87.7 3.3 657/501/452 196 AWM 52.9 221 74
4MUD-25 25 99.4 3.3 657/501/452 192 AWM 51.9 199 72
4MKD-35 32 99.4 3.3 688/501/452 202 AWM 61.1 255 74
6MMD-30 27 120.5 3.3 695/547/450 221 AWM 59.7 255 78
6MID-40 35 120.5 3.3 695/547/450 225 AWM 71.4 304 78
6MTD-35 32 135.0 3.3 725/547/450 227 AWM 67.3 255 77
6MJD-45 40 135.0 3.3 725/547/450 229 AWM 81.5 304 79
6MUD-40 40 153.0 3.3 757/547/450 231 AWM 75.8 304 78
6MKD-50 50 153.0 3.3 773/547/450 236 AWM 92.9 393 80
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

GPC-EN-2024 REFRIGERATION APPLICATIONS 102


Capacity data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
4MFD-13 18.3* 30.9 37.9 4MFD-13 9.7* 11.8 12.7
4MAD-22 32.2 39.9 59.3 4MAD-22 11.7 12.6 14.0
4MLD-15 22.7* 37.7 46.1 4MLD-15 11.4* 13.8 14.9
4MHD-25 37.4 46.2 68.5 4MHD-25 13.7 14.6 15.9
4MMD-20 24.9* 41.2 50.5 4MMD-20 12.7* 15.3 16.5
4MID-30 21.6* 37.4 46.2 68.5 4MID-30 11.4* 13.7 14.6 15.9
4MTD-22 26.5* 44.2 54.2 4MTD-22 14.5* 17.5 18.9
4MJD-33 41.7 51.4 75.7 4MJD-33 15.1 16.1 17.8
4MUD-25 30.1* 50.4 61.8 4MUD-25 16.2* 19.9 21.6
4MKD-35 52.1 64.1 94.2 4MKD-35 19.5 20.9 23.4
6MMD-30 20.9* 39.3 61.3 75.0 6MMD-30 14.9* 19.4 23.6 25.5
6MID-40 40.4 63.6 78.3 115.5 6MID-40 19.3 23.3 25.0 27.6
6MTD-35 24.8* 45.3 70.3 86.0 6MTD-35 16.8* 21.9 26.9 29.1
6MJD-45 45.0 70.7 87.0 128.0 6MJD-45 21.5 26.1 28.0 31.0
6MUD-40 50.4 78.7 96.7 6MUD-40 24.4 30.1 32.8
6MKD-50 50.1 78.6 96.6 142.0 6MKD-50 24.4 29.8 32.3 36.4
Conditions: Suction Gas Return 20°C, Subcooling 0K, 100% Loaded
* Conditions: Suction Superheat 10K, Subcooling 0K

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R407F R407F
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Models -45 -35 -30 -20 -10 -5 +5
4MAD-22 20.5* 34.4 42.6 63.1 4MAD-22 10.2* 12.4 13.2 14.4
4MFD-13 19.5* 32.2 39.5 4MFD-13 10.2* 12.4 13.3
4MHD-25 23.9* 40.0 49.4 73.1 4MHD-25 11.9* 14.4 15.4 16.8
4MLD-15 23.9* 39.4 48.4 4MLD-15 12.0* 14.6 15.7
4MID-30 26.6* 44.0 54.2 79.9 4MID-30 13.1* 15.8 17.0 18.6
4MMD-20 26.3* 43.0 52.9 4MMD-20 13.3* 16.0 17.2
4MJD-33 29.8* 49.0 60.3 88.9 4MJD-33 14.8* 17.8 19.2 21.1
4MTD-22 29.5* 48.0 58.9 4MTD-22 15.1* 18.3 19.7
4MKD-35 33.3* 54.8 67.6 100.0 4MKD-35 16.8* 20.4 22.0 24.4
4MUD-25 32.9* 54.0 66.3 4MUD-25 17.1* 21.0 22.8
6MID-40 40.7* 67.2 82.6 121.5 6MID-40 20.2* 24.4 26.2 28.9
6MMD-30 40.2* 65.4 79.9 6MMD-30 20.4* 24.8 26.7
6MJD-45 45.3* 74.5 91.6 135.0 6MJD-45 22.9* 27.6 29.7 32.8
6MTD-35 45.3* 73.3 89.5 6MTD-35 23.1* 28.0 30.3
6MKD-50 50.7* 83.7 103.0 151.5 6MKD-50 25.8* 31.3 33.7 37.5
6MUD-40 47.9* 81.9 100.5 6MUD-40 25.9* 31.7 34.4
Conditions: Suction Gas Return 20°C, Subcooling 0K, 100% Loaded
* Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

103 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R404A R404A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
4MAD-22 8.1* 11.7* 23.4 35.6 43.1 61.3 4MAD-22 7.3* 8.6* 11.0 13.0 13.7 14.7
4MFD-13 8.3* 11.5* 22.6 34.5 41.8 4MFD-13 7.4* 8.7* 11.0 13.1 13.9
4MHD-25 9.6* 13.7* 27.2 41.7 50.7 72.9 4MHD-25 8.6* 10.1* 13.0 15.4 16.3 17.5
4MLD-15 10.6* 14.5* 27.6 41.6 50.2 4MLD-15 9.0* 10.5* 13.3 15.8 16.7
4MID-30 11.4* 16.2* 30.9 46.3 55.7 78.7 4MID-30 9.8* 11.5* 14.5 17.0 18.0 19.5
4MMD-20 12.2* 16.4* 30.6 45.6 54.8 4MMD-20 10.1* 11.6* 14.6 17.1 18.2
4MJD-33 12.9* 17.8* 34.2 51.9 62.7 89.5 4MJD-33 10.9* 12.6* 16.1 19.0 20.2 21.8
4MTD-22 13.7* 18.4* 34.3 51.5 62.1 4MTD-22 11.5* 13.2* 16.6 19.5 20.7
4MKD-35 14.5* 20.0* 38.4 58.3 70.6 101.0 4MKD-35 12.6* 14.6* 18.5 22.0 23.5 25.7
4MUD-25 14.9* 20.1* 38.1 57.5 69.5 4MUD-25 12.9* 14.9* 18.8 22.3 23.7
6MID-40 17.3* 28.6° 46.2 70.1 84.9 121.5 6MID-40 15.2* 17.6° 22.2 26.1 27.7 30.1
6MMD-30 18.2* 29.0° 46.0 69.5 84.3 6MMD-30 15.7* 18.1° 22.5 26.3 27.8
6MJD-45 19.2* 32.0° 51.9 78.7 95.1 135.0 6MJD-45 16.8* 19.6° 24.9 29.5 31.4 33.9
6MTD-35 20.5* 32.7° 52.0 78.5 94.9 6MTD-35 17.5* 20.1° 25.3 29.7 31.5
6MKD-50 21.4* 36.0° 58.1 87.7 106.0 150.5 6MKD-50 19.4* 22.5° 28.3 33.5 35.9 39.9
6MUD-40 22.6* 36.5° 58.1 88.1 107.0 6MUD-40 19.7* 22.7° 28.5 33.6 35.8

Conditions: Suction Gas Return 20°C, Subcooling 0K, 100% Loaded


* Conditions: Suction Superheat 10K, Subcooling 0K
° Additional Cooling Required

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
4MAD-22 4.0* 6.2* 11.8* 20.0* 25.4* 39.7 4MAD-22 3.7* 4.4* 5.9* 7.3* 7.9* 8.7
4MFD-13 12.1 20.2 25.4 38.5 4MFD-13 5.8 7.2 7.8 8.7
4MHD-25 4.4* 6.9* 13.5* 23.1* 29.3* 45.9 4MHD-25 4.7* 5.4* 7.1* 8.7* 9.4* 10.4
4MLD-15 14.8 24.2 30.2 45.5 4MLD-15 6.9 8.5 9.3 10.4
4MID-30 5.2* 8.0* 15.1* 25.4* 32.2* 50.2 4MID-30 4.9* 5.8* 7.6* 9.4* 10.3* 11.4
4MMD-20 16.5 26.7 33.3 49.8 4MMD-20 7.7 9.4 10.2 11.4
4MJD-33 6.0* 9.1* 17.0* 28.5* 35.9* 55.9 4MJD-33 5.6* 6.6* 8.7* 10.7* 11.5* 12.8
4MTD-22 18.9 30.3 37.7 56.7 4MTD-22 8.7 10.8 11.7 13.1
4MKD-35 7.0* 10.4* 19.1* 31.9* 40.3* 62.7 4MKD-35 7.1* 7.7* 9.7* 12.2* 13.3* 14.9
4MUD-25 20.5 33.5 41.9 63.2 4MUD-25 9.8 12.2 13.3 15.1
6MID-40 22.2* 37.6* 47.8* 75.3 6MID-40 12.0* 14.6* 15.8* 17.8
6MMD-30 24.9 40.3 50.2 75.3 6MMD-30 11.7 14.6 15.8 17.7
6MJD-45 25.6* 42.7* 54.0* 84.5 6MJD-45 13.0* 16.2* 17.8* 20.3
6MTD-35 28.2 45.5 56.5 84.4 6MTD-35 13.3 16.5 17.9 20.0
6MKD-50 26.2* 45.7* 58.6* 93.4 6MKD-50 15.2* 18.8* 20.5* 23.3
6MUD-40 31.2 50.1 62.3 93.6 6MUD-40 14.6 18.4 20.1 23.0
Conditions: Suction Gas Return 20°C, Subcooling 0K, 100% Loaded
* Conditions: Suction Superheat 10K, Subcooling 0K

GPC-EN-2024 REFRIGERATION APPLICATIONS 104


Capacity data

Condensing Temperature: 40°C

R448A / Cooling Capacity (kW) R448A / Power Input (kW)


R449A Evaporating Temperature (°C) R449A Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
4MAD-22 7.7* 11.1* 21.0 34.0 42.2 62.9 4MAD-22 6.2* 7.4* 9.8 11.8 12.6 13.7
4MFD-13 3.7* 8.1* 10.9* 19.4 30.1 36.9 4MFD-13 4.5* 6.3* 7.4* 9.8 12.2 13.1
4MLD-15 4.2* 10.3* 14.2* 24.9 38.3 46.6 4MLD-15 5.2* 7.6* 8.9* 11.6 14.2 15.4
4MHD-25 9.3* 13.3* 24.5 38.7 47.6 69.6 4MHD-25 7.6* 8.9* 11.6 14.1 15.1 16.7
4MMD-20 4.9* 11.6* 15.8* 27.5 42.0 51.0 4MMD-20 5.8* 8.5* 9.9* 12.9 15.6 16.9
4MID-30 10.6* 15.3* 27.8 43.6 53.5 77.8 4MID-30 8.2* 9.8* 13.0 15.6 16.7 18.2
4MJD-33 11.9* 16.8* 30.6 48.2 59.2 86.7 4MJD-33 9.2* 11.0* 14.5 17.6 18.9 20.6
4MTD-22 5.8* 13.3* 17.9* 31.0 47.2 57.2 4MTD-22 6.6* 9.7* 11.3* 14.6 17.8 19.2
4MKD-35 13.6* 19.0* 34.4 54.3 66.8 97.9 4MKD-35 10.7* 12.7* 16.7 20.4 22.0 24.4
4MUD-25 6.4* 14.2* 19.2* 33.9 52.7 64.4 4MUD-25 7.4* 10.8* 12.7* 16.6 20.5 22.4
6MID-40 16.9* 23.7* 42.4 65.9 80.6 116.5 6MID-40 13.0* 15.3* 19.6 23.5 25.2 28.0
6MMD-30 6.5* 17.4* 23.8* 41.4 62.6 75.5 6MMD-30 8.8* 13.1* 15.4* 19.9 23.9 25.6
6MTD-35 7.4* 19.5* 26.6* 46.0 69.3 83.5 6MTD-35 9.7* 14.6* 17.2* 22.2 26.9 29.0
6MJD-45 19.3* 26.9* 47.6 73.7 90.1 131.0 6MJD-45 14.3* 17.0* 22.2 26.9 28.8 31.7
6MKD-50 20.8* 29.1* 52.2 81.4 99.8 145.5 6MKD-50 16.4* 19.2* 25.0 30.3 32.7 36.7
6MUD-40 8.2* 21.9* 30.2* 52.9 81.0 98.4 6MUD-40 10.9* 16.3* 19.1* 24.6 29.8 32.1

Conditions: Suction Gas Return 20°C / Subcooling 0K, 100% Loaded


*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

105 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland Stream compressors with Compressor
Electronics for R744-transcritical applications

Stream series of 4 cylinder CO2 compressors is the ideal solution


for R744 booster systems. It is characterized by a design pressure
of 135 bar. Refrigerant flow and heat transfer have been optimized
for best performance. All compressors are equipped with Copeland
Compressor Electronics Module and offer the possibility to diagnose
system-related problems faster or even before they occur.

Copeland Stream compressor for R744

Stream compressor line-up

R744

Cooling Capacity (kW)


0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

Conditions: EN12900 R744: Evaporating -10°C, gas cooler exit: 35°C/ 90 bar, superheat: 10K

Features and benefits Operating envelope R744


130
Stream provides for flexibility in pack design and operation:
• Compact dimensions 120
• Integrated low pressure relief valve 110
• Discharge temperature protection
Discharge Pressure (bar)

• Service valve 360° rotation for ease of piping design 100


• 2 sight glasses for mounting of oil management control 90
and visual inspection
80
• One oil port for oil equalization in parallel system
• Oil splasher system ensuring lubrication at constant and 70
variable speed 60

50
Designed for durability and performance in R744 applications:
• Low sound, low vibration and large discharge chamber to 40
eliminate pulsation 30
• High design pressures of 135 bar (high side) and -25 -20 -15 -10 -5 0 5 10
90 bar (low side) Evaporating Temperature °C
• Burst pressures in excess of safety factor 3
• Cylinder head and discharge plenum design minimizing 10K Superheat 20K Superheat
heat transfer to suction side
• Stepless capacity modulation via inverter from 25 to 70Hz
• Copeland Compressor Electronics Technology
• Individual compressor power consumption monitoring

GPC-EN-2024 REFRIGERATION APPLICATIONS 106


Technical overview

Maximum

Net Weight (kg)

Sound Pressure
Oil Quantity (l)
Displacement

Capacity (kw)
Motor Version/ Locked Rotor

Nominal hp
Operating

dB(A)***
Code Current (A)

@1 m -
(m3/h)
Length/Width/ Current (A)

COP
Model
Height (mm)
3 Ph** 3 Ph** 3 Ph**

4MTL-05 5.0 4.6 8.8 1.6 1.5 630/425/410 123 EWL 13 80 59


4MTL-07 7.0 6.2 11.9 1.6 1.5 630/425/410 124 EWL 18 81 62
4MTL-09 9.0 7.4 14.6 1.6 1.5 630/425/410 123 EWL 21 93 63
4MTL-12 12.0 9.5 19.3 1.7 1.8 697/444/423 170 AWM 27 145 67
4MTL-15 15.0 12.5 25.2 1.8 1.8 697/445/422 170 AWM 35 156 71
4MTL-30 30.0 18.0 37.0 1.8 1.8 697/445/422 175 AWM 50 221 75
4MTL-35 35.0 22.7 44.9 1.8 2.8 821/486/466 264 AWM 60 304 74
4MTL-40 40.0 26.6 52.2 1.8 2.8 821/486/466 270 AWM 67 370 74
4MTL-50 50.0 32.0 65.9 1.8 2.8 821/486/466 276 AWM 83 393 74
Conditions EN12900 - MT: Evaporating -10°C , Suction Superheat 10K, Pressure 90 bar, Temperature 35°C
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

107 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Cooling Capacity (kW) Power Input (kW)

Pressure (bar)
Evaporating Temperature (°C) Evaporating Temperature (°C)

Temperature
-20 -15 -10 -5 0 -20 -15 -10 -5 0

(°C)
Model
Equivalent Evaporation Pressure (bar) Equivalent Evaporation Pressure (bar)
19.7 22.9 26.5 30.5 34.9 19.7 22.9 26.5 30.5 34.9
10 45 11.0 13.5 16.4 19.8 3.1 3.0 2.7 2.4
Condensing

15 50 9.9 12.3 14.9 18.0 21.5 3.4 3.4 3.2 3.0 2.6
20 57 8.8 10.9 13.3 16.1 19.3 3.8 3.8 3.7 3.5 3.2
25 64 7.6 9.5 11.6 14.1 16.9 4.1 4.2 4.1 4.0 3.8
4MTL-05
30 75 6.1 7.5 9.3 11.2 13.5 4.4 4.5 4.6 4.6 4.4
35 90 7.14 8.8 10.8 13.0 5.3 5.5 5.6 5.6
Cool gas

40 100 7.6 9.4 11.3 5.9 6.1 6.2


40 110 9.7 11.75 6.5 6.7
10 45 15.1 18.4 22.2 26.5 3.9 3.7 3.4 3.0
Condensing

15 50 13.7 16.7 20.2 24.1 28.6 4.4 4.3 4.1 3.7 3.3
20 57 12.2 14.9 18.1 21.6 25.7 4.8 4.8 4.7 4.5 4.1
25 64 10.5 13.0 15.7 18.8 22.4 5.3 5.4 5.3 5.2 4.9
4MTL-07
30 75 8.3 10.3 12.5 15.0 17.9 5.7 5.9 6.0 5.9 5.7
35 90 9.7 11.9 14.3 17.2 6.9 7.2 7.3 7.4
Cool gas

40 100 10.2 12.4 14.9 7.7 8.0 8.2


40 110 12.80 15.4 8.6 8.9
10 45 18.4 22.4 27.0 32.2 4.7 4.5 4.2 3.7
Condensing

15 50 16.6 20.3 24.5 29.4 34.9 5.3 5.2 4.9 4.6 4.0
20 57 14.8 18.2 22.0 26.3 31.3 5.8 5.8 5.7 5.4 5.0
25 64 12.8 15.8 19.2 23.0 27.4 6.4 6.5 6.5 6.3 6.0
4MTL-09
30 75 10.1 12.6 15.3 18.4 21.9 6.9 7.1 7.2 7.2 7.0
35 90 11.9 14.6 17.7 21.1 8.4 8.7 8.9 9.0
Cool gas

40 100 12.7 15.3 18.4 9.4 9.8 10.0


40 110 15.9 19.0 10.6 10.9
10 45 24.1 29.1 35.0 41.7 6.1 5.9 5.5 4.9
Condensing

15 50 21.8 26.4 31.9 38.1 45.0 6.8 6.8 6.5 6.0 5.3
20 57 19.5 23.7 28.6 34.3 40.6 7.6 7.6 7.4 7.0 6.5
25 64 16.9 20.6 25.0 30.0 35.6 8.3 8.4 8.4 8.2 7.7
4MTL-12
30 75 13.5 16.4 20.0 24.1 28.6 9.0 9.3 9.4 9.3 9.0
35 90 12.8 15.7 19.3 23.3 27.9 10.2 10.9 11.3 11.6 11.6
Cool gas

40 100 13.6 16.8 20.4 24.4 11.5 12.2 12.6 12.8


40 110 17.4 21.2 25.5 12.8 13.5 13.9
10 45 31.2 37.9 45.6 54.4 7.9 7.6 7.1 6.3
Condensing

15 50 28.3 34.5 41.6 49.7 58.7 8.8 8.7 8.4 7.8 6.9
20 57 25.3 30.9 37.4 44.8 53.0 9.7 9.7 9.6 9.2 8.6
25 64 22.0 26.9 32.7 39.3 46.6 10.5 10.8 10.8 10.7 10.2
4MTL-15
30 75 17.5 21.5 26.2 31.6 37.5 11.4 11.8 12.0 12.1 11.8
35 90 16.5 20.5 25.2 30.5 36.5 13.1 13.8 14.4 14.8 15.0
Cool gas

40 100 17.7 21.8 26.6 31.8 14.8 15.5 16.1 16.4


40 110 22.5 27.5 33.1 16.6 17.3 17.9
10 45 45.6 54.9 65.9 78.3 11.4 11.0 10.4 9.3
Condensing

15 50 41.5 50.2 60.3 71.7 84.4 12.6 12.5 12.1 11.4 10.2
20 57 37.2 45.1 54.3 64.7 76.3 13.9 14.0 13.9 13.4 12.5
25 64 32.4 39.4 47.6 56.9 67.2 15.2 15.5 15.6 15.4 14.8
4MTL-30
30 75 25.9 31.6 38.3 45.8 54.2 16.4 16.9 17.3 17.4 17.1
35 90 24.7 30.3 37.0 44.6 53.1 18.8 19.8 20.6 21.2 21.5
Cool gas

40 100 26.3 32.2 39.0 46.5 21.2 22.2 23.0 23.6


40 110 33.4 40.5 48.5 23.8 24.8 25.6
Conditions: Suction Superheat 10K / Subcooling 0K

GPC-EN-2024 REFRIGERATION APPLICATIONS 108


Capacity data (continued)
Cooling Capacity (kW) Power Input (kW)

Pressure (bar)
Evaporating Temperature (°C) Evaporating Temperature (°C)

Temperature
-20 -15 -10 -5 0 -20 -15 -10 -5 0

(°C)
Model
Equivalent Evaporation Pressure (bar) Equivalent Evaporation Pressure (bar)
19.7 22.9 26.5 30.5 34.9 19.7 22.9 26.5 30.5 34.9
10 45 55.8 68.0 82.0 97.9 14.1 13.4 12.5 11.0
Condensing

15 50 50.5 61.7 74.6 89.3 106.0 15.8 15.4 14.8 13.6 12.0
20 57 45.1 55.2 66.9 80.2 95.3 17.4 17.4 17.0 16.2 15.0
25 64 39.2 48.2 58.5 70.3 83.6 18.9 19.2 19.2 18.8 17.9
4MTL-35
30 75 31.2 38.6 46.9 56.5 67.2 20.3 21.0 21.3 21.2 20.7
35 90 29.7 37.0 45.3 54.8 65.5 22.7 24.2 25.3 26.0 26.3
Cool gas

40 100 32.0 39.4 47.8 57.2 25.6 27.1 28.3 28.9


40 110 40.6 49.5 59.5 28.9 30.4 31.5
10 45 68.7 82.7 99.1 118.0 16.4 15.8 14.6 12.9
Condensing

15 50 62.4 75.3 90.4 107.5 127.5 18.4 18.2 17.4 16.0 14.1
20 57 55.8 67.6 81.2 96.9 114.5 20.4 20.5 20.1 19.1 17.6
25 64 48.6 59.0 71.1 84.9 100.5 22.3 22.8 22.7 22.2 21.1
4MTL-40
30 75 38.7 47.2 57.1 68.2 80.8 24.0 24.9 25.3 25.2 24.6
35 90 36.7 45.00 54.4 64.9 76.6 27.0 28.6 29.7 30.2 30.1
Cool gas

40 100 39.5 48.2 58.0 69.0 30.7 32.5 33.8 34.5


40 110 50.2 60.6 72.1 34.6 36.3 37.6
10 45 81.6 98.3 117.5 140.0 20.0 19.3 18.1 16.2
Condensing

15 50 74.2 89.7 107.5 128.0 151.5 22.3 22.1 21.2 19.8 17.8
20 57 66.4 80.6 96.9 115.5 136.5 24.7 24.9 24.4 23.4 21.8
25 64 57.9 70.5 84.9 101.5 120.0 26.9 27.6 27.6 27.1 25.9
4MTL-50
30 75 46.2 56.5 68.2 81.5 96.3 29.1 30.2 30.7 30.7 30.0
35 90 43.9 53.9 65.0 77.4 91.2 32.7 34.7 36.0 36.6 36.6
Cool gas

40 100 47.3 57.5 68.9 81.6 37.2 39.3 40.9 41.8


40 110 59.6 71.5 84.8 41.8 43.8 45.3
Conditions: Suction Superheat 10K / Subcooling 0K
Preliminary Data

109 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland Stream compressors with Compressor Electronics for
R744-subcritical applications requiring high standstill pressures (90bar)

Stream series of 4 cylinder CO2 compressors is the ideal


solution for R744 low temperature cascade and booster
systems requiring high standstill pressure of up to 90 bar
suction. The use of transcritical compressors in medium /
transcritical side as well as on the low temperature / subcritical
side ensures that in case of power outage, the refrigeration
system features full resilience and no operation disruption.

Stream is characterized by a design pressure of 135 bar.


Refrigerant flow and heat transfer have been optimized for
best performance. All compressors are equipped with a
Copeland Compressor Electronics Technology and offer the
possibility to diagnose system-related problems faster or even
before they occur. Copeland Stream compressor for low
temperature applications with R744

Stream compressor line-up

R744

Cooling Capacity (kW)


0 5 10 15 20

Conditions: EN12900 R744: Evaporating -35°C, condensing -5°C, superheat 10K, subcooling 0K

Features and benefits Operating envelope R744


30
Stream provides for flexibility in pack design and operation:
• Compressor max. pressures (suction/discharge):
90 bar / 135 bar 20
Condensing Temperature °C

• Compact dimensions
• Integrated low pressure relief valve 10
• Discharge temperature protection
• Service valve 360° rotation for ease of piping design
0
• 2 sight glasses for mounting of oil management control
and visual inspection
• One oil port for oil equalization in parallel system -10
• Oil splasher system ensuring lubrication at constant and
variable speed -20

Designed for durability and performance in R744 applications:


-30
• Low sound, low vibration and large discharge chamber to
-55 -50 -45 -40 -35 -30 -25 -20 -15 -10
eliminate pulsation
Evaporating Temperature °C
• Optimized motor selection for low temperature running
conditions 10K Superheat 0°C Suction Gas Return
• Burst pressures in excess of safety factor 3
• Cylinder head and discharge plenum design minimizing
heat transfer to suction side
• Stepless capacity modulation via inverter from 25 to 70 Hz
• Copeland compressor electronics technology for
advanced protection, diagnostics, communication
• Individual compressor power consumption monitoring

GPC-EN-2024 REFRIGERATION APPLICATIONS 110


Technical overview

@1 m - dB(A)***
Net Weight (kg)

Sound Pressure
Oil Quantity (l)
Displacement

Capacity (kw)
Nominal hp
Maximum
Motor Version/ Locked Rotor

(m3/h)
Length/Width/ Operating

COP
Models Code Current (A)
Height (mm) Current (A)

3 Ph** 3 Ph** 3 Ph**


4MSL-03 3.0 4.6 7.1 3.3 1.3 630/425/410 120 EWL 7.0 50 76
4MSL-04 4.0 6.2 9.7 3.5 1.3 630/425/410 120 EWL 8.8 50 76
4MSL-06 6.0 7.4 12.2 3.7 1.3 630/425/410 120 EWL 10.5 62 76
4MSL-08 8.0 9.5 15.9 3.6 1.8 697/444/423 170 AWM 13.9 87 76
4MSL-12 12.0 12.5 21.0 3.7 1.8 697/445/422 170 AWM 18.7 145 76
4MSL-15 15.0 18.0 31.0 3.8 1.8 697/445/422 170 AWM 25.7 156 76
Conditions EN12900 - LT: Evaporating -35°C , Condensing -5°C, Suction Superheat 10K, 0K Subcooling
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

Capacity data
Condensing Temperature -10°C
Cooling Capacity (kW) Power Input (kW)
R744 R744
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -40 -35 -30 Model -45 -40 -35 -30
4MSL-03 4.6* 6.1* 7.8* 9.9* 4MSL-03 1.9* 1.9* 1.9* 1.8*
4MSL-04 6.2* 8.2* 10.6* 13.4* 4MSL-04 2.4* 2.5* 2.5* 2.3*
4MSL-06 7.6* 10.1* 13.0* 16.5* 4MSL-06 2.8* 2.9* 2.9* 2.8*
4MSL-08 10.3* 13.4* 17.1* 21.5* 4MSL-08 3.8* 4.0* 3.9* 3.7*
4MSL-12 13.8* 17.8* 22.7* 28.4* 4MSL-12 4.9* 5.0* 5.0* 4.8*
4MSL-15 20.3* 26.3* 33.4* 41.5* 4MSL-15 7.0* 7.2* 7.2* 7.0*
Conditions: Suction Gas Return 20°C / Subcooling 0K
*Conditions: Suction Superheat 10K, Subcooling 0K

111 GPC-EN-2024 REFRIGERATION APPLICATIONS


Refrigeration units

Refrigeration units

Copeland offers the broadest and most reliable refrigeration unit product line-up. Leveraging the latest compressor technology,

each platform provides you the option to select the refrigerant, capacity and application temperature combinations that meet your

requirements. A huge variety of indoor and outdoor refrigeration units offer the right solution for applications in food retail and food

service, commercial and industrial refrigeration.

Copeland scroll outdoor refrigeration units are designed and fully equipped for a quick and easy installation and ideal to integrate into
urban environments. The latest scroll technology is combined with high-quality components and covered by a weatherproof housing in

a unique design.

The Copeland ZX refrigeration unit series offers the highest energy efficiency available in a standard unit to lower operators’ utility bills.

Ranging in size from 1.2 to 7.5 hp, the ZX units are perfectly suited for typical food service and retail applications. The key benefits of

compactness, silence and efficiency in the standard models will be enhanced by the capability of continuous capacity modulation of

the ZX digital models. This makes ZX digital refrigeration units the perfect fit for applications with wide load variations.

GPC-EN-2024 REFRIGERATION APPLICATIONS 112


Copeland scroll indoor refrigeration units are equipped with the latest refrigeration scroll compressors and constitute the widest range

of their kind. The modular line concept offers base units which can be adapted to the target application by various options including

weather housings and fan speed controls.

Copeland scroll digital receiver units HLR are an innovative offering for food service and retail businesses. Their compact design and the

power of digital scroll continuous capacity modulation enable optimized environmental integration with highest system efficiency.

Semi-hermetic refrigeration units: robust, reliable and efficient air-cooled refrigeration unitplatforms featuring semi-hermetic reciprocating

compressor technology are for use in high-medium- and low-temperature applications. Copeland has expanded its semi-hermetic

product range by the innovative Stream indoor refrigeration units which complete a product range from 0.8 - 40 hp with dedicated

refrigerant approvals for R407A/F, R448A/ R449A, R404A, R134a, R450A and R513A.

113 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland large outdoor refrigeration units

Copeland air-cooled outdoor refrigeration units for medium-


temperature and low-temperature applications.

Copeland has developed this series of refrigeration units


especially for outdoor use. They feature the latest technology in
an assembly of high quality components which are adjusted for
efficient and reliable operation.

The line-up offers state-of-the-art technology and models


featuring stepless capacity control, vapor injection and fan speed
control. This makes it the first choice for target applications in food
retail and food service:

- Proximity and convenience stores


- Mini markets and supermarkets Copeland outdoor refrigeration unit
- Bars, restaurants and kitchens with scroll compressors
- Beer cellars and beverage coolers

OL/OM line-up

LT models

Digital MT models

Digital LT models

Capacity (kW)
R448A/R449A, EN13215 0 10 20 30 40

Features and benefits Maximum allowable pressure (PS)

• Standard equipment: scroll compressor(s), crankcase • Low Side PS 22.5 bar (g)
heater(s), condenser with thermally protected fan(s), fan • High Side PS 28 bar (g)
speed control, HP and LP switch, and EC fan(s)
• Suitable for multiple refrigerants: R407A/F, R448A/ R449A,
R404A, R134a, R450A and R513A
• Wide range of quality accessories
• Excellent efficiency
• Filter drier, liquid sight glass and solenoid valve in liquid line
• Minimize capital investment
• Designed to the quality requirements of the retail sector
• Ready for heat recovery
• Liquid level control
• Remote monitoring capability (Modbus)

GPC-EN-2024 REFRIGERATION APPLICATIONS 114


Technical overview

Displacement (m3/h)

Net Weight (kg)


Total Fan Motor

Diameter (inch)

Diameter (inch)
Number of fans

Pressure
Maximum Oper- Locked

Sound
Suction Line
Capacity (l)
Motor

Liquid Line
Power (W)
ating Rotor

Receiver
Width/Depth/ Version/ Code
Models Current (A) Current (A)
Height (mm)

@10m -
3 Ph** 3 Ph** 3 Ph**
d(BA)***
Digital Medium Temperature Models
OMTE-76D 28.7 20 1 480 1 3/8 5/8 1574/920/1135 345 TFD 11+13 64+66 45
OMTE-90D 34.1 20 1 480 1 /8 3
5/8 1574/920/1135 348 TFD 12+13 2x74 45
OMTE-152D 57.6 30 2 826 1 5/8 7/8 2300/920/1135 508 TFD 24+20 2x118 47
Low Temperature Models
OLE-49 42.4 20 1 410 1 3/8 1/2 1574/920/1135 318 TFD 30.0 139 46
Low Temperature Digital Models
OLTE-82D 70.7 31 2 684 1 5/8 7/8 2300/920/1135 511 TFD 2x29 2x118 47
Conditions EN13215: R448A/R449A, Evaporating Temperature MT -10°C/ LT - 35°C, Ambient Temperature 32°C, Suction Gas Return 20°C
** 3 Ph: 380-420V/ 50Hz
*** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R407A Evaporating Temperature (°C) R407A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Digital Medium Temperature Models
OMTE-76D 16.60 19.90 27.10 OMTE-76D 8.16 8.63 9.73
OMTE-90D 11.70* 18.20 21.60 29.20 OMTE-90D 8.86* 9.83 10.35 11.55
OMTE-152D 21.40 32.90 39.60 53.90 OMTE-152D 15.50 16.95 18.20 20.90

Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R407F Evaporating Temperature (°C) R407F Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Digital Medium Temperature Models
OMTE-76D 10.60* 16.10* 19.60 26.80 OMTE-76D 7.46* 8.47* 9.06 10.30
OMTE-90D 18.20* 22.40 OMTE-90D 10.30* 11.15
OMTE-152D 34.40 41.40 56.30 OMTE-152D 18.10 19.55 22.60
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

115 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R448A / R448A /
Evaporating Temperature (°C) Evaporating Temperature (°C)
R449A R449A
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Digital Medium Temperature Models
OMTE-76D 11.10 16.65 19.85 27.10 OMTE-76D 7.22 8.18 8.72 10.00
OMTE-90D 12.10* 18.95 22.50 30.30 OMTE-90D 8.31* 9.62 10.30 11.95
OMTE-152D 33.90 40.50 55.10 OMTE-152D 16.80 17.75 20.30
Low Temperature Models
OLE-49 8.99 11.25 16.70 23.30 27.00 OLE-49 8.29 8.68 10.05 12.20 13.60
Digital Low Temperature Models
OLTE-82D 13.50 17.00 25.60 35.90 OLTE-82D 13.75 14.90 17.85 21.70
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary Data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R513A Evaporating Temperature (°C) R513A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Digital Medium Temperature Models
OMTE-76D 7.68 12.00 14.75 21.50 OMTE-76D 4.40 4.63 4.75 5.03
OMTE-90D 9.04 14.15 17.35 25.20 OMTE-90D 5.09 5.39 5.56 6.01
OMTE-152D 14.90 23.10 28.10 39.90 OMTE-152D 9.65 10.50 10.90 11.75
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary Data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R404A Evaporating Temperature (°C) R404A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Digital Medium Temperature Models
OMTE-76D 12.30 17.30 20.20 26.60 OMTE-76D 7.70 8.44 8.84 9.65
OMTE-90D 14.20 19.80 23.00 29.90 OMTE-90D 9.18 10.15 10.70 11.85
OMTE-152D 25.30 36.00 42.00 54.80 OMTE-152D 16.50 17.90 18.65 20.30
Low Temperature Models
OLE-49 10.20 12.50 18.05 24.80 28.70 OLE-49 8.00 8.54 9.93 11.70 12.70
Digital Low Temperature Models
OLTE-82D 17.15 21.00 30.00 41.00 47.20 OLTE-82D 13.25 14.35 16.70 19.40 20.90
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

GPC-EN-2024 REFRIGERATION APPLICATIONS 116


Capacity data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R407C Evaporating Temperature (°C) R407C Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Digital Medium Temperature Models
OMTE-76D 9.39* 14.95 18.00 25.20 OMTE-76D 6.73* 7.40 7.79 8.73
OMTE-90D 17.45 21.00 29.10 OMTE-90D 9.08 9.59 10.85
OMTE-152D 31.60 38.00 52.80 OMTE-152D 15.95 16.80 18.95
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R134a Evaporating Temperature (°C) R134a Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Digital Medium Temperature Models
OMTE-76D 6.87 10.85 13.20 18.75 OMTE-76D 4.44 4.90 5.13 5.67
OMTE-90D 7.79* 12.60 15.35 21.90 OMTE-90D 5.11* 5.71 6.01 6.71
OMTE-152D 14.05 21.70 26.50 37.90 OMTE-152D 9.78 10.20 10.65 11.60
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary Data

117 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland R744 Stream refrigeration units
With this range of outdoor refrigeration units, Copeland offers a solution which
responds to the increasing demand for future proof refrigeration technology.

These models are designed for operation with the natural refrigerant CO2
which has a very low global warming potential (GWP) of only 1.

The range features the latest technology like Stream series compressors
which are characterized by their silent and reliable operation. The integrated
frequency inverter controls the compressor speed exactly to the capacity
demand of the application. EC-fans remove the heat from the gas cooler in the
most efficient and silent way.

The state of the art electronic contoller allows for precise adjustment and
control of all relevant parameters and comprises numerous electronic
protection functions for highly reliable operation.

The refrigeration units are future-proof choice for various target applications: Copeland R744 Stream refrigeration units
• Convenience stores
• Forecourt sites
• Cold rooms
• Fast food stores, bars and restaurants

R744 Stream refrigeration unit line-up


OME-4MTL-05
OME-4MTL-07
OME-4MTL-09
OME-4MTL-12
Capacity (kW)
0 5 10 15 20

Technical overview

Sound Pressure @10m


Liquid Line Diameter
Receiver Capacity (l)

Motor Version/

Locked Rotor
Current (A)

Current (A)
Net Weight (kg)

Operating
Maximum
Diameter (inch)
Capacity (kW)
Displacement

Suction Line

Code

- d(BA)**
(m3/h)

(inch)

Width/Depth/
Model
Height (mm)

3 Ph* 3 Ph* 3 Ph*

OME-4MTL-05 4.6 8.69 20 3⁄4 5⁄8 1574/920/1135 450 EWL 13 81 43

OME-4MTL-07 6.2 11.80 20 3⁄4 5⁄8 1574/920/1135 450 EWL 18 81 44

OME-4MTL-09 7.4 14.25 25 7⁄8 5⁄8 1574/920/1135 462 EWL 21 94 45

OME-4MTL-12 9.5 18.80 25 7⁄8 5⁄8 1574/920/1135 473 AWM 27 145 45


Conditions EN13215: R744, evaporating temperature -10°C, ambient temperature 32°C, suction superheat 10 K
* @ 10m: sound pressure level at 10m distance from the compressor, free field condition
**90 bar liquid line.
For detailed capacity data please refer to Copeland Select software

Features and benefits


• Future-proof solution with natural GWP 1 refrigerant, not • Modbus communication and monitoring functionality
impacted by F-Gas legislation • LCD display to show the operation status
• Low carbon footprint • OilWatch maintains correct system oil level
• Silent operation due to special attenuation on panels and • Controller prepared for heat recovery
sound optimized EC fans • Easy access for time saving service
• High energy efficiency through inverter controlled • Built and tested in advanced industrial processes
compressor and EC fans • Individual compressor power consumption monitoring
• Space saving design
• Time saving comissioning by pre-set parameters
• High reliability with electronic protection against incorrect Design pressure:
voltage, phase, current and discharge temperature • 90 bar in receiver and liquid line
• State of the art controller for precise system control • 120 bar on high-pressure side

GPC-EN-2024 REFRIGERATION APPLICATIONS 118


119 GPC-EN-2024 REFRIGERATION APPLICATIONS
Copeland ZX outdoor refrigeration units for A2L refrigerants
Copeland ZX outdoor refrigeration units combine efficient
Copeland scroll technology with compact cabinet design and noise
attenuation features, that enable legal compliance for applications
with A2L refrigerants. The new range is specifically designed to
cater for a wide range of refrigeration applications which request a
low GWP and future-proof solution.

Copeland ZX units feature the most complete and unique


equipment. The modified design, the innovative control logic and
a selection of dedicated components enable legal compliance
for applications with A2L refrigerants. The advanced electronic
controller enables precise parameter control and displays the
system status. Electronic protection functions, oil separator and
suction accumulator guarantee optimum system safety. The range
is completed by models with stepless digital capacity modulation
which are well established in applications with multiple evaporators A2L
and precise temperature control. approved

This series of Copeland of outdoor refrigeration units is specifically


designed to cater for a wide range of refrigeration applications
Copeland ZX outdoor refrigeration units
which request a low GWP and future-proof solution:
for A2L refrigerants
• Convenience stores
• Cold rooms
• Fast food chains and restaurants
• Beverage coolers

ZX refrigeration unit line-up for A2L refrigerants

ZXMY for MT

ZXLY for LT

ZXDY digital for MT

Capacity (kW)
R454C, EN13215 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Features and benefits


• Standard equipment: Copeland scroll compressor,
crankcase heater, electronic controller, liquid receiver,
service valves, filter drier & sight glass, external main
power switch, fan speed control​
• Oil separator (ZX digital) and suction accumulator (ZX
digital & low temperature models)​
• Multiple refrigerant approvals incl. R404A, R407A,
R407F, R448A, R449A, R134a, R450A, R513A, R454A,
R454C, R455A, R1234yf​
• ZX digital models allow for 10% to 100% continuous
capacity modulation​
• Electronic unit controller with intelligent protection
and diagnostics capabilities​
• Energy and operation cost saving due to excellent
energy efficiency​
• Quiet operation due to new fans with improved
sound level, Copeland scroll compressor, and fan
speed control​
• Space saving due to compact dimensions​
• Easy and quick installation

GPC-EN-2024 REFRIGERATION APPLICATIONS 120


Technical overview

Displacement (m3/h)

Pressure
Number of Fans

Net Weight (kg)


Total Fan Motor

Diameter (inch)

Diameter (inch)
Maximum Locked

Sound
Suction Line
Motor

Capacity (l)

Liquid Line
Power (W)
Operating Rotor

Receiver
Width/Depth/ Version/ Code
Models Current (A) Current (A)
Height (mm)

3 Ph* 3 Ph* 3 Ph* @10m - d(BA)**

Medium Temperature Models

ZXMY-020E 5.8 4.1 1 121 3/4 1/2 446/1035/840 73 TFM 4 26 37

ZXMY-030E 8.0 4.1 1 121 3/4 1/2 446/1035/840 80 TFM 5 32 38

ZXMY-040E 11.4 4.1 1 121 7/8 1/2 446/1035/840 86 TFM 7 50 38

ZXMY-050E 14.3 5.9 2 242 7/8 1/2 446/1035/1244 112 TFM 10 64 41

ZXMY-060E 16.7 5.9 2 242 7/8 1/2 446/1035/1244 114 TFM 12 74 41

ZXMY-075E 21.4 5.9 2 242 7/8 1/2 446/1035/1244 116 TFM 16 102 41

Digital Medium Temperature Models

ZXDY-030E 8.8 4.1 1 121 3/4 1/2 446/1035/840 85 TFM 7 40 39

ZXDY-040E 11.4 5.9 2 242 7/8 1/2 446/1035/1244 106 TFM 10 48 42

ZXDY-050E 14.4 5.9 2 242 7/8 1/2 446/1035/1244 118 TFM 11 64 42

ZXDY-060E 17.1 5.9 2 242 7/8 1/2 446/1035/1244 120 TFM 12 74 43

ZXDY-075E 21.4 5.9 2 242 7/8 1/2 446/1035/1244 122 TFM 16 102 43

Low Temperature Models

ZXLY-020E 5.9 3.9 1 121 3/4 1/2 446/1035/840 78 TFD 5 24 37

ZXLY-030E 8.0 3.9 1 121 3/4 1/2 446/1035/840 81 TFD 6 36 37

ZXLY-040E 11.8 3.9 1 121 7/8 1/2 446/1035/840 93 TFD 8 46 38

ZXLY-050E 14.4 5.9 2 242 7/8 1/2 446/1035/1244 110 TFD 10 58 41

ZXLY-060E 17.1 5.9 2 242 7/8 1/2 446/1035/1244 114 TFD 13 67 41

ZXLY-075E 21.4 5.9 2 242 7/8 1/2 446/1035/1244 120 TFD 16 92 42


* 3ph: 380-420V/ 50Hz
** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

121 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R454A R454A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXMY-020E 2.47 3.60 4.28 5.83 ZXMY-020E 1.44 1.62 1.72 1.96
ZXMY-030E 3.42 4.96 5.87 7.99 ZXMY-030E 1.96 2.17 2.30 2.63
ZXMY-040E 4.82 6.94 8.19 11.05 ZXMY-040E 2.81 3.16 3.35 3.80
ZXMY-050E 6.11 8.86 10.50 14.20 ZXMY-050E 3.39 3.85 4.11 4.69
ZXMY-060E 7.16 10.35 12.20 16.40 ZXMY-060E 4.00 4.58 4.90 5.65
ZXMY-075E 8.92 12.80 15.00 20.00 ZXMY-075E 5.16 5.96 6.41 7.43
Digital Medium Temperature Models
ZXDY-030E 3.70 5.31 6.26 8.41 ZXDY-030E 2.22 2.47 2.64 3.05
ZXDY-040E 4.93 7.17 8.52 11.70 ZXDY-040E 2.83 3.13 3.29 3.66
ZXDY-050E 6.14 8.90 10.50 14.25 ZXDY-050E 3.42 3.89 4.15 4.75
ZXDY-060E 7.28 10.50 12.40 16.60 ZXDY-060E 4.10 4.70 5.04 5.83
ZXDY-075E 8.98 12.90 15.20 20.40 ZXDY-075E 5.11 5.88 6.31 7.30
Low Temperature Models
ZXLY-020E 1.33 1.63 2.34 3.23 3.73 4.85 ZXLY-020E 1.27 1.39 1.63 1.86 1.96 2.11
ZXLY-030E 1.77 2.15 3.07 4.18 4.79 6.12 ZXLY-030E 1.73 1.92 2.32 2.79 3.04 3.60
ZXLY-040E 2.39 2.88 3.95 5.05 5.56 6.30 ZXLY-040E 3.01 3.39 4.35 5.76 6.71 9.33
ZXLY-050E 3.20 3.89 5.54 7.51 8.58 10.84 ZXLY-050E 2.99 3.30 4.03 4.99 5.59 7.09
ZXLY-060E 3.76 4.55 6.42 8.61 9.78 12.15 ZXLY-060E 3.57 3.95 4.89 6.18 6.99 9.10
ZXLY-075E 4.73 5.72 8.05 10.76 12.21 15.17 ZXLY-075E 4.27 4.71 5.81 7.27 8.19 10.52
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary Data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R454C R454C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXMY-020E 2.09 3.05 3.62 4.95 ZXMY-020E 1.24 1.39 1.47 1.66
ZXMY-030E 2.91 4.23 5.01 6.83 ZXMY-030E 1.68 1.84 1.94 2.20
ZXMY-040E 4.12 5.94 7.03 9.53 ZXMY-040E 2.38 2.64 2.80 3.15
ZXMY-050E 5.20 7.53 8.90 12.10 ZXMY-050E 2.90 3.26 3.46 3.93
ZXMY-060E 6.08 8.77 10.35 13.95 ZXMY-060E 3.39 3.85 4.10 4.70
ZXMY-075E 7.60 10.90 12.80 17.10 ZXMY-075E 4.38 4.99 5.34 6.17
Digital Medium Temperature Models
ZXDY-030E 3.16 4.55 5.37 7.24 ZXDY-030E 1.88 2.08 2.20 2.53
ZXDY-040E 4.19 6.10 7.25 9.94 ZXDY-040E 2.43 2.67 2.80 3.11
ZXDY-050E 5.23 7.56 8.94 12.10 ZXDY-050E 2.92 3.29 3.50 3.98
ZXDY-060E 6.19 8.92 10.50 14.15 ZXDY-060E 3.47 3.94 4.21 4.84
ZXDY-075E 7.66 11.00 13.00 17.45 ZXDY-075E 4.33 4.92 5.25 6.04
Low Temperature Models
ZXLY-020E 1.05 1.28 1.83 2.50 2.87 3.65 ZXLY-020E 0.98 1.10 1.39 1.75 1.96 2.48
ZXLY-030E 1.41 1.72 2.47 3.36 3.83 4.82 ZXLY-030E 1.36 1.53 1.95 2.50 2.85 3.73
ZXLY-040E 2.01 2.48 3.55 4.74 5.34 6.39 ZXLY-040E 1.99 2.27 2.98 4.03 4.75 6.89
ZXLY-050E 2.59 3.18 4.61 6.36 7.33 9.40 ZXLY-050E 2.23 2.46 3.02 3.78 4.26 5.51
ZXLY-060E 3.04 3.72 5.33 7.25 8.29 10.43 ZXLY-060E 2.68 2.96 3.67 4.70 5.38 7.23
ZXLY-075E 3.78 4.57 6.46 8.67 9.87 12.34 ZXLY-075E 3.32 3.66 4.49 5.60 6.29 8.02
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 122


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R455A R455A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXMY-020E 2.14 3.10 3.67 4.98 ZXMY-020E 1.35 1.54 1.65 1.87
ZXMY-030E 3.01 4.33 5.11 6.89 ZXMY-030E 1.83 2.05 2.19 2.52
ZXMY-040E 4.26 6.06 7.12 9.58 ZXMY-040E 2.60 2.96 3.15 3.60
ZXMY-050E 5.37 7.69 9.06 12.20 ZXMY-050E 3.16 3.63 3.90 4.48
ZXMY-060E 6.29 8.99 10.55 14.20 ZXMY-060E 3.69 4.29 4.61 5.36
ZXMY-075E 7.87 11.15 13.10 17.40 ZXMY-075E 4.77 5.57 6.01 7.00
Digital Medium Temperature Models
ZXDY-030E 3.26 4.67 5.48 7.31 ZXDY-030E 2.05 2.32 2.48 2.88
ZXDY-040E 4.33 6.24 7.32 9.95 ZXDY-040E 2.65 2.94 3.16 3.56
ZXDY-050E 5.40 7.73 9.10 12.25 ZXDY-050E 3.18 3.67 3.94 4.53
ZXDY-060E 6.40 9.15 10.75 14.40 ZXDY-060E 3.78 4.39 4.74 5.51
ZXDY-075E 7.93 11.30 13.25 17.70 ZXDY-075E 4.72 5.49 5.91 6.86
Low Temperature Models
ZXLY-020E 1.17 1.44 2.11 2.92 3.38 4.35 ZXLY-020E 1.10 1.23 1.56 2.05 2.39 3.36
ZXLY-030E 1.62 2.01 2.99 4.23 4.95 6.56 ZXLY-030E 1.33 1.45 1.74 2.11 2.34 2.94
ZXLY-040E 2.14 2.61 3.71 4.97 5.65 7.04 ZXLY-040E 2.20 2.45 3.00 3.67 4.05 4.91
ZXLY-050E 2.77 3.41 4.95 6.79 7.80 9.92 ZXLY-050E 2.59 2.87 3.55 4.46 5.04 6.54
ZXLY-060E 3.24 3.97 5.70 7.73 8.83 11.09 ZXLY-060E 3.17 3.52 4.37 5.49 6.19 7.96
ZXLY-075E 3.95 4.82 6.84 9.15 10.37 12.84 ZXLY-075E 4.10 4.57 5.69 7.09 7.92 9.92
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary Data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R1234yf R1234yf
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXMY-020E 1.33* 2.23 2.69 3.77 ZXMY-020E 0.87* 0.96 1.00 1.11
ZXMY-030E 1.86* 3.11 3.73 5.23 ZXMY-030E 1.14* 1.25 1.32 1.48
ZXMY-040E 2.62* 4.35 5.20 7.23 ZXMY-040E 1.61* 1.78 1.88 2.08
ZXMY-050E 3.34* 5.54 6.63 9.22 ZXMY-050E 1.99* 2.21 2.33 2.61
ZXMY-060E 3.86* 6.42 7.67 10.60 ZXMY-060E 2.34* 2.60 2.74 3.07
ZXMY-075E 4.89* 8.06 9.59 13.15 ZXMY-075E 2.95* 3.31 3.51 3.99
Digital Medium Temperature Models
ZXDY-030E 2.02* 3.37 4.03 5.62 ZXDY-030E 1.25* 1.39 1.47 1.66
ZXDY-040E 2.69* 4.49 5.40 7.62 ZXDY-040E 1.69* 1.84 1.92 2.08
ZXDY-050E 3.37* 5.60 6.70 9.34 ZXDY-050E 2.01* 2.22 2.34 2.61
ZXDY-060E 3.95* 6.58 7.86 10.90 ZXDY-060E 2.38* 2.64 2.78 3.12
ZXDY-075E 4.94* 8.16 9.74 13.45 ZXDY-075E 2.92* 3.26 3.45 3.91
Conditions: EN13215: Suction Superheat 10K For detailed capacity data please refer to Copeland Select software
Preliminary Data

123 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland ZX outdoor refrigeration units with scroll compressors

Copeland compact outdoor refrigeration units are for medium-


temperature and low-temperature applications.

With this range of outdoor refrigeration units, Copeland offers a solution


for refrigeration applications with space and noise constraints which
responds to the increasing demand for energy-efficient refrigeration
solutions units.

Copeland ZX outdoor refrigeration units feature the most complete and


unique equipment. Their advanced electronic controller enables precise
parameter control and displays the system status. Vapor injection and
liquid injection technology significantly increase system efficiency and
operation map. Electronic protection functions, oil separator and suction
accumulator guarantee optimum system safety.

Lowest life cycle costs and comprehensive safety features make


Copeland ZX a cost efficient and reliable choice for:
- Convenience stores Copeland ZX outdoor refrigeration units
- Cold rooms with scroll compressors
- Fast food stores, bars and restaurants
- Beverage coolers

Copeland ZX line-up

ZXME for MT
ZXLE for LT
ZXDE digital for MT

Capacity (kW)
R448A/R449A, EN13215 0 5 10 15 20

Features and benefits Maximum allowable pressures (PS)

• Standard equipment: Copeland scroll compressor, crankcase • Low Side PS 22.5 bar (g)
heater, electronic controller, fan(s) with speed control, liquid • High Side PS 28.8 bar (g)
receiver, safety switches, filter drier and sight glass, oil separator
and suction accumulator (LT models only)
• Copeland ZX digital models allow for 10% to 100% continuous
capacity modulation
• Diagnostic capabilities protect the unit from over-current,
phase loss and phase imbalance
• LED display shows real time system status
• Precise electronic suction pressure control
• Energy and operation cost saving due to excellent
energy efficiency
• Noise attenuation due to low speed fan motors with sickle
blades, fan speed control and sound jacket
• High capacity vapor injection technology for LT models
• Space saving due to compact dimensions
• Easy and quick installation
• Multiple refrigerant approvals incl. R407A/F, R448A/R449A,
R404A, R134a, R450A and R513A

GPC-EN-2024 REFRIGERATION APPLICATIONS 124


Technical overview

Diameter (inch)

Net Weight (kg)


Total Fan Motor

Diameter (inch)
Number of fans
Displacement
Maximum

Suction Line
Capacity (l)

Liquid Line
Motor Version/ Locked Rotor Sound

Power (W)
Receiver
Operating

(m3/h)
Width/Depth/ Code Current (A) Pressure
Model Current (A)
Height (mm)

@10m -
1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**
d(BA)***
Medium Temperature Models
ZXME-020E 5.9 4.1 1 116 3/4 1/2 446/1035/840 76 PFJ TFD 13 5 58 26 39
ZXME-025E 6.8 4.1 1 116 3/4 1/2 446/1035/840 79 PFJ TFD 12 5 61 38 40
ZXME-030E 8.6 4.1 1 116 3/4 1/2 446/1035/840 79 PFJ TFD 16 7 82 40 40
ZXME-040E 11.4 4.1 1 116 3/4 1/2 446/1035/840 91 PFJ TFD 24 10 114 49 40
ZXME-050E 17.1 5.9 2 246 7/8 1/2 447/1035/1244 108 TFD 13 66 41
ZXME-060E 18.8 5.9 2 246 7/8 1/2 447/1035/1244 112 TFD 13 74 41
ZXME-075E 11.9 5.9 2 246 7/8 1/2 447/1035/1244 118 TFD 14 101 42
Digital Medium Temperature Models
ZXDE-030E 8.3 4.1 1 116 3/4 1/2 446/1035/840 79 TFD 7 40 40
ZXDE-040E 11.4 5.9 2 246 7/8 1/2 447/1035/1244 104 TFD 8 48 40
ZXDE-050E 14.4 5.9 2 246 7/8 1/2 447/1035/1244 108 TFD 11 64 41
ZXDE-060E 17.1 5.9 2 246 7/8 1/2 447/1035/1244 112 TFD 11 74 41
ZXDE-075E 18.8 5.9 2 246 7/8 1/2 447/1035/1244 118 TFD 14 100 42
Low Temperature Models
ZXLE-020E 6.1 4.1 1 116 3/4 1/2 446/1035/840 79 PFJ TFD 14 6 57 39 39
ZXLE-025E 7.1 4.1 1 116 3/4 1/2 446/1035/840 79 PFJ 16 74 39
ZXLE-030E 8.0 4.1 1 116 3/4 1/2 446/1035/840 81 PFJ TFD 18 7 82 36 40
ZXLE-040E 12.7 4.1 1 116 7/8 1/2 446/1035/840 93 TFD 9 52 40
ZXLE-050E 14.4 5.9 2 246 7/8 1/2 447/1035/1244 106 TFD 12 52 41
ZXLE-060E 17.1 5.9 2 246 7/8 1/2 447/1035/1244 116 TFD 14 74 41
ZXLE-075E 18.8 5.9 2 246 7/8 1/2 447/1035/1244 121 TFD 15 101 41
* 1ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

125 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R407A Evaporating Temperature (°C) R407A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-020E 3.48 4.13 5.60 ZXME-020E 1.67 1.68 1.73
ZXME-025E 2.78 4.02 4.78 6.67 ZXME-025E 1.52 1.66 1.74 1.93
ZXME-030E 4.92 5.93 8.30 ZXME-030E 2.27 2.38 2.57
ZXME-040E 6.26 7.51 10.30 ZXME-040E 3.24 3.39 3.77
ZXME-050E 8.65 10.35 14.40 ZXME-050E 3.73 3.90 4.26
ZXME-060E 9.75 11.75 16.35 ZXME-060E 4.33 4.53 4.99
ZXME-075E 11.25 13.55 18.85 ZXME-075E 4.85 5.07 5.59
Low Temperature Models
ZXLE-020E 1.39 1.82 2.87 4.16 4.90 6.53 ZXLE-020E 1.41 1.48 1.62 1.76 1.84 1.99
ZXLE-025E** 1.63 2.13 3.36 4.91 5.79 7.77 ZXLE-025E** 1.63 1.73 1.89 2.03 2.10 2.24
ZXLE-030E 1.98 2.51 3.81 5.51 6.52 8.88 ZXLE-030E 1.82 1.93 2.11 2.28 2.36 2.55
ZXLE-040E 3.04 3.83 5.67 7.87 9.08 ZXLE-040E 2.76 2.97 3.43 3.95 4.25
ZXLE-050E 3.50 4.42 6.63 9.37 10.90 14.35 ZXLE-050E 3.08 3.27 3.69 4.15 4.41 5.01
ZXLE-060E 4.16 5.18 7.64 10.70 12.45 16.40 ZXLE-060E 4.01 4.29 4.87 5.54 5.93 6.88
ZXLE-075E 4.68 5.86 8.75 12.45 14.65 19.75 ZXLE-075E 4.18 4.43 4.92 5.46 5.77 6.52
Digital Medium Temperature Models
ZXDE-030E 5.08 5.98 7.95 ZXDE-030E 2.13 2.23 2.41
ZXDE-040E 4.72 7.28 8.84 12.50 ZXDE-040E 2.70 2.84 2.93 3.13
ZXDE-050E 5.83 8.65 10.35 14.40 ZXDE-050E 3.47 3.73 3.90 4.26
ZXDE-060E 6.38 9.75 11.75 16.35 ZXDE-060E 4.03 4.33 4.53 4.99
ZXDE-075E 7.35 11.25 13.55 18.85 ZXDE-075E 4.51 4.85 5.07 5.59
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
** Single Phase Only
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 126


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R407F Evaporating Temperature (°C) R407F Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-020E 3.37 4.05 5.68 ZXME-020E 1.62 1.65 1.74
ZXME-025E 2.91 4.20 4.99 6.95 ZXME-025E 1.60 1.75 1.84 2.05
ZXME-030E 4.92 5.93 8.29 ZXME-030E 2.27 2.38 2.57
ZXME-040E 6.52* 7.95 10.85 ZXME-040E 3.33* 3.54 3.99
ZXME-050E 5.68* 8.64 10.35 14.40 ZXME-050E 3.46* 3.73 3.90 4.26
ZXME-060E 6.17* 9.74 11.75 16.35 ZXME-060E 4.01* 4.33 4.53 4.99
ZXME-075E 7.14* 11.20 13.55 18.85 ZXME-075E 4.49* 4.85 5.07 5.59
Low Temperature Models
ZXLE-020E 1.46 1.91 3.01 4.36 5.12 6.81 ZXLE-020E 1.48 1.56 1.71 1.88 1.96 2.14
ZXLE-025E** 1.71 2.23 3.52 5.14 6.06 8.11 ZXLE-025E** 1.72 1.83 2.01 2.16 2.24 2.40
ZXLE-030E 2.08 2.64 4.00 5.76 6.81 9.26 ZXLE-030E 1.93 2.04 2.24 2.43 2.53 2.74
ZXLE-040E 3.19 4.00 5.92 8.17 9.40 ZXLE-040E 2.93 3.16 3.67 4.26 4.59
ZXLE-050E 3.67 4.63 6.94 9.77 11.35 14.90 ZXLE-050E 3.25 3.47 3.92 4.43 4.72 5.39
ZXLE-060E 4.35 5.42 7.97 11.15 12.95 ZXLE-060E 4.24 4.55 5.19 5.94 6.38
ZXLE-075E 4.91 6.14 9.16 13.00 15.30 20.50 ZXLE-075E 4.41 4.68 5.22 5.82 6.17 7.00
Digital Medium Temperature Models
ZXDE-030E 4.94 5.97 8.29 ZXDE-030E 2.27 2.37 2.58
ZXDE-040E 4.67 7.20 8.75 12.40 ZXDE-040E 2.77 2.92 3.01 3.22
ZXDE-050E 5.65 8.64 10.45 14.55 ZXDE-050E 3.65 3.93 4.11 4.51
ZXDE-060E 5.85 8.96 10.85 15.10 ZXDE-060E 3.94 4.22 4.40 4.82
ZXDE-075E 6.65 10.20 12.30 17.20 ZXDE-075E 4.29 4.59 4.78 5.24
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K
For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
** Single Phase Only
Preliminary Data

127 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R448A/ R449A Evaporating Temperature (°C) R448A/ R449A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-020E 2.22 3.42 4.14 5.82 ZXME-020E 1.56 1.58 1.62 1.75
ZXME-025E 2.61 3.83 4.61 6.66 ZXME-025E 1.50 1.64 1.71 1.92
ZXME-030E 3.36 5.05 6.06 8.42 ZXME-030E 2.12 2.28 2.37 2.58
ZXME-040E 4.34 6.58 7.82 10.70 ZXME-040E 3.02 3.29 3.45 3.86
ZXME-050E 5.75 8.77 10.50 14.60 ZXME-050E 3.58 3.79 3.92 4.27
ZXME-060E 6.62 10.05 12.00 16.65 ZXME-060E 4.12 4.41 4.58 5.03
ZXME-075E 7.60 11.55 13.85 19.15 ZXME-075E 4.74 5.07 5.27 5.79
Low Temperature Models
ZXLE-020E 1.45 1.91 3.05 4.46 5.27 7.08 ZXLE-020E 1.38 1.48 1.64 1.77 1.82 1.91
ZXLE-025E** 1.71 2.25 3.59 5.26 6.23 8.38 ZXLE-025E** 1.60 1.72 1.90 2.02 2.07 2.16
ZXLE-030E 2.06 2.59 3.93 5.71 6.80 9.37 ZXLE-030E 1.74 1.85 2.02 2.17 2.23 2.37
ZXLE-040E 3.16 3.97 5.92 8.31 9.66 ZXLE-040E 2.61 2.85 3.30 3.72 3.93
ZXLE-050E 3.62 4.57 6.89 9.81 11.50 15.20 ZXLE-050E 2.94 3.18 3.61 4.00 4.18 4.56
ZXLE-060E 4.56 5.69 8.43 11.90 13.85 ZXLE-060E 3.70 4.04 4.70 5.33 5.64
ZXLE-075E 5.11 6.40 9.61 13.75 16.20 21.90 ZXLE-075E 3.85 4.18 4.77 5.31 5.59 6.16
Digital Medium Temperature Models
ZXDE-030E 3.43 5.13 6.14 8.47 ZXDE-030E 1.90 2.21 2.38 2.79
ZXDE-040E 4.75 7.21 8.69 12.25 ZXDE-040E 2.48 2.72 2.82 3.07
ZXDE-050E 5.83 8.65 10.35 14.40 ZXDE-050E 3.22 3.67 3.91 4.43
ZXDE-060E 6.82 10.10 12.00 16.60 ZXDE-060E 3.88 4.46 4.78 5.47
ZXDE-075E 7.70 11.40 13.60 18.80 ZXDE-075E 4.22 4.83 5.14 5.83
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
** Single Phase Only
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 128


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R404A Evaporating Temperature (°C) R404A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-020E 2.44 3.58 4.24 5.70 ZXME-020E 1.75 1.77 1.77 1.82
ZXME-025E 2.94 4.24 5.01 6.80 ZXME-025E 1.72 1.88 1.95 2.04
ZXME-030E 3.69 5.24 6.15 8.19 ZXME-030E 2.38 2.50 2.57 2.72
ZXME-040E 4.94 6.99 8.16 10.80 ZXME-040E 3.21 3.41 3.52 3.75
ZXME-050E 6.39 9.12 10.70 14.35 ZXME-050E 3.96 4.15 4.26 4.49
ZXME-060E 7.34 10.40 12.20 16.20 ZXME-060E 4.57 4.83 4.97 5.28
ZXME-075E 8.37 11.90 13.90 18.50 ZXME-075E 5.11 5.40 5.55 5.89
Low Temperature Models
ZXLE-020E 1.79 2.30 3.51 4.93 5.71 7.33 ZXLE-020E 1.68 1.78 1.97 2.14 2.21 2.35
ZXLE-025E** 2.11 2.70 4.13 5.83 6.76 8.71 ZXLE-025E** 1.93 2.05 2.25 2.43 2.51 2.66
ZXLE-030E 2.55 3.13 4.53 6.30 7.34 9.73 ZXLE-030E 2.12 2.21 2.41 2.61 2.71 2.94
ZXLE-040E 3.96 4.86 6.95 9.40 10.75 13.50 ZXLE-040E 3.09 3.30 3.75 4.25 4.52 5.07
ZXLE-050E 4.50 5.51 7.92 10.75 12.30 15.60 ZXLE-050E 3.57 3.79 4.27 4.80 5.08 5.67
ZXLE-060E 5.65 6.85 9.60 12.85 14.60 18.45 ZXLE-060E 4.55 4.88 5.56 6.35 6.81 7.96
ZXLE-075E 6.35 7.75 11.05 15.05 17.35 22.50 ZXLE-075E 4.74 5.05 5.68 6.36 6.74 7.68
Digital Medium Temperature Models
ZXDE-030E 3.67 5.27 6.19 8.21 ZXDE-030E 2.07 2.29 2.40 2.61
ZXDE-040E 5.29 7.58 8.94 12.15 ZXDE-040E 2.73 2.96 3.06 3.28
ZXDE-050E 6.36 9.03 10.60 14.10 ZXDE-050E 3.58 4.02 4.25 4.70
ZXDE-060E 7.42 10.45 12.20 16.05 ZXDE-060E 4.31 4.88 5.18 5.77
ZXDE-075E 8.39 11.80 13.80 18.25 ZXDE-075E 4.69 5.31 5.62 6.26
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
** Single Phase Only
Preliminary Data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R134a Evaporating Temperature (°C) R134a Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-020E 1.42 2.25 2.77 4.04 ZXME-020E 0.97 1.01 1.03 1.10
ZXME-025E 1.71 2.65 3.23 4.65 ZXME-025E 1.01 1.12 1.17 1.27
ZXME-030E 2.06 3.24 3.99 5.81 ZXME-030E 1.33 1.39 1.43 1.53
ZXME-040E 2.78 4.36 5.35 7.76 ZXME-040E 1.74 1.83 1.89 2.04
ZXME-050E 3.38 5.49 6.77 9.87 ZXME-050E 2.15 2.29 2.36 2.51
ZXME-060E 4.20 6.51 8.03 11.70 ZXME-060E 2.51 2.65 2.74 2.95
ZXME-075E 4.76 7.46 9.13 13.15 ZXME-075E 3.06 3.19 3.31 3.57
Digital Medium Temperature Models
ZXDE-030E 2.16 3.33 4.02 5.70 ZXDE-030E 1.27 1.43 1.51 1.70
ZXDE-040E 4.29 5.34 7.97 ZXDE-040E 1.82 1.86 1.95
ZXDE-050E 5.26 6.53 9.68 ZXDE-050E 2.31 2.38 2.53
ZXDE-060E 6.34 7.88 11.65 ZXDE-060E 2.72 2.81 3.03
ZXDE-075E 7.21 8.82 12.70 ZXDE-075E 2.96 3.04 3.26

Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
** Single Phase Only
Preliminary Data

129 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R450A Evaporating Temperature (°C) R450A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-020E 1.20 1.97 2.46 3.65 ZXME-020E 0.89 0.88 0.87 0.90
ZXME-025E 1.41 2.28 2.83 4.22 ZXME-025E 1.00 1.01 1.02 1.07
ZXME-030E 1.81 2.91 3.61 5.31 ZXME-030E 1.19 1.21 1.23 1.30
ZXME-040E 2.45 3.94 4.87 7.14 ZXME-040E 1.58 1.61 1.63 1.72
ZXME-050E 3.09 4.96 6.14 9.08 ZXME-050E 2.05 2.08 2.11 2.21
ZXME-060E 3.61 5.78 7.14 10.50 ZXME-060E 2.34 2.38 2.41 2.54
ZXME-075E 4.04 6.48 8.01 11.80 ZXME-075E 2.62 2.67 2.71 2.86
Digital Medium Temperature Models
ZXDE-030E 1.83 2.93 3.60 5.22 ZXDE-030E 1.07 1.15 1.18 1.25
ZXDE-040E 3.99 4.86 7.04 ZXDE-040E 1.42 1.48 1.62
ZXDE-050E 4.88 5.91 8.47 ZXDE-050E 1.86 1.98 2.22
ZXDE-060E 5.74 6.95 9.91 ZXDE-060E 2.20 2.35 2.66
ZXDE-075E 6.47 7.84 11.20 ZXDE-075E 2.39 2.55 2.89
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary Data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R513A Evaporating Temperature (°C) R513A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-020E 1.47 2.34 2.87 4.17 ZXME-020E 1.04 1.03 1.03 1.06
ZXME-025E 1.72 2.71 3.33 4.86 ZXME-025E 1.17 1.19 1.21 1.26
ZXME-030E 2.20 3.44 4.20 6.04 ZXME-030E 1.40 1.44 1.47 1.55
ZXME-040E 2.97 4.63 5.68 8.19 ZXME-040E 1.87 1.93 1.96 2.08
ZXME-050E 3.77 5.89 7.23 10.45 ZXME-050E 2.39 2.46 2.50 2.63
ZXME-060E 4.39 6.84 8.37 12.05 ZXME-060E 2.75 2.83 2.88 3.03
ZXME-075E 4.91 7.65 9.36 13.50 ZXME-075E 3.08 3.18 3.24 3.42
Digital Medium Temperature Models
ZXDE-030E 2.22 3.47 4.21 5.99 ZXDE-030E 1.25 1.35 1.39 1.49
ZXDE-040E 4.78 5.77 8.22 ZXDE-040E 1.70 1.77 1.93
ZXDE-050E 5.81 6.98 9.81 ZXDE-050E 2.26 2.40 2.68
ZXDE-060E 6.83 8.19 11.40 ZXDE-060E 2.69 2.87 3.24
ZXDE-075E 7.70 9.23 12.90 ZXDE-075E 2.92 3.12 3.51
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 130


131 GPC-EN-2024 REFRIGERATION APPLICATIONS
Copeland Small ZX outdoor refrigeration units with scroll compressors
Copeland small outdoor refrigeration units are for medium
temperature and low temperature applications.

These small ZX units help save space and time thanks to their
small footprint and plug & play installation. Thanks to their small
size and light weight, they can easily be installed on walls or roofs.

Copeland small ZX outdoor refrigeration units feature a low-


sound Copeland scroll compressor and a sickle blade fan for
quiet operation, which is important in urban environments and
residential areas.

Copeland small ZX
outdoor refrigeration unit

Copeland Small ZX line-up

Small ZXME for MT

Small ZXLE for LT

Capacity (kW)
R448A/R449A, EN13215 0 1 2 3

Features and benefits Maximum allowable pressures (PS)

• Standard equipment: Copeland scroll compressor, • Low Side PS 21 bar (g)


crankcase heater, liquid receiver, service valves, double • High Side PS 28.8 bar (g)
pressure switch, filter drier, sight glass, fan speed control,
external main power switch
• Energy and operation cost saving due to excellent energy
efficiency
• Noise attenuation thanks to fan motor with sickle blades and
fan speed control
• Increased reliability ensured by advanced factory tests
• Space saving thanks to small smallest footprint in its class
• Easy and quick ”plug & play” installation
• Multiple refrigerant approvals incl. R407A/F, R448A/R449A,
R404A, R134a, R450A and R513A

Technical overview
Maximum Locked
Diameter (inch)

Net Weight (kg)


Total Fan Motor

Diameter (inch)
Number of fans
Displacement

Motor
Suction Line
Capacity (l)

Liquid Line

Operating Rotor Sound


Power (W)

Width/
Receiver

Version/
(m3/h)

Depth/ Current Current Pressure


Model Code
Height (A) (A)
(mm) @10m -
1 Ph* 1 Ph* 1 Ph*
d(BA)**
Medium Temperature Models
ZXME-013E 3.7 1.8 1 54 1/2 3/8 900/350/600 51 PFJ 7.2 45 37
ZXME-015E 4.4 1.8 1 54 1/2 3/8 900/350/600 51 PFJ 8.7 45 37
ZXME-018E 5.0 1.8 1 54 1/2 3/8 900/350/600 51 PFJ 9.9 54 38
Low Temperature Models
ZXLE-018E 6.1 1.8 1 54 1/2 3/8 900/350/600 54 PFJ 13.6 57 37
ZXLE-023E 7.1 1.8 1 54 1/2 3/8 900/350/600 54 PFJ 15.6 74 37
ZXLE-028E 8.0 1.8 1 54 1/2 3/8 900/350/600 55 PFJ 17.8 82 38
* 1ph: 230V/ 50Hz
** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

GPC-EN-2024 REFRIGERATION APPLICATIONS 132


Capacity data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R448A/ R448A/
Evaporating Temperature (°C) Evaporating Temperature (°C)
R449A R449A
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-013E 1.39 2.00 2.36 3.32 ZXME-013E 0.96 1.06 1.12 1.27
ZXME-015E 1.66 2.35 2.76 3.85 ZXME-015E 1.10 1.23 1.30 1.49
ZXME-018E 1.87 2.62 3.07 4.25 ZXME-018E 1.29 1.46 1.55 1.78
Low Temperature Models
ZXLE-018E 1.59 2.07 2.97 ZXLE-018E 1.65 1.75 1.98
ZXLE-023E 1.75 2.08 2.98 ZXLE-023E 1.77 1.79 1.89
ZXLE-028E 2.00 2.51 3.84 ZXLE-028E 2.06 2.18 2.43
Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R404A Evaporating Temperature (°C) R404A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-013E 1.54 2.22 2.62 3.52 ZXME-013E 1.03 1.14 1.18 1.26
ZXME-015E 1.80 2.56 3.00 4.00 ZXME-015E 1.23 1.37 1.43 1.52
ZXME-018E 2.00 2.83 3.31 4.43 ZXME-018E 1.44 1.62 1.70 1.83
Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R134a Evaporating Temperature (°C) R134a Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-013E 0.91 1.40 1.70 2.43 ZXME-013E 0.62 0.69 0.72 0.79
ZXME-015E 1.08 1.64 1.99 2.82 ZXME-015E 0.73 0.82 0.87 0.97
ZXME-018E 1.82 2.19 3.07 ZXME-018E 0.97 1.03 1.17
Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R450A Evaporating Temperature (°C) R450A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-013E 0.76 1.26 1.51 2.10 ZXME-013E 0.56 0.62 0.65 0.71
ZXME-015E 0.84 1.43 1.68 2.44 ZXME-015E 0.65 0.73 0.78 0.87
ZXME-018E 0.92 1.60 1.85 2.60 ZXME-018E 0.73 0.87 0.92 1.05
Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R513A Evaporating Temperature (°C) R513A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
ZXME-013E 0.90 1.50 1.80 2.50 ZXME-013E 0.69 0.77 0.81 0.88
ZXME-015E 1.00 1.70 2.00 2.90 ZXME-015E 0.82 0.92 0.97 1.09
ZXME-018E 1.10 1.90 2.20 3.10 ZXME-018E 0.90 1.09 1.15 1.31
Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary data

133 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland ZX indoor refrigeration units with scroll compressors
The Copeland ZX indoor range is the ideal solution for urban
installations with space and noise constraints and also suits
applications in areas with extreme weather conditions.

Copeland refrigeration units have brought innovation to refrigeration


by providing solutions for quick and easy installation. Regular
communication between Copeland and its customers has resulted in
the latest indoor refrigeration unit design, taking this concept one step
further. The adoption of the popular ZX condensing unit design to the
needs of urban applications exactly meets customer needs.

Copeland ZX indoor refrigeration units feature the most complete
and unique equipment. Their advanced electronic controller enables
precise parameter control and displays the system status. Vapor
injection and liquid injection technology significantly increase
system efficiency and operation map. Electronic protection functions
and oil separator guarantee optimum system safety.

The units are prepared for standard air ducts, resulting in easy
installation and lower installation costs because they do not require:
• remote condenser
• additional E-box
• additional wiring and tubing

Lowest life cycle costs and comprehensive safety features make


Copeland ZX a cost efficient and reliable choice for: Copeland ZX indoor refrigeration units
• convenience stores
• cold rooms
• fast food stores, bars and restaurants
• service stations

Copeland ZX indoor line-up

ZXDI

Capacity (kW)
R448A/R449A, EN13215
0 5 10 15 20

Features and benefits

• Standard equipment: Copeland scroll compressor, • Noise attenuation due to low speed fan motors with
crankcase heater, electronic controller, fan(s) with speed sickle blades, fan speed control and sound jacket
control, liquid receiver, safety switches, filter drier, sight • Space saving due to compact dimensions
glass, and oil separator • Easy and quick installation
• Copeland ZX digital models allow for 10% to 100% • Multiple refrigerant approvals incl. R407A/F, R448A/
continuous capacity modulation R449A, R404A, R134a, R450A and R513A
• Diagnostic capabilities protect the unit from over-current,
phase loss and phase imbalance
• LED display shows real time system status Maximum allowable pressures (PS)
• Precise electronic suction pressure control
• Low Side PS 22.5 bar (g)
• Energy and operation cost saving due to excellent
• High Side PS 28.8 bar (g)
energy efficiency
• Prepared for standard air ducts
• Operation in urban environments or extreme weather
conditions

GPC-EN-2024 REFRIGERATION APPLICATIONS 134


Technical overview
Connection Lines
Total Fan Width/
Max. Diameter (inch) Max Sound
Displacement Number Motor Depth/ Weight
Model Operating Power
(m3/h)* of Fans Power Height (kg)
Current (A) dB(A)**
(W) Suction Liquid (mm)

Medium Temperature 380-420V / 50Hz / 3~

ZXDI-040E-TFD-554 11.4 7.7 2 750 7/8 1/2 1029/ 424/ 1242 138 86
ZXDI-050E-TFD-554 14.4 10.4 2 750 7/8 1/2 1029/ 424/ 1242 142 86
ZXDI-060E-TFD-554 17.1 11.6 2 750 7/8 1/2 1029/ 424/ 1242 146 86
ZXDI-075E-TFD-554 18.8 12.4 2 750 7/8 1/2 1029/ 424/ 1242 152 86
Conditions: EN13215: Evaporating -10°C, Ambient = 32°C, Suction Gas Return 20°C, Subcooling 0K
** Sound pressure depends on individual installation type

Capacity data
Capacity (kW)
Models
R134a R404A R407A R407F R448A R449A R450A R513A

ZXDI-040E-TFD-554 4.31 7.72 7.22 7.15 7.14 7.14 3.99 4.80

ZXDI-050E-TFD-554 5.35 9.42 8.69 8.70 8.68 8.68 4.92 5.90

ZXDI-060E-TFD-554 6.48 11.00 9.81 9.03 10.10 10.10 5.70 6.96

ZXDI-075E-TFD-554 7.35 12.50 11.40 10.35 11.55 11.55 6.55 7.86

*Conditions: EN13215: Evaporating -10°C, Ambient = 32°C, Suction Gas Return 20°C, Subcooling 0K
For detailed capacity data please refer to Copeland Select software

135 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland scroll indoor refrigeration units for refrigeration
Copeland air-cooled refrigeration units for medium temperature and low
temperature applications.

Copeland scroll refrigeration units are equipped with the latest


refrigeration scroll compressors and build the widest range of its kind.
The modular line concept offers base units which can be adapted to
the target application by various options including weather housings
and fan speed controls.

Copeland scroll refrigeration units are available with normal or high


capacity condensers to ensure optimum performance even under
extreme conditions. They are equipped with dedicated medium or low
temperature compressors which makes them suitable for all general
refrigeration applications, such as:
• Mini markets and supermarkets
• Bars, restaurants and kitchens
• Beer cellars and beverage coolers
• Cold rooms
Copeland scroll indoor refrigeration unit
• Milk cooling tank

Copeland scroll refrigeration units line-up

Medium Temperature Models

Low Temperature Models

Capacity (kW)
R448A/R449A, EN13215 0 5 10 15 20 25

Features and benefits Maximum allowable pressures (PS)

• Standard equipment: base plate, scroll compressor, crank • Low Side PS 22.5 bar (g)
case heater, condenser with 1ph fan(s), HP and LP • High Side PS = 28 bar (g)
switch, liquid receiver with rotalock-valve, suction- and
discharge shut-off valves
• Suitable for multiple refrigerants: R407A/F, R448A/R449A,
R404A, R134a, R450A and R513A
• Wide range of quality accessories
• Excellent efficiency and reliability

GPC-EN-2024 REFRIGERATION APPLICATIONS 136


Technical overview

Receiver Capacity

@10m - dB(A)***
Net Weight (kg)

Sound Pressure
Total Fan Motor

Diameter (inch)

Diameter (inch)
Number of fans
Displacement

Suction Line
Maximum

Liquid Line
Power (W)
Motor Version/ Locked Rotor
Operating

(m3/h)
Width/Depth/ Code Current (A)
Model

(l)
Height (mm) Current (A)

1 Ph* 3 Ph ** 1 Ph* 3 Ph ** 1 Ph* 3 Ph **


Medium Temperature Models
MC-D8-ZB15KE 5.9 3.9 1 110 3/4 1/2 560/570/446 48 PFJ TFD 13 5 58 26 45
MC-H8-ZB15KE 5.9 7.9 1 235 3/4 1/2 735/680/533 57 PFJ TFD 13 5 58 26 48
MC-D8-ZB19KE 6.8 3.9 1 110 3/4 1/2 560/570/446 49 PFJ TFD 13 7 61 32 45
MC-K9-ZB19KE 6.8 7.9 2 220 3/4 1/2 950/640/454 66 PFJ TFD 13 7 61 32 47
MC-H8-ZB19KE 6.8 7.9 1 235 3/4 1/2 735/680/533 61 PFJ TFD 13 7 61 32 48
MC-D8-ZB21KE 8.6 3.9 1 110 7/8 1/2 560/570/446 50 PFJ TFD 16 7 82 40 46
MC-H8-ZB21KE 8.6 7.9 1 235 7/8 1/2 735/680/533 61 PFJ TFD 16 7 82 40 48
MC-K9-ZB21KE 8.6 7.9 2 220 7/8 1/2 950/640/454 67 PFJ TFD 16 7 82 40 47
MC-K9-ZB26KE 10.0 7.9 2 220 7/8 1/2 950/640/454 68 PFJ TFD 18 9 97 46 47
MC-H8-ZB26KE 10.0 7.9 1 235 7/8 1/2 735/680/533 62 PFJ TFD 18 9 97 46 48
MC-H8-ZB30KE 11.7 7.9 1 235 7/8 1/2 735/680/533 74 PFJ TFD 26 10 142 49 49
MC-M8-ZB30KE 11.7 7.9 1 235 7/8 1/2 735/730/708 86 PFJ TFD 26 10 142 49 48
MC-P8-ZB30KE 11.7 7.9 2 220 7/8 1/2 950/640/633 86 TFD 10 49 48
MC-H8-ZB38KE 14.4 7.9 1 235 7/8 1/2 735/680/533 77 PFJ TFD 32 13 142 66 49
MC-M8-ZB38KE 14.4 7.9 1 235 7/8 1/2 735/730/708 89 PFJ TFD 32 13 142 66 48
MC-P8-ZB38KE 14.4 7.9 2 220 7/8 1/2 950/640/633 89 PFJ TFD 32 13 142 66 48
MC-M8-ZB42KE 16.2 7.9 1 235 7/8 1/2 735/730/708 91 PFJ 36 150 49
MC-R7-ZB42KE 16.2 7.9 2 470 7/8 1/2 1130/680/633 101 PFJ 36 150 52
MC-M8-ZB45KE 17.1 7.9 1 235 7/8 1/2 735/730/708 91 TFD 13 74 49
MC-M9-ZB45KE 17.1 7.9 1 400 7/8 1/2 735/730/708 95 TFD 13 74 49
MC-R7-ZB45KE 17.1 7.9 2 470 7/8 1/2 1130/680/633 101 TFD 13 74 49
MC-R7-ZB50KE 19.8 7.9 2 470 1 3/8 1/2 1130/820/621 110 TFD 15 100 49
MC-S9-ZB50KE 22.1 11.7 2 470 1 /8 3 5/8 1130/820/703 113 TFD 15 100 49
MC-R7-ZB58KE 22.1 7.9 2 470 1 3/8 1/2 1130/820/621 110 TFD 16 95
MC-S9-ZB58KE 22.1 11.7 2 470 1 3/8 5/8 1130/820/703 113 TFD 16 95
MC-S9-ZB66KE 24.9 11.7 2 470 1 3/8 5/8 1130/820/707 116 TFD 18 111 50
MC-V9-ZB66KE 24.9 15.8 2 470 1 /8 3 3/4 1330/820/821 150 TFD 18 111 50
MC-V9-ZB76KE 29.1 15.8 2 470 1 3/8 3/4 1330/820/835 151 TFD 20 118 50
MC-V6-ZB76KE 29.1 15.8 2 800 1 /8 3 3/4 1330/820/835 168 TFD 20 118 54
MC-V9-ZB95KE 36.4 15.8 2 470 1 /8 3 3/4 1330/820/835 155 TFD 28 140 50
MC-V6-ZB95KE 36.4 15.8 2 800 1 /8 3 3/4 1330/820/835 172 TFD 28 140 54
MC-V6-ZB114KE 43.3 15.8 2 800 1 /8 3 3/4 1330/820/835 174 TFD 33 174 54
MC-W9-ZB114KE 43.3 15.8 2 800 1 /8 3 3/4 1640/820/864 174 TFD 33 174 54

Digital Medium Temperature Models


MC-M8-ZBD30 11.7 11.7 1 235 7/8 5/8 735/730/708 86 TFD 8 52 48
MC-M9-ZBD45 17.1 11.7 1 400 7/8 5/8 735/730/708 95 TFD 12 74 49
MC-V6-ZBDT60 23.4 18.9 2 800 1 /8 3 3/4 1330/820/835 207 TFD 8+10 57
MC-V6-ZBDT90 34.1 18.9 2 800 1 /8 3 3/4 1330/820/835 218 TFD 12+13 57
* 1ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

137 GPC-EN-2024 REFRIGERATION APPLICATIONS


Technical overview

Total Fan Motor Power

Suction Line Diameter

Liquid Line Diameter


Receiver Capacity (l)
Displacement (m3/h)
Maximum

@10m - dB(A)***
Number of Fans

Net Weight (kg)

Sound Pressure
Motor Version/ Locked Rotor
Operating
Code Current (A)
Current (A)

(inch)

(inch)
Width/Depth/

(W)
Models
Height (mm)

1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**

Low Temperature Models


MC-D8-ZF09KE 3.9 3.9 1 110 7/8 1/2 560/570/446 64 TFD 6 40 46
MC-H8-ZF09KE 7.9 7.9 1 235 7/8 1/2 735/680/533 66 TFD 6 40 49
MC-H8-ZF13KE 7.9 7.9 1 235 7/8 1/2 735/680/533 77 TFD 8 52 49
MC-M8E-ZF11KE 9.9 7.9 1 180 7/8 1/2 736/730/705 96 TFD 7 46 48
MC-M8-ZF13KE 7.9 7.9 1 235 7/8 1/2 735/730/708 85 TFD 8 52 49
MC-M8-ZF15KE 7.9 7.9 1 235 7/8 1/2 735/730/708 86 TFD 10 64 49
MC-M8-ZF18KE 7.9 7.9 1 235 7/8 1/2 735/730/708 88 TFD 13 74 49
MC-S9-ZF18KE 7.9 7.9 2 470 1 3/8 1/2 1130/680/708 168 TFD 13 74
MC-S9-ZF25K5 11.7 11.7 2 470 1 1/8 5/8 1130/680/703 117 TFD 16 102 54
MC-S9-ZF34K5 11.7 11.7 2 470 1 /8 1
5/8 1130/680/703 141 TFD 25 100 54
MC-V6-ZF41K5 11.7 11.7 2 800 1 3/8 5/8 1330/820/830 168 TFD 29 118 57
MC-V6-ZF49K5 11.7 11.7 2 800 1 /8 3
3/4 1330/820/830 185 TFD 30 139 57
* 1ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

GPC-EN-2024 REFRIGERATION APPLICATIONS 138


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R407A Evaporating Temperature (°C) R407A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
MC-H8-ZB15KE 3.45 4.15 5.86 MC-H8-ZB15KE 1.73 1.78 1.89
MC-D8-ZB15KE 3.22 3.83 5.32 MC-D8-ZB15KE 1.79 1.87 2.06
MC-D8-ZB19KE 3.64 4.34 5.94 MC-D8-ZB19KE 1.96 2.08 2.30
MC-K9-ZB19KE 3.94 4.76 6.67 MC-K9-ZB19KE 1.85 1.93 2.07
MC-H8-ZB19KE 3.95 4.77 6.69 MC-H8-ZB19KE 1.85 1.94 2.07
MC-K9-ZB21KE 4.78 5.75 7.97 MC-K9-ZB21KE 2.47 2.61 2.83
MC-H8-ZB21KE 4.80 5.77 8.01 MC-H8-ZB21KE 2.48 2.61 2.83
MC-D8-ZB21KE 4.15* 5.08 MC-D8-ZB21KE 2.72* 2.95
MC-H8-ZB26KE 5.39 6.42 8.87 MC-H8-ZB26KE 2.89 3.04 3.36
MC-K9-ZB26KE 5.37 6.39 8.83 MC-K9-ZB26KE 2.89 3.04 3.37
MC-H8-ZB30KE 5.93* 7.33 MC-H8-ZB30KE 3.51* 3.71
MC-M8-ZB30KE 6.44 7.76 10.80 MC-M8-ZB30KE 3.28 3.41 3.74
MC-P8-ZB30KE 6.49 7.82 10.90 MC-P8-ZB30KE 3.23 3.36 3.67
MC-H8-ZB38KE 7.23* 8.59* MC-H8-ZB38KE 4.53* 4.85*
MC-M8-ZB38KE 7.73* 9.48 MC-M8-ZB38KE 4.17* 4.47
MC-P8-ZB38KE 7.81* 9.58 12.95 MC-P8-ZB38KE 4.10* 4.39 4.99
MC-M8-ZB42KE** 5.58* 8.23* 10.00 13.35 MC-M8-ZB42KE** 4.59* 5.13* 5.49 6.02
MC-R7-ZB42KE** 6.01* 9.28 11.05 15.25 MC-R7-ZB42KE** 4.39* 4.81 4.99 5.34
MC-M8-ZB45KE 8.48* 10.30 MC-M8-ZB45KE 5.17* 5.57
MC-M9-ZB45KE 9.26 11.00 14.90 MC-M9-ZB45KE 5.06 5.30 5.81
MC-R7-ZB45KE 9.58 11.45 15.70 MC-R7-ZB45KE 4.89 5.08 5.49
MC-R7-ZB50KE 10.95 13.15 18.00 MC-R7-ZB50KE 6.00 6.29 6.89
MC-S9-ZB50KE 11.40 13.70 18.95 MC-S9-ZB50KE 5.70 5.93 6.41
MC-R7-ZB58KE 11.05* 13.80 MC-R7-ZB58KE 6.61* 7.06
MC-S9-ZB58KE 11.90 14.50 20.40 MC-S9-ZB58KE 6.33 6.66 7.41
MC-S9-ZB66KE 13.15 15.85 21.90 MC-S9-ZB66KE 7.25 7.68 8.65
MC-V9-ZB66KE 13.75 16.65 23.20 MC-V9-ZB66KE 6.92 7.26 8.08
MC-V9-ZB76KE 15.75 19.00 26.30 MC-V9-ZB76KE 8.21 8.71 9.81
MC-V6-ZB76KE 16.65 20.20 28.40 MC-V6-ZB76KE 8.01 8.39 9.22
MC-V9-ZB95KE 17.35* 21.50 MC-V9-ZB95KE 11.25* 12.10
MC-V6-ZB95KE 19.45 23.50 32.60 MC-V6-ZB95KE 10.70 11.30 12.60
MC-V6-ZB114KE 21.40* 26.80 MC-V6-ZB114KE 13.00* 13.90
MC-W9-ZB114KE 22.50 27.40 38.40 MC-W9-ZB114KE 12.85 13.60 15.40
Low Temperature Models
MC-D8-ZF09KE 1.58 1.99 2.99 4.27 5.01 6.62* MC-D8-ZF09KE 1.65 1.70 1.87 2.14 2.33 2.79*
MC-H8-ZF09KE 1.66 2.09 3.19 4.65 5.52 7.57 MC-H8-ZF09KE 1.67 1.70 1.84 2.08 2.25 2.68
MC-H8-ZF13KE 2.25 2.83 4.31 6.25 7.39 10.00 MC-H8-ZF13KE 2.45 2.59 2.92 3.39 3.71 4.55
MC-M8-ZF13KE 2.29 2.89 4.43 6.48 7.72 10.60 MC-M8-ZF13KE 2.37 2.49 2.77 3.16 3.43 4.16
MC-M8-ZF15KE 2.77 3.49 5.29 7.64 9.02 12.15 MC-M8-ZF15KE 2.88 3.09 3.57 4.22 4.66 5.80
MC-M8-ZF18KE 3.31 4.15 6.23 8.88 10.40 13.65* MC-M8-ZF18KE 3.60 3.83 4.39 5.13 5.61 6.78*
MC-S9-ZF18KE 3.46 4.38 6.73 9.88 11.80 16.25 MC-S9-ZF18KE 3.53 3.70 4.07 4.58 4.91 5.77
MC-S9-ZF25K5 4.38 5.53 8.48 12.40 14.75 MC-S9-ZF25K5 4.29 4.61 5.33 6.18 6.66
MC-S9-ZF34K5 5.91 7.47 11.35 16.40 19.35 MC-S9-ZF34K5 5.61 6.15 7.41 8.99 9.92
MC-V6-ZF41K5 7.44 9.37 14.20 20.60 24.40 MC-V6-ZF41K5 6.76 7.35 8.65 10.20 11.05
MC-V6-ZF49K5 8.73 11.05 16.90 24.50 29.10 MC-V6-ZF49K5 8.30 9.05 10.75 12.75 13.85
Digital Medium Temperature Models
MC-M8-ZBD30KE 6.76 8.10 11.10 MC-M8-ZBD30KE 3.39 3.56 3.98
MC-M9-ZBD45KE 9.18 11.00 14.95 MC-M9-ZBD45KE 4.90 5.17 5.80
MC-V6-ZBDT60KE 9.39 14.40 17.40 24.30 MC-V6-ZBDT60KE 6.02 6.42 6.67 7.25
MC-V6-ZBDT90KE 12.70 19.05 22.80 31.40 MC-V6-ZBDT90KE 8.78 9.48 9.90 10.85
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
** Single Phase only
Preliminary Data
139 GPC-EN-2024 REFRIGERATION APPLICATIONS
Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R407F Evaporating Temperature (°C) R407F Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
MC-D8-ZB15KE 3.04 3.66 5.04 MC-D8-ZB15KE 1.96 2.02 2.17
MC-H8-ZB15KE 3.36 4.07 5.70 MC-H8-ZB15KE 1.84 1.87 1.93
MC-D8-ZB19KE 3.51* 4.30 5.87 MC-D8-ZB19KE 2.37* 2.52 2.84
MC-H8-ZB19KE 4.02 4.84 6.74 MC-H8-ZB19KE 2.21 2.29 2.46
MC-K9-ZB19KE 4.01 4.82 6.72 MC-K9-ZB19KE 2.20 2.29 2.46
MC-K9-ZB21KE 4.69 5.62 7.72 MC-K9-ZB21KE 2.72 2.85 3.11
MC-H8-ZB21KE 4.71 5.65 7.76 MC-H8-ZB21KE 2.72 2.85 3.11
MC-H8-ZB26KE 5.12* 6.28 8.64 MC-H8-ZB26KE 3.26* 3.46 3.85
MC-K9-ZB26KE 5.10* 6.25 8.59 MC-K9-ZB26KE 3.27* 3.47 3.86
MC-H8-ZB30KE 6.06* 7.47 MC-H8-ZB30KE 3.80* 4.05
MC-P8-ZB30KE 4.10* 6.64 8.03 11.25 MC-P8-ZB30KE 3.22* 3.49 3.64 4.01
MC-M8-ZB30KE 4.06* 6.58 7.96 11.15 MC-M8-ZB30KE 3.26* 3.55 3.70 4.10
MC-H8-ZB38KE 6.97* 8.40* MC-H8-ZB38KE 5.11* 5.47*
MC-P8-ZB38KE 7.67* 9.44 MC-P8-ZB38KE 4.61* 4.88
MC-M8-ZB38KE 7.58* 9.32 MC-M8-ZB38KE 4.69* 4.98
MC-M8-ZB45KE 8.59* 10.30* MC-M8-ZB45KE 5.71* 6.10*
MC-R7-ZB45KE 6.15* 9.71 11.70 16.35 MC-R7-ZB45KE 4.77* 5.19 5.41 5.96
MC-M9-ZB45KE 9.15* 11.20 15.50 MC-M9-ZB45KE 5.40* 5.71 6.40
MC-R7-ZB58KE 11.70* 14.55 MC-R7-ZB58KE 7.09* 7.62
MC-S9-ZB58KE 7.13* 12.40* 15.40 21.50 MC-S9-ZB58KE 5.97* 6.73* 7.16 8.06
MC-S9-ZB66KE 13.60* 16.75 MC-S9-ZB66KE 7.74* 8.26
MC-V9-ZB66KE 8.66* 14.60 17.70 24.60 MC-V9-ZB66KE 6.58* 7.37 7.76 8.70
MC-V9-ZB76KE 9.76* 16.30* 20.10 27.80 MC-V9-ZB76KE 7.61* 8.73* 9.36 10.70
MC-V6-ZB76KE 10.55* 17.75 21.60 30.20 MC-V6-ZB76KE 7.61* 8.49 8.93 9.92
MC-V6-ZB114KE 22.60* 28.20 MC-V6-ZB114KE 14.00* 15.05
MC-W9-ZB114KE 13.25* 23.20* 29.00 MC-W9-ZB114KE 12.10* 13.70* 14.65
Low Temperature Models
MC-H8-ZF09KE 1.74 2.19 3.34 4.86 5.77 7.88 MC-H8-ZF09KE 1.75 1.79 1.94 2.20 2.37 2.83
MC-D8-ZF09KE 1.65 2.08 3.12 4.44 5.20 MC-D8-ZF09KE 1.75 1.80 1.98 2.28 2.47
MC-H8-ZF13KE 2.36 2.96 4.50 6.51 7.69 MC-H8-ZF13KE 2.59 2.75 3.11 3.63 3.97
MC-M8-ZF13KE 2.40 3.03 4.64 6.77 8.05 11.00 MC-M8-ZF13KE 2.50 2.63 2.93 3.37 3.66 4.45
MC-M8-ZF15KE 2.90 3.65 5.53 7.95 9.37 MC-M8-ZF15KE 3.04 3.27 3.80 4.51 4.99
MC-M8-ZF18KE 3.47 4.34 6.50 9.22 10.80 MC-M8-ZF18KE 3.81 4.07 4.68 5.49 6.01
MC-S9-ZF18KE 3.64 4.60 7.05 10.35 12.30 16.95 MC-S9-ZF18KE 3.71 3.89 4.30 4.85 5.20 6.13
Digital Medium Temperature Models
MC-M8-ZBD30KE 4.57* 6.82 8.06 10.90 MC-M8-ZBD30KE 2.78* 3.32 3.58 4.14

MC-M9-ZBD45KE 9.44* 11.55 15.50 MC-M9-ZBD45KE 5.05* 5.54 6.58

MC-V6-ZBDT60KE 9.12* 14.25 17.15 24.00 MC-V6-ZBDT60KE 6.05* 6.65 6.94 7.59
MC-V6-ZBDT90KE 12.10* 19.70 23.70 32.60 MC-V6-ZBDT90KE 8.73* 10.05 10.70 12.15
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 140


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R448A Evaporating Temperature (°C) R448A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
MC-D8-ZB15KE 2.16 3.29 3.94 5.40 MC-D8-ZB15KE 1.72 1.80 1.86 2.03
MC-H8-ZB15KE 2.29 3.54 4.29 6.03 MC-H8-ZB15KE 1.67 1.70 1.74 1.84
MC-D8-ZB19KE 2.39* 3.71 4.41 5.95 MC-D8-ZB19KE 1.88* 2.04 2.14 2.41
MC-H8-ZB19KE 2.66 4.04 4.87 6.77 MC-H8-ZB19KE 1.82 1.91 1.98 2.16
MC-K9-ZB19KE 2.66 4.03 4.85 6.75 MC-K9-ZB19KE 1.81 1.90 1.97 2.16
MC-D8-ZB21KE 2.89* 4.44 5.22 6.86 MC-D8-ZB21KE 2.51* 2.83 3.02 3.46
MC-H8-ZB21KE 3.30 4.94 5.89 8.06 MC-H8-ZB21KE 2.34 2.52 2.64 2.92
MC-K9-ZB21KE 3.29 4.92 5.87 8.02 MC-K9-ZB21KE 2.34 2.52 2.64 2.92
MC-H8-ZB26KE 3.65 5.46 6.52 8.94 MC-H8-ZB26KE 2.74 2.96 3.09 3.39
MC-K9-ZB26KE 3.64 5.44 6.49 8.90 MC-K9-ZB26KE 2.74 2.96 3.10 3.40
MC-H8-ZB30KE 4.02* 6.37 7.55 10.25 MC-H8-ZB30KE 3.24* 3.58 3.76 4.24
MC-P8-ZB30KE 4.43 6.72 8.01 11.00 MC-P8-ZB30KE 3.05 3.28 3.42 3.79
MC-M8-ZB30KE 4.40 6.67 7.95 10.90 MC-M8-ZB30KE 3.09 3.33 3.48 3.86
MC-P8-ZB38KE 5.08* 8.03 9.53 12.95 MC-P8-ZB38KE 3.93* 4.33 4.55 5.12
MC-M8-ZB38KE 5.03* 7.96 9.43 12.80 MC-M8-ZB38KE 3.98* 4.41 4.64 5.23
MC-H8-ZB38KE 4.74* 7.49 8.82 MC-H8-ZB38KE 4.25* 4.81 5.11
MC-M8-ZB42KE** 5.51* 8.70 10.30 13.85 MC-M8-ZB42KE** 4.61* 5.16 5.46 6.22
MC-R7-ZB42KE** 6.26 9.52 11.35 15.60 MC-R7-ZB42KE** 4.42 4.74 4.93 5.43
MC-M8-ZB45KE 5.68* 8.98 10.60 14.25 MC-M8-ZB45KE 4.66* 5.24 5.55 6.33
MC-R7-ZB45KE 6.48 9.84 11.75 16.10 MC-R7-ZB45KE 4.46 4.80 4.99 5.51
MC-M9-ZB45KE 6.28 9.49 11.25 15.35 MC-M9-ZB45KE 4.58 4.99 5.23 5.85
MC-R7-ZB58KE 7.12* 11.95 14.40 19.65 MC-R7-ZB58KE 6.09* 6.76 7.15 8.10
MC-S9-ZB58KE 7.49* 12.50 15.10 20.80 MC-S9-ZB58KE 5.86* 6.40 6.71 7.51
MC-S9-ZB66KE 8.64* 13.85 16.50 22.40 MC-S9-ZB66KE 6.71* 7.37 7.75 8.74
MC-V9-ZB66KE 8.99* 14.45 17.30 23.70 MC-V9-ZB66KE 6.45* 6.97 7.28 8.12
MC-V6-ZB76KE 10.85* 17.45 21.00 29.00 MC-V6-ZB76KE 7.44* 8.03 8.38 9.29
MC-V9-ZB76KE 10.30* 16.55 19.80 26.90 MC-V9-ZB76KE 7.49* 8.31 8.78 9.95
MC-V9-ZB95KE 11.20* 18.80 22.50 30.20 MC-V9-ZB95KE 10.20* 11.50 12.25 14.15
MC-W9-ZB114KE 14.05* 23.60 28.50 39.30 MC-W9-ZB114KE 11.90* 13.05 13.75 15.60
MC-V6-ZB114KE 13.75* 23.10 27.90 38.30 MC-V6-ZB114KE 12.15* 13.35 14.10 16.05
Low Temperature Models
MC-D8-ZF09KE 1.66 2.07 3.09 4.38 5.14 MC-D8-ZF09KE 1.58 1.68 1.93 2.28 2.49
MC-H8-ZF09KE 1.71 2.15 3.26 4.72 5.61 MC-H8-ZF09KE 1.61 1.69 1.91 2.20 2.37
MC-H8-ZF13KE 2.44 3.06 4.58 6.53 7.66 MC-H8-ZF13KE 2.30 2.45 2.80 3.26 3.55
MC-M8-ZF13KE 2.48 3.12 4.71 6.78 8.00 MC-M8-ZF13KE 2.23 2.37 2.68 3.10 3.36
MC-M8-ZF15KE 3.02 3.76 5.58 7.86 9.17 MC-M8-ZF15KE 2.96 3.14 3.64 4.33 4.77
MC-M8-ZF18KE 3.56 4.48 6.65 9.26 10.75 MC-M8-ZF18KE 4.06 4.16 4.60 5.37 5.89
MC-S9-ZF18KE 3.79 4.79 7.23 10.40 12.25 MC-S9-ZF18KE 3.75 3.80 4.06 4.56 4.88
Digital Medium Temperature Models
MC-M8-ZBD30KE 4.55 6.79 8.09 11.05 MC-M8-ZBD30KE 2.72 3.20 3.47 4.09
MC-M9-ZBD45KE 6.52 9.72 11.55 15.55 MC-M9-ZBD45KE 4.00 4.78 5.20 6.14
MC-V6-ZBDT60KE 9.37 14.25 17.05 23.80 MC-V6-ZBDT60KE 5.77 6.33 6.64 7.40
MC-V6-ZBDT90KE 13.15 19.85 23.60 32.40 MC-V6-ZBDT90KE 8.29 9.32 9.90 11.25

Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
** Single Phase only
Preliminary Data

141 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R449A Evaporating Temperature (°C) R449A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
MC-D8-ZB15KE 2.16 3.29 3.94 5.40 MC-D8-ZB15KE 1.72 1.80 1.86 2.03
MC-H8-ZB15KE 2.29 3.54 4.29 6.03 MC-H8-ZB15KE 1.67 1.70 1.74 1.84
MC-D8-ZB19KE 2.39* 3.71 4.41 5.95 MC-D8-ZB19KE 1.88* 2.04 2.14 2.41
MC-H8-ZB19KE 2.66 4.04 4.87 6.77 MC-H8-ZB19KE 1.82 1.91 1.98 2.16
MC-K9-ZB19KE 2.66 4.03 4.85 6.75 MC-K9-ZB19KE 1.81 1.90 1.97 2.16
MC-D8-ZB21KE 2.89* 4.44 5.22 6.86 MC-D8-ZB21KE 2.51* 2.83 3.02 3.46
MC-H8-ZB21KE 3.30 4.94 5.89 8.06 MC-H8-ZB21KE 2.34 2.52 2.64 2.92
MC-K9-ZB21KE 3.29 4.92 5.87 8.02 MC-K9-ZB21KE 2.34 2.52 2.64 2.92
MC-H8-ZB26KE 3.65 5.46 6.52 8.94 MC-H8-ZB26KE 2.74 2.96 3.09 3.39
MC-K9-ZB26KE 3.64 5.44 6.49 8.90 MC-K9-ZB26KE 2.74 2.96 3.10 3.40
MC-H8-ZB30KE 4.01* 6.37 7.55 10.25 MC-H8-ZB30KE 3.23* 3.58 3.76 4.24
MC-P8-ZB30KE 4.43 6.72 8.01 11.00 MC-P8-ZB30KE 3.05 3.28 3.42 3.79
MC-M8-ZB30KE 4.40 6.68 7.95 10.90 MC-M8-ZB30KE 3.09 3.33 3.48 3.86
MC-P8-ZB38KE 5.07* 8.03 9.53 12.95 MC-P8-ZB38KE 3.92* 4.33 4.55 5.12
MC-M8-ZB38KE 5.03* 7.96 9.44 12.80 MC-M8-ZB38KE 3.98* 4.41 4.64 5.23
MC-H8-ZB38KE 4.73* 7.49 8.82 MC-H8-ZB38KE 4.25* 4.81 5.11
MC-M8-ZB42KE** 5.50* 8.70 10.30 13.85 MC-M8-ZB42KE** 4.61* 5.16 5.46 6.22
MC-R7-ZB42KE** 6.26 9.52 11.35 15.65 MC-R7-ZB42KE** 4.42 4.74 4.93 5.43
MC-M8-ZB45KE 5.67* 8.98 10.60 14.25 MC-M8-ZB45KE 4.66* 5.24 5.55 6.33
MC-R7-ZB45KE 6.48 9.84 11.75 16.10 MC-R7-ZB45KE 4.46 4.80 4.99 5.51
MC-M9-ZB45KE 6.28 9.50 11.25 15.35 MC-M9-ZB45KE 4.58 4.99 5.23 5.85
MC-R7-ZB50KE 6.88* 11.15 13.35 18.05 MC-R7-ZB50KE 5.32* 5.92 6.22 6.91
MC-S9-ZB50KE 7.17* 11.60 13.90 19.05 MC-S9-ZB50KE 5.12* 5.61 5.87 6.43
MC-R7-ZB56KE 7.36* 11.05 13.00 17.30 MC-R7-ZB56KE 5.69* 6.40 6.77 7.61
MC-S9-ZB56KE 7.57* 11.45 13.50 18.25 MC-S9-ZB56KE 5.49* 6.10 6.41 7.13
MC-R7-ZB58KE 7.11* 11.95 14.40 19.65 MC-R7-ZB58KE 6.09* 6.76 7.15 8.10
MC-S9-ZB58KE 7.48* 12.50 15.10 20.80 MC-S9-ZB58KE 5.86* 6.40 6.71 7.51
MC-S9-ZB66KE 8.62* 13.85 16.50 22.40 MC-S9-ZB66KE 6.70* 7.37 7.75 8.74
MC-V9-ZB66KE 8.98* 14.45 17.30 23.70 MC-V9-ZB66KE 6.44* 6.97 7.28 8.12
MC-V6-ZB76KE 10.85* 17.45 21.00 29.00 MC-V6-ZB76KE 7.43* 8.03 8.38 9.29
MC-V9-ZB76KE 10.25* 16.55 19.80 26.90 MC-V9-ZB76KE 7.49* 8.31 8.78 9.95
MC-V6-ZB95KE 12.30* 20.50 24.50 33.40 MC-V6-ZB95KE 9.87* 10.80 11.40 12.80
MC-V9-ZB95KE 11.15* 18.80 22.50 30.20 MC-V9-ZB95KE 10.20* 11.50 12.25 14.15
MC-V6-ZB114KE 13.70* 23.10 27.90 38.30 MC-V6-ZB114KE 12.15* 13.35 14.10 16.05
MC-W9-ZB114KE 14.05* 23.60 28.50 39.30 MC-W9-ZB114KE 11.90* 13.05 13.75 15.60
Low Temperature Models
MC-D8-ZF09KE 1.66 2.07 3.09 4.38 5.14 MC-D8-ZF09KE 1.58 1.68 1.93 2.28 2.49
MC-H8-ZF09KE 1.71 2.15 3.26 4.72 5.61 MC-H8-ZF09KE 1.61 1.69 1.91 2.20 2.37
MC-H8-ZF13KE 2.44 3.06 4.58 6.53 7.66 MC-H8-ZF13KE 2.30 2.45 2.80 3.26 3.55
MC-M8-ZF13KE 2.48 3.12 4.71 6.78 8.00 MC-M8-ZF13KE 2.23 2.37 2.68 3.10 3.36
MC-M8-ZF15KE 3.02 3.76 5.58 7.86 9.17 MC-M8-ZF15KE 2.96 3.14 3.64 4.33 4.77
MC-M8-ZF18KE 3.56 4.48 6.65 9.26 10.75 MC-M8-ZF18KE 4.06 4.16 4.60 5.37 5.89
MC-S9-ZF18KE 3.79 4.79 7.23 10.40 12.25 MC-S9-ZF18KE 3.75 3.80 4.06 4.56 4.88
Digital Medium Temperature Models
MC-M8-ZBD30KE 4.55 6.79 8.09 11.05 MC-M8-ZBD30KE 2.72 3.20 3.47 4.09
MC-M9-ZBD45KE 6.52 9.72 11.55 15.55 MC-M9-ZBD45KE 4.00 4.78 5.20 6.14
MC-V6-ZBDT60KE 9.37 14.25 17.05 23.80 MC-V6-ZBDT60KE 5.77 6.33 6.64 7.40
MC-V6-ZBDT90KE 13.15 19.85 23.60 32.40 MC-V6-ZBDT90KE 8.29 9.32 9.90 11.25

Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
** Single Phase only
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 142


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R404A Evaporating Temperature (°C) R404A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
MC-D8-ZB15KE 2.24 3.25 3.81 5.02 MC-D8-ZB15KE 1.93 1.98 2.01 2.09
MC-H8-ZB15KE 2.46 3.62 4.29 5.80 MC-H8-ZB15KE 1.85 1.86 1.86 1.91
MC-D8-ZB19KE 2.63 3.68 4.27 5.57 MC-D8-ZB19KE 2.22 2.37 2.45 2.64
MC-H8-ZB19KE 2.86 4.09 4.81 6.47 MC-H8-ZB19KE 2.11 2.20 2.25 2.37
MC-K9-ZB19KE 2.86 4.10 4.83 6.50 MC-K9-ZB19KE 2.09 2.18 2.23 2.35
MC-K9-ZB21KE 3.60 5.09 5.94 7.83 MC-K9-ZB21KE 2.56 2.71 2.79 2.97
MC-D8-ZB21KE 3.20 4.38 5.02 6.37 MC-D8-ZB21KE 2.82 3.07 3.20 3.49
MC-H8-ZB21KE 3.59 5.07 5.91 7.79 MC-H8-ZB21KE 2.59 2.74 2.82 3.00
MC-H8-ZB26KE 4.05 5.65 6.57 8.64 MC-H8-ZB26KE 3.11 3.30 3.41 3.67
MC-K9-ZB26KE 4.06 5.68 6.60 8.69 MC-K9-ZB26KE 3.08 3.27 3.38 3.63
MC-H8-ZB30KE 4.55 6.35 7.36 9.60 MC-H8-ZB30KE 3.66 3.91 4.06 4.41
MC-P8-ZB30KE 4.96 7.06 8.28 11.05 MC-P8-ZB30KE 3.30 3.45 3.54 3.76
MC-M8-ZB30KE 4.81 6.80 7.94 10.50 MC-M8-ZB30KE 3.44 3.63 3.74 4.00
MC-H8-ZB38KE 5.34 7.30 8.38 10.70 MC-H8-ZB38KE 4.77 5.19 5.43 5.97
MC-P8-ZB38KE 5.95 8.35 9.73 12.85 MC-P8-ZB38KE 4.24 4.53 4.69 5.06
MC-M8-ZB38KE 5.72 7.96 9.23 12.00 MC-M8-ZB38KE 4.44 4.78 4.97 5.40
MC-M8-ZB42KE** 6.30 8.66 9.96 12.75 MC-M8-ZB42KE** 5.13 5.57 5.81 6.32
MC-R7-ZB42KE** 6.92 9.77 11.40 15.10 MC-R7-ZB42KE** 4.81 5.09 5.24 5.57
MC-M8-ZB45KE 6.49 8.92 10.25 13.15 MC-M8-ZB45KE 5.28 5.72 5.96 6.47
MC-R7-ZB45KE 7.14 10.10 11.75 15.55 MC-R7-ZB45KE 4.98 5.26 5.41 5.75
MC-M9-ZB45KE 6.87 9.59 11.10 14.50 MC-M9-ZB45KE 5.13 5.48 5.66 6.08
MC-S9-ZB45KE 7.37 10.50 12.30 16.45 MC-S9-ZB45KE 4.80 5.03 5.15 5.42
MC-R7-ZB50KE 7.53 11.40 13.40 17.65 MC-R7-ZB50KE 6.02 6.47 6.69 7.16
MC-S9-ZB50KE 7.94 12.00 14.20 18.90 MC-S9-ZB50KE 5.76 6.11 6.29 6.68
MC-R7-ZB58KE 8.48 12.35 14.45 18.75 MC-R7-ZB58KE 6.73 7.31 7.62 8.28
MC-S9-ZB58KE 8.94 13.10 15.35 20.30 MC-S9-ZB58KE 6.41 6.89 7.14 7.71
MC-S9-ZB66KE 10.30 14.45 16.75 21.70 MC-S9-ZB66KE 7.35 7.92 8.23 8.93
MC-V9-ZB66KE 10.65 15.05 17.55 23.00 MC-V9-ZB66KE 7.07 7.57 7.83 8.46
MC-V9-ZB76KE 12.15 17.15 19.90 25.80 MC-V9-ZB76KE 8.27 9.02 9.42 10.30
MC-V6-ZB76KE 12.90 18.45 21.60 28.70 MC-V6-ZB76KE 8.04 8.61 8.91 9.58
MC-V9-ZB95KE 12.15* 19.30 22.40 28.70 MC-V9-ZB95KE 11.15* 12.40 12.95 14.30
MC-V6-ZB95KE 14.85 21.50 25.20 33.10 MC-V6-ZB95KE 10.70 11.40 11.85 12.95
MC-V6-ZB114KE 15.05* 24.30 28.40 37.30 MC-V6-ZB114KE 13.05* 14.25 14.80 16.20
MC-W9-ZB114KE 16.80 24.60 28.80 38.00 MC-W9-ZB114KE 13.15 14.05 14.60 15.95
Low Temperature Models
MC-D8-ZF09KE 1.89 2.30 3.25 4.37 4.98 6.31 MC-D8-ZF09KE 1.97 2.05 2.26 2.57 2.76 3.20
MC-H8-ZF09KE 1.99 2.45 3.55 4.91 5.70 7.47 MC-H8-ZF09KE 1.96 2.02 2.21 2.47 2.63 3.01
MC-H8-ZF13KE 2.76 3.38 4.85 6.60 7.57 9.68 MC-H8-ZF13KE 2.60 2.73 3.07 3.51 3.76 4.34
MC-M8-ZF13KE 2.83 3.49 5.08 7.01 8.11 10.55 MC-M8-ZF13KE 2.51 2.63 2.94 3.33 3.56 4.09
MC-M8-ZF15KE 3.40 4.16 5.94 8.06 9.23 11.70 MC-M8-ZF15KE 3.29 3.52 4.04 4.69 5.08 6.01
MC-M8-ZF18KE 3.90 4.79 6.80 9.15 10.45 13.30 MC-M8-ZF18KE 4.04 4.25 4.77 5.45 5.86 6.82
MC-S9-ZF18KE 4.22 5.22 7.61 10.60 12.35 16.45 MC-S9-ZF18KE 3.84 3.98 4.36 4.86 5.15 5.85
MC-S9-ZF25K5 5.27 6.46 9.34 12.95 15.05 19.80 MC-S9-ZF25K5 4.16 4.50 5.23 6.06 6.51 7.52
MC-R7-ZF33KE 6.76 8.21 11.50 15.25 17.30 MC-R7-ZF33KE 6.59 7.14 8.32 9.64 10.35
MC-V9-ZF33KE 7.13 8.74 12.55 17.15 19.75 25.50 MC-V9-ZF33KE 6.27 6.74 7.73 8.83 9.43 10.70
MC-S9-ZF34K5 6.72 8.26 11.85 16.10 18.50 MC-S9-ZF34K5 5.63 6.05 7.07 8.35 9.09
MC-V6-ZF41K5 8.64 10.60 15.40 21.40 24.80 32.60 MC-V6-ZF41K5 6.99 7.54 8.74 10.05 10.80 12.40
MC-V6-ZF49K5 10.20 12.50 18.05 24.80 28.70 MC-V6-ZF49K5 8.39 8.93 10.30 12.10 13.10
Digital Medium Temperature Models
MC-M8-ZBD30KE 4.97 6.93 8.04 10.50 MC-M8-ZBD30KE 2.99 3.40 3.60 4.04
MC-M9-ZBD45KE 7.11 9.83 11.35 14.60 MC-M9-ZBD45KE 4.53 5.20 5.57 6.36
MC-V6-ZBDT60KE 10.40 14.90 17.55 23.60 MC-V6-ZBDT60KE 6.30 6.74 6.96 7.49
MC-V6-ZBDT90KE 14.10 20.40 24.10 32.50 MC-V6-ZBDT90KE 9.56 10.35 10.75 11.85

Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K


* Conditions: EN13215: Suction Superheat 10K
** Single Phase only
Preliminary Data

143 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R407C Evaporating Temperature (°C) R407C Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
MC-D8-ZB15KE 1.80* 2.98 3.61 5.05 MC-D8-ZB15KE 1.55* 1.63 1.67 1.78
MC-H8-ZB15KE 1.93* 3.20 3.91 5.56 MC-H8-ZB15KE 1.55* 1.58 1.59 1.65
MC-D8-ZB19KE 2.02* 3.20* 4.01 5.68 MC-D8-ZB19KE 1.72* 1.88* 1.99 2.22
MC-H8-ZB19KE 2.15* 3.52 4.34 6.30 MC-H8-ZB19KE 1.71* 1.81 1.87 1.99
MC-K9-ZB19KE 2.15* 3.51 4.33 6.28 MC-K9-ZB19KE 1.70* 1.80 1.86 1.98
MC-H8-ZB21KE 2.85* 4.56 5.51 7.75 MC-H8-ZB21KE 2.13* 2.29 2.38 2.58
MC-K9-ZB21KE 2.84* 4.55 5.50 7.72 MC-K9-ZB21KE 2.12* 2.29 2.38 2.58
MC-D8-ZB21KE 2.63* 4.04* 4.86* 6.79 MC-D8-ZB21KE 2.24* 2.49* 2.64* 3.03
MC-H8-ZB26KE 3.26* 5.08* 6.26 8.74 MC-H8-ZB26KE 2.53* 2.74* 2.87 3.16
MC-K9-ZB26KE 3.25* 5.06* 6.24 8.71 MC-K9-ZB26KE 2.52* 2.74* 2.87 3.17
MC-H8-ZB30KE 4.02* 5.89* 7.14 9.74 MC-H8-ZB30KE 2.96* 3.37* 3.59 4.04
MC-P8-ZB30KE 4.19* 6.31 7.53 10.45 MC-P8-ZB30KE 2.79* 3.13 3.27 3.61
MC-M8-ZB30KE 4.17* 6.15* 7.48 10.35 MC-M8-ZB30KE 2.83* 3.16* 3.33 3.68
MC-H8-ZB38KE 7.03* 8.36* 11.40 MC-H8-ZB38KE 4.27* 4.54* 5.26
MC-P8-ZB38KE 4.93* 7.52* 9.14 12.45 MC-P8-ZB38KE 3.55* 3.85* 4.09 4.61
MC-M8-ZB38KE 4.89* 7.45* 9.06 12.30 MC-M8-ZB38KE 3.60* 3.92* 4.16 4.71
MC-M8-ZB42KE** 5.29* 7.90* 9.44* 13.00 MC-M8-ZB42KE** 4.52* 4.93* 5.14* 5.64
MC-R7-ZB42KE** 5.65* 8.75 10.50 14.65 MC-R7-ZB42KE** 4.33* 4.57 4.66 4.83
MC-M8-ZB45KE 5.38* 8.17* 9.83* 13.75 MC-M8-ZB45KE 4.31* 4.78* 5.09* 5.89
MC-R7-ZB45KE 5.80* 9.14 11.05 15.50 MC-R7-ZB45KE 4.12* 4.45 4.65 5.14
MC-M9-ZB45KE 5.63* 8.65* 10.65 14.80 MC-M9-ZB45KE 4.21* 4.58* 4.85 5.45
MC-R7-ZB50KE 5.90* 10.00 12.25 17.10 MC-R7-ZB50KE 5.05* 5.48 5.69 6.31
MC-S9-ZB50KE 6.32* 10.45 12.75 17.75 MC-S9-ZB50KE 4.86* 5.21 5.40 5.96
MC-S9-ZB66KE 13.30 15.90 22.00 MC-S9-ZB66KE 6.72 7.07 7.90
MC-V9-ZB66KE 8.98* 13.75 16.50 23.00 MC-V9-ZB66KE 5.83* 6.37 6.65 7.32
MC-V9-ZB76KE 9.95* 15.55 18.70 26.00 MC-V9-ZB76KE 6.92* 7.65 8.05 9.05
MC-V6-ZB76KE 10.40* 16.25 19.65 27.60 MC-V6-ZB76KE 6.91* 7.45 7.74 8.45
MC-W9-ZB114KE 13.55* 22.20 26.90 37.70 MC-W9-ZB114KE 10.70* 11.85 12.50 14.00

Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
** Single Phase only
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 144


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R134a Evaporating Temperature (°C) R134a Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Medium Temperature Models
MC-D8-ZB15KE 1.40 2.19 2.69 3.89 MC-D8-ZB15KE 0.99 1.04 1.08 1.16
MC-H8-ZB15KE 1.43 2.26 2.79 4.09 MC-H8-ZB15KE 1.08 1.11 1.14 1.20
MC-D8-ZB19KE 1.60 2.50 3.06 4.40 MC-D8-ZB19KE 1.13 1.20 1.25 1.36
MC-H8-ZB19KE 1.64 2.59 3.19 4.65 MC-H8-ZB19KE 1.21 1.26 1.29 1.36
MC-K9-ZB19KE 1.64 2.59 3.20 4.67 MC-K9-ZB19KE 1.19 1.24 1.27 1.34
MC-H8-ZB21KE 2.05 3.21 3.95 5.72 MC-H8-ZB21KE 1.46 1.53 1.58 1.69
MC-K9-ZB21KE 2.05 3.22 3.96 5.75 MC-K9-ZB21KE 1.44 1.51 1.55 1.66
MC-D8-ZB21KE 1.87* 3.07 3.74 5.33 MC-D8-ZB21KE 1.41* 1.52 1.59 1.76
MC-H8-ZB26KE 2.34 3.67 4.50 6.49 MC-H8-ZB26KE 1.66 1.75 1.81 1.95
MC-K9-ZB26KE 2.35 3.68 4.51 6.52 MC-K9-ZB26KE 1.64 1.72 1.78 1.92
MC-H8-ZB30KE 2.72 4.24 5.18 7.43 MC-H8-ZB30KE 1.92 2.04 2.12 2.32
MC-M8-ZB30KE 2.77 4.35 5.34 7.74 MC-M8-ZB30KE 1.86 1.95 2.02 2.17
MC-P8-ZB30KE 2.79 4.38 5.39 7.84 MC-P8-ZB30KE 1.83 1.91 1.97 2.11
MC-H8-ZB38KE 3.10* 5.08 6.18 8.77 MC-H8-ZB38KE 2.45* 2.66 2.78 3.09
MC-M8-ZB38KE 3.36 5.25 6.42 9.23 MC-M8-ZB38KE 2.37 2.52 2.61 2.85
MC-P8-ZB38KE 3.39 5.30 6.50 9.38 MC-P8-ZB38KE 2.32 2.46 2.54 2.76
MC-M8-ZB42KE** 3.81 5.87 7.12 10.10 MC-M8-ZB42KE** 2.76 2.91 2.97 3.09
MC-R7-ZB42KE** 3.93 6.11 7.46 10.75 MC-R7-ZB42KE** 2.83 2.89 2.90 2.90
MC-M8-ZB45KE 4.04 6.21 7.55 10.70 MC-M8-ZB45KE 2.74 2.96 3.09 3.42
MC-M9-ZB45KE 4.13 6.39 7.79 11.15 MC-M9-ZB45KE 2.81 2.99 3.10 3.36
MC-R7-ZB45KE 4.18 6.49 7.93 11.45 MC-R7-ZB45KE 2.83 2.99 3.08 3.30
MC-R7-ZB50KE 4.72 7.33 8.94 12.75 MC-R7-ZB50KE 3.36 3.52 3.66 3.97
MC-S9-ZB50KE 4.77 7.45 9.12 13.10 MC-S9-ZB50KE 3.29 3.42 3.54 3.81
MC-S9-ZB66KE 6.09 9.35 11.40 16.35 MC-S9-ZB66KE 4.11 4.31 4.49 4.90
MC-V9-ZB66KE 6.16 9.50 11.60 16.70 MC-V9-ZB66KE 4.03 4.20 4.36 4.72
MC-V9-ZB76KE 6.98 10.75 13.10 18.80 MC-V9-ZB76KE 4.74 4.94 5.15 5.61
MC-V6-ZB76KE 7.12 11.05 13.55 19.60 MC-V6-ZB76KE 4.91 5.04 5.20 5.56
MC-V9-ZB95KE 8.25 13.25 16.15 22.90 MC-V9-ZB95KE 5.87 6.37 6.67 7.43
MC-V6-ZB95KE 8.58 13.80 16.90 24.20 MC-V6-ZB95KE 5.94 6.32 6.54 7.12
MC-V6-ZB114KE 9.85 16.05 19.75 28.40 MC-V6-ZB114KE 7.16 7.64 7.94 8.72
MC-W9-ZB114KE 9.91 16.15 19.90 28.70 MC-W9-ZB114KE 7.11 7.56 7.85 8.59
Digital Medium Temperature Models
MC-M8-ZBD30KE 2.91 4.47 5.39 7.60 MC-M8-ZBD30KE 1.78 2.01 2.12 2.37
MC-M9-ZBD45KE 3.93* 6.35 7.72 11.00 MC-M9-ZBD45KE 2.58* 2.95 3.13 3.53
MC-V6-ZBDT60KE 5.79 9.05 11.05 16.00 MC-V6-ZBDT60KE 3.87 4.13 4.26 4.59
MC-V6-ZBDT90KE 8.36 12.95 15.85 22.90 MC-V6-ZBDT90KE 5.23 5.71 5.96 6.55
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
** Single Phase only
Preliminary Data

145 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Ambient Temperature: 32°C

Cooling Capacity (kW) Power Input (kW)

R450A Evaporating Temperature (°C) R450A Evaporating Temperature (°C)

-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5

Medium Temperature Models

MC-D8-ZB15KE 1.17 1.91 2.38 3.50 MC-D8-ZB15KE 0.92 0.91 0.91 0.95

MC-H8-ZB15KE 1.21 1.99 2.48 3.70 MC-H8-ZB15KE 1.00 0.98 0.98 1.00

MC-D8-ZB19KE 1.36 2.18 2.70 3.96 MC-D8-ZB19KE 1.05 1.07 1.10 1.17

MC-H8-ZB19KE 1.40 2.26 2.81 4.18 MC-H8-ZB19KE 1.13 1.14 1.15 1.20

MC-K9-ZB19KE 1.40 2.27 2.82 4.20 MC-K9-ZB19KE 1.11 1.12 1.13 1.18

MC-D8-ZB21KE 1.62* 2.76 3.39 4.88 MC-D8-ZB21KE 1.26* 1.32 1.35 1.47

MC-H8-ZB21KE 1.80 2.89 3.58 5.25 MC-H8-ZB21KE 1.32 1.35 1.37 1.44

MC-K9-ZB21KE 1.80 2.90 3.59 5.28 MC-K9-ZB21KE 1.30 1.32 1.34 1.41

MC-H8-ZB26KE 2.07 3.30 4.06 5.96 MC-H8-ZB26KE 1.54 1.57 1.60 1.70

MC-K9-ZB26KE 2.08 3.31 4.08 6.00 MC-K9-ZB26KE 1.52 1.54 1.57 1.67

MC-H8-ZB30KE 2.39 3.84 4.73 6.87 MC-H8-ZB30KE 1.75 1.80 1.83 1.95

MC-M8-ZB30KE 2.44 3.94 4.86 7.13 MC-M8-ZB30KE 1.70 1.73 1.75 1.84

MC-P8-ZB30KE 2.47 3.98 4.92 7.23 MC-P8-ZB30KE 1.66 1.69 1.71 1.79

MC-H8-ZB38KE 2.73* 4.62 5.66 8.18 MC-H8-ZB38KE 2.19* 2.29 2.36 2.57

MC-M8-ZB38KE 2.99 4.77 5.88 8.58 MC-M8-ZB38KE 2.13 2.19 2.24 2.40

MC-P8-ZB38KE 3.02 4.83 5.96 8.74 MC-P8-ZB38KE 2.08 2.13 2.18 2.32

MC-H8-ZB38KE 2.73* 4.62 5.66 8.18 MC-H8-ZB38KE 2.19* 2.29 2.36 2.57

MC-M8-ZB42KE** 3.33 5.33 6.53 9.43 MC-M8-ZB42KE** 2.35 2.45 2.51 2.69

MC-R7-ZB42KE** 3.44 5.54 6.83 10.00 MC-R7-ZB42KE** 2.48 2.54 2.58 2.70

MC-M8-ZB45KE 3.48 5.52 6.77 9.80 MC-M8-ZB45KE 2.45 2.53 2.60 2.79

MC-M9-ZB45KE 3.54 5.66 6.97 10.15 MC-M9-ZB45KE 2.55 2.61 2.66 2.81

MC-R7-ZB45KE 3.59 5.75 7.11 10.45 MC-R7-ZB45KE 2.58 2.62 2.66 2.78

MC-R7-ZB58KE 4.53 7.15 8.77 12.65 MC-R7-ZB58KE 3.32 3.61 3.77 4.13

MC-S9-ZB58KE 4.59 7.27 8.94 13.00 MC-S9-ZB58KE 3.26 3.53 3.67 3.99

MC-S9-ZB66KE 5.11 8.08 9.91 14.35 MC-S9-ZB66KE 3.64 3.94 4.10 4.50

MC-V9-ZB66KE 5.16 8.18 10.05 14.60 MC-V9-ZB66KE 3.59 3.87 4.02 4.38

MC-V6-ZB76KE 6.04 9.67 11.90 17.45 MC-V6-ZB76KE 4.37 4.70 4.87 5.23

MC-V9-ZB76KE 5.91 9.44 11.60 16.85 MC-V9-ZB76KE 4.14 4.53 4.74 5.18

MC-V6-ZB95KE 7.33 11.75 14.50 21.30 MC-V6-ZB95KE 5.39 5.73 6.00 6.68

MC-V9-ZB95KE 7.09 11.30 13.95 20.30 MC-V9-ZB95KE 5.26 5.66 5.97 6.79

MC-V6-ZB114KE 8.43 13.75 17.00 24.80 MC-V6-ZB114KE 6.52 7.02 7.34 8.12

MC-W9-ZB114KE 8.47 13.80 17.10 25.00 MC-W9-ZB114KE 6.49 6.97 7.29 8.04

Digital Medium Temperature Models

MC-M8-ZBD30KE 2.48 3.96 4.86 7.07 MC-M8-ZBD30KE 1.54 1.69 1.76 1.96

MC-M9-ZBD45KE 3.60 5.76 7.06 10.20 MC-M9-ZBD45KE 2.32 2.56 2.70 3.04

MC-V6-ZBDT60KE 5.04 8.12 10.05 14.80 MC-V6-ZBDT60KE 3.49 3.63 3.70 3.95

MC-V6-ZBDT90KE 7.25 11.60 14.30 21.00 MC-V6-ZBDT90KE 4.79 5.06 5.22 5.67

Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
** Single Phase only
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 146


Capacity data
Ambient Temperature: 32°C

Cooling Capacity (kW) Power Input (kW)

R513A Evaporating Temperature (°C) R513A Evaporating Temperature (°C)

-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5

Medium Temperature Models

MC-D8-ZB15KE 1.42 2.26 2.76 3.95 MC-D8-ZB15KE 1.08 1.08 1.09 1.13

MC-H8-ZB15KE 1.48 2.37 2.91 4.23 MC-H8-ZB15KE 1.15 1.14 1.13 1.15

MC-D8-ZB19KE 1.65 2.57 3.13 4.47 MC-D8-ZB19KE 1.24 1.29 1.32 1.41

MC-H8-ZB19KE 1.71 2.69 3.30 4.80 MC-H8-ZB19KE 1.30 1.33 1.34 1.40

MC-K9-ZB19KE 1.72 2.70 3.31 4.83 MC-K9-ZB19KE 1.28 1.30 1.32 1.38

MC-D8-ZB21KE 1.92* 3.20 3.86 5.41 MC-D8-ZB21KE 1.49* 1.60 1.66 1.79

MC-H8-ZB21KE 2.18 3.41 4.15 5.95 MC-H8-ZB21KE 1.54 1.59 1.62 1.70

MC-K9-ZB21KE 2.19 3.43 4.18 5.99 MC-K9-ZB21KE 1.51 1.56 1.59 1.67

MC-H8-ZB26KE 2.51 3.87 4.74 6.78 MC-H8-ZB26KE 1.80 1.86 1.91 2.03

MC-K9-ZB26KE 2.52 3.89 4.77 6.84 MC-K9-ZB26KE 1.77 1.83 1.88 1.99

MC-H8-ZB30KE 2.67* 4.47 5.45 7.77 MC-H8-ZB30KE 2.05* 2.15 2.21 2.37

MC-M8-ZB30KE 2.96 4.63 5.67 8.17 MC-M8-ZB30KE 1.99 2.05 2.09 2.21

MC-P8-ZB30KE 2.99 4.69 5.76 8.33 MC-P8-ZB30KE 1.95 2.00 2.03 2.13

MC-M8-ZB38KE 3.35* 5.60 6.84 9.74 MC-M8-ZB38KE 2.49* 2.63 2.70 2.90

MC-P8-ZB38KE 3.66 5.69 6.96 9.97 MC-P8-ZB38KE 2.45 2.56 2.62 2.79

MC-H8-ZB38KE 3.23* 5.37 6.52 9.15 MC-H8-ZB38KE 2.58* 2.78 2.88 3.15

MC-M8-ZB42KE** 3.74* 6.24 7.56 10.65 MC-M8-ZB42KE** 2.78* 2.96 3.05 3.29

MC-R7-ZB42KE** 4.21 6.56 8.01 11.50 MC-R7-ZB42KE** 2.88 2.98 3.04 3.19

MC-M8-ZB45KE 3.87* 6.45 7.83 11.05 MC-M8-ZB45KE 2.88* 3.07 3.16 3.41

MC-M9-ZB45KE 4.29 6.65 8.12 11.55 MC-M9-ZB45KE 2.98 3.10 3.17 3.36

MC-R7-ZB45KE 4.37 6.80 8.32 11.95 MC-R7-ZB45KE 2.99 3.08 3.14 3.29

MC-R7-ZB58KE 5.45 8.41 10.20 14.35 MC-R7-ZB58KE 3.93 4.13 4.27 4.65

MC-S9-ZB58KE 5.55 8.59 10.45 14.85 MC-S9-ZB58KE 3.85 4.01 4.13 4.45

MC-S9-ZB66KE 6.17 9.55 11.60 16.40 MC-S9-ZB66KE 4.32 4.53 4.67 5.07

MC-V9-ZB66KE 6.26 9.70 11.80 16.80 MC-V9-ZB66KE 4.26 4.43 4.55 4.90

MC-V6-ZB76KE 7.36 11.50 14.00 20.20 MC-V6-ZB76KE 5.11 5.33 5.46 5.79

MC-V9-ZB76KE 7.17 11.15 13.55 19.25 MC-V9-ZB76KE 4.93 5.23 5.41 5.87

MC-V6-ZB95KE 8.90 14.00 17.05 24.30 MC-V6-ZB95KE 6.35 6.71 6.91 7.41

MC-V9-ZB95KE 8.57 13.35 16.20 22.80 MC-V9-ZB95KE 6.28 6.77 7.06 7.76

MC-V6-ZB114KE 10.10 16.30 19.85 28.10 MC-V6-ZB114KE 7.76 8.23 8.49 9.12

MC-W9-ZB114KE 10.15 16.40 20.00 28.30 MC-W9-ZB114KE 7.72 8.16 8.40 9.00

Digital Medium Temperature Models

MC-M8-ZBD30KE 3.02 4.67 5.67 8.07 MC-M8-ZBD30KE 1.79 1.99 2.08 2.32

MC-M9-ZBD45KE 4.38 6.75 8.19 11.60 MC-M9-ZBD45KE 2.70 3.02 3.20 3.61

MC-V6-ZBDT60KE 6.15 9.64 11.85 17.15 MC-V6-ZBDT60KE 3.99 4.18 4.28 4.58

MC-V6-ZBDT90KE 8.82 13.70 16.75 24.00 MC-V6-ZBDT90KE 5.56 5.95 6.16 6.70

Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
** Single Phase only
Preliminary Data

147 GPC-EN-2024 REFRIGERATION APPLICATIONS


Copeland scroll digital receiver unit HLR

Copeland scroll digital receiver units are the perfect choice for
remote condenser systems.

These scroll digital receiver units are an innovative offering by


Copeland for food service and retail businesses. Their compact
design and the power of digital scroll continuous capacity
modulation allow for optimized environmental integration at
highest system efficiency.
Digital receiver unit HLR
Eight models with single or tandem compressors cover the
need of medium temperature refrigeration capacities in various
applications. The continuous capacity modulation always
provides the right performance, especially for systems with
multiple evaporators and variable loads. The remote condenser
concept allows for optimal building integration.

Digital receiver unit HLR line-up

Single Models

Tandem Models

Capacity (kW)
R448A/R449A, EN13215 0 10 20 30 40

Features and benefits Maximum allowable pressures (PS)

• Standard equipment: digital scroll compressor, liquid • Low Side PS 22.5 bar (g)
receiver, liquid line with filter drier and sight glass, HP/LP • High Side PS = 28/32 bar (g)
switch, complete electrical box including controller with
overload protection and communication interface
• Continuous capacity modulation 10-100 % (Single) or
5-100 % (Tandem)
• Precise suction pressure control
• Maximum system flexibility by free choice of third party
condensers
• Excellent energy efficiency
• High reliability
• Easy and quick installation
• Suitable for multiple refrigerants: R407A/F, R448A/R449A,
R404A, R134a, R450A and R513A

GPC-EN-2024 REFRIGERATION APPLICATIONS 148


Technical overview

Version/Code

Locked Rotor
Current (A)

Current (A)
Receiver Capacity (l)
Displacement (m3/h)

Operating
Maximum
Sound Pressure

Motor
Net Weight (kg)
Diameter (inch)
Suction Line
@1 m -

Liquid Line
Width/

Diameter
dB(A)***

(inch)
Depth/
Models
Height
(mm)
Without With
3 Ph** 3 Ph** 3 Ph** Sound Sound
Shell Shell

Single Compressor Unit Models


HLR-13-ZBD30KCE 11.7 13 7⁄8 5⁄8 719/412/712 68 TFD 8 52 59 49
HLR-13-ZBD45KCE 17.1 13 7⁄8 5⁄8 719/412/712 70 TFD 12 74 61 51
HLR-13-ZBD58KCE 22.1 13 11⁄8 7⁄8 723/439/685 95 TFD 16 95 65 55
HLR-13-ZBD76KCE 28.8 13 11⁄8 7⁄8 723/439/742 93 TFD 20 118 66 56
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 23.4 31 13⁄8 7⁄8 956/577/917 122 TFD 8 + 10 52 + 49 59 49
HLR-31-ZBDT90KCE 34.1 31 13⁄8 7⁄8 956/577/917 125 TFD 12 + 13 2 x 74 64 54
HLR-31-ZBDT114KCE 44.2 31 15⁄8 7⁄8 954/559/940 142 TFD 2 x 16 2 x 95 67 -
HLR-31-ZBDT152K5E 57.6 31 15⁄8 7⁄8 954/592/945 168 TFD 24 + 20 2 x 118 66 -
** 3 Ph: 380-420V/ 50Hz
*** @ 1m: sound pressure level at 1m distance from the compressor, free field condition

149 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Condensing Temperature: 40°C
Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 4.59 7.29 8.98 13.10 HLR-13-ZBD30KCE 2.75 2.77 2.79 2.82
HLR-13-ZBD45KCE 6.36 10.10 12.50 18.25 HLR-13-ZBD45KCE 3.81 3.83 3.87 3.91
HLR-13-ZBD58KCE 7.27* 13.05 16.30 24.10 HLR-13-ZBD58KCE 5.13* 5.30 5.35 5.39
HLR-13-ZBD76KCE 9.93* 17.25 21.50 31.70 HLR-13-ZBD76KCE 6.57* 6.88 6.97 7.09
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 8.79* 14.55 17.90 26.10 HLR-31-ZBDT60KCE 5.43* 5.49 5.55 5.63
HLR-31-ZBDT90KCE 12.35* 20.30 24.90 36.30 HLR-31-ZBDT90KCE 7.75* 7.82 7.84 7.81
HLR-31-ZBDT114KCE 16.50* 26.80 32.80 47.50 HLR-31-ZBDT116KE 9.61* 10.05 10.30 10.75
HLR-31-ZBDT152K5E 22.30 36.40 45.20 65.20 HLR-31-ZBDT152KE 13.70 13.90 14.40 15.00
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R407F R407F
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 4.66* 7.27 8.82 12.75 HLR-13-ZBD30KCE 2.49* 2.82 2.93 3.12
HLR-13-ZBD45KCE 6.41* 10.75 13.15 18.85 HLR-13-ZBD45KCE 3.68* 4.09 4.29 4.62
HLR-13-ZBD58KCE 7.46* 14.05 17.55 25.80 HLR-13-ZBD58KCE 5.37* 5.51 5.54 5.60
HLR-13-ZBD76KCE 10.45* 18.80 23.30 34.20 HLR-13-ZBD76KCE 6.85* 7.14 7.22 7.37
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 8.85* 14.45 17.70 25.70 HLR-31-ZBDT60KCE 5.43* 5.73 5.83 5.96
HLR-31-ZBDT90KCE 12.40* 21.20 26.10 37.90 HLR-31-ZBDT90KCE 7.80* 8.35 8.53 8.82
HLR-31-ZBDT114KCE 17.00* 27.60 33.90 49.20 HLR-31-ZBDT114KCE 10.15* 10.40 10.50 10.65
HLR-31-ZBDT152K5E 22.40* 38.90 48.20 69.20 HLR-31-ZBDT152K5E 14.35* 14.60 15.10 15.80
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R448A R448A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 4.63 7.21 8.81 12.80 HLR-13-ZBD30KCE 2.42 2.69 2.83 3.13
HLR-13-ZBD45KCE 6.77 10.60 12.95 18.70 HLR-13-ZBD45KCE 3.42 3.82 4.00 4.41
HLR-13-ZBD58KCE 8.59* 13.70 16.85 24.4 HLR-13-ZBD58KCE 5.26* 5.24 5.28 5.38
HLR-13-ZBD76KCE 11.10* 18.70 22.90 33.00 HLR-13-ZBD76KCE 7.02* 7.10 7.17 7.37
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 9.15 14.35 17.55 25.40 HLR-31-ZBDT60KCE 5.16 5.43 5.57 5.91
HLR-31-ZBDT90KCE 13.40 21.10 25.70 37.20 HLR-31-ZBDT90KCE 7.30 7.69 7.89 8.34
HLR-31-ZBDT114KCE 17.55 27.00 33.00 47.90 HLR-31-ZBDT114KCE 8.51 9.54 10.20 11.75
HLR-31-ZBDT152K5E - 37.40 45.60 65.90 HLR-31-ZBDT152K5E - 13.55 13.70 14.15
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 150


Capacity data
Condensing Temperature: 40°C
Cooling Capacity (kW) Power Input (kW)
R449A R449A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 4.63 7.21 8.81 12.80 HLR-13-ZBD30KCE 2.42 2.69 2.83 3.13
HLR-13-ZBD45KCE 6.77 10.60 12.95 18.70 HLR-13-ZBD45KCE 3.42 3.82 4.00 4.41
HLR-13-ZBD58KCE 7.86* 13.75 16.90 24.40 HLR-13-ZBD58KCE 5.26* 5.24 5.28 5.38
HLR-13-ZBD76KCE 11.05* 18.70 22.90 33.00 HLR-13-ZBD76KCE 7.02* 7.10 7.17 7.37
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 9.15 14.35 17.55 25.40 HLR-31-ZBDT60KCE 5.16 5.43 5.57 5.91
HLR-31-ZBDT90KCE 13.40 21.10 25.70 37.20 HLR-31-ZBDT90KCE 7.30 7.69 7.89 8.34
HLR-31-ZBDT114KCE 17.55 27.00 33.00 47.90 HLR-31-ZBDT114KCE 8.51 9.54 10.20 11.75
HLR-31-ZBDT152K5E - 37.40 45.60 65.90 HLR-31-ZBDT152K5E - 13.55 13.70 14.15
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

Condensing Temperature: 45°C


Cooling Capacity (kW) Power Input (kW)
R404A Evaporating Temperature (°C) R404A Evaporating Temperature (°C)
-45 -35 -30 -20 -10 -5 +5 -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 5.14 7.57 9.07 12.70 HLR-13-ZBD30KCE 2.65 2.87 2.96 3.20
HLR-13-ZBD45KCE 7.55 11.15 13.35 18.80 HLR-13-ZBD45KCE 3.84 4.19 4.37 4.75
HLR-13-ZBD58KCE 9.53 14.65 17.65 24.80 HLR-13-ZBD58KCE 5.66 5.70 5.76 5.81
HLR-13-ZBD76KCE 12.90 19.35 23.20 32.70 HLR-13-ZBD76KCE 7.26 7.42 7.50 7.64
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 10.35 15.20 18.20 25.50 HLR-31-ZBDT60KCE 5.29 5.74 5.93 6.40
HLR-31-ZBDT90KCE 14.95 22.10 26.50 37.40 HLR-31-ZBDT90KCE 8.16 8.49 8.64 8.95
HLR-31-ZBDT114KCE 19.55 28.60 34.20 47.90 HLR-31-ZBDT114KCE 9.87 10.75 11.10 11.65
HLR-31-ZBDT152K5E 26.40 39.60 47.50 66.80 HLR-31-ZBDT152K5E 14.75 15.10 15.30 15.55
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R407C R407C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 4.24* 6.61 8.06 11.80 HLR-13-ZBD30KCE 2.54* 2.66 2.67 2.70
HLR-13-ZBD45KCE 5.83* 9.59 11.85 17.40 HLR-13-ZBD45KCE 3.63* 3.65 3.67 3.72
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 8.47* 13.20 16.10 23.60 HLR-31-ZBDT60KCE 5.08* 5.31 5.35 5.41
HLR-31-ZBDT90KCE 11.65* 19.20 23.70 34.80 HLR-31-ZBDT90KCE 7.25* 7.30 7.35 7.45
HLR-31-ZBDT114KCE 13.25* 22.50 28.20 42.30 HLR-31-ZBDT114KCE 9.29* 9.64 9.74 9.88
HLR-31-ZBDT152K5E 21.10* 34.20 41.90 61.20 HLR-31-ZBDT152K5E 12.95* 13.20 13.25 13.40
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
*Conditions: Suction Superheat 10K, Subcooling 0K

151 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Condensing Temperature: 40°C
Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 2.69* 4.46 5.44 7.94 HLR-13-ZBD30KCE 1.59* 1.78 1.85 2.02
HLR-13-ZBD45KCE 3.82* 6.40 7.91 11.80 HLR-13-ZBD45KCE 2.25* 2.53 2.63 2.86
HLR-13-ZBD58KCE 5.16 8.27 10.25 15.25 HLR-13-ZBD58KCE 3.38 3.37 3.42 3.51
HLR-13-ZBD76KCE 6.86 10.80 13.45 20.00 HLR-13-ZBD76KCE 4.42 4.42 4.48 4.59
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 5.22* 8.78 10.80 16.00 HLR-31-ZBDT60KCE 3.31* 3.52 3.61 3.80
HLR-31-ZBDT90KCE 7.62* 12.80 15.95 23.90 HLR-31-ZBDT90KCE 4.67* 4.99 5.12 5.39
HLR-31-ZBDT114KCE 9.49* 16.15 20.10 30.20 HLR-31-ZBDT114KCE 6.79* 6.88 6.93 7.04
HLR-31-ZBDT152K5E 13.85 21.90 27.20 40.40 HLR-31-ZBDT152K5E 9.25 9.23 9.35 9.59
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R450A R450A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 2.20* 3.89 4.85 7.29 HLR-13-ZBD30KCE 1.38* 1.49 1.53 1.67
HLR-13-ZBD45KCE 3.24* 5.74 7.16 10.80 HLR-13-ZBD45KCE 2.01* 2.17 2.26 2.48
HLR-13-ZBD58KCE 4.57 7.41 9.17 13.55 HLR-13-ZBD58KCE 2.47 2.65 2.74 2.87
HLR-13-ZBD76KCE 6.20 9.80 12.05 17.80 HLR-13-ZBD76KCE 3.18 3.44 3.56 3.79
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 4.36* 7.76 9.70 14.65 HLR-31-ZBDT60KCE 2.96* 3.03 3.06 3.20
HLR-31-ZBDT90KCE 6.42* 11.35 14.20 21.50 HLR-31-ZBDT90KCE 4.28* 4.40 4.47 4.69
HLR-31-ZBDT114KCE 7.92* 13.95 17.40 26.10 HLR-31-ZBDT114KCE 5.16* 5.56 5.74 6.09
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

Condensing Temperature: 40°C


Cooling Capacity (kW) Power Input (kW)
R513A R513A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Single Compressor Unit Models
HLR-13-ZBD30KCE 2.69* 4.66 5.76 8.55 HLR-13-ZBD30KCE 1.62* 1.76 1.81 1.96
HLR-13-ZBD45KCE 3.95* 6.85 8.50 12.70 HLR-13-ZBD45KCE 2.36* 2.57 2.67 2.92
HLR-13-ZBD58KCE 5.58 8.87 10.90 15.90 HLR-13-ZBD58KCE 3.07 3.25 3.33 3.44
HLR-13-ZBD76KCE 7.58 11.80 14.45 21.00 HLR-13-ZBD76KCE 3.97 4.22 4.34 4.55
Tandem Compressor Unit Models
HLR-31-ZBDT60KCE 5.32* 9.27 11.55 17.20 HLR-31-ZBDT60KCE 3.47* 3.58 3.61 3.76
HLR-31-ZBDT90KCE 7.81* 13.60 16.90 25.30 HLR-31-ZBDT90KCE 5.01* 5.20 5.28 5.51
HLR-31-ZBDT114KCE 9.89* 17.05 21.10 31.30 HLR-31-ZBDT114KCE 6.06* 6.57 6.78 7.16
HLR-31-ZBDT152K5E 14.55 23.30 28.80 42.40 HLR-31-ZBDT152K5E 9.09 9.56 9.66 9.77
Conditions: Suction Gas Return 20°C / Subcooling 0K For detailed capacity data please refer to Copeland Select software
*Conditions: Suction Superheat 10K, Subcooling 0K
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 152


153 GPC-EN-2024 REFRIGERATION APPLICATIONS
Semi-hermetic refrigeration units with K/L compressors

Copeland air-cooled indoor refrigeration units for medium


temperature and low temperature applications.

Long-term engineering and manufacturing experience has led to


these refrigeration units with reed valve technology compressors.
Their excellent quality and reliability is traditionally well known in
the refrigeration industry.

This series of refrigeration units is equipped with single fan


or twin fans which allows for very compact dimensions. The
wide range of models offers solutions for most applications
including operation in extreme conditions like high evaporation
temperatures and high ambient temperatures.

Semi-hermetic refrigeration unit K/L


compressors

Semi-hermetic K & L refrigeration units line-up

Medium temperature models

Capacity (kW)
R448A/R449A, EN13215 0 1 2 3 4 5 6 7 8 9 10

Low temperature models

Capacity (kW)
R448A/R449A, EN13215 0 1 2 3 4

Features and benefits Maximum allowable pressures (PS)

• Standard equipment: compressor, condenser with thermally • Low Side PS 22.5 bar (g)
protected fan(s), discharge line with flexible pipe loop or • High Side PS = 28 bar (g)
vibration absorber, liquid receiver with shut-off-valve, HP/LP
switch with automatic reset
• Suitable for a broad range of refrigerants: R407A/F, R404A
and R134a
• Wide range of quality accessories
• Proven reliability

GPC-EN-2024 REFRIGERATION APPLICATIONS 154


Technical overview

Receiver Capacity

@10m - dB(A)***
Net Weight (kg)

Sound Pressure
Total Fan Motor

Diameter (inch)

Diameter (inch)
Number of fans
Displacement

Suction Line
Maximum

Liquid Line
Power (W)
Motor Version/ Locked Rotor
Operating

(m3/h)
Width/Depth/ Code Current (A)
Models

(l)
Height (mm) Current (A)

1 Ph* 3 Ph** 1 Ph* 3 Ph** 1 Ph* 3 Ph**


B8-KJ-10-B 3.3 3.3 1 85 5/8 1/2 560/570/396 57 CAG EWL 7 3 32 16 39
B8-KJ-7-B 3.3 3.3 1 85 5/8 1/2 560/570/396 57 CAG EWL 6 2 35 12
B8-KL-15-B 3.3 3.3 1 85 5/8 1/2 560/570/396 57 CAG EWL 8 3 43 19 39
B8-KM-5-B 3.3 3.3 1 85 5/8 1/2 560/570/396 56 CAG EWL 5 2 24 12 39
B8-KM-7-B 3.3 3.3 1 85 1/2 1/2 560/570/396 57 CAG EWL 6 2 35 12
B8-KSJ-10-B 3.3 3.3 1 85 5/8 1/2 560/570/396 58 CAG EWL 7 3 32 16
D8-KSJ-15-B 3.9 3.9 1 110 7/8 1/2 560/570/446 62 CAG EWL 9 3 43 19 45
D8-KSL-20-B 3.9 3.9 1 110 5/8 1/2 560/570/446 60 EWL 5 23
D8-LE-20-B 3.9 3.9 1 110 5/8 1/2 560/715/446 96 EWL 6 38
D8-LF-20-B 3.9 3.9 1 110 5/8 1/2 560/715/446 98 EWL 6 38
H8-KSL-20-B 7.9 7.9 1 235 5/8 1/2 735/680/533 60 EWL 5 23
H8-LE-20-B 7.9 7.9 1 235 7/8 1/2 735/680/533 108 EWL 6 38
H8-LF-30-B 7.9 7.9 1 235 7/8 1/2 735/680/533 108 EWL 7 51 48
H8-LJ-20-B 7.9 7.9 1 235 7/8 1/2 735/680/533 103 EWL 6 38
H8-LJ-30-B 7.9 7.9 1 235 7/8 1/2 735/680/533 108 EWL 7 51 48
H8-LL-30-B 7.9 7.9 1 235 1 /8 1
1/2 735/680/533 110 EWL 7 53 48
H8-LL-40-B 7.9 7.9 1 235 1 1/8 1/2 735/680/533 112 EWL 10 59 48
K9-LL-30-B 7.9 7.9 2 220 1 1/8 1/2 950/640/454 134 EWL 7 53 47
P8-LF-30-B 7.9 7.9 2 220 1 /8 1
1/2 950/640/633 127 EWL 7 51 47
P8-LJ-30-B 7.9 7.9 2 220 7/8 1/2 950/640/633 127 EWL 7 51 47
P8-LL-40-B 7.9 7.9 2 220 1 /8 1
1/2 950/640/633 128 EWL 10 59 48
* 1ph: 230V/ 50Hz
** 3 Ph: 380-420V/ 50Hz
*** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
B8-KM-5-B 0.30* 0.60 1.09 1.72 B8-KM-5-B 0.53* 0.60 0.76 0.93
B8-KM-7-B 1.03 1.67 2.05 2.93 B8-KM-7-B 0.76 0.93 1.01 1.20
B8-KJ-7-B 0.51* 0.85 1.43 2.17 B8-KJ-7-B 0.65* 0.75 0.98 1.26
B8-KJ-10-B 1.43 2.26 2.73 B8-KJ-10-B 0.99 1.26 1.42
B8-KSJ-10-B 0.69* 1.10 1.77 2.62 B8-KSJ-10-B 0.83* 0.96 1.25 1.62
D8-KSJ-15-B 1.92 3.05 3.71 5.16 D8-KSJ-15-B 1.30 1.61 1.77 2.11
B8-KL-15-B 0.72* 1.20 2.01 B8-KL-15-B 0.89* 1.02 1.37
H8-LE-20-B 0.90* 1.64 2.93 4.62 5.62 7.94 H8-LE-20-B 1.31* 1.48 1.88 2.33 2.58 3.13
D8-LE-20-B 0.86* 1.56 2.73 4.21 5.07 D8-LE-20-B 1.17* 1.35 1.77 2.28 2.58
H8-LF-30-B 4.14 6.12 7.28 H8-LF-30-B 2.55 3.15 3.50
P8-LF-30-B 4.28 6.41 7.68 P8-LF-30-B 2.51 3.08 3.39
D8-LF-20-B 1.20* 2.08 3.51 5.25 D8-LF-20-B 1.50* 1.74 2.31 3.03
H8-LJ-30-B 4.74 6.88 8.12 H8-LJ-30-B 2.88 3.58 3.97
P8-LJ-30-B 4.93 7.26 8.63 P8-LJ-30-B 2.83 3.48 3.84
H8-LJ-20-B 1.53* 2.60 4.47 6.84 H8-LJ-20-B 1.79* 2.09 2.76 3.57
P8-LL-40-B 5.41 8.18 9.75 P8-LL-40-B 3.02 3.88 4.36
H8-LL-30-B 1.69* 2.98 5.10 7.68 H8-LL-30-B 1.96* 2.31 3.12 4.08
H8-LL-40-B 5.15 7.65 9.01 H8-LL-40-B 3.06 3.97 4.49
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary data
155 GPC-EN-2024 REFRIGERATION APPLICATIONS
Capacity data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R404A R404A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
B8-KM-7-B 0.28 0.60 0.80 1.29 1.89 2.24 3.00 B8-KM-7-B 0.44 0.60 0.68 0.85 1.01 1.10 1.26
B8-KM-5-B 0.29 0.62 0.82 1.30 B8-KM-5-B 0.45 0.58 0.65 0.79
B8-KJ-7-B 0.42 0.83 1.07 1.66 B8-KJ-7-B 0.62 0.79 0.88 1.09
B8-KJ-10-B 0.38 0.80 1.05 1.66 2.38 2.77 3.62 B8-KJ-10-B 0.55 0.77 0.88 1.12 1.38 1.52 1.81
D8-KSJ-15-B 0.58 1.11 1.43 2.24 3.24 3.82 D8-KSJ-15-B 0.71 0.97 1.12 1.43 1.75 1.91
B8-KSJ-10-B 0.58 1.05 1.34 B8-KSJ-10-B 0.80 1.02 1.15
B8-KL-15-B 0.68 1.21 1.53 2.26 B8-KL-15-B 0.87 1.12 1.27 1.64
D8-KSL-20-B 0.85 1.58 2.02 3.08 4.33 D8-KSL-20-B 0.97 1.34 1.54 2.01 2.55
H8-KSL-20-B 0.89 1.66 2.15 3.33 4.82 5.67 H8-KSL-20-B 1.10 1.46 1.66 2.09 2.56 2.81
H8-LE-20-B 1.33 1.88 3.20 4.83 5.77 7.84 H8-LE-20-B 1.24 1.44 1.85 2.30 2.53 3.01
D8-LE-20-B 1.24 1.74 2.91 4.26 5.00 D8-LE-20-B 1.10 1.30 1.73 2.23 2.50
H8-LF-30-B 0.95 2.05 2.73 4.35 6.30 7.39 H8-LF-30-B 1.33 1.85 2.13 2.68 3.28 3.59
D8-LF-20-B 1.65 2.21 3.50 D8-LF-20-B 1.49 1.77 2.38
P8-LF-30-B 0.98 2.14 2.87 4.66 6.90 8.19 11.10 P8-LF-30-B 1.33 1.85 2.11 2.64 3.16 3.43 3.99
H8-LJ-30-B 1.07 2.26 2.99 4.71 6.76 7.89 H8-LJ-30-B 1.40 2.02 2.35 3.04 3.77 4.15
H8-LJ-20-B 2.09 2.86 H8-LJ-20-B 1.82 2.15
P8-LJ-30-B 1.11 2.38 3.17 5.09 7.49 8.86 11.90 P8-LJ-30-B 1.40 2.02 2.34 3.00 3.64 3.96 4.59
H8-LL-30-B 1.22 2.73 3.63 5.71 H8-LL-30-B 1.49 2.23 2.65 3.61
K9-LL-30-B 1.23 2.73 3.64 5.73 K9-LL-30-B 1.48 2.22 2.63 3.59
P8-LL-40-B 1.43 2.92 3.87 6.20 9.12 10.80 P8-LL-40-B 1.72 2.39 2.75 3.56 4.49 4.99
H8-LL-40-B 1.37 2.75 3.61 5.65 8.07 9.39 H8-LL-40-B 1.72 2.40 2.78 3.67 4.72 5.32
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
B8-KJ-7-B 0.98 1.58 1.93 2.78 B8-KJ-7-B 0.65 0.78 0.85 1.01
B8-KSJ-10-B 1.20 1.92 2.36 3.39 B8-KSJ-10-B 0.77 0.94 1.03 1.22
B8-KL-15-B 1.38 2.16 2.63 3.70 B8-KL-15-B 0.92 1.16 1.28 1.54
D8-KSL-20-B 1.80 2.78 3.50 5.01 D8-KSL-20-B 1.10 1.38 1.50 1.81
H8-KSL-20-B 1.86 2.99 3.69 5.39 H8-KSL-20-B 1.22 1.46 1.59 1.84
D8-LF-20-B 2.21 3.56 4.37 6.20 D8-LF-20-B 1.34 1.72 1.92 2.32
H8-LJ-20-B 2.68 4.26 5.21 7.45 H8-LJ-20-B 1.80 2.17 2.37 2.82
H8-LL-30-B 3.22 5.23 6.43 9.21 H8-LL-30-B 2.08 2.64 2.96 3.69
H8-LSG-40-B 4.18 6.53 7.90 11.00 H8-LSG-40-B 2.52 3.24 3.65 4.56
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software

GPC-EN-2024 REFRIGERATION APPLICATIONS 156


Capacity data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R448A R448A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
B8-KM-7-B 0.40 0.58 1.06 1.72 2.12 B8-KM-7-B 0.53 0.59 0.74 0.92 1.01
B8-KJ-10-B 0.64 0.88 1.48 2.25 2.70 B8-KJ-10-B 0.63 0.73 0.97 1.24 1.38
B8-KJ-7-B 0.63 0.86 1.47 B8-KJ-7-B 0.66 0.76 0.98
B8-KSJ-10-B 0.95 1.24 1.94 B8-KSJ-10-B 0.89 1.01 1.31
D8-KSJ-15-B 0.90 1.19 1.96 3.00 3.63 D8-KSJ-15-B 0.87 0.99 1.26 1.58 1.74
B8-KL-15-B 0.80 1.12 1.93 B8-KL-15-B 0.81 0.96 1.32
D8-LE-20-B 1.12 1.61 2.78 4.25 5.09 D8-LE-20-B 0.96 1.15 1.56 2.05 2.33
H8-LE-20-B 1.19 1.70 3.01 4.71 5.71 H8-LE-20-B 1.10 1.28 1.68 2.11 2.35
P8-LF-30-B 1.87 2.54 4.22 6.43 7.73 P8-LF-30-B 1.68 1.95 2.50 3.06 3.35
D8-LF-20-B 1.60 2.20 3.67 D8-LF-20-B 1.54 1.80 2.40
H8-LF-30-B 1.82 2.47 4.07 6.11 7.31 H8-LF-30-B 1.68 1.97 2.54 3.14 3.47
H8-LJ-30-B 1.94 2.68 4.53 6.84 8.15 H8-LJ-30-B 1.82 2.12 2.79 3.55 3.98
P8-LJ-30-B 1.99 2.76 4.71 7.21 8.66 P8-LJ-30-B 1.81 2.10 2.74 3.46 3.84
H8-LL-40-B 2.47 3.33 5.43 8.09 H8-LL-40-B 2.11 2.46 3.29 4.33
H8-LL-30-B 2.45 3.33 5.47 H8-LL-30-B 1.90 2.25 3.06
K9-LL-30-B 2.44 3.32 5.45 K9-LL-30-B 1.88 2.24 3.05
P8-LL-40-B 2.55 3.46 5.72 8.65 10.40 P8-LL-40-B 2.09 2.43 3.22 4.17 4.73
H8-LSG-40-B 2.94 4.02 6.61 H8-LSG-40-B 2.61 3.14 4.39
K9-LSG-40-B 2.94 4.01 6.58 K9-LSG-40-B 2.59 3.13 4.38
M8E-LSG-40-B 3.05 4.18 6.96 M8E-LSG-40-B 2.56 3.08 4.28
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R449A R449A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
B8-KM-7-B 0.40 0.58 1.06 1.70 2.10 B8-KM-7-B 0.53 0.59 0.74 0.92 1.02
B8-KJ-10-B 0.64 0.88 1.46 2.22 2.67 B8-KJ-10-B 0.63 0.73 0.97 1.24 1.38
B8-KJ-7-B 0.62 0.86 1.46 B8-KJ-7-B 0.66 0.76 0.98
B8-KSJ-10-B 0.94 1.23 1.93 B8-KSJ-10-B 0.89 1.01 1.32
D8-KSJ-15-B 0.90 1.19 1.96 3.00 3.63 D8-KSJ-15-B 0.87 0.99 1.26 1.58 1.74
B8-KL-15-B 0.80 1.12 1.91 B8-KL-15-B 0.81 0.96 1.32
D8-KSL-20-B 1.22 1.64 2.72 4.11 4.90 D8-KSL-20-B 1.08 1.27 1.74 2.29 2.60
H8-KSL-20-B 1.26 1.70 2.89 4.47 5.41 H8-KSL-20-B 1.20 1.39 1.82 2.30 2.55
D8-LE-20-B 1.12 1.61 2.78 4.25 5.08 D8-LE-20-B 0.96 1.15 1.56 2.05 2.33
H8-LE-20-B 1.19 1.70 3.01 4.71 5.71 H8-LE-20-B 1.10 1.28 1.68 2.11 2.35
D8-LF-20-B 1.60 2.20 3.67 D8-LF-20-B 1.54 1.80 2.40
H8-LF-30-B 1.82 2.47 4.07 6.11 7.31 H8-LF-30-B 1.68 1.97 2.54 3.14 3.47
P8-LF-30-B 1.87 2.54 4.22 6.43 7.73 P8-LF-30-B 1.68 1.95 2.50 3.06 3.35
H8-LJ-30-B 1.95 2.70 4.55 6.89 8.25 H8-LJ-30-B 1.80 2.09 2.76 3.55 4.01
P8-LJ-30-B 2.01 2.79 4.75 7.28 8.78 P8-LJ-30-B 1.79 2.08 2.73 3.46 3.86
H8-LL-30-B 2.45 3.33 5.47 H8-LL-30-B 1.90 2.25 3.06
H8-LL-40-B 2.47 3.33 5.43 8.09 H8-LL-40-B 2.11 2.46 3.29 4.33
K9-LL-30-B 2.44 3.32 5.45 K9-LL-30-B 1.88 2.24 3.05
P8-LL-40-B 2.55 3.46 5.72 8.65 10.40 P8-LL-40-B 2.09 2.43 3.22 4.17 4.73
H8-LSG-40-B 2.94 4.02 6.61 H8-LSG-40-B 2.61 3.14 4.39
K9-LSG-40-B 2.93 4.01 6.58 K9-LSG-40-B 2.59 3.13 4.38
M8E-LSG-40-B 3.05 4.18 6.96 M8E-LSG-40-B 2.56 3.08 4.28
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software

157 GPC-EN-2024 REFRIGERATION APPLICATIONS


Refrigeration units with semi-hermetic Discus™ compressors

Copeland air-cooled indoor refrigeration units for medium


temperature and low temperature applications.

In a further approach to improve compressor performance and


reduce compression losses, Copeland engineers developed
the Discus valve technology.

This series of refrigeration units is equipped with 2 or 3 cylinder


semi-hermetic compressors with Discus valve technology. The
models are specifically suitable for those applications where
high efficiency and low energy consumption is required.

The wide range of compressor models combined with 2 or 4


fan high capacity condensers covers most application needs Refrigeration units with semi-hermetic
of low temperature and medium temperature applications. Discus compressors

Discus refrigeration units line-up

Medium temperature models

Capacity (kW)
R448A/R449A, EN13215 0 5 10 15 20 25

Low temperature models

Capacity (kW)
R448A/R449A, EN13215 0 2 4 6 8

Features and benefits Maximum allowable pressures (PS)

• Standard equipment: Discus compressor, condenser with • Low Side PS 22.5 bar (g)
thermally protected fan(s), discharge line with flexible pipe • High Side PS = 28 bar (g)
loop or vibration absorber, liquid receiver with shut-off-
valve, HP/LP switch with automatic reset, oil pressure safety
control OPS2
• Suitable for multiple refrigerants: R407A/F, R448A/R449A,
R404A, R134a, R450A and R513A
• Wide range of quality accessories
• Excellent efficiency
• Proven reliability

GPC-EN-2024 REFRIGERATION APPLICATIONS 158


Technical overview

Receiver Capacity

@10m - dB(A)***
Net Weight (kg)

Sound Pressure
Total Fan Motor

Diameter (inch)

Diameter (inch)
Number of fans
Displacement

Suction Line
Maximum

Liquid Line
Power (W)
Motor Version/ Locked Rotor
Operating

(m3/h)
Width/Depth/ Code Current (A)
Model

(l)
Height (mm) Current (A)

3 Ph** 3 Ph** 3 Ph**


P8-2DC-50-B 17 11.7 2 220 1 /8 3
5/8 950/740/633 186 AWM 9 55
R7-2DD-50-B 19 15.8 2 470 1 /8 3
3/4 1130/820/633 196 AWM 10 55
R7-2DL-75-B 24 15.8 2 470 1 3/8 3/4 1130/820/708 205 AWM 14 82
P8-2DB-50-B 28 11.7 2 220 1 /8 3
5/8 950/740/633 186 AWM 13 55 49
P8-2DB-75-B 28 11.7 2 220 1 /8 3
5/8 950/740/633 191 AWM 16 82 52
S9-2DB-75-B 28 15.8 2 470 1 3/8 3/4 1130/820/708 212 AWM 16 82
P8-3DA-50-B 32 11.7 2 220 1 3/8 5/8 950/740/633 205 AWM 16 55 51
P8-3DA-75-B 32 11.7 2 220 1 /8 3
5/8 950/740/633 211 AWM 18 106 52
S9-3DA-75-B 32 18.9 2 470 1 3/8 7/8 1330/820/835 259 AWM 18 106
R7-3DC-100-B 38 15.8 2 470 1 3/8 3/4 1129/820/633 234 AWM 21 121 56
R7-3DC-75-B 38 15.8 2 470 1 /8 3
3/4 1130/820/633 278 AWM 18 82 54
S9-3DS-100-B 50 15.8 2 470 1 /8 3
3/4 1130/820/708 239 AWM 24 121 54
S9-3DS-150-B 50 15.8 2 470 1 3/8 3/4 1129/820/708 243 AWM 29 123 57
** 3 Ph: 380-420V/ 50Hz
*** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

159 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R407A R407A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
P8-2DC-50-B 1.83 2.55 4.47 7.09 8.67 12.30 P8-2DC-50-B 1.61 1.88 2.50 3.22 3.61 4.45
R7-2DD-50-B 2.40 3.35 5.80 9.05 11.00 15.50 R7-2DD-50-B 2.20 2.51 3.20 3.96 4.36 5.22
R7-2DL-75-B 7.05 10.90 13.10 18.20 R7-2DL-75-B 3.98 4.96 5.49 6.64
P8-2DB-75-B 7.85 11.35 13.15 P8-2DB-75-B 4.84 6.31 7.14
S9-2DB-75-B 8.73 13.15 15.65 21.40 S9-2DB-75-B 4.90 6.11 6.76 8.11
P8-2DB-50-B 3.29* 4.46* 7.89 11.30 13.15 P8-2DB-50-B 2.97* 3.50* 4.74 6.22 7.06
P8-3DA-50-B 3.68* 5.00* 8.72 12.10 13.85 P8-3DA-50-B 3.43* 4.07* 5.61 7.44 8.48
S9-3DA-75-B 9.78 14.70 17.50 23.70 S9-3DA-75-B 5.58 7.01 7.76 9.41
P8-3DA-75-B 8.50 12.20 14.15 P8-3DA-75-B 5.48 7.20 8.15
V6-3DC-100-B 12.55 19.10 22.90 31.50 V6-3DC-100-B 6.63 8.20 9.00 10.60
R7-3DC-75-B 4.70* 6.32* 11.05 15.75 18.30 R7-3DC-75-B 4.34* 5.07* 6.77 8.75 9.88
R7-3DC-100-B 11.05 16.15 18.85 R7-3DC-100-B 6.53 8.52 9.62
W9-3DS-150-B 16.25 24.20 28.70 38.80 W9-3DS-150-B 8.82 11.05 12.25 14.70
S9-3DS-100-B 6.34* 8.54* 14.65 20.50 23.60 S9-3DS-100-B 5.71* 6.67* 8.99 11.75 13.35
V6-3DS-150-B 16.05 23.80 28.20 37.80 V6-3DS-150-B 8.85 11.15 12.40 15.00
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R448A R448A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
P8-2DC-50-B 1.71* 2.83 4.92 7.59 9.13 12.60 P8-2DC-50-B 1.65* 1.96 2.67 3.42 3.82 4.63
R7-2DD-50-B 2.04* 3.34 5.84 9.15 11.10 15.65 R7-2DD-50-B 2.16* 2.48 3.20 3.99 4.42 5.34
R7-2DL-75-B 2.79* 4.24 7.12 11.00 13.35 18.75 R7-2DL-75-B 2.78* 3.14 3.97 4.98 5.55 6.84
P8-2DL-75-B 2.65* 3.68* 6.65 10.05 12.00 P8-2DL-75-B 2.54* 2.90* 3.80 4.92 5.59
P8-2DB-75-B 3.74* 4.95* 8.20 11.65 13.55 P8-2DB-75-B 3.24* 3.74* 4.95 6.42 7.26
S9-2DB-75-B 4.02* 5.38* 9.13 13.60 16.25 22.20 S9-2DB-75-B 3.43* 3.90* 4.97 6.18 6.83 8.25
P8-2DB-50-B 3.58* 4.76* 7.98 11.40 13.25 P8-2DB-50-B 3.02* 3.55* 4.82 6.37 7.25
P8-3DA-75-B 3.80* 5.25* 9.03 12.95 15.10 P8-3DA-75-B 3.56* 4.22* 5.71 7.39 8.31
S9-3DA-75-B 4.24* 5.91* 10.35 15.45 18.40 25.10 S9-3DA-75-B 3.81* 4.44* 5.76 7.14 7.86 9.36
P8-3DA-50-B 3.98* 5.19* 8.61 12.15 P8-3DA-50-B 3.51* 4.12* 5.59 7.36
R7-3DC-75-B 5.12* 6.65* 11.00 15.80 18.45 R7-3DC-75-B 4.46* 5.14* 6.77 8.70 9.79
R7-3DC-100-B 4.59* 6.58* 11.45 16.45 19.15 R7-3DC-100-B 4.08* 4.90* 6.68 8.69 9.79
V6-3DC-100-B 5.18* 7.86 13.15 19.75 23.50 32.00 V6-3DC-100-B 4.46* 5.23 6.79 8.34 9.12 10.70
W9-3DS-150-B 7.77* 10.35* 17.20 25.00 29.40 39.30 W9-3DS-150-B 6.29* 7.19* 9.16 11.30 12.50 14.95
V6-3DS-150-B 7.70* 10.25* 17.00 24.60 28.80 38.30 V6-3DS-150-B 6.30* 7.21* 9.21 11.40 12.60 15.20
S9-3DS-100-B 6.96* 9.00* 14.80 21.20 S9-3DS-100-B 5.84* 6.78* 9.09 11.90
S9-3DS-150-B 7.17* 9.47* 15.35 21.30 24.40 S9-3DS-150-B 6.06* 7.03* 9.27 11.85 13.30
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary Data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R449A R449A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
P8-2DC-50-B 1.70* 2.83 4.92 7.59 9.13 12.60 P8-2DC-50-B 1.65* 1.96 2.67 3.42 3.82 4.63
R7-2DD-50-B 2.02* 3.34 5.86 9.15 11.10 15.55 R7-2DD-50-B 2.11* 2.48 3.26 4.07 4.48 5.29
P8-2DL-75-B 2.64* 3.67* 6.65 10.05 12.00 P8-2DL-75-B 2.54* 2.90* 3.80 4.92 5.59
R7-2DL-75-B 2.78* 4.24 7.12 11.00 13.35 18.75 R7-2DL-75-B 2.78* 3.14 3.97 4.98 5.55 6.84
P8-2DB-50-B 3.55* 4.75* 8.00 11.40 13.25 P8-2DB-50-B 3.05* 3.57* 4.82 6.35 7.23
P8-2DB-75-B 3.73* 4.94* 8.21 11.65 13.50 P8-2DB-75-B 3.23* 3.74* 4.95 6.42 7.26
S9-2DB-75-B 4.01* 5.36* 9.15 13.60 16.25 22.10 S9-2DB-75-B 3.44* 3.91* 4.98 6.18 6.83 8.26
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary Data

GPC-EN-2024 REFRIGERATION APPLICATIONS 160


Capacity data
Ambient Temperature: 32°C
Cooling Capacity (kW) Power Input (kW)
R449A R449A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
S9-3DA-75-B 4.23* 5.90* 10.35 15.45 18.40 25.10 S9-3DA-75-B 3.81* 4.44* 5.76 7.14 7.86 9.36
P8-3DA-50-B 3.97* 5.18* 8.61 12.15 P8-3DA-50-B 3.51* 4.12* 5.59 7.36
P8-3DA-75-B 3.79* 5.24* 9.03 12.95 15.10 P8-3DA-75-B 3.56* 4.22* 5.71 7.39 8.31
R7-3DC-100-B 4.59* 6.56* 11.45 16.50 19.20 R7-3DC-100-B 4.07* 4.84* 6.56 8.54 9.64
V6-3DC-100-B 5.16* 7.83 13.10 19.65 23.40 32.00 V6-3DC-100-B 4.44* 5.17 6.67 8.24 9.06 10.75
R7-3DC-75-B 5.11* 6.63* 11.00 15.80 18.45 R7-3DC-75-B 4.46* 5.14* 6.77 8.70 9.79
S9-3DS-150-B 7.25* 9.47* 15.30 21.20 24.30 S9-3DS-150-B 6.12* 7.05* 9.25 11.85 13.30
S9-3DS-100-B 6.94* 8.98* 14.80 21.20 S9-3DS-100-B 5.84* 6.78* 9.09 11.90
V6-3DS-150-B 7.76* 10.25* 16.95 24.50 28.80 38.20 V6-3DS-150-B 6.34* 7.21* 9.18 11.40 12.60 15.20
W9-3DS-150-B 7.82* 10.35* 17.15 24.90 29.40 39.20 W9-3DS-150-B 6.32* 7.19* 9.13 11.30 12.45 15.00
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary Data

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R404A R404A
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
P8-2DC-50-B 2.36 3.17 5.24 7.92 9.48 12.95 P8-2DC-50-B 1.96 2.27 2.96 3.67 4.03 4.74
R7-2DD-50-B 3.06 4.12 6.69 9.89 11.70 15.85 R7-2DD-50-B 2.63 3.00 3.76 4.53 4.91 5.64
R7-2DL-75-B 3.84 5.02 8.00 11.75 13.85 18.55 R7-2DL-75-B 3.15 3.58 4.54 5.59 6.14 7.27
P8-2DB-50-B 1.95* 4.56 5.85 8.86 12.25 P8-2DB-50-B 2.46* 3.44 4.04 5.43 6.99
S9-2DB-75-B 5.10 6.53 9.97 14.20 16.65 21.90 S9-2DB-75-B 3.91 4.42 5.60 6.88 7.55 8.87
P8-2DB-75-B 4.76 6.02 8.89 12.20 13.95 P8-2DB-75-B 3.70 4.23 5.46 6.89 7.65
S9-3DA-75-B 5.42 7.14 11.15 16.00 18.65 24.50 S9-3DA-75-B 4.36 5.06 6.50 7.97 8.72 10.25
P8-3DA-75-B 4.96 6.46 9.79 13.45 15.35 P8-3DA-75-B 4.09 4.82 6.40 8.12 9.03
P8-3DA-50-B 2.27* 5.36 6.70 9.64 12.85 P8-3DA-50-B 2.91* 4.23 4.96 6.53 8.26
R7-3DC-100-B 6.32 8.19 12.25 16.60 18.90 R7-3DC-100-B 5.09 5.93 7.76 9.75 10.80
R7-3DC-75-B 3.08* 6.71 8.36 12.05 16.15 R7-3DC-75-B 3.87* 5.36 6.18 7.94 9.89
V6-3DC-100-B 7.08 9.30 14.55 20.90 24.50 32.50 V6-3DC-100-B 5.41 6.18 7.75 9.31 10.05 11.45
S9-3DS-100-B 4.24* 9.04 11.25 16.15 21.50 S9-3DS-100-B 5.13* 7.07 8.20 10.70 13.50
W9-3DS-150-B 9.44 12.20 18.65 26.20 30.50 39.70 W9-3DS-150-B 7.07 8.18 10.50 12.85 14.00 16.15
V6-3DS-150-B 9.38 12.15 18.50 25.90 30.10 39.10 V6-3DS-150-B 7.07 8.19 10.55 12.90 14.10 16.30
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

Ambient Temperature: 32°C


Cooling Capacity (kW) Power Input (kW)
R134a R134a
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
P8-2DB-50-B 5.14 8.36 10.25 14.45 P8-2DB-50-B 2.81 3.67 4.13 5.08
P8-3DA-50-B 5.77 9.21 11.20 15.70 P8-3DA-50-B 3.23 4.16 4.66 5.75
R7-3DC-75-B 7.27 11.50 13.95 19.60 R7-3DC-75-B 4.10 5.19 5.78 7.01
S9-3DS-100-B 9.50 14.90 18.10 25.30 S9-3DS-100-B 5.16 6.73 7.57 9.35
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software

161 GPC-EN-2024 REFRIGERATION APPLICATIONS


Refrigeration units with semi-hermetic Stream compressors

Copeland air-cooled indoor refrigeration units for low, medium


and high temperature applications.

This series of refrigeration units is equipped with 4 or 6 cylinder


high performance semi-hermetic Stream compressors. These
models are specifically suitable for those applications where high
efficiency and reliability is required to achieve low lifecycle costs.

Multiple refrigerant approvals and wide range of accessories


improve flexibility in system design.

Refrigeration units with


semi-hermetic Stream compressors

Refrigeration units with Stream compressor line-up

Medium temperature models

Capacity (kW)
R448A/R449A, EN13215 0 10 20 30 40 50 60

Low temperature models

Capacity (kW)
R448A/R449A, EN13215 0 5 10 15 20

Features and benefits Maximum allowable pressures (PS)

• Standard equipment: Stream compressor, condenser with • Low pressure side = 22.5 bar
thermally protected fan(s), discharge line with flexible pipe • High pressure side = 28 bar
loop or vibration absorber, liquid receiver with shut-off-valve,
HP/LP switch with automatic reset.
• Suitable for multiple refrigerants: R407A/F, R448A/R449A,
R404A, R134a, R450A and R513A
• Wide range of quality accessories
• Excellent efficiency
• Proven reliability

GPC-EN-2024 REFRIGERATION APPLICATIONS 162


Technical overview

@10m - dB(A)***
Number of Fans

Sound Pressure
Net Weight (kg)
Total Fan Motor

Diameter (inch)

Diameter (inch)
Maximum

Displacement

Suction Line
Capacity (l)
Motor Version/ Locked Rotor

Liquid Line
Power (W)
Operating Current

Receiver
(m3/h)
Code Current (A)
Model (A)

3 Ph** 3 Ph** 3 Ph**

W99-6MI-40 121 47.9 4 1600 2 1/8 7/8 521 AWM 71 304 59


Z9-4MA-22 62 18.9 4 1600 1 /8 5
7/8 383 AWM 36 175 59
V6-4ML-15 71 18.9 2 800 1 5/8 7/8 303 AWM 35 156 57
V6-4MF-13 62 18.9 2 800 1 /8 5
7/8 295 AWM 31 105 57
Z9-4MH-25 71 18.9 4 1600 2 1/8 7/8 389 AWM 42 199 59
Z9-4MI-30 78 18.9 4 1600 2 /8 1
7/8 416 AWM 47 221 59
Z9-4MJ-33 88 18.9 4 1600 2 1/8 7/8 416 AWM 53 221 59
W9-4MT-22 88 18.9 2 800 2 /8 1
7/8 358 AWM 45 175 59
W9-4MM-20 78 18.9 2 800 2 /8 1
7/8 358 AWM 39 175 57
Z9-4MU-25 100 18.9 4 1600 2 1/8 7/8 392 AWM 52 199 59
Z9-6MM-30 121 18.9 4 1600 2 /8 1
7/8 410 AWM 60 255 59
W99-4MK-35 121 47.9 4 1600 2 1/8 7/8 504 AWM 61 255 59
** 3 Ph: 380-420V/ 50Hz
*** @ 10m: sound pressure level at 10m distance from the compressor, free field condition

163 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data

Cooling Capacity (kW) Power Input (kW)

R407A Ambient Temperature: 32°C R407A Ambient Temperature: 32°C

Evaporating Temperature (°C) Evaporating Temperature (°C)

Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5

Z9-4MA-22 20.90 32.00 38.70 54.50 Z9-4MA-22 10.95 13.30 14.50 17.00

V6-4MF-13 7.48* 10.30* 18.35 26.50 31.00 V6-4MF-13 6.88* 8.08* 10.85 14.00 15.75

V6-4ML-15 9.29* 12.60* 21.70 30.90 35.90 V6-4ML-15 8.22* 9.62* 12.85 16.70 18.90

Z9-4MH-25 24.40 36.60 43.90 60.90 Z9-4MH-25 12.90 15.65 17.05 20.00

Z9-4MI-30 26.60 40.00 47.90 66.10 Z9-4MI-30 14.15 17.35 19.00 22.50

W9-4MM-20 10.45* 13.95* 23.80 33.80 39.20 W9-4MM-20 9.04* 10.60* 14.25 18.45 20.90

W9-4MT-22 11.10* 14.70* 25.10 35.20 40.60 W9-4MT-22 10.25* 12.05* 16.35 21.40 24.30

Z9-4MJ-33 29.30 43.60 52.00 71.20 Z9-4MJ-33 15.85 19.55 21.50 25.80

W99-4MK-35 32.40 47.90 56.80 76.60 W99-4MK-35 18.05 22.60 25.00 30.40

Z9-4MU-25 13.15* 19.80 31.70 46.50 55.00 Z9-4MU-25 12.05* 13.95 18.05 22.80 25.50

Z9-6MM-30 15.80* 23.70 37.50 54.50 64.00 Z9-6MM-30 14.15* 16.50 21.70 27.60 30.90

W99-6MI-40 38.40 56.20 66.10 87.70 W99-6MI-40 21.60 27.30 30.50 37.50
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

Cooling Capacity (kW) Power Input (kW)


R407F Ambient Temperature: 32°C R407F Ambient Temperature: 32°C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
V6-4MF-13 8.04* 11.00* 18.05* 27.50 32.10 V6-4MF-13 7.23* 8.51* 11.40* 14.85 16.80
Z9-4MA-22 21.30* 34.10 41.10 57.50 Z9-4MA-22 11.60* 14.15 15.45 17.90
Z9-4MH-25 24.40* 38.70 46.50 64.50 Z9-4MH-25 13.30* 16.50 18.10 21.30
V6-4ML-15 9.88* 13.30* 21.40* 32.40 V6-4ML-15 8.61* 10.10* 13.55* 17.90
Z9-4MI-30 26.90* 42.00 50.20 68.90 Z9-4MI-30 14.70* 18.10 19.90 23.80
W9-4MM-20 10.90* 14.60* 23.30* 35.10 W9-4MM-20 9.55* 11.20* 15.00* 19.60
Z9-4MJ-33 29.60* 45.90 54.60 74.10 Z9-4MJ-33 16.50* 20.60 22.90 27.70
Z9-4MU-25 14.75* 19.75* 32.20* 49.50 58.50 Z9-4MU-25 12.65* 14.65* 19.10* 24.40 27.30
W99-4MK-35 32.50* 50.30 59.50 79.80 W99-4MK-35 18.85* 23.60 26.40 32.60
Z9-6MM-30 17.70* 23.70* 38.10* 58.00 68.10 Z9-6MM-30 15.05* 17.40* 22.80* 29.30 32.80
W99-6MI-40 38.30* 58.90 69.20 91.50 W99-6MI-40 23.20* 29.10 32.40 40.00
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

GPC-EN-2024 REFRIGERATION APPLICATIONS 164


Capacity data

Cooling Capacity (kW) Power Input (kW)


R448A Ambient Temperature: 32°C R448A Ambient Temperature: 32°C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
V6-4MF-13 8.40* 11.00* 18.15 25.80 30.10 V6-4MF-13 7.05* 8.23* 11.05 14.40 16.25
Z9-4MA-22 8.98* 13.05 21.80 33.60 40.80 57.80 Z9-4MA-22 7.80* 8.95 11.25 13.60 14.80 17.20
Z9-4MH-25 10.55* 15.20 24.90 37.50 45.00 62.20 Z9-4MH-25 9.13* 10.40 13.15 16.10 17.65 20.90
V6-4ML-15 10.45* 13.75* 22.40 31.60 36.60 V6-4ML-15 8.40* 9.81* 13.15 17.25 19.70
Z9-4ML-15 11.45* 15.95 25.30 37.30 44.30 Z9-4ML-15 9.09* 10.35 13.15 16.25 17.95
W9-4MM-20 11.70* 15.25* 24.50 34.10 39.20 W9-4MM-20 9.33* 10.90* 14.60 19.25 22.00
Z9-4MM-20 12.70* 17.60 27.70 40.30 47.50 Z9-4MM-20 9.98* 11.40 14.45 18.00 19.95
Z9-4MI-30 11.90* 17.15 27.90 41.70 49.70 68.20 Z9-4MI-30 9.80* 11.35 14.55 17.95 19.65 23.20
Z9-4MT-22 14.35* 18.80* 30.70 44.50 52.40 Z9-4MT-22 11.15* 12.75* 16.40 20.50 22.80
Z9-4MJ-33 13.15* 18.75 30.30 45.00 53.60 73.30 Z9-4MJ-33 10.80* 12.50 16.20 20.20 22.30 26.80
W99-4MK-35 14.70* 19.75* 33.40 49.30 58.50 79.30 W99-4MK-35 12.25* 14.20* 18.55 23.30 25.90 31.30
Z9-4MU-25 15.15* 19.95* 33.10 48.30 57.10 Z9-4MU-25 12.25* 14.15* 18.50 23.60 26.50
Z9-6MM-30 18.25* 24.00* 39.10 55.50 64.60 Z9-6MM-30 14.60* 16.95* 22.20 28.10 31.40
W99-6MI-40 17.75* 23.90* 40.00 57.70 67.50 88.50 W99-6MI-40 14.50* 16.85* 21.90 27.70 30.90 37.90
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary Data

Cooling Capacity (kW) Power Input (kW)


R449A Ambient Temperature: 32°C R449A Ambient Temperature: 32°C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
V6-4MF-13 8.37* 11.00* 18.15 25.80 30.10 V6-4MF-13 7.05* 8.23* 11.05 14.40 16.25
Z9-4MA-22 8.95* 13.05 21.80 33.60 40.80 57.80 Z9-4MA-22 7.80* 8.95 11.25 13.60 14.80 17.20
Z9-4MH-25 10.50* 15.20 24.90 37.50 45.00 62.20 Z9-4MH-25 9.13* 10.40 13.15 16.10 17.65 20.90
V6-4ML-15 10.40* 13.70* 22.40 31.60 36.60 V6-4ML-15 8.40* 9.81* 13.15 17.25 19.70
W9-4MM-20 11.65* 15.20* 24.50 34.10 39.20 W9-4MM-20 9.33* 10.90* 14.60 19.25 22.00
Z9-4MJ-33 13.15* 18.75 30.30 45.00 53.60 73.30 Z9-4MJ-33 10.80* 12.50 16.20 20.20 22.30 26.80
W9-4MT-22 13.05* 16.85* 27.00 37.20 W9-4MT-22 10.50* 12.35* 16.70 22.10
Z9-4MU-25 15.10* 19.90* 33.10 48.30 57.10 Z9-4MU-25 12.25* 14.15* 18.50 23.60 26.50
W99-4MK-35 14.65* 19.70* 33.40 49.30 58.50 79.30 W99-4MK-35 12.25* 14.20* 18.55 23.30 25.90 31.30
W99-6MI-40 17.70* 23.80* 40.00 57.70 67.50 88.50 W99-6MI-40 14.50* 16.85* 21.90 27.70 30.90 37.90
Z9-6MM-30 18.20* 24.00* 39.10 55.50 64.60 Z9-6MM-30 14.60* 16.95* 22.20 28.10 31.40
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K
Preliminary Data

165 GPC-EN-2024 REFRIGERATION APPLICATIONS


Capacity data
Cooling Capacity (kW) Power Input (kW)
R404A Ambient Temperature: 32°C R404A Ambient Temperature: 32°C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
V6-4MF-13 4.26* 10.75 13.65 20.40 28.40 32.80 V6-4MF-13 5.84* 8.22 9.50 12.25 15.25 16.90
Z9-4MA-22 11.65 15.30 24.00 34.80 41.00 55.00 Z9-4MA-22 8.86 10.10 12.50 14.85 15.95 18.15
Z9-4MH-25 13.40 17.50 27.30 39.60 46.70 62.80 Z9-4MH-25 10.20 11.60 14.55 17.55 19.05 22.00
V6-4ML-15 5.41* 13.00 16.35 23.90 32.60 37.20 V6-4ML-15 7.08* 9.86 11.45 14.90 18.65 20.60
W9-4MM-20 6.27* 14.50 18.05 25.90 34.60 39.20 W9-4MM-20 7.89* 10.95 12.70 16.45 20.70 23.00
Z9-4MI-30 15.40 19.95 30.50 43.10 50.30 66.10 Z9-4MI-30 11.35 13.00 16.25 19.55 21.20 24.60
Z9-4MJ-33 17.00 21.80 33.20 46.90 54.60 71.60 Z9-4MJ-33 12.40 14.15 17.90 21.80 23.80 27.80
W9-4MT-22 7.18* 15.90 19.70 28.10 37.60 W9-4MT-22 8.83* 12.35 14.35 18.70 23.60
Z9-4MU-25 8.35* 19.15 24.20 36.10 50.70 Z9-4MU-25 10.50* 14.40 16.45 20.90 25.50
W99-4MK-35 18.90 24.10 36.50 51.30 59.60 77.80 W99-4MK-35 14.10 16.15 20.50 25.20 27.60 32.40
Z9-6MM-30 10.10* 22.80 28.40 41.80 58.10 67.20 Z9-6MM-30 12.75* 17.50 20.00 25.30 31.20 34.30
W99-6MI-40 22.10 28.20 42.30 58.80 67.90 87.30 W99-6MI-40 16.75 19.30 24.80 30.60 33.60 40.00
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
* Conditions: EN13215: Suction Superheat 10K

Cooling Capacity (kW) Power Input (kW)


R407C Ambient Temperature: 32°C R407C Ambient Temperature: 32°C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Z9-4MA-22 19.95 30.40 36.70 51.50 Z9-4MA-22 10.65 12.85 13.90 15.95
Z9-4MH-25 22.70 34.80 42.00 58.80 Z9-4MH-25 12.15 14.80 16.10 18.80
Z9-4MI-30 25.30 38.30 46.00 64.00 Z9-4MI-30 13.35 16.40 17.95 21.10
Z9-4MJ-33 27.80 42.00 50.40 69.60 Z9-4MJ-33 14.80 18.35 20.20 24.30
W99-4MK-35 31.90 47.70 56.90 77.50 W99-4MK-35 16.90 21.20 23.50 28.50
W99-6MI-40 36.20 53.50 63.30 84.50 W99-6MI-40 20.00 25.50 28.40 34.90
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
Preliminary Data

Cooling Capacity (kW) Power Input (kW)


R134a Ambient Temperature: 32°C R134a Ambient Temperature: 32°C
Evaporating Temperature (°C) Evaporating Temperature (°C)
Model -45 -35 -30 -20 -10 -5 +5 Model -45 -35 -30 -20 -10 -5 +5
Z9-4MA-22 13.95 21.90 26.90 39.10 Z9-4MA-22 7.41 8.79 9.44 10.60
V6-4MF-13 12.45 19.55 23.90 33.80 V6-4MF-13 6.57 8.24 9.09 10.90
V6-4ML-15 14.80 22.90 27.70 38.60 V6-4ML-15 7.72 9.77 10.85 13.20
Z9-4MH-25 15.80 24.90 30.60 44.40 Z9-4MH-25 8.53 10.20 11.05 12.60
Z9-4MI-30 17.45 27.20 33.30 47.90 Z9-4MI-30 9.11 11.00 11.95 13.80
W9-4MM-20 16.40 25.20 30.30 42.10 W9-4MM-20 8.52 10.75 11.95 14.55
W9-4MT-22 18.55 28.10 33.60 45.90 W9-4MT-22 9.70 12.30 13.75 16.95
Z9-4MJ-33 19.45 30.10 36.70 52.40 Z9-4MJ-33 10.20 12.25 13.35 15.50
Z9-4MU-25 21.10 33.30 40.70 58.00 Z9-4MU-25 11.25 13.95 15.30 18.25
W99-4MK-35 21.80 33.70 41.00 58.50 W99-4MK-35 11.20 13.80 15.15 17.95
W99-6MI-40 25.20 39.00 47.40 67.30 W99-6MI-40 13.50 16.50 18.15 21.70
Z9-6MM-30 25.30 39.10 47.50 66.70 Z9-6MM-30 13.30 16.65 18.45 22.10
Conditions: EN13215: Suction Gas Return 20°C, Subcooling 0K For detailed capacity data please refer to Copeland Select software
Refer to Copeland Select software for R450A and R513A capacity data.

GPC-EN-2024 REFRIGERATION APPLICATIONS 166


Compressors motor codes table

Semi-Hermetic
Motor Codes Voltage Connection Motor Codes Voltage Connection
Standard Motor Version
CAG 220-230/1/50 -
EWL (DK, DL, D2S) 220-240/3/50 Δ EWN (DK, DL, D2S) 250-280/3/60 Δ
EWL (DK, DL, D2S) 380-420/3/50 Y EWN (DK, DL, D2S) 440-480/3/60 Y
AWM 380-420/3/50 YY/Y AWD 440-480/3/60 YY/Y
Special Motor Version
EWM 380-420/3/50 Δ/Y-Start EWD 440-480/3/60 Δ/Y-Start
AWR 220-240/3/50 YY/Y EWK (not D8) 220-240/3/60 Δ
AWY 500-550/3/50 YY/Y EWK (not D8) 380-420/3/60 Y
AWC 208-230/3/60 YY/Y
AWX 380/3/60 YY/Y

Hermetic & Scroll


Motor Codes Voltage Connection Motor Codes Voltage Connection
Standard Motor Version
PFJ 220-240/1/50 - PFJ 265/1/60 -
PFT 220-240/1/50 -
PFZ 220-240/1/50 -
TFD 380-420/3/50 Y TFD 460/3/60 Y
TFM 380-420/3/50 Y
TWD 380-420/3/50 Y TWD 460/3/60 Y
FWD 380-420/3/50 Δ/Δ
FWM 380-420/3/50 Δ/Δ
TWM 380-420/3/50 Y
Special Motor Version
TF5 200-220/3/50 Y TF5 200-230/3/60 Y
TWR 220-240/3/50 Y TW7 380/3/60 Y
TWC 200/3/50 Y TWC 208-230/3/60 Y
TFE 500/3/50 Y TFE 575/3/60 Y
TWE 500/3/50 Y TWE 575/3/60 Y
TF7 380/3/60 Y
TW5 200-220/3/50 Y TW5 220-230/3/60 Y
Variable Speed Motor Version
*E9 BPM Motor -

YY/Y = Part-Winding-Start
Δ/Δ = Part-Winding-Start

167 GPC-EN-2024 REFRIGERATION APPLICATIONS


GPC-EN-2024 REFRIGERATION APPLICATIONS 168
169 GPC-EN-2024 REFRIGERATION APPLICATIONS
Controls components

GPC-EN-2024 CONTROLS COMPONENTS 170


Controls components

Copeland offers precision mechanical controls for the The compressor soft starter allows keeping the starting current
refrigeration and air conditioning markets, and together with below the limit imposed in residential heat pump applications.
the range of electronic controls we continue to pioneer the
control of refrigerant flow with innovative design, keeping system Electronic fan speed controllers help to maintain a minimum
performance optimization central to our product development. condensing pressure by reducing fan speed at low ambient
temperature.
The wide range of Copeland controllers covers all major
applications in commercial air conditioning and refrigeration, as Make use of Copeland pressure transmitters, temperature
well as heat pump systems. There are stand-alone controllers sensors and other assorted accessories compatible with all of
and controllers with a communication interface. the above-mentioned controllers.

Copeland offers stepper motor drivers and superheat controllers Oil management components feature active oil level monitoring
for the electrically driven control valves, as well as capacity and balancing for optimal compressor protection. The patented
controllers for Copeland digital scroll compressors. See section TraxOil™ 3-zone level control technology is unique and offers
“Electronic Controllers and Sensors” for more details. comfortable monitoring and proactively protects the compressor
against low oil levels.
Display case and cold room controllers provide all functions
needed to run commercial refrigeration, like superheat control Copeland’s controls portfolio is completed by offering a variety
with electrical control valve, thermostat, fan and defrost control, of mechanical controls such as:
integrated timer and alarm functions. - Pressostats & thermostats
- System protectors
- Solenoid valves
- Ball valves
- Moisture indicators
- Thermo™-expansion valves
- Oil separators
- Suction accumulators

171 GPC-EN-2024 CONTROLS COMPONENTS


Electrical control
Electricalvalves
Control Valves

Electrical control valves

Electrical control valve technology cage assembly of the valve. Similar to the technology used in
compressors, the motor is exposed to refrigerant and lubricant
Thermostatic expansion valves and mechanical regulator and the materials used are identical to the ones in compressor
valves have been used in the refrigeration and air conditioning motors. The housing of the motor and valve assembly is made
industry to control superheat and refrigerant mass flow since from stainless steel and fully hermetic, utilising exclusively
its very beginning. As today’s systems require improved energy brazing and welding technologies and eliminating all gaskets.
efficiency, tighter temperature control, a wider range of operating This design offers several technical advantages such as
conditions and incorporate new features like remote monitoring proportional linear mass flow and a wide capacity range. A
and diagnostics, the application of electronically operated valves common feature of all EX2, EX4-8 electrical control valves is
becomes mandatory. Only these offer the controls performance the positive shut-off function, which eliminates the need for
necessary to meet these needs. Electrical control valves are additional solenoid valves.
actuators only. For operation in a system they need sensors,
valve drivers and controllers, see next chapter. The CV4-7 high pressure expansion valves are stepper motor
driven valves for precise control of R744 (CO2) refrigerant mass
The EXM/EXL/EXN biflow valves for OEM use are equipped flow in air conditioning, refrigeration and heat pump applications.
with an unipolar stepper motor drive. They are mainly used for The Control Valves also can be used for liquid injection duty and
heat pumps, air conditioning and close control. hot gas bypass.

The EX2 is designed for pulse width modulation. It is applicable


to common refrigerants and is used mainly for refrigeration
Valve selection
applications such as display cases. The EX2 valve is a slide type For the EX2, the published table quotes capacities at 100% duty
solenoid valve with an orifice for expansion. It is either completely cycle, i.e. valve open continuously. However, it is recsommended
open or completely closed. One common valve body can be to operate the valve at partial load (50-80%) to allow for system
combined with 6 interchangeable orifices to cover 7 capacity load fluctuations. For EX4-8 and EXM/EXL/EXN valves, all
ranges. The CX2 features the same technology and advantages published capacities are maximum and there are no reserve
as the EX2, however it is applicable to high-pressure CO2 capacities. Each valve should be selected for the highest
applications. possible capacity of the system. A wide range regulation (10
… 100%) with one slide orifice for each valve is achievable. To
The EX4-8 consist of two main internal assemblies, the valve facilitate valve dimensioning for other conditions, please use
and the stepper motor. The stepper motor is located next to Copeland Select software. It can be downloaded from copeland.
the electrical plug and connected directly to the slide and com/en-gb.

GPC-EN-2024 CONTROLS COMPONENTS 172


Selection table for electrical control valves and applicable controllers

Capacity (kW)
Valve Type Function Feature Main Application Applicable Controller
R407C

Heat pumps,
EXM/ Uni Polar Stepper EXD-HP1/2 Superheat
Expansion Valve 1.6 .. 20.7 Air Conditioning,
EXL Motor Driven Controller (Modbus)
Close Control
Heat Pumps, Air
Uni Polar Stepper EXD-HP1/2 Superheat
EXN Expansion Valve 30 .. 38 Conditioning, Close
Motor Driven Controller (Modbus)
Control
Refrigeration
EX2 Expansion Valve 1.0 .. 18.7 PWM
(Display cases)
Expansion Valve,
Hot Gas Bypass,
Condensing Pressure Refrigeration,
EXD-U02 Driver Module
And Liquid Regulator, 17.4 ... 925 (Capacity Bi Polar Stepper Air Conditioning,
EX4-8 EXD-SH1/2 Superheat
Head Pressure Control, Data as Expansion Valve) Motor Driven Water Chillers,
Controller (Modbus)
Suction/Crankcase Heat Pumps
Pressure Regulator,
Heat Reclaim

Selection table for electrical control valves and applicable controllers for CO2 applications
Capacity (kW)
Valve Type Function Feature Main Application Applicable Controller
R744

Refrigeration
CX2 Expansion Valve 1.5 ... 28.2 PWM
(Display cases)
EXD-U02 Driver Module
Bi Polar stepper Refrigeration
EX4-8 Expansion Valve 27 ... 1440 EXD-SH1/2 Superheat
Motor Driven subcritical CO2
Controller (Modbus)

Expansion Valve Refrigeration EXD-U02 Driver Module


Bi Polar stepper
CV4-6.5 HP Gas Valve Kv 0.21 ... 2.6 m3/h subcritical and EXD-SH1/2 Superheat
Motor Driven
Heat Recllaim Valve transcritical CO2 Controller (Modbus)

173 GPC-EN-2024 CONTROLS COMPONENTS


Electrical control valves series EXM/EXL for OEM use, stepper motor driven

Features

• Unipolar stepper motor


• Bi-flow (same performance in both flow directions in term of
capacity)
• High MOPD: 40 bar in normal flow direction
• Removable coils in two versions: 12 VDC/24 VDC
• Continuous modulation of mass flow, no stress (liquid hammering)
in the refrigeration circuit
• Linear flow
• Resolution: 500 pulses (half steps) or 250 full steps
• Hermetic design
• Reliability: 225 millions pulses at continuous 40 bar
differential pressure
• VDE tested according to IEC-60335-2-89 and IEC-60335-2-40
EXM/EXL
Note: The valve is not released for refrigeration applications such as cold rooms and
refrigeration display cabinets.

Selection table
Nominal Capacity (kW)
Part No. Connections
Valve Series Description Type
(10 pcs) R32 R452B R454B R410A R407C R134a Size / Style

EXM-B0A 800 399M 2.7 2.1 2.1 1.8 1.6 1.2


EXM-B0B 800 400M 8.2 6.3 6.3 5.5 5.0 3.7
Valve less coil 1/4” ODM
EXM-B0D 800 401M 17.3 13.3 13.3 11.6 10.5 7.7
EXM
EXM-B0E 800 402M 20.4 15.7 15.7 13.7 12.4 9.1
Coil 12VDC EXM-125 800 403M - - - - - -
-
Coil 24VDC EXM-24U 800 415M - - - - - -
EXL-B1F 800 405M 25.3 19.4 19.4 17.0 15.4 11.3 1/4” ODF
Valve less coil
EXL-B1G 800 406M 34.2 26.3 26.4 23.0 20.7 15.2 8 mm ODM
EXL
Coil 12VDC EXL-125 800 407M - - - - - -
-
Coil 24VDC EXL-24U 800 416M - - - - - -
Note 1: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: For the selection of other operation conditions, please use Copeland Select software.
Note 3: When selecting also observe the information in the operating instructions. Available for download on the Copeland website.

Technical data

Max. allowable 16.6 Seconds at 30 pulse/sec.


45 bar Full travel time
pressure PS 5.5 seconds at 90 pulse/sec.

Reference position Mechanical stop at fully close position


40 bar in Normal Flow Direction,
MOPD
30 bar Reverse Flow Direction
Total number of pulses 500 half step (250 full step)
-30...+70°C (Liquid Refrigerant)
Temperature range TS
-30...+60°C (Ambient) EXM: A
Insulation class
EXL: E

Stepper motor type Uni-polar, Constant Voltage


Cable length 1m

GPC-EN-2024 CONTROLS COMPONENTS 174


Electrical control valves series EXN for OEM use, stepper motor driven

Features

• Unipolar stepper motor


• Bi-flow with same capacity in normal and reverse flow direction
• MOPD: 36 bar in both flow directions
• Unipolar stepper motor with gear mechanism enabling Bi-flow
performance at 36 bar differential pressure across the valve
• Removable coil: 12 VDC
• Continuous, linear modulation of mass flow
• High resolution: 2000 pulses (half steps) or 1000 full steps
• Hermetic design

EXN with coil

Selection table
Nominal Capacity (kW) Connections
Type Description Part No.
R410A R32 R134a R407C Size / Style

EXN-B2K Valve less coil 800421 34.0 50.6 22.2 30.7 1/2” ODF
EXN-B2L Valve less coil 800422 42.0 62.5 28.8 37.9 1/2” ODF
EXN-125 Coil 12 VDC 800420 - - - - -
Note 1: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: For the selection of other operation conditions, please use Copeland Select software.

Technical data

MOPD Total number of pulses 2000 half step (1000 full step)
36 bar in Normal Flow
(Maximum Operating
36 bar in Reverse Flow
Pressure Differential)
Pulsing rate frequency
100…200 Hz
(pulse/sec.)
Max. allowable pressure PS 45 bar

20 s at 100 Hz
Temperature range TS Full travel time
10 s at 200 Hz
- liquid refrigerant -30…+70°C
- Ambient -30…+60°C
Coil insulation class A

Stepper motor type Uni-Polar, Constant Voltage, 5 Wires Cable length 1m

JST XH connector, 5 pole


Supply voltage 12 VDC Coil: 12 V ± 10% Electrical connection Housing: XHP-5
Pin: SXH-001T-P0.6

175 GPC-EN-2024 CONTROLS COMPONENTS


Electronic expansion valves series EX2 pulse width modulated with
exchangeable orifices can be used with EC2 display case controllers

Features

• Pulse width modulated


• Shut-off function eliminates the necessity of a separate solenoid valve
• Dampened plunger reduces noise effects of water hammer
• One valve body can be combined with 6 orifices to make 7 capacity ranges
• Long lifetime, high reliability EX2 with orifice
• Max. allowable pressure PS: 40 bar
• Medium temperature range TS: -40...+65°C

Selection table
Nominal Capacity at 100% Open Valve (kW)*
Type Part No. Description R404A /
R134a R22 R407C R448A R449A R450A R513A R452A
R507
Valve less orifice
EX2-M00 801091
10 mm x 12 mm
13.3 17.2 12.1 18.7 17.2 16.8 11.7 12.0 13.0
Valve less orifice
EX2-I00 801090
3/8“x / 1/2“
EXO-004 801089 Orifice 4 8.5 10.9 7.7 11.8 10.9 10.6 7.4 7.6 8.3
EXO-003 801088 Orifice 3 5.6 7.2 5.1 7.8 7.2 7.0 4.9 5.0 5.5
EXO-002 801087 Orifice 2 3.3 4.3 3.0 4.7 4.3 4.2 2.9 3.0 3.3
EXO-001 801086 Orifice 1 2.5 3.2 2.3 3.5 3.2 3.1 2.2 2.2 2.4
EXO-000 801085 Orifice 0 1.2 1.6 1.1 1.7 1.6 1.6 1.1 1.1 1.2
EXO-00X 801084 Orifice X 0.7 0.9 0.6 1.0 0.9 0.9 0.6 0.6 0.7
Note 1: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
For the selection of other operation conditions, please use Copeland Select software.
Note 2: *) Orifice should be selected at maximum 80% of Qn to allow covering the load fluctuation.

Accessories
Part No.
Type Part No. Description
(Multipack*)

ESC 24V 801033 - Coil 24 VAC / 50 Hz

ESC 230V 801031 - Coil 230 VAC / 50 Hz

ASC-N15 804570 804570M 1.5 m cable length

ASC-N30 804571 804571M Connector Cable Assembly 3.0 m cable length

ASC-N60 804572 - 6.0 m cable length

Plug PG9 801012 -


Plug with cable guide
Plug PG11 801013 -

ESC-K01 801034 - Screw cap (incl. 2x O-ring & fixing retainer)


Note: *) Multipack = 20 pcs

GPC-EN-2024 CONTROLS COMPONENTS 176


Electronic expansion valves series CX2 pulse width
modulated with exchangeable orifices for high-pressure CO2
applications can be used with EC2 display case controllers
Features

• Pulse width modulated


• Shut-off function eliminates the necessity of a separate solenoid valve
• Dampened plunger reduces noise effects of water hammer
• One valve body can be combined with 6 orifices to make 7 capacity
ranges up to 28.2 kW
• Long lifetime, high reliability CX2 with orifice
• Max. allowable pressure PS: 90 bar
• MOPD: 40 bar

Selection Table
Nominal capacity (kW)
Type Part No. Description
at 100% continuous open R 744
CX2-I00 801095 Valve: 3/8” x1/2" ODF 28.2
EXO-004 801089 Orifice 4 17.9
EXO-003 801088 Orifice 3 11.8
EXO-002 801087 Orifice 2 7.0
EXO-001 801086 Orifice 1 5.2
EXO-000 801085 Orifice 0 2.6
EXO-00X 801084 Orifice X 1.5
Note 1: Nominal capacity at -10°C evaporating temperature, +10°C liquid temperature (45 bar) and 1K subcooling.
For the selection of other operation conditions, please use Copeland Select software.
Note 2: The table quotes capacities at 100% duty cycle, i.e. valve is open continuously. However, it is recommended to operate the valve at partial loaded (50-80%) to allow for
system load fluctuations. When used with an EC2 case controller, the valve operates with a 6 second pulse width cycle.
Note 3: CX2 is released as expansion valve and during operation of valve CO2 must be feed in liquid phase to inlet of the valve.

Accessories
Part No.
Type Part No. Description
(Multipack*)

ESC-M24VAC 801304 - Coil 24 VAC / 50 Hz**

ESC-W24VAC 801028 - Coil 24 VAC / 50 Hz**

ESC-W230VAC 801029 - Coil 230 VAC / 50 Hz**

ESC-M230VAC 801027 - Coil 230 VAC / 50 Hz**

ASC-N15 804570 804570M 1.5 m cable length

ASC-N30 804571 804571M Connector Cable Assembly 3.0 m cable length

ASC-N60 804572 - 6.0 m cable length

Plug PG9 801012 -


Plug according to EN 175301 with cable gland
Plug PG11 801013 -

ESC-K01 801034 - Screw cap (incl. 2x O-ring & fixing retainer)


Note: *) Multipack = 20 pcs **) 50Hz coils have lower MOPD with 60Hz frequency.

MOPD levels depending on supply voltage to coil


MOPD Supply voltage to coil Supply voltage to coil
65 bar 24 VAC nominal voltage 230 VAC nominal voltage
60 bar 24 VAC at -5% = 22.8 VAC 230 VAC at -5% = 218.5 VAC
50 bar 24 VAC at -10% = 21.6 VAC 230 VAC at -10% = 207 VAC
45 bar 24 VAC at -15% = 20.4 VAC 230 VAC at -15% = 195.5 VAC
Note: MOPD values are valid only for 50 Hz supply voltage operation.

177 GPC-EN-2024 CONTROLS COMPONENTS


Electrical control valves series EX4-8

Features

• Multifunction as expansion valve, hot gas bypass, suction gas


throttling, head pressure, liquid level actuator etc.
• Fully hermetic design (no thread joints between valve body and
motor compartment)
EX4
• Applicable to all common refrigerants and for subcritical
EX5
CO2 applications
• Stepper motor driven
• Short opening and closing time
• Very fast full-stroke time
• High resolution and excellent repeatability
• Positive shut-off function to eliminate the need for additional
solenoid valve
• Bi-flow versions for heat pump applications
EX6
• High linear flow capacity
• Extremely wide capacity range (10 … 100%)
• Continuous modulation of mass flow, no stress (liquid
hammering) in the refrigeration circuit EX7
• Direct coupling of motor and valve for high reliability (no gear
mechanism)
• Ceramic slide and port for highly accurate flow and minimal wear
• Europe patent No. 0743476, USA patent No. 5735501, Japan
patent No. 28225789
• Balanced force design
• Corrosion resistant stainless steel body and stainless steel
connections EX8

Selection table (Capacities see following page)


Type Part No. Flow Pattern Capacity Range Inlet Connection Outlet Connection Electrical Connection

EX4-I21 800 615 3/8” ODF 5/8” ODF


EX4-M21 800 616 10 mm ODF 16 mm ODF
EX5-U21 800 618 5/8” (16 mm) ODF 7/8” (22 mm) ODF
EX6-I21 800 620 7/8” ODF 1-1/8” ODF
EX6-M21 800 621 22 mm ODF 28 mm ODF
Uni-flow
EX7-I21 800 624 1-1/8” ODF 1-3/8” ODF
EX7-M21 800 625 28 mm ODF 35 mm ODF
EX8-M21 800 629 10 ... 100% 42 mm ODF 42 mm ODF M12 Plug
EX8-U21 800 630 1-3/8” (35 mm) ODF 1-3/8” (35 mm) ODF
EX8-I21 800 631 1-5/8” ODF 1-5/8” ODF
EX4-U31 800 617 5/8” (16 mm) ODF 5/8” (16 mm) ODF
EX5-U31 800 619 7/8” (22 mm) ODF 7/8” (22 mm) ODF
Bi-flow
EX6-I31 800 622 1-1/8” ODF 1-1/8” ODF
(Heat Pump)
EX6-M31 800 623 28 mm ODF 28 mm ODF
EX7-U31 800 626 1-3/8” (35 mm) ODF 1-3/8” (35 mm) ODF

Cable connector assemblies


Connector Type to Driver
Type Part No. Temperature Range Length Connector Type to Valve Illustration
or Controller
EXV-M15 804 663 1.5 m
EXV-M30 804 664 -50 … +80°C 3.0 m M12, 4 Pins Loose Wires
EXV-M60 804 665 6.0 m

GPC-EN-2024 CONTROLS COMPONENTS 178


Capacity data
Nominal capacities…
…as expansion valves and liquid injection valves, (kW) (10%…100%)

R1234ze

R1234yf
R407C

R454C
R410A

R404A

R452A

R448A

R449A

R450A

R513A

R454A

R455A
R452B

R454B
R134a

R507

R124

R744
R22

R23

R32
Type

EX4 19.3 12.8 16.5 11.5 11.5 17.4 17.8 9.2 27.0 12.5 16.5 16.1 11.3 11.5 10.0 22.0 28.6 16.2 13.5 9.2 22.1 15.6

EX5 58.0 39.0 50.0 35.0 35.0 53.0 54.0 28.0 82.0 37.9 50.0 49.0 34.0 35.0 30.0 67.0 87.0 49.0 41.0 28.0 67.0 47.0

EX6 140.0 93.0 120.0 84.0 84.0 126.0 130.0 67.0 197.0 91.0 120.0 117.0 82.0 84.0 73.0 160.0 208.0 118.0 98.0 67.0 161.0 114.0

EX7 385.0 255.0 330.0 230.0 230.0 347.0 357.0 186.0 541.0 250.0 329.0 322.0 225.0 230.0 200.0 441.0 573.0 324.0 270.0 184.0 443.0 313.0

EX8 1027.0 680.0 880.0 613.0 613.0 925.0 495.0 1442.0 666.0 878.0 857.0 600.0 614.0 532.0 1175.0 1528.0 865.0 720.0 491.0 1180.0 833.0
Note 1: Bi-flow versions are not released for use with R124, R452A and R23 refrigerants.
Note 2: Bi-flow versions have identical capacity in both flow directions.

…as hot gas bypass regulator, (kW)

R1234ze

R1234yf
R407C

R454C
R410A

R404A

R452A

R448A

R449A

R450A

R513A

R454A

R455A
R134a

R507

Kv
R22

Type
(m3/h)

EX4 0.2 5.8 2.7 3.9 3.7 3.7 4.4 3.9 4.5 4.4 2.4 2.6 2.0 4.6 3.8 2.3 4.4

EX5 0.7 18.9 8.8 12.7 12.2 12.2 14.2 12.8 14.5 14.2 7.6 8.6 6.5 15.0 12.4 7.5 14.4

EX6 1.6 44.0 20.4 29.5 28.3 28.3 33.0 29.7 33.8 33.1 17.7 19.9 15.1 34.9 28.7 17.4 33.4

EX7 5.6 156.0 73.0 105.0 100.0 100.0 117.0 105.0 120.0 118.0 63.0 71.0 54.0 124.0 102.0 62.0 119.0

EX8 17.0 475.0 220.0 319.0 305.0 305.0 356.0 320.0 364.0 358.0 192.0 215.0 163.0 376.0 310.0 188.0 361.0
Note: Bi-flow versions are not released for hot gas flow applications.

…as suction pressure regulator (evaporator or crankcase), (kW)

R1234ze

R1234yf
R407C

R454C
R410A

R404A

R452A

R448A

R449A

R450A

R513A

R454A

R455A
R134a

R507

Kv
R22

Type
(m3/h)

EX6 1.57 5.0 3.1 4.1 3.5 3.6 3.9 3.4 3.9 3.8 2.8 3.0 2.5 4.0 3.4 2.7 3.5

EX7 5.58 17.9 11.1 14.7 12.5 12.7 13.7 12.1 13.8 13.6 9.9 10.6 9.0 14.1 12.0 9.6 12.6

EX8 16.95 54.5 33.6 44.5 38.1 38.6 41.8 36.8 41.9 41.4 30.1 32.2 27.4 42.9 36.4 29.1 38.2

Note: Bi-flow versions are not released for use below -40°C

…as condensing pressure regulator and liquid duty, (kW)


R1234ze

R1234yf
R407C

R454C
R410A

R404A

R452A

R448A

R449A

R450A

R513A

R454A

R455A
R134a

R507

Kv
R22

Type
(m3/h)

EX4 0.21 5.7 5.6 6.0 4.0 3.9 5.7 4.1 5.3 5.2 5.3 5.0 5.1 5.1 4.5 4.2 4.8

EX5 0.68 18.5 18.3 19.5 12.9 12.5 18.5 13.2 17.1 16.8 17.0 16.3 16.5 16.5 14.7 13.6 15.6

EX6 1.57 43.0 42.5 45.5 30.0 29.1 43.0 30.7 39.9 39.1 39.6 37.8 38.3 38.5 34.3 31.6 36.2

EX7 5.58 153.0 151.0 162.0 107.0 103.0 153.0 109.0 142.0 139.0 141.0 134.0 136.0 137.0 122.0 112.0 129.0

EX8 16.95 465.0 459.0 491.0 324.0 314.0 464.0 331.0 430.0 422.0 428.0 408.0 413.0 415.0 370.0 341.0 391.0

…for hot gas flow such as heat reclaim application, (kW)


R1234ze

R1234yf
R407C

R454C
R410A

R404A

R452A

R448A

R449A

R450A

R513A

R454A

R455A
R134a

R507

Kv
R22

Type
(m3/h)

EX5 0.68 5.9 4.0 5.1 4.3 4.3 5.1 4.4 5.1 5.0 3.7 3.8 3.3 5.2 4.5 3.4 5.0

EX6 1.57 13.7 9.3 11.8 9.9 9.9 11.8 10.1 11.7 11.6 8.5 8.8 7.6 11.9 10.4 7.7 11.4

EX7 5.58 48.8 32.9 42.1 35.3 35.3 42.1 36.1 41.7 41.1 30.1 31.2 27.1 42.3 37.1 27.5 40.6

EX8 16.95 148.0 100.0 128.0 107.0 107.0 128.0 110.0 127.0 125.0 91.0 95.0 82.0 129.0 113.0 84.0 123.0
Note: Bi-flow versions are not released for hot gas flow applications.

179 GPC-EN-2024 CONTROLS COMPONENTS


The nominal capacity is based on the following conditions:
Evaporating Condensing Pressure drop Pressure drop Pressure drop Isentropic efficiency
Refrigerant
temperature temperature (For suction duty (For liquid duty) (For hot gas flow duty) (For hot gas flow duty)
R134a, R404A,
+38°C bubble &
R410A, R513A, +4°C dew point
dew point
R1234ze
+38°C bubble/
R407C +4°C dew point
+43°C dew point
R124 +20°C +80°C
R23 -60°C -25°C
0.15 bar 0.35 bar 0.5 bar 80%
R744 -10°C +10°C
+38°C bubble/
R450A
+38.6°C dew point
+38°C bubble/
R452A +4°C
+41.6°C dew point
+38°C bubble/
R448A, R449A
+42.6°C dew point
Note: For selection of other operating condition, please use Copeland Select software.

Technical data
A1: R134a, R404A, R507, R407C,
Evaporating Temperature -100…+55°C
R450A, R513A, R452A, R448A,
Compatibility R449A, R410A, R744 (subcritical),
Salt Spray Test non-corrosion stainless steel body
R23, R124
Note: UL only for use with A1 Connections ODF stainless steel fittings
refrigerants. A2L: R32, R452B, R454B, R454A,
R454C, R1234ze, R1234yf Humidity 5 to 95% r.H.
Mineral and POE lubricants
Protection accordance to IEC IP67 with Copeland supplied cable
MOPD EX4/EX5/EX6: 40 bar 529, DIN 40050 connector assembly
(Maximum Operating EX7: 35 bar
Pressure Differential) EX8: 30 bar Vibration for non-connected 4g
and fastened valve (0…1000 Hz, 1 octave /min.)
EX4 (uni-flow): 90 bar
EX4(bi-flow)/EX5/6/7: 60 bar 20 g at 11 ms
Shock
Max. allowable pressure PS EX8: 45 bar 80 g at 1 ms
UL Approval: EX4/5/6/7: 60 bar 0.5 kg (EX4), 0.52 kg (EX5),
UL Approval: EX8: 45 bar Net weight (kg) 0.60 kg (EX6), 1.1 kg (EX7),
EX4 (uni-flow): 99 bar 1.5 kg (EX8)
EX4(bi-flow)/EX5/6/7: 66 bar
Factory test pressure PT External leakage ≤ 3 g / year
EX7: 86 bar
EX8: 65 bar Positive shut-off better than
Seat Leakage
Ambient temperature -40…+55°C solenoid valves
Storage temperature -40…+70°C Marking
Medium Inlet Temperature EX4/5/6: None (Out of PED scope)
Bi-flow version: TS: -50…+80°C EX7/8: 1017 (Module D1) UKCA
Uni-flow version: TS: -50…+100°C
(UL-Approval based on ≥ -40°C) EX4/5/6/7/8:

Electrical data
Bi-polar, phase current by chopper EX4/EX5/EX6: 30 mH ± 25%
Stepper Motor Type
control (constant current) Phase Inductance EX7: 20 mH ± 25%
Electrical Connection 4 pin terminal via plug EX8: 22 mH ± 25%

Recom. Driver Supply 24 VDC (nominal) Step Mode 2 phase full step

Driver Supply Step Angle 1.8° per step ± 8%


18…36 VDC
Voltage Range Mechanical stop at fully close
Reference Position
EX4/EX5/EX6: 500 max, -10% position
Phase Current, Operating EX7: 750 mA ±10% EX4/EX5/EX6: 750 full steps
EX8: 800 mA ±10% Total Number of Steps EX7: 1600 full steps
EX8: 2600 full steps
EX4/EX5/EX6: 100 mA
Holding Current EX7: 250 mA EX4/EX5/EX6: 14 Ω ±10%
EX8: 500 mA Winding Resistance per Phase EX7: 10 Ω ±10%
EX8: 7.5 Ω ±10%
Nominal Input Power EX4/EX5/EX6: 3.5 W
EX4/EX5/EX6: 1.5 seconds
per Phase EX7/EX8: 5 W
Full Travel Time EX7: 3.2 seconds
Stepping Rate 500 Hz EX8: 5.2 seconds

GPC-EN-2024 CONTROLS COMPONENTS 180


High pressure expansion valves series CV4-6.5
CV4-6.5 valves are stepper motor driven valves for precise control of
refrigerant mass flow in air conditioning and refrigeration systems with CO2.
The control valves can be used as high pressure gas valve for gas cooler
control, expansion device, hot gas and cold gas bypass, liquid injection
duty, evaporator pressure regulator, crankcase pressure regulator, head
pressure regulator, or liquid level control.

Features and benefits

• Maintenance free
• Multifunction
• Fully hermetic design with ODF connections
• Stepper motor driven CV4-6.5
• Short opening and closing time with ODF connection
• Very fast full stroke time
• High resolution and excellent repeatability
• Positive shut-off function to eliminate the use of an additional solenoid valve
• Linear flow capacity
• Extremely wide capacity range (10…100%)
• Optimal solution applied to offer the highest reliability and lifespan,
accordingly to the high differential pressures in the CO2 systems
• Ceramic slide and port for precise flow and minimal wear
• Balanced force design
• Corrosion resistant stainless-steel body and connections

Selection table
Kv Electric
Type Part No. Control Range Inlet Connection Outlet Connection
(m3/hr) Connector
CV4-HPV 802056 0.2 3/8" 5/8"
CV5-HPV 802057 0.6 5/8" 7/8" M12 plug
Please refer
CV6-HPV 802058 1.5 to Copeland 7/8" 1-1/8"
CV4.5-HPQ 802060 0,45 Select 5/8” 5/8”
software.
CV5.5-HPQ 802061 0,85 7/8” 7/8"
CV5.8-HPQ 802062 1,30 7/8” 7/8”
Note 1: Valves are delivered without cable/connector assembly. Please order them separately.

Cable and connector assemblies


Connector type
Temperature Connector type
Type Part No. Length to driver board or Illustration
Range to valve
controller
EXV-M15 804 663 1.5 m
EXV-M30 804 664 -50 … +80°C 3.0 m M12 Loose wires

EXV-M60 804 665 6.0 m

Technical data CV valves


Marking Protection Accordance to IP67 with EXV-Mxx plug and
not required (Out of scope of PED) IEC 529, DIN 40050 cable assembly

CV4/5/6 (No.MP604) Vibration 4 g (0…1000 Hz, 1 octave /min.)

Compatibility CO2 and POE lubricants 20 g at 11 ms


Shock (CV4-6)
80 g at 1 ms
70 bar
MOPD
(In conjunction with EXD-U02 driver) External Leakage 6.4*10-6 mbar*liter/sec.
Max. Allowable Pressure PS 130 bar Humidity 100% R.H.
Factory Test Pressure PT 186 bar
Temperatures
-40…+65°C
Ambient
-40…+70°C
Storage
-50…+100°C
Medium

181 GPC-EN-2024 CONTROLS COMPONENTS


Electrical data CV valves
Bi-polar, phase current
Step Mode 2 phase full step
Stepper Motor Type by chopper control (constant
current)
Stepping Rate 500 Hz
Electrical Connection 4 pins terminal for M12 plug
CV4-6: 750 full steps
Driver Supply Voltage to the Total Number of Steps
18…36 VDC CV7: 6400 full steps
Valve
Operating (Moving) CV4: 625 mA Winding Resistance CV4: 14 Ω ±10%
Current Peak CV5-7: 800 mA per Phase CV5-7: 10 Ω ±10%
CV4: 100 mA CV4-6: 1.5 s
Holding Current Peak Full Travel Time
CV5-7: 300 mA CV7: 12.8 s

CV4: 30 mH ± 25% Mechanical stop at


Phase Inductance Reference Position
CV5/6/7: 20 mH ± 25% fully close position

GPC-EN-2024 CONTROLS COMPONENTS 182


183 GPC-EN-2024 CONTROLS COMPONENTS
Electronic controllers and sensors

Selection table electronic controllers


Network Communication
Description
Without Modbus
Superheat Controllers and Stepper Motor Drivers
Universal Stepper Driver Module for Electrical Control Valves EX4-8 EXD-U02
Superheat Controller for Electrical Control Valves EX4-8 EXD-SH1/2
Superheat Controller for Electrical Control Valves EXM/L, EXN EXD HP1/2
Economizer Controller for Tandem Compressors
Enhanced Wet Vapor Injection with EXM/L EXD TEVI
Pressure Transmitter
Output Signal 4 … 20 mA PT5N
Temperature Sensors
NTC TP1-NP..
PT1000 ECN-Z.. / ECP-P..
Compressor Soft Starter
For Single Phase Compressor Motors with Up to 32 A CSS
Electronic Fan Speed Controllers
Pressure Actuated, Current Range 0.1 … 4 A FSY/FSM
Fan Speed Control Modules for EC-Type Motors FSE

Electronic superheat controllers Sensors


and stepper motor drivers
PT5N series pressure transmitters are used to measure the suction
Copeland designs superheat controllers and valve drivers
and discharge pressures to modulate the compressor and fan
for stepper motor driven control valves for all commercial
capacities.
refrigeration and air conditioning applications.
ECN, ECP, TP1 Temperature sensors (NTC/PT1000) are used to
The EXD-U02 universal driver can be connected to any measure the suction and discharge temperatures.
controller which can provide a 4-20 mA or 0-10 V analogue
signal. The output is the opening/closing of EX4-8, CV4-6.5 and
consequently the control of the refrigerant liquid or vapor mass
flow in accordance with the analogue input.

EXD-SH1/2, EXD-HP1/2 and EXD-TEVI are superheat controllers


and or economizer controllers with Modbus communication.

GPC-EN-2024 CONTROLS COMPONENTS 184


EXD-SH1/2 controller for EX/CV with
ModBus communication capability
EXD-SH1/2 are stand-alone universal superheat and or temperature
controllers for air conditioning units or refrigeration systems.

Features
• EXD-SH1: Control of one valve
• EXD-SH2: Control of two valves in two independent circuits
• Main function
Circuit 1 Circuit 2
EXD-SH1 Superheat or Temperature Control
EXD-SH2 Superheat or Temperature Control Superheat Control

• Other functions: Limitation of evaporating pressure (MOP),


Low pressure switch, freeze protection and manual
positioning of valve(s)
• Self-adapting superheat control function in conjunction with
Copeland EX4-8 & CV4-6.5
• For multiple refrigerants, including ultralow temperature EXD-SH2
refrigerant R23 (only with ECN-Z60)
• Released for applications using A2L and A3 refrigerants
• Modbus (RTU) communication
• EXD-SH2: capability the operation of two evaporator/ EXV /
Pressure sensor with single pressure transmitter
• Integrated keyboard with two lines display
• Monitoring of sensors and detection of sensor
(ECN-Z.../TP1-.../PT5N-...) stepper motor wiring failures
• Optional upload/download key (accessory) for transmission of
parameter settings among controllers with the same setting EXD-M03
• Low/high superheat alarm as well as other function alarms
• Electrical connection via plug-in type screw terminals included with
controller and Micro Molex EXD-M03 (must be ordered separately)
• DIN rail mounting housing

185 GPC-EN-2024 CONTROLS COMPONENTS


Selection table
Type Description Part No.
Controllers Multipack (25 pieces) Single Pack
EXD-SH1 Controller for single refrigeration circuit - 807 855
EXD-SH2 Controller for two independent refrigeration circuits - 807 856
EXD-M03 Molex terminal with 3 meter wires - 807 865
Temperature Sensors Multipack (20 pieces) Single Pack
TP1-NP3 Temperature sensor with 3 meter cable 804489M 804 489
TP1-NP6 Temperature sensor with 6 meter cable 804490M 804 490
TP1-NP12 Temperature sensor with 12 meter cable 804491M 804491
ECN-Z60 Ultralow temperature sensor with 6 meter cable - 807 826
Pressure Transmitters: PT5N (7/16-20UNF Connection) Multipack (25 pieces) Single Pack
PT5N-07M Sensing pressure range -0.8...7 bar 805350M 805350
PT5N-18M Sensing pressure range 0...18 bar 805351M 805351
PT5N-30M Sensing pressure range 0...30 bar 805352M 805352
PT5N-50M Sensing pressure range 0...50 bar 805353M 805353
PT5N-150D Sensing pressure range 0...150 Bar (1/4 NPTF) 805379M 805379
Pressure Transmitters: PT5N (Brazing Connection) Multipack (25 pieces) Single Pack
PT5N-07T Sensing pressure range -0.8...7 bar 805380M 805380
PT5N-10P-FLR Sensing pressure range -0.8…10 bar 805391M 805391
PT5N-18T Sensing pressure range 0...18 bar 805381M 805381
PT5N-30T Sensing pressure range 0...30 bar 805382M 805382
PT5N-50T Sensing pressure range 0...50 bar 805383M 805383
PT5N-30P-FLR 805389M 805389
PT5-30L-FLR Sensing pressure range 0...30 bar 802389M 802389
Note: Pressure range 18 bar for system with R410A, 30 bar for R410A economizer, 50/150 bar for CO2

Accessories
Type Description Part No.
M12 Plug And Cable For Pressure Transmitters PT5N Multipack (20 Pieces) Single Pack
PT4-M15 1.5 m 804803M 804803

PT4-M30 3.0 m 804804M 804804

PT4-M60 6.0 m 804805M 804805

PT4-M10 FLR 1.0 m cable length, 2-wire, ATEX certified 804801M 804801

PT4-M15 FLR 1.5 m cable length, 2-wire, ATEX certified 804802M 804802

PT4-M60-FLR 6.0 m cable length, 2-wire, ATEX certified 804806

Uninterruptible Power Supply

ECP-024 Backup battery with two outputs for two controllers - 804558

K09-P00 Electrical terminal kit for ECP-024 - 804 560


Super cap for only EXD-SH1
EXD-PM - 807 854
(Two pieces of EXD-PM required for one EXD-SH2)

Available configuration options


Selectable Valves

EX4-8 CV4-6.5

R11, R134a, R507, R404A, R407C, R410A, R124, R744, R407A, R407F, R23,
Refrigerants R32*, R1234ze*, R448A, R449A, R450A, R513A, R290*, R1270*, R454C*, R744 (CO2)
R452B*, R454B*, R454A, R452A, R444B*, R455A*, R1233zde, R1234yf

Main Function Superheat or and temperature control

Pressure Transmitters PT5N or 3rd party ratio metric

Note: *) EXD-SH1/2 is not ATEX approved.

GPC-EN-2024 CONTROLS COMPONENTS 186


Technical data: EXD-SH1/2
Supply Voltage 24 VAC/DC ±10%, 50/60 Hz Mounting DIN Rail Mounted
EXD-SH1: Max. 25 VA
Power Consumption Accessory
EXD-SH2: Max. 50 VA Type: EXD-M03
(12 Poles Molex Plug with
(to be Ordered Separately)
Terminals 1 to 12 Suitable for 12 Poles Molex Plug 3 Meter Cable)
Suitable for Removable Screw
Terminals 13 to 36 Version: Wire Size 0.14 … 1.5 mm2
Included in Controller Delivery
Protection Class IP 00

Marking

Optional EXD-PM supercap


Supply Voltage 24 VAC/DC ±10%, 50/60 Hz Protection Class 24 VAC/DC ±10%, 50/60 Hz
Output Voltage 12 VDC
Mounting 12 VDC
-1.2 A
Max. Output Current
-350 mA during charging Temperatures
Power Consumption 12 VA Storage -20…+70°C
Suitable for removable screw Operating/Surrounding -10…+60°C
Terminals
version: wire size 0.14…1.5 mm2 Housing Self-extinguishing ABS
Suitable for one EXD-SH1 20…85%
Output: to Driver/Controller Relative Humidity
Two EXD-PM for one EXD-SH2 non-condensing

Charging Time 60 seconds Marking

Max. Cable Length Between 50 cm


EXD-PM and EXD-SH1/2 AWG18 wire size Weight 125 g

Optional uninterruptible power supply ECP-024

Backup Battery Type Lead acid gel rechargeble battery Protection Class IP 20
Mounting DIN rail mounted
Number of Backup Batteries 2, each 12 VDC, 0.8 Ah
Temperatures
Storage -20…+65°C
Supply Voltage 24 VAC+-10%, 50-60 Hz Operating/Surrounding -10…+60°C
Housing Aluminum
Output Voltage, UB 18 VDC
< 90%
Relative Humidity
non-condensing
Number of Outputs to Drivers 2
Screw terminals
Connection
for wire size 0.5…2.5 mm2
Battery Recharge Time Approximately 2 hours
K09-U00
Accessories: Terminals
Part No: 804559
Marking
Weight 1200 g

Input, output EXD-SH1/2


Description Specification

Analogue Input(s): NTC Temperature Sensor TP1-N... (-45...+150°C operating range)


Analogue Input: PT1000 Temperature Sensor ECN-Z60 (-80 … -40°C sensing range)

Analogue Input(s): 4...20 mA Pressure Transmitters PT5N


Analogue Input(s): 0.5...4.5 V Pressure Transmitters Third Party Ratio Metric Pressure Transmitters (Total Error: ≤ 1%)

Digital input(s) Dry Contact, Potential Free

Digital output(s): Alarm Relay(s)


Resistive Load 24 V AC/DC, Max. 1 A
Contact is closed: During Alarm Condition
Inductive Load 24 V AC, Max. 0.5 A
Contact is open: During Normal Operation and Supply Power OFF

Communication RS485 RTU Modbus, Two Wires

187 GPC-EN-2024 CONTROLS COMPONENTS


EXD-HP1/2 stand-alone superheat/economizer controller
EXD-HP1/2 are stand-alone universal superheat and or economizer controllers
for heat pumps, heating units, air conditioning and precision cooling such as
telecom and shelter applications.

Features
• Self adapting superheat/economizer control in conjunction with Copeland stepper motor
driven electronic expansion valves EXM/EXL
• Discharge hot gas temperature control by liquid/vapor injection to compressor
• EXD-HP1: Controller with one EXV output
• EXD-HP2: Controller with two independent EXV outputs
• Controllers as slave with Modbus (RTU) communication capability. All data (read/write)
accessible by any third party controller having modbus communication (RTU)
• Upload/download key (accessory) for transmission of parameter settings among controllers
with the same setting
• Released for applications using A2L and A3 refrigerants
• Low pressure switch and freeze protection function
• Manual positioning of valve(s)
• Limitation of evaporating pressure (MOP)
• Low/high superheat alarm
• Monitoring of sensors and sensor wiring / detection of sensor and wiring failures
EXD-HP2
• Integrated display (3-digit LEDs) and keyboard
• Electrical connection via plug-in type screw terminals (included with controller)
• DIN rail mounting housing

Selection table
Part No.
Type Description Multipack (20 pieces)
Multipack (20 pieces)
Single pack
EXD-HP1 with 1 EXV output 807836M -
EXD-HP2 with 2 EXV outputs 807837M -
Valves / coils
EXM-B0A 800399M -
EXM-B0B 800400M -
Electronic expansion valve
EXM-B0D 800401M -
EXM-B0E 800402M -
EXM-125 Coil 12 VDC 800403M -
EXL-B1F 800405M -
Electronic expansion valve
EXL-B1G 800406M -
EXL-125 Coil 12 VDC 800407M -
EXN-B2K Electronic expansion valve - 800421
EXN-B2L (not selectable in conjunction with R290) - 800422
EXN-125 Coil 12 VDC - 800420
Temperature sensor
ECP-P30 Temperature sensor with 3 m cable - 804495
Suction pressure (refrigerant)
PT5N-07M / PT5N-07T -0.8…7 bar 805350M / 805380M 805350 / 805380
PT5N-10P-FLR -0.8…10 bar 805391M 805391
PT5N-18M / PT5N-18T 0...18 bar 805351M / 805381M 805351 / 805381
PT5N-30M / PT5N-30T 0...30 bar 805352M / 805382M 805352 / 805382
PT5N-30P-FLR 805389M (25 pcs) 805389
PT5-30L-FLR Sensing pressure range 0...30 bar 802389M 802389
Plug and cable assembly for pressure sensors
PT4-M15 1.5 m cable length 804803M 804803
PT4-M30 3.0 m cable length 804804M 804804
PT4-M60 6.0 m cable length 804805M 804805
PT4-M60-FLR 6.0 m cable length, 2-wire, ATEX certified - 804806

GPC-EN-2024 CONTROLS COMPONENTS 188


Application as air to water heat pumps: heating and cooling

Technical data Input sensors, output valves


Supply Voltage 24 VAC/DC ±10% Description Specification
EXD-HP1: Max. 15 VA
Power Consumption ECP-P30 (3 meter cable length)
EXD-HP2: Max. 20 VA Temperature Input
Range: -30°C…+150°C
EXD-HP1: Two, each potential free
Digital Inputs
EXD-HP2: Three each potential free PT5N
SPDT contacts, AgSnO Pressure Sensor Input
Signal: 4 … 20 mA
Relay Output Inductive (AC15) 24 VAC : 1 A
Resistive: 24 VAC/DC: 4 A
Removable screw version
Plug-In Connector Size
wire size 0.14…1.5 mm2

Protection Class IP 20
Mounting DIN Rail Mounted

Marking

189 GPC-EN-2024 CONTROLS COMPONENTS


EXD-TEVI economizer controller for tandem compressors
EXD-TEVI is a stand-alone controller for enhanced wet vapor injection
for Copeland scroll tandem compressors in heating applications.

Features

• Copeland solution for specified operating map of tandem scroll


• Two EXL valves can be driven in parallel for required wide
injection capacity
• Input signals: Injection (intermediate) pressure and temperature
sensor as well as two compressor discharge temperature sensors
• Two independent digital inputs for recognition of tandem
compressors operation
• High discharge temperature alarm
• Monitoring of sensors and sensor wiring and detection of sensor
wiring failures
• Controllers as slave with Modbus (RTU) communication capability
• Upload/download key (accessory) allows to copy parameter
settings from one controller to others
• Integrated 31/2 digit 7-segment display with 6 indicator LEDs
• Electrical connection via plug-in type screw terminals
(included with controller)
EXD-TEVI

Selection table
Part No.
Type Description
Multipack Single pack
Controller
EXD-TEVI Controller with connectors 807838M 807838
Temperature Sensors
TP1-NP3 Temperature sensor with 3 m cable 804489M (20pcs) 804489
TP1-NP6 Temperature sensor with 6 m cable 804490M (20pcs) 804490
TP1-NP12 Temperature sensor with 12 m cable 804491M (20pcs) 804491
Pressure transmitters: PT5N
PT5N-30M Sensing pressure range 0…30 bar (7/16-20UNF connection) 805352M 805352
PT5N-30T Sensing pressure range 0…30 bar (Brazing connection) 805382M 805382
Plug and cable assembly for pressure transmitters
PT4-M15 1.5 m cable 804803M 804803
PT4-M30 3 m cable 804804M 804804
Electronic expansion valve with coils
EXL-B1F 800405M -
Valve body
EXL-B1G 800406M -
EXL-125 coil for EXL 12 VDC 800407M -

Technical data
Supply Voltage 24 VAC/DC ±10% Protection Class IP 20
Power Consumption EXD-TEVI: Max. 20 VA
Mounting DIN Rail Mounted
Digital Inputs 2 (Potential Free)
SPDT, with AgSnO Contacts
Relay Output (Alarm) Inductive (AC15) 24 V AC: 1 A Marking
Resistive: 24 V AC/DC: 4 A
Removable Screw Version
Plug-In Connector Size
Wire Size 0.14 … 1.5 mm2

Technical data: sensors


Description Specification
1 x 10k NTC for Injection Line Temperature (TP1-N...)
Temperature Sensors
2 x 86k NTC for Discharge Gas Temperature (Part of Compressor Delivery)
Pressure Transmitter EVI PT5N-30M/T: 4...20 mA (Range: 0...30 bar)

GPC-EN-2024 CONTROLS COMPONENTS 190


Universal driver modules series EXD-U02
Stepper motor valve driver specifically designed for the EX and CV series of
electrical control valves in applications such as:
• Capacity control by means of hot gas bypass
• Evaporating pressure regulator or crankcase pressure regulator
• Hot gas flow such as heat reclaim
• Condensing pressure regulation and liquid duty
• Refrigerant mass flow control in CO2 transcritical systems

Features
• Plug and play, no parameter setting
• Valve opening proportional to 4...20 mA or 0...10 V EXD-U02
analogue input signal
• Digital input can be used to force valve closing Options
• Easy configurable by dip-switches
• Easy wiring • Uninterruptible power supply ECP-024 to automatically
• Fully tested and ready for operation close valve after power down

Selection table
Type Part No. Description
EXD-U02 804752 Universal Driver Module K09-U00
EXD-U02 Contr. Kit 808053 Universal Driver Module with Terminal Kit
K09-U00 804559 Terminal Kit for EXD-U01

Accessories ECP-024 K09-P00


Type Part No. Description
ECP-024 804558 Uninterruptible power supply for up to 2 drive modules
K09-P00 804560 Electrical terminal kit for ECP-024
ECT-323 804424 Transformer 25 VA ECT-323 ECT-623
ECT-623 804421 Transformer 60 VA 24V/230 VAC – DIN-rail mounting

Function
The driver module EXD-U02 requires an analog input signal of 4…20 mA or 0…10 V. The output is the closing/opening of EX/CX valve
series and consequently the control of liquid or vapor refrigerant mass flow in accordance with the analog input. The universal driver
module can be connected to any controller which can provide a 4…20 mA or 0…10 V analog signal. This gives extreme flexibility to
system manufacturers to use any desired controller and achieve different functionalities. The universal driver module keeps the valve at
fully close position when the input signal is 4 mA or 0 V. The valve will be fully open at 20 mA or 10 V.

Optional uninterruptible power supply ECP-024


The optional uninterruptible power supply ECP-024 contains a rechargeable lead-acid battery, which provides enough energy to close
the valve in case of power loss. ECP-024 can be connected to two EXD-U01 Driver Modules for closure of up to two valves.

Technical data
24 VAC ±10%, 50-60 Hz Analog Input Signal 4...20 mA
Note: 24 VDC supply voltage can be used but Burden 364 Ω
Supply Voltage
it results to lower MOPD and it needs to be
verified by system manufacture. Analog Input Signal 0...10 V
Impedance 27 kΩ
Supply Current To be protected by a 1.0 A external fuse
24 VAC ±10%, 50-60 Hz
Power Consumption 10 VA in conjunction with EXV Digital Input
24 VDC ±10%
Protection Class IP20 Screw terminals
Connector
Weight 800 g for wire size 0.5...2.5 mm²
Mounting DIN rail mounted
Marking
Housing Aluminum

Optional uninterruptible power supply ECP-024


Backup Battery Type Lead acid gel rechargeable battery Screw terminals
Connection
Number of Backup for wire size 0.5...2.5 mm2
2, each 12 VDC, 0.8 Ah
Batteries Mounting DIN rail mounted
Supply Voltage 24 VAC ±10%, 50-60Hz
Protection Class IP20
Output Voltage, UB 18 VDC
Housing Aluminum
Number Of Outputs 2
to Drivers

Marking

191 GPC-EN-2024 CONTROLS COMPONENTS


Compressor soft starter CSS-25U / CSS-32U
The compressor soft starter CSS-25U / CSS-32U is used for
switching, protecting and starting current limitation of single
phase compressors in residential heat pump applications.

Features
• For motors with maximum operating current up to 25 A/32 A
• Limitation of starting current to less than 45 A
(Part No. 805209 less than 30 A)
• Self-adjusting for use in 50 Hz or 60 Hz supply
• Self-adjusting to motor current - no manual adjustment or
calibration necessary CSS-32W
• Alarm relay output
• Start capacitor for improved motor acceleration is switched off Standards:
after start • LVD 2014/35/EU Low Voltage Directive
• Low voltage shutdown • EN 60947-1 Low voltage switchgear and controlgear
• Locked rotor recognition and shutdown • EN 60947-4-2 Contactors and motor-starters - AC semiconductor
• Delay function to limit number of motor starts per hour motor controllers and starters
• Thyristor protected contactor for long life • EN 60335-1, EN 60335-2-40: Safety of household and similar
• No extra motor contactor needed electrical appliances (Part No. 805 204 and 805 205 only ,
• Self-diagnostics confirmed and certified by independent test lab VDE.)

• Mounting clip for easy installation allows DIN rail mounting in • EMC 2014/30/EU
two directions • ROHS 2011/65/EU
• Easy connection by cage type screw terminals wire Ø 4 mm

Selection table
Type Part No. Part No. (20 pieces) Description I max

CSS-32U 805212 805212 M Soft Starter Incl. Mounting Clip, VDE Released Version 32 A

CSS-25U 805213 805213 M Soft Starter Incl. Mounting Clip, VDE Released Version 25 A

CSS-25U 805214 805214 M Soft Starter Incl. Mounting Clip (limitation of starting current to less than 30 A) 25 A

K00-003 807663 - 3-pol screw connector to alarm output for wires up to 2.5 mm2; bag with 50 pieces

Technical data
Operating Voltage 230 V 50/60 Hz Nominal Alarm Relay, AgNi (SPDT)
250 V~ / 3 A
Nominal Compressor CSS-32U: 32 A Max.
Resistive (AC1) Max. 30 V= / 3 A
Current CSS-25U : 25 A Max.
Flexible Cable Cross Section
CSS-32U: 45 A
Maximum Start Current CSS-25U (805 205): 45 A CSS-32U/-25U All Terminals 0.25 … 4 mm2
CSS-25U (805 209) 30 A Flexible Cable Cross Section
Operating Temperature -20 ... +55°C Non Condensing Alarm Output Connector K00-003 0.25 … 2.5 mm2
Storage Temperature -20 ... +65°C Non Condensing Max. Vibration (At 10 … 1000 Hz) 4g

Start Capacitor 200 ... 240 uF Weight 430 g

Time Delay After Stop 0.5 … 5 Min Protection Acc. IEC 529 IP 20

Wiring diagram CSS contacts


R = Output Motor Run Winding
RC = Output Run Capacitor
L = 230 V / AC Power Input
N = Neutral Line
Uc = Start Input (ON if Connected to 230 V)
S = Output Start Winding from Start Capacitor
A1, AC, A2 = Alarm Relay Contact

GPC-EN-2024 CONTROLS COMPONENTS 192


Pressure transmitter PT5N
PT5N pressure transmitters convert a pressure into a linear
electrical 4...20 mA output signal suitable for controlling simple
compressor and fan switching to the more sophisticated
application of superheat modulation of electronic control valves.

With competitive performance to price characteristics and


an easy to install pre-fabricated M12 cable assembly, PT5N
transmitters are the designers choice for all heat pump,
refrigeration and air conditioning applications.

Features PT5N-30M PT5N-30T


• Piezo-resistive sensor with output signal 4...20 mA and
2-wire connection for the precise operation of superheat,
compressor or fan control systems
• Specially calibrated pressure ranges with ±1% accuracy
performance to fulfill demands of today’s refrigeration and
HVAC applications
• Fully hermetic
• PT5N-xxM with 7/16”-20UNF pressure connection and
Schrader valve opener
• PT5N-xxT with 40 mm stainless steel tube and integrated
brazing neck for easy mounting in applications requiring a
fully hermetic system solution
• PT5N-150D for subcritical and transcritical CO2 systems
• Vibration, shock and pulsation resistant
• Protection class IP65 / IP67 (type-specific)
• UL (File No. E499688)

Selection table
Part No. Medium
Pressure Range
Output Temp. Range at Max. Allowable Test Pressure Burst
For Signal Pressure
Type Signal Pressure Pressure PS PT Pressure
Output Connection
Single Pack MultiPack** (mA) Connection (bar) (bar) (bar)*
(bar)*
(°C)
PT5N-07M 805350 805350M -0.8 .. 7 27 30 150 7/16” – 20
UNF
PT5N-18M 805351 805351M 0 .. 18 48 63 250 (with
PT5N-30M 805352 805352M 0 .. 30 60 100 400 Schrader
Valve
PT5N-50M 805353 805353M 0 .. 50 75 150 400 Opener)
PT5N-07T 805380 805380M -0.8 .. 7 4 .. 20 -40 .. +135 27 30 150
PT5N-18T 805381 805381M 0 .. 18 48 63 250
6 mm ODM
PT5N-30T 805382 805382M 0 .. 30 60 100 400
PT5N-50T 805383 805383M 0 .. 50 75 150 400
PT5N-150D 805379 - 0 .. 150 150 320 1000 ” NPT (male)

Note: *) Sealed Gauge Pressure


**) 25 pcs

Selection table plug/cable assemblies: assembly fits all models


Part No. Cable Weight
Type Temperature Range
Single Pack Multi Pack* Length (g/Piece)

PT4-M15 804 803 804 803M 1.5 m 50


-50 ... +80°C Static Application
PT4-M30 804 804 804 804M 3.0 m 80
-25 ... +80°C Mobile Application
PT4-M60 804 805 804 805M 6.0 m 140
Note 1: *) 20 pieces
Note 2: PT4-M... are not in compliance with EN60335-1/2-40, clause 30 in term of glue wire test however, they comply to EN60079-15, clause 22.3 heat endurance test.

193 GPC-EN-2024 CONTROLS COMPONENTS


Technical data pressure transmitter

Supply Voltage Nominal: 24 VDC 30 Million Load Cycles with 1.3 Times of
(Polarity Protected) Range: 7.. 33 VDC Sensor Lifetime
Nominal Pressure

A1: R134a, R410A, R407C,


Electrical Connection M12 Connection according to
R404A, R507, R448A, R449A,
IEC 61076-2-101:2012
R513A,R450A,R452A, R23, R124,
Medium Compatibility PT4-Mxx Cable Assembly Prefabricated, various cable lengths
R744

A2L: R32 acc. EMC Directive


(EN 61326-2-3)
Approvals/Marking
Maximum ≤ 23 mA cULus(LISTED)
Operating Current
4...20 mA Output (UL File Nr. 499688) pending

IP67 with mounted plug and cable


RL ≤ Ub - 7.0 V Protection Class (EN 60529)
Load Resistance assembly
0.02 A

Vibration at 15...2000Hz 20 g according to IEC60068-2-6


Response Time ≤ 2 ms

Materials Stainless steel 1.4404 / AISI316L


Temperatures Housing
Transport and Storage -50 .. +100 °C
Operating Ambient Housing -30 .. +85°C Pressure Connection Stainless steel 1.4301 / AISI 304
Medium: -40 .. +135 °C PT5N-xxT
(UL listed -40...+100°C)

Accuracy performance
Type Total Error * Temperature Range
PT5N-07 / 18 ±1% FS -40 … +20 °C
*) Total Error Includes Non-Linearity, Hysteresis, Repeatability As Well As Offset
±1% FS +10 … +50 °C And Span Drift Due To The Temperature Changes.
PT5N-30 / -50/
±2% FS -10 … +80 °C Note: % FS is Related to Percentage of Full sensor Scale.
±1% FS +10 … +50 °C
PT5N-150D
±2% FS -10 … +90 °C

GPC-EN-2024 CONTROLS COMPONENTS 194


Electronic fan speed controller series FSY/FSM
Electronic speed controllers FSY / FSM control the speed of fan motors depending on pressure.

Features
• Adjustable pressure for cut-off
• High Voltage Triac (800 Volts)
• Integrated protection circuit against voltage peaks
• Compact design
• Easy mounting and adjustment
• Easy retrofit in existing systems
• No additional gasket required (completely molded into plug)
• Multi-position plug with EMC filter cable for flexible installation
• per 2014/30/EU (together with FSF cable)
• Other pressure connection upon request (minimum order
volume 100 pieces) FSY-43S

Selection table
Pressure Factory- Max. Allowable Pressure
Type Part No. Test Pressure PT
range * setting * Pressure PS connection
Fan Speed Controllers with Cut-off Mode
FSY-41S 0715533 4.0...12.5 bar 8.0 bar 27 bar 30 bar
FSY-42S 0715534 9.2...21.2 bar 15.0 bar 32 bar 36 bar 7/16”-20 UNF female
FSY-43S 0715537 12.4…28.4 bar 21.8 bar 45 bar 50 bar
Fan Speed Controllers with Min. Speed Mode
FSM-41S 0715520 4.0...2.5 bar 8.0 bar 27 bar 30 bar
FSM-42S 0715521 9.2...21.2 bar 15.0 bar 32 bar 36 bar 7/16”-20 UNF female
FSM-43S 0715522 12.4…28.4 bar 21.8 bar 45 bar 50 bar
Note: *) Pressure at which fan is switched off (FSY) or at which fan is running with minimum speed (FSM)

Cable assemblies with plug and EMC filter


Type Part No. Temperature Range Cable Length
FSF-N15 804640 Cable length 1.5 m
FSF-N30 804641 Temperature Range: -50…+80°C Cable length 3.0 m
FSF-N60 804642 Cable length 6.0 m
Seal Ring Pack 803780 Copper Gaskets 100 pcs

195 GPC-EN-2024 CONTROLS COMPONENTS


Technical data
Supply Voltage 230 VAC, +15%, -20%, 50/60 Hz FSY-41: 4.0...12.5 bar
Clockwise ~ +1.2 bar
Nominal Current FSY: 0.1 – 4.0 A Counterclockwise ~ –1.2 bar
(See Diagram Below) FSM: 0.5 – 4.0 A
FSY-42: 9.2...21.2 bar
Pressure Change Per Turn of
Starting Current Max. 8 A/5 Sec. Clockwise ~ +2.5 bar
Adjustment Screw
Counterclockwise ~ –2.5 bar
R410A, R134a, R404a, R507,
R407C, R407A, R407F, R1234ze, FSY-43: 12.4 .. 28.4 bar
Medium Compatibility Clockwise ~ +3.3 bar
R452A, R448a, R449a, R450A,
R513A, R22 Counterclockwise ~ –3.3 bar

Protection Class According to IP 65 (with Fitted Connectors FSY-41: 2.5 bar


IEC529 /EN 60529 FSF-xxx) Proportional Range FSY-42: 3.8 bar
FSY-43: 4.6 bar

Housing Material PC and PA


Temperature Ranges Ambient
-20...+55°C
(>40°C See Diagramm) (EMC 2014/30/EU, LVD 2014/35/
Storage & Transportation
-30...+70°C Marking EU, RoHS 2011/65/EU) (FSY)
Medium
-20...+70°C

Max. Current vs Ambient Temperature

4
Current (A)

3
2
1
0
30 35 40 45 50 55
Ambient Temperature (°C)
Note: 3.0A at 55°C

Function diagram
The control behaviour can be easily described by looking at the
function of output voltage versus input pressure: In the maximum
range the FSY provides a constant output voltage of approximately
1% below the supply voltage. The fan is running at maximum
speed.

Along the proportional range, the output voltage varies between


maximum and minimum voltage of approximately 50% of the
supply voltage. This causes the fan to slow down from maximum
to minimum speed.

Further decrease of pressure in the minimum range leads to cut-off


of the fan motor. Reincrease of input pressure will start the motor
with a hysteresis of approximately 0.7 bar to avoid cycling. The
pressure from which motor cuts off is adjustable (see selection
table - adjustment range).
FSY

FSM

GPC-EN-2024 CONTROLS COMPONENTS 196


FSE fan speed control module
Electronic fan speed control modules FSE generate a 0…10 V signal, which is used
to control the speed of condenser fan motors in commercial refrigeration and
air-conditioning systems. Ideal for use with high efficient EC-motors, but can be
also used with phase cut controllers for induction motors.

Features
• Energy saving due to improved cooling efficiency
• Pressure for minimum speed adjustable
• Small proportional band and large hysteresis to minimize cycling
at small pressure changes
• Reduced fan noise level during low ambient temp. conditions
• Improved overall performance of cooling system
• Easy installation with cables for power supply and motor
FSE Control Modules
connection factory wired
• IP 65 protection for outdoor mounting suitable for any size of
EC fan motors
• UL file nr.: E355325 (Released for 43 bar)

Selection table control modules FSE


Adjustment Range Max. Allowable Pressure
Type Part No. Factory settings PT
PCut* Pressure PS Connection
7/16” -20 UNF
FSE-01S 804 701 4 … 12.5 bar 7.8 bar 27 bar 30 bar
female
7/16” -20 UNF
FSE-02S 804 706 10 … 21 bar 15.5 bar 32 bar 36 bar
female
7/16” -20 UNF
FSE-03S 804 711 12 … 28 bar 20.4 bar 45 bar 50 bar
female

Cable assemblies for connection of FSE control module to controller


Diameter
Type Part No. No of Leads Temperature Range Cable Length
of Leads

PS3-N15 804 580 1.5 m

PS3-N30 804 581 3 0.75 mm2 -25...+80°C 3.0 m

PS3-N60 804 582 6.0 m

Technical data FSE


Supply Voltage 10 V; Supplied by Controller Pressure Connection
FSE-01S and FSE-02S Brass
Operating Current FSE-03S Stainless Steel
Max. 1 mA
0…10 VDC Output
Temperature Range
Storage and Transportation -30 … +70°C
R410A, R134a, R404a, R507, R407C, Operation -20 … +65°C
Medium Compatibility R1234ze, R452A, R448A, R449A,
R450A, R513A, R22 Materials
PA
Housing Cover
Protection Class IP 65 with Cable Connector
(IEC529/EN 60529) Assemblies PS3-Nxx Marking UL (File No.E355325)

197 GPC-EN-2024 CONTROLS COMPONENTS


GPC-EN-2024 CONTROLS COMPONENTS 198
199 GPC-EN-2024 CONTROLS COMPONENTS
Thermo™-Expansion Valves

Basic terms and technical information


Operating principles Adsorption charges

Thermo-Expansion valves control the superheat of refrigerant These charges feature control characteristics much like MOP
vapor at the outlet of the evaporator. They act as a throttle charges but avoid the difficulties of cross-ambient interference.
device between the high pressure and the low pressure sides of Response time is slow but perfectly suitable for common refriger­­
refrigeration systems and ensure that the rate of refrigerant flow ation systems. Maximum bulb temperature is 130°C.
into the evaporator exactly matches the rate of evaporation of
liquid refrigerant in the evaporator. Thus the evaporator is fully
utilized and no liquid refrigerant may reach the compressor.
MOP (Maximum Operating Pressure)
MOP functionality is somewhat similar to the application of a
Description of bulb charges crankcase pressure regulator. Evaporator pressures are limited
to a maximum value to protect compressor from overload
The application ranges of Thermo-Expansion valves are heavily conditions. MOP selection should be within maximum allowed
influenced by the charge selected. low pressure rating of the compressor and should be at
approximately 3 K above evaporating temperatures.

Liquid charges Practical hint: superheat adjustments influence the MOP:


Increase of superheat: Decrease of MOP
The behaviour of Thermo-Expansion valves with liquid charges Decrease of superheat: Increase of MOP
is exclusively determined by temperature changes at the bulb
and not subject to any cross-ambient interference. They feature
a fast response time and thus react quickly in the control circuit. Static superheat
Liquid charges cannot incorporate MOP functions. Maximum
bulb temperatures shall not exceed 75°C. Thermo-Expansion valves are factory preset for optimum
superheat settings. This setting should be modified only if abso­
lutely necessary. The readjustment should be at the lowest
Gas charges expected evaporating temperature.

The behaviour of Thermo-Expansion valves with gas charges


will be determined by the lowest temperature at any part of the
expansion valve (power assembly, capillary tube or bulb). If any
parts other than the bulb are subject to the lowest temperature,
malfunction of the expansion valve may occur (i.e., erratic low
pressure or excessive superheat). Thermo-Expansion valves
with gas charges always feature MOP functions and include
ballasted bulbs. Ballast in the bulb leads to slow opening and
fast closure of the valve. Maximum bulb temperature is 120°C.

GPC-EN-2024 CONTROLS COMPONENTS 200


Subcooling Dimensioning
Subcooling generally increases the capacity of the refrigeration To facilitate valve dimensioning for other conditions, please
system and may be accounted for when dimensioning an use Copeland Select software which can be downloaded from
expansion valve by applying the correction factor Kt. The copeland.com/en-gb.
capacity corrections for evaporating temperature, condensing
temperature and subcooling are all incorporated in Kt. These See copeland.com/en-gb for contact addresses, email, phone
are, in particular the liquid density upstream from the expansion numbers or downloads.
valve, the different enthalpies of liquid and vapor phase
refrigerants, as well as certain parts of flash gas after expansion.
The percentage of flash gas differs with various refrigerants and
depends on system conditions.

Heavy subcooling results in very small flash gas amounts


and therefore increases expansion valve capacities. These
conditions are not covered by Kt. Likewise, small flash gas
amounts lead to reduced evaporator capacities and may result
in substantial discrepancies between the capacities of the
Thermo-expansion valve and the evaporator. These effects
have been integrated in Copeland Select software.

201 GPC-EN-2024 CONTROLS COMPONENTS


Dimensioning of Thermo™- expansion
valves for systems with refrigerant
having temperature glide

As opposed to single substances (e.g. R 134a) where the phase


change takes place at a constant temperature/pressure the
evaporation and condensation of zeotropic blends are in a ”gliding”
form (e.g. at a constant pressure the temperature varies within a certain
range) through evaporators and condensers. HFO blends R448A and
R449A are zeotropic blends.

The condensing /evaporating pressure must be determined at


saturated temperatures (bubble for liquid / dew points for vapor)
for dimensioning of the expansion valves, solenoid valves etc. The
corresponding dew point for liquid pressures is provided in case of
compressor selection based on dew point of liquid pressure.

Selection table for expansion valves


Selection Criteria
Series Capacity Range Evaporating Temp. Range
Main Application Features
R448A (kW) (°C)

Refrig./Air Cond.
TI 0.5...19.4 +20...-45 Exchangeable orifices
Heat Pumps

Refrig./Air Cond. Hermetic, superheat adjustable,


TIH 3.1...28.4 +20...-45
Heat Pumps Optional with bleed hole

TX7 32...183 (R410A) +20...-45 Air-Cond. Heat Pumps Hermetic, superheat adjustable

Refrig./Air Cond. Exchangeable orifices,


T 1.9.. 301 +30...-45
Heat Pumps Power-assembly and flange

Low Temperature Exchangeable orifices,


ZZ 1.7...24.7 -45...-120
Application Power-assembly and flange

Liquid Injection Superheat Exchangeable orifices,


L 1.9...222 +30...-50
Control Power-assembly and flange

Liquid Injection Exchangeable orifices,


935 5.2...59.8 +30...-45
Temperature Control Power-assembly and flange

GPC-EN-2024 CONTROLS COMPONENTS 202


Thermo™- expansion valves series TI with interchangeable orifices

Features
• Internal or external equaliser
• Laser-welded diaphragm / power element with large diameter
for high reliability and maximum lifetime • Cleanable / exchangeable inlet strainer in orifice assembly
• Constant superheat across wide application ranges • Inlet brazing adapter
• Easy and precise superheat setting by internal fine threads • Capillary tube length 1.5 m
• Three styles of connections: • Max. allowable pressure PS: 45 bar
- TILE: Stainless steel brazed fittings eliminate the • Temperature range TS: -45...+75°C
need of wet rags during brazing • CE Marking acc. PED not required
- TIS(E): Copper brazed fittings (valve requires wet
rag during brazing
- TI(E): Flare
• With capacities between 0.5kW and 19.4 kW (R448A) ideally
suited for service work

Type code
TI S E – M W

Valve series
Connection type
L: Brazing, stainless steel ODF fittings
(outlet / equaliser)
S : Brazing, copper ODF fittings
: Flare
Equaliser
E : External
: Internal
Refrigerant
Charge TILE
W: Liquid (without MOP feature)
Wxxx: Vapor (with MOP feature)
ADxxx: Adsorption (similar MOP feature) TIE

Selection table for orifice assembly with strainer for inlet connection
Nominal Capacity (kW)
Type TIO-00X TIO-000 TIO-001 TIO-002 TIO-003 TIO-004 TIO-005 TIO-006
Part No. 800 532 800 533 800 534 800 535 800 536 800 537 800 538 800 539
R134a 0.3 0.8 1.9 3.1 5.0 8.3 10.1 11.7
R22 0.5 1.3 3.2 5.3 8.5 13.9 16.9 19.5
R404A/R507 0.4 1.0 2.3 3.9 6.2 10.1 12.3 14.2
R407C 0.5 1.4 3.5 5.7 9.2 15 18.3 21.1
A1

R410A 0.6 1.5 3.7 6.2 9.9 16.2 19.7 22.8


R448A 0.5 1.3 3.2 5.3 8.5 13.9 16.9 19.4
R449A 0.5 1.3 3.1 5.2 8.3 13.5 16.5 19.0
R513A/R450A 0.3 0.7 1.7 2.8 4.5 7.5 9.1 10.6
R452A 0.4 1.0 2.4 4.0 6.4 10.5 12.8 14.8
R1234ze 0.2 0.6 1.5 2.4 3.9 6.5 7.9 9.1
R455A 0.5 1.2 3.0 5.0 8.1 13.2 16.0 18.5
A2L

R454C 0.4 1.1 2.6 4.3 7.0 11.4 13.8 16.0


R1234yf 0.2 0.6 1.4 2.2 3.6 6.0 7.3 8.4
R32 0.9 2.3 5.6 9.2 14.8 24.1 29.3 33.9
Note: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K.
For selection of other operation conditions, please use Copeland Select software.

Brazing adapter for TILE and TIS(E)


Part Connection, ODF
Type No.
(mm) (inch)
TIA-M06 802 500 6.0 -
TIA-M10 802 501 10.0 -
TIA-014 802 502 - 1/4”
TIA-038 802 503 - 3/8”
Gasket Set 803 780 100 pieces

203 GPC-EN-2024 CONTROLS COMPONENTS


TI valve bodies without orifice and nut
Evaporating
Outlet/Equalizer MOP
Refrigerant Type Part No. Type Part No. Temperature
Connection (°C)
Range (°C)

A1 A2L External Equalizer Internal Equalizer

TILE-SW (12 mm) 802465 - -45 ... +20


Brazing Stainless
Steel Fittings *
TILE-SW (1/2”) 802466 - -45 ... +20

TISE-SW (12 mm) 802462 TIS-SW (12 mm) 802461 - -45 ... +20

TISE-SW (1/2”) 802464 TIS-SW (1/2”) 802463 - -45 ... +20

TISE-SAD10 (1/2”) 802479 TIS-SAD10 (1/2”) 802478 +10 -45 ... 0

R404A/R507 Brazing Copper


TISE-SW75 (12 mm) 802471 0 -45 ... -3
Fittings **
TISE-SW75 (1/2”) 802472 0 -45 ... -3
R452A*
TISE-SAD-20 (12 mm) 802474 -20 -45 ... -27

TISE-SAD-20 (1/2”) 802475 -20 -45 ... -27

TIE-SW 802460 TI-SW 802459 - -45 ... +20

TIE-SAD10 802477 +10 -45 ... 0


Flare Fittings
TIE-SW75 802470 TI-SW75 802469 0 -45 ... -3

TIE-SAD-20 802473 -20 -45 ... -27

TILE-MW (12 mm) 802451 - -45 ... +20


Brazing Stainless
Steel Fittings *
TILE-MW (1/2”) 802452 - -45 ... +20

TISE-MW (12 mm) 802448 TIS-MW (12 mm) 802447 - -45 ... +20

R134a TISE-MW (1/2”) 802450 TIS-MW (1/2”) 802449 - -45 ... +20
Brazing Copper
R1234ze*
Fittings **
R450A* TISE-MW55 (12 mm) 802457 +14 -45 ... +11

TISE-MW55 (1/2”) 802458 +14 -45 ... +11

TIE-MW 802446 TI-MW 802445 - -45 ... +20


Flare Fittings
TIE-MW55 802456 TI-MW55 802455 +14 -45 ... +11

TILE-NW (12 mm) 802486 - -45 ... +20


Brazing Stainless
Steel Fittings *
TILE-NW (1/2”) 802485 - -45 ... +20

R407C TISE-NW (12 mm) 802438 TIS-NW (12 mm) 802437 - -45 ... +20
Brazing Copper
Fittings **
TISE-NW (1/2”) 802440 TIS-NW (1/2”) 802439 - -45 ... +20

Flare Fittings TIE-NW 802436 TI-NW 802435 - -45...+20

TILE-ZW (12 mm) 802488 - -35...+20

TILE-ZW (1/2”) 802489 - -35...+20


Brazing Stainless
R410A R32*
Steel Fittings *
TILE-ZW175 (12 mm) 802490 +16.4 -35...+15

TILE-ZW175 (1/2”) 802491 +16.4 -35...+15

TILE-BW (12 mm) 802418 - -45...+20


Brazing Stainless
Steel Fittings *
TILE-BW (1/2”) 802419 - -45...+20

TISE-BW (12 mm) 802416 TIS-BW(12 mm) 802414 - -45...+20


R448A /
TISE-BW (1/2”) 802417 TIS-BW(1/2”) 802415 - -45...+20
R449A Brazing Copper
Fittings **
TISE-BW30 (12 mm) 802494 -15 -45...-18

TISE-BW30 (1/2”) 802495 -15 -45...-18

Flare Fittings TIE-BW 802413 TI-BW 802412 - -45...+20

Note: *) TILE Brazing without wet rag


**) TISE Brazing with wet rag
***) Superheat readjustment required - see Operating Instruction

GPC-EN-2024 CONTROLS COMPONENTS 204


TI valve bodies without orifice and nut
Evaporating
Outlet/Equalizer MOP
Refrigerant Type Part No. Type Part No. Temperature
Connection (°C)
Range (°C)

A1 A2L External Equalizer Internal Equalizer


R513A Brazing Stainless TILE-CW (12 mm) 802166 - -30...+20°C
Steel Fittings**
TILE-CW (1/2") 802167 - -30...+20°C

Brazing Copper TISE-CW (12 mm) 802168 TIS-CW (12 mm) 802170 - -30...+20°C
Fittings***
TISE-CW (1/2") 802169 TIS-CW (1/2") 802171 - -30...+20°C

Flare Fittings TIE-CW 802172 TI-CW 802173 - -30...+20°C

R454C Brazing Stainless TILE-LW (12 mm) 802150 - -35...+20°C


Steel Fittings**
TILE-LW (1/2") 802151 - -35...+20°C

Brazing Copper TISE-LW (12 mm) 802152 TIS-LW (12 mm) 802154 - -35...+20°C
Fittings***
TISE-LW (1/2") 802153 TIS-LW (1/2") 802155 - -35...+20°C

Flare Fittings TIE-LW 802156 TI-LW 802157 - -35...+20°C

R455A Brazing Stainless TILE-KW (12 mm) 802158 - -35...+20°C


Steel Fittings**
TILE-KW (1/2") 802159 - -35...+20°C

Brazing Copper TISE-KW (12 mm) 802160 TIS-KW (12 mm) 802162 - -35...+20°C
Fittings***
TISE-KW (1/2") 802161 TIS-KW (1/2") 802163 - -35...+20°C

Flare Fittings TIE-KW 802164 TI-KW 802165 - -35...+20°C

R1234yf Brazing Stainless TILE-FW (12 mm) 802174 - -35...+20°C


Steel Fittings**
TILE-FW (1/2") 802175 - -35...+20°C

Brazing Copper TISE-FW (12 mm) 802176 TIS-FW (12 mm) 802178 - -35...+20°C
Fittings***
TISE-FW (1/2") 802177 TIS-FW (1/2") 802179 - -35...+20°C

Flare Fittings TIE-FW 802180 TI-FW 802181 - -35...+20°C

Note: *) TILE Brazing without wet rag


**) TISE Brazing with wet rag
***) Superheat readjustment required - see Operating Instruction

Connections
Inlet Connection
Body Outlet External Equalizer*
Brazing with Adapter Flare

TI(E) 5/8”-18 UNF Flare suitable for 3/4” - 16 UNF Flare: 7/16” - 20 UNF Flare:
-
Flare connections 6 mm, 8 mm, 10 mm, /4”, 5/16”, 3/8” tubes for 12 mm, 1/2” tubes for 6 mm, 1/4” tubes
TIA - M06 (6 mm ODF)
12 mm ODF 6 mm ODF
TIS(E) / TILE TIA - M10 (10 mm ODF)
Braze connections TIA - 014 (1/4” ODF)
1/2 ODF 1/4” ODF
TIA - 038 (3/8” ODF)
Note: *) TIE, TISE and TILE

205 GPC-EN-2024 CONTROLS COMPONENTS


Thermo™- Expansion Valves series TIH for OEM use, hermetic design

Features
• Compact size and hermetic design
• Up to 35 kW for R410A, 49 kW for R32
• Brazing and metric connections with straight through configuration
• Stainless steel power element resists corrosion
• Large diaphragm provides smoother and consistent valve control
• Internal or external equalizer TIH
• External superheat adjustment
• Standard with integrated 100 mesh size strainer at inlet of valve
• Packaging with 20 pieces necked including bulb fastening accessories and single
operating instruction

Options
• Single engineering sample for test purpose
• Special setting or bleed hole function on request: minimum order quantity 100
pieces per batch, type and order
• Valve without internal strainer on request: minimum order quantity 100 pieces per
batch, type and order

Selection table R32 / R410A / R452B / R454B


Nominal Capacity (kW) with MOP Connection

R410A R32* R452B* R454B* Type Part No. Inlet Outlet Equalizer

3.6 5.4 4.1 4.2 TIH-Z12m 802622M 6 mm 10 mm internal

3.6 5.4 4.1 4.2 TIH-Z12 802636M 1/4" 3/8" internal

6.0 9.0 6.9 6.9 TIH-Z13m 802623M 6 mm 10 mm internal

6.0 9.0 6.9 6.9 TIH-Z13 802637M 1/4" 3/8" internal

8.4 12.5 9.6 9.7 TIH-Z14m 802624M 10 mm 12 mm internal

8.4 12.5 9.6 9.7 TIH-Z14 802638M 3/8" 1/2" internal

3.6 5.4 4.1 4.2 TIH-Z32m 802625M 6 mm 10 mm 6 mm

3.6 5.4 4.1 4.2 TIH-Z32 802639M 1/4" 3/8" 1/4"

6.0 9.0 6.9 6.9 TIH-Z33m 802626M 6 mm 10 mm 6 mm

6.0 9.0 6.9 6.9 TIH-Z33 802640M 1/4" 3/8" 1/4"

8.4 12.5 9.6 9.7 TIH-Z34m 802627M 10 mm 12 mm 6 mm

8.4 12.5 9.6 9.7 TIH-Z34 802641M 3/8" 1/2" 1/4"

12.4 18.4 14.2 14.2 TIH-Z35m 802628M 10 mm 12 mm 6 mm

12.4 18.4 14.2 14.2 TIH-Z35 802642M 3/8” 1/2" 1/4"

14.6 21.8 16.7 16.8 TIH-Z36m 802629M 10 mm 12 mm 6 mm

14.6 21.8 16.7 16.8 TIH-Z36 802643M 3/8” 1/2" 1/4"

20.8 31.0 23.8 23.9 TIH-Z37m 802630M 12 mm 16 mm 6 mm

20.8 31.0 23.8 23.9 TIH-Z37 802644M 1/2” 5/8" 1/4"

23.2 34.6 26.6 26.7 TIH-Z38m 802631M 12 mm 16 mm 6 mm

23.2 34.6 26.6 26.7 TIH-Z38 802645M 1/2" 5/8" 1/4"

26.7 39.7 30.5 30.7 TIH-Z39m 802632M 12 mm 16 mm 6 mm

26.7 39.7 30.5 30.7 TIH-Z39 802646M 1/2” 5/8" 1/4"

33.2 49.4 38.0 38.2 TIH-Z3Am 802633M 12 mm 16 mm 6 mm

33.2 49.4 38.0 38.2 TIH-Z3A 802647M 1/2" 5/8" 1/4"

Note 1: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: *) Superheat readjustment required - see Operating Instruction

GPC-EN-2024 CONTROLS COMPONENTS 206


Selection table R134a / R450A
Capacity (kW) without MOP with MOP Connection
R134a R450A* Type Part No. Type Part No. Inlet Outlet Equalizer
2.4 2.1 TIH-M02m 802510M TIH-M12m 802538M 6 mm 10 mm internal
2.4 2.1 TIH-M02 802524M TIH-M12 802552M 1/4" 3/8" internal
4.0 3.5 TIH-M03m 802511M TIH-M13m 802539M 6 mm 10 mm internal
4.0 3.5 TIH-M03 802525M TIH-M13 802553M 1/4" 3/8" internal
5.6 4.9 TIH-M04m 802512M TIH-M14m 802540M 10 mm 12 mm internal
5.6 4.9 TIH-M04 802526M TIH-M14 802554M 3/8" 1/2" internal
2.4 2.1 TIH-M22m 802513M TIH-M32m 802541M 6 mm 10 mm 6 mm
2.4 2.1 TIH-M22 802527M TIH-M32 802555M 1/4" 3/8" 1/4"
4.0 3.5 TIH-M23m 802514M TIH-M33m 802542M 6 mm 10 mm 6 mm
4.0 3.5 TIH-M23 802528M TIH-M33 802556M 1/4" 3/8" 1/4"
5.6 4.9 TIH-M24m 802515M TIH-M34m 802543M 10 mm 12 mm 6 mm
5.6 4.9 TIH-M24 802529M TIH-M34 802557M 3/8" 1/2" 1/4"
8.2 7.2 TIH-M25m 802516M TIH-M35m 802544M 10 mm 12 mm 6 mm
8.2 7.2 TIH-M25 802530M TIH-M35 802558M 3/8" 1/2" 1/4"
9.7 8.5 TIH-M26m 802517M TIH-M36m 802545M 10 mm 12 mm 6 mm
9.7 8.5 TIH-M26 802531M TIH-M36 802559M 3/8" 1/2" 1/4"
13.8 12.2 TIH-M27m 802518M TIH-M37m 802546M 12 mm 16 mm 6 mm
13.8 12.2 TIH-M27 802532M TIH-M37 802560M 1/2" 5/8" 1/4"
15.4 13.6 TIH-M28m 802519M TIH-M38m 802547M 12 mm 16 mm 6 mm
15.4 13.6 TIH-M28 802533M TIH-M38 802561M 1/2" 5/8" 1/4"
17.7 15.6 TIH-M39m 802520M TIH-M39m 802548M 12 mm 16 mm 6 mm
17.7 15.6 TIH-M29 802534M TIH-M39 802562M 1/2" 5/8" 1/4"
22.0 19.4 TIH-M3Am 802521M TIH-M3Am 802549M 12 mm 16 mm 6 mm
22.0 19.4 TIH-M2A 802535M TIH-M3A 802563M 1/2" 5/8" 1/4"
Note 1: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: *) Superheat readjustment required - see Operating Instruction

Selection table R407C / R454C


Capacity (kW) without MOP with MOP Connection
R407C R454C* Type Part No. Type Part No. Inlet Outlet Equalizer
3.3 2.5 TIH-N02m 802566M TIH-N12m 802594M 6 mm 10 mm internal
3.3 2.5 TIH-N02 802580M TIH-N12 802608M 1/4" 3/8" internal
5.4 4.2 TIH-N03m 802567M TIH-N13m 802595M 6 mm 10 mm internal
5.4 4.2 TIH-N03 802581M TIH-N13 802609M 1/4" 3/8" internal
7.6 5.9 TIH-N04m 802568M TIH-N14m 802596M 10 mm 12 mm internal
7.6 5.9 TIH-N04 802582M TIH-N14 802610M 3/8" 1/2" internal
3.3 2.5 TIH-N22m 802569M TIH-N32m 802597M 6 mm 10 mm 6 mm
3.3 2.5 TIH-N22 802583M TIH-N32 802611M 1/4" 3/8" 1/4"
5.4 4.2 TIH-N23m 802570M TIH-N33m 802598M 6 mm 10 mm 6 mm
5.4 4.2 TIH-N23 802584M TIH-N33 802612M 1/4" 3/8" 1/4"
7.6 5.9 TIH-N24m 802571M TIH-N34m 802599M 10 mm 12 mm 6 mm
7.6 5.9 TIH-N24 802585M TIH-N34 802613M 3/8" 1/2" 1/4"
11.2 8.7 TIH-N25m 802572M TIH-N35m 802600M 10 mm 12 mm 6 mm
11.2 8.7 TIH-N25 802586M TIH-N35 802614M 3/8" 1/2" 1/4"
13.2 10.3 TIH-N26m 802573M TIH-N36m 802601M 10 mm 12 mm 6 mm
13.2 10.3 TIH-N26 802587M TIH-N36 802615M 3/8" 1/2" 1/4"
18.8 14.6 TIH-N27m 802574M TIH-N37m 802602M 12 mm 16 mm 6 mm
18.8 14.6 TIH-N27 802588M TIH-N37 802616M 1/2" 5/8" 1/4"
21.0 16.3 TIH-N28m 802575M TIH-N38m 802603M 12 mm 16 mm 6 mm
21.0 16.3 TIH-N28 802589M TIH-N38 802617M 1/2" 5/8" 1/4"
24.1 18.7 TIH-N29m 802576M TIH-N39m 802604M 12 mm 16 mm 6 mm
24.1 18.7 TIH-N29 802590M TIH-N39 802618M 1/2" 5/8" 1/4"
30.0 23.3 TIH-N2Am 802577M TIH-N3Am 802605M 12 mm 16 mm 6 mm
30.0 23.3 TIH-N2A 802591M TIH-N3A 802619M 1/2" 5/8" 1/4"
Note 1: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: *) Superheat readjustment required - see Operating Instruction

207 GPC-EN-2024 CONTROLS COMPONENTS


Selection table R448A / R449A / R454A /R455A
Capacity (kW) without MOP Connection
R448A R449A R454A* R455A* Type Part No. Inlet Outlet Equalizer
3.1 3.0 3.0 2.9 TIH-B02m 802706M 6 mm 10 mm internal
3.1 3.0 3.0 2.9 TIH-B02 802720M 1/4" 3/8" internal
5.1 5.0 5.1 4.9 TIH-B03m 802707M 6 mm 10 mm internal
5.1 5.0 5.1 4.9 TIH-B03 802721M 1/4" 3/8" internal
7.2 7.0 7.1 6.8 TIH-B04m 802708M 10 mm 12 mm internal
7.2 7.0 7.1 6.8 TIH-B04 802722M 3/8" 1/2" internal
3.1 3.0 3.0 2.9 TIH-B22m 802709M 6 mm 10 mm 6 mm
3.1 3.0 3.0 2.9 TIH-B22 802723M 1/4" 3/8" 1/4"
5.1 5.0 5.1 4.9 TIH-B23m 802710M 6 mm 10 mm 6 mm
5.1 5.0 5.1 4.9 TIH-B23 802724M 1/4" 3/8" 1/4"
7.2 7.0 7.1 6.8 TIH-B24m 802711M 10 mm 12 mm 6 mm
7.2 7.0 7.1 6.8 TIH-B24 802725M 3/8" 1/2" 1/4"
10.6 10.3 10.4 10.1 TIH-B25m 802712M 10 mm 12 mm 6 mm
10.6 10.3 10.4 10.1 TIH-B25 802726M 3/8” 1/2" 1/4"
12.5 12.2 12.3 11.9 TIH-B26 mm 802713M 10 mm 12 mm 6 mm
12.5 12.2 12.3 11.9 TIH-B26 802727M 3/8” 1/2" 1/4"
17.8 17.4 17.5 16.9 TIH-B27m 802714M 12 mm 16 mm 6 mm
17.8 17.4 17.5 16.9 TIH-B27 802728M 1/2” 5/8" 1/4"
19.9 19.4 19.6 18.9 TIH-B28m 802715M 12 mm 16 mm 6 mm
19.9 19.4 19.6 18.9 TIH-B28 802729M 1/2" 5/8" 1/4"
22.8 22.3 22.5 21.6 TIH-B29m 802716M 12 mm 16 mm 6 mm
22.8 22.3 22.5 21.6 TIH-B29 802730M 1/2” 5/8" 1/4"
28.4 27.7 28.0 27.0 TIH-B2Am 802717M 12 mm 16 mm 6 mm
28.4 27.7 28.0 27.0 TIH-B2A 802731M 1/2" 5/8" 1/4"
Note 1: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: *) Superheat readjustment required - see Operating Instruction

Selection table R513A / R1234yf


Capacity (kW) without MOP with MOP Connection
R513A R1234yf* Type Part No. Type Part No. Inlet Outlet Equalizer
2.2 1.7 TIH-C02m 808400M TIH-C12m 808428M 6 mm 10 mm internal
2.2 1.7 TIH-C02 808414M TIH-C12 808442M 1/4" 3/8" internal
3.6 2.9 TIH-C03m 808401M TIH-C13m 808429M 6 mm 10 mm internal
3.6 2.9 TIH-C03 808415M TIH-C13 808443M 1/4" 3/8" internal
5.0 4.0 TIH-C04m 808402M TIH-C14m 808430M 10 mm 12 mm internal
5.0 4.0 TIH-C04 808416M TIH-C14 808444M 3/8" 1/2" internal
2.2 1.7 TIH-C22m 808403M TIH-C32m 808431M 6 mm 10 mm 6 mm
2.2 1.7 TIH-C22 808417M TIH-C32 808445M 1/4" 3/8" 1/4"
3.6 2.9 TIH-C23m 808404M TIH-C33m 808432M 6 mm 10 mm 6 mm
3.6 2.9 TIH-C23 808418M TIH-C33 808446M 1/4" 3/8" 1/4"
5.0 4.0 TIH-C24m 808405M TIH-C34m 808433M 10 mm 12 mm 6 mm
5.0 4.0 TIH-C24 808419M TIH-C34 808447M 3/8" 1/2" 1/4"
7.4 5.9 TIH-C25m 808406M TIH-C35m 808434M 10 mm 12 mm 6 mm
7.4 5.9 TIH-C25 808420M TIH-C35 808448M 3/8" 1/2" 1/4"
8.8 7.0 TIH-C26m 808407M TIH-C36m 808435M 10 mm 12 mm 6 mm
8.8 7.0 TIH-C26 808421M TIH-C36 808449M 3/8" 1/2" 1/4"
12.5 10.0 TIH-C27m 808408M TIH-C37m 808436M 12 mm 16 mm 6 mm
12.5 10.0 TIH-C27 808422M TIH-C37 808450M 1/2" 5/8" 1/4"
13.9 11.1 TIH-C28m 808409M TIH-C38m 808437M 12 mm 16 mm 6 mm
13.9 11.1 TIH-C28 808423M TIH-C38 808451M 1/2" 5/8" 1/4"
16.0 12.7 TIH-C29m 808410M TIH-C39m 808438M 12 mm 16 mm 6 mm
16.0 12.7 TIH-C29 808424M TIH-C39 808452M 1/2" 5/8" 1/4"
19.9 15.9 TIH-C2Am 808411M TIH-C3Am 808439M 12 mm 16 mm 6 mm
19.9 15.9 TIH-C2A 808425M TIH-C3A 808453M 1/2" 5/8" 1/4"
Note 1: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: *) Superheat readjustment required - see Operating Instruction

GPC-EN-2024 CONTROLS COMPONENTS 208


Standard MOPs

Recommended Max. Design


Refrigerant Standard MOP Corresponding Temperature
Evaporating Temperature

R134a 3.8 bar +16°C +12°C

R513A 3.8 bar +14°C +10°C

R407C 6.9 bar +14.5°C +12.5°C

R410A 13.4 bar +20°C +18°C

R32 13.4 bar +20°C +18°C

R452B 13.4 bar +22°C +20°C

R454B 13.4 bar +22°C +20°C

Charge MOP Refrigerant Maximum Bulb Temperature

TIH-M0../M2.. - R134a +100°C

TIH-N0../N2.. - R407C +80°C

TIH-B0../B2.. - R448A, R449A +80°C

TIH-C0../C2.. - R513A +100°C

TIH-M1../M3.. 3.8 bar R134a +120°C

TIH-C1../C3.. 3.8 bar R513A +120°C

TIH-N1../N3.. 6.9 bar R407C +120°C

TIH-Z1../Z3.. 12.1 bar R410A +120°C

209 GPC-EN-2024 CONTROLS COMPONENTS


Thermo™-expansion valves series TX7
TX7 series of Thermo-expansion valves are designed predominantly for
air conditioning, heat pumps, close control and industrial process cooling
applications. The TX7 is ideal for those applications requiring hermetic /
compact size combined with stable and accurate control over wide load
and evaporating temperature ranges.

Features
• Monoblock, hermetic valve with brazing connections
• 7 sizes up to 180 kW (R410A)
• Maximum allowable pressure: PS 46 bar
• Factory test pressure PT: 50.6 bar
• Bi-Flow application
- Balanced port in normal and reverse flow directions eliminates
disturbance forces resulting from condensing pressure
- Optimum static superheat in normal and reverse flow
-C apacities performance in normal and reverse flow correlates to
capacity of heat pumps in cooling and heating mode
TX7-Z13
• Power element with 65 mm diameter enables low partial load
(20-25%) performance at stable superheat
• Applicable in systems with digital scroll, step less screw compressors
and variable speed compressors
• Floating superheat in reverse flow (heating mode) supports evaporator
efficiency during low ambient operating conditions in air cooled
reversible chillers
• Laser welded stainless steel power element with a special diaphragm
profile provides life expectancy against high pressure during reversed
flow via external equalizer.
• Single diaphragm with negligible hysteresis withstands against
higher pressure
• Fine tuning by external superheat adjusting mechanism
• Special factory setting upon request. Minimum order quantity 60 pieces

Selection table R410A / R32 / R452B / R454B


Nominal Capacity (kW)
With MOP Connection
R410A R32* R452B* R454B*
Normal Reverse Normal Reverse Normal Reverse Normal Reverse
Type Part No. Inlet x Outlet Equalizer
Flow Flow Flow Flow Flow Flow Flow Flow
32.1 31.7 47.7 46.9 36.7 36.3 36.9 36.5 TX7-Z13m 806811 12 mm x 16 mm 6 mm
32.1 31.7 47.7 46.9 36.7 36.3 36.9 36.5 TX7-Z13 806810 1/2” x 5/8” 1/4”
39.9 39.1 59.3 57.8 45.6 44.7 45.8 44.9 TX7-Z14m 806813 16 mm x 22 mm 6 mm
39.9 39.1 59.3 57.8 45.6 44.7 45.8 44.9 TX7-Z14 806812 5/8” x 7/8” 1/4”
48.9 47.4 72.7 70.1 55.9 54.2 56.1 54.4 TX7-Z15m 806815 16 mm x 22 mm 6 mm
48.9 47.4 72.7 70.1 55.9 54.2 56.1 54.4 TX7-Z15 806814 5/8” x 7/8” 1/4”
80.7 67.7 120 100.2 92.2 77.4 92.7 77.9 TX7-Z16m 806817 22 mm x 28 mm 6 mm
80.7 67.7 120 100.2 92.2 77.4 92.7 77.9 TX7-Z16 806816 7/8” x 1-1/8” 1/4”
99.4 81.5 147.9 120.5 113.7 93.2 114.3 93.7 TX7-Z17m 806819 22 mm x 28 mm 6 mm
99.4 81.5 147.9 120.5 113.7 93.2 114.3 93.7 TX7-Z17 806818 7/8” x 1-1/8” 1/4”
130.9 113.9 194.7 168.4 149.7 130.2 150.4 130.8 TX7-Z18m 806821 22 mm x 28 mm 6 mm
130.9 113.9 194.7 168.4 149.7 130.2 150.4 130.8 TX7-Z18 806820 7/8” x 1-1/8” 1/4”
183.4 165.1 272.9 244.1 209.8 188.8 210.8 189.7 TX7-Z19m 806823 22 mm x 28 mm 6 mm
183.4 165.1 272.9 244.1 209.8 188.8 210.8 189.7 TX7-Z19 806822 7/8” x 1-1/8” 1/4”
Note 1: *) Superheat readjustment required - see Operating Instruction
Note 2: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K

GPC-EN-2024 CONTROLS COMPONENTS 210


Selection table R134a / R450A / R513A / R1234yf

Nominal Capacity (kW) with without


Connection
R134a Reverse R450A* R513A* R1234yf* MOP MOP

Reverse

Reverse

Reverse
Normal

Normal

Normal

Normal
Flow

Flow

Flow

Flow

Flow

Flow

Flow

Flow
Type Part No. Type Part No. Inlet x Outlet Equalizer

18.1 17.9 15.9 15.8 16.3 16.1 13.0 12.9 TX7-M13m 806839 TX7-M03m 806825 12 mm x 16 mm 6 mm
18.1 17.9 15.9 15.8 16.3 16.1 13.0 12.9 TX7-M13 806838 TX7-M03 806824 1/2” x 5/8” 1/4”
22.5 22.0 19.8 19.4 20.3 19.9 16.2 15.9 TX7-M14m 806841 TX7-M04m 806827 16 mm x 22 mm 6 mm
22.5 22.0 19.8 19.4 20.3 19.9 16.2 15.9 TX7-M14 806840 TX7-M04 806826 5/8” x 7/8” 1/4”
27.5 26.7 24.3 23.5 24.8 24.1 19.8 19.2 TX7-M15m 806843 TX7-M05m 806829 16 mm x 22 mm 6 mm
27.5 26.7 24.3 23.5 24.8 24.1 19.8 19.2 TX7-M15 806842 TX7-M05 806828 5/8” x 7/8” 1/4”
45.4 38.2 40.1 33.6 41.0 34.4 32.8 27.5 TX7-M16m 806845 TX7-M06m 806831 22 mm x 28 mm 6 mm
45.4 38.2 40.1 33.6 41.0 34.4 32.8 27.5 TX7-M16 806844 TX7-M06 806830 7/8” x 1-1/8” 1/4”
56.0 45.9 49.4 40.5 50.6 41.5 40.4 33.1 TX7-M17m 806847 TX7-M07m 806833 22 mm x 28 mm 6 mm
56.0 45.9 49.4 40.5 50.6 41.5 40.4 33.1 TX7-M17 806846 TX7-M07 806832 7/8” x 1-1/8” 1/4”
73.7 64.1 65.0 56.6 66.6 57.9 53.2 46.3 TX7-M18m 806849 TX7-M08m 806835 22 mm x 28 mm 6 mm
73.7 64.1 65.0 56.6 66.6 57.9 53.2 46.3 TX7-M18 806848 TX7-M08 806834 7/8” x 1-1/8” 1/4”
103.3 93.0 91.1 82.0 93.3 83.9 74.5 67.0 TX7-M19m 806851 TX7-M09m 806837 22 mm x 28 mm 6 mm
103.3 93.0 91.1 82.0 93.3 83.9 74.5 67.0 TX7-M19 806850 TX7-M09 806836 7/8” x 1-1/8” 1/4”

Selection table R407C / R454C


Nominal Capacity (kW)
with MOP without MOP Connection
R407C R454C*

Normal Reverse Normal Reverse


Type Part No. Type Part No. Inlet x Outlet Equalizer
Flow Flow Flow Flow

28.9 28.6 22.5 22.3 TX7-N13m 806868 TX7-N03m 806853 12 mm x 16 mm 6 mm


28.9 28.6 22.5 22.3 TX7-N13 806867 TX7-N03 806852 1/2” x 5/8” 1/4”
36.0 35.2 27.9 27.4 TX7-N14m 806870 TX7-N04m 806855 16 mm x 22 mm 6 mm
36.0 35.2 27.9 27.4 TX7-N14 806869 TX7-N04 806854 5/8” x 7/8” 1/4”
44.1 42.7 34.2 33.2 TX7-N15m 806872 TX7-N05m 806857 16 mm x 22 mm 6 mm
44.1 42.7 34.2 33.2 TX7-N15 806871 TX7-N05 806856 5/8” x 7/8” 1/4”
72.7 61.1 56.5 47.5 TX7-N16m 806874 TX7-N06m 806859 22 mm x 28 mm 6 mm
72.7 61.1 56.5 47.5 TX7-N16 806873 TX7-N06 806858 7/8” x 1-1/8” 1/4”
89.7 73.5 69.7 57.1 TX7-N17m 806876 TX7-N07m 806861 22 mm x 28 mm 6 mm
89.7 73.5 69.7 57.1 TX7-N17 806875 TX7-N07 806860 7/8” x 1-1/8” 1/4”
118.1 102.7 91.8 79.8 TX7-N18m 806878 TX7-N08m 806863 22 mm x 28 mm 6 mm
118.1 102.7 91.8 79.8 TX7-N18 806877 TX7-N08 806862 7/8” x 1-1/8” 1/4”
165.4 148.9 128.6 115.7 TX7-N19m 806880 TX7-N09m 806865 22 mm x 28 mm 6 mm
165.4 148.9 128.6 115.7 TX7-N19 806879 TX7-N09 806864 7/8” x 1-1/8” 1/4”
Note 1: *) Superheat readjustment required - see Operating Instruction
Note 2: Nominal conditions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K

Recommended Evaporating Maximum Bulb


Charge Refrigerant
Temperature Range Temperature

R134a, R450A,
M0 -25…+30°C 88°C
R513A, R1234yf
N0 R407C, R454C -25…+20°C 71°C
M1 MOP R134a, R450A,
-25…+10°C 120°C
3.8 bar R513A, R1234yf
N1 MOP
R407C, R454C -25…+14°C 120°C
6.9 bar
Z1 MOP R410A/ R32,
-25…+14°C 120°C
12.1 bar R452B, R454B

211 GPC-EN-2024 CONTROLS COMPONENTS


Thermo™-expansion valve series T with
exchangeable power assemblies and orifices

Features
• Modular design for economical logistics and easy
assembly and servicing
• Very good stability due to large diaphragm diameter
• Constant superheat across a wide application range
• Superior partial load performance due to double seat orifice TCLE
design (TJRE, TERE, TIRE & THRE)
• Bi-flow capability for applications in heat pumps
• Capillary tube length 1.5 m (TCLE, TJRE) and 3m
(TERE, TIRE & THRE)
• Max. allowable pressure PS:
- 46 bar with XB power assembly
- 31 bar with XC power assembly
• Medium Temperature range TS: -45…+75°C
• Flanges: brazing ODF/ODM connection

Type code valve Type code power element


TCLE-25 M W 55 WL 10x16 XC 726 - M W 55 2 B

Valve Series Power element


Capacity Code Refrigerant:
Refrigerant: M: R134a N: R407C
S: R404A/R507 Z: R410A
M: R134a N: R407C
B: R448A/R449A C: R513A
S: R404A/R507 Z: R410A
B: R448A/R449A C: R513A Charge Code
Charge Code MOP Code
MOP Code Capillary tube code
Flange Style 1: 1.5 m

WL = Angle Style 2: 3 m

DL = Straight through External equalizer


Connection: Inlet x Outlet

GPC-EN-2024 CONTROLS COMPONENTS 212


Nominal capacities for orifices
Nominal Capacity (kW) Nominal Capacity (kW) Power
Series
Valve

Orifice
Type Type R404A / Element
R134a R513A* R450A* R1234yf* R1234ze* R452A* Type
R507 Type

25MW 1.5 1.3 1.3 1.1 1.1 25SW 1.3 1.4 X22440-B1B

75MW 2.9 2.6 2.5 2.1 2.2 75SW 2.6 2.8 X22440-B2B

150MW 6.1 5.5 5.4 4.4 4.8 150SW 5.6 6.0 X22440-B3B
X22440-
200MW 9.3 8.3 8.1 6.6 7.2 200SW 8.4 9.0
B3,5B
TCLE-

XB1019 ...1B
250MW 13.5 12.1 11.8 9.6 10.5 250SW 12.2 13.1 X22440-B4B

350MW 17.3 15.5 15.1 12.4 13.4 400SW 15.7 16.8 X22440-B5B

550MW 23.6 21.2 20.7 17.0 18.4 600SW 21.5 23.0 X22440-B6B

750MW 32.0 28.7 28.0 22.9 24.8 850SW 29.0 31.1 X22440-B7B

900MW 37.2 33.4 32.6 26.7 28.9 1000SW 33.8 36.2 X22440-B8B

11MW 45.0 40.5 39.6 32.3 35.1 12SW 40.0 43.9 X11873-B4B
TJRE-

13MW 57.0 51.7 50.5 41.3 44.7 14SW 51.0 56.0 X11873-B5B

16MW 71.0 63.5 62.1 50.7 55.0 18SW 63.0 68.9 X9117-B6B

19MW 81.0 72.6 70.9 58.0 62.9 20SW 72.0 78.7 X9117-B7B
TERE-

25MW 112.0 99.8 97.5 79.7 86.4 27SW 99.0 108.3 X9117-B8B

XC726...2B
31MW 135.0 121.5 118.7 97.0 105.2 34SW 120.0 131.7 X9117-B9B
TIRE-

45MW 174.0 155.7 152.1 124.3 134.8 47SW 154.0 168.8 X9166-B10B

55MW 197.0 176.6 172.5 141.1 152.9 61SW 174.0 191.5 X9144-B11B
THRE-

68MW 236.0 210.8 205.9 168.4 182.5 77SW 209.0 228.6 X9144-B13B

Nominal Capacity (kW) Nominal Capacity (kW) Nominal Capacity (kW) Power
Series
Valve

Orifice
Type Type Type Element
R448A R449A R454A* R407C R454C R410A R32 Type
Type

55BW 1.9 1.9 1.8 50NW 2.1 1.6 50ZW 2.2 3.3 X22440-B1B

100BW 3.7 3.6 3.5 100NW 4.0 3.0 100ZW 4.3 6.4 X22440-B2B

250BW 7.9 7.8 7.5 200NW 8.5 6.5 250ZW 9.2 13.7 X22440-B3B

350BW 11.9 11.7 11.3 300NW 12.9 9.7 400ZW 13.9 20.7 X22440-B3,5B
TCLE-

500BW 17.3 17.0 16.4 400NW 18.7 14.2 600ZW 20.2 30.0 X22440-B4B XB1019 ...1B

650BW 22.1 21.8 21.0 550NW 24.0 18.2 750ZW 25.9 38.5 X22440-B5B

850BW 30.3 29.9 28.8 750NW 32.9 24.9 1000ZW 35.5 52.8 X22440-B6B

1150BW 41.0 40.4 38.9 1000NW 44.4 33.6 1400ZW 48 71.4 X22440-B7B

1350BW 47.7 47.0 45.3 1150NW 51.7 39.1 1600ZW 55.8 83.0 X22440-B8B

17BW 57.8 57.0 54.9 14NW 62.0 47.4 19ZW 67.7 100.7 X11873-B4B
TJRE-

21BW 73.8 72.8 70.1 17NW 80.0 60.5 25ZW 86.4 128.5 X11873-B5B

26BW 90.7 89.5 86.2 21NW 99.0 74.4 - - - X9117-B6B

30BW 103.7 102.3 98.5 25NW 112.0 85.1 - - - X9117-B7B


TERE-

41BW 142.6 140.6 135.4 33NW 155.0 117.0 - - - X9117-B8B


XC726...2B

50BW 173.5 171.1 164.8 42NW 188.0 142.3 - - - X9117-B9B


TIRE-

64BW 222.4 219.3 211.2 52NW 241.0 182.4 - - - X9166-B10B

72BW 252.3 248.8 239.6 71NW 273.0 207.0 - - - X9144-B11B


THRE-

86BW 301.1 297.0 286.0 94NW 327.0 247.0 - - - X9144-B13B


Note 1: Nominal condtions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: *) Superheat readjustment required - see Operating Instruction
Note 3: For selection of other operation conditions, please use the “Select” tool.

213 GPC-EN-2024 CONTROLS COMPONENTS


Selection table power element and recommended flanges

Connection (inlet x Outlet) Power


Valve Angle Style Straight Through
Orifice Type Element
Series Type Type
Metric Imperial Type

C501-5 9761-3 - 3/8” x 5/8” ODF


X22440-B1B / B2B/ B3B /
B3.5B / B4B

C501-5mm 9761-3mm 10 x 16 mm ODF -

C501-7 9761-4 1/2” x 5/8” ODF


TCLE

X22440-B5B / B6B

XB1019…2B
C501-7mm 9761-4mm 12 x 16 mm ODF -

- 6346-17 16 x 22 mm ODF 5/8” x 7/8” ODF

X22440-B7B / B8B 5/8” x 7/8” ODF


A576 - -
7/8” x 1-1/8” ODM
16 x 22 mm ODF
A576-mm - -
22 x 28 mm ODM
TJRE

7/8” x 7/8” ODF


X11873-B4B / B5B 10331 10332 22 x 22 mm ODF
1-1/8” x 1-1/8” ODM
TERE

X9117-B6B / B7B / B8B /


B9B
9153 9152 22 x 22 mm ODF 7/8” x 7/8” ODF
9153-mm 9152-mm 22 x 28 mm ODM 1-1/8” x 1-1/8” ODM

XC726…2B
TIRE

X9166 - B10B
THRE

7/8” x 7/8” ODF


X9144-B11B / B13B 9149 9148 22 x 22 mm ODF
1-1/8” x 1-1/8” ODM

MOP charges T-series


MOP Evaporating Temperature Range
R134a R404A/ R507 R407C R410A R448A/ R449A
Code bar
MW SW NW ZW BW
15 1.0 -45... -16°C
30 2.1 -45…-18°C
35 2.4 -45...0°C
40 2.8 -45...-18°C
55 3.8 -45...+11°C -45...-10°C
75 5.2 -45...-2°C
80 5.5 -45...0°C
100 6.9 -45...+14°C
175 12.1 -45...+16°C

Accessories and spare parts


Description Type Part No.

Service Tool for T, ZZ, L and 935 Series valves X 99999 800005
Gasket sets for T, ZZ, L and 935 Series valves X 13455-1 027579
Steel Screws for flange types:
Screw ST 32 803573
C501, 9761, 6346, A576
Steel Screws for flange types:
Screw ST 48 803574
9148, 9149, 9152, 9153, 10331, 10332
Bulb clamp for XB1019 XA 1728-4 803260

Bulb clamp for XC726 XA 1728-5 803261

GPC-EN-2024 CONTROLS COMPONENTS 214


Thermo™- expansion valve series ZZ for low
evaporating temperatures between -45 and -100°C

Features
• Modular design for economical logistics and easy
assembly and servicing ZZCE
• Very good stability due to large diaphragm diameter
• High-quality materials and processes for high reliability
and long lifetime
• To withstand stress at extremely low temperatures,
ZZ-Series valves feature bronze bolts.
• Max. allowable pressure PS:
- 31 bar with XC power assembly

Type code valve Type code power element


ZZC E- 1 1/2 S W 35 WL 10x16 XC 726 - S W 35 2 B

Valve Series Power Assembly


Capacity Code Refrigerant
Refrigerant S: R404A/R507
B (W): R448A/R449A
S: R404A/R507 B (G): R23
B (W): R448A/R449A
B (G): R23 Charge Code
Charge Code MOP Code
MOP Code Capillary tube code
Flange Style 2:3 m

WL=Angle Style External Equalization


DL=Straight through

Connection: Inlet x Outlet

Selection table
Nominal
Nominal Capacity
Capacity Nominal Capacity (kW)
Valve (kW)
Type (kW) Type Type Orifice Power Assembly
Series
R404A / R448A /
R23 R452A R454A R455A
R507 R449A
2BG 1.9 2/4SW 1.2 1.3 1BW 1.7 1.7 1.6 X10-B01
6BG 4.0 1-1/2SW 2.6 2.8 2BW 3.7 3.7 3.4 X10-B02
8BG 6.8 2-1/2SW 4.4 4.6 3BW 6.2 6.2 5.7 X10-B03
ZZCE 12BG 10.8 3-1/2SW 7.0 7.4 5BW 9.8 9.8 9.1 X10-B04 XC726…2B
17BG 16.3 5SW 10.6 11.1 6BW 14.8 14.8 13.7 X10-B05
25BG 21.7 8SW 14.1 14.8 10BW 19.8 19.8 18.2 X10-B06
31BG 27.1 9SW 17.6 18.5 12BW 24.7 24.7 22.8 X10-B07
Note 1: Nominal condtions:
R23: Evaporating Temperature -60°C, Condensing Temperature -25°C, Subcooling 1 K
Other refrigerants: Evaporating Temperature -40°C (dew point), Condensing Temperature 25°C (bubble point), Subcooling 1 K “
Note 2: Attention - To withstand stress at extremely low temperatures, ZZ-Series valves feature bronze bolts. Please order separately Screw BZ 32 Part No. 803575

215 GPC-EN-2024 CONTROLS COMPONENTS


Selection table power element and recommended flanges
Connection Standard
Connection (inlet x outlet) Power
Valve Orifice Flange, Angle Style
Element
Series type
Type Type Metric Imperial Type

C501-5mm 10 X 16 mm ODF
X 10-B01/ B02/ B03
C501-5 3/8” X 5/8 ODF
C501-7 mm 12x16 mm ODF
ZZCE X 10-B04/ B05 XC726 … 2B
C501-7 1/2” x 5/8” ODF -
A 576 mm 16x22 mm ODF
X 10-B04/ B05
A 576 22x28 mm ODM 5/8” x 7/8” ODF

MOP charges ZZ-Series

MOP MOP Evaporating Temperature Range


Code
bar Tmax R23 R404A/R507/R452A R448A/ R449A/R545A/R455A
20 1.4 -66°C -100 … -71°C
35 2.1 -14°C -75 … -18°C
40 2.8 -14°C -75 … -18°C
55 3.8 -7°C -75 … -10°C
60 4.1 -48°C -100 … -51°C
125 8.6 -32°C -100 … -35°C

Accessories and spare parts


Description Type Part No.
Service tool for T, ZZ, L and 935 series valves X 99999 800005
Gasket sets for T, ZZ, L and 935 series valves X 13455-1 027579

Bronze screw for flange types:


Screw BZ 32 803575
C500, C501, 9761, X6346, X6669, A576

Bulb clamp for XC726 XA 1728-5 803261

GPC-EN-2024 CONTROLS COMPONENTS 216


Thermo™-expansion valves L-series with
exchangeable power assemblies and orifices

Features
• Applications for series L valves include superheat control
(desuperheating of suction gas i.e., in hotgas bypass systems
and interstage cooling in multiple stage compressors)
• Modular design for economical logistics and easy LCLE
assembly and servicing
• Very good stability is attained because of the large forces
generated by the large diaphragm diameter
• High-quality materials and processes for high reliability
and long lifetime
• Superior partial load performance due to seat orifice
design (LJRE, LERE & LIRE)
• Max. allowable pressure PS
- 46 bar with XB power assembly
- 31 bar with XC power assembly.
• Medium temperature range TS: -45…+65°C

Type code valve Type code power assembly


LCL E 4 CL WL 10x16 XB1019 CL - 2 B

Valve Series Power element


External Equalizer Charge Code
Capacity Code Capillary tube code
Charge Code 1: 1.5 m
Flange Style 2: 3 m
Connection External equalizer

Nominal capacities for cages


Nominal Capacity Qn
Capacity Code*

(kW)
Power
Valve Orifice
Assembly
R1234yf

R1234ze
R404A /

R513A
R407C

R454C
R450A

R448A

R449A

R410A

R454A

Series Type
R134a

R455A
R507

R32

Type

1* 1.5 1.3 2.1 1.3 1.3 1.9 1.9 2.2 3.3 1.9 1.6 1.1 1.1 1.8 X 22440-B1B
2* 2.9 2.6 4.0 2.5 2.6 3.7 3.6 4.3 6.4 3.6 3.0 2.1 2.2 3.5 X 22440-B2B
3* 6.1 5.6 8.5 5.4 5.5 7.9 7.7 9.2 13.7 7.8 6.5 4.4 4.8 7.5 X 22440-B3B
3.5 * 9.3 8.4 12.9 8.1 8.3 11.9 11.6 13.9 20.7 11.7 9.7 6.6 7.2 11.3 X 22440-B3.5B
LCLE 4* 13.5 12.2 18.7 11.8 12.1 17.3 16.9 20.2 30.0 17.0 14.2 9.6 10.5 16.4 X 22440-B4B
6* 17.3 15.7 24.0 15.1 15.5 22.1 21.6 25.9 38.5 21.8 18.2 12.4 13.4 21.0 X 22440-B5B XB1019 ...2B
7* 23.6 21.5 32.9 20.7 21.2 30.3 29.6 35.5 52.8 29.9 24.9 17.0 18.4 28.8 X 22440-B6B
9* 32.0 29.0 44.4 28.0 28.7 41.0 40.0 48.0 71.4 40.4 33.6 22.9 24.8 38.9 X 22440-B7B
10 * 37.2 33.8 51.7 32.6 33.4 47.7 46.6 55.8 83.0 47.0 39.1 26.7 28.9 45.3 X 22440-B8B
11 * 45.0 40.0 62.0 40.0 40.0 57.8 56.5 67.7 100.7 57.0 47.4 32.3 35.1 54.9 X 11873-B4B
LJRE
12 * 57.0 51.0 80.0 50.0 52.0 73.8 72.1 86.4 128.5 72.8 60.5 41.3 44.7 70.1 X 11873-B5B
13 * 71.0 63.0 99.0 62.0 64.0 90.7 88.6 - - 89.5 74.4 50.7 55.0 86.2 X 9117-B6B
14 * 81.0 72.0 112.0 71.0 73.0 103.7 101.3 - - 102.3 85.1 58.0 62.9 98.5 X 9117-B7B
LERE
15 * 112.0 99.0 155.0 98.0 100.0 142.6 139.3 - - 140.6 117.0 79.7 86.4 135.4 X 9117-B8B XC726…2B
16 * 135.0 120.0 188.0 119.0 121.0 173.5 169.5 - - 171.1 142.3 97.0 105.2 164.8 X 9117-B9B
LIRE- 17 * 174.0 154.0 241.0 152.0 156.0 222.4 217.2 - - 219.3 182.4 124.3 134.8 211.2 X 9166-B10B
Note 1: Nominal condtions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
Note 2: For selection of other operating conditions, please use “Select” software.
Note 3: *) Please indicate designation character for desired superheat.

217 GPC-EN-2024 CONTROLS COMPONENTS


Selection table power assembly and recommended flanges

Connection Standard
Connection (Inlet x Outlet) Power
Valve Orifice Flange, Angle Style
Element
Series Type
Type
Type Type Metric Imperial

C501-5 - 3/8” x 5/8” ODF


X22440-B1B / B2B/
B3B / B3.5B / B4B
C501-5mm 10x16 mm ODF

XB1019…2B
C501-7 1/2” x 5/8” ODF
LCLE
C501-7mm 12x16 mm ODF
X22440-B5B / B6B
5/8” x 7/8” ODF
A576
7/8” x 1 1/8” ODF
16x22 mm ODF
A576-mm -
22x28 mm ODM
7/8” x 7/8” ODF
LJRE X11873-B4B / B5B 10331 10331 22x22 mm ODF
1 1/8” x 1 1/8” ODM

XC726…2B
7/8” x 7/8” ODF
X9117-B6B / B7B / 9153 -
1 1/8” x 1 1/8” ODM
LERE/ LIRE B8B
/ B9B / B10B 22x22 mm ODF
9153-mm
22x28 mm ODM

Suction gas superheat selection:


Refrigerant
* Charge Code R404A / R448A /
R134a R407C R410A R450A R513A R454A R454C R1234yf R1234ze R32 R455A
R507 R449A
CL - 22K 13K 30K 17K - - 19K 13K - - 31K 15K
GL 14K - 25K - 30K 10K 17K 32K 27K 16K - - 28K
UL 30K - - - - 26K - - - - 22K - -
Note: *) Please Indicate Designation Character for Desired Superheat.

Accessories and spare parts


Description Type Part No.

Service Tool for T, ZZ, L and 935 Series valves X 99999 027 579

Gasket sets for T, ZZ, L and 935 Series valves X 13455 -1 800 005

Gasket sets for T, ZZ, L and 935 Series valves


Steel Screws for flange types: Screw ST 32 803 573
C500, C501, 9761, X6346, X6669, A576

Steel Screws for flange types:


Screw ST 48 803 574
9148, 9149, 9152, 9153, 10331, 10332

Bulb clamp for XB1019 XA 1728-4 803260

Bulb clamp for XC726 XA 1728-5 803261

GPC-EN-2024 CONTROLS COMPONENTS 218


Liquid injection valves series 935 with
exchangeable power assemblies and orifices

Features
• Modular design for economical logistics and easy
assembly and servicing
• Very good stability is attained because of the large forces
generated by the large diaphragm diameter
• High-quality materials and processes for high reliability 935
and long lifetime
• Combinations of different charges with various orifice
springs cover a very large application range
• Max. allowabe pressure PS:
- 46 bar with XB power assembly
• Medium Temperature Range TS: -45…+65°C

Type code valve Type code power assembly


935 6 B WL 10x16 XB1019 CL - 2 A

Valve Series Power element


Temperature Code Charge Code
Capacity Code Capillary tube code
Flange style Code 1: 1.5 m
WL: Angle
DL: Straight through 2: 3 m

Connection: Inlet x Outlet Non Equalizer

Nominal capacities for cages


Nominal Capacity Qn
(kW)
Power
Valve Capacity Orifice
R1234yf

Element
R1234ze
R404A/

R448A/
R407C

R454C
R410A

R449A

R450A

R454A

R455A

R513A
R134a

R452a

Series code* Type


R507
R32

Type

A 4.0 9.0 3.8 5.6 6.1 5.2 3.5 5.1 4.3 4.9 3.6 3.9 2.9 3.1 X10-**01
B 7.8 17.5 7.4 10.9 11.8 10.1 6.9 9.9 8.3 9.6 7.1 7.6 5.6 6.1 X10-**02
C 11.1 24.7 10.3 15.4 16.6 14.2 9.7 14.0 11.6 13.4 9.9 10.8 7.9 8.6 X10-**03
XB1019 -
935- * - D 16.3 36.6 15.6 22.8 24.6 21.0 14.4 20.7 17.3 20 14.7 16.0 11.8 12.8 X10-**04
*** - 2A
E 22.5 50.2 21.0 31.2 33.7 28.8 19.7 28.4 23.6 27.4 20.2 21.9 16.1 17.5 X10-**05
G 32.0 71.5 29.9 44.5 48.1 41.1 28.1 40.5 33.7 39.0 28.8 31.2 23.0 24.9 X10-**06
X 46.6 104.2 43.5 64.9 70.0 59.8 40.9 59.0 49.1 56.8 41.9 45.4 33.5 36.3 X10-**07

***)
**) Spring
* ) Temperature Code Temperature Range Charge
code
code
3 -1 ... +17°C B UL
6 +14 ... +38°C C KL
105 +44 ... +70°C C YL
106 +66 ... +94°C C JL
100 +94 ... +121°C C LL

Note: Nominal condtions: Evaporating Temperature +4°C (dew point), Condensing Temperature +38°C (bubble point), Subcooling 1 K
For selection of other operating conditions, please use “Select” program.

219 GPC-EN-2024 CONTROLS COMPONENTS


Selection table power assembly and recommended flanges

Connection Standard
Connection (inlet x outlet) Power
Valve Orifice Flange, Angle Style
Element
Series Type
Type
Type Type Metric Imperial

C501-5 mm 10 x 16 mm ODF
X 10-*01/ *02/ *03
C501-5 3/8” x 5/8 ODF
C501-7 mm 12 x 16 mm ODF
X 10-*04/ *05
935 C501-7 1/2” x 5/8” ODF - XB1019-***-2A
16 x 22 mm ODF
A 576 mm
22 x 28 mm ODM
X 10-*06/ *07
5/8” x 7/8” ODF
A 576
7/8” x 1-1/8” ODM

Accessories and spare parts


Description Type Part No.

Service tool for T, ZZ, L and 935 series valves X 99999 800005

Gasket sets for T, ZZ, L and 935 Series valves X 13455-1 027579

Steel screws for flange types:


Screw ST 32 803573
C500, C501, 9761, X6346, X6669, A576

Bulb clamp for XB1019 XA 1728-4 803260

GPC-EN-2024 CONTROLS COMPONENTS 220


Overview flange for take apart valves

Angle Style Flange Straight Through Flange


(WL) (DL)

Flanges: T- / L-Series
Angle Style Straight Through Connection (Inlet x Outlet)
Valve Series Orifice Type
Type Part No. Type Part No. Metric Imperial

X22440-B1B / B2B/ B3B / C501-5 803232 9761-3 803240 - 3/8”x5/8” ODF


B3.5B / B4B C501-5mm 803233 9761-3mm 803241 10x16 mm ODF
C501-7 803234 9761-4 803350 1/2”x5/8” ODF
X22440-B5B / B6B
C501-7mm 803235 9761-4mm 803243 12x16 mm ODF -
TCLE / LCLE - - 6346-17 803330 16x22 mm ODF 5/8”x7/8” ODF
5/8”x7/8” ODF
A576 803238 - - -
X22440-B7B / B8B 7/8”x1-1/8” ODM
16x22 mm ODF
A576-mm 803239 - - -
22x28 mm ODM
7/8”x7/8” ODF
TJRE / LJRE X11873-B4B / B5B 10331 803338 10332 803324 22x22 mm ODF
1-1/8”x1-1/8” ODM
7/8”x7/8” ODF
9153 803244 9152 803286 -
TERE/ TIRE X9117-B6B / B7B / B8B / B9B 1-1/8”x1-1/8” ODM
LERE/ LIRE / X9166-B10B 22x22 mm ODF
9153-mm 803245 9152-mm 803287
28x28 mm ODM
7/8”x7/8” ODF
THRE X9144-B11B / B13B 9149 803284 9148 803283 22x22 mm ODF
1-1/8”x1-1/8” ODM

Flanges: 935- / ZZ-Series


Angle Style Straight Through Connection (Inlet x Outlet)
Valve Series Orifice Type
Type Part No. Type Part No. Metric Imperial
C501-5 803232 9761-3 803240 - 3/8”x5/8” ODF
X10-*01 / *02 / *03
C501-5mm 803233 9761-3mm 803241 10x16 mm ODF

C501-7 803234 9761-4 803350 1/2”x5/8” ODF


X10-*04 / *05
C501-7mm 803235 9761-4mm 803243 12x16 mm ODF -
935 / ZZ
6346-17 803330 16x22 mm ODF 5/8”x7/8” ODF
5/8”x7/8” ODF
A576 803238 - - -
X10-*06 / *07 7/8”x1-1/8” ODM
16x22 mm ODF
A576-mm 803239 - - -
22x28 mm ODM

221 GPC-EN-2024 CONTROLS COMPONENTS


GPC-EN-2024 CONTROLS COMPONENTS 222
223 GPC-EN-2024 CONTROLS COMPONENTS
Solenoid valves

Basic terms and technical information Formula for calculating the actual pressure drop of a solenoid valve:
∆p1 = ∆p2 x (Qn1/Qn2)2

Operating principles ∆p1: Actual pressure drop


∆p2: Nominal pressure drop at Qn1
Qn1: Calculated nominal capacity
Directly actuated: The magnetic field of the solenoid coil forces a
Qn2: Nominal capacity of selected valve
movement of the plunger and thus causes the opening of the valve seat.
Maximum Operating Pressure Differential (MOPD)
Servo actuated: The magnetic field of the solenoid coil is only uti­lized
MOPD is the maximum pressure differential between inlet and outlet
for the opening of the pilot valve seat. The necessary energy to actuate
of the solenoid valve which permits proper opening of the valve. When
the piston or diaphragm of the main valve seat is pro­vided by the
used with AC solenoid coils all solenoid valves employ 25 bar MOPD.
refrigerant flow and results in a certain pressure drop.
Operation in conjunction with DC solenoid coils lead to reduced MOPD
Minimum pressure drop
values depending on valve type and size. The DS2 Chopper Plugs
Directly actuated solenoid valves do not require a minimum pres­sure
allow the use of 24VAC coils with 24VDC by converting the DC in an AC
drop for proper operation.
voltage. Please contact Copeland application engineering for additional
details.
Servo operated solenoid valves require a minimum pressure drop
of approximately 0.05 bar to remain fully open. In case of insufficent
refrigerant flow, this value will not be reached and the solenoid valve
Type code
may close unintentionally. These closures may lead to malfunctions and
oscillations in the refrigeration circuit. Improper sizing of solenoid valves 200 RB 6 T 4
(i.e., use of excessively large solenoid valves) is the main cause of this
effect. This is particularly important in capacity controlled refrigeration
circuits.
Model Seat diameter T Solder Tube connection in
Series in multiples of F Flare multiple of 1/8” i.e. 1/2”
Therefore the decisive factor for proper solenoid valve sizing is the
1/16”. i.e. 3/8” or nearest mm equivalent
respective capacity of the valve and not its connection size.

Selection table for solenoid valves


Series
Selection Criteria 200 RB / 240 RA 540 RA
110 RB 200RC M36
200 RH 8/9/12/16T9 16T11/20 8/9/12/16 20
2-Way + + + + + + +
3-Way +
Normally Closed (NC) + + + +
Normally Open (NO) + +
Min. Pressure Differential (bar) 0.00 0.05 0.05 0.05 0.05 0.05 0.05
Maximum allowable pressure (bar) 31 31 / 60 (50*) 130 31 31 31 28 35
Media Temp. Range (°C) -40 / +120 -40 / +120 -40/ +120 -40 / +120 -40 / +120 -40 / +120 -40 / +120 -40 / +120
Coil Type ESC ESC ESC ESC ESC ESC ESC ESC

Note: * 200RH6T5

GPC-EN-2024 CONTROLS COMPONENTS 224


Coils ESC and cable assemblies
Standards
• ESC Coils and cable assemblies conform to Low Voltage Directive
Type Part No. Voltage Power Input Electr. Connection Protection

ESC-230V / 50 (60) Hz 801031


ESC-120V / 50 (60) Hz 801032 IP65
AC 8W without plug with plug /
ESC-24V / 50 (60) Hz 801033
see cable assemblies cable
ESC-M24V 863304 assembly
ESC-24V DC 801030 DC 15 W ESC
with plug and cable
DS2-N15 + ESC 24VAC 804620 + 801033 DC 3W IP65
assembly
Note: Coils are delivered with retainer kit. Please order cable assemblies separately.

Cable assemblies for ESC coils


Temperature Cable Wire Connector
Type Part No.
Range Length Diameter Type
ASC-N15 804 570 -50 .. +80°C 1.5 m
ASC-N30 804 571 for stationary use 3.0 m 3 x 0.75 mm2 loose wires
ASC-N60 804 572 only 6.0 m
ASC-N15
Note: Special cables for A2L applications. Check Technical Bulletin for details.

Other accessories
Type Part No. Description
ESC-K01 801 034 Screw cap (incl. 2x O-ring & fixing retainer)
PG9 Plug 801 012 Plug according to EN 175301 with cable gland PG 9

PG11 Plug 801 013 Plug according to EN 175301 with cable gland PG 11

225 GPC-EN-2024 CONTROLS COMPONENTS


2-way solenoid valves series 110, 200, 240 normally closed

Features
• Compact size
200 RC
• No disassembly necessary for soldering

Standards
110 RB
• 240 RA 16T11 and 20 are marked per PED

Accessories 240 RA
• Actuation coil and cable assemblies available for various
voltages, see ‘Coils ESC and Cable Assemblies’

Capacity data
Nominal Capacity (kW)
Liquid
Kv-Value ∆p Min
Type

R1234ze
R1234yf
(m3/h) (bar)
R407C

R454C
R404A

R450A

R452A

R454A

R455A

R513A

R448A

R449A
R134a

R507
R22

110 RB 2 3.5 3.8 2.5 3.6 3.3 2.5 3.2 2.8 3.0 3.1 2.6 3.2 3.3 3.2 0.2 0
200 RB 3 6.6 7.1 4.6 6.8 6.1 4.7 5.9 5.2 5.6 5.8 4.8 5.9 6.1 6.0 0.4
200 RB 4 15.5 16.8 10.9 16.1 14.5 11.0 14.0 12.4 13.1 13.8 11.4 13.9 14.5 14.2 0.9
200 RB 6 27.3 29.5 18.9 28.0 25.4 19.4 24.6 21.8 23.1 24.2 20.0 24.5 25.5 25.0 1.6
240 RA 8 36.3 39.3 25.2 37.3 33.8 25.8 32.7 29.0 30.7 32.2 26.6 32.6 34.0 33.3 2.3
0.05
240 RA 9 76.2 82.5 52.9 78.4 71.0 54.2 68.7 60.9 64.5 67.7 55.9 68.5 71.3 69.8 4.8
240 RA 12 85.7 92.8 59.5 88.1 79.9 61.0 77.3 68.6 72.5 76.1 62.9 77.0 80.2 78.6 5.4
240 RA 16 139.1 150.5 96.5 142.9 129.5 98.9 - - - 123.5 - 124.9 130.1 127.4 8.8
240 RA 20 202.6 219.3 140.7 208.3 188.7 144.1 - - - 179.9 - 182.0 189.6 185.7 12.8

Nominal Capacity (kW)


Hot Gas
Kv-Value ∆p Min
Type
R1234ze
R1234yf
R407C

R454C

(m3/h) (bar)
R404A

R450A

R452A

R454A

R455A

R513A

R448A

R449A
R134a

R507
R22

110 RB 2 1.6 2.0 1.7 2.1 1.4 111.8 2.0 1.8 2.0 1.5 1.3 1.3 2.0 2.0 0.2 0
200 RB 3 3.0 3.7 3.2 3.9 2.9 76.9 4.1 3.6 3.9 3.0 2.6 2.6 4.0 4.0 0.4 0.05
200 RB 4 7.1 8.8 7.5 9.2 6.5 47.2 9.2 8.1 8.8 6.8 5.9 5.8 9.1 9.0 0.9
200 RB 6 12.5 15.4 13.1 16.1 11.6 41.9 16.4 14.3 15.7 12.1 10.5 10.4 16.2 15.9 1.6
240 RA 8 16.7 20.5 17.4 21.4 16.6 20.1 23.5 20.6 22.5 17.3 15.1 14.9 23.2 22.9 2.3
240 RA 9 35.1 43.1 36.5 44.9 34.7 14.0 49.1 43.0 47.0 36.2 31.4 31.1 48.5 47.8 4.8
240 RA 12 39.4 48.4 41.1 50.5 39.0 7.9 55.2 48.4 52.8 40.7 35.4 35.0 54.5 53.8 5.4
240 RA 16 64.0 78.5 66.6 81.9 63.5 3.5 - - - 66.3 - 57.0 88.9 87.6 8.8
240 RA 20 93.2 114.4 97.1 119.3 92.4 1.7 - - - 96.4 - 82.9 129.3 127.5 12.8

Nominal Capacity Qn (kW)


Suction Gas
Kv-Value ∆p Min
Type
R1234ze
R1234yf

(m3/h) (bar)
R407C

R454C
R404A

R450A

R452A

R454A

R455A

R513A

R448A

R449A
R134a

R507
R22

240 RA 8 4.2 5.6 4.6 5.2 3.7 22.1 5.3 4.5 4.8 4.0 3.6 3.4 5.1 5.0 2.3
240 RA 9 8.8 11.7 9.7 10.9 7.8 15.2 11.2 9.4 9.9 8.4 7.6 7.1 10.6 10.5 4.8
240 RA 12 9.9 13.1 10.9 12.3 8.8 9.3 12.5 10.6 11.2 9.4 8.5 8.0 11.9 11.8 5.4 0.05
240 RA 16 16.0 21.3 17.7 19.9 14.3 8.3 - - - 15.3 - 13.1 19.4 19.2 8.8
240 RA 20 23.3 31.0 25.7 29.0 20.8 4.0 - - - 22.3 - 19.0 28.3 27.9 12.8
Note1: Nominal capacities at +38°C Condensing Temperature, +4°C Evaporating Temperature, Subcooling 1 K, Superheat 0K. 0.15 bar pressure drop between valve inlet and
outlet in liquid applications. 1 bar pressure drop for hot gas applications. +18 °C Suction Gas temperature.
For selection of other operating conditions, please use Copeland Select software.

GPC-EN-2024 CONTROLS COMPONENTS 226


Selection table
Connection Solder / ODF Special Versions:
Type Part No. • Manual stems standard on Series
mm Inch
240 RA 20.
T2 801 217 6
110 RB 2 T2 801 210 1/4 Options:
• Actuation coils available for various
T3 801 209 10
voltages, see ‘Coils ESC and Cable
200 RB 3 T3 801 239 10 Assemblies’
T3 801 176 10
T3 801 190 3/8
200 RB 4
T4 801 178 12
T4 801 179 1/2
T4 801 182 12
200 RB 6 T4 801 183 1/2
T5 801 186 16 5/8
T5 801 160 5/8
240 RA 8
T7 801 143 22 7/8
T5 801 161 16 5/8
240 RA 9 T7 801 162 22 7/8
T9 801 142 1-1/8
T7 801 163 22 7/8
240 RA 12
T9 801 144 1-1/8
T9 801 164 1-1/8
240 RA 16
T11 801 166 35 1-3/8
T11-M 801 172 35 1-3/8
T13-M 801 224 42
240 RA 20
T13-M 801 173 1-5/8
T17-M 801 174 54 2-1/8

227 GPC-EN-2024 CONTROLS COMPONENTS


2-way solenoid valves series 540 normally open

Features
• Compact size
• No disassembly necessary for soldering
• marking according to PED

540 RA
Accessories
• Actuation coil and cable assemblies available for various
voltages, see ‘Coils ESC and Cable Assemblies’

Capacity data - A1 refrigerants


Nominal Capacity Qn (kW)
Liquid Kv-Value ∆p Min
Type
(m3/h) (bar)
R404A
R134a R22 R407C R450A R513A R448A R449A R452A
R507
540 RA 8 36.3 39.3 25.2 37.3 33.8 32.2 34.0 33.3 25.8 2.3
540 RA 9 76.2 82.5 52.9 78.4 71.0 67.7 71.3 69.8 54.2 4.8
540 RA 12 85.7 92.8 59.5 88.1 79.9 76.1 80.2 78.6 61.0 5.4 0.05
540 RA 16 139.1 150.5 96.5 142.9 129.5 123.5 130.1 127.4 98.9 8.8
540 RA 20 202.6 219.3 140.7 208.3 188.7 179.9 189.6 185.7 144.1 12.8

Nominal Capacity Qn (kW)


Hot Gas Kv-Value ∆p Min
Type
R404A (m3/h) (bar)
R134a R22 R407C R450A R513A R448A R449A R452A
R507
540 RA 8 16.7 20.5 17.4 21.4 16.6 17.3 23.2 22.9 20.1 2.3 0.05
540 RA 9 35.1 43.1 36.5 44.9 34.7 36.2 48.5 47.8 41.9 4.8
540 RA 12 39.4 48.4 41.1 50.5 39.0 40.7 54.5 53.8 47.2 5.4
540 RA 16 64.0 78.5 66.6 81.9 63.5 66.3 88.9 87.6 76.9 8.8
540 RA 20 93.2 114.4 97.1 119.3 92.4 96.4 129.3 127.5 111.8 12.8

Nominal Capacity Qn (kW)


Suction Gas Kv-Value ∆p Min
Type
(m3/h) (bar)
R404A
R134a R22 R407C R450A R513A R448A R449A R452A
R507
540 RA 8 4.2 5.6 4.6 5.2 3.7 4.0 5.1 5.0 4.0 2.3
540 RA 9 8.8 11.7 9.7 10.9 7.8 8.4 10.6 10.5 8.3 4.8
540 RA 12 9.9 13.1 10.9 12.3 8.8 9.4 11.9 11.8 9.3 5.4 0.05
540 RA 16 16.0 21.3 17.7 19.9 14.3 15.3 19.4 19.2 15.2 8.8
540 RA 20 23.3 31.0 25.7 29.0 20.8 22.3 28.3 27.9 22.1 12.8

Capacity data - A2L refrigerants


Nominal Capacity Qn (kW)
Liquid Hot Gas Suction Gas
Kv-Value ∆p Min
Type
R1234ze

R1234ze

R1234ze
R1234yf

R1234yf

R1234yf
R454C

R454C

R454C
R454A

R455A

R454A

R455A

R454A

R455A

(m3/h) (bar)

540 RA 8 32.7 29.0 26.6 32.6 30.7 23.5 20.6 15.1 14.9 22.5 5.3 4.5 3.6 3.4 4.8 2.3 0.05

540 RA 9 68.7 60.9 55.9 68.5 64.5 49.1 43.0 31.4 31.1 47.0 11.2 9.4 7.6 7.1 9.9 4.8 0.05
540 RA 12 77.3 68.6 62.9 77.0 72.5 55.2 48.4 35.4 35.0 52.8 12.5 10.6 8.5 8.0 11.2 5.4 0.05
540 RA 16 - - - 124.9 - - - - 57.0 - - - - 13.1 - 8.8 0.05
540 RA 20 - - - 182.0 - - - - 82.9 - - - - 19.0 - 12.8 0.05
Note 1: Nominal capacities at +38°C condensing temperature. +4°C evaporating temperature. 0.15 bar pressure drop between valve inlet and outlet in liquid applications
(For hot gas applications 1 bar pressure drop and +18 °C suction gas temperature); Subcooling 1 K.
For selection of other operating condition, please use Copeland Select software.

GPC-EN-2024 CONTROLS COMPONENTS 228


Selection table

Connection Solder / ODF Options:


Type Part No. • Actuation coils available for various
mm Inch
voltages, see ‘Coils ESC and Cable
540 RA 8 T5 046 265 5/8 Assemblies’
T5 046 266 5/8
540 RA 9
T7 046 268 22 7/8
540 RA 12 T7 046 269 22 7/8
540 RA 16 T9 046 270 1-1/8
540 RA 20 T11 047 953 35 1-3/8

Accessories and spare parts for solenoid valves

Gasket kits Repair kits


Description Type Part No. Description Type Part No.
110RB KS 30040-2 801 232 110RB KS 30040-1 801 206
200RB/200RH KS 30039-1 801 233
240RA8 KS 30061-1 801 234 KS 30039/
200RB 801 205
KS 30109
240RA9/12 KS 30062-1 801 235
240RA16 KS 30065-1 801 236 240RA8 KS 30061 801 262
240RA20 KS 30097-1 801 237 240RA9 KS 30062 801 263
240RA12 KS 30063 801 264
Description Type Part No.
240RA16 KS 30065 801 200
Service tool for 110 RB,
X 11981 - 1 027 451
240 RA, 540 RA 240RA20 KS 30097 801 216

229 GPC-EN-2024 CONTROLS COMPONENTS


2-way solenoid valves series 200 RH
for high pressure applications , normally closed

Features

• Compact size
• Media temperature range -40 ... +120 °C
• No disassembly necessary for soldering
• Extended copper tubes for easy installation
• No disassembly necessary for brazing
• IP 65 solenoid coil and cable assembly
• One coil fits to all sizes and valve series
• Max. allowable pressure PS: 60 bar

Accessories
• Actuation coil and cable assemblies available for various voltages,
see ‘Coils ESC and cable assemblies’

Capacity data

Nominal Capacity Qn (kW)


Kv-Value ∆p Min
Type Liquid Hot Gas
(m3/h) (bar)
R410A R744 R452B R32 R454B R410A R744 R452B R32 R454B

200 RH 3 6.6 8.1 7.6 9.7 7.7 4.9 7.2 5.1 5.9 5.1 0.4
200 RH 4 15.7 19.1 18 23 18.2 11.0 16.1 11.4 13.4 11.4 0.9 0.05
200 RH 6 27.5 33.6 31.7 40.3 31.9 19.5 28.7 20.3 23.8 20.3 1.6
Note 1: R410A/R452B/R32/R454B: Nominal capacities at +38°C condensing temperature, +4°C evaporating temperature, subcooling 1 K
0.15 bar pressure drop between valve inlet and outlet in liquid applications.
1 bar pressure drop for hot gas applications

Note 2: R744: Nominal capacities at +10°C condensing temperature, -10°C evaporating temperature, subcooling 1 K
0.15 bar pressure drop between valve inlet and outlet in liquid applications.
1 bar pressure drop for hot gas applications

Note 3: For selection of other operating condition. please use Copeland Select software.

Selection table
Connection Solder / ODF Options:
Type Part No. • Actuation coils available for various voltages,
mm Inch
200 RH 3 T3 802 070 10 mm 3/8"
see ‘Coils ESC and Cable Assemblies’
T3 802 071 10 mm
T3 802 072 3/8"
200 RH 4
T4 802 073 12 mm
T4 802 074 1/2"
T4 802 075 12 mm
200 RH 6 T4 802 076 1/2"
T5 802 077 16 mm 5/8"

GPC-EN-2024 CONTROLS COMPONENTS 230


3-way solenoid valves series M36

Features
• For heat reclaim application
• Pilot connection to suction line required.
No minimum pressure drop
• Compact size
• No disassembly necessary for brazing
• Max. allowable pressure PS: 35 bar

Accessories
• Actuation coil and cable assemblies available
M36-118
for various voltages, see ‘Coils ESC and cable
assemblies’ M36-078

Capacity data

Nominal Capacity Qn (kW)

Hot Gas
Kv-Value ∆p Min
Type
(m3/h) (bar)

R1234ze
R1234yf
R407C

R454C
R404A

R450A

R454A

R454A

R448A

R449A

R452A

R455A
R134a

R507
R22

M36 28.9 35.1 31.3 30.4 38.5 26.4 36.7 36.7 32.3 36.2 35.7 31.4 35.1 24 23.9 6.7 0

Note 1: Nominal Capacities at +38°C Condensing Temperature. +4°C Evaporating Temperature (saturated pressures / dew point).
0.15 bar Pressure drop between valve inlet and outlet. For other operating conditions, please use Copeland Select software.

Selection table
Connection Solder / ODF
Type Part No. Coil Type
mm inch
M36-078 801420 22 7/8 ESC
M36-118 801421 1-1/8” ESC

Accessories and spare parts

Gasket kit Repair kit


Description Type Part No. Description Type Part No.
M36 KS30177-1 801268 M36 (upper assembly inc. gasket) M36-UNF 801440

231 GPC-EN-2024 CONTROLS COMPONENTS


GPC-EN-2024 CONTROLS COMPONENTS 232
233 GPC-EN-2024 CONTROLS COMPONENTS
Mechanical pressure regulators

Basic terms and technical information

Capacity regulators Crankcase pressure regulators

Regulator series ACP and CPHE are hot gas bypass regulators Series PRC regulators serve the purpose of preventing
and serve the purpose of compensating excess compressor excessively high suction pressures to protect compressor motors
capacity. Thus they prevent the generation of evaporator from overloading.
pressures below predetermined levels.
Excessively high suction pressures can occur at start-up of
In case of hot gas injection into the suction line, a liquid a refrigeration circuit in case of high loads and after defrost.
injection valve in conjunction with a solenoid valve is required Crankcase regulators are adjusted to the maximum allowed
to desuperheat the excessively hot suction gas. The capacity suction pressure rating of the compressors as given by the
should not be reduced below 60% of maximum in this application compressor manufacturers.
to avoid oil return problems.

With hot gas injection at the evaporator inlet, no liquid injection Selection guide for pressure regulators
valve is necessary. The injection must be such that the
incremental gas volume is taken into account. No problems with Series
Selection Criteria
oil return should be expected even when regulating 100% of ACP CPHE PRE PRC
capacity. Capacity Regulator + +
Evaporator Pressure
+
Evaporator pressure regulators Regulator
Crankcase Pressure
+
Series PRE regulators serve the purpose of maintaining Regulator
evaporator pressure above certain predetermined levels. The
most important application is the use of several evaporators
with different evaporating temperatures in conjunction with a
common suction line.

The freezing of water in water chillers and air conditioning


systems can be safely prevented if evaporating temperatures are
kept above 0°C, even when loads are greatly reduced.

GPC-EN-2024 CONTROLS COMPONENTS 234


Hot gas bypass regulators series ACP

Features
• High-quality materials and processes for high reliability and long lifetime
• Internal equalization
• Compact size

Technical data
Adjustment Range 0 ... 5 bar

Factory Setting 2.7 bar

Max. Allowable Pressure PS 31 bar

Medium Temperature Range TS –40 ... 120°C

Ambient Temperature Range -40 ... 50°C ACP

Transport Temperature Range -40 ... 70°C

Capacity data
Connection. Angle Nominal Bypass Capacity (kW)
Type Part No.
Solder/ODF inch R134a R22 R407C R404A / R507
ACP 1 047 680 1/4 x 3/8” 0.2 0.4 0.4 0.3
ACP 3 047 283 1/4 x 3/8” 0.5 0.8 0.9 0.7
ACP 5 053 374 3/8 x 3/8” 1.2 1.8 2.1 1.6
Note 1: Nominal capacities at +38°C condensing temperature. +4°C evaporating temperature (saturated temperatures / dew point) and
1 K liquid sub­cooling at the inlet of the expansion valve. For other operating conditions, please use Copeland Select software.

235 GPC-EN-2024 CONTROLS COMPONENTS


Hot gas bypass regulators series CPHE
Features
• High-quality materials and processes for high
reliability and long lifetime
• Superior partial load performance due to double
seat orifice design (CPHE3 to CPHE6)
• Modular design for economical logistics and easy
assembly and servicing
• External equalization

Specific connection sizes and flanges available on request.

For selection see last page of “Thermo-Expansion Valves” chapter. CPHE

Technical data
Adjustment Range -0.4 ... 5 bar

Factory Setting 1.4 bar

Max. Allowable Pressure PS 35 bar

Medium Temperature Range TS –40 ... 120°C

Ambient Temperature Range -40 ... 50°C

Transport Temperature Range -40 ... 70°C

Capacity data CPHE


Standard Flange
Nominal Bypass Capacity (kW)
Solder/ODF

Assembly
Power
R1234ze

Type Orifice
R404A /
R407C

R450A

R513A

R448A

R449A
R134a

R507
R22

mm Inch

C 501 - 7 mm C 501 - 7
CPHE - 1X 3.5 5.0 5.8 4.5 3.4 2.6 5.9 5.8 3.1 X 22440-B5B
12 x 16 1/2 x 5/8
A 576
A 576 mm
5/8 x 7/8
CPHE - 2X 6.4 9.0 10.4 8.1 6.2 4.8 10.6 10.5 5.6 X 22440-B8B 16 x 22
(7/8 x 1-1/8
(22 x 28 ODM)
ODM)
10331
10331 7/8 x 7/8
CPHE - 3X 12.0 17.0 20.0 15.0 12.0 9.0 20.0 20.0 10.0 X 11873-B5B X7818 - 1
22 x 22 (1-1/8 x
1-1/8 ODM)
CPHE - 3.5X 13.0 19.0 22.0 17.0 13.0 10.0 22.0 22.0 12.0 X 9117-B7B
9153 mm 9153
CPHE - 4X 16.0 23.0 27.0 21.0 16.0 12.0 27.0 26.0 14.0 X 9117-B9B
22 x 22 7/8 x 7/8
CPHE - 5X 21.0 29.0 34.0 26.0 20.0 15.0 35.0 34.0 18.0 X 9166-B10B
9149 9149
CPHE - 6X 35.0 50.0 58.0 45.0 34.0 26.0 59.0 58.0 31.0 X 9144-B13B
22 x 22 7/8 x 7/8
Note1: Nominal capacities at +38°C Condensing temperature, +4°C Evaporating temperature (saturated temperatures / dew point) and
1 K Liquid Sub­cooling at the inlet of the expansion valve. For other operating conditions, please use Copeland Select software.
Note2: Specific connection sizes and flanges available on request. For Selection, see last page of “Thermo-Expansion Valves” chapter.

GPC-EN-2024 CONTROLS COMPONENTS 236


Evaporator and crankcase pressure regulator series PRE and PRC
Features
• Compact design permits minimal space requirements
• Schrader valve on inlet for ease of setting
• Direct operated regulator
• Balanced port design provides accurate pressure control
• Copper tubes for easy soldering

Technical data
Refrigerants HFC. HCFC Pressure Change Per Turn:
Mineral, Alkyl Benzene and Valve Size 1 0.6 bar
Oil Compatibility Valve Size 2 0.4 bar
Polyol-Ester (POE) Lubricants
Max. Allowable Pressure PS 25 bar Pressure Range 0.5 ... 6.9 bar
Max. Test Pressure PT 30 bar Factory Setting 2 bar
Material Housing CW509L (EN12420)
Weight:
Storage -30 ... 80°C
PRC/PRE-1.. 0.6 kg
Temperature Range Medium TS -30 ... 80°C
PRC/PRE-2.. 1.3 kg
Ambient -30 ... 80°C

Evaporator pressure regulator series PRE

Selection table
Tube Connection Nominal Capacity (kW)
Type Part No.
ODF R134a R404A / R507 R407C R22
PRE - 11A 800 380 16 mm - 5/8”
3.0 4.5 4.5 4.8
PRE - 11B 800 381 22 mm - 7/8”
PRE - 21C 800 382 28 mm
7.4 11.1 11.1 11.9
PRE - 21D 800 383 1-1/8”
Note 1: Nominal Capacities are Based on Evaporating Temperature +4°C, Condensing Temperature +38°C and a Pressure Drop of 1K.
Note 2: For other operating conditions, please use Copeland Select software.

237 GPC-EN-2024 CONTROLS COMPONENTS


Crankcase pressure regulator series PRC
Selection
Tube Connection Nominal Capacity (kW)
Type Part No.
ODF R134a R404A / R507 R407C R22
PRC - 11A 800 384 16 mm - 5/8”
3.0 4.5 4.5 4.8
PRC - 11B 800 385 22 mm - 7/8”

PRC - 21C 800 386 28 mm


7.4 11.1 11.1 11.9
PRC - 21D 800 387 1-1/8”
PRC - 21E 800 388 35 mm - 1-3/8”
Note 1: Nominal Capacities are Based on Evaporating Tempera­ture +4°C and Condensing Temperature +38°C and a Pressure Drop of 1 K.
Note 2: For other operating conditions, please use Copeland Select software.

Capacity table

Evaporating Capacity (kW) Valve Setting °C


Refrigerant Temperature Valve Size 1: PRC-11x Valve Size 2: PRC-21x
°C -20 -15 -10 -5 0 +5 +10 -20 -15 -10 -5 0 +5 +10
-29 2.3 3.4 4.4 4.8 4.9 5.8 8.8 10.0 10.0 10.0
-21 2.4 4.1 5.4 5.8 6.5 12.1 12.1 12.1
R22 -14 2.7 4.9 6.2 8.1 13.8 13.8
-8 3.5 5.3 9.0 15.4
-3 3.1 9.9
-6 3.1 4.8 7.9 13.9
R407C
-1 2.9 9.2
-6 2.1 3.9 5.3 5.2 10.3 12.9
R134a 1 2.4 4.7 6.1 12.2
7 3.3 8.1
-27 1.6 2.9 3.7 3.9 4.8 8.2 8.2 8.2
R404A / -20 1.9 3.5 4.5 5.7 9.8 9.8
R507 -14 2.2 4.5 6.8 11.6
-10 3.1 8.1
Note: Selection for Operating Conditions other than +38°C / +4°C and 1 K Liquid Subcooling at the inlet of the valve: (Capacities are based on a Pressure Drop of 0.07 bar).

GPC-EN-2024 CONTROLS COMPONENTS 238


239 GPC-EN-2024 CONTROLS COMPONENTS
Pressure controls and thermostats

Pressure controls

Basic terms and technical information

Characteristics scale on the device is intended to serve for orientation, showing the
setting range of the upper switching point pmax in bar/psig and the
Pressure controls serve various functions, which may be divided value of the pressure differential ∆p as difference between upper
into control and protection functions. Examples for control functions switching point pmax and the lower switching point pmin. The upper
are compressor cycling, pump-down or defrost control. Protection switching point pmax has to be adjusted on the scale, whereas the
functions include pressure limiting and cut-out against excessive lower switching point pmin is given by adjustment of the desired
pressures, against loss of charge or for freeze protection. switching differential ∆p.
These functions are performed by operating a set of electrical The formula is:
contacts when exceeding a preset lower or upper pressure limit.
Depending on whether they are type tested (TÜV approved) or not,
they may be referred to by the following terms: Upper switching point - Differential =
Lower switching point
without TÜV approval: Pressure control
with TÜV approval: Pressure limiter, Pmax — ∆p = Pmin
Pressure cut-out or
Safety pressure cut-out Function of contacts SPDT
Pressure controls with TÜV approval are tested according to EN On pressure rise above setting 1-2 opens and
12263 as required by DIN 8901 and EN 378. 1-4 closes. On pressure drop below setting 1-2
closes and 1-4 opens. P
1. Pressure controls (without TÜV approval)
Pressure controls without type approval may either be of the
automatic or manual reset type. Manual reset versions are
SPDT with manual reset max.
available for decreasing (manual reset min.) or increasing
pressure (manual reset max.). On pressure rise above setting 1-2 opens and
1-4 closes and latches. The device can be
2. Pressure limiters PSL/PSH manually reset when the pressure has dropped
P
Pressure limiters are of the automatic reset type. Limiters for high below setting.
pressure applications have a double bellows design to act as
fail-safe controls.
SPDT with manual reset min.
3. Pressure cut-outs PZH/PZL On pressure drop below setting 1-2 closes, 1-4
Pressure cut-outs are of the manual reset type where reset is opens and latches. The device can be manually
possible from the outside of the control without the need for reset when the pressure has risen above P
a tool (external reset). Cut-outs for high pressure applications setting.
have a double bellows design to act as fail-safe controls.

4. Safety pressure cut-outs PZHH/PZLL Unit of pressure


Pressure cut-outs are of the manual reset type where the reset All pressures are given in gauge pressure
requires the use of a tool. Typically, the removal of a cover Pabsolute = Pgauge + 1 bar
is required in order to press the reset button (internal reset).
Cut-outs for high pressure applications have a double bellows 1 bar = 100 kPa
design to act as fail-safe controls. 1 bar = 14.5 psi
Pulsation damping
Adjustment of switching points All high pressure controls with connection (7/16-20UNF. 1/4” SAE
A pressure gauge should always be used for comparison when male) are equipped with a snubber to protect the pressure element
adjusting the switching points on pressure controls. The setting from pulsations.

GPC-EN-2024 CONTROLS COMPONENTS 240


Standards and regulations

BGV D4 (VBG20) Accident prevention regulations for refrigeration plant.

Heat pumps with fluorocarbon refrigerants. Protection of soil,


DIN 8901
underground and surface water.

EN 60947-1/ EN 60947-5-1 Specifications for low-voltage switch gear.

EN 378 Refrigerating systems and heat pumps - safety and environmental requirements.

EN 12263 Refrigerating systems and heat pumps - safety switching devices for limiting the pressure requirements and tests.

Selection table for pressure controls


Selection Criteria
Rated Operational Current
Series Number of Protection at 230 V AC
Design Contacts Adjustable DIN 40050
(SPDT) IEC 529 Inductive Amp. Motor Rating
AC 15 UL
PS1 / CS1 (for CO2 Pressure control
1 yes IP 44 10 A 24 A
applications) (single packaging) model
Dual pressure control
PS2 1+1 yes IP 44 10 A 24 A
(single packaging)

Pressure controls
Factory set to fixed
standard types 1 IP 30 / IP 65 3A 6A
values
(single packaging)
PS3
Pressure control Other fixed values
special types 1 acc. to agreed IP 30 / IP 65 3A 6A
(100 pieces packaging) specification
Pressure controls
Factory set to fixed
standard types 1 IP 30 / IP 65 3A 6A
CS3 values
(60 pieces packaging)
(for CO2
applications) Pressure control Other fixed values
special types 1 acc. to agreed IP 30 / IP 65 3A 6A
(60 pieces packaging) specification
Pressure controls
Factory set to fixed IP67 (cable) IP00
PS4 standard types (SPST) 6A 6A
values (terminals)
(100 pieces packaging)
Differential pressure Yes pressure diff. +
FD 113 1 IP 30 3A/6A ­-
control time delay

241 GPC-EN-2024 CONTROLS COMPONENTS


Pressure controls series PS1 / PS2
Features
• Adjustable pressure setpoint
• Automatic and manual reset versions
• Flare and solder pressure connections
• Chatter-resistant (bounce-free) contacts
• High operational current, locked rotor max. PS2 PS1
144 A (LRA)
• Standard SPDT with same operational current rating for Standards
both contacts
• Dual pressure control with independent SPDT switches • per Low Voltage Directive
(single pole double throw) for high and low pressure side
• Locking plate and mounting screws included • per PED Directive. TÜV appr. versions only

• Underwriter Laboratories (File Nr. E85974)


Options (minimum order quantity 100 pieces)
• Convertible reset to reduce stock
• Other types of pressure connections upon agreement
• Factory set to customer specification

Selection table single pressure controls PS1


Adjustment Range Lowest Factory Leakage Test
Pressure
Type Part No. Setpoint Setting Pressure
Upper Setpoint Differential Connection
(bar) (bar) (bar)
(bar) (bar)
Low Pressure Controls
PS1-A3A 4 370 700 7/16“-20 UNF
PS1-A3U 4 712 201 -0.5 … 7 0.5 … 5 -0.9 3.5 / 4.5 24 solder tube 6 mm
PS1-A3X 4 713 430 solder tube 1/4“
External reset
PS1-R3A 4 350 100 -0.5 … 7 approx. 1 bar -0.9 3.5 24 7/16“-20 UNF
above setpoint
High Pressure Controls
PS1-A5A 4 350 500 7/16“-20 UNF
PS1-A5L 4 715 136 cap./solder tube 1/4“
6 … 31 2 … 15 3 16 / 20 35
PS1-A5U 4 713 325 solder tube 6 mm
PS1-A5X 4 713 434 solder tube 1/4“
Ext. manual reset
PS1-R5A 4 350 700 6 … 31 spprox. 3 bar - 20 35 7/16“-20 UNF
below setpoint

GPC-EN-2024 CONTROLS COMPONENTS 242


Selection table single pressure controls PS1 TÜV (EN 12263)
Adjustment Range Lowest Factory Leakage Test
Pressure
Type Part No. Upper Setpoint Differential Setpoint Setting Pressure
Connection
(bar) (bar) (bar) (bar) (bar)

Pressure Limiter for Low Pressure Protection PSL - Automatic Reset


PS1-W3A 4 368 300 7/16”-20 UNF
-0.5 … 7 0.5 … 5 -0.9 3.5 / 4.5 24
PS1-W3U 4 713 437 solder tube 6 mm
Pressure Cut Out for Low Pressure Protection PZL - External Manual Reset
PS1-B3A 4 470 400 Reset Approx. 7/16”-20 UNF
-0.5 … 7 1 bar Above -0.9 3.5 24
PS1-B3U 4 715 141 Setpoint solder tube 6 mm

Pressure Limiter for High Pressure Protection PSH - Automatic Reset


PS1-W5A 4 353 200 7/16”-20 UNF
6 … 31 2 … 15 3 16 / 20 35
PS1-W5U 4 713 439 solder tube 6 mm
Pressure Cut Out for High Pressure Protection PZH - External Manual Reset
PS1-B5A 4 353 300 Reset Approx. 7/16”-20 UNF
6 … 31 3 bar Below - 20 35
PS1-B5U 4 712 332 Setpoint solder tube 6 mm

Safety Pressure Cut Out for High Pressure Protection PZHH - Internal Manual Reset (with tool)
PS1-S5A 4 368 400 Reset Approx. 7/16”-20 UNF
6 … 31 3 bar Below - 21 35
PS1-S5U 4 711 591 Setpoint solder tube 6 mm

Technical data PS1/PS2/CS1


- PS1/CS1: 1 x SPDT contact
Type of Contacts
- PS2: 2 x SPDT contacts Protection Acc. EN 60529 / IEC 529 IP 44
Resistive load (AC1) 24 A / 230 V AC
Inductive load (AC15) 10 A / 230 V AC
Inductive load (DC 13) 0.1 A / 230 V DC Ambient Temperature Range
-50 ...+70°C
3 A / 24 V DC Max. Temperature at +70°C
6 A / 12 V DC Pressure Connection
Motor rating UL (FLA) 24 A / 120 / 240 V AC
Startup / Locked Rotor UL 144 A / 120 / 240 V AC
Cable Entry Grommet PG 16
A1: R448A, R449A, R513A,
R450A, R134a, R452A, R23,
R410A, R407C, R404A, R507,
R124 Locking Device Blocking Plate
Medium Compatibility
A2L: R32, R452B, R454B,
R454A, R454C, R455A, Mounting Screws M4 / UNC 8-32
R1234yf, R1234ze
Note: For A2L applications please check the Operating Instructions.

243 GPC-EN-2024 CONTROLS COMPONENTS


Dual pressure controls series PS2

PS2

Selection table dual pressure controls PS2

Adjustment Range Leakage Test


Factory Setting
Pressure Pressure
Type Part No. (bar)
Upper Setpoint (bar) Differential (bar) (bar) Connection

Left Right Left Right Left Right Left Right

Combined Low and High Pressure Controls (automatic and manual reset)

PS2-A7A 4 353 400 7/16”-20 UNF

PS2-A7U 4 713 415 -0.5 … 7 6 … 31 0.5* ... 5 ca. 4 fix 3.5 / 4.5 20 24 35 solder tube 6 mm

PS2-A7X 4 713 416 solder tube1/4”

external
PS2-L7A 4 351 100 manual 7/16”-20 UNF
reset
-0.5 … 7 6 … 31 0.5* ... 5 3.5 / 4.5 20 24 35
approx. 4
PS2-L7U 4 713 417 bar under solder tube 6 mm
setpoint

external external
PS2-R7A 4 351 300 manual manual 7/16”-20 UNF
reset reset
-0.5 … 7 6 … 31 3.5 20 24 35
approx. 1 approx. 4
PS2-R7U 4 713 419 bar above bar below solder tube 6 mm
setpoint setpoint

Combined Low and High Pressure Controls, High Side Convertible from Automatic to Manual Reset

PS2-M7A 4 361 300 -0.5 .. 7 6 … 31 0.5* ... 5 - 3.5 / 4.5 21 24 35 7/16”-20 UNF

Selection table - dual pressure controls PS2 TÜV (EN12263)


Adjustment Range Leakage Test
Factory Setting
Pressure Pressure
Type Part No. (bar)
Upper Setpoint (bar) Differential (bar) (bar) Connection

Left Right Left Right Left Right Left Right


Combined Pressure Limiter for Low Pressure / High Pressure protection EN 12263
PSL / PSH (Automatic / Automatic)
PS2-W7A 4 360 100 7/16”-20 UNF

PS2-W7L 4 450 300 -0.5 … 7 6 … 31 0.5*... 5 ca. 4 fix 3.5 / 4.5 20 24 35 cap./solder 1/4”

PS2-W7U 4 712 436 Solder 6 mm


Combined Pressure Limiter / Pressure Cut-Out for Low Pressure / High Pressure Protection
PSL / PZH (Automatic / External Manual Reset)
external
manual
reset
PS2-C7A 4 353 500 -0.5 … 7 6 … 31 0.5* ... 5 3.5 / 4.5 20 24 35 7/16”-20 UNF
approx. 4
bar below
setpoint
Combined Pressure Limiter Safety Pressure Cut Out for Low Pressure / High Pressure Protection
EN 12263 PSL / PZH (Automatic / Automatic Convertible to External Manual Reset)
PS2-N7A 4 715 756 -0.5 .. 7 6 … 31 0.5* ... 5 - 3.5 / 4.5 21 24 35 7/16”-20 UNF
Note: *) Lowest Possible Setpoint: -0.9 bar

GPC-EN-2024 CONTROLS COMPONENTS 244


Selection table - dual pressure controls PS2 TÜV (EN12263)

Adjustment Range Leakage Test


Factory Setting
Pressure Pressure
Type Part No. (bar)
Upper Setpoint (bar) Differential (bar) (bar) Connection

Left Right Left Right Left Right Left Right


Combined Pressure Limiter / Safety Pressure Cut-Out for Low Pressure / High Pressure Protection
PSL / PZHH - Automatic / Internal Manual Reset

PS2-T7A 4 368 500 Internal reset 7/16”-20 UNF


-0.5 … 7 6 … 31 0.5* ... 5 approx. 4 bar 3.5 / 4.5 21 24 35
PS2-T7U 4 713 424 below setpoint solder tube 6 mm

Combined Pressure Cut-Out for Low Pressure / High Pressure Protection


PZL / PZH External Manual Reset / External Manual Reset
External reset
PS2-B7A 4 360 200 Internal reset 7/16”-20 UNF
approx.
-0.5 … 7 6 … 31 approx. 4 bar 3.5 20 24 35
1 bar above
PS2-B7U 4 449 400 below setpoint solder tube 6 mm
setpoint
Combined Pressure Cut-Out / Safety Pressure Cut-Out for High Pressure Protection
PZH / PZHH External Manual Reset / External Manual Reset
PS2-G8A 4 368 600 External 7/16”-20 UNF
Internal manual
manual reset
PS2-G8U 4 713 427 reset approx. solder tube 6 mm
6 … 31 6 … 31 approx. 20 21 35 35
4 bar below
4 bar below
PS2-G8X 4 713 428 setpoint Solder 1/4”
setpoint
Note: *) Lowest Possible Setpoint: -0.9 bar

245 GPC-EN-2024 CONTROLS COMPONENTS


Pressure controls series CS1
CS1 is an adjustable safety pressure for application in refrigeration
systems in compliance with standard EN 378.

Features
• Adjustable pressure range
• Narrow adjustable differential
• Range and differential pointer in units bar and psig
• High rated SPDT contacts for all versions
• Chatter resistant bounce free contacts
• Captive terminal and cover screws CS1
• 2 million cycles reliability (TÜV approved according to
EN 12263 to meet requirements of EN 378)
• Locking plate and mounting screws included

Options Standards
• Customer specific types available, minimum order • acc. PED 2014/68/EU & LVD 2014/35/EU
quantity 100 pieces

Selection table - pressure limiter for high pressure protection EN 12263 PSH (automatic reset)
Adjustment Range Max.
Lowest Setpoint Factory Test
Allowable Pressure
Type Part No. Upper Setpoint (Cut-in) Setting Pressure
Differential Setpoint Pressure PS Connection
(cut-out) (bar) (bar) (bar)
(bar) (bar)
(bar)
812004/
CS1-W6A 10...45 4 - 10 6 28 / 20 70 77
812004M* 7/16”-20 UNF
812005/ male
CS1-W7A 15...65 5 - 10 10 40 / 32 70 77
812005M*

Accessories PS1, PS2, CS1

Mounting Mounting Plate for


Extension Bracket
Bracket Angle Units with Hood
Part No.: 803 800
Part No.: 803 799 Part No.: 803 801

Copper Gasket Set for R 1/4”


Universal
Locking Plate (7/16”-20 UNF. Female)
Mounting Bracket
Part No.: 803783 (20 pcs) 100 pcs Package
Part No.: 803 798
Part No.: 803 780

GPC-EN-2024 CONTROLS COMPONENTS 246


Pressure controls series PS3 / standard types
Fixed settings in single packaging

Features
• Max. allowable pressure up to 45 bar / test pressure up to 50 bar
• High and low pressure switches
• High temperature version with snubber for direct compressor mounting (range 6)
• Direct mounting reduces the number of joints and thus avoiding potential leakage
• Precise setting and repeatability
• IP 65 protection if used with PS3-Nxx cables with plug
(acc. EN 175301-803), no additional gasket required (molded into plug)
• Cables with plug to be ordered separately PS3
Standards

• per Low Voltage Directive

• per PED Directive, TÜV appr.


versions only

• Underwriter Laboratories (File No. E85974)


(Released for 43 bar)

Selection table PS3- standard types

Fixed setting Max. Temperature


Pressure Leakage Test Pressure
Part No. Reset
Control Type Pressure Pressure Connection
Cut-out Cut-in Ambient
Connection

High Pressure Controls

PS3-A6S 0 715 603 16.0 bar 11.0 bar 7/16”-20UNF


Female
PS3-A6S 0 715 604 19.0 bar 15.0 bar Auto +70°C +150°C 50 bar Thread with
Schrader
PS3-A6S 0 715 600 26.5 bar 22.5 bar Opener
Low Pressure Controls / Pressure Limiter for Low Pressure Protection
PSL TÜV / EN 12263

PS3-W1S 0 714 760 -0.3 bar 1.2 bar 7/16”-20UNF


Female
PS3-W1S 0 714 761 0.3 bar 1.8 bar Auto +70°C +70°C 30 bar Thread with
Schrader
PS3-W1S 0 714 762 2.0 bar 3.5 bar Opener
Pressure Limiter for High Pressure Protection
PSH with snubber for direct compressor mounting TÜV / EN 12263
PS3-W6S 0 715 831 14.0 bar 10.0 bar
PS3-W6S 0 715 556 21.0 bar 16.0 bar 7/16”-20UNF
Female
PS3-W6S 0 715 555 25.0 bar 20.0 bar Thread with
Auto +70°C +150°C 50 bar
PS3-W6S 0 715 567 29.0 bar 23.0 bar Schrader
Opener and
PS3-W6S 0 715 550 33.5 bar 27.5 bar Snubber
PS3-W6S 0 715 553 40.0 bar 33.0 bar
Pressure Cut-Out for High Pressure Protection
PZH with Snubber for Direct Compressor Mounting TÜV / EN 12263
PS3-B6S 0 715 568 19.2 bar
7/16”-20UNF
PS3-B6S 0 715 564 22.7 bar Female
Approx. 5 bar External Thread with
PS3-B6S 0 715 563 27.3 bar +70°C +150°C 50 bar
below cut-out manual reset Schrader
PS3-B6S 0 715 569 29.5 bar Opener and
Snubber
PS3-B6S 0 715 560 36.0 bar

247 GPC-EN-2024 CONTROLS COMPONENTS


Accessories cable assemblies

Temperature
Type Part No. Length Leads
Range

PS3-N15 804 580 1.5 m


-50...80°C
PS3-N30 804 581 3.0 m 3 x 0.75 mm2
/ No UL
PS3-N60 804 582 6.0 m
Note: PS3-M… are not in compliance with EN60335-1/2-40,
clause 30 in term of glue wire test.

Plug According to EN 175301 Part No.


PG9 801 012
PG11 801 013

Technical data
IP 00 Temperature Range TS *
Protection According to IP 30 with Terminal Cover Ambient. Storage and -40 ... 70 °C
EN 60529 / IEC 529 IP 65 with PS3-Nxx Cables Transportation Medium -40 ... 70 °C (150°C Range 6)
with Plug or Plug DIN 43650

Inductive Load (AC15) 3 A / 230 V AC Pressure Range PS - 0.6 .. 43 bar

Inductive Load (DC) 0.1 A / 230 V DC Type of Contacts 1 SPDT


Motor Rating Amps (FLA) 6 A / 120/240 V AC
HFC, HCFC, HFO/HFO Blends
Medium Compatibility
Lock Rotor Amps (LRA) 36 A / 120/240 V AC (refrigerant safety group A1)

Maximum Ambient Temperature (°C)


70

60

50
Note: *) For high temperature applications, i. e., medium temperatures between 70 °C and 150 °C,
the maximum ambient temperature must be derated as per drawing. E.g.: on medium temperature
40 120 °C the ambient temperature of 55 °C around the switch housing should not be exceeded.

30
70 80 90 100 110 120 130 140 150

Medium Temperature (°C)

GPC-EN-2024 CONTROLS COMPONENTS 248


Pressure controls series PS3/PSC special types

Features
• Maximum allowable pressure up to 45 bar / test pressure up
to 50 bar
• For direct mounting on a pressure connection (free standing)
or with a capillary tube
• Direct mounting reduces the number of joints and thus
avoids potential leakage
• Direct mounting saves cost for flexible hose and
additional fittings
• Precise setting and repeatability PS3
• High temperature version with snubber, for direct compressor
mounting (range 6)
• Micro switch for narrow pressure differentials
• Gold plated contacts for low voltage / current applications
Standards
• Worldwide approvals
• per Low Voltage Directive
• Easy mounting
• Housing with integrated console for free-standing installation • per PED Directive TÜV appr. versions only
• Low pressure switch with automatic or manual reset
• High pressure switch with automatic or manual reset, • Underwriter Laboratories (File No. E85974)
standard or high temperature version (Released for 43 bar)
• Pressure limiter PSH - standard or high temperature version
• Pressure cut-out PZH - external reset, standard or high
temperature version
Pressure connections
• Safety pressure cut-out PZHH - internal reset, standard or
high temperature version • S: 7/16”-20UNF, female with Schrader opener and snubber
• Cables with plug in lengths of 1.5m, 3.0m and 6.0m available. (snubber only with high temperature diphragm)
No additional gasket required. • A: 7/16”- 20UNF, 1/4” SAE male
• Appliance socket DIN 43650 • U: 6 mm solder. 80 mm length. ODF
• Electrical contact single pole double throw • X: 1/4” solder. 80 mm length. ODF
• Electrical micro switch single pole double throw (SPDT) • K: 1 m capillary tube with 1/4” SAE flare nut and Schrader
• Gold plated contacts upon request opener
• According to agreed specification, 100 pieces packaging • L: 1 m capillary tube and 1/4” ODM solder connector

Technical data
IP 00 36 A / 120/240V AC
Lock Rotor Amps (LRA)
Protection According to IP 30 with Terminal Cover 15 A with Microswitch
EN 60529 / IEC 529 IP 65 with PS3-Nxx Cables with
Plug or Plug DIN 43650 Temperature Range TS
-40 ... 70°C
Ambient. Storage and
-40 ... 70°C (150°C Range 6)
3 A / 230V AC Transportation Medium
Inductive Load (AC15) 1.5 A with Microswitch Standard
0.1 A with Gold Plated Contacts Pressure Range PS - 0.6 .. 43 bar

Inductive Load (DC) 0.1 A / 230V DC Type of Contacts 1 SPDT

6 A / 120/240V AC HFC, HCFC, HFO/HFO Blends


Motor Rating Amps (FLA) Medium Compatibility
2.5 A with Microswitch (refrigerant safety group A1)

Note: For more information see the technical bulletin of PS3

249 GPC-EN-2024 CONTROLS COMPONENTS


Pressure controls series CS3 for R744/ CO2
Standard types with fixed settings and special types,

Features
• Pressure range 8/Q
- Versions with fixed factory cut-out setting available
between 60 bar to 140 bar
- Maximum allowable pressure of 140 bar
- Factory test pressure of 154 bar
- Narrow differential (approx. 6 bar) between cut-out and cut-in
(in Microswitch version) CS3
• Pressure range 7/P
- Versions with fixed factory cut-out setting available
between 40 bar to 70 bar
- Maximum allowable pressure of 90 bar
- Factory test pressure of 100 bar
- Narrow differential (approx. 4 bar) between cut-out and cut-in
(in Microswitch version)
• Manual reset versions available Applied standards
• Precise switching and repeatability; Snap Action Contacts =>
Chatter Free (Bounce free) and Accurate Operation
• Contacts are designed as SPDT (Single pole double throw) for • per Low Voltage Directive
control function and alarm/status reporting
• Direct compressor mounting with adapter option • per PED Directive
• 2 million cycles reliability (TÜV EN 12263 approved)
• IP65 protection if used with PS3-Nxx with plug • Underwriter Laboratories (File No. E85974)
(acc. EN 175301-803), no additional gasket required
(molded into plug)
• 60 pieces packaging

Selection table

1. Standard types
Pressure range 8/Q
Part No. Fixed Setting
Pressure
Type (Multi-Pack 60 Reset Electrical Switch
Cut-out Cut-in Connection
Pcs)

Pressure Limiter
0718008M 106 bar 100 bar Micro Switch
CS3-WQS
Automatic
Pressure Limiter
0718009M 106 bar 80 bar Standard Switch
CS3-W8S 7/16”-20 UNF
Pressure Cut-out Approx. 25 bar Female Thread with
0718001M 108 bar External Manual Standard Switch Schrader Opener
CS3-B8S below cut-out

Safety Pressure
Approx. 25 bar
Cut-out 0718002M 108 bar Internal Manual Standard Switch
below cut-out
CS3-S8S

Pressure range 7/P


Part No. Fixed Setting
Type Reset Electrical Switch Pressure Connection
(Multi-Pack 60 Pcs) Cut-out Cut-in
Pressure Limiter
0718007M 54 bar 50 bar Micro Switch
CS3-WPS
Automatic
Pressure Limiter
0718006M 54 bar 41 bar Standard Switch
CS3-W7S 7/16”-20 UNF Female
Pressure Cut-out Approx. 13 bar Thread with Schrader
0718004M 54 bar External Manual Standard Switch Opener
CS3-B7S Below Cut-out
Safety Pressure
Approx. 13 bar
Cut-out 0718005M 54 bar Internal Manual Standard Switch
Below Cut-out
CS3-S7S
Note: Cables with plug must be ordered separately (see next page).

GPC-EN-2024 CONTROLS COMPONENTS 250


2. Pressure controls CS3 special type
According to agreed specification, 60 pieces packaging

Pressure Range 8/Q: Versions with fixed factory cut-out settings available between 60 bar to 140 bar
Pressure Range 7/P: Versions with fixed factory cut-out settings available between 40 bar to 70 bar

Accessories cable assemblies


Type Part No. No. of Leads Diameter of Lead Temperature Range Cable Length
PS3-N15 804 580 3 0.75 mm2 -50…+80 °C 1.5 m
PS3-N30 804 581 3.0 m
PS3-N60 804 582 6.0 m
Note: PS3-M… are not in compliance with EN60335-1/2-40, clause 30 in term of glue wire test

Plug According to EN75301 Part No.

PG9 801 012

PG11 801 013

Technical data
Protection Class IP 65 with PS3-Nxx Storage and Transportation
-40 …+70°C
Acc. to EN 60529 IP00 without Appliance Socket Temperature

Pressure Range 8/Q: 140 bar Ambient Temperature


Max. Allowable Pressure PS -40 …+70°C
Pressure Range 7/P: 90 bar (Housing)*

Pressure Range 8/Q: 154 bar Medium Temperature* -40 …+150°C


Factory Test Pressure PT
Pressure Range 7/P: 100 bar

Tolerances (As Per EN 12263) -


Only for Standard Types
(See page 1)
0 to -8%
Note: Tolerances are Valid
Between -20...+55°C.

Maximum Ambient Temperature (°C)


70
*) Note: For high temperature applications, i.e. medium temperatures
between 70°C and 150°C, the maximum ambient temperature must be
derated as per drawing. 60

E.g.: On medium temperature 120°C the ambient temperature of 55°C


around the switch housing should not be exceeded. 50

40

30
70 80 90 100 110 120 130 140 150

Medium Temperature (°C)

Electrical data
Standard (SPDT) Micro Switch (SPDT)

Inductive Load (AC15) 3 A / 230 VAC 1.5 A / 230 VAC

Inductive Load (DC) 0.1 A / 230 VDC 0.1 A / 230 VDC

Motor Rating Amps (FLA) 6 A / 120 / 240 VAC 2.5 A / 120 / 240 VAC

Lock Rotor Amps (LRA) 36 A / 120 / 240 VAC 15 A / 120 / 240 VAC

251 GPC-EN-2024 CONTROLS COMPONENTS


Pressure controls series PS4 with fixed settings for OEM applications

Features
• High- and low pressure switches
• Precise settings and repeatability
• Cable version with IP67 (IP20 for terminal version)
• Normally open/closed electrical contacts
(under standard operating conditions)
• TUV approved versions (W & B)
• UL approved
• Released for A2L applications, please check the
Operating Instructions
• Minimum order quantity 100 pieces

Standards
• According to Low Voltage Directive and European scheme ENEC05 PS4

• According to Electrical Equipment Directive 14/35/EU


• 0035 According to Pressure Equipment Directive 14/68/EU
• Underwriter Laboratories file Nr. E258370

Type code
PS4– W 1

Product name

Function Electrical Connection


A Pressure controls, automatic, 1 Silver contact with molded cable, normally closed (NC)
high pressure or low pressure 2 Silver contact with molded cable, normally open (NO)
W Pressure limiters, automatic 3 Silver contact with quick connector QC (for push-on spades),
type approval acc. EN 12263, normally closed (NC)
(EN 12263 & EN 378: PSL/ PSH) 4 Silver contact with quick connector QC (for push-on spades),
R Pressure controls, external manual normally open (NO)
reset (by hand) 5 Gold-plated contact with molded cable, normally closed (NC)
B Pressure limiters, external manual reset (by hand); L Silver contact with molded cable suitable for manual reset,
type approval, acc. EN 12263, normally closed (NC)
(EN 12263 & EN 378: PZH)

Selection table - low pressure switches with automatic reset; open on falling pressure
Setting Connector (QC) Test Pressure
Type Part No. EN 12263 Type of contact
Cut-out Cut-in Cable Pressure Connection

PS4-W1 808269 0.3 bar 1.5 bar 3.0 m PSL silver 6 mm brazing

PS4-A1 808266 0.4 bar 1.4 bar 1.5 m - silver 7/16-20UNF*

PS4-W1 808208 0.6 bar 1.8 bar 1.5 m PSL silver 7/16-20UNF*
PS4-W1 808251 0.6 bar 1.8 bar 3.0 m PSL silver 6 mm brazing
PS4-W5 808289 0.6 bar 1.8 bar 1.5 m PSL gold-plated 6 mm brazing
PS4-W1 808209 0.7 bar 2.1 bar 1.5 m PSL silver 7/16-20UNF*
PS4-W1 808241 0.7 bar 2.4 bar 3.0 m PSL silver 7/16-20UNF*
PS4-A1 808247 1.5 bar 2.5 bar 2.5 m - silver 7/16-20UNF*
25 bar
PS4-A1 808229 1.5 bar 3.0 bar 1.5 m - silver 7/16-20UNF*
PS4-W1 808210 1.7 bar 3.4 bar 1.5 m PSL silver 7/16-20UNF*
PS4-W1 808249 1.7 bar 3.4 bar 1.5 m PSL silver 6 mm Brazing
PS4-W1 808271 1.8 bar 3.2 bar 1.5 m PSL silver 7/16-20UNF*
PS4-A1 808276 3.3 bar 4.8 bar 1.5 m - silver 7/16-20UNF*
PS4-W3 808235 0.6 bar 1.8 bar QC PSL silver 7/16-20UNF*
PS4-W3 808284 1.2 bar 2.9 bar QC PSL silver 6 mm Brazing
PS4-W3 808243 1.7 bar 3.4 bar QC PSL silver 7/16-20UNF*
Note: *) 7/16-20UNF female with Schrader valve opener

GPC-EN-2024 CONTROLS COMPONENTS 252


Selection table - high pressure switches with automatic reset; open on rising pressure
Setting Connector (QC) Test Contact Pressure
Type Part No. EN 12263 Application
Cut-out Cut-in Cable Pressure Function Connection
PS4-W1 808200 18 bar 13 bar 1.5 m 7/16-20UNF*
PS4-W1 808265 18 bar 13 bar 3.0 m 6mm
PS4-W1 808201 26 bar 20 bar 1.5 m 7/16-20UNF*
PSH
PS4-W1 808224 26 bar 20 bar 3.0 m 41 bar
6mm
PS4-W1 808 282 24 bar 18 bar 5.0 m
PS4-W3 808236 26 bar 20 bar QC 7/16-20UNF*
PS4-A1 808260 26 bar 20 bar 1.5 m None 1/4”
PS4-W1 808203 28 bar 21 bar 1.5 m PSH
Open 7/16-20UNF*
PS4-A1 808233 28 bar 21 bar 1.5 m High
none on rising
PS4-A1 808244 28 bar 21 bar 1.5 m pressure 1/4”
pressure
PS4-W3 808273 29 bar 22.8 bar QC 55 bar PSH
PS4-A1 808237 29.5 bar 22.5 bar 1.5 m None
7/16-20UNF
PS4-A1 808238 31 bar 24 bar 1.5 m Female with
None
PS4-A1 808248 32 bar 24 bar 2.5 m Schrader
Opener
PS4-W1 808205 42 bar 33 bar 1.5 m
PSH
PS4-W3 808242 42 bar 33 bar QC
69 bar
PS4-W5 808287 45 bar 34 bar 1.5 m
6mm
PS4-W1 808261 45 bar 35 bar 1.5 m PSH

Selection table - high pressure switches with automatic reset; close on rising pressure
Setting Connector (QC) Test Contact Pressure
Type Part No. EN 12263 Application
Cut-Out Cut-in Cable Pressure Function Connection
PS4-A2 808212 13 bar 18 bar 1.5 m None
7/16-20UNF
PS4-W2 808274 14.6 bar 20 bar 1.5 m 41 bar PSH Close on
Female with
Rising Fan control
PS4-A2 808264 17 bar 22.6 bar 1.5 m None Schrader
Pressure
Opener
PS4-W2 808227 22 bar 28 bar 1.5 m 55 bar PSH

Selection table - high pressure switches with manual reset; open on rising pressure
Setting Connector (QC) Test Contact Pressure
Type Part No. EN 12263 Application
Cut-Out Cut-in Cable Pressure Function Connection

PS4-BL 808202 26 bar - 1.5 m 41 bar


Open on 7/16”-20UNF
high pressure
PS4-BL 808204 28 bar - 1.5 m 55 bar PZH Rising Female with
EN 378
Pressure Schrader Opener
PS4-BL 808206 42 bar - 1.5 m 55 bar

Technical data Electrical data


Cable or Terminal (QC)* Cable or Terminal Cable
Cable Version
Type Version (QC)* Version Version
PS4-A PS4-W PS4-B / PS4-R Type
PS4-B /
PS4-A PS4-W
Setting (bar) 0 - 6.9 7 - 27.6 27.7 - 38 38.1 - 50 13.8-27.6 27.7 - 38 38.1 - 50 PS4-R
PMAX / PS (bar) 25 41 55 69 41 55 68 0.1…6 A 0.1…6 A
Silver contact: 2A 2A
Fluid group /
I & II / A1 & A2L Refrigerants, Mineral-. 6A 3A
Refrigerants Synthetic-. POE-Lubricant Inductive Load 230 VAC 36 A 15 A
(ASHARE)
Inductive Load (DC <28V) 250 mA -
> 100.000 cycles
Life time Motor rating FLA 230 VAC
PS4-B… / PS4-R… versions 10.000 cycles (6.000 for UL approved)
Motor rating LRA 230 VAC
Vibration
4 g (10…250 Hz)
resistance Gold contact (12 / 24 VDC):
Temperature
Medium: -40 °C…+135 °C Ambient: -40 °C…+65 °C
range
Protection class IP67 (IP00 for Terminal QC
Hazard (IEC 529 / DIN 40050) Version)
Category (PED PS4-W.. & PS4-B…versions: IV / Module B + D
2014/68/EU) 18 AWG 0.8 mm2. 600 V (max.
Weight ~ 100 g Cable Version 125 °C)
Cable Colour Low pressure: (0…8.5 bar: blue)
Markings (LVD & ENEC05) 0035 (PED), High Pressure: (>8.5 bar: black)

253 GPC-EN-2024 CONTROLS COMPONENTS


Differential pressure controls series FD 113
Features
• Immediate reset (no cooling down period)
• Precise timing
• Adjustable time delay from 30 ... 150 sec (ZU types)
• Separate output signals for operation and alarm
• Suitable for supply voltage 24 ... 240 V AC / DC
• Pressure connection: Flare 7/16”-20 UNF, 1/4” SAE male

Standards

• per Low Voltage Directive FD 113

• File No. E85974

Time Delay Cut out Max.


Cut in Fixed Max. Proof
Type Part No. Factory Adjusting Factory Differential
Adjustable Setting Pressure
Setting Range Δp Setting Pressure

FD 113 0 710 173 - - 0.2 bar above


0.3 ... 4.5 bar 0.7 bar
FD 113 ZU 3 465 300 20 ... 150 s 120 s* cut- out

FD 113 ZU -0.8 ... 12 bar 25 bar


(A22-057)
Copeland 0 711 195 - 115 s* Fix - 0.63 bar Fix Appr. 0.9 bar
brand
products
Note: *) Time Delay tolerance +/- 20%.

Technical data
Inductive Amp. (AC) 3.0 A / 230 V AC

Inductive Amp. (DC) 0.1 A / 230 V DC

Protection Acc. to EN 60 529 IP 30

Max. Temperature at Pressure Connection +70°C

Accessories

Mounting Mounting Plate for Extension Bracket


Bracket Angle Units with Hood Part No.: 803 800
Part No.: 803 799 Part No.: 803 801

GPC-EN-2024 CONTROLS COMPONENTS 254


Thermostats

Basic terms and technical information

Characteristics Adjustment of switching points


Thermostats are electric circuit control devices which open or A thermometer should always be used for comparison when
close an electric contact depending on temperature changes at adjusting the switching points on temperature controls. The setting
the bulb. scale on the device is intended to serve for orientation, showing
the setting range of the upper switching point tmax in °C and °F
Description of bulb charges and the value of the temperature differential ∆t in K as difference
between the upper switching point tmax and the lower switching
The application range of thermostats is mainly determined by the point tmin. The upper switching point tmax has to be adjusted
charge. Accordingly, various bulb shapes and sizes are necessary. on the scale, whereas the lower switching point tmin is given by
adjustment of the desired switching differential ∆t. The formula is:
• Vapor charge, bulb type A, E, P
The thermosystem is filled with a medium in vapor phase. A Upper switching point – Differential =
thermostat with vapor charge operates in accordance with Lower switching point tmax – ∆t = tmin
temperature changes at the bulb as long as the bulb is the
coldest part in the whole system (bellows, capillary tube,
bulb). Copeland thermostats are equipped with a bellows Important!
heater (82 k Ohm, 230 V) to avoid such conditions. On
applications with low current the bellows heater has to be The differential ∆t mentioned on the differential scale and in the
removed. Max. bulb temperature is 150°C (70°C for bulb type technical data refers to the upper part of the setting range and
E). Response time is very fast. the upper switching point.

• Adsorption charge, bulb type F In the lower part of the setting range an increase of the differential
This charge only reacts on temperature changes at the bulb. ∆t can be expected. The lowest possible lower switching
Max. bulb temperature is 100°C. Response time is slow but point tmin is mentioned in the selection tables and is helpful to
perfectly suitable for common refrigeration systems. select switching points with large differentials ∆t in the lower
temperature range.

255 GPC-EN-2024 CONTROLS COMPONENTS


Bulb sizes

A E P F

Vapor Vapor Vapor Adsorption


2 m, Capillary with Bulb Coil, 0 m 2 m, Capillary with 2 m, Capillary with Bulb
Function C and D 6 m

Function of contacts

SPDT SPDT with manual reset min. SPDT with manual reset max.
- On temperature rise above setting - On temperature drop below setting - On temperature rise above setting
1-2 opens and 1-4 closes. 1-2 closes. 1-4 opens and latches. 1-2 opens and 1-4 closes and latches.
- On temperature drop below setting - The device can be manually reset when - The device can be manually reset when
1-2 closes and 1-4 opens. the temperature has risen at least 2K the temperature has dropped 2K below
above setting. setting.

SPDT with off switch SPDT with bellows heater


AUTO matic - STOP includes a 82 k Ohm, 230 V AC/DC resistor

Standards and regulations


Important for the installation of thermostats:

EN 60730-2-9 Specification for temperature controls and temperature cut-outs.

EN 60947-1/ Specifications for low-voltage switchgear.


EN 60947-5-1

GPC-EN-2024 CONTROLS COMPONENTS 256


Thermostats series TS1

Features
• Adjustable temperatures and differentials
• Chatter resistant contacts (bounce-free)
• High operational current, locked rotor max. 144 A (LRA) TS1 Flush Mounted
• Standard SPDT with same operational current rating for
both contacts
• Captive terminal and cover screws
• Range and differential individually lockable by wire seal

Technical data
Type of Contacts 1 SPDT
Heating Load (AC1) 24 A / 230 V AC TS1 Top Operated
Inductive Load (AC15) 10 A / 230 V AC
Inductive Load (DC13) 0.1 A / 230V DC, 3 A / 24 V DC
TS1 Front Operated
Motor Rating (FLA): 24 A / 120/240 V AC
Locked Rotor (LRA): 144 A / 120/240 V AC
Standards
Ambient Temperature Range -50 ... +70°C
Cable Entry Grommet PG 16 • per Low Voltage Directive

Protection Acc. to IP 44 • Underwriter Laboratories File Nr: E85974


EN 60529 / IEC 529 (IP 30 with Selector Switch)
82 KΩ. 230 V AC / DC
Bellows Heater at Vapor charge
(12 and 24 V DC upon request)
sensing range: -55...+180°C

Adjustment Range Temperature Sensor


Lowest Factory Max. Bulb
Type Part No. Upper Differential Cap. Tube
Setpoint Setting Temp. Charge
Setpoint Setpoint ∆T Length
Thermostats Top Operated
Thermostats without Off-Switch
TS1-A2P 4 530 400 -30 … +15°C 1.5 … 16 K -36°C -1°C / -6°C
+150°C Vapor 2 m Capillary
TS1-A3P 4 356 700 -10 … +35°C 1.5 … 16 K -23°C +3°C / -2°C
TS1-A1A 4 351 500 -45 … -10°C 1.5 … 16 K -55°C -18°C / -20°C
TS1-A2A 4 351 600 -30 … +15°C 1.5 … 16 K -36°C -1°C / -6°C +150°C Vapor
TS1-A3A 4 352 500 -10 … +35°C 1.5 … 16 K -23°C +3°C / -2°C
2 m Capillary
TS1-A4F and Bulb
Defrost- and
4 351 800 -30 … +35°C 2.8 … 20°C -35°C +5°C / 0°C
Universal Ther- +100°C Adsorption
mostat

TS1-A5F 4 458 400 +20 … +60°C 3 … 10 K +10°C +35°C / +30°C


Thermostats with Off-Switch
TS1-B2A 4 366 800 -30 … +15°C 1.5 … 16 K -36°C -1v / -6°C
TS1-B3A 4 366 900 -10 … +35°C 1.5 … 16 K -23°C +3°C / -2°C +100°C Adsorption
TS1-B4F 4 367 000 -30 … +35°C 2.8 … 20 K -35°C +5°C / 0°C

Frost Monitors Top Operated


Frost Monitors without Off-Switch

TS1-C0P 4 352 100 +4.5 … +20°C 2.5 K fix +2°C 4,5°C / +2°C
TS1-D0P +150°C Vapor 6 m Capillary
Man. Reset
Low Temp. 4 352 200 +4.5 … +20°C +2°C +2°C
ca. 2.5 K fix
Cut Out

257 GPC-EN-2024 CONTROLS COMPONENTS


Adjustment Range Temperature Sensor
Lowest Factory Max. Bulb
Type Part No. Upper Differential Cap. Tube
Setpoint Setting Temp. Charge
Setpoint Setpoint ∆T Length

Room Thermostats Top Operated


Room Thermostats without Off-Switch, Including Insulation Console

0m
TS1-A3E 4 355 300 -10 … +35°C 1.5 … 16 K -23°C +20 / +18°C +70°C Vapor
coil

Room Thermostats with Off-Switch, Including Insulation Console

0m
TS1-B3E 4 344 500 -10 … +35°C 1.5 … 16 K -23°C +20 / +18°C +70°C Vapor
coil

Thermostats Front Operated


Thermostats without Off-Switch

TS1-E1A 4 361 000 -45 … -10°C 2 … 16 K -55°C -18 / -20°C

TS1-E2A 4 356 200 -30 … +10°C 1.5 … 15 K -36°C +4 / +2°C +150°C Vapor

TS1-E3A 4 365 200 -10 … +25°C 1.5 … 15 K -23°C +3 / -2°C


2 m capillary
TS1-E4F and bulb
Defrost- and
4 367 500 -25 … +30°C 2.8 … 20 K -30°C +5 / 0°C
universal +100°C Adsorption
thermostat

TS1-E5F 4 338 100 +20 … +60°C 3 … 10 K +10°C +35 / +30°C

Thermostats with Off-Switch

TS1-F1A 4 367 100 -45 … -10°C 2 … 16 K -55°C -18 / -20°C


2 m capillary
TS1-F2A 4 367 200 -30 … +10°C 1.5 … 15 K -36°C -1 / -6°C +150°C Vapor
and bulb
TS1-F3A 4 367 400 -10 … +25°C 1.5 … 15 K -23°C +3 / -2°C

Room Thermostats Front Operated


Room Thermostats without Off-Switch, Including Insulation Console

TS1-E1E 4 365 300 -45 … -10°C 2 … 16 K -55°C -18 / -20°C 0m


+70°C Vapor
TS1-E2E 4 356 800 -30 … +10°C 1.5 … 15 K -36°C +4 / +2°C coil

Room Thermostats with Off-Switch, Including Insulation Console

TS1-F1E 4 368 000 -45 … -10°C 2 … 16 K -55°C -18 / -20°C


0m
TS1-F2E 4 368 100 -30 … +10°C 1.5 … 15 K -36°C +4 / +2°C +70°C Vapor
coil
TS1-F3E 4 368 200 -10 … +25°C 1.5 … 15 K -23°C +20 / +18°C

Thermostats for Flush Mounting


Thermostats for Flush Mounting without Off-Switch

TS1-G2A 4 355 400 -30 … +15°C 1.5 … 15 K -36°C +4 / +2°C +150°C Vapor

TS1-G4F 2 m capillary
Defrost- and and bulb
4 355 600 -30 … +35°C 2.8 … 20 K -35°C +5 / 0°C +100°C Adsorption
universal
thermostat

Thermostats for Flush Mounting with Off-Switch

TS1-H2A 4 355 500 -30 … +15°C 1.5 … 15 K -36°C -1 / -6°C 2 m capillary


+150°C Vapor
TS1-H3A 4 367 900 -10 … +35°C 1.5 … 15 K -23°C +3 / +2°C and bulb

GPC-EN-2024 CONTROLS COMPONENTS 258


Accessories

Capillary Tube Gland. Brass Universal Mounting Bracket Capillary Tube Holder
for Bulb Style A / C for Frost Monitors Standard
Part No.: 803 807 Part No.: 803 798 Part No.: 803 778

Mounting Bracket Angle Mounting Plate Extension Bracket


for Units with Hood
Part No.: 803 799 Part No.: 803 801 Part No.: 803 800

Locking Plate

Part No.: 803783 (20 pcs)

259 GPC-EN-2024 CONTROLS COMPONENTS


GPC-EN-2024 CONTROLS COMPONENTS 260
261 GPC-EN-2024 CONTROLS COMPONENTS
System protectors and
Electrical Control Valves
moisture indicators

Filter driers

Basic terminology and technical information

Function Flow capacity


The purpose of filter driers is to keep the refrigeration circuit Flow capacity refers to ARI-Standard 710-86 and DIN 8949
clean of water, acid and solid contaminants. In case of and is based on a pressure drop of 0.07 bar, +30°C liquid
contamination, corrosion and ice building can occur, as well temperature and -15°C evaporating temperature for common
as malfunction of the compressor. refrigerants.

Property of desiccants The flow capacities are given at two levels of pressure drop:
0.07 and 0.14 bar.

Molecular sieves For selection of other operating condition, please use


This kind of desiccant has a very good drying effect Copeland Select software.
independent of the oil content of the refrigerant. Molecular
sieve is a fast acting desiccant and will remove moisture even
when the water content of the refrigerant is low and when the Water capacity
temperature of the liquid refrigerant is high. The water capacity for R22 refers to ARI 710-86 and DIN 8948
is based on a liquid temperature of 24/52°C and an equilibrium
Activated alumina point dryness (EPD) of 60 PPM water in refrigerant. The EPD
for other refrigerants according to DIN 8949 is as follows:
Activated alumina incorporate an excellent acid capacity.
By selecting a specific mixture of both desiccants, an optimum Refrigerant EPD (PPM)
effect can be achieved to cover the requirements of all kinds
of applications. Liquid filter driers are specially designed for a R134a, R407C, R404A, R507C, R410A,
50
R32, R1234ze, R1234yf, R744
high water capacity, whereas suction line filter driers feature a
high acid and filtration capacity. R450A, R513A, R448A, R449A, R452B,
60
R454B, R454C, R454A, R455A

GPC-EN-2024 CONTROLS COMPONENTS 262


Selection table for filter and filter driers
Series
ADKS/FDH with BTAS with
FDS-24 with Core
Selection Criteria Core Core
BFK ADK FDB ASF ASD
H/S/ W48 F48 S24 F24 AF AF-D

Hermetic design + + + + +
For exchangeable cores + + + + + +
Quick cap fange + +
Filter + + + +
Filter drier + + + + + + +
For liquid service + + + + +
For suction service + + + + + + +
For heat pumps (bi-flow) +
Shell material Steel Steel Steel Steel Steel Steel Steel Brass
Max. allowable pressure PS 45 bar 45 bar 45 Bbar 34.5*/46.0* bar 34.5* bar 27.5 bar 24 bar
Note: *) Dependent on Medium Temperature

263 GPC-EN-2024 CONTROLS COMPONENTS


Bi-flow filter driers series BFK hermetic design for liquid refrigerants

Features
• Solid block style
• Integrated check valves ensure Bi-flow capability, eliminate the need
for external check valves and reduce the external piping
• ODF Copper fittings for easy brazing
• Pattern flow for non-turbulent performance
• High water, acid adsorption capacity
• Filtration down to 40 microns
• Temperature range TS: -45°C...+65°C
• Max. allowable pressure PS: 45 bar BFK
• CE marking not required acc. PED
• Underwriter Laboratories

Selection table - A1 refrigerants


Flow Capacity (kW) Pressure Drop 0.07 bar**
Connection
Type Part No. R404A
ODF*/SAE* R134a R407C R410A R450A R513A
R507
BFK 052 007343 1/4”(6 mm) SAE 5.2 5.4 3.7 5.6 4.8 4.6
BFK 052S 007344 1/4” ODF 6.7 7.0 4.8 7.2 6.1 5.9
BFK 083 007345 3/8”(10 mm) SAE 10.6 11.0 7.5 11.4 9.7 9.2
BFK 083S 007346 3/8” ODF 12.0 12.5 8.5 12.9 11.0 10.5
BFK 084 007347 1/2”(12 mm) SAE 15.2 15.8 10.8 16.4 13.9 13.3
BFK 084S 007348 1/2” ODF 15.6 16.2 11.1 16.8 14.3 13.6
BFK 163 007349 3/8”(10 mm) SAE 13.6 14.2 9.7 14.7 12.5 11.9
BFK 163S 007350 3/8” ODF 15.5 16.1 11.0 16.7 14.2 13.5
BFK 164 007351 1/2”(12 mm) SAE 20.3 21.1 14.4 21.9 18.6 17.7
BFK 164S 007352 1/2” ODF 24.3 25.3 17.3 26.1 22.2 21.2
BFK 165 007353 5/8”(16 mm) SAE 25.1 26.2 17.9 27.1 23.0 21.9
BFK 165S 007354 5/8” ODF 25.6 26.7 18.3 27.6 23.5 22.4
BFK 305S 007356 5/8” (16 mm) ODF 34.1 35.6 24.3 36.8 31.3 29.8
BFK 307S 007357 7/8” (22 mm) ODF 40.6 42.3 28.9 43.7 37.2 35.5
BFK 309S 007358 1-1/8” ODF 47.0 49.0 33.5 50.7 43.1 41.1

Selection table - A2L refrigerants


Flow capacity (kW) pressure drop 0.07 bar**
Connection
Type Part No.
ODF*/SAE* R32 R452B R454B R454C R1234ze R1234yf

BFK 052 007343 1/4”(6 mm) SAE 8.1 6.3 6.4 4.2 4.6 3.8
BFK 052S 007344 1/4” ODF 10.4 8.1 8.2 5.4 5.9 4.8
BFK 083 007345 3/8”(10 mm) SAE 16.3 12.8 12.8 8.5 9.2 7.6
BFK 083S 007346 3/8” ODF 18.5 14.5 14.6 9.7 10.5 8.6
BFK 084 007347 1/2”(12 mm) SAE 23.5 18.4 18.5 12.3 13.3 10.9
BFK 084S 007348 1/2” ODF 24.1 18.8 18.9 12.6 13.6 11.2
BFK 163 007349 3/8”(10 mm) SAE 21.1 16.5 16.6 11.0 11.9 9.8
BFK 163S 007350 3/8” ODF 23.9 18.7 18.8 12.5 13.6 11.1
BFK 164 007351 1/2”(12 mm) SAE 31.3 24.5 24.7 16.4 17.8 14.6
BFK 164S 007352 1/2” ODF 37.5 29.3 29.5 19.6 21.3 17.5
BFK 165 007353 5/8”(16 mm) SAE 38.8 30.4 30.6 20.3 22.0 18.1
BFK 165S 007354 5/8” ODF 39.7 31.0 31.2 20.7 22.5 18.5
BFK 305S 007356 5/8” (16 mm) ODF 52.8 41.3 41.5 27.6 29.9 24.6
BFK 307S 007357 7/8” (22 mm) ODF 62.8 49.1 49.4 32.8 35.6 29.2
BFK 309S 007358 1-1/8” ODF 72.7 56.9 57.2 38.0 41.2 33.8
Note 1: Flow capacities are in accordance with ARI710-86 and DIN 8949
Note 2: **) for 0.14 bar pressure drop, multiple values by 1.4
Note 3: *) SAE = Flare ODF = Brazing female
Note 4: Product label update is pending!

GPC-EN-2024 CONTROLS COMPONENTS 264


Nominal operating capacities based on following conditions:
Evaporating Liquid Flow Rate Evaporating Liquid Flow rate
Refrigerant Refrigerant
Temperature Temperature (kg/kW/sec.) Temperature Temperature (kg/kW/sec.)
R134a 0.0068 R32 0.0039
R407C 0.0063 R452B 0.0043
R404A/R507 0.0088 R454B 0.0047
-15°C +30°C -15°C +30°C
R410A 0.0059 R454C 0.0058
R450A 0.0074 R1234ze 0.0076
R513A 0.0079 R1234yf 0.0089
Note: For selection of other operating conditions please use Copeland Select software. Product label update is pending!

Water and acid adsorption capacity


A1 refrigerants
Water Adsorption Capacity (gram) Acid
Liquid Temperature 24°C Liquid Temperature 52°C Adsorption
Type / Size
R404A/ R404A/ Capacity
R134a R407C R410A R450A R513A R134a R407C R410A R450A R513A (gram)
R507 R507
BFK-05... 4.4 4.5 3.4 2.8 6.0 6.0 4.1 4.3 2.8 2.2 5.4 5.4 0.3
BFK-08... 9.6 9.9 7.5 6.2 10.2 10.1 8.9 9.4 6.0 4.7 9.2 9.2 0.6
BFK-16... 18.9 19.5 14.8 12.2 14.1 14.1 17.5 18.5 11.9 9.3 15.5 15.5 1.2
BFK-30... 34.5 35.6 27.1 22.4 28.8 28.8 31.9 33.7 21.7 17.0 31.7 31.7 2.0

A2L refrigerants
Water Adsorption Capacity (gram)
Acid Adsorp-
Liquid Temperature 24°C Liquid Temperature 52°C
Type / Size tion Capac-
R454B/ R452B/ ity (gram)
R32 R452B R1234ze R1234yf R32 R454B R1234ze R1234yf
R454C R454C
BFK-05... 3.4 3.4 3.4 6.0 6.0 2.7 2.6 2.6 5.4 5.4 0.3
BFK-08... 5.7 5.7 5.7 10.2 10.2 4.5 4.4 4.4 9.2 9.2 0.6
BFK-16... 11.5 10.8 10.8 19.1 14.1 9.1 8.3 8.3 17.4 17.4 1.2
BFK-30... 23.2 21.9 21.9 39.1 28.8 18.4 17.0 17.0 35.5 35.5 2.0

Technical data
Max. Allowable Material Shell Steel
45 bar
Pressure PS Paint Epoxy Powder paint
Test Pressure PT 47.3 bar Connections
Copper, ODF
Solder
Burnished, SAE
Liquid Temperature Refrigerant -45…+65 °C Flare
Fluid Group I + II Protection 500+ Hours salt spray test

List of Released Refrigerants Package Individual packaged


Fluid Group II (A1):
R134a, R404A, R407C, R410A, (A2L pending)
R450A, R507, R513A
Fluid Group I (A2L): Marking (acc. PED, V > 1 liter),
R32, R452B, R454B, R454C,
Note: Fluid group classification R1234ze, R1234yf
according to PED 2014/68/EU.

265 GPC-EN-2024 CONTROLS COMPONENTS


Filter driers series ADK hermetic design for liquid refrigerants

Features
• Robust block with optimum blend of molecular
sieve and activated alumina
• ODF Copper fittings for easy brazing
• High water and acid adsorption capacity
• Filtration down to 20 microns
• Temperature range TS: -45°C...+65°C
• Max. allowable pressure PS: 45 bar
• CE marking not required acc. PED
• Underwriter Laboratories ADK

Selection table - A1 refrigerants


Flow capacity (kW) pressure drop 0.07 bar **
Connection
Type Part No. R404A
ODF*/SAE* R134a R407C R410A R448A R449A R450A R513A R452A R744
R507
ADK-032 003595 1/4”(6 mm) SAE 6.7 7.0 4.8 7.2 6.4 6.2 6.1 5.9 4.8 8.1
ADK-032S 003596 1/4” ODF 8.1 8.4 5.7 8.7 7.7 7.5 7.4 7.0 5.8 9.7
ADK-036MMS 003597 6 mm ODF 7.3 7.6 5.2 7.9 7.0 6.8 6.7 6.4 5.3 8.8
ADK-052 003598 1/4”(6 mm) SAE 6.9 7.2 4.9 7.5 6.6 6.5 6.4 6.1 5.0 8.3
ADK-052S 003599 1/4” ODF 9.9 10.3 7.0 10.7 9.4 9.2 9.1 8.6 7.1 11.9
ADK-056MMS 003600 6 mm ODF 9.2 9.5 6.5 9.9 8.7 8.5 8.4 8.0 6.6 11.0
ADK-053 003601 3/8”(10 mm) SAE 13.0 13.5 9.2 14.0 12.3 12.1 11.9 11.3 9.4 15.6
ADK-053S 003602 3/8” ODF 15.0 15.6 10.7 16.1 14.3 14.0 13.7 13.1 10.8 18.0
ADK-0510MMS 003603 10 mm ODF 15.0 15.6 10.7 16.1 14.3 14.0 13.7 13.1 10.8 18.0
ADK-082 003604 1/4”(6 mm) SAE 7.1 7.4 5.1 7.7 6.8 6.7 6.5 6.2 5.2 8.6
ADK-082S 003605 1/4” ODF 10.9 11.4 7.8 11.8 10.4 10.2 10.0 9.6 7.9 13.2
ADK-086MMS 003606 6 mm ODF 9.8 10.2 7.0 10.5 9.3 9.1 9.0 8.5 7.1 11.7
ADK-083 003607 3/8”(10 mm) SAE 15.0 15.6 10.7 16.2 14.3 14.0 13.8 13.1 10.8 18.1
ADK-083S 003608 3/8” ODF 15.0 15.7 10.7 16.2 14.3 14.0 13.8 13.1 10.9 18.1
ADK-0810MMS 003609 10 mm ODF 15.0 15.6 10.7 16.2 14.3 14.0 13.8 13.1 10.8 18.1
ADK-084 003610 1/2”(12 mm) SAE 23.5 24.5 16.7 25.3 22.4 21.9 21.5 20.5 17.0 28.3
ADK-084S 003611 1/2” ODF 24.5 25.6 17.5 26.4 23.3 22.9 22.5 21.4 17.7 29.5
ADK-0812MMS 003612 12 mm ODF 24.1 25.1 17.2 26.0 22.9 22.5 22.1 21.1 17.4 29.0
ADK-162 003613 1/4”(6 mm) SAE 7.3 7.6 5.2 7.8 6.9 6.8 6.7 6.4 5.3 8.8
ADK-163 003614 3/8”(10 mm) SAE 15.4 16.0 10.9 16.5 14.6 14.3 14.1 13.4 11.1 18.5
ADK-163S 003615 3/8” ODF 17.2 17.9 12.2 18.5 16.3 16.0 15.7 15.0 12.4 20.6
ADK-1610MMS 003616 10 mm ODF 17.1 17.8 12.2 18.5 16.3 16.0 15.7 15.0 12.4 20.6
ADK-164 003617 1/2”(12 mm) SAE 28.7 29.9 20.4 30.9 27.3 26.7 26.3 25.1 20.7 34.5
ADK-164S 003618 1/2” ODF 33.0 34.3 23.5 35.5 31.4 30.7 30.2 28.8 23.8 39.6
ADK-1612MMS 003619 12 mm ODF 29.6 30.8 21.1 31.9 28.2 27.6 27.1 25.9 21.4 35.6
ADK-165 003620 5/8”(16 mm) SAE 41.1 42.8 29.2 44.3 39.1 38.3 37.7 35.9 29.7 49.4
ADK-165S 003621 5/8”(16 mm) ODF 45.6 47.4 32.4 49.1 43.3 42.5 41.8 39.8 32.9 54.8
ADK-303 003622 3/8”(10 mm) SAE 16.2 16.9 11.5 17.5 15.4 15.1 14.9 14.2 11.7 19.5
ADK-304 003623 1/2”(12 mm) SAE 28.7 29.9 20.4 30.9 27.3 26.7 26.3 25.1 20.7 34.5
ADK-304S 003624 1/2” ODF 33.0 34.4 23.5 35.6 31.4 30.8 30.3 28.8 23.8 39.7
ADK-305 003626 5/8”(16 mm) SAE 48.2 50.2 34.3 52.0 45.9 45.0 44.2 42.1 34.8 58.0
ADK-305S 003627 5/8”(16 mm) ODF 48.4 50.4 34.4 52.1 46.0 45.1 44.3 42.2 34.9 58.1
ADK-307S 003628 7/8”(22 mm) ODF 60.7 63.2 43.2 65.4 57.8 56.6 55.7 53.0 43.9 73.0
ADK-414 003629 1/2”(12 mm) SAE 33.7 35.1 24.0 36.3 32.1 31.4 30.9 29.4 24.3 40.5
ADK-415 003632 5/8”(16 mm) SAE 53.7 55.9 38.2 57.8 51.1 50.0 49.2 46.9 38.8 64.5
ADK-415S 003633 5/8”(16 mm) ODF 57.7 60.1 41.1 62.2 54.9 53.8 52.9 50.4 41.7 69.4
ADK-417S 003634 7/8”(22 mm) ODF 71.4 74.3 50.8 76.9 67.9 66.6 65.4 62.4 51.5 85.8
ADK-757S 003635 7/8”(22 mm) ODF 96.7 100.7 68.8 104.2 92.0 90.1 88.6 84.4 69.8 116.2
ADK-759S 003636 1-1/8” ODF 107.4 111.8 76.4 115.7 102.1 100.1 98.4 93.8 77.5 129.0
Note 1: Flow capacities are in accordance with ARI710-86 and DIN8949. R744 is not specified by standard.
Note 2: **) for 0.14 bar pressure drop, multiple values by 1.4
Note 3: *) SAE = Flare. ODF = Brazing female
Note 4: Product label update is pending!

GPC-EN-2024 CONTROLS COMPONENTS 266


Nominal flow capacities bases on following operating conditions:
Evaporating Liquid Flow rate Evaporating Liquid Flow rate
Refrigerant Refrigerant
Temperature Temperature (kg/kW/sec.) Temperature Temperature (kg/kW/sec.)
R134a 0.0068 R448A 0.0061
R407C 0.0063 R449A 0.0061
-15°C +30°C
R404A/R507 0.0088 R450A -15°C +30°C 0.0074
R410A 0.0059 R452A 0.0086
R744 -40°C -10°C 0.0039 R513A 0.0079
Note: For selection of other operating conditions please use Copeland Select software.

Selection table - A2L refrigerants


Connection Flow capacity (kW) pressure drop 0.07 bar **
Type Part No.
ODF*/SAE* R32 R452B R454B R454A R454C R455A R1234ze R1234yf
ADK-032 003595 1/4”(6 mm) SAE 10.4 8.1 8.1 6.2 5.4 5.7 5.9 4.8
ADK-032S 003596 1/4” ODF 12.4 9.7 9.8 7.4 6.5 6.9 7.1 5.8
ADK-036MMS 003597 6 mm ODF 11.3 8.9 8.9 6.8 5.9 6.3 6.4 5.3
ADK-052 003598 1/4”(6 mm) SAE 10.7 8.4 8.4 6.4 5.6 5.9 6.1 5.0
ADK-052S 003599 1/4” ODF 15.3 12.0 12.0 9.1 8.0 8.5 8.7 7.1
ADK-056MMS 003600 6 mm ODF 14.2 11.1 11.1 8.5 7.4 7.8 8.0 6.6
ADK-053 003601 3/8”(10 mm) SAE 20.1 15.7 15.8 12.0 10.5 11.1 11.4 9.3
ADK-053S 003602 3/8” ODF 23.2 18.1 18.2 13.8 12.1 12.8 13.1 10.8
ADK-0510MMS 003603 10 mm ODF 23.2 18.1 18.2 13.8 12.1 12.8 13.1 10.8
ADK-082 003604 1/4”(6 mm) SAE 11.0 8.6 8.7 6.6 5.8 6.1 6.2 5.1
ADK-082S 003605 1/4” ODF 16.9 13.2 13.3 10.1 8.8 9.4 9.6 7.9
ADK-086MMS 003606 6 mm ODF 15.1 11.8 11.9 9.0 7.9 8.4 8.6 7.0
ADK-083 003607 3/8”(10 mm) SAE 23.2 18.2 18.3 13.9 12.1 12.8 13.2 10.8
ADK-083S 003608 3/8” ODF 23.2 18.2 18.3 13.9 12.1 12.9 13.2 10.8
ADK-0810MMS 003609 10 mm ODF 23.2 18.2 18.3 13.9 12.1 12.8 13.2 10.8
ADK-084 003610 1/2”(12 mm) SAE 36.3 28.4 28.6 21.7 19.0 20.1 20.6 16.9
ADK-084S 003611 1/2” ODF 37.9 29.7 29.9 22.6 19.8 21.0 21.5 17.7
ADK-0812MMS 003612 12 mm ODF 37.3 29.2 29.3 22.3 19.5 20.6 21.1 17.4
ADK-162 003613 1/4”(6 mm) SAE 11.3 8.8 8.9 6.7 5.9 6.2 6.4 5.2
ADK-163 003614 3/8”(10 mm) SAE 23.7 18.6 18.7 14.2 12.4 13.1 13.4 11.0
ADK-163S 003615 3/8” ODF 26.5 20.7 20.9 15.8 13.8 14.7 15.0 12.3
ADK-1610MMS 003616 10 mm ODF 26.5 20.7 20.8 15.8 13.8 14.7 15.0 12.3
ADK-164 003617 1/2”(12 mm) SAE 44.4 34.7 34.9 26.5 23.2 24.5 25.1 20.6
ADK-164S 003618 1/2” ODF 51.0 39.9 40.1 30.4 26.6 28.2 28.9 23.7
ADK-1612MMS 003619 12 mm ODF 45.8 35.8 36.0 27.3 23.9 25.3 25.9 21.3
ADK-165 003620 5/8”(16 mm) SAE 63.5 49.7 50.0 37.9 33.2 35.1 36.0 29.6
ADK-165S 003621 5/8”(16 mm) ODF 70.4 55.1 55.4 42.0 36.8 39.0 39.9 32.8
ADK-303 003622 3/8”(10 mm) SAE 25.0 19.6 19.7 15.0 13.1 13.9 14.2 11.7
ADK-304 003623 1/2”(12 mm) SAE 44.4 34.7 34.9 26.5 23.2 24.5 25.1 20.6
ADK-304S 003624 1/2” ODF 51.0 39.9 40.1 30.5 26.7 28.2 28.9 23.7
ADK-305 003626 5/8”(16 mm) SAE 74.5 58.3 58.7 44.5 38.9 41.2 42.2 34.7
ADK-305S 003627 5/8”(16 mm) ODF 74.8 58.5 58.8 44.6 39.0 41.4 42.4 34.8
ADK-307S 003628 7/8”(22 mm) ODF 93.9 73.4 73.9 56.0 49.0 51.9 53.2 43.7
ADK-414 003629 1/2”(12 mm) SAE 52.1 40.8 41.0 31.1 27.2 28.8 29.5 24.3
ADK-415 003632 5/8”(16 mm) SAE 83.0 64.9 65.3 49.5 43.3 45.9 47.0 38.6
ADK-415S 003633 5/8”(16 mm) ODF 89.2 69.8 70.2 53.3 46.6 49.4 50.5 41.5
ADK-417S 003634 7/8”(22 mm) ODF 110.4 86.3 86.8 65.9 57.6 61.1 62.5 51.4
ADK-757S 003635 7/8”(22 mm) ODF 149.4 116.9 117.6 89.2 78.1 82.7 84.7 69.5
ADK-759S 003636 1-1/8” ODF 166.0 129.8 130.6 99.1 86.7 91.8 94.0 77.2
Note 1:Flow capacities are in accordance with ARI710-86 and DIN8949.
Note 2: *) SAE = Flare. ODF = Brazing female
Note 3: **) for 0.14 bar pressure drop, multiple values by 1.4
Note 4: Product label update is pending!

Nominal flow capacities bases on following operating conditions:


Evaporating Liquid Flow rate Evaporating Liquid Flow rate
Refrigerant Refrigerant
Temperature Temperature (kg/kW/sec.) Temperature Temperature (kg/kW/sec.)

R32 0.0039 R454C 0.0058


R452B 0.0043 R455A 0.0072
-15°C +30°C -15°C +30°C
R454B 0.0047 R1234ze 0.0076
R454A 0.0061 R1234yf 0.0089
Note: For selection of other operating conditions please use Copeland Select software.

267 GPC-EN-2024 CONTROLS COMPONENTS


Water and acid adsorption capacity

A1 refrigerants / CO2
Water Adsorption Capacity (gram)
Acid
Liquid Temperature 24°C Liquid Temperature 52°C Adsorption
Type / Size
Capacity
R404A/ R404A/ (gram)
R134a R407C R410A R744 R134a R407C R410A R744
R507 R507
ADK-03 4.9 4.9 3.4 2.8 4.6 4.4 4.6 2.9 2.4 4.2 0.8
ADK-05 11.8 11.8 8.2 6.8 8.7 10.6 10.9 7 5.8 7.9 2.3
ADK-08 17.9 18.0 12.4 10.3 13.2 16.2 16.6 10.7 8.8 12.0 3.3
ADK-16 23.0 23.1 16.0 13.2 17.0 20.8 21.3 13.8 11.4 15.4 4.5
ADK-30 51.8 53.5 36.9 30.6 41.0 47.4 49.3 31.8 26.3 38.1 11.3
ADK-41 81.7 84.3 58.2 48.3 54.3 74.8 77.8 50.2 41.4 50.5 16.8
ADK-75 143.5 148.1 102.1 84.8 96.3 131.4 136.6 88.1 72.8 89.5 29.9

Water Adsorption Capacity (gram)


Acid
Liquid Temperature 25°C Liquid Temperature 52°C Adsorption
Type / Size
Capacity
R448A R449A R450A R513A R452A R448A R449A R450A R513A R452A (gram)

ADK-03 4.7 4.7 6.0 6.0 3.4 4.3 4.3 5.5 5.4 2.7 0.8
ADK-05 9.0 9.0 11.4 11.3 6.5 8.2 8.2 10.3 10.3 5.0 2.3
ADK-08 13.7 13.7 17.3 17.2 9.8 12.4 12.4 15.7 15.7 7.7 3.3
ADK-16 17.5 17.5 22.2 22.1 12.6 16.0 16.0 20.2 20.1 9.9 4.5
ADK-30 39.9 39.9 52.0 51.7 32.8 37.5 36.3 46.1 45.9 25.6 11.3
ADK-41 52.8 52.8 68.8 68.4 43.4 49.7 48.1 61.0 60.7 33.9 16.8
ADK-75 93.8 93.8 122.1 121.4 77.1 88.2 85.3 108.4 107.8 60.1 29.9

A2L refrigerants
Water Adsorption Capacity (gram)
Acid
Liquid Temperature 24°C Liquid Temperature 52°C Adsorption
Type / Size
R454A R454A Capacity
R1234ze R1234ze (gram)
R32 R452B R454B R455A R32 R452B R454B R455A
R1234yf R1234yf
R454C R454C
ADK-03 3.4 3.4 3.4 3.4 6.0 2.7 2.7 2.7 2.7 5.5 0.8
ADK-05 6.5 6.5 6.5 6.5 11.4 5.2 5.0 5.0 5.0 10.3 2.3
ADK-08 9.8 9.8 9.8 9.8 17.3 7.8 7.7 7.7 7.7 15.7 3.3
ADK-16 12.6 12.6 12.6 12.6 22.2 10.1 9.9 9.9 9.9 20.2 4.5
ADK-30 32.8 32.8 32.8 32.8 57.6 26.2 25.6 25.6 25.6 52.5 11.3

ADK-41 43.4 43.4 43.4 43.4 76.2 34.6 33.9 33.9 33.9 69.4 16.8
ADK-75 77.1 77.1 77.1 77.1 135.4 61.5 60.1 60.1 60.1 123.3 29.9

Technical data
Max. allowable pressure PS 45 bar Material shell Steel

Test pressure PT 47.3 bar Paint Epoxy powder paint

-45…+65°C Connections
Liquid temperature refrigerant
Solder Copper, ODF
Fluid group I + II Flare Burnished, SAE
Protection
List of released refrigerants 500+ hours salt spray test
Fluid group II (A1): R134a, R404A, R407C, R410A,
R448A, R449A, R450A, R452A, Package Individual packaged
R507, R513A, R744
Fluid group I (A2L): R32, R452B, R454B, R454A,
Marking (A2L pending)
R454C, R455A, R1234ze, R1234yf
Note: Fluid group classification (acc. PED, V > 1 liter)
according to PED 2014/68/EU.

GPC-EN-2024 CONTROLS COMPONENTS 268


Filter driers series FDB hermetic design, bead style for liquid refrigerants

Features
• Compacted bead style (spring loaded)
• Optimum blend of molecular sieve and activated alumina
combined with high filtration capacity
• Filtration first for more effective use of surface area of
desiccant
• High water and acid capacity
• Cushioned flow for non-turbulent performance
• ODF Copper fittings for easy brazing
• Rugged steel shells
• Corrosion-resistant epoxy paint
FDB
• Temperature range TS: -40°C...+65°C
• Max. allowable pressure PS: 45 bar
• CE marking not required acc. PED
• Underwriter Laboratories

Selection table - A1 refrigerants


Flow capacity (kW) pressure drop 0.07 bar **
Connection
Type Part No. R404A
ODF*/SAE* R134a R407C R410A R448A R449A R450A R452A R513A
R507
FDB-032 059305 1/4”(6 mm) SAE 6.3 6.6 4.5 6.8 6.0 5.9 5.8 4.6 5.5
FDB-032S 059306 1/4” ODF 9.7 10.1 6.9 10.5 9.2 9.1 8.9 7.0 8.5
FDB-052 059307 1/4”(6 mm) SAE 6.5 6.8 4.6 7.0 6.2 6.1 6.0 4.7 5.7
FDB-052S 059309 1/4” ODF 9.7 10.1 6.9 10.5 9.2 9.1 8.9 7.0 8.5
FDB-053 059308 3/8”(10 mm) SAE 15.5 16.1 11.0 16.7 6.4 6.3 6.2 4.9 5.9
FDB-053S 059310 3/8” ODF 19.3 20.1 13.8 20.8 9.4 9.2 9.1 7.1 8.6
FDB-082 059311 1/4”(6 mm) SAE 6.8 7.1 4.8 7.3 6.4 6.3 6.2 4.9 5.9
FDB-082S 059314 1/4” ODF 9.9 10.3 7.0 10.7 14.7 14.4 14.2 11.2 13.5
FDB-083 059312 3/8”(10 mm) SAE 15.8 16.4 11.2 17.0 18.4 18.0 17.7 14.0 16.9
FDB-083S 059315 3/8” ODF 19.8 20.6 14.1 21.3 15.0 14.7 14.4 11.4 13.8
FDB-084 059313 1/2”(12 mm) SAE 26.4 27.5 18.8 28.4 18.8 18.4 18.1 14.3 17.3
FDB-084S 059316 1/2” ODF 28.3 29.5 20.1 30.5 15.4 15.1 14.9 11.7 14.2
FDB-162 059317 1/4”(6 mm) SAE 6.8 7.1 4.8 7.3 21.9 21.4 21.1 16.6 20.1
FDB-163 059318 3/8”(10 mm) SAE 16.2 16.9 11.5 17.5 17.2 16.8 16.5 13.0 15.8
FDB-163S 059321 3/8” ODF 23.0 23.9 16.4 24.8 25.1 24.6 24.2 19.0 23.0
FDB-164 059319 1/2”(12 mm) SAE 27.9 29.1 19.9 30.1 26.9 26.4 25.9 20.4 24.7
FDB-164S 059322 1/2” ODF 36.0 37.5 25.6 38.8 26.6 26.0 25.6 20.2 24.4
FDB-165 059320 5/8”(16 mm) SAE 36.6 38.2 26.1 39.5 34.2 33.6 33.0 26.0 31.4
FDB-165S 059323 5/8” ODF 48.8 50.8 34.8 52.6 30.2 29.6 29.1 23.0 27.8
FDB-303 059324 3/8”(10 mm) SAE 18.0 18.8 12.8 19.4 36.2 35.4 34.8 27.4 33.2
FDB-304 059325 1/2”(12 mm) SAE 31.8 33.1 22.6 34.2 34.9 34.2 33.6 26.5 32.0
FDB-304S 003667 1/2” ODF 38.0 39.6 27.1 41.0 46.4 45.5 44.7 35.3 42.6
FDB-305 059326 5/8”(16 mm) SAE 40.3 42.0 28.7 43.4 38.3 37.6 36.9 29.1 35.2
FDB-305S 059327 5/8” ODF 53.8 56.0 38.3 57.9 51.2 50.1 49.3 38.8 47.0
FDB-307S 059328 7/8” ODF 60.5 63.1 43.1 65.2 47.3 46.4 45.6 35.9 43.4
FDB-415 059329 5/8”(16 mm) SAE 49.7 51.8 35.4 53.6 57.6 56.5 55.5 43.7 52.9
FDB-417S 059330 7/8” ODF 77.2 80.4 55.0 83.2 73.5 72.0 70.8 55.8 67.5
Note 1: Flow capacities are in accordance with ARI710-86 and DIN8949.
Note 2: **) for 0.14 bar pressure drop, multiple values by 1.4
Note 3: *) SAE = Flare. ODF = Brazing female
Note 4: Product label update is pending!

269 GPC-EN-2024 CONTROLS COMPONENTS


Nominal flow capacities bases on following operating conditions:
Evaporating Liquid Flow rate Evaporating Liquid Flow rate
Refrigerant Refrigerant
Temperature Temperature (kg/kW/sec) Temperature Temperature (kg/kW/sec)
R134a 0.0068 R448A 0.0061
R407C 0.0063 R449A 0.0061
-15°C +30°C -15°C +30°C
R404A/R50 0.0088 R450A 0.0074
R410A 0.0059 R452A 0.0086
Note: For selection of other operating conditions please use Copeland Select software.

Selection table - A2L refrigerants


Flow capacity (kW) pressure drop 0.07 bar **
Connection
Type Part No.
ODF*/SAE* R32 R452B R454B R454A R454C R455A R1234ze R1234yf

FDB-032 059305 1/4”(6 mm) SAE 9.8 7.6 7.7 5.8 5.1 5.4 4.5 5.5
FDB-032S 059306 1/4” ODF 15.0 11.7 11.8 9.0 7.8 8.3 7.0 8.5
FDB-052 059307 1/4”(6 mm) SAE 10.1 7.9 7.9 6.0 5.3 5.6 4.7 5.7
FDB-052S 059309 1/4” ODF 15.0 11.7 11.8 9.0 7.8 8.3 7.0 8.5
FDB-053 059308 3/8”(10 mm) SAE 23.9 18.7 18.8 14.3 12.5 13.2 11.1 13.6
FDB-053S 059310 3/8” ODF 29.9 23.4 23.5 17.8 15.6 16.5 13.9 16.9
FDB-082 059311 1/4”(6 mm) SAE 10.5 8.2 8.2 6.3 5.5 8.5 4.9 5.9
FDB-082S 059314 1/4” ODF 15.3 12.0 12.0 9.1 8.0 5.8 7.1 8.7
FDB-083 059312 3/8”(10 mm) SAE 24.4 19.1 19.2 14.5 12.7 13.5 11.3 13.8
FDB-083S 059315 3/8” ODF 30.6 23.9 24.1 18.3 16.0 16.9 14.2 17.3
FDB-084 059313 1/2”(12 mm) SAE 40.8 31.9 32.1 24.3 21.3 22.6 19.0 23.1
FDB-084S 059316 1/2” ODF 43.8 34.2 34.4 26.1 22.9 24.2 20.4 24.8
FDB-162 059317 1/4”(6 mm) SAE 10.5 8.2 8.2 6.3 5.5 5.8 4.9 5.9
FDB-163 059318 3/8”(10 mm) SAE 25.1 19.6 19.7 15.0 13.1 13.9 11.7 14.2
FDB-163S 059321 3/8” ODF 35.5 27.8 28.0 21.2 18.6 19.7 16.5 20.1
FDB-164 059319 1/2”(12 mm) SAE 43.2 33.8 34.0 25.8 22.6 23.9 20.1 24.5
FDB-164S 059322 1/2” ODF 55.7 43.5 43.8 33.2 29.1 30.8 25.9 31.5
FDB-165 059320 5/8”(16 mm) SAE 56.6 44.3 44.6 33.8 29.6 31.3 26.4 32.1
FDB-165S 059323 5/8” ODF 75.5 59.0 59.4 45.1 39.4 41.8 35.1 42.8
FDB-303 059324 3/8”(10 mm) SAE 27.9 21.8 21.9 16.7 14.6 15.4 13.0 15.8
FDB-304 059325 1/2”(12 mm) SAE 49.1 38.4 38.7 29.3 25.7 27.2 22.9 27.8
FDB-304S 003667 1/2” ODF 58.8 46.0 46.2 35.1 30.7 32.5 27.3 33.3
FDB-305 059326 5/8”(16 mm) SAE 62.3 48.7 49.0 37.2 32.5 34.5 29.0 35.3
FDB-305S 059327 5/8” ODF 83.1 65.0 65.4 49.6 43.4 46.0 38.7 47.1
FDB-307S 059328 7/8” ODF 93.6 73.2 73.6 55.9 48.9 51.8 43.6 53.0
FDB-415 059329 5/8”(16 mm) SAE 76.9 60.1 60.5 45.9 40.2 51.8 35.8 43.6
FDB-417S 059330 7/8” ODF 119.4 93.4 93.9 71.3 62.3 66.0 55.6 67.6
Note 1:Flow capacities are in accordance with ARI710-86 and DIN8949.
Note 2: *) SAE = Flare. ODF = Brazing female
Note 3: **) for 0.14 bar pressure drop, multiple values by 1.4
Note 4: Product label update is pending!

Nominal flow capacities bases on following operating conditions:


Evaporating Liquid Flow rate Evaporating Liquid Flow rate
Refrigerant Refrigerant
Temperature Temperature (kg/kW/sec) Temperature Temperature (kg/kW/sec)
R32 0.0039 R454C 0.0058
R452B 0.0043 R455A 0.0072
-15°C +30°C -15°C +30°C
R454B 0.0047 R1234ze 0.0076
R454A 0.0061 R1234yf 0.0089
Note: For selection of other operating conditions please use Copeland Select software.

GPC-EN-2024 CONTROLS COMPONENTS 270


Water and acid adsorption capacity

A1 refrigerants
Water Adsorption Capacity (gram)
Liquid Temperature 24°C Liquid Temperature 52°C
Type / Size
R134a R404A/R507 R407C R410A R452A R134a R404A/R507 R407C R410A R452A

FDB-03... 1.9 1.9 1.7 1.6 1.8 1.9 1.6 1.3


FDB-05... 5.5 5.5 5.0 4.4 5.2 5.3 4.5 3.3
FDB-08... 8.8 8.8 8.0 7.1 8.4 8.5 7.2 5.4
FDB-16... 17.7 17.6 15.9 14.2 16.8 17.1 14.5 10.8
FDB-30... 31.7 31.6 28.5 25.0 30.1 30.5 26.0 19.0
FDB-41... 44.2 44.1 39.9 35.0 42.1 42.7 36.3 26.6

Water Adsorption Capacity (gram)


Type / Size Liquid Temperature 25°C Liquid Temperature 52°C
R448A R449A R450A R513A R448A R449A R450A R513A
FDB-03... 2.5 2.5 2.5 2.5 2.3 2.3 2.3 2.3
FDB-05... 6.8 6.8 6.9 6.9 6.2 6.2 6.3 6.3
FDB-08... 10.9 10.9 11.1 11.1 9.9 9.9 10.1 10.1
FDB-16... 21.6 21.6 22.0 22.0 19.7 19.7 20.0 20.0
FDB-30... 37.9 37.9 38.6 38.6 34.6 34.6 35.2 35.2
FDB-41... 53.2 53.2 54.2 54.2 48.5 48.5 49.4 49.4

A2L refrigerants
Water Adsorption Capacity (gram)
Liquid Temperature 24°C Liquid Temperature 52°C
Type / Size R454A R454A
R1234ze R1234ze
R32 R452B R454B R455A R32 R452B R454B R455A
R1234yf R1234yf
R454C R454C
FDB-03... 2.3 2.4 2.4 2.4 2.5 2.2 2.0 2.0 2.0 2.3
FDB-05... 6.3 6.5 6.5 6.5 6.9 5.9 5.5 5.5 5.5 6.3
FDB-08... 10.1 10.4 10.4 10.4 11.1 9.5 8.8 8.8 8.8 10.1
FDB-16... 20.1 20.7 20.7 20.7 22.0 18.8 17.5 17.5 17.5 20.0
FDB-30... 35.3 36.3 36.3 36.3 38.6 33.1 30.8 30.8 30.8 35.2
FDB-41... 49.5 50.9 50.9 50.9 54.2 46.4 43.2 43.2 43.2 49.4

Technical data
Max. Allowable Pressure PS 45 bar Material shell Steel

Test pressure PT 47.3 bar Paint Epoxy Powder paint


Connections
Liquid temperature refrigerant -45…+65°C
Solder Copper, ODF
Fluid Group I + II Flare Burnished, SAE
Protection
List of released refrigerants 500+ Hours salt spray test
Fluid group II (A1): R134a, R404A, R407C, R410A,
R448A, R449A, R450A, R452A, Package Individual packaged
R507, R513A

Fluid group I (A2L): R32, R452B, R454B, R454A,


R454C, R455A, R1234ze, R1234yf Marking (A2L pending)
Note: Fluid group classification
according to PED 2014/68/EU. (acc. PED, V > 1 liter)

271 GPC-EN-2024 CONTROLS COMPONENTS


Filter drier shells series ADKS-plus for liquid - and
suction applications with replaceable cores

Features
• Rustproof Aluminum flange cover with notch hole for
ease of mounting
• ODF Copper fittings for easy brazing
• Rigid core holder from steel (no plastic)
• Service-friendly core holder and flange cover
• Optimum flow capacity at low pressure drop
• Temperature range TS: -45°C...+65°C
• Max. allowable pressure PS:
34.5 bar (-10°C...+65°C)
25.9 bar (-45°C...-10°C) ADKS-Plus
• according PED CE0036
(Cat.II/Mod.D1 acc. to PED, V>1l)
• Underwriter Laboratories

Selection table

Number of Blocks
Connection Nominal Flow Capacity (kW)
Solder/ODF

W48, F48
S48, H48
Pressure Drop 0.07 bar
Type Part No.

R1234ze
R404A/

R407C

R410A

R448A

R449A

R450A

R513A
R134a
(inch)

R507
(mm)

R22

Conformity Assessment Cat. I, Procedure Module A


485T 883551 16 5/8 78 72 51 75 77 68 67 66 63 63
487T 883552 22 7/8 145 133 95 138 143 126 124 122 116 116
489T 883553 1-1/8 204 187 133 195 202 178 174 172 163 164
1
4811T 883554 35 1-3/8 285 261 186 272 281 248 243 239 228 228
4813T MM 883836 42 310 284 202 196 306 270 265 260 248 249
4817 882603 54 2-1/8 Primary for Suction Line Applications
967T 883555 22 7/8 159 146 104 152 157 139 136 134 127 128
969T 883556 1-1/8 250 229 163 239 247 218 214 210 200 201
9611T 883557 35 1-3/8 305 279 199 291 301 266 260 256 244 245
2
9613T 883558 1-5/8 350 321 228 334 345 305 299 294 280 281
9613T MM 883559 42 355 325 231 339 350 309 303 298 284 285
9617 887215 54 2-1/8 350 321 228 334 345 305 299 294 280 281
1449T 883560 1-1/8 252 231 165 241 249 220 216 212 202 202
14411T 883561 35 1-3/8 351 322 229 335 347 306 300 295 281 282
14413T 883562 1-5/8 354 325 231 338 350 309 303 298 284 284 3
14413T MM 883563 42 360 330 235 343 355 314 307 302 288 289
14417T 883564 54 2-1/8 420 385 274 401 415 366 359 353 336 337
Conformity Assessment Cat. II, Procedure Module D1
19211T 883565 35 1-3/8 358 328 233 342 353 312 306 301 287 287
19213T 883566 1-5/8 395 362 258 377 390 344 337 332 316 317
4
19213T MM 883567 42 400 366 261 382 395 349 342 336 320 321
19217T 883568 54 2-1/8 430 394 281 411 425 375 368 361 344 345

Nominal capacity (Qn) is based on the following conditions:


Refrigerant Evaporating Temperature Liquid Temperature

R744 -40°C -10°C

R22, R134a, R404A, R407C, R410A, R450A,


-15°C +30°C
R507, R513A, R1234ze, R448A, R449A

GPC-EN-2024 CONTROLS COMPONENTS 272


Filter drier shells series FDH for
liquid- and suction applications with replaceable cores
Features
• Steel flange cover with notch hole for ease of mounting
• Plated steel ODF connections
• Rigid core holder from steel (no plastic)
• Service-friendly core holder and flange cover
• Optimum flow capacity at low pressure drop
• Temperature range TS: -45°C...+65°C
• Max. allowable pressure PS:
46 bar (-10°C...+65°C)
25.9 bar (-45°C...-10°C)
FDH
• according PED
CE 0036(Cat.II/Mod.D1) (acc. to PED, V>1l)

Selection table
Connection Nominal Flow Capacity (kW)

Number of
Solder/ODF Pressure Drop 0.07 bar Pressure Drop 0.14bar

Blocks
Type Part No.
R407C

R407C
R404A

R410A

R410A
R134a

R134a
R507

R744

R404
R507

R744
R22

R22
(mm) (inch)

Conformity Assessment Cat. I, Procedure Module A


FDH-485 880300 16 5/8” 78 72 51 75 77 114 100 92 65 95 99 146
FDH-487 880301 22 7/8” 145 133 95 138 143 211 182 167 119 174 180 265 1
FDH-489 880302 1-1/8” 204 187 133 195 202 297 262 240 171 250 258 380
FDH-969 880306 1-1/8” 250 229 163 239 247 364 300 275 196 286 296 436
2
FDH-9611 880307 35 1-3/8” 305 279 199 291 301 443 402 369 262 384 397 585
Note: Conditions for nominal capacities see previous page. For selection of other operating condition, please use Copeland Select software.

Features core
• Water capacities to suit specific system conditions
• Exceptional acid capacities for normal system protection, or to
effectively clean-up following a compressor burnout (W48)

Core H48

Selection table - core for ADKS-plus & FDH (to be ordered separately)
Water Adsorption Capacity (g) Acid
Liquid Temperature 24°C Liquid Temperature 52°C Adsorption
Size Part No.
R404A R404A Capacity
R134a R22 R407C R134a R22 R407C (g)
R507 R507
S48 003508 79.7 74.7 82.3 56.7 73.0 66.7 75.9 48.9 16.3
H48 006969 35.0 31.7 37.0 24.4 29.0 24.5 28.9 18.1 44.6
W48 006970 24.7 22.1 26.2 17.1 19.9 16.4 19.5 12.1 39.7
F48 006973 Filter For Suction Line
H100 / W100 are for Use with Phased-out ADKS-300/-400 Only
H100 006971 59.9 53.3 63.8 41.2 47.4 38.3 46.0 28.5 105.1
W100 006972 52.7 47.1 56.0 36.4 42.4 34.7 41.4 25.7 85.5

Accessories and spare parts for ADKS & FDH


Description Type Part No.
ADKS, FDH
Gasket Set X 99961 003710
Schrader Nipple 1/4” NPT X 11562-2 803251
Core Holder X 99963 003712

273 GPC-EN-2024 CONTROLS COMPONENTS


Filter-drier shells with quick-cap series FDS-24 for
liquid and suction applications with replaceable cores

Features
• Quick-cap flange (one bolt) design makes replacing of
cores in a matter of seconds
• Ideal for retrofit, reducing installation / material cost
• Ideal for refrigerant recovery / reclaim units with regular
change of filter-drier
• Free volume as a receiver in FDS-24... (580 cm3)
• ODF Copper fittings for easy brazing FDS-24
• Corrosion-resistant powder painting of shell body
• Temperature range TS: -45°C...+65°C
• Max. allowable pressure PS:
34.5 bar (-10°C...+65°C)
25.9 bar (-45°C...-10°C)
• (Cat.I, Mod.A)

• Listed

Selection table suction application


Connection Nominal Flow Capacity (kW)
Block Core S24 Filter F24
(inch)

Type Part No.


(mm)

R507 R507
R134a R22 R407C R448A R449A R450A R513A R1234ze R134a R22 R407C
R404A R404A
FDS-245 003573 16 5
/8 22.3 30.6 28.5 26.0 65.1 63.8 62.7 59.8 59.9 24.7 33.9 31.5 28.8
FDS-247 003574 22 7
/8 32.2 44.1 44.1 37.5 97.4 95.4 93.8 89.4 89.7 37.8 51.8 48.2 44.0
FDS-249 003575 1 1/8 46.0 63.0 58.6 53.6 98.5 96.5 94.9 90.4 90.7 50.7 69.4 64.5 59.0
FDS-249 003576 28 44.2 60.5 56.3 51.4 99.0 97.0 95.3 90.9 91.1 48.6 66.9 61.9 56.6

Selection table liquid application


Connection Nominal Flow Capacity (kW)
Solder/ODF Pressure Drop 0.07 bar Pressure Drop 0.14 bar
Type Part No.
R507/ R507/
(mm) (inch) R22 R134a R407C R410A R22 R134a R407C R410A
R404A R404A
FDS-245 003573 16 5/8 75 68 49 71 74 98 90 64 93 97
FDS-247 003574 22 7/8 112 102 73 107 110 151 139 99 144 149
FDS-249 003575 1-1/8 113 104 74 108 112 160 147 104 153 158
FDS-249 003576 28 114 104 74 108 112 163 150 106 156 161

Note: For selection of other operating condition, please use Copeland Select software.

Selection table cores


Water Capacity in Grams at a Liquid Temperature of 24°C (52°C) Acid Adsorption
Type Part No. Application
R134a R22 R404A/R507 Capacity (g)
S24 003504 35.2 (32.3) 34.8 (29.5) 35.4 (32.1) Liquid and Suction Line 8.9
W24 003505 12.5 (9.2) 12.3 (8.9) 13.5 (10.4) For Motor Burn-Out (Suction) 25.6
F24 003506 - (-) - (-) - (-) Filter for Suction Line -
Note: Cores have to be ordered separately. 1 piece needed for FDS24 shell.

Accessories and spare parts for FDS


Description Type Part No.
Gasket Set X 99967 003716
O-Ring Set X 99968 003717
Core Holder X 99969 003718

GPC-EN-2024 CONTROLS COMPONENTS 274


Suction line filters and filter driers series ASF and ASD hermetic design

Features
• Minimum pressure drop due to internal construction and compacted bead style
• Service-friendly with 2 Schrader valves for pressure drop measurement
• ODF Copper fittings for easy brazing
• Filtration down to 40 microns
• Temperature range TS: -45°C...+50°C
• Max. allowable pressure PS: 27.5 bar
ASF, ASD
• marking not required acc. PED

Suction line filters


Connection
Nominal Flow Capacity (kW)
Solder/ODF
Type Part No.
R448A
(mm) (inch) R134a R22 R404A R407C R507 R450A R513A R1234ze
R449A
ASF-28 S3 008965 3/8 6.0 8.4 7.7 7.8 7.7 8.6 4.1 3.7 3.5
ASF-28 S4 008941 1/2 9.9 14.4 13.4 13.4 13.4 14.8 6.8 6.2 5.8
ASF-35 S5 008915 16 5/8 15.9 23.2 21.4 21.6 21.4 23.7 11.2 10.2 9.6
ASF-45 S6 008946 3/4 23.3 34.5 32.0 32.1 32.0 35.3 16.3 14.8 14.0
ASF-45 S7 008904 22 7/8 32.5 42.5 34.5 39.5 34.5 43.2 22.8 20.7 19.6
ASF-50 S9 008908 1-1/8 46.0 67.1 55.5 62.4 55.5 68.4 32.3 29.3 27.8
ASF-75 S11 008919 35 1-3/8 60.2 85.4 70.7 79.4 70.7 57.6 40.8 37.0 35.1
ASF-75 S13 008940 1-5/8 65.4 87.5 73.1 81.4 73.1 86.4 47.6 43.2 40.9

Suction line filter driers


Connection
Nominal Flow Capacity (kW)
Solder/ODF
Type Part No.
R448A
(mm) (inch) R134a R22 R404A R407C R507 R450A R513A R1234ze
R449A
ASD-28 S3 008909 3/8 5.5 8.1 7.4 7.5 7.4 8.3 3.7 3.4 3.2
ASD-28 S4 008910 1/2 9.1 13.4 12.7 12.5 12.7 13.7 6.5 5.9 5.6
ASD-35 S5 008899 16 5/8 14.3 20.4 19.0 19.0 19.0 20.9 9.9 8.9 8.5
ASD-45 S6 008925 3/4 19.1 24.6 22.5 22.9 22.5 25.2 13.3 12.0 11.4
ASD-45 S7 008896 22 7/8 25.0 32.3 26.4 30.0 26.4 33.1 17.3 15.7 14.9
ASD-50 S9 008881 1-1/8 35.3 46.4 38.3 43.2 38.3 47.5 24.8 22.5 21.3
ASD-75 S11 008891 35 1-3/8 42.9 56.9 47.8 52.9 47.8 58.3 29.9 27.1 25.7
ASD-75 S13 008953 1-5/8 45.2 60.8 51.0 56.5 51.0 62.2 31.6 28.7 27.2

Nominal flow capacity at +4°C evaporating temperature (saturated condition/


dew point) and a pressure drop of 0.21 bar between inlet and outlet of ASF/ASD. Qn: Nominal Capacity
Correction factor for other evaporating temperatures than +4°C: Ks: Correction Factor for a Pressure Drop Corresponding 1 K
Qn = Qo x Ks Saturation Temperature
Qo: Required Cooling Capacity
For selection of other operating condition, please use Copeland
Select software.

Evaporating Temperature (°C) +4 0 -5 -10 -15 -20 -25 -30 -35 -40
Correction Factor kt 1.00 1.12 1.35 1.75 2.00 2.50 3.00 3.75 5.00 6.60

Water and acid adsorption capacity


Water Adsorption Capacity (g)
Acid
Liquid Temperature 24°C Liquid Temperature 52°C
Type Adsorption
R404A R404A Capacity (g)
R134a R22 R407C R410A R134a R22 R407C R410A
R507 R507
ASD-28 11.8 5.7 12.2 9.1 8.0 10.0 3.6 9.7 6.7 5.6 3.0
ASD-35 14.5 7.0 15.0 11.2 9.9 12.3 4.4 12.0 8.2 6.9 3.6
ASD-45 18.0 8.8 18.6 13.9 12.3 15.3 5.5 14.9 10.2 8.6 4.5
ASD-50 21.4 10.4 22.2 16.5 14.6 18.2 6.5 17.7 12.1 10.2 5.4
ASD-75 31.5 15.4 32.6 24.3 21.5 26.7 9.6 26.0 17.8 15.0 7.9

275 GPC-EN-2024 CONTROLS COMPONENTS


Suction line filter and filter drier shells series BTAS for
replaceable filters and filter drier cores

Features
• Corrosion-free brass body ideal for suction line
applications
• Extremely large filtration area for optimum flow capacity
• Low pressure drop
• Filtration down to 40 micron
BTAS
• Temperature range TS: -45°C ... +50°C
• Max. allowable pressure PS: 24 bar
• UL/CUL: File Nr. SA3124

Selection table - suction line shells with filter core


Connection Nominal Capacity Qn
Filter Core
Solder/ODF (kW)
Type Part No.
R448A
(mm) (inch) R134a R22 R404A R407C R507 R450A R513A R1234ze Type Part No.
R449A
CE marking not required acc. PED
BTAS 25 015353 5/8 12.5 17.1 13.9 15.9 13.9 18.2 9.4 8.5 8.4
A2F 009 907
BTAS 27 015354 22 7/8 22.3 29.6 24.3 27.5 24.3 31.7 16.3 14.8 14.6
BTAS 39 015355 1 1/8 37.7 50.4 40.6 46.9 40.6 50.4 24.8 22.5 22.2
BTAS 311 015356 35 1 3/8 60.3 80.7 65.2 75.1 65.2 54.0 27.5 25.0 24.7
BTAS 313 015357 1 5/8 73.4 97.5 81.1 90.7 81.1 86.4 44.2 40.1 39.6 A3F 009 909
BTAS 342 015358 42 73.4 97.5 81.1 90.7 81.1 86.4 44.2 40.1 39.6
BTAS 317 015359 54 2 1/8 97.6 127.7 104.8 118.8 104.8 104.3 54.4 49.3 48.7
BTAS 417 015360 54 2 1/8 134.7 178.2 145.3 165.7 145.3 190.7 98.6 89.4 88.3 A4F 009 911
CE Marked, Conformity Assessment Cat. I, Procedure Module A
BTAS 521 015361 2 5/8 209.0 282.4 229.8 262.6 229.8 302.2 153.0 138.7 137.0
BTAS 525 015362 3 1/8 260.1 346.1 283.9 321.9 283.9 370.6 190.4 172.6 170.4 A5F 009 913
BTAS 580 015363 80 260.1 346.1 283.9 321.9 283.9 370.6 190.4 172.6 170.4
Note: Filter Core has to be ordered separately.

Selection table - suction line shells with filter drier core


Connection Nominal Capacity Qn
Filter Drier Core
Solder/ODF (kW)
Type Part No.
R448A
(mm) (inch) R134a R22 R404A R407C R507 R450A R513A R1234ze Type Part No.
R449A
CE marking not required acc. PED
BTAS 25 015353 5/8 11.6 15.5 12.8 14.3 12.8 16.6 8.5 7.7 7.6
A2F-D 009 908
BTAS 27 015354 22 7/8 19.1 25.2 20.6 23.4 20.6 27.0 13.9 12.6 12.5
BTAS 39 015355 1 1/8 34.4 45.7 37.5 42.5 37.5 36.0 18.0 16.3 16.1
BTAS 311 015356 35 1 3/8 49.2 65.5 53.7 60.9 53.7 50.4 25.2 22.8 22.5
BTAS 313 015357 1 5/8 57.1 77.3 62.5 71.9 62.5 72.0 37.4 33.9 33.5 A3F-D 009 910
BTAS 342 015358 42 57.1 77.3 62.5 71.9 62.5 72.0 37.4 33.9 33.5
BTAS 317 015359 54 2 1/8 77.1 94.1 77.7 87.5 77.7 82.8 40.8 37.0 36.5
BTAS 417 015360 54 2 1/8 106.8 144.5 118.3 134.4 118.3 154.7 78.2 70.9 70.0 A4F-D 009 912
CE marked, Conformity Assessment Cat. I, Procedure Module A
BTAS 521 015361 2 5/8 153.3 205.1 169.0 190.7 169.0 219.5 112.2 101.7 100.4
BTAS 525 015362 3 1/8 181.2 242.0 199.4 225.1 199.4 259.1 132.6 120.2 118.7 A5F-D 009 914
BTAS 580 015363 80 181.2 242.0 199.4 225.1 199.4 259.1 132.6 120.2 118.7
Note: Filter drier core has to be ordered separately.

GPC-EN-2024 CONTROLS COMPONENTS 276


Nominal capacity at +4°C evaporating temperature (saturated condition/ Qn: Nominal capacity
dew point) and a pressure drop of 0.21 bar between inlet and outlet of Ks: Correction factor for a pressure drop corresponding 1K saturation
BTAS. Correction factor for other evaporating temperatures than +4°C: temperature
Qn = Qo x Ks Qo: Required cooling capacity

Evaporating Temperature (°C) +4 0 -5 -10 -15 -20 -25 -30 -35 -40
Correction Factor kt 1.00 1.12 1.35 1.75 2.00 2.50 3.00 3.75 5.00 6.60

BTAS - water and acid adsorption capacity


Water Adsorption Capacity (g)
Acid
Liquid Temperature 24°C Liquid Temperature 52°C
Core Adsorption
R404A R404A Capacity (g)
R134a R22 R407C R134a R22 R407C
R507 R507
A2F-D 2.8 2.5 2.9 4.8 2.3 1.9 2.3 5.0 3.7
A3F-D 7.6 6.8 8.0 13.3 6.3 5.3 6.2 13.8 10.3
A4F-D 14.8 13.3 15.7 25.9 12.2 10.3 12.2 26.9 20.1
A5F-D 21.8 19.6 23.1 38.2 18.0 15.1 17.9 39.7 29.6

Accessories and spare parts


Repair Kits with Cover, Screws and Gaskets Type Part No.
Repair Kit BTAS 2 KD 30519-2 065970
Repair Kit BTAS 3 KD 30519-3 065971
Repair Kit BTAS 4 KD 30519-4 065972
Repair Kit BTAS 5 KD 30519-5 065973

277 GPC-EN-2024 CONTROLS COMPONENTS


Moisture / liquid indicators AMI, MIA & CIA
The AMI / MIA / CIA series of Moisture Indicators are designed to monitor
the moisture content within the liquid line of a refrigeration system.
MIA and CIA series with stainless steel body and extended copper tube
connections are fully hermetic products without the use of any gasket.
AMI is a highly serviceable product with exchangeable lens assembly and
indicator element. available in various configurations including saddle type.

Features
• Max. allowable pressure PS: AMI
- AMI: 35 bar
- MIA: 45 bar
- CIA: 60 bar for subcritical CO2 & R32
• MIA/CIA released for A2L refrigerants: R32, R452B, R454C, R454B,
R454A, R1234yf
• Crystal indicator element for long lifetime and reliability
• Highest sensitivity moisture indicator available
• Indication of dryness according to ASERCOM recommendation
• Easy determination of moisture content with calibrated four colors MIA / CIA
• Large clear viewing area
• AMI sight glass with grooves to distinguish between pure liquid and
pure vapor

Selection table MIA & CIA


For Tube Outside Medium
Markings
Diameter Compatibility
Type Part No. Configuration Picture
UL CSA CE
(mm) (inch) A1 A2L
SA4876 Canada Cat. I PED

6 MIA M06 805880

1/4” MIA 014 805883

10 MIA M10 805881

3/8” MIA 038 805884 R134a  


Female solder R452B
12 MIA M12 805882 R22
x
female solder R454A
1/2” MIA 012 805885 R404A
ODF x ODF
16 5/8” MIA M16 / 058 805886 R454B
R407C
R1234yf
22 7/8” MIA 078 805887 R507 
R454C
28 MIA M28 805891 R513A
 
1-1/8” MIA 118 805892 R410A
MIA M10S Female solder
10 805888
female/male x
male solder  
MIA M10S
12 805889 ODF x ODF
female/male

6 CIA M06 805914

1/4” CIA 014 805910

10 CIA M10 805915 Female solder


x
3/8” CIA 038 805911
female solder
CO2 R32  
12 CIA M12 805916 ODF x ODF

1/2” CIA 012 805912

16 5/8” CIA M16 / 058 805913

GPC-EN-2024 CONTROLS COMPONENTS 278


Selection table - AMI

For Tube Outside Medium


Markings
Diameter Compatibility
Type Part No. Configuration CE Picture
UL CSA
(mm) (inch) A1 Cat. I UKCA
SA4876 Canada
PED
6 AMI-1 TT2 MM 805697

1/4” AMI-1 TT2 805655

10 AMI-1 TT3 MM 805698

3/8” AMI-1 TT3 805654


Female solder
12 AMI-1 TT4 MM 805699 x
1/2” AMI-1 TT4 805653 female solder  
ODF x ODF
16 5/8” AMI-1 TT5 805652

22 7/8” AMI-1 TT7 805656

28 AMI-1 TT9 MM 805700

1-1/8” AMI-1 TT9 805651


6 AMI-1 SS2 MM 805732
1/4” AMI-1 SS2 805713

10 AMI-1 SS3 MM 805733

3/8” AMI-1 SS3 805714


Female solder
12 AMI-1 SS4 MM 805734 x
1/2” AMI-1 SS4 805715 female solder R134a  
ODF x ODF
16 5/8” AMI-1 SS5 805716 R22

22 7/8” AMI-1 SS7 805717 R404A


28 AMI-1 SS9 MM 805703
R407C
1-1/8” AMI-1 SS9 805705
R507
6 1/4” AMI-1 MM2 805706
R513A
10 3/8” AMI-1 MM3 805707 Male flare
x  
12 1/2” AMI-1 MM4 805708 male flare

16 5/8” AMI-1 MM5 805709

6 1/4” AMI-1 FM2 805710


Female flare
10 3/8” AMI-1 FM3 805711 x  
male flare
12 1/2” AMI-1 FM4 805712

35 1-3/8” AMI-2 S11 805704


Male solder
ODM
42 1-5/8” AMI-2 S13 805659
(for soldering    
into fittings)
54 2-1/8” AMI-2 S17 805687 
22 7/8” AMI-3 S7 805650

28 1-1/8” AMI-3 S9 805649 Saddle type


(for soldering  
onto the pipe)
35 1-3/8” AMI-3 S11 805648

Accessories for AMI


Type Part No. Description
X 12978-1 805742 Lens assembly kit
X 99995 805643 O-Ring

279 GPC-EN-2024 CONTROLS COMPONENTS


Technical data
AMI 35 bar Installation Location In any position
Maximum Allowable
MIA 45 bar
Pressure PS Pressure Drop Negligible
CIA 60 bar
AMI 39 bar Standards EN 12178
Test Pressure PT MIA 49.5 bar
CIA 66 bar
UL: see SA 4876
Operating Temperature TS -40…+100 °C CSA for Canada:
AMI series except AMI-3
Medium Compatibility Marking
MIA series except MIA-078
A1 (Fluid Group II):
AMI/MIA: R134a, R22, R404A, R407C, AMI > 32 mm
R507, R513A belong to Cat. I of the PED 2014/68/EU
MIA only: R410A
CIA only: R744
A2L (Fluid Group I):
MIA only: R452B, R454A, R454B,
R1234yf, R454C
CIA only: R32
(Not released for use with caustic,
poisonous or flammable substances)

Crystal indicator
Where many products in the market use insensitive and technically simple paper indicators. Copeland has retained the long established
crystal moisture indicators in all existing product series because of its known advantages. This guarantees system performance by
providing a sensitive and durable monitoring of the systems moisture content. enabling the indicator to react to a minimum moisture
level of 50 ppm specified by leading compressor manufacturers (see Asercom statement: www.asercom.org).

Moisture contents by indicator color


A1 (CIA only) A2L (CIA only)
Refrigerants
R744 R32
CIA
Liquid Temperature (°C) Liquid Temperature (°C)
Color Code
-40 -20 -10 0 +5 +20 25 38 52
Blue/
3 6 8 11 13 20 6 8 12
Dry

Purple 5 10 14 19 22 34 9 13 19
ppm

Fuchsia/
10 20 29 39 46 72 21 29 43
Caution
Rose/
16 32 46 63 75 116 34 46 69
Caution WET!

Refrigerants A1 (AMI /MIA) A2L (MIA only)


AMI/MIA Liquid R404A
R22 R134a R407C R410A R513A R452B R454B R454A R454C R1234yf
Temp. (°C) R507
25 25 15 20 26 30 15 22 24 22 22 12
Blue/
38 35 25 35 40 55 20 34 34 28 28 14
Dry
52 50 45 50 64 75 24 46 46 35 35 16
25 40 33 35 42 50 19 28 28 27 27 14

Purple 38 65 50 55 68 85 25 42 42 35 35 17

52 90 60 85 109 120 30 58 58 44 44 20
ppm

25 80 60 90 94 110 44 66 68 64 64 34
Fuchsia/
38 130 110 120 144 190 58 99 101 82 82 40
Caution
52 185 140 150 230 270 71 136 138 105 105 46
25 145 120 130 151 165 75 112 119 108 108 58
Rose/
Caution 38 205 150 160 232 290 98 168 170 138 138 68
WET!
52 290 180 190 371 420 121 230 232 177 177 78
Note: In area “Caution” and “Caution wet” filter drier should be changed.

GPC-EN-2024 CONTROLS COMPONENTS 280


281 GPC-EN-2024 CONTROLS COMPONENTS
Oil management and liquid
Electrical
level monitoring Control Valves
components

Technical information

Refrigeration compressors are lubricated by refrigeration oil Oil level management system function
that circulates from the compressor crankcase or housing.
As refrigerant gas is discharged by the compressor, it will This system provides oil level balancing as well as oil level
leave a fine oil mist that will be circulated throughout the monitoring including alarm and compressor shut-down
entire system.Small amounts of oil circulating through the functions. The oil level is measured inside the compressor‘s
system will not affect the system performance. Too much crankcase. By operating an integrated solenoid valve, missing
refrigeration oil circulating in the system will have adverse oil can be fed from the oil receiver or from the oil separator
effects on the components in the system. Circulating oil directly into the compressor sump. If the oil level drops to a
reduces the ability of the system to effectively remove the dangerous level, the alarm contact changes into alarm state.
heat. Condensers, evaporators and other heat exchangers The alarm contact may be used to shut down the compressor.
lose efficiency when coated internally with an oil film. The integrated electronics include delay times in order to
avoid short-cycling and nuisance alarms.
Oil not returning to the compressor causes improper
lubrication and eventual compressor failure. At low This system applies to compressor pack applications with
temperature application, oil thickness becomes difficult to multiple parallel compressor arrangements, but also to stand-
move, causing oil to be trapped in the system. alone compressor applications for compressors without
differential oil pressure monitoring.
Oil separator function
Liquid level monitoring
Refrigerant gas leaving the compressor through the
discharge line contains refrigeration oil in a vaporous mist. As LW4 and LW5 are self-contained units intended for liquid
this mixture enters the oil separator, the velocity is reduced to level monitoring at the sight glass or plugged connection of
allow oil separation to begin. vessels, maintaining a permanent visibility of the liquid level
versus other liquid level sensors. There are two versions for
The refrigerant gas and oil mixture enters the oil separator monitoring maximum or minimum liquid level. LW can be
and passes through an inlet screen, causing the fine particles applied to a variety of media such as liquid refrigerants as well
to combine. Larger oil particles are formed and drop to the as oil.
bottom of the oil separator.
The typical application are in liquid receivers, oil separators, oil
The refrigerant gas then passes through an outlet screen to reservoirs and flash tanks.
remove residual oil particles. The oil gathers in the bottom of
the oil separator until a float operated needle valve opens to
allow the return of oil to the compressor. Oil returns quickly
to the compressor, because of the higher pressure in the
oil separator than in the compressor crankcase. When the
oil level has lowered, the needle valve retracts to prevent
refrigerant gas from returning back to the compressor. The
refrigerant gas leaves through the outlet of the oil separator
and goes to the condenser.

GPC-EN-2024 CONTROLS COMPONENTS 282


OM3, OM4 and OM5 TraxOil™ oil management
The TraxOil oil management is a self-contained and reliable
electronically controlled system with an integrated solenoid valve,
which feeds missing oil directly into the compressor sump. The sight
glass function remains fully available, status and level information is
indicated by LED’s. The integrated alarm function with compressor shut
down completes the overall proven solution for compressor protection.
OM3 and OM4 are released for A2L refrigerants:
• The power supply must be 24 VAC only.
• The voltage of alarm contact is max. 24 VAC.
While OM3 is the well-proven solution for HFC refrigerants, OM4 can
also be used for subcritical CO2 systems.
OM5 TraxOil has been specially developed for transcritical CO2 OM5 + ESC-W Coil 24V
applications, the new adapters are equipped with special types of
O-rings to guarantee safe long-term and reliable operation.

Features

• OM3 for selected HFC and HFO/HFO blends refrigerants


- Max. allowable pressure PS: 46 bar
• OM4 for liquid R744 (CO2) subcritical and selected HFC
and HFO/HFO blends refrigerants
- Max. allowable pressure PS: 60 bar
• OM5 for liquid R744 (CO2) transcritical
- Max. allowable pressure PS: 130 bar
- Max. operating pressure differential MOPD: 100 bar
- CO2 optimized gasket material
- Adapters with CO2 optimized gasket material OM4 + ESC Coil 230V + OM-230V
- High wattage ESC-W coil to achieve high pressure
differential MOPD of 100 bar
• Self-contained unit with oil level sensor and integral • SPDT output contact for compressor shut down or
solenoid to manage oil level supply alarming, rating 230 VAC / 3 A
• 3-Zone level control by using precise Hall-Sensor • Easy installation by sight-glass replacement and front
measurement, not prone to errors by foaming or light like side mounting without nuts
optical sensors • Adapters suitable for various types of compressors
• Alarm, status and level indication by LED’s • Recommended by leading compressor manufacturers
• Supply 24 VAC or 230 VAC • marking under LVC and EMC Directive

283 GPC-EN-2024 CONTROLS COMPONENTS


Selection table OM3 and OM4 (select one item of each group)

1. Base units (supplied without adapter and coil)


Max. Allowable Time Delay
Type Part No.
Pressure PS Alarm
OM3-020 805133 20 Sec
46 bar
OM3-120 805134 120 Sec
OM4-020 805135 20 Sec
60 bar
OM4-120 805136 120 Sec

2. Adapter
OM0-CUA 805037 Flange Adapter 3- / 4-Hole
OM0-CBB 805038 Screw Adapter 1-1/8”-18 UNEF
OM0-CCA 805039 Screw Adapter 3/4”-14 NPTF
OM0-CCB 805040 Screw Adapter 1-1/8”-12 UNF
OM0-CCC 805041 Flange Adapter 3-Hole
OM0-CCD 805042 Rotalock Adapter 1-3/4”-12UNF
OM0-CCE 805043 Rotalock Adapter 1-1/4”-12UNF
OM0-CCL 805261 Braze adapter Ø22.5 mm

Note: For use with A2L refrigerants, only the OM0-CCL can be used.

3. Cables alarm relay


OM3-N30 805 141 Connection to Relay 3 m
OM3-N60 805 142 Connection to Relay 6 m
OM3-N100 805 146 Connection to Relay 10 m

Supply Voltage 24V Supply Voltage 230V

4. Solenoid coil 4. Solenoid coil


Type Part No. Type Part No.
ESC-24VAC 801033 50 Hz, 17 VA ESC-230 VAC 801031 50 Hz, 17 VA

5. Cable assembly power supply and solenoid 5. Cable assembly with 230V module
OM3-P30 805151 24V, 3 m OM-230V-30 805166 230V, 3.0 m
OM3-P60 805152 24V, 6 m OM-230V-60 805167 230V, 6.0 m
OM3-P100 805153 24V, 10 m OM-230V-100 805168 230V, 10.0 m

Note: For A2L, the power supply must be 24VAC only.

Oil management kits including adapter and 24V coil: cross reference
Kit Inc. Adapter Part No. Base Unit Part No. Adapter Part No. Coil Part No.
OM3-CUA 805301 OM0-CUA 805037
OM3-CBB 805303 OM0-CBB 805038
OM3-CCA 805304 OM0-CCA 805039
OM3-CCB
OM3-CCC
OM3-CCD
805305
805306
805302
 OM3-020 805 133
OM0-CCB
OM0-CCC
OM0-CCD
805040
805041
805042
ESC 24 VAC 801 033

OM3-CCE 805300 OM0-CCE 805043


OM3-CCL (A2L) 805126 OM0-CCL 805261

OM4-CUA 805307 OM0-CUA 805337


OM4-CBB 805309 OM0-CBB 805338
OM4-CCA 805310 OM0-CCA 805339
OM4-CCB
OM4-CCC
OM4-CCD
805311
805312
805308
 OM4-020 805 135
OM0-CCB
OM0-CCC
OM0-CCD
805340
805341
805342
ESC 24 VAC 801 033

OM4-CCE 805313 OM0-CCE 805343


OM4-CCL (A2L) 805129 OM0-CCL 805261

GPC-EN-2024 CONTROLS COMPONENTS 284


Selection table OM5 (select one item of each group)

1. Base units (supplied without adapter and coil)


Max. Allowable Time Delay
Type Part No.
Pressure PS Alarm
OM5-020 805230 20 Sec
130 bar
OM5-120 805231 120 Sec

2. Adapter
OM0-CUA CO2 805337 Flange Adapter 3- / 4-Hole
OM0-CCC CO2 805341 Flange Adapter 3-Hole
OM0-CUD CO2 805049 Flange Adapter 6- / 6-Hole
OM0-CBB CO2 805338 Screw Adapter 1-1/8”-18 UNEF
OM0-CCA CO2 805339 Screw Adapter 3/4”-14 NPTF
OM0-CCB CO2 805340 Screw Adapter 1-1/8”-12 UNF
OM0-CCD CO2 805342 Rotalock Adapter 1-3/4”-12UNF
OM0-CCE CO2 805343 Rotalock Adapter 1-1/4”-12UNF

3. Cables alarm relay


OM3-N30 805141 Connection to Relay 3 m
OM3-N60 805142 Connection to Relay 6 m
OM3-N100 805146 Connection to Relay 10 m

4. Solenoid coil 4. Solenoid coil


Supply Voltage 24V Supply Voltage 230V
Type Part No. Description Type Part No. Description
ESC-W24VAC 801028 50 Hz, 38 VA ESC-W230VAC 801029 50 Hz, 38 VA

5. Cable assembly power supply and solenoid 5. Cable assembly with 230V module
OM3-P30 805151 24V, 3.0 m OM-230V-30 805166 230V, 3.0 m
OM3-P60 805152 24V, 6.0 m OM-230V-60 805167 230V, 6.0 m
OM3-P100 805153 24V, 10.0 m OM-230V-100 805168 230V, 10.0 m

Accessories and spare parts


Type Part No. Description
ECT-623 804421 Transformer 230 VAC / 24 VAC, 60 VA (Supply of 3 pieces base unit)
ESC-K01 801080 Retainer kit ESC including O-Rings
ODP-33A 800366 Differential oil check valve 3.5 bar, PS: 46 bar (Inlet 5/8”-UNF female, Outlet 5/8”- UNF male)
OM3-K01 805036 Repair kit OM3/OM4 (Consists of sight glass with O-Ring and screws, oil adapter with strainer, O-Ring back side)
OM5-K01 805067 Repair kit OM5 for CO2 (Consists of sight glass with O-Ring and screws, Oil adapter with strainer, O-Ring back side)
OM-HFC-K01 805081 Sealing kit OM3/OM4 (Consists of all O-Rings for OM3/OM4 and for all types of adapters)
OM-HFC-K02 805083 Enclosing tube for OM3/OM4 (Including O-Ring), only for replacement of new version with hexagonal nut!
OM-CO2-K01 805079 Sealing kit CO2 for OM5 (Consists of all O-Rings for OM5 and for all types of adapters)
OM-CO2-K02 805082 Enclosing tube for OM5 (Including O-Ring), only for replacement of new version with hexagonal nut!

285 GPC-EN-2024 CONTROLS COMPONENTS


Technical data
Under: OM3/OM4 at ΔP =3 bar: 340g/min.
- Low Voltage Directive Flow Rate (22°C Oil Temperature, Oil type HM46)
- EMC Directive OM5: See Fig. 1
Markings Orientation of Base Unit horizontal, +/- 1°

for OM3 & OM4 Level Control 40% to 60% of Sight Glass height
Max. 3 A, 230 VAC,
Alarm Contact (max. 24VAC for A2L)
OM3: 46 bar
Max. Allowable Pressure PS SPDT dry contact
OM4: 60 bar
OM5: HP Side (Inlet): 130 bar 20 Sec.: OM3/4/5-020, All OM3/4 Kits
Time Delay Alarm
LP Side (Outlet): 100 bar 120 Sec.: OM3/4/5-120
OM3: 51 bar Time Delay Filling 10 Sec.
Max. Test Pressure PT
OM4: 66 bar IP 65 with plug/cable assembly acc.
OM5: 143 bar Protection Class
EN 60529 test conditions
Supply Voltage / Total Power 7/16”-20 UNF Male, with Strainer and
• With ESC-24VAC Coil OM3/OM4: Max. 24 VAC for A2L Oil Connection
O-Ring (Replaceable, See Acc.)
• With ESC-230VAC Coil 24 VAC±10%, 50 Hz, 17 VA
and OM-230V-x Module 230 VAC±10%, 50 Hz, 17 VA Replaceable for Cleaning, Hexagon
Enclosing Tube
Wrench Size 18, See Spare Parts
• With ESC-W24VAC Coil only OM5:
24VAC, 50 Hz, ±10%, 38 VA
OM3/OM4: 30 bar
Solenoid Valve MOPD
OM5: 100 bar (50 Hz) See Fig. 1
Medium Temperature -20…+80°C
Ambient/Storage Temperature -20…+50°C
OM3/OM4:
A1: R134a, R404A, R407C, R450A,
R452A, R448A, R449A, R507,
R513A, R410A

Medium Compatibility A2L: R32, R452B, R454B, R454A,


R454C, R455A, R1234ze, R1234yf,
Note: A2L only with oil: Emkarate RL-
3MAF, R32 only with SP32 oil type

OM4/OM5: R744

Fig. 1: OM5: performance related to supply voltage: flow rate and differential pressure between inlet and outlet
(oil type Reniso C85E, oil temperature 54°C)

Supply voltage 24V/230V, 50 Hz -0% Supply voltage 24V/230V, 50 Hz -10%

5000 5000

4000 4000

3000 3000
g/min

g/min
Range limit

Range limit

2000 2000

1000
Working range 1000
Working range

0 0
20 50 80 100 20 50 80 100

Differential pressure (bar) Differential pressure (bar)

GPC-EN-2024 CONTROLS COMPONENTS 286


287 GPC-EN-2024 CONTROLS COMPONENTS
Electronic oil level monitoring TraxOil™ OW4 and OW5

OW4 and OW5 TraxOil are intended for systems which require
oil level monitoring and alarming instead of active oil level
balancing.

Features

• OW4 for CO2 subcritical and selected HFC and HFO/HFO


blends refrigerants
- Max. allowable pressure PS: 60 bar
• OW5 for CO2 transcritical
- Max. allowable pressure PS: 100 bar OW4 TraxOil
- CO2 optimized gasket material, not released for HCFC
and HFCs
- Adapters with CO2 optimized gasket material
• 3 Zone level control by using precise Hall-sensor
measurement, not prone to errors by foaming or light like
optical sensors
• Alarm, status and 3 zone indication by LED’s
• SPDT output contact for compressor shut down or
alarming, rating 230 VAC / 3 A
• Easy installation by sight-glass replacement and front
side mounting without nuts
• Supply 24 VAC, 50/60 Hz
• Recommended by leading compressor manufacturers
• marking under Low Voltage and EMC Directive OW5 TraxOil

Selection table (select one item of each group)


1. Base units (supplied without adapter)
Max. Allowable Time Delay
Type Part No.
Pressure Alarm
OW4-020 805116 60 bar 20 sec

2. Adapter
OM0-CUA 805037 Flange Adapter 3-/4-Hole
OM0-CCC 805041 Flange Adapter 3-Hole
OM0-CBB 805038 Screw Adapter 1-1/8”-18 UNEF
OM0-CCA 805039 Screw Adapter 3/4”-14 NPTF
OM0-CCB 805040 Screw Adapter 1-1/8”-12 UNF
OM0-CCD 805042 Rotalock Adapter 1-3/4”-12UNF
OM0-CCE 805043 Rotalock Adapter 1-1/4”-12UNF
OM0-CCL 805 261 Braze adapter Ø22.5 mm

Note: For use with A2L refrigerants, only the OM0-CCL can be used.

3. Relay cables
OM3-N30 805141 Connection to Relay 3.0 m
OM3-N60 805142 Connection to Relay 6.0 m
OM3-N100 805146 Connection to Relay 10.0 m

4. Power cables
Type Part No. Description Cable Length
Connection to
OW-24V-3 804672 Power Supply 3.0 m
24VAC

GPC-EN-2024 CONTROLS COMPONENTS 288


Product selection (select one item of each group)

1. Base units (supplied without adapter)


Max. Allowable Time Delay
Type Part No.
Pressure PS (bar) Alarm
OW5-120 805241 100 bar 120 Sec

2. Adapter
OM0-CUA CO2 805337 Flange Adapter 3-/4-Hole
OM0-CCC CO2 805341 Flange Adapter 3-Hole
OM0-CUD CO2 805049 Flange Adapter 6-/6-Hole
OM0-CBB CO2 805338 Screw Adapter 1-1/8”-18 UNEF
OM0-CCA CO2 805339 Screw Adapter 3/4”-14 NPTF
OM0-CCB CO2 805340 Screw Adapter 1-1/8”-12 UNF
OM0-CCD CO2 805342 Rotalock Adapter 1-3/4”-12UNF
OM0-CCE CO2 805343 Rotalock Adapter 1-1/4”-12UNF

3. Relay cables
OM3-N30 805141 Connection to Relay 3.0 m
OM3-N60 805142 Connection to Relay 6.0 m
OM3-N100 805146 Connection to Relay 10.0 m

4. Power cables
Type Part No. Description Cable Length
Connection to
OW-24V-3 804672 power supply 3.0 m
24 VAC

Accessories and spare parts


Type Part No. Description
ECT-623 804421 Transformer 230 VAC / 24 VAC, 60 VA (Supply of 3 Pieces Base Unit)
OM-HFC-K01 805081 Sealing Kit OW4 (Consists of All O-Rings, Incl. Adapter Gaskets)
OM-CO2-K01 805079 Sealing Kit OW5 (Consists of All O-Rings, Incl. Adapter Gaskets)

Technical data
Orientation of Base Unit Horizontal, +/- 1°
Under: Level Control 40%...60% Sight Glass Height
Markings - Low Voltage Directive
Max. 3 A, 230 VAC
- EMC Directive Alarm Contact
SPDT Dry Contact
Max. Allowable Pressure PS OW4: 60 bar OW5: 100 bar Time Delay Alarm 20 Sec or 120 Sec
Max. Test Pressure PT OW4: 66 bar OW5: 110 bar IP 65 with plug/cable assembly
Protection Class
Supply Voltage Current 24 VAC, 50/60 Hz, ±10%, 0.05 A acc. EN 60529 test conditions
Medium Temperature -20...80°C
Ambient/Storage Temperature -20...50°C
OW4:
A1: R134a, R404A, R407C, R450A,
R452A, 448A, R449A, R507,
R513A, R410A

A2L: R32, R452B, R454B, R454A,


Medium Compatibility R454C, R455A, R1234ze,
R1234yf

Note: A2L only with oil: Emkarate RL-3MAF,


R32 only with SP32 oil type

OW4/OW5: R744

289 GPC-EN-2024 CONTROLS COMPONENTS


Level watch LW4 and LW5 liquid level control
LW4 and LW5 are self-contained units intended for liquid level
monitoring and control at the sight glass connection of ves-
sels, maintaining a permanent visibility of the liquid level versus
other liquid level sensors.

Features
• LW4 for liquid CO2 , selected HFC and HFO/HFO blends
refrigerants and oil
- Max. allowable pressure PS: 60 bar
• LW5 for liquid CO2 and oil
- Max. allowable pressure PS: 130 bar
- CO2 optimized gasket material, not released for HFCs
- Adapters with CO2 optimized gasket material LW4
• Two Versions of each model:
- LW4/5-H for high liquid level monitoring
- LW4/5-L for low liquid level monitoring
• 3 Zone level control by using precise Hall-sensor
measurement, not prone to errors by foaming or light like
optical sensors
• Alarm, status and 3 zone indication by LED’s
• Dual monitoring and protection:
• 24 V output signal for critical liquid levels
• SPDT output contact for alarming, rating 230 VAC / 3 A
• Easy installation by sight-glass replacement and front side
mounting without nuts LW5
• Supply 24 VAC, 50/60 Hz
• marking under LVD and EMC Directive

Selection table (select one item of each group)

1. Base units (supplied without adapter)


Max. Allowable Liquid Vessel
Type Part No. Medium
Pressure Connection ø
LW4-H120 805491
Larger than 1/2”
LW4-L120 805490 HFC, HFO/HFO
60 bar
LW4X-H120 805494 blends, CO2 , Oil
1/2”
LW4X-L120 805493

2. Adapter
OM0-CUA 805037 Flange Adapter 3-/4-Hole
OM0-CCC 805041 Flange Adapter 3-Hole
OM0-CBB 805038 Screw Adapter 1-1/8”-18 UNEF
OM0-CCA 805039 Screw Adapter 3/4”-14 NPTF
OM0-CCB 805040 Screw Adapter 1-1/8”-12 UNF
OM0-CCD 805042 Rotalock Adapter 1-3/4”-12UNF
OM0-CCE 805043 Rotalock Adapter 1-1/4”-12UNF
LW0-1/2 805256 Screw adapter 1/2”-14 NPTF

3. Cables alarm relay


OM3-N30 805141 Connection to Relay 3.0 m
OM3-N60 805142 Connection to Relay 6.0 m
OM3-N100 805146 Connection to Relay 10.0 m

4. Cable power supply


LW-24V-3 805500 Connection to Power Supply 24V AC 3.0 m
LW-24V-6 805501 Connection to Power Supply 24V AC 6.0 m
LW-24V-10 805502 Connection to Power Supply 24V AC 10.0 m

GPC-EN-2024 CONTROLS COMPONENTS 290


Selection table (select one item of each group)
1. Base units (supplied without adapter)
Max. Allowable Liquid Vessel
Type Part No. Medium
Pressure Connection ø
LW5-H120 805481 130 bar
Larger than 1/2”
LW5-L120 805480 130 bar
CO2, Oil
LW5X-H120 805484 130 bar
1/2”
LW5X-L120 805483 130 bar

2. Adapter
LW0-CCA CO2 805254 Screw Adapter 3/4”-14 NPTF Steel
LW0-1/2 CO2 805257 Screw adapter 1/2”-14 NPTF

3. Cables alarm relay


OM3-N30 805141 Connection to Relay 3.0 m
OM3-N60 805142 Connection to Relay 6.0 m
OM3-N100 805146 Connection to Relay 10.0 m

4. Cable power supply


LW-24V-3 805500 Connection to Power Supply 24V AC 3.0 m
LW-24V-6 805501 Connection to Power Supply 24V AC 6.0 m
LW-24V-10 805502 Connection to Power Supply 24V AC 10.0 m

Accessories and spare parts


Type Part No. Description
ECT-623 804421 Transformer 230 VAC / 24 VAC, 60 VA
OM-HFC-K01 805081 Sealing-Kit LW4 (Contains All Gaskets Incl. Adapter Gaskets)
OM-CO2-K01 805079 Sealing-Kit LW5 for CO2 (Contains All Gaskets Incl. Adapter Gaskets)

Function
LW Liquid Level Monitoring Systems use a Hall-Sensor to The hall sensor converts these magnetic field changes into an
measure the liquid levels. Unaffected from foaming oil or light equivalent signal, which is used by the integrated electronic
a magnetic float changes its position according to the oil level. controller to monitor the actual liquid level by LEDs.

Technical data
Under: Orientation of Base Unit Horizontal, +/- 1°
Marking - Low Voltage Directive Level Control 30%...60% Sight Glass Height
- EMC Directive Max. 3 A, 230 VAC
Alarm Contact
Max. Allowable Pressure PS LW4: 60 bar LW5: 130 bar SPDT Dry Contact
Max. Test Pressure PT LW4: 66 bar LW5: 143 bar 24 VAC
Output Signal
Supply Voltage Current 24 VAC, 50/60 Hz, ±10%, 0.05 A Inductive Load: 35 VA
Medium Temperature -20...80°C Time Delay Alarm 120 Sec
Ambient/Storage Temperature -20...50°C Protection Class IP 65 (IEC529/EN 60529)
LW4:
R410A, R134a, R22, R404A, R507,
R407C, R1234ze, R448A, R449A,
R450A, R513A, R452A, R744
Medium Compatibility
LW5: R744

Mineral, Synthetic and Ester


Lubricants

291 GPC-EN-2024 CONTROLS COMPONENTS


Oil separator series OS
Features
• Three different construction styles:
- Hermetic
- Top flange
- Bottom flange with support bracket
• Stainless steel needle valve and floater
• Permanent magnet to catch iron particles out of the system
• Corrosion-resistant epoxy powder coating
• ODF Copper fittings for easy brazing
• Temperature range TS: -10°C ... +150°C
• Max. allowable pressure PS: 31 bar
• marking according PED
• pending OSH OST

Type code
OS X - X XX
Product Name ODF
ODF Connection
Oil Separator Ö
04 1/2”
OSB
05 5/8“ (16 mm)
Construction
07 7/8“ (22 mm)
H Hermetic
09 1-1/8“
T Top Flange
11 1-3/8“ (35 mm)
B Bottom Flange with supporter
13 1-5/8“
Nominal Shell Diameter 17 2-1/8” (54 mm)
4 ~ 10 cm
6 ~ 15 cm

Selection table

A1
Connection ODF Nominal Capacity (kW)
Type Part No. Volume (l)
R404A/
(Inch) (mm) R407C R134a R448A R449A R450A R513A R452A
R507
OSH-404 881598 1/2” 7.0 4.9 7.3 7.4 7.9 4.6 4.7 TBD 2.0
OSH-405 881599 5/8” 16 18.7 13.1 19.4 18.8 20.1 11.7 12.1 TBD 2.4
OSH-407 881600 7/8” 22 28.1 19.7 29.0 29.9 32.1 18.6 19.2 TBD 2.8
OSH-409 881792 1-1/8” 37.4 26.2 38.7 40.9 43.9 25.4 26.3 TBD 3.0
OSH-411 881794 1-3/8” 35 46.8 32.8 48.4 49.3 52.9 30.7 31.7 TBD 3.6
OSH-611 881940 1-3/8” 35 65.5 45.9 67.8 68.7 73.6 42.7 44.1 TBD 3.6
OSH-413 881856 1-5/8” 51.5 36.1 53.3 60.6 65.0 37.7 38.9 TBD 6.5
OSH-613 881953 1-5/8” 65.5 45.9 67.8 71.7 76.8 44.5 46.0 TBD 7.9
OSH-642 889022 42 65.5 45.9 67.8 71.7 76.8 44.5 46.0 TBD 7.9
OSH-617 881970 2-1/8” 54 105.3 73.8 108.9 108.7 116.5 67.5 69.8 TBD 7.9
OST-404 881860 1/2” 7.0 4.9 7.3 7.4 7.9 4.6 4.7 TBD 1.8
OST-405 881861 5/8” 16 18.7 13.1 19.4 18.8 20.1 11.7 12.1 TBD 2.6
OST-407 881862 7/8” 22 28.1 19.7 29.0 29.9 32.1 18.6 19.2 TBD 3.2
OST-409 881863 1-1/8” 37.4 26.2 38.7 40.9 43.9 25.4 26.3 TBD 3.8
OST-411 881938 1-3/8” 35 46.8 32.8 48.4 49.3 52.9 30.7 31.7 TBD 3.8
OST-413 881939 1-5/8” 65.5 45.9 67.8 68.7 73.6 42.7 44.1 TBD 3.8
OSB-613 881971 1-5/8” 65.5 45.9 67.8 71.7 76.8 44.5 46.0 TBD 7.8
OSB-617 881972 2-1/8” 54 105.3 73.8 108.9 108.7 116.5 67.5 69.8 TBD 7.8
Note: *) Applied higher module as required

GPC-EN-2024 CONTROLS COMPONENTS 292


Selection table

A2L
Connection ODF Nominal Capacity (kW)
Part
Type Volume (l)
No.
(Inch) (mm) R1234ze R455A R452B R1234yf R454A R454B R454C

OSH-404-L 881601 1/2” 3.9 6.5 10.3 4.5 6.5 8.9 5.7 2.0
OSH-405-L 881602 5/8” 16 9.9 14.9 23.8 10.4 15 20.4 13.1 2.4
OSH-407-L 881603 7/8” 22 15.8 26.4 42.1 18.3 26.5 36 23.2 2.8
OSH-409-L 881604 1-1/8” 21.6 36.1 57.6 25.1 36.3 49.3 31.8 3.0
OSH-411-L 881605 1-3/8” 35 26 43.6 69.4 30.3 43.7 59.4 38.3 3.6
OSH-413-L 881607 1-5/8” 32 - - - - - - 6.5
OST-404-L 881611 1/2” 3.9 6.5 10.3 4.5 6.5 8.9 5.7 1.8
OST-405-L 881612 5/8” 16 9.9 14.9 23.8 10.4 15 20.4 13.1 2.6
OST-407-L 881613 7/8” 22 15.8 26.4 42.1 18.3 26.5 36 23.2 3.2
OST-409-L 881614 1-1/8” 21.6 36.1 57.6 25.1 36.3 49.3 31.8 3.8
OST-411-L 881615 1-3/8” 35 26 43.6 69.4 30.3 43.7 59.4 38.3 3.8
OST-413-L 881616 1-5/8” 36.2 46.5 74.1 32.3 46.7 63.4 40.9 3.8

Spare part
Part No. Description
808800 Gasket set for OSB/OST

293 GPC-EN-2024 CONTROLS COMPONENTS


Suction accumulators
Electrical Control Valves
and ball valves

Suction accumulators
Features
• Hermetic design
• ODF Copper fittings for easy brazing
• Corrosion-resistant epoxy powder coating
• Internal orifice with strainer for optimum oil return
• Temperature range TS: -45°C...+65°C
• Max. allowable pressure PS:
20.7 bar (-10°C...+65°C)
15.5 bar (-45°C...-10°C)
• marking for certain types according PED
• UL/CUL file number: SA 34115 A08
• pending

Type code
A XX - X XX
Product Line
ODF Connection
Suction Accumulators
04: 1/2“
05: 5/8“(16 mm)
Nominal Shell Length (~inch)
07: 7/8“(22 mm)
06 11 17 08
09: 1-1/8“
12 20 09 13
11: 1-3/8“(35 mm)
25 10 14
13: 1-5/8“
Nominal Shell Diameter
4: approx. 10 cm 6: approx. 15 cm
5: approx. 13 cm 7: approx. 15 cm

GPC-EN-2024 CONTROLS COMPONENTS 294


Selection table
Nominal Capacity (kW)
Conformity
Connection R404A / R448A / Assessment

Volume (l)*
R407C R134a R450A R513A R410A R1234ze
R507 R449A
Part
Type

Procedure
No.

Category
Inch
mm

Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min.

A08-304 001973 1/2“ 7.0 1.1 4.2 0.6 4.6 0.7 4.1 0.6 3.7 0.6 7.2 1.1 8.6 1.3 3.5 0.5 0.73
A10-305 001977 16 5/8“ 10.5 1.6 6.0 0.9 7.0 1.1 5.8 0.9 5.2 0.8 10.8 1.6 12.9 1.9 5.0 0.8 0.93
A06-405 001989 16 5/8“ 10.5 1.6 6.0 0.9 7.0 1.1 5.8 0.9 5.2 0.8 10.8 1.6 12.9 1.9 5.0 0.8 0.93
CE Marking
A12-305 001978 16 5/8“ 10.5 1.6 6.0 0.9 7.0 1.1 5.8 0.9 5.2 0.8 10.8 1.6 12.9 1.9 5.0 0.8 Not Required 1.16
A12-306 001979 3/4“ 14.0 2.1 8.1 1.2 9.1 1.4 7.8 1.2 7.1 1.1 14.4 2.2 17.1 2.6 6.7 1.0 1.16
Cat. I/
A14-305 001980 16 5/8“ 10.5 1.6 6.0 0.9 7.0 1.1 5.8 0.9 5.2 0.8 10.8 1.6 12.9 1.9 5.0 0.8 1.40
Mod. A
A14-306 001987 3/4“ 14.0 2.1 8.1 1.2 9.1 1.4 7.8 1.2 7.1 1.1 14.4 2.2 17.1 2.6 6.7 1.0 1.40
A10-405 001990 16 5/8“ 10.5 1.6 6.0 0.9 7.0 1.1 5.8 0.9 5.2 0.8 10.8 1.6 12.9 1.9 5.0 0.8 1.75
A10-406 001994 3/4“ 14.0 2.1 8.1 1.2 9.1 1.4 7.8 1.2 7.1 1.1 14.4 2.2 17.1 2.6 6.7 1.0 1.75
A09-506 881995 3/4“ 14.0 2.1 8.1 1.2 9.1 1.4 7.8 1.2 7.1 1.1 14.4 2.2 17.1 2.6 6.7 1.0 2.33
A09-507 882455 22 7/8“ 25.6 3.8 14.0 2.1 16.1 2.4 13.6 2.0 12.3 1.8 26.3 3.9 31.3 4.7 11.7 1.8 2.33
A12-506 881996 3/4“ 14.0 2.1 8.1 1.2 9.1 1.4 7.8 1.2 7.1 1.1 14.4 2.2 17.1 2.6 6.7 1.0 3.29
A12-507 881998 22 7/8“ 25.6 3.8 14.0 2.1 16.1 2.4 13.6 2.0 12.3 1.8 26.3 3.9 31.3 4.7 11.7 1.8 3.29
A13-507 882007 22 7/8“ 25.6 3.8 14.0 2.1 16.1 2.4 13.6 2.0 12.3 1.8 26.3 3.9 31.3 4.7 11.7 1.8 3.80
A13-509 882011 1-1/8“ 41.4 6.2 25.3 3.8 26.7 4.0 24.5 3.7 22.2 3.3 42.5 6.4 50.6 7.6 21.0 3.2 3.80
A17-509 882012 1-1/8“ 41.4 6.2 25.3 3.8 26.7 4.0 24.5 3.7 22.3 3.3 42.5 6.4 50.6 7.6 21.0 3.2 4.87
A17-511 882013 35 1-3/8“ 66.0 9.9 37.6 5.6 42.8 6.4 36.4 5.5 33.3 5.0 67.6 10.1 80.6 12.1 31.3 4.7 Cat. I Mod. D1 4.87
A11-607 882014 22 7/8“ 25.6 3.8 14.0 2.1 16.1 2.4 13.6 2.0 12.3 1.8 26.3 3.9 31.3 4.7 11.7 1.8 4.30
A13-607 882015 22 7/8“ 25.6 3.8 14.0 2.1 16.1 2.4 13.6 2.0 12.3 1.8 26.3 3.9 31.3 4.7 11.7 1.8 4.98
A13-609 882019 1-1/8“ 41.4 6.2 25.3 3.8 26.7 4.0 24.5 3.7 22.2 3.3 42.5 6.4 50.6 7.6 21.0 3.2 4.98
A14-611 882020 35 1-3/8“ 66.0 9.9 37.6 5.6 42.8 6.4 36.4 5.5 33.3 5.0 67.6 10.1 80.6 12.1 31.3 4.7 5.48
A17-613 882022 1-5/8“ 100.0 15.0 59.7 9.0 63.9 9.6 57.8 8.7 52.4 7.9 102.5 15.4 122.2 18.3 49.7 7.5 6.85
A17-642 889023 42 100.0 15.0 59.7 9.0 63.9 9.6 57.8 8.7 52.4 7.9 102.5 15.4 122.2 18.3 49.7 7.5 6.85
A20-613 882021 1-5/8“ 100.0 15.0 59.7 9.0 63.9 9.6 57.8 8.7 52.4 7.9 102.5 15.4 122.2 18.3 49.7 7.5 8.21
A25-613 882023 1-5/8“ 100.0 15.0 59.7 9.0 63.9 9.6 57.8 8.7 52.4 7.9 102.5 15.4 122.2 18.3 49.7 7.5 Cat II Mod. D1 10.23

Note 1: For selection of other operating conditions, please use Copeland Select software.
Note 2: *) Functional volume

295 GPC-EN-2024 CONTROLS COMPONENTS


A2L

Nominal Capacity (kW)


Conformity
Connection
Assessment

Volume (l)*
R452B R455A R454A R454B R454C R1234yf R1234ze R32
Type Part No.

Procedure
Category
Max.

Max.

Max.

Max.

Max.

Max.

Max.

Max.
Min.

Min.

Min.

Min.

Min.

Min.

Min.

Min.
mm Inch

A08-304-L 882453 5.1 0.8 7.9 1.2 7.2 1.1 5.4 0.8 8.2 1.2 3.6 0.5 3.5 0.5 11.0 1.7 0.73
CE Marking
A10-305-L 882457 16 5/8“ 7.7 1.2 11.8 1.8 10.8 1.6 8.0 1.2 12.4 1.9 5.1 0.8 5.0 0.8 16.5 2.5 0.93
Not Required
A06-405-L 882462 16 5/8“ 7.7 1.2 11.8 1.8 10.8 1.6 8.0 1.2 12.4 1.9 5.1 0.8 5.0 0.8 16.5 2.5 0.93

A12-305-L 882458 16 5/8“ 7.7 1.2 11.8 1.8 10.8 1.6 8.0 1.2 12.4 1.9 5.1 0.8 5.0 0.8 16.5 2.5 1.16

A12-306-L 882459 3/4“ 10.3 1.5 15.8 2.4 14.4 2.2 10.7 1.6 16.5 2.5 6.9 1.0 6.7 1.0 22.0 3.3 1.16

A14-305-L 882460 16 5/8“ 7.7 1.2 11.8 1.8 10.8 1.6 8.0 1.2 12.4 1.9 5.1 0.8 5.0 0.8 16.5 2.5 1.40
Cat. I Mod. A
A14-306-L 882461 3/4“ 10.3 1.5 15.8 2.4 14.4 2.2 10.7 1.6 16.5 2.5 6.9 1.0 6.7 1.0 22.0 3.3 1.40

A10-405-L 882463 16 5/8“ 7.7 1.2 11.8 1.8 10.8 1.6 8.0 1.2 12.4 1.9 5.1 0.8 5.0 0.8 16.5 2.2 1.75

A10-406-L 882464 3/4“ 10.3 1.5 15.8 2.4 14.4 2.2 10.7 1.6 16.4 2.5 6.9 1.0 6.7 1.0 22.0 3.3 1.75

A09-506-L 881994 3/4“ 10.3 1.5 15.8 2.4 14.4 2.2 10.7 1.6 16.4 2.5 6.9 1.0 6.7 1.0 22.0 3.3 2.33

A09-507-L 882456 22 7/8“ 18.8 2.8 28.8 4.3 26.2 3.9 19.5 2.9 30.1 4.5 12.1 1.8 11.7 1.8 40.2 6.0 2.33

A12-506-L 881997 3/4“ 10.3 1.5 15.8 2.4 14.4 2.2 10.7 1.6 16.4 2.5 6.9 1.0 6.7 1.0 22.0 3.3 3.29

A12-507-L 881999 22 7/8“ 18.8 2.8 28.8 4.3 26.2 3.9 19.5 2.9 30.1 4.5 12.1 1.8 11.7 1.8 40.2 6.0 3.29

A13-507-L 882000 22 7/8“ 18.8 2.8 28.8 4.3 26.2 3.9 19.5 2.9 30.1 4.5 12.1 1.8 11.7 1.8 40.2 6.0 3.80

A13-509-L 882001 1-1/8“ 30.3 4.5 46.6 7.0 42.4 6.4 31.6 4.7 48.7 7.3 21.7 3.3 21.0 3.2 64.9 9.7 3.80

A17-509-L 882002 1-1/8“ 30.3 4.5 46.6 7.0 42.4 6.4 31.6 4.7 48.7 7.3 21.7 3.3 21.0 3.2 64.9 9.7 4.87

A17-511-L 882003 35 1-3/8“ 48.3 7.2 74.2 11.1 67.5 10.1 50.3 7.5 77.5 11.6 32.3 4.8 31.3 4.7 103.4 15.5 Cat. II Mod. D1 4.87

A11-607-L 882004 22 7/8“ 18.8 2.8 28.8 4.3 26.2 3.9 19.5 2.9 30.1 4.5 12.1 1.8 11.7 1.8 40.2 6.0 4.30

A13-607-L 882005 22 7/8“ 18.8 2.8 28.8 4.3 26.2 3.9 19.5 2.9 30.1 4.5 12.1 1.8 11.7 1.8 40.2 6.0 4.98

A13-609-L 882006 1-1/8“ 30.3 4.5 46.6 7.0 42.4 6.4 31.6 4.7 48.7 7.3 21.7 3.3 21.0 3.2 64.9 9.7 4.98

A14-611-L 882008 35 1-3/8“ 48.3 7.2 74.2 11.1 67.5 10.1 50.3 7.5 77.5 11.6 32.3 4.8 31.3 4.7 103.4 15.5 5.48

A17-613-L 882009 1-5/8“ 73.2 11.0 112.5 16.9 102.4 15.4 76.3 11.4 117.5 17.6 51.3 7.5 49.7 7.5 156.8 23.5 6.85

A17-642-L 882010 42 73.2 11.0 112.5 16.9 102.4 15.4 76.3 11.4 117.5 17.6 51.3 7.5 49.7 7.5 156.8 23.5 6.85

A20-613-L 882016 1-5/8“ 73.2 11.0 112.5 16.9 102.4 15.4 76.3 11.4 117.5 17.6 51.3 7.5 49.7 7.5 156.8 23.5 8.21

A25-613-L 882017 - - - - - - - - - - - - 49.7 7.5 - - Cat II Mod. D1 10.23

GPC-EN-2024 CONTROLS COMPONENTS 296


Ball valves series BVE/BVS and CVE/CVS

Features
• BVE/S, Max. allowable pressure PS: 45 bar
• CVE/S for CO2, Max. allowable pressure PS: 60 bar
• BVS/CVS version with Schrader valve
• Two threads at valve body for easy mounting
• Hermetic design with Laser welded valve body
• Bi-directional flow characteristics
• Valve cap retained by strap attached to main body
• Pressure relief port design BVE / CVE
• Marking acc. PED (from BVE-138 up to BVE-318)
• To protect valve from unauthorized use a special seal cap
is available as accessory

BVS / CVS

Selection table BVE/BVS (UL approved) Technical data


Connection size Max. Allowable Pressure PS BVE/BVS 45 bar; CVE/CVS 60 bar
Type BVE Part No. Type BVS Part No. ODF
(inch) (mm) Test Pressure PT BVE/BVS 49.5 bar; CVE/CVS 66 bar
BVE-014 806730 BVS-014 806750 1/4” Medium Temperature TS -40 ... 120°C
BVE-M06 806731 BVS-M06 806751 6 mm
A1: R410A R134a R22 R404A R507
BVE-038 806732 BVS-038 806752 3/8” R407C R1234ze R448A R449A
BVE-M10 806733 BVS-M10 806753 10 mm R450A R513A R744 R124 R452A,
Medium Compatibility
BVE-012 806734 BVS-012 806754 1/2”
BVE-M12 806735 BVS-M12 806755 12 mm A2L: R32, R452B, R455A, R454A,
R454B, R454C, R1234yf, R1234ze
BVE-058 806736 BVS-058 806756 5/8” 16 mm
BVE-034 806737 BVS-034 806757 3/4”
BVE-078 806738 BVS-078 806758 7/8” 22 mm
BVE-118 806739 BVS-118 806759 1-1/8” Accessories - special seal caps
BVE-M28 806740 BVS-M28 806760 28 mm BVE / BVS , CVE / CVS Quantity
Part No. Thread (3)
BVE-138 806741 BVS-138 806761 1-3/8” 35 mm Valve Size Per Pack
BVE-158 806742 BVS-158 806762 1-5/8” 1/4”… 7/8” (6 … 22 mm) 806770 M18x1 10 pcs
BVE-M42 806743 BVS-M42 806763 42 mm 1 -1/8”… 1-3/8” (28 … 35 mm) 806771 M27x1 10 pcs
BVE-218 806744 BVS-218 806764 2-1/8” 54 mm 1-5/8”… 3-1/8” (42 mm) 806772 M36x1 10 pcs
BVE-258 806745 BVS-258 806765 2-5/8”
BVE-318 806746 BVS-318 806766 3-1/8”

Selection table CVE/CVS (Not UL approved)


Connection size
Type CVE Part No. Type CVS Part No. ODF
(inch) (mm)
CVE-014 808130 CVS-014 808150 1/4”
CVE-M06 808131 CVS-M06 808151 6 mm
CVE-038 808132 CVS-038 808152 3/8”
CVE-M10 808133 CVS-M10 808153 10 mm
CVE-012 808134 CVS-012 808154 1/2”
CVE-M12 808135 CVS-M12 808155 12 mm
CVE-058 808136 CVS-058 808156 5/8” 16 mm
CVE-034 808137 CVS-034 808157 3/4”
CVE-078 808138 CVS-078 808158 7/8” 22 mm

297 GPC-EN-2024 CONTROLS COMPONENTS


GPC-EN-2024 CONTROLS COMPONENTS 298
299 GPC-EN-2024 CONTROLS COMPONENTS
Appendix

Appendix

Conversion table

Power
kW / h = Kcal / h : 860 Kcal / h = kW / h x 860
kW = US Ton of Refrigeration : 0.284 US Ton of Refrigeration = kW x 0.284
kW = BTU / h : 3413 BTU / h = kW x 3413

Temperature
°C = (°F - 32) : 1.8 °F = (°C x 1.8) + 32

Pressure
Bar = PSI : 14.5 PSI = Bar x 14.5
1 Bar = 100 000 Pascal 100 Pascal = 1 m Bar

GPC-EN-2024 CONTROLS COMPONENTS 300


Connections
Connection Tube
Specification Thread
SAE Inch Metric
SAE 1/4” 1/4” 6 mm 7/16” - 20UNF
SAE 5/16” 5/16” 8 mm 5/8” - 18UNF
SAE 3/8” 3/8” 10 mm 5/8” - 18UNF
SAE 1/2” 1/2” 12 mm 3/4” - 16UNF
SAE 5/8” 5/8” 16 mm 7/8” - 14UNF
SAE 3/4” 3/4” 18 mm 1-1/16” - 14UNF
SAE 7/8” 7/8” 22 mm 1-1/4” - 12UNF
SAE Flare SAE 1” 1 25 mm 1-1/2” - 12UNF
1-1/8”
1-3/8” 35 mm
1-5/8”
2-1/8” 54 mm
2-5/8”
3-1/8”
Withworth-
R or G same as Pipe thread female
Male Thread: R / NPT / BSP / G Pipe Thread
BSP cylindrical
DIN 2999 / ISO 228
Withworth-
R same as Pipe Thread Male
Female Thread: R / NPT / BSP / G Pipe Thread
BSP Tapering
DIN 2999
Withworth-
Pipe Thread Male
G Female thread: R / BSP / G Pipe Thread
Cylindar
ISO 228

Pipe Thread Female


Male thread: R / NPT / BSP
Tapering Standard Taper
NPT Pipe Thread
Pipe Thread Male ASA B 2.1
Female thread: R / NPT / BSP / G
Tapering

ODF Outside Diameter Solder Given dimension is outside tube diameter.


Female Female Tube has to be pushed into odf connection.
Given dimension is outside tube diameter.
ODM Outside Diameter Solder
Expanded tube can be pushed onto odm connection or tube can be connected
Male Male
through a sleeve with the odm connection.

301 GPC-EN-2024 CONTROLS COMPONENTS


CE per pressure equipment directive 14/68/EU

Conformity
Fluid Volume TS PS Hazard
Product Assessment Marking
Group (Liter) (°C) (bar) Category
Module
Filter Driers

ADK-03 / 05 / 08 / 16… I + II 0.1 ... 0.38 45 SEP - HP & UL

ADK-30 / 41 / 75… I + II 0.4 ... 0.65 45 SEP - HP & UL

FDB-03 / 05 / 08 / 16… I + II 0.1 ... 0.38 45 SEP - HP & UL


-40 ... +65
FDB-30 / 41… I + II 0.45 ... 0.5 45 SEP - HP & UL

BFK-05 / 08 / 16… I + II 0.18 ... 0.32 45 SEP - HP & UL

BFK-30… I + II 0.4 45 SEP - HP & UL

FDS-24… II 1.0 SEP - HP & UL

ADKS-Plus-48… II 2.1 I A CE & UL


-10 ... +65 34.5
ADKS-Plus-96… II 3.8 I A CE & UL
(-45 ... -10) (25.9)
ADKS-Plus-144… II 5.4 I A CE & UL

ADKS-Plus-192… II 7.0 II A2 CE0036 & UL


-10...+65 46
FDH-48.../96... II I A CE & UL
(-45...-10) (25,9)
ASD/ASF-28.../35…/ 45… I + II <1.0 SEP - HP & UL
-45 ... +50 27.5
ASD/ASF50…/75… I + II <1.4 I A HP & UL

BTAS-2… II 0.42 SEP - HP & UL

BTAS-3… II 1.1 SEP - HP & UL


-45 ... +50 24
BTAS-4… II 1.97 SEP - HP & UL

BTAS-5… II 3.19 I A CE & UL

Oil Management / Components

OSH-404 II 2 I A CE & UL

OSH-405 II 2.4 I A CE & UL

OSH-407 II 2.8 I A CE & UL

OSH-409 II 3 I A CE & UL

OSH-411 / -413 II 3.6 I A CE & UL

OST-404 II 1.8 I A CE & UL

OST-405 II 2.6 I A CE & UL

OSH-407 II 3.2 I A CE & UL

OST-409 / -411 / -413 II 3.8 I A CE & UL

OSH-611 II 6.5 II A2 CE0036 & UL

OSH-613 / -617 II 7.9 -10 ... +150 31 II A2 CE0036 & UL

OSB-613 /-617 II 7.8 II A2 CE0036 & UL

OSH-404-L I 2.0 II A2 CE0036 & UL

OSH-405-L I 2.4 II A2 CE0036 & UL

OSH-407-L I 2.8 II A2 CE0036 & UL

OSH-409-L I 3.0 II A2 CE0036 & UL

OSH-411 / -413-L I 3.6 II A2 CE0036 & UL

OST-404-L I 1.8 II A2 CE0036 & UL

OST-405-L I 2.6 II A2 CE0036 & UL

OSH-407-L I 3.2 II A2 CE0036 & UL

OST-409 / -411 / -413-L I 3.8 II A2 CE0036 & UL

GPC-EN-2024 CONTROLS COMPONENTS 302


CE per pressure equipment directive 14/68/EU

Conformity
Fluid Volume TS PS Hazard
Product Assessment Marking
Group (Liter) (°C) (bar) Category
Module
Suction Accumulators
A08-304 II 0.9 SEP - HP & UL
A10-305 II 1.1 SEP - HP & UL
A12-305 / -306 II 1.3 SEP - HP & UL
A14-305 / -306 II 1.6 SEP - HP & UL
A06-404 / -405 II 1.2 SEP - HP & UL
A10-405 / -406 II 2.1 SEP - HP & UL
A09-506 / -507 II 2.7 I A CE & UL
A12-506 / -507 II 3.8 I A CE & UL
A13-507 / -509 II 4.3 I A CE & UL
A17-509 / -511 II 5.4 I A CE & UL
A11-607 II 5.1 I A CE & UL
A13-607 / -609 II 5.8 I A CE & UL
A14-611 II 6.4 I A CE & UL
A17-613 II 7.9 I A CE & UL
A20-613 II 9.4 I A CE & UL
"-10 ... +65 "20.7
A25-613 II 11.6 II A2 CE0036 & UL
(-45 ...-10)" (15.5)"
A08-304-L I 0.9 SEP - HP & UL
A10-305-L I 1.1 SEP - HP & UL
A12-305 / -306-L I 1.3 I A CE & UL
A14-305 / -306-L I 1.6 I A CE & UL
A06-405-L I 1.2 SEP - HP & UL
A10-405 / -406-L I 2.1 I A CE & UL
A09-506 / -507-L I 2.7 II A2 CE0036 & UL
A12-506 / -507-L I 3.8 II A2 CE0036 & UL
A13-507 / -509-L I 4.3 II A2 CE0036 & UL
A17-509 / -511-L I 5.4 II A2 CE0036 & UL
A11-607-L I 5.1 II A2 CE0036 & UL
A13-607 / -609-L I 5.8 II A2 CE0036 & UL
A14-611-L I 6.4 II A2 CE0036 & UL
A17-613-L I 7.9 II A2 CE0036 & UL
A20-613-L I 9.4 II A2 CE0036 & UL
Pressure Switches
PS1-B3…, PSA-B3… I + II 6 IV B, D CE0035 & UL
PS1-S3…, PSA-S3… I + II 6 22 IV B, D CE0035 & UL
PS1-W3…, PSA-W3… I + II 6 IV B, D CE0035 & UL
PS1-B5…, PSA-B5… I + II 6 -50 ... +70 IV B, D CE0035 & UL
PS1-S5…, PSA-S5… I + II 6 32 IV B, D CE0035 & UL
PS1-W5…, PSA-W5… I + II 6 IV B, D CE0035 & UL
All Other PS1 Types I + II 6 22/32 Under LVD, Excluded from PED CE & UL
PS2-B7…, PSB-B7… I + II 6 IV B, D CE0035 & UL
PS2-C7…, PSB-C7… I + II 6 IV B, D CE0035 & UL
PS2-T7…, PSB-T7… I + II 6 22/32 IV B, D CE0035 & UL
PS2-W7…, PSB-W7… I + II 6 IV B, D CE0035 & UL
PS2-N7…, PSB-N7… I + II 6 -50 ... +70 IV B, D CE0035 & UL
PS2-C8…, PSB-C8… I + II 6 IV B, D CE0035 & UL
PS2-G8…, PSB-G8… I + II 6 32 IV B, D CE0035 & UL
PS2-S8…, PSB-S8… I + II 6 IV B, D CE0035 & UL
All Other PS2 Types I + II 6 22/32 Under LVD, Excluded from PED CE
PS3-W1... II 6 -40 ... +70 27 IV B, D CE0035 & UL
PS3-B6… II 6 IV B, D CE0035 & UL
-40 ... +150 45
PS3-W6… II 6 IV B, D CE0035 & UL
All Other PS3 Type II 6 -40 ... +70 27/32 Under LVD, Excluded from PED CE
CS3-.8...,CS3-.Q... II 6 -40 ... +70 140 IV B, D CE
CS3-.7...,CS3-.P... II 6 -40 ... +70 90 IV B, D CE0035
PS4-W..., PS4-BL... I + II 6 -30 ... +80 25/41/55/69 IV B, D CE0035
All Other PS4 Type I + II 6 -40...+135 24/41/55/69 Under LVD, Excluded from PED CE
FD113… I 6 Under LVD, Excluded from PED CE & UL
LVD = Low Voltage Directive
303 GPC-EN-2024 CONTROLS COMPONENTS
CE per pressure equipment directive 14/68/EU
Conformity
Fluid DN TS PS Hazard
Product Assessment Marking
Group (mm) (°C) (bar) Category
Module
Fan Speed Controllers
FSY-41… II 6 27 CE
Under LVD,
FSY-42… II 6 -20 ... +70 32 CE
Excluded from PED
FSY-43… II 6 43 CE
Transmitters
PT5N-07M/T I + II 6 27 SEP - CE
PT5N-18M/T I + II 6 48 SEP - CE
-40 ... +135
PT5N-30M/T I + II 6 60 SEP - CE
PT5N-50M/T I + II 6 75 SEP - CE
PT5N-150D I + II 6 -40 ... +135 150 SEP - CE
Thermo™ Expansion Valves and Electrical Control Valves
TI I + II Max. 12 -45 ... +75 45 SEP - -
TIH I + II Max. 16 -40 ... +70 46 SEP - -
TX7 I + II Max. 22 -25 ... +70 46 SEP - -
T-Series with XB / XC Power
I + II Max. 28 46 / 31 SEP - -
Element
L-Series with XB / XC Power
I + II Max. 28 -45 ... +75 46 / 31 SEP - -
Element
935-Series with XB / XC
I + II Max. 28 46 / 31 SEP - -
Power Element
ZZ-Series I + II Max. 28 -100 ... +75 31 SEP - -
EXL/M I + II Max. 6 -30 ... +70 45 SEP - -
EXN I + II Max. 12 -30 ... +70 45 SEP - -
EX2 I + II Max. 12 -40 ... +65 40 SEP - -
CX2 II Max. 12 -40 ... +65 90 SEP - -
EX4/EX5/EX6 I + II Max. 25 60 SEP - -
-50 ... +100
EX7 I + II 35 60 II D1 CE0035
Bi-flow:
EX8 I + II 42 56 II D1 CE0035
-50 ... +80
CV4/CV5/CV6 II Max. 22 -50 ... +100 130 SEP - -

Solenoid Valves
110 RB 2… I + II 6....10 31 SEP - -
200 RB 3/4/6… I + II 10 ... 16 31 SEP - -
200 RH 3-6T4/6T5 I + II 10 ... 16 60 SEP - -
240 RA 8/9/12… I + II 16 ... 28 31 SEP - -
240 RA 16T9 II 28 31 SEP - -
240 RA 16T11 II 35 --40 ... +120 31 I A CE
240 RA 20T11/13/17… II 35 31 I A CE
540 RA 8/9/12/16… II 16 ... 28 31 SEP - -
540 RA 20T11 II 35 28 I A CE
M36-078 I + II 28 35 SEP - -
M36-118 I + II 28 35 SEP - -
Regulators
ACP II 6....10 31 SEP - -
--40 ... +120
CPHE... II 12 ... 28 35 SEP - -
PRE/PRC II 16 ... 35 -30... +80 25 SEP - -
Ball Valves
BVE/BVS/CVE/CVS... I + II ≤ 28 45 / 60 SEP - -
--40 ... +120
BVE/BVS…. II ≥ 35 45 I A CE
Moisture Indicators
MIA I + II ≤ 28 45 SEP - -
CIA I + II ≤ 16 60 SEP - -
--40 ... +100
AMI-1..., AMI-3S7, AMI-S9 II ≤ 28 35 SEP - -
AMI-2..., AMI-3S11 II ≤ 54 35 I A CE

GPC-EN-2024 CONTROLS COMPONENTS 304


305 GPC-EN-2024 CONTROLS COMPONENTS
Controls keyword
Electrical register
Control Valves

Controls keyword register

Series Description Page Series Description Page

110 RB 2-Way Solenoid Valve 230 C

200 RB 2-Way Solenoid Valve 230 CPHE Hot Gas Bypass Regulator 240

200 RH 2-Way Solenoid Valve 230 CSS Compressor Soft Starter 196

240 RA 2-Way Solenoid Valve 230 CS1 Pressure controls 250

540 RA 2-Way Solenoid Valve 230 CS3 Pressure Controls (High Pressure) 254

935 Liquid Injection Valve 223 CV Electronic Control Valve 189


A CX2 Electronic Expansion Valve 181
A08 Suction Accumulators 298 E
ACP Hot Gas Bypass Regulator 239 ESC Coils 229
ADK Filter Drier 270 EX2 Electronic Expansion Valve 180
ADKS-Plus Filter Drier Shell 276 EX4 .. EX8 Electrical Control Valves 182
AMI Moisture/Liquid Indicator 282 Stand-alone Superheat/Economizer
EXD-HP1/2 192
Controller
ASF Suction Line Filter 279
EXD-SH1/2 Superheat Controller for EX/CX Valves 189
ASD Suction Line Filter Drier 279
Economizer Controller for Tandem
B EXD-TEVI 198
Compressors
BFK Bi-Flow Filter Drier 268 EXD-U02 Universal Driver Modules 195
BTAS Suction Line Filter and Filter Drier Shell 280 EXM/EXL Electronic Expansion Valve 178
BVE / BVS, CVE / CVS Ball Valves 301 EXN Electronic Expansion Valve 179

GPC-EN-2024 CONTROLS COMPONENTS 306


Controls keyword register

Series Description Page Series Description Page

F P

FD 113 Differential Pressure Controls 258 PRC Crankcase Pressure Regulator 241

FDB Filter Driers 273 PRE Evaporator Pressure Regulator 241

FDH Filter Drier Shell 277 PS1 Pressure Controls 246

FDS-24 Filter-Drier Shells With Quick-Cap 278 PS2 Dual Pressure Controls 246

FSE Fan Speed Control Module 201 PS3 Pressure Controls 251

FSY Electronic Fan Speed Controller 199 PS4 Pressure Controls 256

L PT5N Pressure Transmitter 197

LW4/5 Level Watch LW4 and LW5 294 T

L-Series Thermo Expansion Valve 221 TI Thermo Expansion Valve 207

M TIH Thermo Expansion Valve 210

M36 3-Way Solenoid Valve 235 T-Series Thermo Expansion Valve 216

MIA / CIA Moisture/Liquid Indicator 282 TS1 Thermostat 261

O TX7 Thermo Expansion Valve 214

OM3 / OM4 / OM5 Oil Level Management System 287 Z

OW4 / OW5 Electronic Oil Level Monitoring 292 ZZ Thermo Expansion Valve 219

OS Oil Separator 296

307 GPC-EN-2024 CONTROLS COMPONENTS


Standard Terms and Conditions Of Sale – Products & Services Copeland Europe GmbH, Copeland Cold Chain Europe GmbH COS_P&S_DEU: EPM effective July-2023

1. DEFINITIONS: removing such defects will be borne by Buyer upon demand. Buyer will always be responsible alone for the completeness and
In these Terms and Conditions of Sale, "Seller" means one of the Copeland companies mentioned in the title; "Buyer" means the correctness of any information provided by it.
person, firm, company or corporation by whom the order is given; "Goods" means the goods (including any Software and
Documentation, as defined in Clause 9) describe din Seller's Acknowledgement of Order form; “Services” means the services described 10.7 Regarding products or Services sourced by Seller from a third party (other than a Seller Affiliate) for resale to Buyer, Seller assigns
in Seller’s Acknowledgement of Order Form; "Contract" means the written agreement (including these Terms and Conditions) made to Buyer all warranty rights against such third party. In addition, Seller remains obliged to assume the warranty set forth the preceding
between Buyer and Seller for the supply of the Goods and/or provision of Services; "Contract Price" means the price payable to Seller clauses towards Buyer, however, only under the restriction that Buyer has beforehand unsuccessfully tried to execute the assigned
by Buyer for the Goods and/or Services and “Seller Affiliate” means an Copeland Group company which is an affiliate within the meaning warranty rights against the third party.
of Section 15 AktG [German Stock Corporation Act].
2. THE CONTRACT: 11. LIABILITY FOR PROPRIETARY RIGHTS INFRINGEMENTS
2.1 All orders must be in writing and are accepted subject to these Terms and Conditions of Sale. No terms or conditions put forward 11.1 Seller warrants that upon passing of the risk no patents or other proprietary rights of third parties exist which may be claimed with
by Buyer and no representations, warranties, guarantees or other statements not contained in Seller's quotation or Acknowledgement respect to the Goods or Services if these are used as intended. Clauses 10.2 to 10.5 and 10.7 shall apply correspondingly.
of Order nor otherwise expressly agreed in writing by Seller shall be binding on Seller. 11.2 Seller's liability shall be excluded where a third party patent or proprietary right is infringed because Seller has adhered to a design
2.2 The Contract shall become effective only upon the date of acceptance of Buyer's order on Seller's Acknowledgement of Order provided by Buyer or has complied with an instruction given by Buyer, or because the Goods are used in a manner, for a purpose, in
form. If the details of the Goods or Services described in Seller's quotation differ from those set out in the Acknowledgement of Order a country, or in connection with other goods or services, without this having been communicated to Seller before execution of the
Form the latter shall apply. Contract.
2.3 No alteration or variation to the Contract shall apply unless agreed in writing by both parties. However, Seller reserves the right to 11.3 During the period of Seller's warranty, Buyer has the obligation to inform Seller in writing as promptly as possible in the event that
effect minor modifications and/or improvements to the Goods before delivery provided that the performance of the Goods is not a third party claims any patent or other proprietary right or asserts any claims in or out of court with respect to the Goods or Services.
adversely affected and that neither the Contract Price nor the delivery date is affected. Before recognising any claim advanced by a third party in or out of court, Buyer shall give Seller the opportunity to comment. At its
request, Seller shall be given the authority to handle the negotiations or legal dispute with such third party at its own cost and
3. VALIDITY OF QUOTATION AND PRICES: responsibility. Buyer shall be liable to Seller for any damage sustained by it as a result of a culpable violation of said obligations.
3.1 Unless previously withdrawn, Seller's quotation is open for acceptance within the period stated therein or, when no period is so 11.4 Buyer warrants that the use of a design provided by it or compliance with an instruction given by it will not lead to Seller infringing
stated, within thirty days after its date. any patents or other proprietary rights when performing its contractual obligations. Buyer agrees to indemnify and hold Seller harmless
3.2 Prices are firm for delivery within the period stated in Seller's quotation and are exclusive of (a) Value Added Tax and (b) any against any reasonable cost and damages incurred by Seller as a result of Buyer's breach of this warranty.
similar and other taxes, duties, levies or other like charges arising outside Germany in connection with the performance of the Contract.
3.3 Prices (a) are for Goods delivered EXW (Ex works) Seller’s shipping point, exclusive of freight, insurance and handling and (b) 12. DAMAGES
unless otherwise stated in the Seller's quotation, are exclusive of packing. If the Goods are to be packed, packing materials are non- 12.1 Seller shall be liable to Buyer only for damage caused with intent or gross negligence. In the event of breach of material contractual
returnable. obligations, Seller shall, however, be liable for each fault of its personnel (statutory representatives, executive employees and other
persons employed in the performance of its obligations) causing damage.
4. PAYMENT: 12.2 Except in case of intentional causation of damage by personnel of Seller or causation of damage with gross negligence by
4.1 Payment shall be made: (a) in full without set-off, counterclaim or withholding of any kind (save where and to the extent that this statutory representatives or executive employees of Seller, Seller shall not be liable for compensation for indirect damage and, in
cannot by law be excluded); and (b) in the currency of Seller's quotation within thirty days of receipt of invoice unless otherwise specified particular, Seller shall not be liable for compensation for loss of profit, unless such damage is covered by the protective purpose of a
by Seller’s Finance Department. Goods will be invoiced at any time after their readiness for despatch has been notified to Buyer. warranty explicitly assumed.
Services will be invoiced monthly in arrears or, if earlier, upon completion. Without prejudice to Seller's other rights, Seller reserves the 12.3 Except in case of intentional causation of damage by personnel of Seller or causation of damage with gross negligence by
right to: (i) charge interest on any overdue sums at 8% above the base lending rate of Section 247 BGB (German Civil Code) during statutory representatives or executive employees of Seller, the liability of Seller shall, in each case, be limited in terms of amount to
the period of delay; (ii) suspend performance of the Contract (including withholding shipment) in the event that Buyer fails or in Seller’s the damage which is typically foreseeable in the time of conclusion of the contract.
reasonable opinion it appears that Buyer is likely to fail to make payment when due under the Contract or any other contract; and (iii) 12.4 Claims to damages which result from the violation of another's life, body or health, from the violation of a guaranty given by Seller
under the same conditions require reasonable security for payment. expressly in writing as well as damage claims under the Product Liability Act shall remain unaffected.
4.2 Customer may set off counterclaims only if recognised or non-appealable. A right of retention may be exercised by Customer only
if as it concerns the same contractual relationship. 13. STATUTORY AND OTHER REGULATIONS:
13.1 If Seller's obligations under the Contract shall be increased or reduced by reason of the making or amendment after the date of
5. DELIVERY PERIOD: Seller's quotation of any law or any order, regulation or bye-law having the force of law that shall affect the performance of Seller's
5.1 Unless otherwise stated in Seller's quotation, all periods stated for delivery or completion run from the Effective Date and are to be obligations under the Contract, the Contract Price and delivery period shall be adjusted accordingly and/or performance of the Contract
treated as estimates only not involving any contractual obligations. suspended or terminated, as appropriate. A price adjustment shall not be implemented if the delivery is to be carried out within 4
5.2 If Seller is delayed in or prevented from performing any of its obligations under the Contract due to the acts or omissions of Buyer months after the closing of the Contract.
or its agents (including but not limited to failure to provide specifications and/or fully dimensioned working drawings and/or such other 13.2 Except to the extent otherwise required by applicable law, Seller shall have no responsibility for the collection, treatment, recovery
information as Seller reasonably requires to proceed expeditiously with its obligations under the Contract), the delivery/completion or disposal of (i) the Goods or any part thereof when they are deemed by law to be 'waste' or (ii) any items for which the Goods or any
period and the Contract Price shall both be adjusted accordingly. part thereof are replacements. If Seller is required by applicable law, including waste electrical and electronic equipment legislation,
5.3 If delivery is delayed due to any act or omission of Buyer, or if having been notified that the Goods are ready for despatch, Buyer European Directive 2002/96/EC (WEEE) and related legislation in EU Member States, to dispose of 'waste' Goods or any part thereof,
fails to take delivery or provide adequate shipping instructions, Seller shall be entitled to place the Goods into a suitable store at Buyer's Buyer shall, unless prohibited by applicable law, pay Seller, in addition to the Contract Price, either (i) Seller's standard charge for
expense. Upon placing the Goods into the store, delivery shall be deemed to be complete, risk in the Goods shall pass to Buyer and disposing of such Goods or (ii) if Seller does not have such a standard charge, Seller's costs (including all handling, transportation and
Buyer shall pay Seller accordingly. disposal costs and a reasonable mark-up for overhead) incurred in disposing of such Goods.
13.3 Buyer's personnel shall, whilst on Seller's premises, comply with Seller's applicable site regulations and Seller's reasonable
6. FORCE MAJEURE:
instructions, including but not limited to those relating to safety, security and electrostatic discharge.
6.1 The Contract (other than Buyer's obligation to pay all sums due to Seller in accordance with the Contract) shall be suspended,
without liability, in the event and to the extent that its performance is prevented or delayed due to any circumstance beyond the 14. COMPLIANCE WITH LAWS
reasonable control of the party affected, including but not limited to: Act of God, war, armed conflict or terrorist attack, riot, fire, explosion, Buyer agrees that all applicable import, export control and sanctions laws, regulations, orders and requirements, as they may be
accident, flood, sabotage; governmental decisions or actions (including but not limited to prohibition of exports or re-exports or the failure amended from time to time, including without limitation those of the United States, the European Union and the jurisdictions in which
to grant or the revocation of applicable export licenses), or labour trouble, strike, lockout or injunction. Seller shall have no obligation to Seller and Buyer are established or from which items may be supplied, and the requirements of any licenses, authorisations, general
supply hardware, software or technology or to provide services in the absence of government permits or fulfilment of statutory conditions licences or licence exceptions relating thereto will apply to its receipt and use of hardware, software, services and technology. In no
of exemption from such permits within the framework of import and export control (in particular, according to the regulations applicable event shall Buyer use, transfer, release, export or re-export any such hardware, software or technology in violation of such applicable
in the United States, the European Union and the jurisdiction in which Seller has its registered office or from which components of the laws, regulations, orders or requirements or the requirements of any licences, authorisations or licence exceptions relating thereto.
Goods are supplied) and the underlying circumstances could not be foreseen by Seller and are outside of Seller’s sphere of influence. Buyer agrees furthermore that it shall not engage in any activity that would expose the Seller or any of its affiliates to a risk of penalties
In the event of revocation of issued government permits or in the event of a change in the applicable statutory import and export control under laws and regulations of any relevant jurisdiction prohibiting improper payments, including but not limited to bribes, to officials of
regulations such that Seller is prevented from fulfilling the contract, Seller is discharged from the contractual obligation without any any government or of any agency, instrumentality or political subdivision thereof, to political parties or political party officials or
liability of Seller. candidates for public office, or to any employee of any customer or supplier. Buyer agrees to comply with all appropriate legal, ethical
6.2 If either party is delayed or prevented from performance of its obligations by reason of this Clause for more than 180 consecutive and compliance requirements.
calendar days, either party may terminate the then unperformed portion of the Contract by notice in writing given to the other party,
15. DEFAULT, INSOLVENCY AND CANCELLATION:
without liability provided that Buyer shall be obliged to pay the reasonable cost and expense of any work in progress and to pay for all
Seller shall be entitled, without prejudice to any other rights it may have, to cancel the Contract forthwith, wholly or partly, by notice in
Goods delivered and Services performed as at the date of termination.
writing to Buyer, if Buyer is in default of any of its obligations under the Contract and fails, within 30 (thirty) days of the date of Seller's
7. INSPECTION, TESTING, AND CALIBRATION: notification in writing of the existence of the default, either to rectify such default if it is reasonably capable of being rectified within such
7.1 Goods will be inspected by Seller or manufacturer and, where practicable, submitted to Seller's or manufacturer's standard tests period or, if the default is not reasonably capable of being rectified within such period, to take action to remedy the default.
before despatch. Any additional tests or inspection (including inspection by Buyer or its representative, or tests in the presence of Buyer
16. SUPPLEMENTARY TERMS AND CONDITIONS:
or its representative and/or calibration) or the supply of test certificates and/or detailed test results shall be subject to Seller's prior written
If the Goods comprise or include a control system, Seller's Supplementary Terms and Conditions Applicable to the Supply of Control
agreement and Seller reserves the right to charge therefor; if Buyer or its representative fails to attend such tests, inspection and/or
Systems and Related Services shall apply to the control system and related services only. Such Supplementary Terms and Conditions
calibration after seven days' notice that the Goods are ready therefor, the tests, inspection and/or calibration will proceed and shall be
shall take precedence over these Standard Terms and Conditions of Sale; copies are available from Seller upon request.
deemed to have been made in the presence of Buyer or its representative and the Seller's statement that the Goods have passed such
testing and/or inspection and/or have been calibrated shall be conclusive. 17. Data protection
7.2 Buyer’s warranty rights are subject to Buyer’s proper compliance with Buyer’s inspection and complaint obligations set forth in 17.1 Each party to this Contract is responsible for compliance with the relevant data protection provisions, in particular for
Section 377 of the German Commercial Code (HGB). the admissibility of data processing and for safeguarding the data subjects' statutory rights, stipulated by the data protection
Law(s) (“Law is applicable law, including statutory rules and regulations, decrees, directives, orders, by-laws and ordinances
8. DELIVERY, RISK & TITLE:
having the force of law"). Each party affirms that any processing of personal data ((i.e. any information that relates to an
8.1 Unless otherwise expressly stated in the Contract, the Goods will be delivered Carriage and Insurance Paid To (CIP) the
identified or identifiable living individual) in accordance with Regulation (EU) 2016/679 of the European Parliament and of
destination named in the Contract; freight, packing and handling will be charged at Seller’s standard rates. Risk of loss of or damage to
the Council of 27 April 2016 under this Contract shall not violate any provisions of the applicable local, state, federal, and
the Goods shall pass to Buyer upon delivery as aforesaid and Buyer shall be responsible for insurance of the Goods after risk has so
foreign data privacy and sovereignty laws, regulations, rules and restrictions as the same relate to the collection, movement,
passed. Alternatively, if it is expressly stated in the Contract that Seller is responsible for the insurance of the Goods after their
and use of personal data provided by either Party or generated by the Goods or provision of Services.
delivery to the carrier, such insurance will be charged at Seller’s standard rates. "Ex-works", "FCA", “CIP” and any other delivery terms
17.2 Seller shall, to the extent it is processing Buyer’s personal data:
used in the Contract shall be defined in accordance with the latest version of Incoterms. - not access or use Buyer’s personal data, except as necessary for the fulfillment of the Contract. Seller will process
9. DOCUMENTATION AND SOFTWARE: Buyer’s personal data in accordance with this Contract and take the appropriate technical and organizational measures
9.1 Title to and ownership of the copyrights in software and/or firmware incorporated into or provided for use with the Goods to protect Buyer’s personal data against accidental or unauthorized loss, disclosure or access.
("Software") and documentation supplied with the Goods ("Documentation") shall remain with the relevant Seller Affiliate (or such other - co-operate and provide reasonable assistance to Buyer in connection with Buyer's compliance with data protection
party as may have supplied the Software and/or Documentation to Seller) and is not transferred hereby to Buyer. Law(s) insofar as they relate to the scope of the Contract and to the extent Seller has the information available. This
9.2 Except as otherwise provided herein, Buyer is hereby granted a non-exclusive, royalty-free licence to use the Software and includes: (i) responding to requests from individuals or authorities, (ii) notifying data breaches to affected individuals or
Documentation in conjunction with the Goods, provided that and for so long as the Software and Documentation are not copied (unless authorities; (iii) carrying out data protection impact assessments.
expressly authorised by applicable law) and Buyer holds the Software and Documentation in strict confidence and does not disclose - use and share Buyer personal data in accordance with applicable data protection Law(s), as necessary for the purpose
them to others, or permit others to have access to them (other than Seller's standard operating and maintenance manuals). Buyer may of this Contract by sharing contact information with agents and sales representatives to fulfil this Contract.
transfer the foregoing licence to another party which purchases, rents or leases the Goods, provided the other party accepts and agrees - collect, store and use Buyer personal data for product registration and technical support purposes.
in writing to be bound by the conditions of this Clause 9. 17.3 Both Parties agree to sign European Standard Contractual Clauses if any Personal Data is to be transferred to a
9.3 Notwithstanding Sub-clause 9.2, Buyer’s use of certain Software, (as specified by Seller and including but not limited to control country outside the EU/EEA.
system and AMS Software) shall be governed exclusively by the applicable Seller Affiliate or third party licence agreement. 17.4 With regard to the collection processing and use of personal data (if any) by Seller, please refer to Seller’s Privacy
9.4 Seller and Seller Affiliates shall retain ownership of all inventions, designs and processes made or evolved by them and save as Notice, which is available at https://www.copeland.com/en-gb/privacy-notice.
set out in this Clause 9 no rights in intellectual property are hereby granted.
10. LIABILITY FOR DEFECTS OF QUALITY 18. MISCELLANEOUS:
10.1 Seller warrants that upon passing of the risk the Goods and Services will have the quality agreed upon. Unless 18.1 No waiver by either party with respect to any breach or default or of any right or remedy and no course of dealing, shall be
otherwise agreed, the quality agreed upon shall meet Seller's specifications as valid and published at the time of the order deemed to constitute a continuing waiver of any other breach or default or of any other right or remedy, unless such waiver be
confirmation. expressed in writing and signed by the party to be bound.
10.2 If, upon passing of the risk, the Goods or Services do not have the quality agreed upon, Seller warrants to provide 18.2 If any clause, sub-clause or other provision of the Contract is invalid or unenforceable, this shall not affect the validity of the
subsequent performance by either, at its option, repairing or replacing the concerned parts (subsequent rectification) or by remainder of the Contract. Should one of the clauses be invalid or unenforceable, the parties obligate themselves to replace the invalid
replacing the Goods or Services by such Goods or Services which are free from defects (subsequent delivery). or unenforceable clause by such a clause which comes closest to the intended economic purpose of the invalid clause.
10.3 Seller may rectify any defect several times and may decide at its discretion to change from rectification to subsequent 18.3 Buyer shall not be entitled to assign its rights or obligations hereunder without the prior written consent of Seller.
delivery. Seller shall be responsible for all costs incurred in connection with its subsequent performance, especially the 18.4 Seller enters into the Contract as principal. Buyer agrees to look only to Seller for due performance of the Contract.
transport, shipping, labour and material cost, unless such costs are incurred as a result of the Goods being taken to a place 18.5 GOODS AND SERVICES PROVIDED HEREUNDER ARE NOT SOLD OR INTENDED FOR USE IN ANY NUCLEAR OR
other than the place of performance. NUCLEAR RELATED APPLICATIONS. Buyer (i) accepts Goods and Services in accordance with the foregoing restriction, (ii) agrees
10.4 Buyer may set a reasonable period of at least four (4) weeks to Seller for him to provide subsequent performance and, to communicate such restriction in writing to any and all subsequent purchasers or users and (iii) agrees to defend, indemnify and hold
if subsequent performance fails during such period, may demand reduction of the Contract Price after expiry of that period harmless Seller and Seller’s Affiliates from any and all claims, losses, liabilities, suits, judgements and damages, including incidental
or, unless the defect is insignificant, may rescind the Contract. Damages may only be claimed in line with Clause 14. and consequential damages, arising from use of Goods and Services in any nuclear or nuclear related applications, whether the cause
10.5 Any claims and rights based on defects will become time-barred, except in the case of intent, after expiry of twelve (12) of action be based in tort, contract or otherwise, including allegations that the Seller's liability is based on negligence or strict liability.
months since taking into operation of the Goods, however no later than eighteen (18) months since delivery. Claims to 18.6 The Contract shall in all respects be construed in accordance with the laws of the Federal Republic of Germany excluding,
damages based on defects will become time-barred after expiry of the statutory period if they result from a violation of however, any effect on such laws of the 1980 Vienna Convention on Contracts for the International Sale of Goods, and to the fullest
another's life, health or body, or from Seller's gross negligence. extent permitted by law, shall be without regard to any conflict of laws or rules which might apply the laws of any other jurisdiction. All
10.6 Seller assumes no warranty for normal wear and tear, material provided by Buyer, processing of the Goods made by disputes arising out of the Contract shall be subject to the exclusive jurisdiction of the Berlin courts. However, Seller is entitled to sue
Buyer, damage due to improper storage, installation or operation or due to inadequate maintenance, or damage resulting Buyer in the court of Buyer’s residence as well.
from any modification or repair not approved beforehand by Seller in writing. Seller will not be liable where any non- 18.7 The headings to the Clauses and paragraphs of the Contract are for guidance only and shall not affect the interpretation thereof.
authorised software or non-authorised spare or replacement parts are used. Any costs incurred by Seller for examining and 18.8 All notices and claims in connection with the Contract must be in writing.

Copeland Cold Chain Europe GmbH Copeland Europe GmbH


Registered Office: Registered Office:
Amtsgericht Berlin-Charlottenburg, HRB 81171 Amtsgericht Berlin-Charlottenburg, HRB 877B

308
Notes

309
BENELUX UK & IRELAND
Josephinastraat 19 Tel: +44 1189 83 80 00
NL-6462 EL Kerkrade Fax: +44 1189 83 80 01
Tel: +31 45 535 06 73 [email protected]
Fax: +31 45 535 06 71
[email protected]
SWEDEN, DENMARK, NORWAY & FINLAND
GERMANY, AUSTRIA & SWITZERLAND Pascalstr. 65
Theo-Mack-Str. 3 DE-52076 Aachen
DE-63477 Maintal Tel: +49 2408 929 0
Tel: +49 6109 605 90 Fax: +49 2408 929 525
[email protected] [email protected]

EASTERN EUROPE & TURKEY


FRANCE, GREECE & MAGHREB Pascalstr. 65
8, Allée du Moulin Berger DE-52076 Aachen
FR-69134 Ecully Cédex, Tel: +49 2408 929 0
Technoparc - CS 90220 Fax: +49 2408 929 525
Tel: +33 4 78 66 85 70 [email protected]
Fax: +33 4 78 66 85 71
[email protected]
POLAND
ITALY ul. Konstruktorska 13
Via Ramazzotti, 26 PL-02673 Warsaw
IT-21047 Saronno (VA) Tel: +48 22 458 92 05
Tel: + 39 02 9713 8060 Fax: +48 22 458 92 55
[email protected] [email protected]

SPAIN & PORTUGAL BALKAN


C/ Pujades, 51-55 Box 53 Selska cesta 93
ES-08005 Barcelona HR-10 000 Zagreb
Tel: +34 93 412 37 52 Tel: +385 1 560 38 75
[email protected] Fax: +385 1 560 38 79
[email protected]
CZECH REPUBLIC
Hajkova 22 MIDDLE EAST & AFRICA
CZ - 133 00 Prague PO Box 26382
Tel: +420 733 161 651 Jebel Ali Free Zone - South, Dubai - UAE
Fax: +420 271 035 655 Tel: +971 4 811 81 00
[email protected] Fax: +971 4 886 54 65
[email protected]
ROMANIA & BULGARIA
Str. Alexandru Vaida Voevod Nr. 53B, Et. 5
400436, Cluj-Napoca, Romania
Tel: +40 364 821 680
[email protected]

ASIA PACIFIC
Suite 2503-8, 25/F., Exchange Tower
33 Wang Chiu Road, Kowloon Bay
Kowloon , Hong Kong
Tel: +852 2866 3108
Fax: +852 2520 6227

For more details, see copeland.com/en-gb


Copeland Europe GmbH
Pascalstrasse 65 - 52076 Aachen, Germany
Tel. +49 (0) 2408 929 0 - Fax: +49 (0) 2408 929 570 – Internet: copeland.com/en-gb
GPC-2024-EN

The Copeland logo is a trademark and service mark of Copeland LP or one of its affiliates. Copeland Europe
GmbH shall not be liable for errors in the stated capacities, dimensions, etc., as well as typographic errors.
Products, specifications, assumptions, designs and technical data contained in this document are subject to
modification by us without prior notice. Illustrations are not binding. ©2024 Copeland LP. All rights reserved.

You might also like