0% found this document useful (0 votes)
15 views107 pages

150 - 12 Farenda, Khuniyaon Block, Siddharth Nagar District, U.P.

The document outlines the design and implementation of a 150KL Elevated Storage Reservoir (ESR) at Farenda, Khuniyaon Block, Siddharth Nagar District, Uttar Pradesh, including structural analysis, design calculations, and compliance with Indian Standards. It details the materials, site conditions, load calculations, and structural design considerations for the water supply project. The project is managed by the State Water & Sanitation Mission and involves various components such as tube wells, water treatment plants, and distribution networks.

Uploaded by

ak2sudhir693
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views107 pages

150 - 12 Farenda, Khuniyaon Block, Siddharth Nagar District, U.P.

The document outlines the design and implementation of a 150KL Elevated Storage Reservoir (ESR) at Farenda, Khuniyaon Block, Siddharth Nagar District, Uttar Pradesh, including structural analysis, design calculations, and compliance with Indian Standards. It details the materials, site conditions, load calculations, and structural design considerations for the water supply project. The project is managed by the State Water & Sanitation Mission and involves various components such as tube wells, water treatment plants, and distribution networks.

Uploaded by

ak2sudhir693
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 107

FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P.

150_12

PROJECT

IMPLEMENTATION OF VARIOUS RURAL WATER SUPPLY PROJECTS COMPRISING OF TUBE


WELL/LNTAKE WELL, WTP, RISING/ PRESSURE MAINS, CWRS, OVERHEAD TANKS,
DISTRIBUTION PIPE NETWORKS, INDIVIDUAL HOUSE CONNECTIONS, PUBLIC STAND POSTS
ETC. LOCATED IN THE STATE OF UTTAR PRADESH.
EXECUTIVE DIRECTOR, STATE WATER & SANITATION MISSION,
CLIENT NAMAMI GANGE & RURAL WATER SUPPLY DEPARTMENT ,
LUCKNOW, UTTAR PRADESH

VSAIPPL‐SCL JV
CONTRACTOR
Hyderabad

CONSULTANT
MATSHUI ENGINEERING SERVICES PVT. LTD.

DESIGN CALCULATION OF ESR 150 KL, 12 M STAGING AT GP‐


TITLE FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P.

DOCUMENT VSA/JJM/SIDDHARTH NAGAR/OHT/05

R0 Submitted for Approval


DATE REV DESCRIPTION / REVISIONS

Page 1 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

TABLE OF CONTENT

1. General
2. Site Conditions
3. Materials
4. Structural Analysis
5. Structural Design
6. Load Calculations
7. Design of Tank
8. Design of Staging
9. Design of Foundation

Page 2 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

1 GENERAL

1.1 Scope

This document covers the analysis and design of 150KL ESR at FARENDA,
KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT with 12 m staging height.
This document is prepared on the basis of Contract document.

1.2 Codes & Standards

All design work will be based on Indian Standards (IS) codes (latest revisions), with
amendments, if any, as on date. Apart from these codes, specific design guidelines laid in the
contract documents are followed.

The design is carried out in conformity with following IS code latest editions. IS: 456 -2000
– Code of practice for plain and reinforced concrete

 IS: 3370 (Part-1)-2009 – Concrete Structures for Storage of Liquids –Code of Practice
Part-1 General Requirements
 IS: 3370 (Part-2)-2009 – Concrete Structures for Storage of Liquids –Code of Practice
Part-2 Reinforced Concrete Structures
 IS: 3370 (Part-4)-1967 – Concrete Structures for Storage of Liquids –Code of Practice
Part-4 Design Tables
 IS: 875 -1987 - Code of practice for Design Loads for Building and Structures. (Part-1
to 5)
 IS: 1893-2002 - Criteria for Earthquake Resistant design of structures. Part-1 General
Provisions of buildings
 IS: 1893-2014 - Criteria for Earthquake Resistant design of structures. Part-2 Liquid
Retaining Tanks
 IS 800-2007 - Code of Practice for general construction in steel.
 IS 13920:1993 – Ductile detailing of reinforced concrete structures subjected to seismic
force – code of practice.
 SP: 16 – Design Aids for Reinforced Concrete.
 SP: 34 - Handbook on Concrete Reinforcement and Detailing.

Page 3 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

 IS 11682:1985 – Criteria for Design of RCC Staging for Overhead Water Tanks.

1.3 Units of measurements

All units used in the analysis and designs are in SI system unless noted otherwise.

1.4 Computer Program /Software

STAAD-PRO software is used for analysis and in-house Excel spread sheets are used for
design.

2 SITE CONDITIONS

2.1 Design Ground Elevation

Finished Ground level of the respective tank area is taken as EL (+) 0.300 m level

2.2 Soil Data

The safe bearing capacity of foundation is taken as 80 kN/m2 founded at a minimum depth

of 2 m below natural ground level/finished ground level.

3 MATERIALS

3.1 Cement

Ordinary Portland cement of 43 grade or Portland Pozzolana Cement/Portland Slag Cement of


53 grade conforming to latest IS codes and minimum cement content for RCC M30 grade will
be 320 kg/m3 & RCC M25/M20 grade will be 300 kg/m3.

3.2 Plain cement concrete

The Plain cement concrete under all RCC foundation will be of grade M10 of 100 mm thick

and 100 mm projection.

3.3 Reinforced Concrete

Minimum grade of structural concrete for Water retaining structures will be M30 and All other
structures will be M25 except compound wall, valve chambers & cable trench for which it will
be M20.

Page 4 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

3.4 Reinforcement bars

Reinforcement bars will be High yield strength deformed bars Fe 500 TMT confirming to IS:
1786-2008.

3.5 Unit weight of materials

The following unit weight of material shall be considered for computation of loads. Loads
given in IS: 875 (Part-I) shall be made use of for material not listed below

Sl.No Material Unit weight (kN/m³


1 Reinforced concrete 25
2 Plain cement concrete 24
3 Soil 18
5 Water 10
6 Structural steel 78.5

4 STRUCTURAL ANALYSIS

4.1 Modelling

ESR walls, base slab, & roof slab are modelled as Plate element in STAAD-PRO with staging.
Bottom of columns are considered fixed at foundation level. Foundations are modelled and
designed separately using Nodal loads and moments obtained from STAAD model at bottom
of columns. Staging is modelled with beam element. Stiffness of the staging for seismic base
shear calculation is obtained through a separate model consisting of staging alone.

4.2 Method of Analysis

The structure is analyzed using STAAD-PRO. Walls, Cover Slab, Base Slab & Foundation are
designed using in-house developed Spread sheets. All RCC members like Walls, Roof Slabs &
beams, base slab & beams, submerged Columns, ring beams etc. of the container are designed
as un-cracked sections as per IS: 3370 (Part 2). However, staging columns are designed by
limit state method, Tie beams, plinth beams and foundation is designed using limit state method
as per IS: 456-2000.

4.3 Basic Loads

The ESR is analyzed for following loads

a) Dead load
Self-weight of slab

Page 5 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Roof finish/Water proof treatment = 1.8 kN/m2


b) Live load
On Cover slab and gallery = 1.5 kN/m2
On Staircase = 5.0 kN/m2
c) Wind load
Various design parameters for calculation of wind loads on structures
are determined on the basis of IS: 875 2016 (Part III). Following
parameters has been considered for the wind load calculation.
Basic wind speed = 47 m/sec
Risk coefficient (k1) = 1.0
Terrain category for (k2) factor = category 2
Topography factor (k3) = 1.0 Importance
factor for cyclonic region (k4) = 1.15
d) Seismic load
The seismic analysis of the ESR will be carried out as per IS: 1893
(Part-II) -2014. The design horizontal seismic coefficient Ah for the
structure will be determined using the following parameters
Seismic zone = IV
Zone Factor (Z) = 0.24
Design horizontal seismic coefficient Ah = [(Z/2) (I/R)
(Sa/g)]
Response reduction factor R = 4.0
Importance factor, I =1.5
Damping = 4%
Value of Sa/g is taken from Fig.2 (For Medium Soil)

4.4 Load Combinations Limit State of Collapse:

a. When Tank is Full b. When Tank is


Empty
101. 1.5DL + 1.5LL+1.5WHL 151. 1.5DL + 1.5LL
102. 1.5DL + 1.5WRL+1.5WDL 152. 1.5DL + 1.5WDL
103. 1.5DL + 1.5WRL+1.5SXF 153. 1.5DL + 1.5SXE
104. 0.9DL + 0.9WRL+1.5WDL 154. 0.9DL + 1.5WDL
105. 0.9DL + 0.9WRL+1.5SXF 155. 0.9DL + 1.5SXE
106. 1.2DL + 1.2LL + 1.2WRL+1.2WDL 156. 1.2DL + 1.2LL +1.2WDL

Page 6 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

107. 1.2DL + 1.2LL + 1.2WRL+1.2SXF 157. 1.2DL + 1.2LL + 1.2SXE


Limit State of Serviceability:
a. When Tank is Full b. When Tank is
Empty
201. 1.0DL + 1.0LL+1.0WHL 251. 1.0DL + 1.0LL
202. 1.0DL + 1.0WRL+1.0WDL 252. 1.0DL + 1.0WDL
203. 1.0DL + 1.0WRL+1.0SXF 253. 1.0DL + 1.0SXE
204. 0.9DL + 0.9WRL+1.0WDL 254. 0.9DL + 1.0WDL
205. 0.9DL + 0.9WRL+1.0SXF 255. 0.9DL + 1.0SXE
206. 1.0DL + 1.0LL + 1.0WRL + 1.0WD 256. 1.0DL + 1.0LL +1.0WDL
207. 1.0DL + 1.0LL + 1.0WRL + 1.0SXF 257. 1.0DL + 1.0LL + 1.0SXE
Note:
DL: Dead Load
LL: Live Load
WHL: Hydrotest Water Load
WRL: Working Water Load
WDL: Wind Load
SXF: Seismic load when tank is Full SXE: Seismic load when tank is
Empty

5 STRUCTURAL DESIGN

5.1 Reinforced concrete structure

Design is based on the worst possible combination of various loads, moments, and shear
resultant stresses in the tank in following cases.

Tank Full Tank Empty

Uplift pressure if any

Peripheral wall is designed for the following loads.

Hydrostatic test condition – Water depth up to full height of the wall(including free board)

Page 7 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

5.2 Foundation

Foundation for the structures is decided based on loading arrangement, load intensity and soil
strata. Design of foundation dependent upon the safe bearing capacity at that level and on the
basis of recommendation furnished in the Geotechnical Investigation report.

Design forces and moments are obtained from STAAD-Pro analysis and checked for bearing
capacity, overturning and sliding. Bearing Capacity is increased by 25% for all the loads
combination with wind/seismic. The foundation are designed as per limit state method as per
IS: 456:2000

5.3 Stability

Foundation is checked for Stability against wind load, Seismic load.

Page 8 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

6.0 LOAD CALCULATIONS

Page 9 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

(6) LOAD CALCULATION

(6.1) Dead Load Calculation

(a) Self weight of tank:

Dead weight of structure is applied using 'Self Weight' command

in STAAD

(b) Super Imposed Dead Load:


Roof finish/Water proof treatment = 1.8 kN/m2

(c) Water load on Wall and Bottom Slab:


Cover

Tank Wall

Base Slab
Ring Beam

Under Hydrotest condition :

Pressure at Bottom of Wall = 10 x 4.45 = 44.5 kN/m2

Under Working condition :

Pressure at Bottom of Wall = 10 x 4.15 = 41.5 kN/m2

Page 10 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

(6.2) Live Load Calculation

Live load on Cover Slab and Gallery = 1.5 kN/m2

Live load on Staircase = 5 kN/m2

Page 11 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

(6.3) Seismic Analysis of Tank And Load calculation

(i) DATA

Actual Capacity of Tank = 161.06 m3


Internal Diameter of tank at Top level 7.16 m

Thickness of tank wall at 1/3 from base = 6.243333 mm

Staging Height above ground level 12 m

Mass of empty container = 634.64 x 1000/9.81 = 64694 kg

Select Earthquake Zone IV

Select Soil type Medium soil

Grade of concrete M30

Unit weight of RCC= 25 kN/m3


Unit weight of PCC= 24 kN/m3
Unit weight of water= 9.81 kN/m3

Density of water = 1000 kg/m3


0.005 m

MW
0.3

7.16 m

4.15 m

LWL 0.25 m 0.15 m


0.00m

Page 12 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

1 m
Ring
Beam
Floor Beam Staging Columns
0.4 x 0.70

(ii) Calculation for CG of container and weight of container

Height of CG of empty container above bottom slab level (TOC)

Component of Weight CG Weight X CG


Tank container kN m KN-m

π x (7.16 + 0.006245)
Cylindrical Wall x 0.006245 x 4.445 15.6238 2.2225 34.72
x 25 =

(π x 7.17248²/4) x
base slab 252.527 -0.145 -36.62
0.25 x 25 =
π x (7.17248 + 1) x 1
Balcony Slab 96.2798 -0.075 -7.22
x 0.15 x 25 =
22.96 x 0.45 x 0.4 x
base beams 103.32 -0.495 -51.14
25 =

π x (7.16+0.5) x 0.5x
Ring Beam 135.363 -0.495 -67.00
0.45 x 25 =

Plaster/screed (π/4) x7.16² x 0.02 0.80528 -0.01 -0.01

Total = 634.645 -104.8

Page 13 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

Total Weight of Empty Container = 634.6 kN

Height of CG above Base slab level= -104.81/634.64 -0.17 m

Calculation for weight of staging:

Total weight of outer columns = 6 x ( 0.4 x 0.4 x 12.85 x 25) = 242.1 kN

Total weight of inner columns = 0 x (0 x 0 x 18 x 25) = 0.0 kN

LEVEL Label B D Length Weight

mm mm m kN

PB1 300 500 23.0 86.25


Plinth Beam:

TB1 300 500 23.0 86.25


Level 1:

TB2 300 500 23.0 86.25


Level 2:

TB3 300 500 23.0 86.25


Level 3:

TB4 300 500 0.0 0


Level 4:

TB9,TB10 300 500 0.0 0


Level 5:
Staircase Beam
SB 8 Nos. 350 350 1 74.9
and Steps

Staircase Flight1 FL 6 Nos. 1000 160 6.3 151.352091

Staircase Flight2 FL 1 Nos. 1000 160 4.2 16.8253485

TOTAL = 588.08

Total Weight of staging = 242.09 + 0 + 588.077439363634 = 830 kN

Total Mass of Staging supporting tank = 830.17 x 1000/9.81 = 84625 kg

(iii) Parameters of Spring Mass Model

Page 14 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

Height of circular tank, h = 4.15 m

Weight of water = 161.06 x 9810 = 1579999 N

Total mass of liquid in tank container, m = 1579998.6 x 9.81= 161060 kg

height/Diameter, h/D = 4.15 / 7.16= 0.58

Diameter/height, D/h = 1.73

Corresponding to h/D ratio from Fig. 2 IS 1893 (Part 2) :2014

For h/D =0.58 Kch/mg = 0.79

For h/D =0.58 mi/m = 0.61

For h/D =0.58 mc/m = 0.39

For h/D =0.58 hi/h = 0.38

For h/D =0.58 hc/h = 0.63

For h/D =0.58 hi*/h = 0.70

For h/D =0.58 hc*/h = 0.74

From the above parameters:

Spring stiffness of convective mode, Kc = 300902.1 N/m

Impulsive mass of liquid, mi = 97456.53 kg

Convective mass of liquid, mc = 62142.05 kg

Impulsive Height (Without considering base pressure), h i = 1.56 m

Convective Height (Without considering base pressure), hc = 2.62 m

Impulsive Height (Considering base pressure), hi* = 2.91 m

Convective Height (Considering base pressure) , h c* = 3.09 m

(iv) Stiffness of staging:

Stiffness of staging is calculated from STAAD Model

Diameter, D = 400

Load applied on Staging Top = 10.00 kN

Maximum Deflection at top of staging = 1.740 mm

Page 15 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

Effective Stiffness of staging, Ks = 10x1000/1.74 = 5.75E+03 N/mm

Ks = 5747.13 x 1000 = 5.75E+06 N/m

Mass of empty container + One-third mass of staging, m s = 92902 kg

Total Dead Load of Tank = 92902 x 9.81/1000 = 911.3686 kN

Tank is analysed with single degree of freedom with its mass concentrated
at CG of tank.

(v) Time Period

The time period Ti, of tank is calculated as per IS 1893:2014 (Part-2)

Time period of impulsive mode, Ti, in sec, is given by:

When Tank Full:

=2 x π x [(97456.53 + 92902)/(5747126.44)]^0.5 = 1.14 Sec

When Tank Empty:

Ti = 2π (ms/Ks)0.5 = 2 x π x [92902/5747126.44)]^0.5 = 0.80 Sec

Time period ofconvective mode, T1, in sec, is given by:

For h/D =0.58, Cc = 3.32

= 3.32 x [7.16/9.81]^0.5 = 2.84 Sec

(vi) Design Horizontal Seismic Coefficient

Design Horizontal Seismic coefficient is given by :

Page 16 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

IS:1893 where, Zone Factor, Z = 0.24

(Part 2) (Table:1, IS 1893 (Part-2) Importance Factor, I = 1.5

2014 (Table:2, IS 1893 (Part-2) Response reduction Factor (For OMRF) R = 4

Spectral Acceleration , (Sa/g)


Design horizontal seismic coefficient for impulsive mode,

Time period of impulsive mode when tank full, Ti = 1.14 sec

For Medium soil soil and 5% damping, corresponding (Sa/g)i = 1.19

The design horizontal seismic coefficient, ( Ah)i = 0.054

Base Shear Vi = (Ah)i (mi + ms) g = 99943 N

Design horizontal seismic coefficient for Convective mode,

Time period of impulsive mode, Tc = 2.84 Sec

For Medium soil soil and 5% damping, corresponding (Sa/g)c = 0.48

Multiplication factor for 0.5 % damping = 1.75

(Sa/g)c for 0.5 % Damping = 1.75 x 0.479 = 0.84

The design horizontal seismic coefficient, ( Ah)c = 0.0380

Base Shear Vc = (Ah)c mc g = 23165.3 N

Total base shear at the bottom of staging,


Total Base Shear, V = (Vi2 + Vc2)0.5 102592.5 N

V= 102.59 kN

This load is applied at 6 points in Seismic case (At Top of each Column)

Load applied in X-direction in seismic case under tank full


103/6 = 17.10 kN
condition =
(viii) Hydrodynamic Pressure

Impulsive Hydrodynamic Pressure

Impulsive Hydrodynamic Pressure on wall

Page 17 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

Maximum pressure will occur at Ø = 0.

At base of wall, y = 0 ;

Qiw( y = 0) = 0.7829

Impulsive pressure at the base of wall,

piw(y=0) = 1.71 kN/m2

No. y/h Y Qiw Piw

1 0 0.00 0.783 1.71


2 0.1 0.42 0.775 1.69
3 0.2 0.83 0.752 1.64
4 0.3 1.25 0.712 1.55
5 0.4 1.66 0.658 1.43
6 0.5 2.08 0.587 1.28
7 0.6 2.49 0.501 1.09
8 0.7 2.91 0.399 0.87
9 0.8 3.32 0.282 0.61
10 0.9 3.74 0.149 0.32
11 1 4.15 0.000 0.00

For stress analysis of tank wall, Impulsive and Convective pressure on wall
is converted to equivalent linear distribution.

Base shear due to impulsive liquid mass per unit circumferential length,

Page 18 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

(0.054 x 97456.53 x 9.81)/(π x 7.16/2) = 4.55 kN/m

Pressure at Bottom and Top is given by:

1.92 kN/m2

0.27 kN/m2

4.50
4.00 0.27

3.50
3.00
2.50
2.00
1.50 =
1.00
0.50
0.00
0.00 1.00 2.00 1.92
Impulsive Pressure on Wall

Impulsive hydrodynamic pressure on the base slab (y=0)

on a strip of length l' is given by:

Page 19 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

l' = D/2 = 3.58

x= D/2 = 3.58

pib = 3.09 kN/m2


Convective Hydrodynamic Pressure

Convective hydrodynamic pressure on wall,

Maximum pressure will occur at Ø = 0.

At base of wall, y = 0 ;

Qcw( y = 0) = 0.13

Convective pressure at the base of wall,

pcw ( y = 0 ) = 0.23 kN/m2


At y =h;
Qcw( y = h) = 0.563

Convective pressure at y = h,

pcw ( y = h ) = 1.0009 kN/m2


No. y y/D Qcw Pcw

1 0.00 0.000 0.132 0.2347


2 0.42 0.058 0.135 0.24
3 0.83 0.116 0.144 0.2563
4 1.25 0.174 0.160 0.2842
5 1.66 0.232 0.183 0.3251
6 2.08 0.290 0.214 0.3808
7 2.49 0.348 0.255 0.4538
8 2.91 0.406 0.308 0.5474
9 3.32 0.464 0.374 0.666

Page 20 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

10 3.74 0.522 0.458 0.8149


11 4.15 0.580 0.563 1.0009

Base shear due to impulsive liquid mass per unit circumferential length,

(0.038 x 62142.05 x 9.81)/(π x 7.16/2) = 2.06 kN/m

Pressure at Bottom and Top is given by:

0.11 kN/m2

1.59 kN/m2

1.59
6.00
5.00
4.00
3.00 =
2.00
1.00
0.00
1 1.5 2 2.5
0.11
Convective Pressure on Wall

Convective hydrodynamic pressure on the base slab (y = 0)

x = horizontal distance of a point on base of tank in the

Page 21 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

direction of seismic force, from the centre of tank.

x = D/2 = 3.58 m

Qcb (x ) = 0.088

Convective pressure on top of base slab ( y = 0 )

pcb = 0.235 kN/m2


Pressure Due to wall Inertia

Pressure on wall due to its inertia,

= 0.008 kN/m2
This pressure is uniformly distributed along the wall height.

Pressure Due to Vertical Excitation


Hydrodynamic pressure on tank wall due to vertical

ground acceleration,

y= vertical distance of point under consideration from bottom of

tank wall

IS:1893 where, Zone Factor, Z = 0.24

(Part 2) Importance Factor, I = 1.5

2014 Response reduction Factor (For OMRF) R = 4

Spectral Acceleration , (Sa/g)

Time period of vertical mode of vibration , T = 0.30 sec

Time period of vertical mode of vibration is recommended as 0.3 sec for 5% damping.

For Rock or Hard soil and 5% damping, corresponding (S a/g)i = 2.50

The design horizontal seismic coefficient, ( Ah)i = 0.08

Page 22 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN

At the base of wall, i.e., y = 0,

pv = 3.053363 kN/m2

Maximum Hydrodynamic Pressure on wall

= 3.642 kN/m2
Hydrostatic pressure under hydrotest condition = 10 x 4.45 = 44.500 kN/m2
Hydrostatic pressure under Working condition = 10 x 4.15 = 41.500 kN/m2

This maximum hydrodynamic pressure is about 8.78% of hydrostatic


pressure under working condition at base (ρgh = 41.5 kN/m2).
Container of tank is designed for hydrotest condition. When
earthquake forces are considered, permissible stresses are increased
by 33%. Hence, hydrodynamic pressure in this case does not affect
container design.

(ix) Analysis for tank Empty condition

Mass of empty container + (1/3) mass of staging, ms = 92902 kg

Time Period

Time period of impulsive mode,

= 0.799 Sec

Design Horizontal Seismic Coefficient


For T = 0.8 sec = Sa/g for 5% Damping = 1.702

Ah = 0.077

Base Shear

Total base shear,


V = Ah ms g = 70.18 kN

This load is applied at 6 points in Seismic case (At top of each Column)

Page 23 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


TITLE : 150KL 12m OHT
RKA DN
Load applied in X-direction in seismic case under tank Empty
70/6 = 11.70 kN
condition =

Page 24 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. Date


PROJECT:
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

(6.4) Wind Load Calculation

Basic wind Speed considered (Vb) = 47.00 m/sec

Design Wind Speed is given by Vz = K1 x K2 x K3 x Vb

Risk Coefficient, K1 (Table:1 IS 875 - PART 3) = 1.00

Table 2: Terrain, Height and structure size Coefficient (K 2 - 0m to 10m)= 1.00

IS 875 Terrain, Height and structure size Coefficient (K 2 - 10m to 15m)= 1.05

(PART 3) Terrain, Height and structure size Coefficient (K 2 - 15m to 20m)= 1.07

(for Terrain Catergory = 2)

Topography Factor (K3) = 1.00

Importance factor for cyclonic region (K4) 1.15

Design Wind Speed is given by Vz (0m- 10m) = 47 x 1 x 1 x 1x1.15 = 54.05 m/sec

Design Wind Speed is given by Vz (10m- 15m) = 47 x 1 x 1.05 x 1x1.15 = 56.75 m/sec

Design Wind Speed is given by Vz (15m- 20m) = 47 x 1 x 1.07 x 1x1.15 = 57.83 m/sec

Design Wind Pressure (0m - 10m) = pz 0.6 x 54.05² = 1.75 N/m2

Design Wind Pressure (10m - 15m) = pz 0.6 x 56.75² = 1.93 N/m2

Design Wind Pressure (15m - 20m) = pz 0.6 x 57.83² = 2.01 N/m2

CL 7.2 Wind directionality factor Kd 1.00

CL 7.2.1 Area averaging factor ka 0.80

Combination Factor kc 1.00

Design wind Pressure Pd = KdxKaxKcxPz

Design Wind Pressure (0m - 10m) = pd = KdxKaxKcxPz 1.753x 1x 0.8x 1 = 1.40 N/m2

Design Wind Pressure (10m - 15m) = pd = KdxKaxKcxPz 1.932x 1x 0.8x 1 = 1.55 N/m2

Design Wind Pressure (15m - 20m) = pd = KdxKaxKcxPz 2.007x 1x 0.8x 1 = 1.61 N/m2

For all Circular members in Plan consider Shape Factor as 0.7

Page 25 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. Date


PROJECT:
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

Projected area of the Tank upto top of bottom slab

Shape factor for circular Structure= 0.70

a) Wind load on Cylindrical Wall

Projected area of cylindrical wall = 7.17248 x 4.45 = 31.92 m2

Wind load acting on the projected area (0m - 10m) = 0.7 x 1.4= 0.98 kN/m2

Wind load acting on the projected area (10m - 15m) = 0.7 x 1.55= 1.09 kN/m2

Wind load acting on the projected area (15m - 20m) = 0.7 x 1.61= 1.13 kN/m2

Wind load acting on the projected area (20m - 30m) = 0.7 x 1.76= 1.23 kN/m2

For Load application in staad

Equivalent Wind load normal to surface (0m - 10m) = 0.98 / π/2 0.62 kN/m2

Equivalent Wind load normal to surface (10m - 15m) = 1.09 / π/2 0.69 kN/m2

Equivalent Wind load normal to surface (15m - 20m) = 1.13 / π/2 0.72 kN/m2

Equivalent Wind load normal to surface (20m - 30m) = 1.23 / π/2 0.78 kN/m2

b) Wind load on staging

Staging Height = 12.00 m

Columns along wind (Outer columns) = 4 Nos

Outer Column diameter = 0.400 m

Inner Column Diameter = 0.000 m

Frame area of staging = 12 x 7.17248 = 86.07 m2

No. of tie level beam exposed to wind = 4 Nos

Area of beams exposed to wind = 4 x (7.16-4 x 0.4) x 0.5 = 11.12 m2

Area of columns exposed to wind = 4 x 12 x 0.4 = 19.20 m2

Total exposed Area of staging = 11.12 + 19.2 = 30.32 m2

Solidity Ratio 30.32/86.06976 = 0.35

From table - Force Coefficient for flat-sided Members, Cf = 1.65


31 of IS 875 Force Coefficient for Circular-Sections, Cf = 0.80

Page 26 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. Date


PROJECT:
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

For 0 m -10 m

Force on outer columns 1.65 x 0.4 x 1.4 = 0.92 kN/m

Force on inner columns 1.65 x 0 x 1.4 = 0.00 kN/m

Force from Tie Beam 1.65 x 1.4 x 2.87 x 0.5 = 3.31 kN

Force from base level Beam 1.65 x 1.4 x 2.87 x 0.45 = 2.98 kN

For 10 m -15 m

Force on outer columns 1.65 x 0.4 x 1.55 = 1.02 kN/m

Force on inner columns 1.65 x 0 x 1.55 = 0.00 kN/m

Base level beams & Tie Beams

Force from base level Beam 1.65 x 1.55 x 2.87 x 0.45 = 3.30 kN

Force from Tie Beam 1.65 x 1.55 x 2.87 x 0.5 = 3.67 kN

For 15 m -20 m

Force on outer columns 1.65 x 0.4 x 1.61 = 1.06 kN/m

Force on inner columns 1.65 x 0 x 1.61 = 0.00 kN/m

Base level beams & Tie Beams

Force from base level Beam 1.65 x 1.61 x 2.87 x 0.45 = 3.43 kN

Force from Tie Beam 1.65 x 1.61 x 2.87 x 0.5 = 3.81 kN

Page 27 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

7.0 DESIGN OF TANK


8.0 DESIGN OF STAGING

Page 28 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

(7) DESIGN OF TANK CANTAINER

(7.1) BASIC DESIGN DATA:

Capacity of Tank 150 m3


Diameter of Tank = 7.16 m

Inside radius of the cylindrical wall of the tank =7.16/2 = 3.58 m

Unit weight of RCC= 25 kN/m3


Unit weight of PCC= 24 kN/m3
Unit weight of soil = 18 kN/m3
Unit weight of water= 9.81 kN/m3
SBC as per soil report = 80 kN/m2
Depth of foundation as per soil report recommendations = 2 m

Staging Height above FGL = 12 m

Depth of foundation belowFGL = 2 m

Number of staging columns (Outer) = 6 Nos.

Number of staging columns (Inner)= 0 Nos.

Height of staging = 12.0 m

Thickness of tank wall at top = 6.25 mm

Thickness of tank wall at bottom = 6.24 mm

Liquid depth = 4 m

Free board from soffit of lowest beam = 0.3 m

Liquid depth including free board = 4 + 0.3 + 0.15 = 4.45 m

Depth of cover slab beam = 0 m

Dead Storage = 0.15 m

(7.2) PERMISSIBLE STRESS:

Grade of concrete fck = 30 N/mm2


Grade of steel fy = 500 N/mm2
Allowable stress as per IS:3370 relating to resistance to cracking
Ref Table
1 of
Allowable direct tensile stress in concrete σat = 1.5
IS:3370
Allowable bending tensile stress in concrete σbt = 2.0

Ref Tab. 4 Allowable stress in steel under direct tension, bending & shear = σ st = 275
of IS:3370
Allowable stress in steel under direct compression = σ sc= 190

Page 29 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN
IS
Allowable stress in steel under direct tension, bending & shear = σ st = 275
456:200
IS
Allowable stress in steel under direct tension, bending & shear = σ st = 275
456:200
Allowable direct compressive stress in concrete σcc = 8

Allowable bending compressive stress in concrete σcbc = 10

Design constants:

Modular ratio = m= 280/(3x σcbc) 9.33

For M30 concrete and Fe500 steel

Neutral axis co-efficient; n= m x σcbc/(m x σcbc+σst) For σst =275 0.25

Lever arm coefficient; j = 1-n/3 = For σst =275 0.92

For σst =275 0.92

Limiting Moment, M = Qbd2


Where Q = σ /6 = 0.33

Allowable stress in steel under direct tension, bending & shear = σst = 275 N/mm2
Permissible shear stress tcmax= 3.5 N/mm2
(7.3) Volume calculation

Volume of cylindrical tank (V1) = = π (3.58)²(4.45 - 0.3- 0.15) = 161.06 m3

m3
Extra volume due to inside tapered wall (V2) =(0.00624-0.00625)x4/2 x π x(7.16+(0.00624-0.00625)/3)=
0.00

Thickness of Plaster = 20.00 mm

Volume of columns including Plaster(V3) = 0 x (0.34 x 0.34) x (4.45-0.3-0.15) 0.00 m3


Volume of Plastering on walls (V4)= π (7.16-0.02)x4x0.02 = 0.00 m3
Total volume of tank (live storage)= V1 + V2 -V3- V4 = 161.06 + 0-0-0 = 161.06 m3
Volume including free board = 161.06 + π (3.58)²(0.3+0.15) = 179.18 m3

161.06 > 150 (OK)

Page 30 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

(7.4) Design of Base Slab of Tank

a. Interior Panel:

Length of panel (Lx)= 3.580 m

Width of panel (Ly) = 3.580 m

Ly/Lx = 1.00

Two way slab

Thickness of the Slab = 250 mm

Self weight of Slab (wg) = 0.25 X 25 = 6.25 kN/m2


Load due to water = 44.50 kN/m2

Load of finishings/water proofing, wf = 1.8 kN/m2


Total load, w = 6.25 + 44.5 + 0 + 1.8 = 52.55 kN/m2
Effective span of slab = 3.58 - 0.4 = 3.18 m
Table 26
Maximum +ve moment at mid span = 0.024 x 52.55 x 3.18² = 12.75 kNm
IS 456-
2000 Maximum -ve moment moment at top of support = 0.032 x 52.55 x 3.18² = 17.01 kNm

Depth required = (M/Q b)0.5= [19.66 x 10^6/(0.33 x 1000)]^0.5 = 244.1 mm

OK Safe

Area of steel required on Bottom face (Mid Span):

Maximum BM causing tension on bottom face, M = 12.75 kN-m/m

Diameter of bar provided = 12 mm

Cover to the reinforcement = 30 mm

Effective depth ofslab = 250-30-12/2 = 214 mm

Area of steel required for bending = = M/σst X j X d = 235.56 mm2/m

Minimuml reinforcement required 0.35 %

Minimum Area of steel required on each face= 437.50 mm2/m

Provide 12 mm dia tor steel at a spacing = 105 mm c/c

Provide 12 mm Dia. bar @ 105 mm c/c on bottom face in both direction

Area of steel provided = 1077.1 mm2/m

percentage of steel provided = 0.5 %

Area of steel required on top face (Support):

Maximum BM causing tension on top face, M = 17.01 kN-m/m

Diameter of bar provided = 10 mm

Cover to the reinforcement = 30 mm

Page 31 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

Effective depth of slab = 250-30-10/2 = 215 mm

Area of steel required for bending = =M/σst X j X d = 312.62 mm2/m

Minimuml reinforcement required 0.35 %

Minimum Area of steel required on each face= 437.50 mm2/m

Provide 10 mm dia tor steel at a spacing = 150 mm c/c

Provide 10 mm Dia. bar @ 150 mm c/c on top face in both direction

Area of steel provided = 523.6 mm2/m

percentage of steel provided = 0.24 %

Check for Deflection:

Ast required = 235.56 mm2/m


Ast provided = 1077.1 mm2/m
pt provided = 0.503 %

fs = 0.58 x fy x ( Ast req/Ast pro) = 63 N/mm2


Effective span = 3.18 m
fig 4,
Modification Factor = 2
IS:456-
2000 span / effective depth = 3.18 / 0.214 = 14.86

< 26 x 2 = 52 safe

b. End panel: One end Discontinous : As per table 26 of IS 456-2000

Length of panel (Lx)= 4.032 m

Width of panel (Ly) = 4.032 m

Ly/Lx = 1.000

Two way slab

Table 26
Maximum +ve moment at mid span = 0.028 x 52.55 x 3.18² = 14.88 kNm
IS 456-
2000 Maximum -ve moment at top of support = 0.037 x 52.55 x 3.18² = 19.66 kNm

Area of steel required for +ve moment:

Maximum BM causing tension on bottom face, M = 14.88 kN-m/m

Area of steel required for +ve moment = =M/σst X j X d = 274.82 mm2/m

274.82 mm² < 1077.12 mm²(OK)

Area of steel required for -ve moment:

Maximum BM causing tension on bottom face, M = 19.66 kN-m/m

Page 32 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

Area of steel required for -ve moment = =M/σst X j X d = 361.47 mm2/m

361.47 mm² < 523.6 mm²(OK)

(7.5) Design of Base slab level beams

Taking maximum moment from staad and doing the typical beam design

Effective span of beam = 7.160 m


Clear Span of beam = 7.16-0.4 = 6.76 m

Width of beam, b = 400 mm

Depth of beam, D = 700 mm

Maximum -ve Bending moment/Support Moment ( From Staad ) = 100.00 kN-m

Maximum +ve Bending moment/ Span Moment ( From Staad ) = 118.00 kN-m

Maximum shear force, V ( From Staad ) = 114 kN

Beam is checked as T-beam for combined action


Thickness of the flange (Df) = 250 mm

lo = 7.16 mm
Distance between points of zero moments (l o) = 0.7 x 7.16 = 5.01 mm
Breadth of web (bw) = 400 mm
Depth of web = 700-250 = 450 mm
Breadth of flange (bf) = lo/6 + bw + 6Df = 2735 mm

2735

250
yt

N A
450 yb

400

Depth of NA from top face (yt) = 198 mm


Depth of NA from bottom face (yb) = 502 mm

Total cross sectional area of the T-beam (A) = 863750 mm2

Moment of inertia about NA (INA) = 2.4054E+10 mm4

Section modulus about bottom face, Z t = INA/yt= 121482938 mm3

Bending tensile stress (sbt) = (100 x 10^6)/121482937.71 = 0.82 N/mm2

Page 33 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

< 2 OK

Design for negative steel (Support Section):


Maximum BM causing tension on support section, M = 100.00 kN-m

Cover to main reinforcement = 45 mm

Diameter of bar : 1 = 16 mm

Diameter of bar : 2 = 16 mm
Effective depth provided ,d = 700 - 45 - 16/2 = 647 mm
Area of steel required for -ve moment = =M/σst X j X d = 610.91 mm2/m

Minimum percentage of steel = 0.17 %

Minimum reinforcement required = (0.17/100) x 400 x 647 = 439.96 mm2

Area of steel provided = 1407.43351 mm2

Provide 4 Bars of 16 mm Diameter, 3 Bars of 16 mm Diameter

Design for Positive steel (Span section):


Maximum BM causing tension on span section, Mu = 118.00 kN-m

Cover to main reinforcement = 30 mm

Diameter of bar : 1 = 16 mm

Diameter of bar : 2 = 16 mm
Effective depth provided ,d = 700 - 30 - 16/2 = 662 mm
Area of steel required for +ve moment = =M/σst X j X d = 704.54 mm2/m

Minimum percentage of steel = 0.17 %

Minimum reinforcement required = (0.17/100) x 400 x 662 = 450.16 mm2

Area of steel provided = 1407.43 mm2

Provide 4 Bars of 16 mm Diameter and 3 Bars of 16 mm Diameter

Check for shear:

Maximum Shear Force,V = 114

The nominal shear stress on the section is, tv= V/bd = 0.43 N/mm2

Maximum shear stress tcmax = 3.5 N/mm2


OK SAFE

The tension reinforcement available at this section is

Ast= 1407.43 mm2

100Ast/bd = 1407.43 x 100/(400 x 662) = 0.53 %

The allowable shear stress for 0.53 % tension reinforcement is

Page 34 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

tc = 0.32 MPa

Since the nominal shear stress is more than shear capacity of the concrete,
stirrups are to be provided.

Diameter of stirrups = 10 mm

Design Spacing of stirrups = =(σstAsvd)/(tv-tc)bd = 943

Nominal spacing of 2-legged 10 mm dia stirrup required:


= (0.87 x fy x Asv)/0.4b = 350 mm
= 0.75 x d 496.5 mm

Provide stirrup at a spacing of = 150 mm


Provide 10 mm dia. 2- legged stirrups at 150 mm c/c.

Check for Deflection:

L/D = 7.16 x 1000/662 = 10.82

10.82 < 26 (OK)

(7.6) Design of Balcony

Width of balcony = 1000 mm

Clear cantilever span = 1000 mm

Effective span of cantilever = 1000 mm

Depth of balcony slab = 150 mm

Live load 5.00 kN/m2

Self weight = 3.75 kN/m2

Finishing Load = 1.00 kN/m2

Total load, w = 3.75 + 5 + 1 = 9.75 kN/m2

Maximum bending moment, M = wL2/2 = 9.75 x 1²/2 = 4.88 kN-m

Shear Force, V = wL = 9.75 kN

Moment, M = 4.88 kN-m

Shear Force, V = 9.75 kN


Design for Bending:
Depth required = d= (Mu/Qb)0.5 = 4.88 x 10^6/(0.33 x 1000) = 38.44 mm
38.44 < 116 (OK)

Maximum BM causing tension on span section, M = 4.88 kN-m/m

Cover to main reinforcement = 30 mm

Diameter of bar = 8 mm

Page 35 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

Effective depth provided ,d = 150 - 30 - 8/2 = 116 mm


2
R= Mu/bd = 0.36 Mpa

Pt =(30/2/500) X (1-SQRT(1-4.598 X 0.36/30)) X 100 = 0.08 %

Area of steel required for moment = 97.37 mm2

Minimum percentage of steel = 0.12 %

Minimum reinforcement required = (0.12/100) x 1000 x 150 = 180.00 mm2

Spacing of bar required = 150 mm

Provide 8 mm diameter bar @ 150 mm c/c on top face of walkway platform

Area of steel provided = 335 mm2

Distribution steel:

Diameter of distribution steel = 8 mm

Spacing of distribution bars = 150 mm

Provide 8 mm diameter bar @ 150 mm c/c in circumferential direction on top


face of walkway platform

Check for shear:


Shear Force, V = 9.75 kN
The nominal shear stress on the section is, tv= V/bd = 0.08 N/mm2
Maximum shear stress tcmax = 3.5 N/mm2
OK SAFE

The tension reinforcement available at this section is

Ast= 335.10 mm2


100Ast/bd = 335.1 x 100/(1000 x 116) = 0.29 %

The allowable shear stress for 0.29 % tension reinforcement is


tc = 0.24 MPa
Since the nominal shear stress is less than shear capacity of the concrete,
No shear Reinforcement required.
Check for Deflection:
Ast required = 97.37 mm2/m
Ast provided = 335.1 mm2/m
pt provided = 0.289 %
fs = 0.58 x fy x ( Ast req/Ast pro) = 84 N/mm2
fig 4,
Effective span = 1 m
IS:456-

Page 36 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN
IS:456-
2000 Modification Factor = 2
span / effective depth = 1 / 0.116 = 8.62
< 7 x 2 = 14 safe

(7.11) DESIGN OF RING BEAM

Thickness of Base Slab = 250 mm

Span of Beam = 4.01 m

Size of the beam : Breadth (b) = 500 mm

Depth (D) = 700 mm


Maximum span moment (Mspan) = 100.00 kN-m
Maximum support moment (Msupp)= 138.00 kN-m
Max shear force (V) = 175.00 kN
Torsional moment (Mt)= 9.14 kN-m
Equivalent BM is given by, Me = M + Mt

Where, Mt = T (1 + D/b)

1.7

= = 9.14 (1 + 700/500) 12.9 kN-m

1.7
Equivalent SF is given by, Ve = V + Vt

Where, Vt = 1.6 T/b

= 1.6 x 9.14/0.5 = = 29.25 kN

Equivalent BM creating tension on top face of the beam is


Met = 138 + 12.9 = 150.9 kN-m

Equivalent BM creating tension on bottom face of the beam is


Meb = 100 + 12.9 = 112.90 kN-m

Equivalent SF is
Ve = 175 + 29.25 = 204.25 kN
Beam is checked as L-beam for combined action
Thickness of the flange (Df) = 250 mm

lo = 4.01 m
Distance between points of zero moments (l o) = 4.01076662108297 = 4.01 m
Breadth of web (bw) = 500 mm

Depth of web = 700-250 = 450 mm

Page 37 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

Breadth of flange (bf) = lo/12 + bw + 3Df = 1584 mm

1584
250 yt

N A
450 yb

500
Depth of NA from top face (yt) = 252 mm
Depth of NA from bottom face (yb) = 448 mm

Total cross sectional area of the T-beam (A) = 621000 mm2

Moment of inertia about NA (INA) = 2.3435E+10 mm4

Section modulus about top face (Z t) = INA/yt= 92997952.4 mm3

Bending tensile stress (sbt) = 112900000/92997952.38= 1.62 N/mm2


< 2, OK

Design for negative steel (Support Section):


Maximum BM causing tension on support section, M et = 150.90 kN-m

Cover to main reinforcement = 45 mm

Diameter of bar : 1 = 16 mm

Diameter of bar : 2 = 16 mm
Effective depth provided ,d = 700 - 45 - 16/2 = 647 mm
Area of steel required for -ve moment = =M/σst X j X d = 921.86 mm2/m

Minimum percentage of steel = 0.17 %

Minimum reinforcement required = (0.17/100) x 500 x 647 = 549.95 mm2

Area of steel provided = 1407.43 mm2

Provide 4 Bars of 16 mm Diameter and 3 Bars of 16 mm Diameter

Design for Positive steel (Span section):


Maximum BM causing tension on span section, Meb = 112.90 kN-m

Cover to main reinforcement = 30 mm

Page 38 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

Diameter of bar : 1 = 16 mm

Diameter of bar : 2 = 12 mm
Effective depth provided ,d = 700 - 30 - 16/2 = 662 mm
Area of steel required for +ve moment = =M/σst X j X d = 674.09 mm2/m

Minimum percentage of steel = 0.17 %

Minimum reinforcement required = (0.17/100) x 500 x 662 = 562.70 mm2

Area of steel provided = 804.247719 mm2

Provide 4 Bars of 16 mm Diameter and 0 Bars of 12 mm Diameter

Check for shear:


Maximum Shear Force,Ve = 204.25 kN

The nominal shear stress on the section is, tv= V/bd = 0.62 N/mm2

Maximum shear stress tcmax = 3.5 N/mm2


OK SAFE

The tension reinforcement available at this section is

Ast= 804.25 mm2

100Ast/bd = 804.25 x 100/(500 x 662) = 0.24 %

The allowable shear stress for 0.24 % tension reinforcement is


tc = 0.22 MPa

Since the nominal shear stress is more than shear capacity of the concrete,
stirrups are to be provided.

Diameter of stirrups = 10 mm

Using 10 mm Diameter 2 - Legged stirrup


Asv = 157.08 mm2
b1 = 500- 30x2 - 16 = 424 mm
d1 = 700- 45x2 - 16 = 594 mm
Spacing of stirrup required, Sv = 280.3 mm

The Spacing is also controlled by


Sv=(σst x Asv)/((tv - tc) b) = (157.08 x 275)/((0.62-0.22) x 500) = 220 mm

However, the spacing should not exceed the least of x1, (x1+y1)/4, 0.75d and 300
mm, where
x1 = short dimension of stirrup = 424 + 16 + 10 = 450 mm

Page 39 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

y1 = long dimension of stirrup = 594 + 16 + 10 = 620 mm


(x1 + y1)/4 = 268 mm
Spacing of stirrup provided = 210 mm

Provide 2-legged 10 mm striupp at 210 mm Spacing

(8) DESIGN OF TANK STAGING

(8.1) Design of Columns

Total height of staging above ground level = 12 m

Depth of foundation below NGL = 2.00 m

Thickness of Footing = 0.45 m

Height of inner columns from top of footing = 12 + 2 - 0.7 - 0.45 = 12.85 m

Height of outer columns from top of footing = 12 + 2 - 0.7 - 0.45 = 12.85 m


(A) Outer columns :

Size of column, D = 400 mm

Cover to reinforcement = 45 mm

Area of steel required from staad 1242 mm2

Minimum Steel Requires as pe IS : 456-2000 = 1005 mm2

Diameter of Bar 1 = 16 mm

Diameter of Bar 2 = mm
Provide 8 Bars of 16 mm Diameter

Area of steel provided = 1608 mm2

Diameter of Ties = 8 mm

Spacing of ties required = 150 mm


Provide 8 mm Diameter Ties @ 150 mm c/c

Defclection check-

Deflection from staad= 21.000 mm

Allowable deflection = L/500 = 28 mm


OK

(8.2) Design of Tie beam/ Plinth beam

Number of level of bracings = 2 levels

Inner Width 300 mm

Depth 500 mm

Page 40 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DOCUMENT NO. DATE


PROJECT: JJM, UP
150/12/12/22

DESIGNED CHECKED PAGE


STRUCTURE: 150KL 12m OHT
RKA DN

BEAM DESIGN SUMMARY

Label Top reinforcement Bottom reinforcemts Stirrups


No. of
Size B Ast Ast No. of Bars Ast
Beam Ast Req. Bars
x D Prov. Req. provided Prov.
provided
PLINTH
PB1 300x500 642 4-Y16 804.2 527 4-Y16 804.25 Y8 @ 150 c/c
LEVEL

LEVEL 1 TB1 300x500 642 4-Y16 804.2 527 4-Y16 804.25 Y8 @ 150 c/c

LEVEL 2 TB3 300x500 642 4-Y16 804.2 527 4-Y16 804.25 Y8 @ 150 c/c

Page 41 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

9.0 DESIGN OF FOOTING

Page 42 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Design of Annular Raft


Grade of concrete ( f ck ) M30
Grade of steel ( f y ) Fe500
Total Load coming from columns 2940 kN
Maximum Bending moment due to wind 288 kNm
Extra surcharge due to part of soil replaced by the self
weight of concrete 147 kN
Total Weight 3087 kN
Say 3187 kN
Net Safe Bearing Capacity of Soil 80 kN/m
2
Soil bearing capacity in wind load case 100 kn/m
2
Area of Footing required (A) 39.84 m
Area of footing on either sides of ring beam is equal
Centre to centre diameter of staging 7.16 m
Radius of inner edge of Footing Ri

2.544 m
Say Ri 2.4 m
Radius of outer edge of Footing Ro

4.38 m
Say Ro 4.60 m

3.62 m

R 3.58 m
2
Area of Raft required 39.84 m
2 2 2
Area of Raft provided (A) = Π*(Ro - Ri ) 48.36 m
OK
4 4 3
Sectional modules of footing Z = Π*(Ro - Ri )/4Ro 70.78 m

Check for foundation :


2
Upward pressure for DL + LL case 65.91 kN/m
2
Net Upward pressure for DL + LL case 60.80 kN/m
2
Bearing capacity of soil 80 kN/m
Safe

Upward pressure for DL + WL case

Page 43 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

2
P/A + M/Z 69.98 kN/m
2
P/A - M/Z 61.84 kN/m
2
Soil bearing capacity in wind load case 100 kN/m
Safe
Safe
a) Design of Raft Ring Beam
Let the width of ring beam 500 mm
Depth of ring beam 700 mm
Size of column supporting beam 400 mm
The beam is supporting on no. of column 6
2α 60 1.047 rad
βo 12.75 0.223 rad
α 30 0.524 rad

Bending moment coefficients are


At support λ - 0.089
At span λ + 0.045
Torsional moment coefficient is λ t 0.009
2
Net upward pressure 69.98 kN/m
Load per meter run w 167.93 kN/m
Radius r 3.58 m
2
Max support moment = 2 α*w*r *λ + 200.60 kNm
2
Max span moment = 2α*w*r *λ - 101.42 kNm
2
Max torsional moment = 2α*w*r *λ t 20.28 kNm
Shear force at support (V o ) =Π*D*w/2*n 314.79 kN
Shear force at the section of maximum Torsion
V' = V 0 *(1-β o /α) 181.00 kN
Moment at face of column
2
wr *(-1+ α sinϴ + α cosϴ * cotα)
tan ϴ 0.06
ϴ 3.20 deg
0.06 rad
α sinϴ 0.029
α cosϴ * cotα 0.91

Moment at face of column M1 -140.6 kNm


Torsional moment at face of column
2
wr *(ϴ-α+α cosϴ - α sinϴ * cotα)
α cosϴ 0.5228
α sinϴ * cotα 0.0506

Torsional moment at face of column 9.48 kNm

Distance of max torsion from face of the supports

Page 44 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

(π*D*βo/360)-r 0.60 m
< 0.61
Equivalent Bending Moment at face of column M2 = T ( 1+D/b) / 1.7
D= 700 mm
b= 500 mm
M2 13.39 kNm
Total Bending Moment at face of column M =M1+M2
M 153.95 kNm
Effective depth of beam required dreq 277.8 mm
Dia of reinf. 20 mm
Dia of Stirrups 10 mm
Clear Cover 45 mm
Effective Depth 610 mm
Equivalent Bending Moment (where torque is maximum) M2 = T ( 1+D/b) / 1.7
28.6 kNm
Area of Reinforcement for support moment at face of column
2
Mu/bd 1.24
Percentage of steel required 1512.74541
2
Ast,req 1512.74541 mm
Area of Reinforcement for span moment
2
Mu/bd 0.82
Percentage of steel required as per SP-16 996.6249862
2
Ast,req 996.6249862 mm

LONGITUDINAL REINFORCEMENT:
At Bottom:
Straight Bars Extra Bars
Dia of Bar 20 mm 16
2
Area of Bar 314.2 mm 201.1
Required no. of Bars at bottom 4.82 no's
Provided no of Bars 4 no's 3
2
Provided Area of Steel at bottom 1256.6 mm 603.2
2
Total Provided Area of steel at bottom 1859.8 mm OK
At Top:
Straight Bars Extra Bars
Dia of Bar 20 mm 12
2
Area of Bar 314.2 mm 113.1
Required no. of Bars at top 3.17 no's
Provided no of Bars 4 no's 0
2
Provided Area of Steel at bottom 1256.6 mm 0.0
2
Total Provided Area of steel at bottom 1256.6 mm OK

At Bottom:
Provide 4- #20 tor through 3- #16 Extra

Page 45 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

At Top:
Provide 4- #20 tor through 0- #12 Extra

Shear force at d from face of column


V = Vo - w (d+S/2) 264.7 kN
Equivalent shear at section of maximum torsion
Ve = V'+1.6*T/b 245.9 kN
Equivalent Shear Stress
2
τve =1.5Ve/(bd) 1.21 N/mm
2
Area of Steel at Support 1859.8 mm
pt 0.61
From table 19 of IS 456, permissible shear stress of concrete τc
2
0.52 N/mm
Shear Capacity of section 158600 N
Net Shear 106100 N
TRANSVERSE REINFORCEMENT:
Dia of Stirrups 10 mm
No of Legs 2
Area of shear reinforcement as per Clause 41.4.3 of IS 456 -2000
Spacing should be lesser of the following
1). Asv/Sv = T/(b 1*d1*(0.87fy)+ Vu/(2.5d1 (0.87fy)
Dia of main reinforcement 20 mm
Dia of Stirrups 10 mm
Cover 45 mm
T 20284972.76 Nmm
V 181003.40 N
b1 370 mm
d1 570 mm
2
0.87f y 435 N/mm
2
Asv 157 mm
Asv/Sv 0.51
Sv 306.0 mm
2). Sv = (Asv*0.87f y) /(b*( τve-τc) 198.1 mm
Spacing is lesser of above two cases 198.1 mm
Say 100 mm

Ductile Detailing of Beam:


As per IS 13920 :2016
The first hoop shall be at a distance not exceeding 50 mm from the joint face. Vertical
Width of beam 500 mm
Depth of beam 700 mm
Clear cover 45 mm
Dia of Hoop 10 mm
Dia of main bar provided 20 mm
Effective depth 610 mm

Page 46 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

The spacing of hoops over a length of 2d at either ends of a beam shall not exceed
a) d/4 152.5 mm
b) 8 times the diameter of the smallest longitudinal bar 160 mm
c) 100 mm 100 mm
Min (152.5,160,100) 100 mm
Provide spacing at support 100 mm
Length of Confining steel from face of the support, 2d 1220 mm
Say 1250 mm
Stirrups:
Hence Provide 2L - Y8 stirrups @ 1000 mm c/c throught

b.) Design of Slab :


2
Net upward pressure 69.98 kN/m
Length of projection of footing inner side
Li = 3.58 - 2.4 - 0.2 1.0 m
Length of projection of footing outer side
Lo = 4.6 - 3.58 - 0.2 0.8 m
Bending Moment at inner face of ring beam Mi = 33.6 kNm
Bending Moment at outer face of ring beam Mo = 23.5 kNm
Effective depth of slab required 91.8 mm
Provided depth of footing at end 250 mm
Provided depth of footing at beam edge 450 mm
Dia of Main Reinforcement 12 mm
2
Area of Bar 113 mm
Clear cover 50 mm
Effective depth of slab 394 mm
Area of Reinforcement at face of Beam
from table 20 of SP:16
Steel Reinforcement
2
Ast 197.8 mm
Required Spacing (S) 571.45 mm
Provided spacing 200 mm
2
Area of Steel Provided 565 mm
2
Ast,min 472.8 mm
Provide 12 tor @ 200 mm c/c as radials ( spacing measured at outer face of ring beam )
Distribution Steel :
Minimum reinforcement 0.12 %
2
Area of cross section of footing inner side 0.58 m
Area of reinforcement 0.00070
2
0.0003 m in 1 m width
2
291.67 mm
Dia of Bar 10 mm
2
Area of bar 78.5 mm
Spacing required 269.1428571 mm
Spacing provided 200 mm

Page 47 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Provide 10 tor @ 200 mm c/c as Rings ( spacing measured at outer face of ring beam )

CHECK FOR PUNCHING SHEAR :


Shear force at a distance d/2 mm from face of ring beam 154.2 kN
Depth of footing at distance d/2 433.58 mm
Effective depth ' d ' 377.58 mm
2
Shear Stress τve = 1.5* Ve/(bd) 0.61 N/mm
2
τc =0.16√fck 0.88 N/mm
Hence, Safe

CHECK FOR BEAM SHEAR :


Shear force at a distance d from face of ring beam 41.01 kN
Total Depth of footing at distance d 417.17 mm
Effective depth ' d ' 361 mm
2
Shear Stress τve = 1.5* Ve/(bd) 0.17 N/mm
% of steel provided (p) 0.25
As per table -19 of IS 456-2000, Permissible shear stress 0.37
Hence Safe
All stresses for portion of footing on either side of ring
beam will be within permissible stresses as length of
projection is higher on inner side than outer side.

Page 48 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

10.0 DESIGN OF STAIRCASE

Page 49 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DATE
PROJECT: JJM, UP
150/12/12/22
DESIGNED CHECKED PAGE
TITLE 150KL 12m OHT
RKA DN
10.0 DESIGN OF STAIRCASE
10.1 Design of Staircase Flight:
Riser of staircase, R = 200 mm
Tread of staircase, T = 286.7 mm
Width of staircase = 1000 mm
Width of landing (clear) = 1000 mm
Assume thickness of waist slab = 160 mm
Clear cover to reinforcement = 30 mm
Grade of Concrete, fck = 30 N/mm2
Grade of steel, fy = 500 N/mm2
Loads
Live load acting on the staircase = 3 kN/m2
Load due to finishes = 1.2 kN/m2
2 2
Inclined length of each step = b = R +T 349.57 mm

1.00 1.00

0.35 2.88 0.35


3.58
PLAN

2.000

BEAM-

286.7 TANK
BEAM- STAGING
COLUMN
200

TANK 160
STAGING
COLUMN
SECTION A-A

Page 50 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DATE
PROJECT: JJM, UP
150/12/12/22
DESIGNED CHECKED PAGE
TITLE 150KL 12m OHT
RKA DN
1) Self weight of RCC step = 0.5 x 200/1000 x 25 = 2.5 kN/m2
Total dead load acting = 4 + 2.5 = 6.5 kN/m2
Total load on waist slab = 6.5 + 3 + 1.2 = 10.7 kN/m2
Load acting on landing slab:
1) self weight of slab = 0.16 x 25 = 4 kN/m2
Total dead load acting on the landing = 4 kN/m2
Live load = 3 kN/m2
Floor finish = 1.2 kN/m2
Total load on landing 3 + 4 + 1.2 = 8.2 kN/m2
Maximum bending moment and shear force:

8.2
0.35 kN/m 10.7 kN/m
2.88 0.358.2 kN/m
mmmmmmmmm MMMMMMMMMMMMMMMMMM mmmmmmmmmm

5.895 5.895
BENDING MOMENT DIAGRAM
16.989

18.278

18.278
SHEAR FORCE DIAGRAM

Design of waist slab/landing slab:


Maximum (+ve) BM = 16.989 kN-m/m
Maximum Shear force = 18.28 kN
Area of steel required on bottom face of waist slab at span
Mu =1.5 x 16.989= 25.48 kN-m/m
Diameter of bar provided = 12 mm
Effective depth of slab = 160 - 30 - 6 124 mm

Page 51 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

DATE
PROJECT: JJM, UP
150/12/12/22
DESIGNED CHECKED PAGE
TITLE 150KL 12m OHT
RKA DN
2
Mu/bd = 1.66 N/mm2
Percentage of steel required = 0.41 %
Area of steel required = 508.4 mm2/m
Minimum area of steel required 0.12/100 x 1000 x 160 = 192 mm2/m
Provide 12 dia @ 205 mm c/c as main steel
Provide 8 dia @ 235 mm c/c as distribution steel
Check for deflection
Ast required = 508.4 mm2/m
Ast provided = 551.69 mm2/m
pt provided = 0.44 %
Effective span = 3.23 m
fs = 0.58 x fy x Ast required = 267 N/mm2
Ast provided
Modification Factor = = 1.17
fig 4, IS:456
span / effective depth = 3.23 / 0.124 = 26.05
< 23x 1.17 = 26.91 OK
Check for shear
Maximum SF = 18.28 kN
Vu= 1.5 x 18.278 = 27.42 kN
Maximum shear stress = 27.42 x 1000/(1000 x 124) = 0.22 N/mm2
Permissible shear stress as per IS: 456-2000:
Percentage of steel provided = 0.44 %
Permissible shear stress = 0.46 N/mm2
OK

Load on Staircase Beam (Cantilever):


Reaction on beam Due to Dead Load of each flight:
(5.2 x 0.35 + 7.7 x 2.88 + 5.2 x 0.35)/2 = 12.91 KN/m
Reaction on beam Due to Live Load of each flight =
(3 x 0.35 + 3 x 2.88 + 3 x 0.35)/2 = 5.37 KN/m

Page 52 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Design of Bottom Ring Beam (staging top)


Grade of concrete ( f ck ) M30
Grade of steel ( f y ) Fe500
Dia of Tank c/c 7.16 m
Radius c/c 3.58 m
Height of Tank 4.03 m
Width of Beam 500 mm
Depth of Beam 700 mm
Thickness of Bottom Slab 250 mm
Thickness of Gallery 150 mm

Load Calculation
Weight of Tank 50 kN
Weight of Gallery 96.084 kN
Weight of bottom slab 251.52185 kN
weight of water 1812.08144 kN
Weight of live load on gallary 76.8672 kN
Self Weigth of Beam 196.721 kN
Total load on Beam 2483.3 kN
Factored load on Beam 3725 kN

a) Design of Tank Ring Beam


Let the width of ring beam 500 mm
Depth of ring beam 700 mm
Size of column supporting beam 400 mm
The beam is supporting on no. of column 6
2α 60 1.047 rad
βo 12.75 0.223 rad
α 30 0.524 rad

Bending moment coefficients are


At support λ - 0.089
At span λ + 0.045
Torsional moment coefficient is λ t 0.009
Load per meter run w 165.60 kN/m
Radius r 3.58 m
2
Max support moment = 2 α*w*r *λ + 197.81 kNm
2
Max span moment = 2α*w*r *λ - 100.01 kNm
2
Max torsional moment = 2α*w*r *λ t 20.00 kNm
Shear force at support (V o ) =Π*D*w/2*n 310.41 kN
Shear force at the section of maximum Torsion
V' = V 0 *(1-β o /α) 178.49 kN

Page 53 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Moment at face of column


2
wr *(-1+ α sinϴ + α cosϴ * cotα)
tan ϴ 0.06
ϴ 3.20 deg
0.06 rad
α sinϴ 0.029
α cosϴ * cotα 0.91

Moment at face of column M1 -138.6 kNm


Torsional moment at face of column
2
wr *(ϴ-α+α cosϴ - α sinϴ * cotα)
α cosϴ 0.5228
α sinϴ * cotα 0.0506

Torsional moment at face of column 9.35 kNm

Distance of max torsion from face of the supports


(π*D*βo/360)-r 0.60 m
< 0.612 Safe
Equivalent Bending Moment at face of column M2 = T ( 1+D/b) / 1.7
D= 700 mm
b= 500 mm
M2 13.20 kNm
Total Bending Moment at face of column M =M1+M2
M 151.81 kNm
Effective depth of beam required dreq 275.9 mm
Dia of reinf. 16 mm
Dia of Stirrups 10 mm
Clear Cover 45 mm
Effective Depth 612 mm
Equivalent Bending Moment (where torque is maximum) M2 = T ( 1+D/b) / 1.7
28.2 kNm
Area of Reinforcement for support moment at face of column
2
Mu/bd 0.81
Percentage of steel required 1198.319858
2
Ast,req 1198.319858 mm
2
Ast,min,reqd 520.2 mm
Area of Reinforcement for span moment
2
Mu/bd 0.53
Percentage of steel required as per SP-16 789.48
2
Ast,req 789.5 mm
2
Ast,min,reqd 520.2 mm
LONGITUDINAL REINFORCEMENT:
At Top:

Page 54 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Straight Bars Extra Bars


Dia of Bar 16 mm 16
2
Area of Bar 201.1 mm 201.1
Required no. of Bars at top 5.96 no's
Provided no of Bars 4 no's 3
2
Provided Area of Steel at top 804.2 mm 603.2
2
Total Provided Area of steel at top 1407.4 mm OK
At Bottom:
Straight Bars Extra Bars
Dia of Bar 16 mm 12
2
Area of Bar 201.1 mm 113.1
Required no. of Bars at bottom 3.93 no's
Provided no of Bars 4 no's 0
2
Provided Area of Steel at bottom 804.2 mm 0.0
2
Total Provided Area of steel at bottom 804.2 mm OK

At Bottom:
Provide 4- #16 tor through 3- #16 Extra
At Top:
Provide 4- #16 tor through 0- #12 Extra

Shear force at d from face of column


V = Vo - w (d+S/2) 175.9 kN
Equivalent shear at section of maximum torsion
Ve = V'+1.6*T/b 242.5 kN
Equivalent Shear Stress
2
τve =1.5Ve/(bd) 1.19 N/mm
2
Area of Steel at Support 1407.4 mm
pt 0.46
From table 19 of IS 456, permissible shear stress of concrete τc
2
0.52 N/mm
Shear Capacity of section 159120 N
Net Shear 16824 N
TRANSVERSE REINFORCEMENT:
Dia of Stirrups 10 mm
No of Legs 2
Area of shear reinforcement as per Clause 41.4.3 of IS 456 -2000
Spacing should be lesser of the following
1). Asv/Sv = T/(b 1*d1*(0.87fy)+ Vu/(2.5d1 (0.87fy)
Dia of main reinforcement 16 mm
Dia of Stirrups 10 mm
Cover 45 mm
T 20002784.07 Nmm
V 178485.43 N

Page 55 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

b1 374 mm
d1 574 mm
2
0.87f y 435 N/mm
2
Asv 157 mm
Asv/Sv 0.50
Sv 313.9 mm
2). Sv = (Asv*0.87f y) /(b*( τve-τc) 204.3 mm
Spacing is lesser of above two cases 204.3 mm
Say 100 mm

Ductile Detailing of Beam:


As per IS 13920 :2016
The first hoop shall be at a distance not exceeding 50 mm from the joint face. Vertical
Width of beam 500 mm
Depth of beam 700 mm
Clear cover 45 mm
Dia of Hoop 10 mm
Dia of main bar provided 16 mm
Effective depth 612 mm
The spacing of hoops over a length of 2d at either ends of a beam shall not exceed
a) d/4 153 mm
b) 8 times the diameter of the smallest longitudinal bar 128 mm
c) 100 mm 100 mm
Min (153,128,100) 100 mm
Provide spacing at support 100 mm
Length of Confining steel from face of the support, 2d 1224 mm
Say 1250 mm
Stirrups:
Hence Provide 2L - Y10 stirrups @ 100 mm c/c throught

Side Face Reinforcement:


Providing 0.1% Side face reinforcement.
2
SFR required 350 mm
Dia of bar provided 10.0 mm
Required No. of bar 4.5
Say 4.0
Provide side face reinforcement : 4-10 mm 2 No.s on each face

Check for Crack Width for Bending Moment


As Per IS 3370-2009 (Part II)
Crack Width Calculation for Bottom Ring Beam(B.R.B)
1) Sectional Properties:
Width, b 500 mm
Depth, d 700 mm

Page 56 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Clear Cover, Cmin 45 mm


Dia of bar, dc 16 mm
Spacing, S 97.5 mm

Effective Depth, d 645.00 mm


2
Area of Steel, Ast 1407.4 mm
Total Cover, ec 53 mm

Grade Of Concrete, fck M30


2
30 N/mm
Grade Of Steel, fy Fe500
2
500 N/mm
2
Elastic Modulus Of Concrete, Ec = 5000 √fck 27386.13 N/mm
Elastic Modulus Of Steel, Es 200000.00000 N/mm 2
Modular Ratio, m = Es/Ec 7.3030
Reinforcement ratio factor, p = Ast/bd 0.004
Maximum Moment, Ms 151.81 kNm

2) Depth of Neutral Axis:


From The Method of The Transformed Section,
C=T
b*x*x/2 = m*As*(d-x)
By solving the above equation for roots,
x/d = -mp+√(mp*(mp+2)) 0.22
x 143.58 mm
Lever Arm, z = d-(x/3) 597.14 mm

3) Induced Stress in the Concrete & Reinforcement:

For the crack width formula to be valid, the compressive stress in concrete and the
tensile stress in steel
Concrete: fc ≤ 0.45 fck
Steel: fs ≤ 0.8 fy

Page 57 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Stress induced in Concrete can be calculated as


Limiting Moment, Ms= C*Lever Arm= (x*b*fc /2) * z
2
fc = 2Ms/(x*b*z) 7.08 N/mm
2
Concrete: fc ≤ 0.45 fck 13.5 N/mm
Hence Safe

Stress induced in Reinforcement can be calculated as


Limiting Moment, Ms = T*Lever Arm = As*fs* z
2
fs = Ms/(As*z) 180.6 N/mm
2
Steel: fs ≤ 0.8 fy 400 N/mm
Hence Safe

Hence as per Clause No. 4.4.3.1 of IS 3370:2009 (Part II), Check for Crack width is not Required

4) Nominal Strain ε1 :
From Strain Diagram,

ϵ1 0.001002217

5) Strain Hardening due to Stiffening effect, ε2 :


As per Annexure B of IS 3370:2009 (Part II)

For limiting design surface crack width of 0.2 mm

ϵ2 0.000298007

Hence there will be crack

6) Design Crack Width, w:

Average strain at the level where crack is being considered,


εm = ε 1 - ε 2 0.00070421

Distance from considered point to the surface of the nearest


√((S/2)²+ec²) - (dc/2)
longitudinal bar, acr
acr 51.26 mm

Page 58 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Design Surface Crack width,

w 0.11 mm
< 0.2 mm
Hence the design crack width is with in the allowable limit.

Page 59 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

STAAD SPACE -- PAGE NO. 33

SUMMARY OF REINF. AREA (Sq.mm)


----------------------------------------------------------------------------
SECTION 0.0 mm 895.0 mm 1790.0 mm 2685.0 mm 3580.0 mm
----------------------------------------------------------------------------
TOP 235.62 235.62 235.62 275.33 499.91
REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm)

BOTTOM 300.38 235.62 235.62 235.62 235.62


REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm)
----------------------------------------------------------------------------

SUMMARY OF PROVIDED REINF. AREA


----------------------------------------------------------------------------
SECTION 0.0 mm 895.0 mm 1790.0 mm 2685.0 mm 3580.0 mm
----------------------------------------------------------------------------
TOP 3-16d 3-16d 3-16d 3-16d 3-16d
REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s)

BOTTOM 3-16d 3-16d 3-16d 3-16d 3-16d


REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s)

SHEAR 2 legged 8d 2 legged 8d 2 legged 8d 2 legged 8d 2 legged 8d


REINF. @ 170 mm c/c @ 170 mm c/c @ 170 mm c/c @ 170 mm c/c @ 170 mm c/c
----------------------------------------------------------------------------

============================================================================

============================================================================
IS-456 L I M I T S T A T E D E S I G N
B E A M N O. 25 D E S I G N R E S U L T S

M30 Fe500 (Main) Fe500 (Sec.)

LENGTH: 3580.0 mm SIZE: 300.0 mm X 500.0 mm COVER: 30.0 mm

SUMMARY OF REINF. AREA (Sq.mm)


----------------------------------------------------------------------------
SECTION 0.0 mm 895.0 mm 1790.0 mm 2685.0 mm 3580.0 mm
----------------------------------------------------------------------------
TOP 659.78 377.91 235.62 235.62 235.62
REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm)

BOTTOM 235.62 235.62 235.62 235.62 367.93


REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm)
----------------------------------------------------------------------------

Page 60 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

STAAD SPACE -- PAGE NO. 114

============================================================================

============================================================================
IS-456 L I M I T S T A T E D E S I G N
C O L U M N N O. 44 D E S I G N R E S U L T S

M30 Fe500 (Main) Fe500 (Sec.)

LENGTH: 3850.0 mm CROSS SECTION: 400.0 mm dia. COVER: 45.0 mm

** GUIDING LOAD CASE: 154 END JOINT: 26 SHORT COLUMN

REQD. STEEL AREA : 1192.99 Sq.mm.


REQD. CONCRETE AREA: 124470.72 Sq.mm.
MAIN REINFORCEMENT : Provide 6 - 16 dia. (0.96%, 1206.37 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. circular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2127.73 Muz1 : 86.60 Muy1 : 86.60

INTERACTION RATIO: 0.99 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 154
END JOINT: 26 Puz : 2132.56 Muz : 85.66 Muy : 86.09 IR: 1.00
============================================================================

============================================================================
IS-456 L I M I T S T A T E D E S I G N
C O L U M N N O. 45 D E S I G N R E S U L T S

M30 Fe500 (Main) Fe500 (Sec.)

LENGTH: 3887.5 mm CROSS SECTION: 400.0 mm dia. COVER: 40.0 mm

** GUIDING LOAD CASE: 154 END JOINT: 27 SHORT COLUMN

Page 61 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Ductile Detailing of Beam

As per IS 13920: 2016

The first hoop shall be at a distance not exceeding 50 mm from the joint face. Vertical hoops at
the same spacing as above, shall also be provided over a length equal to 2d on either side of a
section where flexural yielding may occur under the effect of earthquake forces. Elsewhere, the

Width of Beam 300 mm


Depth of Beam 500 mm
Clear Cover 45 mm
Dia of Hoop 8 mm
Dia of Main bar provided 16 mm
Effective Depth 455 mm

The spacing of hoops over a length of 2d at either ends of a beam shall not exceed
d/4
8 times the diameter of the smallest longitudinal bar

(a) d/4 113.75 mm


(b) 8 times the diameter of the smallest longitudinal bar 128 mm
( c) 100 mm 100 mm

The spacing of hoops over a length of 2d at either end of a beam shall be provided is
Min (113.75,128,100) 100 mm
Provide spacing at support 100 mm

Length of Confining steel from face of the support, 2d 910 mm


Say 1000 mm

Elsewhere, the beam shall have vertical hoops at a spacing not exceeding d/2
d/2 227.5 mm
Elsewhere, the beam shall have vertical hoops at a spacing of 150 mm
Stirrups
Hence provide 2L - Y8 stirrups @ 100 mm c/c at supports at a distance of 1000 mm from face of
the column and provide 2L - Y8 stirrups elsewhere @ 150mm c/c

Ductile Detailing as per IS 13920 : 2016


Confining Links in Circular Column :

Page 62 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Column of Section 450 mm dia


Clear Cover 45 mm
Dia of Hoops 10 mm
Provided Dia of smallest longitudinal bar 0 mm
Provided No. of smallest Dia longitudinal bar 16 mm
Clear Height of column 3350 mm
h = Longer Dimension of Rectangular confining hoop measured to its outer
face
(It shall not exceed 300 mm)
The Size of Core D k 380 mm

Spacing of Hoops :
Spacing not more than following :
1.) 1/4 of Minimum Member Dimension 112.5 mm
2.) 6 times the dia smalest longitudinal reinforecement 96 mm
3.) 100 100 mm
Provide Spacing of Hoops, S 90 mm

2
Area of Concrete Core A k 113354 mm
2
Gross area of Column C/S A g 158962.5 mm
Grade of Concrete f ck 30 MPa
Grade of Steel f y 500 MPa
1.) Area of C/S of bar forming circular hoop is A sh = 0.09 Sv Dk fck/fy ((Ag/Ak)-1)
2
Ash = 0.09*90*380*(30/500)*((158962.5/113354)-1 74.31 mm
2.) Area of C/S of bar forming circular hoop is A sh = 0.024 Sv Dk fck/fy
2
Ash = 0.024*90*380*(30/500) 49.248 mm
2
Maximum of 1 and 2 74.31 mm
2
Provided C/S of bar forming hoop 78.5 mm
Provided hoop bar of dia 10 mm is O.K
Thus Circular Hoops of Dia 10 mm at a spacing of 90mm c/c will be adequate.

The special confining reinforcement Lo is not lessthan following


1.) larger lateral dimension of the member 450 mm
2.) 1/6 of clear span of member 558.3333 mm
3 450 450 mm
Provide Length of confining reinforcement, L o 500 mm

Hencce Provide the confining reinforcement over a height of 500 mm from face of the Joint.

Transverse Reinforcement:
Diameter of Lateral ties:
The dia of lateral ties shall not be less than the following,

Page 63 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

1.) 1/4 th of dia of largest longitudinal bar 4 mm


2.) 6 mm 6 mm
Required dia of lateral ties (Maximum of 1 & 2) 6 mm
However Provide Dia of Lateral tie 8 mm
Spacing of Lateral ties:
Shall not be more than least of the following
1.) The least lateral dimension of compression member 450 mm
2.) 16 times the smallest dia of longitudinal reinforcement 256 mm

Required Pitch of lateral ties 256 mm


However Provide Pitch of Lateral tie 150 mm
Provide 8 dia ties @150 mm c/c through out

Page 64 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

400

8mm @ 150
c/c
G.L. 00 G.L. 00 circumferentially

8#-16Ø
CL A B C D
1790 3580 1790

VENTILATOR FOR
ROOF SHEET AIR RELEASE
4#-10Ø SFR 4#-20Ø HOOPS

2000
HANDRAIL (2 ON EACH FACE)

10Ø @ 200 c/c


10Ø- 2 LEGGED STIRRUPS 3 C1 C2
(HOOPS)

600
RB

450
3#-16Ø (2600 LONG)

3100
250
4#-20Ø
INLET
OVERFLOW
CAGE LADDER
Ø7160 12Ø @ 200 C/C 100 MM THICK
MEASURED AT OUTER P.C.C. IN (1:4:8) 2 C3 C4
EDGE OF BEAM
TANK WALL SHEET 770 500 930
2200 2400

3100
4600
EL +12 m RB

250
6th Landing
CL
RING BEAM
SECTION OF RAFT SLAB (4-4)
1 C5 C6

EL +10 m 8mm @ 150mm c/c radials


5th Landing
LIFTING HOOK
PRECAST SLAB
RL+7.95

200
EL +8 m
4th Landing
3rd BRACE 10Ø@ 200 c/c HOOPS
F.G.L. 0.30

300
N.G.L. 0.00 12Ø @ 200 c/c
MEASURED AT OUTER

H
EDGE OF BEAM
3rd Landing 12 MM THICK
EL +6 m PLASTER IN CM 1:6 10Ø @ 200 c/c HOOPS BALCONY SLAB REINFORCEMENT LAYOUT - 12 M

H
RL+4.1
EL +4 m
2nd Landing
2nd BRACE 100 (TYP.) LxB 230
PCC
230 DETAILS OF BRICK
VALVE CHAMBER
EL +2.0 m
1st Landing

+0.3 m +0.3 m
RL+0.250
+0 m FGL FGL +0 m
NGL NGL F.G.L. 0.30
N.G.L. 00
1st BRACE
PART REINF. PLAN OF RAFT SLAB
ANNULAR
RAFT FOOTING
BRICK VALVE
100 thk P.C.C
CHAMBER
LEVELLED EARTH CHECQUERED FLOOR
OVER
100 THICK P.C.C.

SECTION 1-1
115 BRICK WALL
A B C D

250
IN CM 1:6
230 BRICK
WALL IN CM 1:6
1790 3580 1790 M15 P.C.C.
100 THICK
100 (TYP.) 230 300 115

4
DETAILS OF DRAIN 0 FOR APPROVAL DKN AP
REV. DATE DESCRIPTION DESIGN DRAWN CHKD APPD
3 C1 C2
PROJECT: CONSTRUCTION OF WATER SUPPLY SCHEME DISTRICT-SIDDHARTH NAGAR
WITH RELEVANT WORKS INCLUDING COMMISSIONING AND OPERATION
AND MAINTENANCE
B 2 3 C
FB
4
3100

+0 m NGL CLIENT: EXECUTIVE DIRECTOR


State Water & Sanitation Mission
Namami Gange & Rural Water Supply Department
Government of Uttar Pradesh
1 1 Lucknow, Uttar Pradesh - 226001
2 C3 C4 8-T16 4-T20 HOOPS
4-T20 HOOPS
8-T16 CONTRACTOR:
4-T20 4-T20 VSA_SCL JV
STP 2L-T10 STP 2L-T10
100 100 100 100 100 100 100 100 100 100 100 150 150 150 150 150 150 150 150
SFR 2-T10EF
SFR 2-T10EF
3-T16
3100

4-T20 4-T20

CONSULTANT:
4-T20 HOOPS 4-T20 HOOPS
4-T20 HOOPS
SECTION 2-2(FB) SECTION 3-3(FB)
FOUNDATION +3-T16 (2600mm LENGTH) MATSHUI ENGINEERING
+3-T16 (2600 mm LENGTH)
RING BEAM SERVICES PVT. LTD.
(500x700) 2 3 RELEASE STATUS DATE DATE NAME
1 INNER C5 C6
PRELIMINARY DESIGN 19-11-22 DKN TITLE:
CANTILEVER STRUCTURAL DRAWING OF OVER HEAD TANK (150KL, - 12 m
PART L-SECTION OF FOUNDATION RING BEAM FOR INFORMATION DRAWN 19-11-22 AP STAGING) FOR WATER SUPPLY SCHEME AT FARENDA,KHUNIYAON
FB1:500x700 BLOCK,SIDDHARTH NAGAR DISTRICT,U.P.
OUTER CANTILEVER
400Ø COLUMNS FOR APPROVAL FORAPPDT CHECKED . .
(6 NOS.)
FOR CONSTRUCTION APPROVED . .
PLAN AT FOUNDATION LEVEL
AS-BUILT DEPARTMENT: CIVIL (DESIGNS) DRG. NO : JJM/ZONE4/150-12 SCALE- NTS REV- R0 SIZE- A2 SHEET- 1 OF 3

Page 65 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

A B C D ISA 50x50x6 POST


20Ø GI PIPE
1790 3580 1790 T8@235 C/C

360
50X50X6 MS ANGLE
400 /C T8@235 C/C
5C
23 500.0 450
20Ø GI PIPE ISA 50x50x6 POST @
RB T8

360
20 DIA G.I. PIPE RAILING 0
3 C1 C2 45

160
20Ø GI PIPE
LB
RB

360
3100
T8@205 C/C
INSERT PLATE 286.7
(TYP)
150 THK T8@235 C/C

SLAB
150 THK
2 C3 C4

200
FIXING DETAILS OF RAILING
/C

3100
BRACES 5C
23 /C

16
@ 5C

0
[300X500] 100 T8 23
Lo

0 @
50 45 T8

CONFINEMENT
1 C5 C6 T8@235 C/C

10Ø STR.@
64

ZONE
32

90 C/C

100
50
500
T8@235 C/C
500.0

100 0
45 T12@205 C/C

160
8Ø STR.@

Lo
90 C/C

75 6
BOTTOM SLAB REINFORCEMENT LAYOUT - 12 M (250 thick) 100X100X6MM THK LB
INSERT PLATE
T8@235 C/C
L2/4

1-8Ø LUGS
5 5 450
25

A B C D T8@235 C/C 7

588(ANCHORAGE)
1790 3580 1790
TYPICAL DETAILS
1000 400
OF INSERT PLATE DETAILS OF STAIRCASE
350
RB 4-T12
8Ø STR. @ 150 C/C

3 4-T12
C1 C2
LAP ZONE

350
STP 2L-T8

MID ZONE

588(ANCHORAGE)
3-T12 3-T12
L2

RB
6 6

3100
5-2L-T8 SECTION 7-7
@235 C/C

2 C3 C4 7

LB:350x350
STAIRCASE LANDING BEAM DETAIL

3100
L2/4
8Ø @ STR.

BRACES 1 C5 C6
90 C/C

[300X500]
Lo

CONFINEMENT

+0 m
NGL
ZONE
500
10Ø @ STR.

10Ø @ STR.
90 C/C

90 C/C

TOP SLAB REINFORCEMENT LAYOUT - 12 M (250 thick)


L1/4

Lo

R.C.C. DETAIL OF LANDING


10Ø @ STR.

L1/2
90 C/C

L1

10Ø @ STR. 10Ø @ STR.

SLAB AT BALCONY +12 m


FB
90 C/C

[500X700]
L1/4
10Ø @ STR.

A B C D
90 C/C

90 C/C

1790 3580 1790


Lo

0 FOR APPROVAL DKN AP


700

REV. DATE DESCRIPTION DESIGN DRAWN CHKD APPD


350

RL-2.0 PROJECT: CONSTRUCTION OF WATER SUPPLY SCHEME DISTRICT-SIDDHARTH NAGAR


Lo = 500 mm 3 C1 BB C2 WITH RELEVANT WORKS INCLUDING COMMISSIONING AND OPERATION
AND MAINTENANCE
CLIENT: EXECUTIVE DIRECTOR
DETAIL OF COLUMN
3100

State Water & Sanitation Mission


BB

BB

Namami Gange & Rural Water Supply Department


Government of Uttar Pradesh
Lucknow, Uttar Pradesh - 226001
2 C3 C4
CONTRACTOR:
VSA_SCL JV
3100

BB
BB

CONSULTANT:
8-T16 8-T16
8Ø RINGS @ 90
1 C5 BB C6 MATSHUI ENGINEERING
8Ø RINGS @ 150
C/C
C/C
SERVICES PVT. LTD.
RELEASE STATUS DATE DATE NAME
400 400 PRELIMINARY DESIGN 19-11-22 DKN TITLE:
STRUCTURAL DRAWING OF OVER HEAD TANK (150KL, - 12 m
SECTION 5-5 SECTION 6-6 FOR INFORMATION DRAWN 19-11-22 AP STAGING) FOR WATER SUPPLY SCHEME AT FARENDA,KHUNIYAON
FOR APPROVAL FORAPPDT CHECKED . .
BLOCK,SIDDHARTH NAGAR DISTRICT,U.P.

PLAN SHOWING ARRANGEMENT OF STAIR STEPS FOR CONSTRUCTION APPROVED . .

AS-BUILT DEPARTMENT: CIVIL (DESIGNS) DRG. NO : JJM/ZONE4/150-12 SCALE- NTS REV- R0 SIZE- A2 SHEET- 2 OF 3

Page 66 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

A 8 B 9 C 8 D

1100(ANCHORAGE)

1100(ANCHORAGE)
704(ANCHORAGE)

704(ANCHORAGE)
400 400 400 400 A B C D
0.33 x L1 0.33 x L1 SFR 2-T10EF 4-T16 SFR 2-T10EF
3-T16 4-T16 1790 3580 1790
For GB1 400 400
4-T16 For GB1 For GB2 4-T16 STP 2L-T10 STP 2L-T10
3-T16 4-T16 3-T16 1.0 M WIDE BALCONY

250

250

250

250
2-T10EF 2-T10EF 2-T10EF RB
B4
3 C1 C2
880(ANCHORAGE)

880(ANCHORAGE)
1100(ANCHORAGE)

1100(ANCHORAGE)

700

700
3-T16 3-T16 4-T16 3-T16 3-T16
4-T16 4-T16
4-T16 4-T16 RB RB

3100
T10 2L-T10 T10
@100 C/C @150 C/C @100 C/C
0.15 x L1 L1 0.15 x L1 SECTION 8-8 (GB1/GB2) SECTION 9-9 (GB1/GB2)
GB1
GRID BEAM (GB1/GB2) 400X700

6200
2 C3 C4

8 4-T16 9 8 B 10 11 C 10 7160
STP 2L-T10 4-T16

GB2
STP 2L-T10

GB2
3-T16

3100
500 500 400 3348.9 40 0
SFR 2-T10EF RB
900 900 900 900 RB
150

150
4-T16
250

250
3-T16 EXTRA 1 C5 B5 C6
RB
700

700
SFR 2-T10EF
GB 2-T10EF GB
4-T16 4-T16

1000 1000 4-T16 1000 1000

2L-T10 2L-T10 2L-T10


SECTION 10-10 (RB) SECTION 11-11 @100 C/C @150 C/C @100 C/C
RING BEAM & GRID BEAM LAYOUT at 12m level
10 11 10
500
T8@150 C/C HOOPS
Circular Ring Beam (RB) :500x700 T8@150 C/C HOOPS
400
500 400 1000
1000
150

150
250

T12@105 C/C T10@150 C/C T8@150 C/C RADIAL BARS


T8@150 C/C RADIAL BARS

TOP RING BEAM (500x700) GRID BEAM (400x700) GRID BEAM (400x700) TOP RING BEAM (500x700)
DETAIL OF SLAB

A B C D
2 13 14 13 3
648(ANCHORAGE)

648(ANCHORAGE)
1790 3580 1790
648(ANCHORAGE)

648(ANCHORAGE)
40 0 400
3180
800 800

2-T16 2-T16
BB 2-T16 2-T16
3 C1 C2
1-T10EF 0 FOR APPROVAL DKN AP
REV. DATE DESCRIPTION DESIGN DRAWN CHKD APPD
648(ANCHORAGE)

648(ANCHORAGE)
648(ANCHORAGE)

648(ANCHORAGE)
3100

BB
BB

2-T16 2-T16 PROJECT: CONSTRUCTION OF WATER SUPPLY SCHEME DISTRICT-SIDDHARTH NAGAR


2-T16 2-T16 WITH RELEVANT WORKS INCLUDING COMMISSIONING AND OPERATION
2L-T8 2L-T8 2L-T8 AND MAINTENANCE
@100 C/C @150 C/C @100 C/C
CLIENT: EXECUTIVE DIRECTOR
2 C3 C4 1000 1000 State Water & Sanitation Mission
Namami Gange & Rural Water Supply Department
Government of Uttar Pradesh
13 14 13 Lucknow, Uttar Pradesh - 226001
3100

BB
BB

Brace Beam (BB):300x500 CONTRACTOR:


VSA_SCL JV
BB
1 C5 C6 300 300
CONSULTANT:
2-T16 MATSHUI ENGINEERING
2-T16 EXTRA 2-T16 SERVICES PVT. LTD.
STP 2L-T8 STP 2L-T8 RELEASE STATUS DATE DATE NAME
500

500

SFR 1-T10EF
SFR 1-T10EF PRELIMINARY DESIGN 19-11-22 DKN TITLE:
STRUCTURAL DRAWING OF OVER HEAD TANK (150KL, - 12 m
2-T16 EXTRA STAGING) FOR WATER SUPPLY SCHEME AT FARENDA,KHUNIYAON
FOR INFORMATION DRAWN 19-11-22 AP
2-T16 2-T16 BLOCK,SIDDHARTH NAGAR DISTRICT,U.P.
BEAM PLAN AT BRACE LEVEL FOR APPROVAL FORAPPDT CHECKED . .

SECTION 13-13 (BB) SECTION 14-14 (BB)


(AT +0.25, +4.1,&+7.95 m
FOR CONSTRUCTION APPROVED . .

AS-BUILT DEPARTMENT: CIVIL (DESIGNS) DRG. NO : JJM/ZONE4/150-12 SCALE- NTS REV- R0 SIZE- A2 SHEET- 3 OF 3

Page 67 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 68 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 69 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 70 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 71 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 72 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 73 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 74 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 75 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 76 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 77 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 78 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 79 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 80 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 81 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 82 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 83 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 84 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 85 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 86 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 87 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 88 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 89 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 90 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 91 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 92 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 93 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 94 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 95 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 96 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 97 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 98 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 99 of 107
FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 100 of 107


FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 101 of 107


FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 102 of 107


FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 103 of 107


FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 104 of 107


FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 105 of 107


FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 106 of 107


FARENDA,KHUNIYAON BLOCK,SIDDHARTH NAGAR DISTRICT,U.P. 150_12

Page 107 of 107

You might also like