CALIBRATION CERTIFICATE
Format No.: SCCPL-QF-7.8.1               Certificate No.: SCCPLCC20241223-033 ULR No.: CC328724000017253F
Group: Dimension (Basic Measuring Instruments, Gauge etc.)    Discipline: Mechanical
Customer’s Name & Address                                      Page No.: 1 of 2 Calibration Performed: At Lab
M/s. Vaishnavi Laminates & Wood Works Pvt. Ltd.                Date of Receipt: 23-12-2024
Survey No. 211, Ghoghli Tampa Panchmukhi                       Service Request No.: SCCPLSRN20241223-002
Hanuman Mandir, Klmeshwar Khapari, Nagpur                      Certificate Issue Date: 26-12-2024
                                                               Date of Calibration: 25-12-2024
                                                               Next Due Date (Suggested by Customer): 24-12-2025
Equipment Description (UUC) & Identification
Name of the Instrument: Feeler Gauge                           Make: Vetpex
                                                               Model: ------
Range: 0.025 to 0.635 mm                                       Sr. No.: ------
Least Count: ------                                            I.D. No.: FG-01
Condition of Instrument: Ok                                    Location: ------
Master Equipment Used
Sr. No. Instrument’s Name       Range & I.D. No.      Calibration Agency          Calibration Certificate No. Valid Up to
   1      Digital External       0 To 25 mm &               SCCPL                  SCCPLCC20240113-004        14-01-2025
           Micrometer           SCCPL/CAL/016
Environmental Conditions                            Calibration Procedure              Calibration Reference Standard
Temperature: 20 ± 2 ⁰C, Humidity: 50 ± 10 %RH         SCCPL 03 SOP 005                             IS 3179
                                               CALIBRATION RESULTS
Sr. No.     Nominal Value of          Observed Ref. Standard                 Error                Expanded Uncertainty
              UUC (mm)                     Value (mm)                        (mm)                       (±) mm
   1            0.038                         0.040                         -0.002                      0.0022
   2            0.051                         0.052                         -0.001                      0.0022
   3            0.064                         0.065                         -0.001                      0.0022
   4            0.076                         0.078                         -0.002                      0.0022
   5            0.102                         0.104                         -0.002                      0.0022
   6            0.127                         0.125                         0.002                       0.0022
   7            0.152                         0.151                         0.001                       0.0022
   8            0.178                         0.181                         -0.003                      0.0022
   9            0.203                         0.208                         -0.005                      0.0022
  10            0.229                         0.233                         -0.004                      0.0022
  11            0.254                         0.257                         -0.003                      0.0022
  12            0.279                         0.279                         -0.004                      0.0022
  13            0.305                         0.308                         -0.003                      0.0022
       Calibrated By                                                                           Reviewed/Approved By
          Hemraj                                                                                     L.M. Mahato
   Calibration Engineer                                                                     Chief Executive Officer (CEO)
                         CALIBRATION CERTIFICATE
 Format No.: SCCPL-QF-7.8.1               Certificate No.: SCCPLCC20241223-033 ULR No.: CC328724000017253F
 Group: Dimension (Basic Measuring Instruments, Gauge etc.)    Discipline: Mechanical
 Customer’s Name & Address                                                                 Page No.: 2 of 2 Calibration Performed: At Lab
 M/s. Vaishnavi Laminates & Wood Works Pvt. Ltd.                                           Date of Receipt: 23-12-2024
 Survey No. 211, Ghoghli Tampa Panchmukhi                                                  Service Request No.: SCCPLSRN20241223-002
 Hanuman Mandir, Klmeshwar Khapari, Nagpur                                                 Certificate Issue Date: 26-12-2024
                                                                                           Date of Calibration: 25-12-2024
                                                                                           Next Due Date (Suggested by Customer): 24-12-2025
                                                                   CALIBRATION RESULTS
Sr. No.            Nominal Value of                     Observed Ref. Standard                                Error                     Expanded Uncertainty
                     UUC (mm)                                Value (mm)                                       (mm)                            (±) mm
   14                  0.330                                    0.333                                        -0.003                           0.0022
   15                  0.356                                    0.352                                        0.004                            0.0022
   16                  0.381                                    0.383                                        -0.002                           0.0022
   17                  0.406                                    0.408                                        -0.002                           0.0022
   18                  0.432                                    0.435                                        -0.003                           0.0022
   19                  0.457                                    0.459                                        -0.002                           0.0022
   20                  0.483                                    0.481                                        0.002                            0.0022
   21                  0.508                                    0.505                                        0.003                            0.0022
   22                  0.533                                    0.539                                        -0.006                           0.0022
   23                  0.559                                    0.554                                        0.005                            0.0022
   24                  0.584                                    0.586                                        -0.002                           0.0022
   25                  0.610                                    0.615                                        -0.005                           0.0022
   26                  0.635                                    0.641                                        -0.006                           0.0022
                                                                  ***End of Certificate***
         Calibrated By                                                                                                             Reviewed/Approved By
            Hemraj                                                                                                                       L.M. Mahato
     Calibration Engineer                                                                                                       Chief Executive Officer (CEO)
Note: - 1. The calibration results reported in this certificate are valid at the time of and stated condition of measurement.
       2. This report is not to be reproducing wholly or in part and cannot be used as evidence in the Court of Law and should not be used in any advertising media
       without our special permission in writing.
       3. Total liability of our Organization is limited to the invoiced amount.
       4. Calibration Certificate without signature are not valid.
       5. All our certificates are metrological traceable.
       6. The results relate only to the item calibrated.
       7. UUC: Unit Under Calibration.
       8. Expanded Uncertainty of measurement expressed at approximately the 95 % level of confidence, using a coverage factor of k = 2.
       9. Scan this QR code to download our NABL Accreditation Scope & Certificate.