0% found this document useful (0 votes)
2 views

SOURIAU Conectores

The UTO Series features robust metal and shielded connectors designed for various applications including energy, robotics, and telecommunications. Key benefits include IP68/69K water resistance, EMI shielding, and corrosion resistance, making them suitable for dynamic environments. The series offers a range of contact configurations and technical specifications to meet diverse industrial needs.

Uploaded by

omur.cat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views

SOURIAU Conectores

The UTO Series features robust metal and shielded connectors designed for various applications including energy, robotics, and telecommunications. Key benefits include IP68/69K water resistance, EMI shielding, and corrosion resistance, making them suitable for dynamic environments. The series offers a range of contact configurations and technical specifications to meet diverse industrial needs.

Uploaded by

omur.cat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 188

UTO SERIES

Robust Metal & Shielded Connector


UTO Series |

Overview
Contents

Overview Contacts
Typical Applications ........................................... 06 Description ........................................................ 126

Connector
Features & Benefits ........................................... 07 Contact Plating Selector Guide ......................... 127
Range Overview ................................................ 08 Contact Selector Guide ..................................... 128
Layouts .............................................................. 10 Packaging .......................................................... 128
General Technical Characteristics ...................... 12 Crimp Contacts ................................................. 129
#16 Coaxial Contacts ........................................ 131
PCB Contacts .................................................... 132
Fiber Optic Contacts ......................................... 133

Connector Technical Information

Contacts
Cable Assembly ................................................. 16 Tooling ............................................................... 139
2 contacts + ground .......................................... 20 Crimping Instructions ........................................ 140
3 contacts + ground .......................................... 28 Handle & Interchangeable Heads ..................... 142
4 contacts .......................................................... 32 Extraction Tools ................................................. 143
Dimensions Overmoulded Harnesses ............... 143

Technical Information
6 contacts .......................................................... 40
6 contacts + ground .......................................... 48 Assembly Instructions ........................................ 144
8 contacts .......................................................... 52 Mated Connector Length .................................. 153
10 contacts ........................................................ 60 Rated Current & Working Voltage ..................... 155
12 contacts ........................................................ 64 Shielding Effectiveness/Corrosion ..................... 156
19 contacts ........................................................ 72 UL94 + UL1977 .................................................. 157
23 contacts ........................................................ 80 IEC 61984 with IP Code Explanation ................. 160
26 contacts ........................................................ 84 IEC 61140 Explained ......................................... 162
28 contacts ........................................................ 88 What is NEMA Rating ? ..................................... 163
30 contacts ........................................................ 92 Ethernet for the Layman .................................... 164
32 contacts ........................................................ 96
35 contacts ........................................................ 100 Appendices
38 contacts ........................................................ 104 #16 Coaxial Contacts/Cabling Notices ............. 168
Appendices

41 contacts ........................................................ 108 Glossary of Terms .............................................. 175


48 contacts ........................................................ 112 Drilling Pattern .................................................. 176
55 contacts ........................................................ 116 Discrimination/Keying Methods ........................ 180
61 contacts ........................................................ 120 Part Number Index ............................................ 181

3
UTO SERIES

© 2013 SOURIAU - SOURIAU is a registered trademark


UTO Series

Overview
Typical Applications ................................................................................................. 06

Features & Benefits ................................................................................................. 07

Range Overview ...................................................................................................... 08

Layouts .................................................................................................................... 10

General Technical Characteristics ............................................................................ 12

5
UTO Series | Overview

Typical Applications

© Volodymyr Kyrylyuk / Fotolia


© Rainer Plendl / Fotolia
© Vibe Images / Fotolia

Energy - Power Robotics - Machine tools Building Automation & Control

© Sergey Milovidov / Fotolia


© SOURIAU

Instrumentation measurement Off road - Mining - Railway


© Olivier Tuffé / Fotolia

Telecom - Data infrastructure

6
UTO Series | Overview

Features & Benefits

IP68/69K Dynamic Mated


Ideal for outdoor and indoor dynamic applications requiring
WATER continuous underwater immersion, routine pressure washing
PROOF and dust protection.

Overview
EMI Shielded
65 dB at 100 Mhz: Qualified and compatible to be used in
Signal electromagnetic radiation areas and ensures proper signal integrity and
integrity transmission.

Salt Spray 48 & 96 Hours


Designed to withstand climate ingress and exposure to salt spray
Corrosion or corrosive atmospheres while still maintaining mechanical and
resistant electrical functionality.

1/3 Bayonet Coupling


With only 1/3 twist of the bayonet coupling system, connectors are
quick mated with audible "click" and tactile feel to confirm proper mating.
mating This mating feature eliminates connection uncertainty and reduces time
and labor during installation.

Mixed Power & Signal Layouts


Power supply and signal transmission can be combined in a
Cost unique interconnect solution to reduce system complexity and
savings minimize component/installation costs.

7
UTO Series | Overview

Range

Single Wire
Sealing

Straight
Strain Relief

Right Angle
Strain Relief

Choice of Crimp Contacts


• machined
• stamped and formed
Short Cable • coaxial
Gland • fiber optics Plug

Long Cable
Gland

UTO Series

Heat Shrink Boot


Adapter

Sealed: IP68/69K
Shielded
Corrosion resistant
UL compliant

Overmoulded

8
UTO Series | Overview

Overview

Overview
Single Wire
Sealing

Straight
Receptacle Choice of Crimp Contacts
• machined
Strain Relief
• stamped and formed
• coaxial
• fiber optics

PCB Contact
Heat Shrink Boot
Adapter

9
UTO Series | Overview

Layouts (Electrical parameter according to IEC 61984 & IEC 61140)

Shell size Contact #16 (Ø 1.6) Contact #20 (Ø 1.0) Contact #8 (Ø 3.6) Mixed Power

103 104* 106* 102W2 103W3


16A 150V 13A 150V 7A 80V 25A 200V 5A 40V
2 contacts 4 contacts 6 contacts 4 contacts 6 contacts
+ground 4xØ1.6 (#16) 6xØ1.0 (#20) 2xØ2.4 (#12) 3xØ1.6 (#16)
3xØ1.6 (#16) 2xØ1.0 (#20) 3xØ1.0 (#20)
10

Page 20 Page 36 Page 44 Page 32 Page 40

124 128 1210*


16A 150V 10A 125V 6A 40V
3 contacts 8 contacts 10 contacts
+ground 8xØ1.6 (#16) 10xØ1.0 (#20)
4xØ1.6 (#16)
12

Page 28 Page 52 Page 60

147 1412 1419 142G1 148


16A 150V 10A 150V 5A 40V 40A 250V 17A 230V
6 contacts 12 contacts 19 contacts 2 contacts 8 contacts
+ground 12xØ1.6 (#16) 19xØ1.0 (#20) +ground 4xØ2.4 (#12)
7xØ1.6 (#16) 3xØ3.6 (#8) 4xØ1.6 (#16)

Page 48 Page 64 Page 72 Page 24 Page 56


14
1492
10A 150V
12 contacts
12xØ1.6 (#16)

Page 68

1619* 1626
9A 150V 4A 40V
19 contacts 26 contacts
19xØ1.6 (#16) 26xØ1.0 (#20)

16

Page 76 Page 84

* Ethernet compatible see page 168 & 169

10
UTO Series | Overview

Contacts #16: Contacts #20: Contacts #8: Contacts #12:


from AWG 30 to 14, from AWG 26 to 18, from AWG 16 to 8, fromAWG 22 to 12,
0.05 to 2.5 mm² 0.13 to 0.93 mm² 1.5 to 10 mm² 0.13 to 4 mm²

Shell size Contact #16 (Ø 1.6) Contact #20 (Ø 1.0)

1823 1832
8A 150V 4A 50V
23 contacts 32 contacts
23xØ1.6 (#16) 32xØ1.0 (#20)

18

Overview
Page 80 Page 96

2028 2030 2041


7A 150V 7A 150V 8A 80V
28 contacts 30 contacts 41 contacts
28xØ1.6 (#16) 30xØ1.6 (#16) 41xØ1.0 (#20)

20

Page 88 Page 92 Page 108

2235 2238 2255


6A 150V 6A 150V 3A 80V
35 contacts 38 contacts 55 contacts
35xØ1.6 (#16) 38xØ1.6 (#16) 55xØ1.0 (#20)

22

Page 100 Page 104 Page 116

2448 2461
6A 160V 3A 80V
48 contacts 61 contacts
48xØ1.6 (#16) 61xØ1.0 (#20)

24

Page 112 Page 120

11
UTO Series | Overview

General technical characteristics

Materials Environmental Electrical


• Shell: Zinc alloy • Operating temperature: • In accordance with:
from -40°C to +105°C - UL 1977: Certificate ECBT2
• Backshells and cable glands: Brass 40/100/21 per NFF 61-030 File number: E169916
- CSA C22.2: Certificate ECBT8
• Coupling ring: Aluminum alloy • Flammability rating: File number E169916
UL94 V-0
• Coupling spring: Spring stainless steel I2F3 according to NFF 16101 and NFF 16102 • Also see pages 10 & 11

• Insert: Glass-filled thermoplastic • Salt spray:


per MIL-STD-202 method 101
• Contacts: See page 129 - 48 h (standard version)
- 96 h (black anodized coupling ring)
Higher salt spray resistance (200/500 h)
Mechanical
• Halogen free
upon request
• Durability:
• RoHS compliant & conforms to the Chinese 500 matings & unmatings per MIL-C-26482
standard SJ/T1166-2006 • Sealing:
(Chinese RoHS equivalent) Per IEC 60529/DIN 40050: Dynamic IP67 / IP68
• Vibration resistance:
(under 10 m of water during 1 week) / IP69K in
55-2000 Hz, acceleration 15 g per
mated condition and in combination with
Mil-C-26482 (Series 1)
sealed backshell.
10-100 Hz, acceleration 2 g per NFF61030
• Fluid resistance:
• Thermal shock:
- Gas and oil
5 cycles 30 min. from -40°C to 105°C
- Mineral oil
per MIL-STD-202 method 207
- Acid bath
- Basic bath
• Mechanical shock:
50 g, 11 ms period per Mil-C-26482 (Series 1)
• Shielding effectiveness:
30 g, 18 ms period per NFF61030
65 dB at 100 MHz

12
UTO Series | Overview

Overview

13
UTO SERIES

© 2013 SOURIAU - SOURIAU is a registered trademark


UTO Series

Connector
Upgrade of the UTO Series ..................................................................................... 16
Cable Assembly ....................................................................................................... 17
2 contacts + ground
103: 10A 500V.................................................................... 20
142G1: 44A 600V.................................................................... 24
3 contacts + ground
124: 16A 500V.................................................................... 28
4 contacts
102W2: 20A 500V.................................................................... 32
104*: 10A 500V.................................................................... 36
6 contacts
103W3: 5A 250V.................................................................... 40
106*: 5A 250V.................................................................... 44
6 contacts + ground
147: 10A 500V.................................................................... 48
8 contacts
128: 10A 500V.................................................................... 52.
148: 25A 250V.................................................................... 56
10 contacts
1210*: 5A 250V.................................................................... 60
12 contacts
1412: 10A 500V.................................................................... 64.
1492: 10A 500V.................................................................... 68
19 contacts
1419: 5A 250V.................................................................... 72
1619*: 9A 500V.................................................................... 76
23 contacts
1823: 8A 500V.................................................................... 80
26 contacts
1626: 4A 250V.................................................................... 84
28 contacts
2028: 5A 500V.................................................................... 88
30 contacts
2030: 5A 500V.................................................................... 92
32 contacts
1832: 4A 250V.................................................................... 96
35 contacts
2235: 5A 500V.................................................................... 100
38 contacts
2238: 5A 500V.................................................................... 104
41 contacts
2041: 3A 250V.................................................................... 108
48 contacts
2448: 5A 500V.................................................................... 112
55 contacts
2255: 3A 250V.................................................................... 116
61 contacts
2461: 3A 250V.................................................................... 120
Electrical parameters according to UL1977 * Ethernet compatible see pages 164 & 165

15
UTO Series | Connector

Upgrade of the UTO Series

Old UTO New UTO

Description of change:
To better meet the demanding requirements and diversity of industrial markets/applications, Souriau changed the position of the wavy
washer inside the plug. This slight modification makes the new version of the UTO sealed to IP68/69K in dynamic conditions.

Product part number:


Below is an overview of the old part numbers with the corresponding new part numbers.
Note that some of the old part numbers where backshells were included will now be sold individually, i.e. plug connector + backshell.

Old part number New part number connector New part number backshell Comments
UTO0/6-S/PT UT00/6-S/PH(6) - -
UTO0-S/PHT UT00-S/PH(6) - -
UTO0/6AC-S/PT UT00/6-S/PH(6) - -
UTO0/6PG-S/PHT UT00/6-S/PH(6) UT0-AC -
UTO-21/22- Keep old part number UT0-JC Silksreen version
UTO-44/45- Keep old part number - Screw coupling version
UTO-ACT - UT0-AC 851 backshell Nickel plated
Longer threading on connector side
UTO-PGT - UT0-JC
+ metric cable gland
Longer threading on connector side
UTOS-PGT - UT0S-JC
+ shielded metric cable gland
U-AD01T UT0-AD01 UT0-AD01 Longer threading to achieve sealing
Used on old UT06-45N screw
U-AD01N Keep old part number -
coupling version

16
UTO Series | Connector

Cable Assembly
SOURIAU has provided connectors for various applications for more than 90 years and has been used in the most extreme environments.
Conscious about the difficulty in finding a quick and reliable harness manufacturer, we began our own in-house cable assembly production.
It allows customers to reduce the number of suppliers and to take advantage of the “best in class” quality of the SOURIAU group.
Overmoulding is a process that further enhances the sealing properties and helps to minimize stress on the cable termination to the
connector. In addition, the wires are encapsulated inside the molding which creates a barrier preventing liquid/moisture from entering the
equipment through the connector or cable jacket if breached.

Connector
How to choose the outer jacket material
Please consult us

TPE
Cleaner,
chlorine

Static installation SILICON


Static installation

OUTDOOR FEP
Immersed

Static installation
(black outer jacket)
UV resistance
Chemical aggression

PUR PTFE
Static installation
Static or dynamic installation

INDOOR
Wet

PVC
Static installation

-40°C +80°C Ambient temperature

17
UTO Series | Connector

Overmoulding Description

O-ring
Compound Braid Cable outer
sheath

PVC or PUR
Thermoplastic insert Overmoulding overmoulding
adapter

Discrete connector

If cable jacket is breached...

GOOD

...water ingress unhampered, leading to damage.

Overmoulded connector

If cable jacket is breached...

BEST

...prevents water ingress via capillary action.

18
UTO Series | Connector

UTO Robust Metal & Shielded Cable Assembly


Description
Connector
• Shielded metal connector
• Extreme sealing: IP68/69K dynamic mated
• 26 layouts
• Rapid 1/3 turn connection

Cable
• TPE outer sheath (black)
• 300V
• Shielded
• Flammability rating UL 1581
Sec.1080 (VW-1)

Applications
• Machining Centers (Oil Resistant)
• Assembly Automation
Equipment

Connector
• Geophysical Equipment
• Solar (UV Stable)
• Outdoor Displays

Specifications

PLATING SALT SPRAY degree WATERPROOF coupling

Black anodized* 96 H IP68/69K


-40° C up to 105° C 500 matings/unmatings
Nickel 48 H dynamic mated
* Custom black anodized version available on demand

Custom Capabilities

Harness with custom cable Harness with double ends Y or T shape connection

19
UTO Series | Connector

103 (Shell size 10, 2 + ground, 3x#16)

OR OR OR OR Layout

WITH

Connector Part Numbers Drilling pattern see page 176

Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00103PH UT00103SH


receptacle IP68 & IP69K 96h UT00103PH6 UT00103SH6
IP67, IP68 & IP69K 48h UT06103PH UT06103SH
Plug
Contacts IP67, IP68 & IP69K 96h UT06103PH02(Black) UT06103SH02(Black)
supplied separately
see page 23 IP67 48h UT07103PH UT07103SH

Jam nut IP68 & IP69K 48h UT07103PH6 UT07103SH6


receptacle IP67 96h UT07103PH01 UT07103SH01
IP68 & IP69K 96h UT07103PH601 UT07103SH601

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 5/8 UT010JCSL UT010JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL

Metal cable clamp with strain relief (Fig.5) - 5 UT010AC


Metal shrink boot adaptor (Fig.6) - - UT010AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN

20
16A/150V
UTO Series | Connector
per IEC 61984

103 (Shell size 10, 2 + ground, 3x#16) 2+

Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 23.8 33 maxi 21.8
11.3
Male Male

Ø 20.0
Female Female
1.6
18.2 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 27 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 14.9

18.2

16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9 mounting
22.2 18.2
33 maxi Ø 17.3

Backshells (for Mated Connector Length: See Page 153)

31.0 24.7
Short version - 49.1 Short version - 49.1
Ø 16.3

Ø 21.0
21.6

Long version - 61.1 Long version - 61.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

48.0
Short version - 59.1 Short version - 60.1 60.6
30.0

Long version - 71.1 Long version - 71.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

21
UTO Series | Connector

103 (Shell size 10, 2 + ground, 3x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT010DCG* UTG610DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD12B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT010DC

22
16A/150V
UTO Series | Connector
per IEC 61984

103 (Shell size 10, 2 + ground, 3x#16) 2+

Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 103 Derating Curves


Current (A)

UL 30
28
10A 500V UL94 V-0 25
Test 23

conditions 20
CSA 18
Contact used: 15
7A 500V UL94 V-0 Machined contacts 13
Wires used: 10
1.31mm² 8
IEC 5

16A 150V 2.5kV 3 3


0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

23
UTO Series | Connector

142G1 (Shell size 14, 2 + ground, 3x#8)

OR OR OR OR Layout

WITH

Connector Part Numbers Drilling pattern see page 176

Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00142G1PH UT00142G1SH


receptacle IP68 & IP69K 96h UT00142G1PH6 UT00142G1SH6
IP67, IP68 & IP69K 48h UT06142G1PH UT06142G1SH
Plug
Contacts IP67, IP68 & IP69K 96h UT06142G1PH02(Black) UT06142G1SH02(Black)
supplied separately
see page 27 IP67 48h UT07142G1PH UT07142G1SH

Jam nut IP68 & IP69K 48h UT07142G1PH6 UT07142G1SH6


receptacle IP67 96h UT07142G1PH01 UT07142G1SH01
IP68 & IP69K 96h UT07142G1PH601 UT07142G1SH601

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT014JCSL UT014JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL

Metal cable clamp with strain relief (Fig.5) - 10 UT014AC


Metal shrink boot adaptor (Fig.6) - - UT014AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN

24
40A/250V
UTO Series | Connector
per IEC 61984

142G1 (Shell size 14, 2 + ground, 3x#8) 2+

Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 28.6 34 maxi 29.3
11.3
Male Male

Ø 26.8
Female Female
1.6
23.0 34
33 maxi

Jam Nut - UTO7 Panel Cut Out


33.9 maxi 35 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 22.1

23.0

24.1
Front
.5
mounting 25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25

Backshells (for Mated Connector Length: See Page 153)

34.0 24.7
Short version - 52.1 Short version - 53.1
Ø 22.5

Ø 27.0
27.4

Long version - 68.1 Long version - 69.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

52.0
Short version - 65.1 Short version - 65.1 67.7
36.5

Long version - 81.1 Long version - 81.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

25
UTO Series | Connector

142G1 (Shell size 14, 2 + ground, 3x#8)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Hand Tool

Part number Part number


UT014DCG* UTG614DCG*
Part number
M317
Gasket

Positioner + Locator Setting

Part number / Neoprene


UTFD14B

Part number
VGE10078A

Extraction Tool #8

Part number
51060210936

* For dustcap without chain, skip "G", e.g. UT014DC

26
40A/250V
UTO Series | Connector
per IEC 61984

142G1 (Shell size 14, 2 + ground, 3x#8) 2+

Contacts
Part number Max Max
#8 Contact type AWG
wire Ø insulator Ø
Male Female
16 82913601A 82913600A 1.72
14 82913603A 82913602A 2.22
Crimp

Machined 12 82913605A 82913604A 2.82 6.5


10 82913607A 82913606A 3.50
8 82913609A 82913608A 4.35
PCB

Machined (2) - 82911685NPC(1) 82911684NPC(1) - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(3): For dimensions see page 132

Electrical Characteristics UTO 142G1 Derating Curves


Current (A)
50

UL 45

40
44A 600V UL94 V-0
Test 35

conditions 30

CSA 25
Contact used:
30A 600V UL94 V-0 Machined contacts
20

15
Wires used:
6mm² 10
IEC 5

40A 250V 3kV 3 0


0 20 40 60 80 100 120
Ambient Operating Temperature (°C)

Current use Limited use Not recommended use

27
UTO Series | Connector

124 (Shell size 12, 3 + ground, 4x#16)

Layout
OR OR OR OR

WITH

Connector Part Numbers Drilling pattern see page 176

Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00124PH UT00124SH


receptacle IP68 & IP69K 96h UT00124PH6 UT00124SH6
IP67, IP68 & IP69K 48h UT06124PH UT06124SH
Plug
Contacts IP67, IP68 & IP69K 96h UT06124PH02(Black) UT06124SH02(Black)
supplied separately
see page 31 IP67 48h UT07124PH UT07124SH

Jam nut IP68 & IP69K 48h UT07124PH6 UT07124SH6


receptacle IP67 96h UT07124PH01 UT07124SH01
IP68 & IP69K 96h UT07124PH601 UT07124SH601

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT012JCS UT012JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT012JCSL UT012JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S12JCS UT0S12JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S12JCSL UT0S12JCL

Metal cable clamp with strain relief (Fig.5) - 8.2 UT012AC


Metal shrink boot adaptor (Fig.6) - - UT012AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/12 UT012LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 04/11.9 UT0S12JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 04/11.9 UT012JCPGN

28
16A/150V
UTO Series | Connector
per IEC 61984

124 (Shell size 12, 3 + ground, 4x#16)


Dimensions 3+

Square Flange - UTO0 Plug - UTO6


33.3 maxi 26.2 33 maxi 26.1
11.3
Male Male

Ø 23.6
Female Female
1.6
20.6 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 32 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 18.9

20.6

21.0
Front
mounting .2
22
Ø 18.4
Female Rear
17.9 mounting
27 20.6
33 maxi Ø 21.8

Backshells (for Mated Connector Length: See Page 153)

31.5 24.7
Short version - 49.1 Short version - 50.1
Ø 19.4

Ø 27.0
25.0

Long version - 62.1 Long version - 63.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

50.0
Short version - 62.1 Short version - 62.1 62.7
33.5

Long version - 75.1 Long version - 75.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

29
UTO Series | Connector

124 (Shell size 12, 3 + ground, 4x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT012DCG* UTG612DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD13B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT012DC

30
16A/150V
UTO Series | Connector
per IEC 61984

124 (Shell size 12, 3 + ground, 4x#16)


Contacts 3+

Part number Max Max


#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 124 Derating Curves


Current (A)
30

UL 28
25
16A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
13A 500V UL94 V-0 Machined contacts
13
10
Wires used:
8
1.31mm²
IEC 5
3
16A 150V 2.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

31
UTO Series | Connector

102W2 (Shell size 10, 2x#12 + 2x#20)

Layout
OR OR OR OR

WITH

Connector Part Numbers Drilling pattern see page 176

Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00102W2PH UT00102W2SH


receptacle IP68 & IP69K 96h UT00102W2PH6 UT00102W2SH6
IP67, IP68 & IP69K 48h UT06102W2PH UT06102W2SH
Plug
Contacts IP67, IP68 & IP69K 96h UT06102W2PH02(Black) UT06102W2SH02(Black)
supplied separately
see page 35 IP67 48h UT07102W2PH UT07102W2SH

Jam nut IP68 & IP69K 48h UT07102W2PH6 UT07102W2SH6


receptacle IP67 96h UT07102W2PH01 UT07102W2SH01
IP68 & IP69K 96h UT07102W2PH601 UT07102W2SH601

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 5/8 UT010JCSL UT010JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL

Metal cable clamp with strain relief (Fig.5) - 5 UT010AC


Metal shrink boot adaptor (Fig.6) - - UT010AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN

32
25A/200V
UTO Series | Connector
per IEC 61984

102W2 (Shell size 10, 2x#12 + 2x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
4
33.3 maxi 23.8 33 maxi 21.8
11.3
Male Male

Ø 20
Female Female
1.6
18.2 25.5 maxi
32 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 27 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 14.9

18.2

16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9
22.2 mounting
33 maxi 18.2 Ø 17.3

Backshells (for Mated Connector Length: See Page 153)

31.0 24.7
Short version - 49.1 Short version - 49.1
Ø 16.3

Ø 21.0
21.6

Long version - 61.1 Long version - 61.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

48.0
Short version - 59.1 Short version - 60.1 60.6
30.0

Long version - 71.1 Long version - 71.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

33
UTO Series | Connector

102W2 (Shell size 10, 2x#12 + 2x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Crimp Tooling #20

Part number Part number Part number Part number


UT010DCG* UTG610DCG* Shandles Toolkit

Gasket

Part number
Contacts Contact size
Part number / Neoprene of head
RM/RC 24W3K(1) S20RCM*
UTFD12B
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Crimp Tooling #12
Handle Head Complete set

Extraction Tool #20

Part number Hand Tool Part number


Positioner + Locator Setting
M317 Part number
VGE10077A
RX20D44

Extraction Tooling #12

Part number
Extraction Tool
51060210924
* For dustcap without chain, skip "G", e.g. UT010DC

34
25A/200V
UTO Series | Connector
per IEC 61984

102W2 (Shell size 10, 2x#12 + 2x#20)


Contacts
Part number Max Max
#20 Contact type AWG
Male Female wire Ø insulator Ø 4
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -

#12
22 82911457NA 82911456A 0.87
20 82911459NA 82911458A 1.12
18 82911461NA 82911460A 1.42
Crimp

Machined 4.90
16 82911463NA 82911462A 1.72
14 82911465NA 82911464A 2.22
12 82911467NA 82911466A 2.82
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 or SM24WL3S26
(3): For dimensions see page 132

Electrical Characteristics UTO 102W2 Derating Curves


Current (A)
50

UL 45

20A 500V UL94 V-0 40

Test 35

conditions 30
CSA 25
Contact used:
18A 500V UL94 V-0 Machined contacts 20

Wires used: 15
0.518mm²
IEC 3.300mm²
10

5
25A 200V 3kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

35
UTO Series | Connector

104 (Shell size 10, 4x#16)


WITH

OR single wire sealing (1)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 176

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00104PH UT00104SH


receptacle IP68 & IP69K 96h UT00104PH6 UT00104SH6
IP67, IP68 & IP69K 48h UT06104PH UT06104SH(1)
Plug
Contacts IP67, IP68 & IP69K 96h UT06104PH02 (Black) UT06104SH02(1) (Black)
supplied separately
see page 39 IP67 48h UT07104PH(1) UT07104SH

Jam nut IP68 & IP69K 48h UT07104PH6(1) UT07104SH6


receptacle IP67 96h UT07104PH01 (1)
UT07104SH01
IP68 & IP69K 96h UT07104PH601 (1)
UT07104SH601
* Other discrimination keying option, see page 180 (1): For single wire sealing solution please add GN or GJC after UT06 or UT07. Eg UT07GN104PH

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 5/8 UT010JCSL UT010JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL

Metal cable clamp with strain relief (Fig.5) - 5 UT010AC


Metal shrink boot adaptor (Fig.6) - - UT010AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN

36
13A/150V
UTO Series | Connector
per IEC 61984

104 (Shell size 10, 4x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
4
33.3 maxi 23.8 33 maxi 21.8
11.3
Male Male

Ø 20
Female Female
1.6
18.2 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 27 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 14.9

18.2

16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9
22.2 mounting
33 maxi 18.2 Ø 17.3

Backshells (for Mated Connector Length: See Page 153)


13.0 49.9

Short version - 49.1 Short version - 49.1


Ø 22.0

Ø 22.0

GN plastic GJC plastic


31.0 24.7
Long version - 61.1 Long version - 61.1
Fig. 1 Fig. 2
Ø 16.3

Ø 21.0
21.6

Short version - 59.1 Short version - 60.1


Fig. 5 Fig. 6
48.0
60.6
30.0

Long version - 71.1 Long version - 71.1

Fig. 3 Fig. 4
Fig. 7 Fig. 8

Note: all dimensions are in mm

37
UTO Series | Connector

104 (Shell size 10, 4x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT010DCG* UTG610DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD12B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT010DC

38
13A/150V
UTO Series | Connector
per IEC 61984

104 (Shell size 10, 4x#16)


Contacts
Part number Max Max
#16 Contact type AWG
Male Female wire Ø insulator Ø 4
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K(1) RC24M9K(1) 0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 104 Derating Curves


Current (A)

UL 30
28
10A 500V UL94 V-0 25
Test 23

conditions 20
CSA 18
Contact used: 15
7A 500V UL94 V-0 Machined contacts 13
Wires used: 10
1.31mm² 8
IEC 5

13A 150V 2.5kV 3 3


0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

39
UTO Series | Connector

103W3 (Shell size 10, 3x#16 + 3x#20)

Layout
OR OR OR OR

WITH

Connector Part Numbers Drilling pattern see page 176

Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00103W3PH UT00103W3SH


receptacle IP68 & IP69K 96h UT00103W3PH6 UT00103W3SH6
IP67, IP68 & IP69K 48h UT06103W3PH UT06103W3SH
Plug
Contacts IP67, IP68 & IP69K 96h UT06103W3PH02(Black) UT06103W3SH02(Black)
supplied separately
see page 43 IP67 48h UT07103W3PH UT07103W3SH

Jam nut IP68 & IP69K 48h UT07103W3PH6 UT07103W3SH6


receptacle IP67 96h UT07103W3PH01 UT07103W3SH01
IP68 & IP69K 96h UT07103W3PH601 UT07103W3SH601

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 5/8 UT010JCSL UT010JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL

Metal cable clamp with strain relief (Fig.5) - 5 UT010AC


Metal shrink boot adaptor (Fig.6) - - UT010AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN

40
5A/40V
UTO Series | Connector
per IEC 61984

103W3 (Shell size 10, 3x#16 + 3x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
36 maxi 23.8 35 maxi 21.8
11.3
Male Male
6

Ø 20
Female Female
1.6
18.2 27 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 27 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 14.9

18.2

16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9
22.2 mounting
33 maxi 18.2 Ø 17.3

Backshells (for Mated Connector Length: See Page 153)

31.0 24.7
Short version - 49.1 Short version - 49.1
Ø 16.3

Ø 21.0
21.6

Long version - 61.1 Long version - 61.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

48.0
Short version - 59.1 Short version - 60.1 60.6
30.0

Long version - 71.1 Long version - 71.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

41
UTO Series | Connector

103W3 (Shell size 10, 3x#16 + 3x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT010DCG* UTG610DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)


Part number
Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
Part number / Neoprene Part number / Polyamide 6.6
RM/RC 16M23K(1) Standard contacts S16RCM16*
UTFD12B SMSPKE0 RM/RC 14M30K(1) S16RCM14*
#16
See page 180 for more information SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Extraction Tool #16 Extraction Tool #20 SM/SC 16ML1TK6(1) S16SCML1*
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
Part number Part number york090 173 to 174
RX2025GE1 RX20D44 RM/RC DX60xxD28

RM/RC 24W3K(1) S20RCM


RM/RC 20W3K(1) Standard contacts S20RCM
RM/RC 18W3K(1) #20
S20RCM
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20
SM/SC 20WL3(1)(2) S20SCM20
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT010DC

42
5A/40V
UTO Series | Connector
per IEC 61984

103W3 (Shell size 10, 3x#16 + 3x#20)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K(1) RC24M9K(1) 0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
6
Machined
22-20 RM20M12K(1) RC20M12K(1) 1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K(1) RC14M30K(1) 2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6(1)(2) SC16M1TK6(1)(2) - 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6(1)(2) SC14M1TK6(1)(2) - 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -

#20
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60


Stamped & Formed reeled contacts 26-24 SM24W3S26(1)(2) SC24W3S25(1)(2) - 0.90-1.60
See note (2) for loose piece 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26(1)(2) SC20W3S25(1)(2) - 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -


(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 or SM24WL3S26
(3): For dimensions see page 132

Electrical Characteristics UTO 103W3 Derating Curves


Current (A)

30
UL 28

5A 250V UL94 V-0 Test


25
23
conditions 20

CSA Contact used:


18
15
5A 200V UL94 V-0 Machined contacts 13
Wires used: 10
1.310mm² 8
0.518mm²
IEC 5
3
5A 40V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

43
UTO Series | Connector

106 (Shell size 10, 6x#20)

Layout
OR OR OR OR

WITH

Connector Part Numbers Drilling pattern see page 176

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT0W0106PH UT0W0106SH


receptacle IP68 & IP69K 96h UT0W0106PH6 UT0W0106SH6
IP67, IP68 & IP69K 48h UT0W6106PH UT0W6106SH
Plug
Contacts IP67, IP68 & IP69K 96h UT0W6106PH02(Black) UT0W6106SH02(Black)
supplied separately
see page 47 IP67 48h UT0W7106PH UT0W7106SH

Jam nut IP68 & IP69K 48h UT0W7106PH6 UT0W7106SH6


receptacle IP67 96h UT0W7106PH01 UT0W7106SH01
IP68 & IP69K 96h UT0W7106PH601 UT0W7106SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 5/8 UT010JCSL UT010JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL

Metal cable clamp with strain relief (Fig.5) - 5 UT010AC


Metal shrink boot adaptor (Fig.6) - - UT010AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN

44
7A/80V
UTO Series | Connector
per IEC 61984

106 (Shell size 10, 6x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 23.8 33 maxi 21.8
11.3
Male Male
6

Ø 20
Female Female
1.6
18.2 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 27 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 14.9

18.2

16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9
22.2 mounting
33 maxi 18.2 Ø 17.3

Backshells (for Mated Connector Length: See Page 153)

31.0 24.7
Short version - 49.1 Short version - 49.1
Ø 16.3

Ø 21.0
21.6

Long version - 61.1 Long version - 61.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

48.0
Short version - 59.1 Short version - 60.1 60.6
30.0

Long version - 71.1 Long version - 71.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

45
UTO Series | Connector

106 (Shell size 10, 6x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT010DCG* UTG610DCG* Shandles Toolkit

Gasket Crimp Tooling (without Shandles)

Part number / Neoprene


UTFD12B

Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set

Extraction Tool #20

Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT024DC

46
7A/80V
UTO Series | Connector
per IEC 61984

106 (Shell size 10, 6x#20)


Contacts
Part number Max Max
#20 Contact type AWG
wire Ø insulator Ø
Male Female
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60 6
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 106 Derating Curves


Current (A)

UL 14

5A 250V UL94 V-0 12

Test 10
conditions
CSA 8
Contact used:
4A 250V UL94 V-0 Machined contacts 6

Wires used:
4
0.518mm²
IEC 2
7A 80V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

47
UTO Series | Connector

147 (Shell size 14, 6 + ground, 7x#16)


WITH

OR single wire sealing (1)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 176

Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00147PH UT00147SH


receptacle IP68 & IP69K 96h UT00147PH6 UT00147SH6
IP67, IP68 & IP69K 48h UT06147PH UT06147SH(1)
Plug
Contacts IP67, IP68 & IP69K 96h UT06147PH02 (Black) UT06147SH02(1) (Black)
supplied separately
see page 51 IP67 48h UT07147PH(1) UT07147SH

Jam nut IP68 & IP69K 48h UT07147PH6(1) UT07147SH6


receptacle IP67 96h UT07147PH01 (1)
UT07147SH01
IP68 & IP69K 96h UT07147PH601 (1)
UT07147SH601
(1): For single wire sealing solution please add GN or GJC after UT06 or UT07. Eg UT07GN147PH

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT014JCSL UT014JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL

Metal cable clamp with strain relief (Fig.5) - 10 UT014AC


Metal shrink boot adaptor (Fig.6) - - UT014AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN

48
16A/150V
UTO Series | Connector
per IEC 61984

147 (Shell size 14, 6 + ground, 7x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 28.6 33 maxi 29.3
11.3
Male Male

Ø 26.8
Female Female
1.6
23.0 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 35 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 22.1

23.0

24.1
Front
mounting .5
25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25

Backshells (for Mated Connector Length: See Page 153)


9.5 52.0

Short version - 52.1 Short version - 53.1


Ø 29.8

Ø 29.8

GN plastic GJC plastic


34.0 24.7
Long version - 68.1 Long version - 69.1
Fig. 1 Fig. 2
Ø 22.5

Ø 27.0
27.4

Short version - 65.1 Short version - 65.1


Fig. 5 Fig. 6
52.0
67.7
36.5

Long version - 81.1 Long version - 81.1

Fig. 3 Fig. 4
Fig. 7 Fig. 8

Note: all dimensions are in mm

49
UTO Series | Connector

147 (Shell size 14, 6 + ground, 7x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT014DCG* UTG614DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD14B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT014DC

50
16A/150V
UTO Series | Connector
per IEC 61984

147 (Shell size 14, 6 + ground, 7x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20 6
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 147 Derating Curves


Current (A)
30

UL 28
25
10A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
8
1.31mm²
IEC 5

16A 150V 2.5kV 3 3


0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

51
UTO Series | Connector

128 (Shell size 12, 8x#16)


WITH

OR
single wire sealing (1)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 176

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00128PH UT00128SH


receptacle IP68 & IP69K 96h UT00128PH6 UT00128SH6
IP67, IP68 & IP69K 48h UT06128PH UT06128SH(1)
Plug
Contacts IP67, IP68 & IP69K 96h UT06128PH02 (Black) UT06128SH02(1) (Black)
supplied separately
see page 55 IP67 48h UT07128PH(1) UT07128SH

Jam nut IP68 & IP69K 48h UT07128PH6(1) UT07128SH6


receptacle IP67 96h UT07128PH01 (1)
UT07128SH01
IP68 & IP69K 96h UT07128PH601 (1)
UT07128SH601
* Other discrimination keying option, see page 180 (1): For single wire sealing solution please add GN or GJC after UT06 or UT07. Eg UT07GN128PH

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT012JCS UT012JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT012JCSL UT012JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S12JCS UT0S12JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S12JCSL UT0S12JCL

Metal cable clamp with strain relief (Fig.5) - 8.2 UT012AC


Metal shrink boot adaptor (Fig.6) - - UT012AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/12 UT012LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 04/11.9 UT0S12JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 04/11.9 UT012JCPGN

52
10A/125V
UTO Series | Connector
per IEC 61984

128 (Shell size 12, 8x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 26.2 33 maxi 26.1
11.3
Male Male

Ø 23.6
Female Female 8
1.6
20.6 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 32 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 18.9

20.6

21.0
Front
mounting .2
22
Ø 18.4
Female Rear
17.9 mounting
27 20.6
33 maxi Ø 21.8

Backshells (for Mated Connector Length: See Page 153)


10.7 49.9

Short version - 49.1 Short version - 50.1


Ø 25.4

Ø 25.4

GN plastic GJC plastic


31.5 24.7
Long version - 62.1 Long version - 63.1
Fig. 1 Fig. 2
Ø 19.4

Ø 27.0
25.0

Short version - 62.1 Short version - 62.1


Fig. 5 Fig. 6
50.0
62.7
33.5

Long version - 75.1 Long version - 75.1

Fig. 3 Fig. 4
Fig. 7 Fig. 8

Note: all dimensions are in mm

53
UTO Series | Connector

128 (Shell size 12, 8x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT012DCG* UTG612DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD13B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT012DC

54
10A/125V
UTO Series | Connector
per IEC 61984

128 (Shell size 12, 8x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20
8
26-24 SM24M1TK6 (1)(2)
SC24M1TK6 (1)(2)
- 0.90-1.60
22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 128 Derating Curves


Current (A)
30

UL 28
25
10A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

10A 125V 2.5kV 3 3


0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

55
UTO Series | Connector

148 (Shell size 14, 4x#12 + 4x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 176

Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT00148PH UT00148SH


receptacle IP68 & IP69K 96h UT00148PH6 UT00148SH6
IP67, IP68 & IP69K 48h UT06148PH UT06148SH
Plug
Contacts IP67, IP68 & IP69K 96h UT06148PH02(Black) UT06148SH02(Black)
supplied separately
see page 59 IP67 48h UT07148PH UT07148SH

Jam nut IP68 & IP69K 48h UT07148PH6 UT071482SH6


receptacle IP67 96h UT071482PH01 UT07148SH01
IP68 & IP69K 96h UT07148PH601 UT07148SH601

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT014JCSL UT014JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL

Metal cable clamp with strain relief (Fig.5) - 10 UT014AC


Metal shrink boot adaptor (Fig.6) - - UT014AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN

56
17A/230V
UTO Series | Connector
per IEC 61984

148 (Shell size 14, 4x#12 + 4x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 28.6 35 maxi 29.3
11.3
Male Male

Ø 26.8
Female Female 8
1.6
23.0 33 maxi
32 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 35 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 22.1

23.0

24.1
Front
.5
mounting 25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25

Backshells (for Mated Connector Length: See Page 153)

34.0 24.7
Short version - 52.1 Short version - 53.1
Ø 22.5

Ø 27.0
27.4

Long version - 68.1 Long version - 69.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

52.0
Short version - 65.1 Short version - 65.1 67.7
36.5

Long version - 81.1 Long version - 81.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

57
UTO Series | Connector

148 (Shell size 14, 4x#12 + 4x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT014DCG* UTG614DCG* Shandles
Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD14B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
Part number RM/RC 14M30K(1) S16RCM14*
#16
RX2025GE1 SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
SM/SC 16ML1TK6(1) S16SCML1*
Crimp Tooling #12 SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
Part number Hand Tool Part number york090 173 to 174
M317
Positioner + Locator Setting RM/RC DX60xxD28
VGE10078A (1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

Part number
Extraction Tool
51060210924
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT014DC

58
17A/230V
UTO Series | Connector
per IEC 61984

148 (Shell size 14, 4x#12 + 4x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20
8
26-24 SM24M1TK6 (1)(2)
SC24M1TK6 (1)(2)
- 0.90-1.60
22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -

#12
22 82911457NA 82911456A 0.87
20 82911459NA 82911458A 1.12
18 82911461NA 82911460A 1.42
Crimp

Machined 4.90
16 82911463NA 82911462A 1.72
14 82911465NA 82911464A 2.22
12 82911467NA 82911466A 2.82
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 148 Derating Curves


Current (A)
45

UL 40

25A 250V UL94 V-0 35


Test 30
conditions
CSA 25

Contact used:
17A 250V UL94 V-0 Machined contacts
20

15
Wires used:
1.31mm² 10
IEC 3.30mm²
5
17A 230V 1.5kV 3 0
0 25 45 65 85 105 125
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

59
UTO Series | Connector

1210 (Shell size 12, 10x#20)

Layout
OR OR OR OR

WITH

Connector Part Numbers Drilling pattern see page 176

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT0W01210PH UT0W01210SH


receptacle IP68 & IP69K 96h UT0W01210PH6 UT0W01210SH6
IP67, IP68 & IP69K 48h UT0W61210PH UT0W61210SH
Plug
Contacts IP67, IP68 & IP69K 96h UT0W61210PH02(Black) UT0W61210SH02(Black)
supplied separately
see page 63 IP67 48h UT0W71210PH UT0W71210SH

Jam nut IP68 & IP69K 48h UT0W71210PH6 UT0W71210SH6


receptacle IP67 96h UT0W71210PH01 UT0W71210SH01
IP68 & IP69K 96h UT0W71210PH601 UT0W71210SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT012JCS UT012JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT012JCSL UT012JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S12JCS UT0S12JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S12JCSL UT0S12JCL

Metal cable clamp with strain relief (Fig.5) - 8.2 UT012AC


Metal shrink boot adaptor (Fig.6) - - UT012AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/12 UT012LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 04/11.9 UT0S12JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 04/11.9 UT012JCPGN

60
6A/40V
UTO Series | Connector
per IEC 61984

1210 (Shell size 12, 10x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 26.2 33 maxi 26.1
11.3
Male Male

Ø 23.6
Female Female
1.6
20.6 25.5 maxi
25.2 maxi
10

Jam Nut - UTO7 Panel Cut Out


34 maxi 32 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 18.9

20.6

21.0
Front
mounting .2
22
Ø 18.4
Female Rear
17.9 mounting
27 20.6
33 maxi Ø 21.8

Backshells (for Mated Connector Length: See Page 153)

31.5 24.7
Short version - 49.1 Short version - 50.1
Ø 19.4

Ø 27.0
25.0

Long version - 62.1 Long version - 63.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

50.0
Short version - 62.1 Short version - 62.1 62.7
33.5

Long version - 75.1 Long version - 75.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

61
UTO Series | Connector

1210 (Shell size 12, 10x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT012DCG* UTG612DCG* Shandles Toolkit

Gasket Crimp Tooling (without Shandles)

Part number / Neoprene


UTFD13B

Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set

Extraction Tool #20

Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT012DC

62
6A/40V
UTO Series | Connector
per IEC 61984

1210 (Shell size 12, 10x#20)


Contacts
Part number Max Max
#20 Contact type AWG
wire Ø insulator Ø
Male Female
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10

10
PCB

Machined (3) - RMW5016K RCW5016K - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132

Electrical Characteristics UT0 1210 Derating Curves


Current (A)

UL 12

5A 250V UL94 V-0 10


Test
conditions 8

CSA
Contact used: 6
4A 250V UL94 V-0 Machined contacts
Wires used: 4
0.518mm²
IEC 2

6A 40V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

63
UTO Series | Connector

1412 (Shell size 14, 12x#16)


WITH

OR single wire sealing (1)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 176

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT001412PH UT001412SH


receptacle IP68 & IP69K 96h UT001412PH6 UT001412SH6
IP67, IP68 & IP69K 48h UT061412PH UT061412SH(1)
Plug
Contacts IP67, IP68 & IP69K 96h UT061412PH02 (Black) UT061412SH02(1) (Black)
supplied separately
see page 67 IP67 48h UT071412PH(1) UT071412SH

Jam nut IP68 & IP69K 48h UT071412PH6(1) UT071412SH6


receptacle IP67 96h UT071412PH01 (1)
UT071412SH01
IP68 & IP69K 96h UT071412PH601 (1)
UT071412SH601
* Other discrimination keying option, see page 180 (1): For single wire sealing solution please add GN or GJC after UT06 or UT07. Eg UT07GN1412PH

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT014JCSL UT014JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL

Metal cable clamp with strain relief (Fig.5) - 10 UT014AC


Metal shrink boot adaptor (Fig.6) - - UT014AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN

64
10A/150V
UTO Series | Connector
per IEC 61984

1412 (Shell size 14, 12x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 28.6 33 maxi 29.3
11.3
Male Male

Ø 26.8
Female Female
1.6
23.0 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out 12


34 maxi 35 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 22.1

23.0

24.1
Front
mounting .5
25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25

Backshells (for Mated Connector Length: See Page 153)


9.5 52.0

Short version - 52.1 Short version - 53.1


Ø 29.8

Ø 29.8

GN plastic GJC plastic


34.0 24.7
Long version - 68.1 Long version - 69.1
Fig. 1 Fig. 2
Ø 22.5

Ø 27.0
27.4

Short version - 65.1 Short version - 65.1


Fig. 5 Fig. 6
52.0
67.7
36.5

Long version - 81.1 Long version - 81.1

Fig. 3 Fig. 4
Fig. 7 Fig. 8

Note: all dimensions are in mm

65
UTO Series | Connector

1412 (Shell size 14, 12x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT014DCG* UTG614DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD14B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT014DC

66
10A/150V
UTO Series | Connector
per IEC 61984

1412 (Shell size 14, 12x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00 12
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 1412 Derating Curves


Current (A)
30

UL 28
25
10A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

10A 150V 2.5kV 3 3


0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

67
UTO Series | Connector

1492 (Shell size 14, 12x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 176

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT001492PH UT001492SH


receptacle IP68 & IP69K 96h UT001492PH6 UT001492SH6
IP67, IP68 & IP69K 48h UT061492PH UT061492SH
Plug
Contacts IP67, IP68 & IP69K 96h UT061492PH02(Black) UT061492SH02(Black)
supplied separately
see page 71 IP67 48h UT071492PH UT071492SH

Jam nut IP68 & IP69K 48h UT071492PH6 UT071492SH6


receptacle IP67 96h UT071492PH01 UT071492SH01
IP68 & IP69K 96h UT071492PH601 UT071492SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT014JCSL UT014JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL

Metal cable clamp with strain relief (Fig.5) - 10 UT014AC


Metal shrink boot adaptor (Fig.6) - - UT014AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN

68
10A/150V
UTO Series | Connector
per IEC 61984

1492 (Shell size 14, 12x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 28.6 33 maxi 29.3
11.3
Male Male

Ø 26.8
Female Female
1.6
23.0 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out 12


34 maxi 35 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 22.1

23.0

24.1
Front
.5
mounting 25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25

Backshells (for Mated Connector Length: See Page 153)

34.0 24.7
Short version - 52.1 Short version - 53.1
Ø 22.5

Ø 27.0
27.4

Long version - 68.1 Long version - 69.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

52.0
Short version - 65.1 Short version - 65.1 67.7
36.5

Long version - 81.1 Long version - 81.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

69
UTO Series | Connector

1492 (Shell size 14, 12x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT014DCG* UTG614DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD14B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT014DC

70
10A/150V
UTO Series | Connector
per IEC 61984

1492 (Shell size 14, 12x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00 12
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 1492 Derating Curves


Current (A)
30

UL 28
25
10A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

10A 150V 2.5kV 3 3


0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

71
UTO Series | Connector

1419 (Shell size 14, 19x#20)

Layout
OR OR OR OR

WITH

Connector Part Numbers Drilling pattern see page 176

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT0W01419PH UT0W01419SH


receptacle IP68 & IP69K 96h UT0W01419PH6 UT0W01419SH6
IP67, IP68 & IP69K 48h UT0W61419PH UT0W61419SH
Plug
Contacts IP67, IP68 & IP69K 96h UT0W61419PH02(Black) UT0W61419SH02(Black)
supplied separately
see page 75 IP67 48h UT0W71419PH UT0W71419SH

Jam nut IP68 & IP69K 48h UT0W71419PH6 UT0W71419SH6


receptacle IP67 96h UT0W71419PH01 UT0W71419SH01
IP68 & IP69K 96h UT0W71419PH601 UT0W71419SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 08/12 UT014JCSL UT014JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL

Metal cable clamp with strain relief (Fig.5) - 10 UT014AC


Metal shrink boot adaptor (Fig.6) - - UT014AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN

72
5A/40V
UTO Series | Connector
per IEC 61984

1419 (Shell size 14, 19x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 28.6 33 maxi 29.3
11.3
Male Male

Ø 26.8
Female Female
1.6
23.0 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 35 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2 19
Male
Ø 22.1

23.0

24.1
Front
.5
mounting 25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25

Backshells (for Mated Connector Length: See Page 153)

34.0 24.7
Short version - 52.1 Short version - 53.1
Ø 22.5

Ø 27.0
27.4

Long version - 68.1 Long version - 69.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

52.0
Short version - 65.1 Short version - 65.1 67.7
36.5

Long version - 81.1 Long version - 81.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

73
UTO Series | Connector

1419 (Shell size 14, 19x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT014DCG* UTG614DCG* Shandles Toolkit

Gasket Crimp Tooling (without Shandles)

Part number / Neoprene


UTFD14B

Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set

Extraction Tool #20

Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT014DC

74
5A/40V
UTO Series | Connector
per IEC 61984

1419 (Shell size 14, 19x#20)


Contacts
Part number Max Max
#20 Contact type AWG
wire Ø insulator Ø
Male Female
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132

19

Electrical Characteristics UTO 1419 Derating Curves


Current (A)

UL 12

5A 250V UL94 V-0 10


Test
conditions 8
CSA
Contact used: 6
4A 250V UL94 V-0 Machined contacts
Wires used: 4
0.518mm²
IEC 2

5A 40V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

75
UTO Series | Connector

1619 (Shell size 16, 19x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 177

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT001619PH UT001619SH


receptacle IP68 & IP69K 96h UT001619PH6 UT001619SH6
IP67, IP68 & IP69K 48h UT061619PH UT061619SH
Plug
Contacts IP67, IP68 & IP69K 96h UT061619PH02(Black) UT061619SH02(Black)
supplied separately
see page 79 IP67 48h UT071619PH UT071619SH

Jam nut IP68 & IP69K 48h UT071619PH6 UT071619SH6


receptacle IP67 96h UT071619PH01 UT071619SH01
IP68 & IP69K 96h UT071619PH601 UT071619SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 9.5/14 UT016JCS UT016JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 11.5/18 UT016JCSL UT016JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 10/14.5 UT0S16JCS UT0S16JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 13.5/18 UT0S16JCSL UT0S16JCL

Metal cable clamp with strain relief (Fig.5) - 13 UT016AC


Metal shrink boot adaptor (Fig.6) - - UT016AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/16 UT016LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/16 UT0S16JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/16 UT016JCPGN

76
9A/150V
UTO Series | Connector
per IEC 61984

1619 (Shell size 16, 19x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 31.0 33 maxi 32.45
11.3
Male Male

Ø 30.0
Female Female
1.6
24.6 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 38.1 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2 19
Male
Ø 25.3

24.6

27.2
Front
mounting .3
28
Ø 24.6
Female Rear
17.9
33.3 mounting
33 maxi 24.6 Ø 28.1

Backshells (for Mated Connector Length: See Page 153)

34.0 27
Short version - 63.1 Short version - 69.1
Ø 25.8

Ø 30.0
29.4

Long version - 74.1 Long version - 80.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

55.0
Short version - 73.1 Short version - 83.1 73.1
39.5

Long version - 84.1 Long version - 94.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

77
UTO Series | Connector

1619 (Shell size 16, 19x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT016DCG* UTG616DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD15B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT016DC

78
9A/150V
UTO Series | Connector
per IEC 61984

1619 (Shell size 16, 19x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20

19
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 1619 Derating Curves


Current (A)

UL 28

9A 500V UL94 V-0 25


Test
conditions 20
CSA
Contact used:
6A 500V UL94 V-0 Machined contacts
15

Wires used:
1.31mm² 10
IEC 5

9A 150V 2.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

79
UTO Series | Connector

1823 (Shell size 18, 23x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 177

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT001823PH UT001823SH


receptacle IP68 & IP69K 96h UT001823PH6 UT001823SH6
IP67, IP68 & IP69K 48h UT061823PH UT061823SH
Plug
Contacts IP67, IP68 & IP69K 96h UT061823PH02(Black) UT061823SH02(Black)
supplied separately
see page 83 IP67 48h UT071823PH UT071823SH

Jam nut IP68 & IP69K 48h UT071823PH6 UT071823SH6


receptacle IP67 96h UT071823PH01 UT071823SH01
IP68 & IP69K 96h UT071823PH601 UT071823SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 9.5/14 UT018JCS UT018JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 11.5/18 UT018JCSL UT018JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 10/14.5 UT0S18JCS UT0S18JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 13.5/18 UT0S18JCSL UT0S18JCL

Metal cable clamp with strain relief (Fig.5) - 16.0 UT018AC


Metal shrink boot adaptor (Fig.6) - - UT018AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT018LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/16 UT0S18JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/16 UT018JCPGN

80
8A/150V
UTO Series | Connector
per IEC 61984

1823 (Shell size 18, 23x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 33.3 33 maxi 35.2
11.3
Male Male

Ø 33.3
Female Female
1.6
26.9 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 41.3 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male

23
Ø 28.4

26.9

30.3
Front
mounting .8
31
Ø 27.8
Female Rear
17.9
36.5 mounting
33 maxi 26.9 Ø 31.3

Backshells (for Mated Connector Length: See Page 153)

31.4 27
Short version - 66.1 Short version - 72.1
Ø 33.3

Ø 33.3
35.2

Long version - 76.6 Long version - 82.6


Fig. 1 Fig. 2 Fig. 5 Fig. 6

60.0
Short version - 76.1 Short version - 86.1 77.2
46.0

Long version - 86.6 Long version - 96.6

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

81
UTO Series | Connector

1823 (Shell size 18, 23x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT018DCG* UTG618DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD16B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT018DC

82
8A/150V
UTO Series | Connector
per IEC 61984

1823 (Shell size 18, 23x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - - 23


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 1823 Derating Curves


Current (A)
30

UL 28
25
8A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

8A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

83
UTO Series | Connector

1626 (Shell size 16, 26x#20)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 177

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT0W01626PH UT0W01626SH


receptacle IP68 & IP69K 96h UT0W01626PH6 UT0W01626SH6
IP67, IP68 & IP69K 48h UT0W61626PH UT0W61626SH
Plug
Contacts IP67, IP68 & IP69K 96h UT0W61626PH02(Black) UT0W61626SH02(Black)
supplied separately
see page 87 IP67 48h UT0W71626PH UT0W71626SH

Jam nut IP68 & IP69K 48h UT0W71626PH6 UT0W71626SH6


receptacle IP67 96h UT0W71626PH01 UT0W71626SH01
IP68 & IP69K 96h UT0W71626PH601 UT0W71626SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 9.5/14 UT016JCS UT016JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 11.5/18 UT016JCSL UT016JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 10/14.5 UT0S16JCS UT0S16JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 13.5/18 UT0S16JCSL UT0S16JCL

Metal cable clamp with strain relief (Fig.5) - 13 UT016AC


Metal shrink boot adaptor (Fig.6) - - UT016AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/16 UT016LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/16 UT0S16JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/16 UT016JCPGN

84
4A/40V
UTO Series | Connector
per IEC 61984

1626 (Shell size 16, 26x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 31.0 33 maxi 32.4
11.3
Male Male

Ø 30.0
Female Female
1.6
24.6 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 38.1 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 25.3

24.6

27.2
Front
mounting .3 26
28
Ø 24.6
Female Rear
17.9
33.3 mounting
33 maxi 24.6 Ø 28.1

Backshells (for Mated Connector Length: See Page 153)

34.0 27
Short version - 63.1 Short version - 69.1
Ø 25.8

Ø 30.0
29.4

Long version - 74.1 Long version - 80.1


Fig. 1 Fig. 2 Fig. 5 Fig. 6

55.0
Short version - 73.1 Short version - 83.1 73.1
39.5

Long version - 84.1 Long version - 94.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

85
UTO Series | Connector

1626 (Shell size 16, 26x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT016DCG* UTG616DCG* Shandles Toolkit

Gasket Crimp Tooling (without Shandles)

Part number / Neoprene


UTFD15B

Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set

Extraction Tool #20

Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT016DC

86
4A/40V
UTO Series | Connector
per IEC 61984

1626 (Shell size 16, 26x#20)


Contacts
Part number Max Max
#20 Contact type AWG
wire Ø insulator Ø
Male Female
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132

26

Electrical Characteristics UTO 1626 Derating Curves


Current (A)
10

UL 9

4A 250V UL94 V-0 8

Test 7

conditions 6
CSA 5
Contact used:
3A 250V UL94 V-0 Machined contacts 4
Wires used: 3
0.518mm²
IEC 2
1
4A 40V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

87
UTO Series | Connector

2028 (Shell size 20, 28x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 178

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT002028PH UT002028SH


receptacle IP68 & IP69K 96h UT002028PH6 UT002028SH6
IP67, IP68 & IP69K 48h UT062028PH UT062028SH
Plug
Contacts IP67, IP68 & IP69K 96h UT062028PH02(Black) UT062028SH02(Black)
supplied separately
see page 91 IP67 48h UT072028PH UT072028SH

Jam nut IP68 & IP69K 48h UT072028PH6 UT072028SH6


receptacle IP67 96h UT072028PH01 UT072028SH01
IP68 & IP69K 96h UT072028PH601 UT072028SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT020JCS UT020JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 15/24 UT020JCSL UT020JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S20JCS UT0S20JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S20JCSL UT0S20JCL

Metal cable clamp with strain relief (Fig.5) - 16.0 UT020AC


Metal shrink boot adaptor (Fig.6) - - UT020AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT020LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S20JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT020JCPGN

88
7A/150V
UTO Series | Connector
per IEC 61984

2028 (Shell size 20, 28x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
34.75 maxi 36.5 33 maxi 38.8
14.5
Male Male

Ø 36.5
Female Female
2.4
29.3 27.5 maxi
29 maxi

Jam Nut - UTO7 Panel Cut Out


39 maxi 46.0 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 31.6

29.3

33.5
Front
mounting .8
34
Ø 30.9
Female Rear
22.7
39.7 mounting 28
39 maxi 29.3 Ø 34.5

Backshells (for Mated Connector Length: See Page 153)

32.0 27
Short version - 74.8 Short version - 81.8
Ø 32.5

Ø 36.5
35.2

Long version - 84.6 Long version - 91.6


Fig. 1 Fig. 2 Fig. 5 Fig. 6

58.0
Short version - 88.3 Short version - 97.3 84.6
47.0

Long version - 98.1 Long version - 107.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

89
UTO Series | Connector

2028 (Shell size 20, 28x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT020DCG* UTG620DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD17B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT028DC

90
7A/150V
UTO Series | Connector
per IEC 61984

2028 (Shell size 20, 28x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
28
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 2028 Derating Curves


Current (A)
30

UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

7A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

91
UTO Series | Connector

2030 (Shell size 20, 30x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 178

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT002030PH UT002030SH


receptacle IP68 & IP69K 96h UT002030PH6 UT002030SH6
IP67, IP68 & IP69K 48h UT062030PH UT062030SH
Plug
Contacts IP67, IP68 & IP69K 96h UT062030PH02(Black) UT062030SH02(Black)
supplied separately
see page 95 IP67 48h UT072030PH UT072030SH

Jam nut IP68 & IP69K 48h UT072030PH6 UT072030SH6


receptacle IP67 96h UT072030PH01 UT072030SH01
IP68 & IP69K 96h UT072030PH601 UT072030SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT020JCS UT020JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 15/24 UT020JCSL UT020JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S20JCS UT0S20JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S20JCSL UT0S20JCL

Metal cable clamp with strain relief (Fig.5) - 16.0 UT020AC


Metal shrink boot adaptor (Fig.6) - - UT020AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT020LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S20JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT020JCPGN

92
7A/150V
UTO Series | Connector
per IEC 61984

2030 (Shell size 20, 30x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
34.75 maxi 36.5 33 maxi 38.8
14.5
Male Male

Ø 36.5
Female Female
2.4
29.3 27.5 maxi
29 maxi

Jam Nut - UTO7 Panel Cut Out


39 maxi 46.0 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 31.6

29.3

33.5
Front
mounting .8
34
Ø 30.9
Female Rear
22.7
39.7 mounting
39 maxi 29.3 Ø 34.5

30
Backshells (for Mated Connector Length: See Page 153)

32.0 27
Short version - 74.8 Short version - 81.8
Ø 32.5

Ø 36.5
35.2

Long version - 84.6 Long version - 91.6


Fig. 1 Fig. 2 Fig. 5 Fig. 6

58.0
Short version - 88.3 Short version - 97.3 84.6
47.0

Long version - 98.1 Long version - 107.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

93
UTO Series | Connector

2030 (Shell size 20, 30x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT020DCG* UTG620DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD17B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT028DC

94
7A/150V
UTO Series | Connector
per IEC 61984

2030 (Shell size 20, 30x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132
30

Electrical Characteristics UTO 2030 Derating Curves


Current (A)
30

UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

7A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

95
UTO Series | Connector

1832 (Shell size 18, 32x#20)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 177

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT0W01832PH UT0W01832SH


receptacle IP68 & IP69K 96h UT0W01832PH6 UT0W01832SH6
IP67, IP68 & IP69K 48h UT0W61832PH UT0W61832SH
Plug
Contacts IP67, IP68 & IP69K 96h UT0W61832PH02(Black) UT0W61832SH02(Black)
supplied separately
see page 99 IP67 48h UT0W71832PH UT0W71832SH

Jam nut IP68 & IP69K 48h UT0W71832PH6 UT0W71832SH6


receptacle IP67 96h UT0W71832PH01 UT0W71832SH01
IP68 & IP69K 96h UT0W71832PH601 UT0W71832SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 9.5/14 UT018JCS UT018JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 11.5/18 UT018JCSL UT018JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 10/14.5 UT0S18JCS UT0S18JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 13.5/18 UT0S18JCSL UT0S18JCL

Metal cable clamp with strain relief (Fig.5) - 16.0 UT018AC


Metal shrink boot adaptor (Fig.6) - - UT018AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT018LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/16 UT0S18JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 6.5/16 UT018JCPGN

96
4A/50V
UTO Series | Connector
per IEC 61984

1832 (Shell size 18, 32x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 33.3 33 maxi 35.2
11.3
Male Male

Ø 33.3
Female Female
1.6
26.9 25.5 maxi
25.2 maxi

Jam Nut - UTO7 Panel Cut Out


34 maxi 41.3 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 28.4

26.9

30.3
Front
mounting .8
31
Ø 27.8
Female Rear
17.9
36.5 mounting
33 maxi 26.9 Ø 31.3

Backshells (for Mated Connector Length: See Page 153)


32

31.4 27
Short version - 66.1 Short version - 72.1
Ø 33.3

Ø 33.3
35.2

Long version - 76.6 Long version - 82.6


Fig. 1 Fig. 2 Fig. 5 Fig. 6

60.0
Short version - 76.1 Short version - 86.1 77.2
46.0

Long version - 86.6 Long version - 96.6

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

97
UTO Series | Connector

1832 (Shell size 18, 32x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT018DCG* UTG618DCG* Shandles Toolkit

Gasket Crimp Tooling (without Shandles)

Part number / Neoprene


UTFD16B

Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set

Extraction Tool #20

Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT018DC

98
4A/50V
UTO Series | Connector
per IEC 61984

1832 (Shell size 18, 32x#20)


Contacts
Part number Max Max
#20 Contact type AWG
wire Ø insulator Ø
Male Female
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132

32

Electrical Characteristics UTO 1832 Derating Curves


Current (A)
10

UL
4A 250V UL94 V-0 8

Test
conditions 6
CSA
Contact used:
3A 250V UL94 V-0 Machined contacts
4

Wires used:
0.518mm²
IEC 2

4A 50V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

99
UTO Series | Connector

2235 (Shell size 22, 35x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 178

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT002235PH UT002235SH


receptacle IP68 & IP69K 96h UT002235PH6 UT002235SH6
IP67, IP68 & IP69K 48h UT062235PH UT062235SH
Plug
Contacts IP67, IP68 & IP69K 96h UT062235PH02(Black) UT062235SH02(Black)
supplied separately
see page 103 IP67 48h UT072235PH UT072235SH

Jam nut IP68 & IP69K 48h UT072235PH6 UT072235SH6


receptacle IP67 96h UT072235PH01 UT072235SH01
IP68 & IP69K 96h UT072235PH601 UT072235SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT022JCS UT022JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 15/24 UT022JCSL UT022JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S22JCS UT0S22JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S22JCSL UT0S22JCL

Metal cable clamp with strain relief (Fig.5) - 19.3 UT022AC


Metal shrink boot adaptor (Fig.6) - - UT022AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT022LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S22JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT022JCPGN

100
6A/150V
UTO Series | Connector
per IEC 61984

2235 (Shell size 22, 35x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
34.75 maxi 39.7 33 maxi 42
14.5
Male Male

39.5
Female Female
2.4
31.7 27.5 maxi
29 maxi

Jam Nut - UTO7 Panel Cut Out


39 maxi 49.2 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 34.8

31.7

36.7
Front
mounting .9
37
Ø 34.1
Female Rear
22.7
42.9 mounting
39 maxi 31.7 Ø 37.7

Backshells (for Mated Connector Length: See Page 153)

Short version - 77.1 Short version - 84.1


31.0 27 35
Ø 35.7

Ø 39.7
41.1

Long version - 88.4 Long version - 95.4


Fig. 1 Fig. 2 Fig. 5 Fig. 6

58.0
Short version - 90.6 Short version - 99.6 91.7
48.0

Long version - 101.9 Long version - 110.9

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

101
UTO Series | Connector

2235 (Shell size 22, 35x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT022DCG* UTG622DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD18B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT022DC

102
6A/150V
UTO Series | Connector
per IEC 61984

2235 (Shell size 22, 35x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

35

Electrical Characteristics UTO 2235 Derating Curves


Current (A)
30

UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

6A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

103
UTO Series | Connector

2238 (Shell size 22, 38x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 178

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT002238PH UT002238SH


receptacle IP68 & IP69K 96h UT002238PH6 UT002238SH6
IP67, IP68 & IP69K 48h UT062238PH UT062238SH
Plug
Contacts IP67, IP68 & IP69K 96h UT062238PH02(Black) UT062238SH02(Black)
supplied separately
see page 107 IP67 48h UT072238PH UT072238SH

Jam nut IP68 & IP69K 48h UT072238PH6 UT072238SH6


receptacle IP67 96h UT072238PH01 UT072238SH01
IP68 & IP69K 96h UT072238PH601 UT072238SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT022JCS UT022JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 15/24 UT022JCSL UT022JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S22JCS UT0S22JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S22JCSL UT0S22JCL

Metal cable clamp with strain relief (Fig.5) - 19.3 UT022AC


Metal shrink boot adaptor (Fig.6) - - UT022AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT022LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S22JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT022JCPGN

104
6A/150V
UTO Series | Connector
per IEC 61984

2238 (Shell size 22, 38x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
34.75 maxi 39.7 33 maxi 42
14.5
Male Male

39.5
Female Female
2.4
31.7 27.5 maxi
29 maxi

Jam Nut - UTO7 Panel Cut Out


39 maxi 49.2 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 34.8

31.7

36.7
Front
mounting .9
37
Ø 34.1
Female Rear
22.7
42.9 mounting
39 maxi 31.7 Ø 37.7

Backshells (for Mated Connector Length: See Page 153)

31.0 27
Short version - 77.1 Short version - 84.1

38
Ø 35.7

Ø 39.7
41.1

Long version - 88.4 Long version - 95.4


Fig. 1 Fig. 2 Fig. 5 Fig. 6

58.0
Short version - 90.6 Short version - 99.6 91.7
48.0

Long version - 101.9 Long version - 110.9

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

105
UTO Series | Connector

2238 (Shell size 22, 38x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT022DCG* UTG622DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD18B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT022DC

106
6A/150V
UTO Series | Connector
per IEC 61984

2238 (Shell size 22, 38x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

38

Electrical Characteristics UTO 2238 Derating Curves


Current (A)
30

UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

6A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

107
UTO Series | Connector

2041 (Shell size 20, 41x#20)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 178

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT0W02041PH UT0W02041SH


receptacle IP68 & IP69K 96h UT0W02041PH6 UT0W02041SH6
IP67, IP68 & IP69K 48h UT0W62041PH UT0W62041SH
Plug
Contacts IP67, IP68 & IP69K 96h UT0W62041PH02(Black) UT0W62041SH02(Black)
supplied separately
see page 111 IP67 48h UT0W72041PH UT0W72041SH

Jam nut IP68 & IP69K 48h UT0W72041PH6 UT0W72041SH6


receptacle IP67 96h UT0W72041PH01 UT0W72041SH01
IP68 & IP69K 96h UT0W72041PH601 UT0W72041SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT020JCS UT020JC

Cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 15/24 UT020JCSL UT020JCL

Shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S20JCS UT0S20JC

Shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S20JCSL UT0S20JCL

Metal cable clamp with strain relief (Fig.5) - 16.0 UT020AC


Metal shrink boot adaptor (Fig.6) - - UT020AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT020LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S20JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT020JCPGN

108
8A/80V
UTO Series | Connector
per IEC 61984

2041 (Shell size 20, 41x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
34.75 maxi 36.5 33 maxi 38.8
14.5
Male Male

Ø 36.5
Female Female
2.4
29.3 27.5 maxi
29 maxi

Jam Nut - UTO7 Panel Cut Out


39 maxi 46.0 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 31.6

29.3

33.5
Front
mounting .8
34
Ø 30.9
Female Rear
22.7
39.7 mounting
39 maxi 29.3 Ø 34.5

Backshells (for Mated Connector Length: See Page 153)

32.0 27
Short version - 74.8 Short version - 81.8
Ø 32.5

Ø 36.5
35.2

41
Long version - 84.6 Long version - 91.6
Fig. 1 Fig. 2 Fig. 5 Fig. 6

58.0
Short version - 88.3 Short version - 97.3 84.6
47.0

Long version - 98.1 Long version - 107.1

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

109
UTO Series | Connector

2041 (Shell size 20, 41x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT020DCG* UTG620DCG* Shandles Toolkit

Gasket Crimp Tooling (without Shandles)

Part number / Neoprene


UTFD17B

Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set

Extraction Tool #20

Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT020DC

110
8A/80V
UTO Series | Connector
per IEC 61984

2041 (Shell size 20, 41x#20)


Contacts
Part number Max Max
#20 Contact type AWG
wire Ø insulator Ø
Male Female
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132

41
Electrical Characteristics UTO 2041 Derating Curves
Current (A)
10

UL 9

3A 250V UL94 V-0 8

Test 7

conditions 6
CSA 5
Contact used:
2A 250V UL94 V-0 Machined contacts 4

Wires used: 3
0.518mm²
IEC 2

1
8A 80V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

111
UTO Series | Connector

2448 (Shell size 24, 48x#16)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 179

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT002448PH UT002448SH


receptacle IP68 & IP69K 96h UT002448PH6 UT002448SH6
IP67, IP68 & IP69K 48h UT062448PH UT062448SH
Plug
Contacts IP67, IP68 & IP69K 96h UT062448PH02(Black) UT062448SH02(Black)
supplied separately
see page 115 IP67 48h UT072448PH UT072448SH

Jam nut IP68 & IP69K 48h UT072448PH6 UT072448SH6


receptacle IP67 96h UT072448PH01 UT072448SH01
IP68 & IP69K 96h UT072448PH601 UT072448SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT024JCS UT024JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 15/24 UT024JCSL UT024JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S24JCS UT0S24JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S24JCSL UT0S24JCL

Metal cable clamp with strain relief (Fig.5) - 19.3 UT024AC


Metal shrink boot adaptor (Fig.6) - - UT024AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT024LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S24JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT024JCPGN

112
6A/160V
UTO Series | Connector
per IEC 61984

2448 (Shell size 24, 48x#16)


Dimensions
Square Flange - UTO0 Plug - UTO6
34.75 maxi 42.8 33 maxi 45.05
15.3
Male Male

Ø 42.6
Female Female
2.4
34.9 27.5 maxi
29 maxi

Jam Nut - UTO7 Panel Cut Out


41 maxi 53.4 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.9
Male
Ø 38.0

34.9

39.9
Front
mounting .2
41
Ø 37.3
Female Rear
23.6 mounting
46.0 34.9
41 maxi Ø 40.9

Backshells (for Mated Connector Length: See Page 153)

31.0 27
Short version - 82.4 Short version - 89.4
Ø 38.8

Ø 42.9
42.4

Long version - 92.4 Long version - 99.4


Fig. 1 Fig. 2 Fig. 5 Fig. 6
48
67.0
Short version - 95.9 Short version - 104.9 91.7
54.5

Long version - 105.9 Long version - 114.9

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

113
UTO Series | Connector

2448 (Shell size 24, 48x#16)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT024DCG* UTG624DCG* Shandles Toolkit

Gasket Dummy Contact #16 Crimp Tooling (without Shandles)

Part number / Neoprene Part number / Polyamide 6.6


UTFD19B SMSPKE0
Part number
See page 180 for more information Contacts Contact size
of head
RM/RC 28M1K(1) S16RCM20*
Extraction Tool #16 RM/RC 24M9K(1) S16RCM20*
RM/RC 20M13K(1) S16RCM20*
RM/RC 20M12K(1) S16RCM20*
RM/RC 16M23K(1) Standard contacts S16RCM16*
RM/RC 14M30K(1) #16
S16RCM14*
SM/SC 24ML1TK6(1) Ø 1.6mm S16SCM20*
SM/SC 20ML1TK6(1) S16SCM20*
Part number
SM/SC 16ML1TK6(1) S16SCML1*
RX2025GE1
SM/SC 14ML1TK6(1) S16SCML1*
SM/SC 16ML11TK6(1) S16SCML11*
RMDXK10D28K
RCDXK1D28K M10S1J
with die set &
RM/RC DX60xxD28K
Coaxial contacts stop bushing
RM/RC DXK10D28 + see page
york090 173 to 174
RM/RC DX60xxD28
(1): Example of plating, for other plating options see page 129
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT024DC

114
6A/160V
UTO Series | Connector
per IEC 61984

2448 (Shell size 24, 48x#16)


Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp

16-14 RM14M30K (1)


RC14M30K (1)
2.30 3.20

26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60


22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10
Stamped & Formed reeled contacts 18-16 SM16M1TK6 (1)(2)
SC16M1TK6 (1)(2)
- 3.20
See note (2) for loose piece
18-16 SM16M11TK6(1)(2) SC16M11TK6(1)(2) - 3.00
14 SM14M1TK6 (1)(2)
SC14M1TK6 (1)(2)
- 3.20
PCB

Machined (3) - RM20M12E8K(1) RC20M12E84K(1) - -

Cable Multipiece RMDXK10D28 RCDXK1D28 - -


Cable Monocrimp see pages RMDX60xxD28 RCDX60xxD28 - -
Coaxial

131, RMDXK10D28 + RCDXK1D28 +


Twisted pair Multipiece 168 to 174 - -
york090 york090
Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - -
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 2448 Derating Curves


Current (A) 48
30

UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5

6A 160V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

115
UTO Series | Connector

2255 (Shell size 22, 55x#20)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 179

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT0W02255PH UT0W02255SH


receptacle IP68 & IP69K 96h UT0W02255PH6 UT0W02255SH6
IP67, IP68 & IP69K 48h UT0W62255PH UT0W62255SH
Plug
Contacts IP67, IP68 & IP69K 96h UT0W62255PH02(Black) UT0W62255SH02(Black)
supplied separately
see page 119 IP67 48h UT0W72255PH UT0W72255SH

Jam nut IP68 & IP69K 48h UT0W72255PH6 UT0W72255SH6


receptacle IP67 96h UT0W72255PH01 UT0W72255SH01
IP68 & IP69K 96h UT0W72255PH601 UT0W72255SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT022JCS UT022JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 15/24 UT022JCSL UT022JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S22JCS UT0S22JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S22JCSL UT0S22JCL

Metal cable clamp with strain relief (Fig.5) - 19.3 UT022AC


Metal shrink boot adaptor (Fig.6) - - UT022AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT022LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S22JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT022JCPGN

116
3A/80V
UTO Series | Connector
per IEC 61984

2255 (Shell size 22, 55x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
34.75 maxi 39.7 33 maxi 42
14.5
Male Male

39.5
Female Female
2.4
31.7 27.5 maxi
29 maxi

Jam Nut - UTO7 Panel Cut Out


39 maxi 49.2 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.2
Male
Ø 34.8

31.7

36.7
Front
mounting .9
37
Ø 34.1
Female Rear
22.7
42.9 mounting
39 maxi 31.7 Ø 37.7

Backshells (for Mated Connector Length: See Page 153)

31.0 27
Short version - 77.1 Short version - 84.1
Ø 35.7

Ø 39.7
41.1

Long version - 88.4 Long version - 95.4


Fig. 1 Fig. 2 Fig. 5 Fig. 6

58.0
Short version - 90.6 Short version - 99.6 91.7 55
48.0

Long version - 101.9 Long version - 110.9

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

117
UTO Series | Connector

2255 (Shell size 22, 55x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT022DCG* UTG622DCG* Shandles Toolkit

Gasket Crimp Tooling (without Shandles)

Part number / Neoprene


UTFD18B

Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set

Extraction Tool #20

Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT024DC

118
3A/80V
UTO Series | Connector
per IEC 61984

2255 (Shell size 22, 55x#20)


Contacts
Part number Max Max
#20 Contact type AWG
wire Ø insulator Ø
Male Female
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 2255 Derating Curves


Current (A)
10

UL 9

3A 250V UL94 V-0 8


55
Test 7

conditions 6
CSA 5
Contact used:
2A 250V UL94 V-0 Machined contacts 4
Wires used: 3
0.518mm²
IEC 2

1
3A 80V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

119
UTO Series | Connector

2461 (Shell size 24, 61x#20)

Layout

OR OR OR OR
WITH

Connector Part Numbers Drilling pattern see page 179

Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert

Square flange IP67 96h UT0W02461PH UT0W02461SH


receptacle IP68 & IP69K 96h UT0W02461PH6 UT0W02461SH6
IP67, IP68 & IP69K 48h UT0W62461PH UT0W62461SH
Plug
Contacts IP67, IP68 & IP69K 96h UT0W62461PH02(Black) UT0W62461SH02(Black)
supplied separately
see page 123 IP67 48h UT0W72461PH UT0W72461SH

Jam nut IP68 & IP69K 48h UT0W72461PH6 UT0W72461SH6


receptacle IP67 96h UT0W72461PH01 UT0W72461SH01
IP68 & IP69K 96h UT0W72461PH601 UT0W72461SH601
* Other discrimination keying option, see page 180

Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT024JCS UT024JC

Short cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.2)
- 15/24 UT024JCSL UT024JCL

Short shielded cable gland with strain relief nut


for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S24JCS UT0S24JC

Short shielded cable gland with large strain relief nut


for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S24JCSL UT0S24JCL

Metal cable clamp with strain relief (Fig.5) - 20.6 UT024AC


Metal shrink boot adaptor (Fig.6) - - UT024AD
Metal right angle cable clamp with strain relief nut (Fig.7) - 17/30 UT024LPGN
Shielded cable clamp with plastic strain relief nut (Fig.8) 3 17/29.5 UT0S24JCPGN
Cable clamp with plastic strain relief nut (Fig.8) - 17/29.5 UT024JCPGN

120
3A/80V
UTO Series | Connector
per IEC 61984

2461 (Shell size 24, 61x#20)


Dimensions
Square Flange - UTO0 Plug - UTO6
34.75 maxi 42.8 33 maxi 45.05
15.3
Male Male

Ø 42.6
Female Female
2.4
34.9 27.5 maxi
29 maxi

Jam Nut - UTO7 Panel Cut Out


41 maxi 53.4 Square flange receptacle - UTO0 Jam nut receptacle - UTO7
Ø 3.9
Male
Ø 38.0

34.9

39.9
Front
mounting .2
41
Ø 37.3
Female Rear
23.6 mounting
46.0 34.9
41 maxi Ø 40.9

Backshells (for Mated Connector Length: See Page 153)

31.0 27
Short version - 82.4 Short version - 89.4
Ø 38.8

Ø 42.9
42.4

Long version - 92.4 Long version - 99.4


Fig. 1 Fig. 2 Fig. 5 Fig. 6

67.0
Short version - 95.9 Short version - 104.9 91.7

61
54.5

Long version - 105.9 Long version - 114.9

Fig. 3 Fig. 4 Fig. 7 Fig. 8

Note: all dimensions are in mm

121
UTO Series | Connector

2461 (Shell size 24, 61x#20)


Accessories and Tooling
Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit

Part number Part number Part number Part number


UT024DCG* UTG624DCG* Shandles Toolkit

Gasket Crimp Tooling (without Shandles)

Part number / Neoprene


UTFD19B

Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES

+ =
Handle Head Complete set

Extraction Tool #20

Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT024DC

122
3A/80V
UTO Series | Connector
per IEC 61984

2461 (Shell size 24, 61x#20)


Contacts
Part number Max Max
#20 Contact type AWG
wire Ø insulator Ø
Male Female
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp

26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60

Stamped & Formed reeled contacts 26-24 SM24W3S26 (1)(2)


SC24W3S25 (1)(2)
- 0.90-1.60
See note (2) for loose piece
22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10
22-20 SM20W3S26 (1)(2)
SC20W3S25 (1)(2)
- 1.20-2.10
PCB

Machined (3) - RMW5016K RCW5016K - -

(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132

Electrical Characteristics UTO 2461 Derating Curves


Current (A)
10

UL 9

3A 250V UL94 V-0 8

Test 7

conditions 6
CSA
2A 250V UL94 V-0 Contact used:
5

4
61
Machined contacts
Wires used: 3
0.518mm²
IEC 2

1
3A 80V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use

123
UTO SERIES

© 2013 SOURIAU - SOURIAU is a registered trademark


UTO Series

Contacts
Description ................................................................................................................ 126

Contact Plating Selector Guide ................................................................................. 127

Contact Selector Guide ............................................................................................. 128

Packaging .................................................................................................................. 128

Crimp Contacts ......................................................................................................... 129

#16 Coaxial Contacts ................................................................................................ 131

PCB Contacts ............................................................................................................ 132

Fiber Optic Contacts ................................................................................................. 133

125
UTO Series | Contacts

Contacts

Description

The UTO series is delivered without contacts and offers the unique feature to use the same style contact in any layout with the same active part
size (i.e. #20, #16, #12, etc.). This provides our customers with an easy solution to buy only one type of contact to equip all their connectors
even if housings/shell sizes are different.

This provides the benefit of standardization and subsequent reduced inventory costs. In addition, it eliminates the need for added tooling and
simplifies the assembly process. Souriau contacts are designed for simple snap-in installation and further eliminate the need for insertion
tooling.

In addition to the below “crimp” style contact options, the UTO series can also be equipped with PCB contacts.

Crimp contacts are available in different versions:

• machined • stamped & formed • coaxial • fiber optic

126
UTO Series | Contacts

Contact Plating Selector Guide

Once the contact size has been selected, the next step is to decide on which type to use. Souriau offers two main types of electrical contacts:
• Machined
• Stamped & Formed

Machined contacts are generally chosen as a better solution for power applications or when lower quantities are needed.
Stamped & formed contacts offer the ability to be crimped automatically which makes them more suitable for high volume production
applications.

The next decision to make is: What plating should I choose?

The graph below can help guide you to plating recommendations based on application, mating cycles and current/voltage needs.

Note: do not mix different plating (i.e. tin plated pin contacts with gold plated socket contacts).

Number of
Vibration cycles

250

Gold flash

0.4μm of gold

Contacts
Silver
min
100

Tin

Current /
1Amp
5mV Voltage

Contact #20 #12


size #16 #8

127
UTO Series | Contacts

Contact Selector Guide

Contacts supplied separately


Electrical characteristics: contact resistance Available plating options

Machined < 6mΩ A 2μm Nickel + 2μm Ag


#20
Ø1mm J Gold flash over Nickel 2μm mini
Stamped & formed < 6mΩ
K 0.4 μm Gold over 2 μm Nickel mini
Machined < 3mΩ Active part: Gold flash over Nickel
#16 S31 Crimp area: 1.3μm Tin mini over Nickel
Ø1.6mm Other: 1.3μm Tin mini
Stamped & formed < 6mΩ
Active part: 0.75μm Gold mini over Nickel
#12 S18 Crimp area: 1.3μm Tin mini over Nickel
Machined < 5mΩ
Ø2.4mm Other: 1.3μm Tin mini
#8 S25 Active part: 0.75μm Au over Nickel
Machined < 5mΩ
Ø3.6mm S26 Crimp area: flash Au over Nickel
TK6 0.5μm - 2.5μm Sn pre-plated
D70 Superseded by S31
S6 Superseded by S18
Other platings on request (contact supplied separately)
T Tin 3μm (-0/+2) over 1.3μm Nickel mini
D28* 0.75μm mini Gold over 2μm Nickel mini
* For Coax contacts only

Packaging

Due to the wide variety of applications, contact packaging is offered for small series (bulk package) and high volume production (reeled contacts):

Size contacts #20 & #16

• 25 pieces loose package • 50 pieces bulk package • 1,000 pieces • 3,000 pieces reeled • 2,000 pieces reeled
(stamped & formed (machined contacts) bulk package (stamped & formed (machined contacts)
contacts) (machined contacts) contacts) Size #16 only

Size contacts #12 & #8

• 100 pieces bulk package


(machined contacts)

Note: 1,000 pieces bulk package available by adding 1000 at the end of the part number: e.g. RC16M23K1000
2,000 pieces reeled package available by adding K at the beginning of the part number: e.g. KRC16M23K

128
UTO Series | Contacts

Crimp Contacts

Standard Version

Wire size Part number Available


Contact Max Max
Type plating
size AWG mm² Male Female wire Ø insulator Ø
see page 128
Machined 26-24 0.13-0.20 RM24W3K RC24W3K 1.58 max K
SM24W3- (1)
SC24W3- (1) TK6
Stamped &
26-24 0.13-0.25 0.89-1.58 S25 (female)
Formed
SM24WL3-(2) SC24WL3-(2) S26 (male)
#20
Ø1 mm
Machined 22-20 0.32-0.52 RM20W3K RC20W3K 1.58 max K
SM20W3- (1)
SC20W3- (1) TK6
Stamped &
22-20 0.35-0.5 1.17-2.08 S25 (female)
Formed
SM20WL3-(2) SC20WL3-(2) S26 (male)
Machined 20-18 0.50-0.93 RM18W3K RC18W3K 2.10 max K
Machined 30-28 0.05-0.08 RM28M1- RC28M1- 0.55 1.1 K, J
Machined 26-24 0.13-0.2 RM24M9- RC24M9- 0.8 1.6 K, J
Stamped & SM24M1- (1)
SC24M1- (1)
No insulation
26-24 0.13-0.25 0.89-1.28 S31, S18, TK6
Formed SM24ML1-(2) SC24ML1-(2) grip
RM20M13- RC20M13- 1.8
Machined 22-20 0.32-0.52 1.18 K, J
RM20M12- RC20M12- 2.2
Stamped & SM20M1-(1) SC20M1-(1) No insulation
#16 22-20 0.35-0.5 1.17-2.08 S31, S18, TK6

Contacts
Formed SM20ML1-(2) SC20ML1-(2) grip
Ø1.6
mm Machined 20-16 0.52-1.5 RM16M23- RC16M23- 1.8 3.2 K, J
Stamped & SM16M1-(1) SC16M1-(1) No insulation
18-16 0.8-1.5 3.0 S31, S18, TK6
Formed SM16ML1-(2) SC16ML1-(2) grip
Stamped & SM16M11-(1) SC16M11-(1) Insulation
18-16 0.8-1.5 2.0-3.0 S31, S18, TK6
Formed SM16ML11-(2) SC16ML11-(2) grip
Machined 16-14 1.5-2.5 RM14M30- RC14M30- 2.28 3.2 K, J
Stamped & SM14M1- (1)
SC14M1- (1)
No insulation
14 2.0-2.5 3.2 S31, S18, TK6
Formed SM14ML1-(2) SC14ML1-(2) grip
22 0.13-0.4 82911457N- 82911456-
20 0.5 82911459N- 82911458-
#12 18 0.75-1.0 82911461N- 82911460-
Ø2.4 Machined - 4.9 A, K
mm 16 1.5 82911463N- 82911462-
14 2.5 82911465N- 82911464-
12 4 82911467N- 82911466-
16 1.5 82913601A 82913600A

#8
14 2.5 82913603A 82913602A
Ø3.6 Machined 12 4 82913605A 82913604A - 6.5 A
mm
10 6.0 82913607A 82913606A
8 10.0 82913609A 82913608A
(1) contact reeled (2) loose contact Note: all dimensions are in mm
Exemple: RM24W3K - Size #20, Machined, AWG24 wire.

129
UTO Series | Contacts

Crimp Contacts (Continued)

First Mate Last Break Contacts

Max Max Color band Available


Contact Wire size Part number
Type wire Ø insulator Ø plating
size
AWG mm² Male Female (mm) (mm) Front Rear see p. 128
30-28 0.05-0.08 RM28M1GE1- 0.55 1.1 - Red
#16 26-24 0.13-0.2 RM24M9GE1- 0.8 1.6 Red Red
Ø1.6 mm RM20M13GE1- 1.8 Black Red
Machined 22-20 0.32-0.52 - 1.18 K or J
Longer male RM20M12GE1- 2.2 Blue Red
contact
(+1mm) 20-16 0.52-1.5 RM16M23GE1- 1.8 3.2 - Red
16-14 1.5-2.5 RM14M30GE1- 2.28 - - Red
30-28 0.05-0.08 RC28M1GE7- 0.55 1.1 - Blue
#16 26-24 0.13-0.2 RC24M9GE7- 0.8 1.6 Red Blue
Ø1.6 mm RC20M13GE7- 1.8 Black Blue
Machined 22-20 0.32-0.52 - 1.18 K or J
Shorter RC20M12GE7- 2.2 Blue Blue
female contact
(-0.7mm) 20-16 0.52-1.5 RC16M23GE7- 1.8 3.2 - Blue
16-14 1.5-2.5 RC14M30GE7- 2.28 - - Blue

How to make FMLB / LMFB connection

Contact 1
Standard male Standard female
Longer male contact
contact contact First Mate Last Break contacts should be
Contact 2
chosen only if the cavity is not marked with
the ground symbol. For cavities marked
with the ground symbol, standard contacts
Standard male
will fulfill the same role as a first mate, last
contact
break contact used in a standard cavity.

Standard female
contact
FMLB

Shorter female
contact Ground symbol
LMFB

Note: all dimensions are in mm

130
UTO Series | Contacts

#16 Coaxial Contacts

Coaxial Contact Range

souriau provides 2 types of coaxial contacts suitable for 50 or 75Ω, coaxial cable or twisted pair cable.

Monocrimp coaxial contact


• The monocrimp one-piece coaxial contacts offer high reliability plus the econo-
mic advantage of a 95% reduction in installation time over conventional assembly
methods.

• This economy is achieved by simultaneously crimping both the inner conductor


and outer braid or drain wire.

Multipiece crimp coaxial contact


• The inner conductor and outer braid is crimped individually.

• The thermoplastic insulating bushing in the outer body is designed to accept


and permanently retain the inner contact.

• An outer ferrule is used to connect the braid to the outer contact and provide
cable support to ensure against bending and vibration.

Suitable for Coaxial cable or Twisted cable


• For jacket diameter from 1.78 to 3.05mm • For jacket diameter from 0.64 to 1.45mm

Contacts
Inner conductor up to 2.44mm diameter Inner conductor from AWG30 to AWG24

Contacts for coaxial cable summary

Contact range
Contact part number with
Contact type Cabling notice
Male contact Female contact cable combination

Multipiece RMDXK10D28 RCDXK1D28 See pages 172 & 173


See page 168
Monocrimp RMDX60xxD28 RCDX60xxD28 See page 174

Contacts for twisted pairs cable summary

Contact range Contact part number with


Contact type Cabling notice
Male contact Female contact cable combination

RMDXK10D28 RCDXK1D28
Multipiece See page 170
+ YORK090 + YORK090 See page 169
Monocrimp RMDX60xxD28 RCDX60xxD28 See page 171

131
UTO Series | Contacts

PCB Contacts

PCB Contacts

PCB soldering
The UTO series can be used in a wave soldering process, but not reflow soldering process.
All high temperature processes are prohibited.

Part number Plating


Contact size Type
Male Female see page 128

#20 Short version RMW50A7K RCW50A7K


K
Ø1mm Long version RMW5016K RCW5016K
Short version RM20M12E8- RC20M12E8-
#16
RC20M12E83- K or J
Ø1.6mm Long version RM20M12E83-
RC20M12E84-
#8 82911685NPC 82911684NPC 2 μm Ni
-
Ø3.6mm 82911685NAPC 82911684NAPC 2 μm Ni + 0.6 μm Ag

A A
A G G G

Nominal length G (mm)


Dimension of dipsolder contacts out of connector
(contacts to be ordered separately).

UTO0/UTOW0
UTO7/UTOW7 UTO7/UTOW7
UTO0 and UTOW0 Male insert Female insert

Pin contact Socket contact


Connector size A (mm) RM20M RM20M RMW RMW RC20M RC20M RC20M RCW RCW
12E8K* 12E83K* 50A7K 5016K 12E8K* 12E83K* 12E84K* 50A7K 5016K
10 21.5 3.9 9.1 9.5 10.3 3.2 8.4 11.9 9.8 10.5
12 21.5 3.9 9.1 9.5 10.3 3.2 8.4 11.9 9.8 10.5
14 21.5 3.9 9.1 9.5 10.3 3.2 8.4 11.9 9.8 10.5
16 21.5 3.9 9.1 9.5 10.3 3.2 8.4 11.9 9.8 10.5
18 21.5 3.9 9.1 9.5 10.3 3.2 8.4 11.9 9.8 10.5
20 19.9 3.9 9.1 9.2 10.3 - 6.2 9.7 7.6 8.3
22 19.9 3.9 9.1 9.2 10.3 - 6.2 9.7 7.6 8.3
24 19.1 3.9 9.1 9.2 10.3 - 6.2 9.7 7.6 8.3
UTO7 and UTOW7
Pin contact
Connector size A (mm) RM20M RM20M RMW RMW RC20M RC20M RCW RCW
12E8K* 12E83K* 50A7K 5016K 12E84K* 12E86K* 50A7K 5016K
10 14.9 3.9 9.1 9.5 10.4 4.6 8 2.4 3.0
12 14.9 3.9 9.1 9.5 10.4 4.6 8 2.4 3.0
14 14.9 3.9 9.1 9.5 10.4 4.6 8 2.4 3.0
16 14.9 3.9 9.1 9.5 10.4 4.6 8 2.4 3.0
18 14.9 3.9 9.1 9.5 10.4 4.6 8 2.4 3.0
20 15.4 - 5 5 6 - 3.6 - -
22 15.4 - 5 5 6 - 3.6 - -
24 16 - 3.6 3.6 4.6 - 2.2 - -
* Plating indication see page 128

Note: all dimensions are in mm

132
UTO Series | Contacts

Fiber Optic Contacts

Description

Size 16 fiber optic contacts for UTO and other TRIM TRIO® connectors
Size 16 fiber optic contacts are designed for the integration of optical links in UTO and other TRIM TRIO® cable connectors.

The Fiber optic contacts are designed to accommodate:


• Plastic Optical Fiber (POF) 1 mm core and 2.2 mm jacket

Typical features and benefits are:


• Socket contact is spring loaded to avoid any air gap between the two optical faces.
• Low insertion loss is provided by high precision pieces.
• Single jumpers, multiway harness and active device housings can be supplied regarding customer requirement.

Technical Characteristics

Performance
• Fiber type:.........................................................................................................POF
• Wave length:................................................................................................... 650 nm
• Optical insertion loss (typ.):.......................................................................... 2 dB max.
• Jacketed external diameter:............................................................................2.2mm
• Temperature range:..................................................................................-25°C to +70°C
• Cable retention:.................................................................................................49N
• Mating cycles without cleaning:......................................................................... 50
• Max. mating cycles:........................................................................................... 500

Contacts
Construction
• Contact body: Copper alloy

Connector accommodation
Any TRIM TRIO® size 16 contact can be used in any contact position in any connector in the TRIM TRIO® size 16 interconnection system:
UTP, UTS, UTG, UTO.

133
UTO Series | Contacts

Fiber Optic Contacts (Continued)

Ordering Information

POF Contacts (Plastic Optical Fiber)


Male contact......................................... RMPOF1000 Female contact................................... RCPOF1000B

POF Contact (Plastic Optical Fiber)

STANDARD TOOLING KIT - P/N 80MS0004 SPECIFIC TOOLING LIST - Can only be ordered separately
The standard tooling kit is made of the part numbers below
that can be ordered separately as well.

Part numbers Descriptions Part numbers Descriptions

80WD0005 Stripping tool 80WG0010 Needle

80WD0025
Automatic stripping tool for Ø 0.5 mm, 80WG0015 Capsule
0.6 mm, 0.7 mm & 3.8 mm
80WG0016 Syringe
80WM0006 Ruler
80WN0005 Dry air spray
80WP0005 Polishing plate
80WN0006 Optical paper
80WP0013 Non slip base (to hold the polishing plate)
80WN0012 Dropper bottle
80WP0014 Polishing disk (grain size 9µm)
80WN0008 Wiping solvent
80WP0018 Polishing tool
80WP0019 Polishing disk (grain size 30µm)
80WS0002 Crimping plier

134
UTO Series | Contacts

Contacts

135
UTO SERIES

© 2013 SOURIAU - SOURIAU is a registered trademark


UTO Series

Technical Information
Tooling ..................................................................................................................... 139

Crimping Instructions .............................................................................................. 140

Handle & Interchangeable Heads ........................................................................... 142

Extraction Tools ....................................................................................................... 143

Dimensions Overmoulded Harnesses ..................................................................... 143

Assembly Instructions .............................................................................................. 144

Mated Connector Length ........................................................................................ 153

Rated Current & Working Voltage ........................................................................... 155

Shielding Effectiveness/Corrosion ........................................................................... 156

UL94 + UL1977 ........................................................................................................ 157

IEC 61984 & IP Codes Explained ............................................................................ 160

IEC 61140 Explained ............................................................................................... 162

What is NEMA Rating ? ........................................................................................... 163

Ethernet for the Layman .......................................................................................... 164

137
UTO Series | Technical Information

Automatic Crimping Tools

Mecal is a leader in manufacturing tooling for The extreme environment interconnect specialist
crimping terminals over a stripped wire. “from deep sea to deep space”.
Established in 1976, Mecal has become one of the SOURIAU designs, manufactures and markets high
world's leading companies dedicated to the design performance interconnect solutions for severe
and manufacture of semi automatic production tools environments dedicated to the aerospace, defense,
for strip fed, open barrel crimp terminals, serving the light and heavy industry markets.
Automotive, Telecom and Datacom industries.

SOURIAU has been working in partnership with Mecal for many years. With sales offices located in all major
industrial regions of the world, the combined strengths of both organisations has resulted in a truly global
solution to all your production tooling needs.

Mini Applicator Stripper Presses

Mecal sales network:


www.mecal.net/eng/retevendita.php

138
UTO Series | Technical Information

Tooling

Crimp Tool Table

Standard contacts
Contact size Part number Head* Handles* Extraction tools
RM/RC 24W3K
RM/RC 20W3K S20RCM
#20 RM/RC 18W3K
Ø 1mm
RX20D44
SM 24WL3S*(1)
SC 24WL3S*(1) S20SCM20
SM/SC 20WL3S*(1)
RM/RC 28M1*
RM/RC 24M9*
S16RCM20
RM/RC 20M13* SHANDLES
RM/RC 20M12*
RM/RC 16M23* S16RCM16
#16
Ø 1.6mm
RM/RC 14M30* S16RCM14 RX2025GE1
SM/SC 24ML1*
S16SCM20
SM/SC 20ML1*
SM/SC 16ML1*
S16SCML1
SM/SC 14ML1*
SM/SC 16ML11* S16SCML11
(1) loose contact * Endurance of SHANDLES & Head tools = 50,000 cycles

Tool with separate locator


Contact size Part number Extraction tools
Hand tool Positioner + locator setting
82911457N* / 82911456* 1-2
82911459N* / 82911458* 2
#12 82911461N* / 82911460* 2
Ø 2.4mm
M317 VGE10077A 51060210924
82911463N* / 82911462* 3
82911465N* / 82911464* 3
82911467N* / 82911466* 4
82913601A / 82913600A 3
82913603A / 82913602A 3
#8
Ø 3.6mm
82913605A / 82913604A M317 VGE10078A 4 51060210936
82913607A / 82913606A 5
82913609A / 82913608A 6/7

Technical Information
* see page 129 for plating options and other contact details

Specific contacts (First mate Last break contacts)


Hand tools Tool with separate locator
Contact size Part number* Extraction tools
(SHANDLES) head Hand tool Positioner + locator setting
RM28M1GE1K
#16 RM24M9GE1K S16RCM20
Ø 1.6mm RM20M13GE1K
Longer RM RM16M23GE1K
RM20M12GE1K S16RCM16 MH860 MH86186 6/8
contact
RM14M30GE1K S16RCM14
RC28M1GE7K 4/6 RX2025GE1
#16 RC24M9GE7K 5/6
S16RCM20
Ø 1.6mm RC20M13GE7K MH860 MH86164G 5/7
Shorter RC RC20M12GE7K

contact RC16M23GE7K S16RCM16 6/8


RC14M30GE7K S16RCM14 M317 UH25 3
* see page 130 for plating options and other contact details

Coaxial contacts
See coax contacts details on page 131 and cabling notice pages 170 to 174.

139
UTO Series | Technical Information

Crimping Instructions

Wire Stripping Crimp Version

Part number Stripping


length L
Male Female (mm)
Machined contact #20 - Ø 1mm
RM24W3- / RM20W3- RC24W3- / RC20W3-
4.8
RM18W3- RC18W3-
#16 - Ø 1.6mm
RM28M1- / RM24M9- RC28M1- / RC24M9-
4.8
RM20M13- / RM20M12- RC20M13- / RC20M12-
RM16M23- /RM14M30- RC16M23- /RC14M30- 7.1
#12 - Ø 2.4mm
L 8291 1457- / 8291 1459- 8291 1456- / 8291 1458-
8291 1461- / 8291 1463- 8291 1460- / 8291 1462- 7 to 8
8291 1465- / 8291 1467- 8291 1464- / 8291 1466-
#8 - Ø 3.6mm
8291 3601- / 8291 3603- 8291 3600- / 8291 3602-
8291 3605- / 8291 3607- 8291 3604- / 8291 3606- 6.5 to 7.5
8291 3609- 8291 3608-
Stamped & formed #16 - Ø 1.6mm
With insulation support SM24M1- / SM24ML1- SC24M1- / SC24ML1-
4
SM20M1- / SM20ML1- SC20M1- / SC20ML1-
SM16M11- / SM16ML11- SC16M11- / SC16ML11- 4.65
L #20 - Ø 1mm
SM24W3- / SM24WL3- SC24W3- / SC24WL3-
4
SM20W3- / SM20WL3- SC20W3- / SC20WL3-
Without insulation support #16 - Ø 1.6mm

L
SM16M1- / SM16ML1- SC16M1- / SC16ML1- 6.35

SM14M1- / SM14ML1- SC14M1- / SC14ML1- 6.35


Note: See page 129 for plating options and other contact details

140
UTO Series | Technical Information

Crimping

One of the key factors which affects the performance of a connector is - No health risk from heavy metal and flux steam
the way contacts are terminated. Crimped connections are nowadays - Preservation of conductor flexibility behind the crimped
seen as the best solution to ensure quality throughout the lifetime of connection
the product. Here are some reasons why we recommend this method - No burnt, discolored and overheated wire insulation
of termination for UTO connectors: - Good connections with reproducible electrical and mechanical
performances
Advantages (Extract from the IEC 60352-2): - Easy production control.
- Efficient processing of connections at each production level
- Processing by fully-automatic or semi- automatic crimping To ensure that the crimp tooling is performing according to original
machines, or with hand operated tools specifications, it is important to carry out regular checks. A common
- No cold-soldered joints way to check the performance of tooling is with a simple pull test,
- No degradation of the spring characteristic of female contacts ideally using a dedicated electric pull tester. Minimum recommended
by the soldering temperature pull forces are indicated in the tables below:

Stamped & Formed

H
Machined
contact
contact
W W

Active Die Wire Tensile Height Width


Section Tooling head
contact Contact type location section straight (mm) (mm)
(mm²) p/n
part on heads range test (mini) H (±0.075) W (±0.075)
RM24W3K AWG 26 0.12 min 15 N
26/24 0.95 1.27
Machined RC24W3K AWG 24 0.25 max 32 N
contacts size RM20W3K AWG 22 0.32 min 40 N
22/20 1.26 1.78 S20RCM
#20 RC20W3K AWG 20 0.50 max 60 N
Ø 1 mm
RM18W3K AWG 20 0.50 max 60 N
20/18 1.35 1.86
RC18W3K AWG 18 0.82 max 90 N
S&F SM24WL3TK6* AWG 26 0.12 min 15 N
26/24 0.80 1.49
contacts size SC24WL3TK6* AWG 24 0.25 max 32 N
#20
S20SCM20
SM20WL3TK6* AWG 22 0.32 min 40 N
Ø 1 mm 22/20 1.01 1.53
SC20WL3TK6* AWG 20 0.50 max 60 N
RM28M1K* AWG 30 0.05 min 11 N
30/28 1.14 1.41
RC28M1K* AWG 28 0.08 max 11 N
RM24M9K* AWG 26 0.12 min 15 N
26/24 1.15 1.41
RC24M9K* AWG 24 0.25 max 32 N
S16RCM20
RM20M13K* AWG 22 0.32 min 40 N

Technical Information
Machined RC20M13K* AWG 20 0.50 max 60 N
contacts size 22/20 1.26 1.76
#16 RM20M12K* AWG 22 0.32 min 40 N
Ø 1.6 mm RC20M12K* AWG 20 0.50 max 60 N
20 AWG 20 0.50 max 60 N 1.66 2.18
RM16M23K*
18 AWG 18 0.82 max 90 N 1.80 2.28 S16RCM16
RC16M23K*
16 AWG 16 1.50 max 150 N 1.96 2.43
RM14M30K* 16 AWG 16 1.50 min 150 N 2.10 2.68
S16RCM14
RC14M30K* 14 AWG 14 2.50 min 230 N 2.30 2.78
SM24ML1TK6* AWG 26 0.12 min 15 N
26/24 0.84 1.50
SC24ML1TK6* AWG 24 0.25 max 32 N
S16SCM20
SM20ML1TK6* AWG 22 0.32 min 40 N
22/20 1.02 1.54
S&F SC20ML1TK6* AWG 20 0.50 max 60 N
contacts size SM16ML11TK6* 18 AWG 18 0.75 min 90 N 1.32 2.09
S16SCML11
#16 SC16ML11TK6* 16 AWG 16 1.50 max 150 N 1.36 2.10
Ø 1.6 mm
SM16ML1TK6* 18 AWG 18 0.75 min 90 N 1.49 2.02
SC16ML1TK6* 16 AWG 16 1.50 max 150 N 1.7 2.05
S16SCML1
SM14ML1TK6*
14 AWG 14 2.50 max 230 N 1.79 2.58
SC14ML1TK6*
*: example of plating options, for other plating see page 129

141
UTO Series | Technical Information

Handle & Interchangeable Heads

User Guide

1) Fully close then release the tool, keep it open. 5) Place conductors, with no deteriorations, in the bucket
Open the 2 pins. contact. All strands to be located in the crimp bucket.

2) Choose the adapter head (sold separately), keep vertical and 6) Position the contact in the bottom of the tool by checking
slide it into the handle until the mechanical end. its orientation.

3) Close the two pins simultaneously to maintain the head. 7) To crimp contact assembly-cable, tighten sharply the clip
to the end of the mechanism.

8) To control crimp quality, slighty pull cable with two fingers


4) Strip the cable properly checking the size recommended
to control retention.
in the catalog on page 140.

142
UTO Series | Technical Information

Extraction Tools
RX2025GE1
Contact size Extractor

#20 RX20D44
#16 RX2025GE1 51060210936

#12 51060210924
#8 51060210936

RX20D44

51060210924

Contact Extraction Instructions


Place the tool into the cavity from front face of the connector, push on the handle, then remove the contact.

Dimensions Overmoulded Harnesses

Technical Information
L
Shell UTO0 UTO7
L1 size L max L1 max L2 max L3 max L max L1 max L2 max L3 max
8 42.8 36.8 80.7 57.2 46.8 36.8 85.8 57.2
10 55.8 50.3 98.6 92 60.5 50.3 102.7 92
12 57.1 51.4 99.3 93.7 61.4 51.4 106.4 93.7
14 62.5 56.3 100.3 94.6 67.6 56.3 104.8 94.6

L2

L3

Note: all dimensions are in mm

143
UTO Series | Technical Information

Assembly Instructions

UTO0 Assembly (Mounting Suggestion)

• Strip wires and crimp contacts (see pages 140 & 141)
• Insert contacts into connector cavities (insert manually or use tool RTM205 crimp contacts)
• Place receptacle in the panel cut-out
• Secure receptacle with screws (not supplied)
Tighten screws: M2.5 for size connectors 10 to 22, M3 for size connectors 24
(recommended torque: see table below)
• For complete sealing of the system use optional gasket and sealed screw solution (not sold by Souriau).

Front mounting : Crimp version Rear mounting : Crimp version

Gasket (optional)

Gasket (optional)

3mm max 3mm max Receptacle flange

Receptacle
flange
Panel thickness:
Panel 2.5mm max

Shell size

10 12 14 16 18 20 22 24
Screws tightening
0.30/0.40 0.30/0.40 0.30/0.40 0.30/0.40 0.35/0.45 0.50/0.60 0.55/0.65 0.55/0.65
torque (Nm)

144
UTO Series | Technical Information

UTO7 Assembly (Mounting Suggestion)

• Strip wires and crimp contacts (see pages 140 & 141)
• Insert contacts into connector cavities (insert manually or use tool Panel thickness
RTM205 crimp contacts )
• Seat o-ring, place receptacle in the panel cut-out Jam nut
• Tighten jam nut

Jam nut Exterior Panel


Ø Wire
Shell size torque jam nut thickness
max (mm)
(Nm) dim. (mm) max (mm)
O-ring
10 6 22.2 3.2 3.2
12 9 27.0 3.2 3.2
14 10 32.0 3.2 3.2
16 13 33.3 3.2 3.2
18 20 36.5 3.2 3.2
20 23 39.7 3.2 6.4
22 25 42.9 3.2 6.4
24 26 46.0 3.2 6.4

Technical Information

145
UTO Series | Technical Information

Assembly Instructions (Continued)



UTO0 or UTO7 with UTO6 + JCS or JC or JCSL or JCL for Unshielded Cable

Cable gland body


UTO0 Adapter Backshell nut

Ferrule
UTO6

UTO7

• Slide accessories onto the cable gland body to adapter and tighten (recommended torque:
• Strip external cable jacket (see dimension H in the table below) see table below)
• Strip wires and crimp contacts (see pages 140 & 141) • Mate the plug with the receptacle to make the following step easier
• Insert contacts into connector cavities (insert manually or use tool • Slide ferrule inside the cable gland body as shown in fig. A
RTM205) • Tighten backshell nut with cable gland body as shown in fig. B
• Screw adapter to the rear of the connector body and screw cable (recommended torque: see below).

fig. A fig. B

Adapter Cable gland body Backshell nut H min. (mm)


Shell size tightening torque tightening torque tightening torque* JCS/JCSL JC/JCL
(Nm) (Nm) (Nm) Male Female Male Female
10 6 6 5 21 29 32 39
12 10 10 8 21 29 31 39
14 10 10 8 25 33 39 47
16 14 14 12 32 40 43 51
18 14 14 12 37 45 47 55
20 24 24 20 39 47 49 57
22 24 24 20 41 50 53 61
24 24 24 20 47 55 57 65
* Indicative torque, needs to be adjusted depending on the cable used

Spanner size
JCS/JC JSCL/JCL
Shell size
Cable gland body Backshell nut Cable gland body Backshell nut
10 17 mm 14 mm 17 mm 17 mm
12 & 14 22 mm 20 mm 22 mm 22 mm
16 & 18 26 mm 24 mm 30 mm 30 mm
20, 22 & 24 33 mm 30 mm 40 mm 40 mm

146
UTO Series | Technical Information


UTO0 or UTO7 with UTO6 + JCS or JC or JCSL or JCL for Shielded Cable

Adapter Cable gland body


UTO0 Backshell nut L

Shielding ferrule
UTO6

UTO7

• Slide accessories onto the cable gland body to adapter and tighten (recommended torque:
• Strip external cable jacket (see dimension H and L in the table below) see table below)
• Strip wires and crimp contacts (see pages 140 & 141) • Mate the plug with the receptacle to make the following step easier
• Insert contacts into connector cavities (insert manually or use tool • Slide ferrule inside the cable gland body as shown in fig. A
RTM205) • Tighten backshell nut with cable gland body as shown in fig. B
• Screw adapter to the rear of the connector body and screw cable (recommended torque: see below).

fig. A fig. B

Adapter Cable gland body Backshell nut H min. (mm)


L min.
Shell size tightening torque tightening torque tightening torque JCS/JCSL JC/JCL
(inch)

Technical Information
(Nm) (Nm) (Nm) Male Female Male Female
10 6 6 5 50 58 61 68 8
12 10 10 8 54 61 65 73 12
14 10 10 8 59 66 73 80 12
16 14 14 12 68 75 79 86 12
18 14 14 12 72 80 83 91 12
20 24 24 20 80 89 90 98 14
22 24 24 20 83 91 94 102 14
24 24 24 20 88 96 98 106 14
* Indicative torque, needs to be adjusted depending on the cable used

Spanner size
JCS/JC JSCL/JCL
Shell size
Cable gland body Backshell nut Cable gland body Backshell nut
10 17 mm 14 mm 17 mm 17 mm
12 & 14 22 mm 20 mm 22 mm 22 mm
16 & 18 26 mm 24 mm 30 mm 30 mm
20, 22 & 24 33 mm 30 mm 40 mm 40 mm

147
UTO Series | Technical Information

Assembly Instructions (Continued)

UTO0 or UTO7 with UTO6 + AC Backshell Assembly

UTO0

Modular
gasket

Cable clamp

UTO6

UTO7

• Slide accessories onto the cable • Tighten backshell with plug and mate plug with a receptacle
• Strip external cable jacket (recommended torque values to be applied according to the
• Strip wires and crimp contacts (see pages 140 & 141) table below)
• Insert contacts into connector cavities (insert manually or use tool • Tighten backshell screws.
RTM205)

Clamp (mm)
Shell size Cable clamp tightening torque (Nm)
Min Max
10 4 1.5 5.0
12 5 3.0 8.2
14 5 4.0 10.0
16 9 6.0 13.0
18 9 8.5 16.0
20 11 10.0 16.0
22 13 9.0 19.3
24 15 11.0 20.6

148
UTO Series | Technical Information

UTO0 or UTO7 with UTO6 + LPGN Backshell Assembly

UTO0

Right angle
cable clamp

UTO6

UTO7

• Remove inner part of the modular gasket to adjust the internal • Tighten backshell with plug and mate plug with a receptacle
diameter to fit the cable (see table) (recommended torque values to be applied according to the
• Slide accessories onto the cable table below)
• Strip external cable jacket • Tighten backshell screws.
• Strip wires and crimp contacts (see pages 140 & 141)

Ø Cable range (mm)


Shell size Right angle cable clamp tightening torque (Nm)
A B C D
10 6 5 7.5 10 -
12 10 7.5 10 13 -

Technical Information
14 10 7.5 10 13 -
16 14 7.5 11 13.5 16
18 14 10 13.5 17 20
20 24 10 13.5 17 20
22 24 10 13.5 17 20
24 24 18 22 25.5 29

Ø Cable range

A
B
C
D

149
UTO Series | Technical Information

Assembly Instructions (Continued)



UTO0 or UTO7 with UTO6 + JCPGN Backshell Assembly

Outer shielding PG- nut L


UTO0 Washers
ferrule

UTO6 Modular
PG-tube gasket
Inner shielding adapter
ferrule
UTO7

• Mate UTO6 (plug) with UTO0 or UTO7 already mounted on a • Place cable braid shield over inner shielding ferrule (See fig. A)
panel and slide the outer ferrule over the braid shield for UTOS-JCPGN
• Slide accessories onto the cable • Screw PG-tube adapter with plug (recommended torque:
• Strip external cable jacket (see dimension H and L) see below table)
• Strip wires and crimp contacts (see pages 140 & 141) • Tighten PG-nut with PG-tube adapter (See fig. B)
• Insert contacts into connector cavities (insert manually or use • Tighten PG-nut screws.
RTM205 tool)

UTOS-JCPGN

fig. A fig. B

PG-tube PG-nut Ø Cable range (mm) H min. (mm) L min.


Shell size
tightening torque (Nm) tightening torque (Nm) UTO UTOS Pin contacts Socket contacts (mm)

10 4 1.5 4 to 10 4 to 8.8 26.5 34.2 17.6


12 6 1.5 4 to 11.9 4 to 11.9 26.5 34.2 17.6
14 10 3.5 6.5 to 13.5 6.5 to 13.5 29.6 37.2 20.6
16 10 6.5 6.5 to 16 6.5 to 16 31.6 39.2 22.6
18 10 6.5 6.5 to 16 6.5 to 16 36.9 42.3 26.7
20 15 9 9 to 21 9 to 21 36.4 41.8 26.1
22 15 9 9 to 21 9 to 21 43.4 48.8 33.2
24 15 12 17 to 29.5 17 to 29.5 43.8 49.2 33.6
Ø individual braid shield conductor betweenn 0.3 and 0.5mm
Torques to be applied with the plug mated with the receptacle.

150
UTO Series | Technical Information

UTO6 or UTO7 with GN Backshell Assembly

UTO6

Nut

Grommet +
compression ring

UTO7

• Strip wires and crimp contacts (see pages 140 & 141) • Insert the other contacts
• Insert first contact into the grommet (first contact in cavity A, • Tighten the nut to rear of either UTO7 or UTO6 (recommended
no tool is required). Then insert the contact in the connector torque values to be applied according to the table below).
cavity A (insert manually or use tool RTM205)

Shell size layout Nut tightening torque (Nm) Ø Wire


10 4 1
From
12 8 1.5 1.7 mm
14 7 1.5 to
3.0 mm
14 12 1.5

Technical Information

151
UTO Series | Technical Information

Assembly Instructions (Continued)

UTO6 or UTO7 with GJC Backshell Assembly

Nut
UTO6
Adapter + mounted gasket

Cable range

Grommet +
compression ring

Reducing Standard

UTO7
Cable ranges

• Strip wires and crimp contacts (see pages 140 & 141) • Tighten adapter with plug, choose right seal (waste the other
• Insert first contact into the grommet (first contact in cavity A, seal)
no tool is required). Then insert the contact in the connector • Tighten the nut to rear of either UTO7 or UTO6 (recommended
cavity A (insert manually or use tool RTM205) torque values to be applied according to the table below).
• Insert the other contacts

Recommended jacket Ø Cable range Ø Cable range


Shell strip length (mm) Adapter tightening Nut tightening
Layout Standard seal Reducing seal Ø Wire
size torque (Nm) torque (Nm)
Male Female (mm) (mm)
10 4 21 29 1.5 1 2.5/8.0 1.5/5.0
From
12 8 25 33 2 2.5 5.0/12.0 3.0/9.0 1.7 mm
14 7 29 36 3 2.5 7.0/14.0 5.0/12.0 to
3.0 mm
14 12 29 36 3 2.5 7.0/14.0 5.0/12.0

152
UTO Series | Technical Information

Mated Connector Length with Backshell


UTO0 + UTO6 + AC UTO0 + UTO6GN
A C

B D

UTO7 + UTO6 + AC UTO7 + UTO6GN

UTO0 + UTO6 UTO7+ UTO6


Shell size + AC backshell + GN backshell + AC backshell + GN backshell
A max (mm) C max (mm) B max (mm) D max (mm)
10 53.5 39.1 58.3 43.9
12 53.5 38.9 58.3 43.7
14 52.0 39.4 56.8 44.2
16 55.5 - 60.3 -
18 56.5 - 61.3 -
20 58.5 - 64.0 -
22 57.0 - 62.5 -
24 59.0 - 64.5 -

Backshell without shielding Backshell with shielding


UTO0 + UTO6 + UTO with UTO0 + UTO6 + UTOS with
JCS or JC or JCSL or JCL JCS or JC or JCSL or JCL
E H

Technical Information
F L
UTO7 + UTO6 + UTO with UTO7 + UTO6 + UTOS with
JCS or JC or JCSL or JCL JCS or JC or JCSL or JCL

UTO0 + UTO6 + UTO with UTO7+ UTO6 + UTO with UTO0 + UTO6 + UTOS with UTO7+ UTO6 + UTOS with
Shell size JCS JC JCSL JCL JCS JC JCSL JCL JCS JC JCSL JCL JCS JC JCSL JCL
E max E max E max E max F max F max F max F max H max H max H max H max L max L max L max L max
10 68.1 80.1 68.1 80.1 72.8 84.8 72.8 84.8 78.1 90.1 79.1 91.1 82.8 94.8 83.8 95.8
12 68.1 81.1 69.1 82.1 72.8 85.8 73.8 86.8 81.1 94.1 81.1 94.1 85.8 98.8 85.8 98.8
14 73.1 87.1 74.1 88.1 77.8 91.8 78.8 92.8 86.1 100.1 86.1 100.1 90.8 104.8 90.8 104.5
16 82.1 93.1 88.1 99.1 86.8 97.8 92.8 103.8 92.1 103.1 102.1 113.1 96.8 107.8 106.8 117.8
18 85.1 95.6 91.1 101.6 89.8 100.3 95.8 106.3 95.1 105.6 105.1 115.6 99.8 110.3 109.8 120.3
20 98.4 108.2 105.4 115.2 103.9 113.7 110.9 120.7 111.9 121.7 120.9 130.7 117.4 127.2 126.4 136.2
22 100.7 112.0 107.7 119.0 106.2 117.5 113.2 124.5 114.2 125.5 123.2 134.5 119.7 131.0 128.7 140.0
24 106.9 116.9 113.9 123.9 112.4 122.4 119.4 129.4 120.4 130.4 129.4 139.4 125.9 135.9 134.9 144.9
Note: all dimensions are in mm

153
UTO Series | Technical Information

Mated Connector Length with Backshell (Continued)


UTO0 + UTO6 + JCPGN
M

UTO7 + UTO6 + JCPGN

UTO0 + UTO6 + JCPGN UTO7+ UTO6 + JCPGN


Shell size
M max (mm) N max (mm)
10 82.4 87.1
12 84.6 89.3
14 89.6 94.3
16 95.0 99.7
18 99.1 103.8
20 111.1 116.6
22 118.2 123.7
24 132.9 138.5
Note: all dimensions are in mm

154
UTO Series | Technical Information

Rated Current & Working Voltage

Current Carrying Capacity

The current carrying capacity of a connector is limited by the thermal properties of materials used in its construction. The amount of current that
can be handled depends on the size of cable used, the ambient temperature and the heat that is generated inside the connector. Part 3 of the
IEC 60512 standard determines through a derating curve, the maximum current permissible, which varies from one layout to another (Fig.1 &
Fig.2). Wire size plays an important role in dissipating heat and avoid overheating (Fig.1 & Fig.3).

Please note that the curve should be adjusted when dealing with potential hot spots, which can occur as a result of unequal loading of current
across a number of contacts. As a general rule, it is best to avoid placing power handling contacts in the middle of the connector; try to locate
them towards the edge where heat can be dissipated more effectively. Eventually you should find a level which represents the permissible ope-
rating range:

Fig.1: UTO 12-4 – 1.5mm² wires Fig.2: UTO 12-8 – 1.5mm² wires
30 30
28 28
25 25
23 23
Current (A)

20 20
Current (A)

18 18
15 15
13 13
10 10
8 8
5 5
3 3
0 0
0 20 40 60 80 100 120 0 20 40 60 80 100 120
Ambient Operating Temperature (°C) Ambient Operating Temperature (°C)

Fig.3: UTO 12-4 – 2.5mm² wires


35
33
30
28
25
23 Current use
Current (A)

20

Technical Information
18
15
Limited use
13
10 Not recommended use
8
5
3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)

The rated current is defined as uninterrupted continuous current that a connector can take when all contacts are energized simultaneously
without exceeding the maximum limit of temperature. The earth contact is never loaded.

155
UTO Series | Technical Information

Shielding Effectiveness/Corrosion

Shielding Effectiveness

EMC (Electro-Magnetic Compatibility) means a device (e.g.


a connector) can tolerate interferences and continue to work
properly.
It's generally measured via the shielding effectiveness.
This value is a ratio between the power radiated inside to the
maximum power interferences outside.

(dB)=10Log Pin
Pout
Pin: Power in
Pout: Power out

Corrosion Resistance

Control of corrosion impact on electronic devices is an


important expertise. Metal connectors suitable for outdoor
and indoor use should be able to withstand climate ingress,
Tempory outdoor exposure

with corrosive atmospheres


exposure to salt spray and corrosive gases while still
Outdoor application

Outdoor application
maintaining mechanical and electrical functionality.

4 Corrosive Gases)
Indoor application

(Salt Spray and


Over the years, many different test methods have been
developed but never really captured the exact equivalence
between testing scenarios and real electronic device
exposure to corrosive environments. Souriau has been
developing, manufacturing and testing connector solutions
for more than 90 years and has developed a unique corrosion
test based on Salt Spray exposure combined with four
additional corrosive gases. Typical industrial applications
may involve exposure to corrosive atmospheres equivalent
to 48 or 96 hours. Souriau’s UTO product series has been
validated to withstand corrosive agent exposure at these
timeframes. In addition, we can offer different solutions
and plating options to withstand longer corrosion exposure 0 48 Hrs 96 Hrs 500 Hrs
times and test up to 500 hours.

156
UTO Series | Technical Information

UL94 + UL1977

Underwriter Laboratories

There are two main standards for industrial connectors: UL94 & UL1977

UL94
This standard is dedicated to plastics flammability. It characterises how the material burns in various orientation and thicknesses.

The UTO series has been rated at V-0 & HB.

Procedure: A specimen is supported in a vertical or horizontal position and a flame is applied to the bottom of the specimen. The flame is applied
for ten seconds and then removed until flaming stops, at which time the flame is reapplied for another ten seconds and then removed. Two sets
of five specimens are tested.

13±0.5mm

V-0 Vertical burning:


• Specimens must not burn with flaming combustion for more
than 10 seconds after each test flame application

Material
• Total flaming combustion time must not exceed 50 seconds
for each set of 5 specimens 125±1mm
• Specimens must not burn with flaming or glowing combustion
up to the specimen holding clamp
• Specimens must not drip flaming particles that ignite
the cotton
• No specimen can have glowing combustion remain for longer
than 30 seconds after removal of the test flame.

45°

300±1mm
~
~
Cotton

100±1mm Technical Information


HB Horizontal burning:
25±1mm
• A material classified HB shall not have a burning rate
exceeding 40 mm per minute over a 75 mm span for 13±0.5mm Material
specimens having a thickness of 3.0 to 13 mm 45°
• A material classified HB shall not have a burning rate
exceeding 75 mm per minute over a 75 mm span for
specimens having a thickness less than 3.0 mm 10±1mm
• A material classified HB shall cease to burn before the Wire gauze 45°
100 mm reference mark.
Wire gauze

157
UTO Series | Technical Information

UL94 + UL1977 (Continued)

Underwriter Laboratories

UL1977
There are several standards which deal with plug and receptacle. Each of them is only for a small area of applications. It could be
telecommunication, etc. The UL 1977 covers single and multipole connectors intended for factory assembly.

Requirements apply to devices taking into account intensity and voltage. The categories are as follows:

30 V
0 (42 V peak) 600 V

Type 0 Type 1A

8.3 A

Type 2

31 A Tybe 1B

Type 3

200 A

Type 4

1000 A
According to above table, the level of performance that has to be reached could be different. Most of them are explained in the following page.

Insulating materials:
Material uses for electrical insulation, as a minimum, have to comply with the characteristics shown below:

• Minimum ratings for polymeric materials

Relative thermal index (RTI)


Type Flame rating
Electrical/mechanical w/o impact */**
0 - 50/50
* The RTI of the material shall not be lower than the temperature measured during
1A HB 50/50 the Temperature Test.
** For a thickness less than that for which a value has been established, the RTI of
1B HB 50/50 the minimum thickness with an established value shall be used.
2 HB 50/50
3 HB 50/50
4 HB 50/50

Assembly:
Connector has to be keyed to prevent any mismating that can damage the machine or hurt the user. In the same way, plugs and sockets have to
be equipped to protect persons against contact with live parts.
Finally the identified grounding contact shall be located so that the corresponding electrical continuity has to be completed before any other
contact.

158
UTO Series | Technical Information

Underwriter Laboratories

UL1977
Spacing:
For a 250V max connector, distance through air or over material shall be 1.2mm whereas from 250V to 600V connector the spacing is 3.2mm
minimum. These distances have to be taken between uninsulated live parts as shown in the matrix below:

• Applicability of spacing requirements

Uninsulated live part - uninsulated Uninsulated live part - uninsulated Uninsulated live part - exposed dead
Type
live part of opposite polarity grounded metal part metal part
0 No No No
1A Yes Yes Yes
1B Yes Yes No
2 Yes Yes Yes
3 Yes Yes Yes
4 Yes Yes Yes

An alternative way to determine voltage rating is with the Dielectric-Withstand test. If during one minute there is no arc-over or breakdown the
rated voltage is given as shown below:

a) 500 volts for a type 1B device


b) 1000 volts plus twice rated voltage for types 1A, 2, 3 and 4 devices.

Marking:
A device shall be legibly marked with the manufacturer's trade name, trade mark, or other descriptive marking by which the organisation
responsible for the product may be identified. (Exception: If the device is too small, or where the legibility would be difficult to attain, the
manufacturer’s name, trademark, or other descriptive marking may appear on the smallest unit container or carton)

The following shall be marked on the device or on the smallest unit container or carton or on a stuffer sheet in the smallest unit container or
carton:

a) The catalog number or an equivalent designation

Technical Information
b) The electrical rating in both volts and amperes, if assigned
c) Whether ac or dc, if restricted
d) Flammability class, if identified

Example - Marking for the arrangement 10-3: 10A 500V UL94 V-0

159
UTO Series | Technical Information

IEC 61984 & IP Codes Explained

IEC 61984

The norm is dedicated to connectors with rated voltage above 50V and up to 1000V and rated currents up to 125A per contact.
Depending on your application connectors should be compliant with another standard. This has to be double checked with the customer.

There are a lot of constructional requirements and performances specified in that standard. Most of them are illustrated in greater details hereafter.

Provisions for earthing:


The UTO connector is intended to be used on Class I or Class III (see IEC 61140) systems. Even if the purpose of our connector is not to interrupt
current, there is a need to add a protective earth contact. This one shall be a “First mate, last break” style. Critically, among all of the normal
assumptions we make in designing a connector, this contact has to be considered as a live part and must be protected attached to the ground
wire.

First digit
IP Code: (foreign bodies
IP is a coding system defined by the IEC 60529 to indicate the protection)
degrees of protection provided by an enclosure. The aim of this is to
give information regarding the accessibility of live parts against ingress
of water and other foreign bodies. Code letters Second digit
(international IP 6 8 (water
Protection) protection)

1st digit Degree of protection 2nd digit Degree of protection


0 No protection against accidental contact. 0 No protection against water.
No protection against solid foreign bodies.
1 Protection against contact with any large area by hand and against 1 Drip-proof.
large solid foreign bodies with a diameter bigger than 50 mm. Protection against vertical water drips.
2 Protection against contact with the fingers. 2 Drip-proof.
Protection against solid foreign bodies with a diameter bigger than Protection against water drips up to a 15° angle.
12 mm.
3 Protection against tools, wires or similar objects with a diameter 3 Spray-proof.
bigger than 2.5 mm. Protection against diagonal water drips up to a 60° angle.
Protection against small solid bodies with a diameter bigger than
2.5 mm.
4 Same as 3 however diameter is bigger than 1 mm. 4 Splash-proof.
Protection against splashed water from all directions.
5 Full protection against contact. Protection against interior injurious 5 Hose-proof.
dust deposits. Protection against water (out of a nozzle) from all directions.
6 Total protection against contact. 6 Protection against temporary flooding.
Protection against penetration of dust.
7 Protection against temporary immersions.
UTO offers high sealing 8 Protection against water pressure.
performance IP68 / 69K… Pressure to be specified by supplier.
Even in dynamic situations.
In addition to the IEC 60529 we conjointly use the DIN 40050 part 9
which are dedicated to road vehicles. The main differences are:
• First digit: 5 replaced by 5K, 6 by 6K. In the DIN the tested
equipment is not depressurized as it is in the IEC.
• Second digit: 5K and 6K has been added and are equivalent
respectively to 5 and 6 but with higher pressure.
9K which represents the High pressure cleaning.

9K High pressure hose-proof.


Protection against high pressure water (out of a nozzle) from all
directions.

IEC 61984 ed.2.0 “Copyright © 2008 IEC Geneva, Switzerland.www.iec.ch"


IEC 60664-1 ed.2.0 “Copyright © 2007 IEC Geneva, Switzerland.www.iec.ch”

160
UTO Series | Technical Information

IEC 61984

Overvoltage
UTO connectors are qualified to be used on systems rated at Overvoltage category III

Per the IEC 60664-1 (formely VDE 0110) each category is linked to the end application and where the device will be implemented:

• Category IV (primary overcurrent protection equipment):


Origin of the installation

• Category III (any fixed installation with a permanent connection)


Fixed installation and equipment and for cases where the reliability and the availability is subject to special requirements

• Category II (domestic appliances):


Energy consuming equipment to be supplied from the fixed installation

• Category I (protected electronic circuit):


For connection to circuit in which measures are taken to limit transient overvoltage.

Pollution degree
Per the IEC 60664-1 (formerly VDE 0110) the environment affects the performance of the insulation. Particles can build a bridge between
two metal parts. As a rule dust mixed with water can be conductive and more generally speaking metal dust is conductive. Finally, the
standard defines 4 levels of pollution:

• Degree 1 (Air conditioned dry room):


No pollution or only dry, non conductive pollution occurs. The pollution has no influence.

• Degree 2 (Personal computer in a residential area):


Only non conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is to be
expected.

• Degree 3 (Machine tools):


Conductive pollution occurs or dry non-conductive pollution occurs which becomes conductive due to condensation which is to
be expected.

• Degree 4 (Equipments on roof, locomotives):


Continuous conductivity occurs due to conductive dust, rain or other wet conditions.

Technical Information
Finally, the harsher the environment is, the longer clearance and creepage distances should be. Nonetheless, according the IEC 61984,
enclosure rated at IP54 or higher can be dimensioned for a lower pollution degree. This applies to mated connectors disengaged for test and
maintenance.

Marking
The marking should give enough details to the user to know what the main characteristics are and without going deep in technical
documentation. Below examples identify the suitability of the connector:

• Example 1:
Marking of a connector with rated current 16A, rated voltage 400V, rated impulse voltage 6kV and pollution degree 3, 2 and 1 for
use in any system, preferably unearthed or delta-earthed systems:

16A
16A 400V
400V 6kV
6kV 33

• Example 2:
Marking of a connector with rated current 16A, rated insulation voltages line-to-earth 250V, line-to-line 400V, rated impulse
voltage 4kV and pollution degree 3, 2 and 1 for use in earthed systems:

16A250V
16A 250V400V
400V4kV
4kV3 3

161
UTO Series | Technical Information

IEC 61140 Explained

IEC 61140

On a daily basis, we are using many electrical appliances, some are grounded, and some are not. The levels of grounding protection are clearly
defined by the International Electrotechnical Commission standard IEC 61140, a standard that has an influence on our connectors and how
they should be used; our customers therefore need to pay particular attention to the three categories defined within this standard to ensure
compatibility with their system. Everything explained hereafter is valid for connectors not intended to interrupt current.

Class I:
Devices which belong to this category have their chassis grounded via the ground wire (green/yellow in Europe, green in the US, Canada and
Japan). A fault in the appliance might cause a live conductor to energize the casing. In this case, the current flows to the ground conductor and
the circuit interrupter will cut off the power supply. In case of the UTO series, it means the envelope (coupling ring, backshell and housing) may
become live, therefore, care needs to be taken to attach the connector to the ground. This is usually done via the ground conductor using a splice
between the ground contact and the housing.

Class II:
Products in this category have reinforced insulation, meaning that the casing does not need to be connected to ground. In this case, the possibility
of electric shock has been removed. Most of the time, reinforced insulation means double insulation, i.e. the second layer will take over the first
one in case the first one fails. The UTO series is not designed to comply with this standard, so we cannot recommend it for this product category.

Note: UL 1310 also defines a class II device, but in that case this is just to set the upper limit of use, like a wall charger for our cell phone.

Class III:
In this category, electrical appliances are fed by a low voltage source (<48VAC or < 120VDC). In normal conditions live conductors can be
accessible without any risk for the end user. No particular attention needs to be taken in regards to UTO series when it comes to a class III device.

Conclusion :
UTO series can be used in class I and class III environments, but each category affects the product performance. Throughout the catalog, current
and voltage ratings have been given for class I devices keeping in mind the ground conductor needs to be attached according to recommended
wiring instructions.

Note: Special applications like recreational vehicles are not under the scope of the IEC 61140.

162
UTO Series | Technical Information

What is NEMA Rating ?


• NEMA ratings vs IP ratings
Whereas IP ratings only consider protection against ingress of foreign bodies (first digit) and ingress of water (second digit), NEMA ratings consider
these but also verify protection from external ice, corrosive materials, oil immersion, etc.

The correlation between NEMA & IP being limited only to dust and water, we can state that a NEMA type is equivalent to an IP rating but it is not
possible to say the contrary.

Below a list of some NEMA standards:

Enclosure
IP20 IP22 IP55 IP64 IP65 IP66 IP67 IP68
rating
Type 1 •
Type 3 •
Type 3R •
Type 3S •
Type 4 •
Type 4X •
Type 6 •
Type 6P •
Type 12 •
Type 13 •
• indicates compliance

Type 6 rating can be either Type 6 or Type 6P - please see below:

6 IP67 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with the enclosed equipment, falling dirt, hose-directed water, the entry of water during occasional temporary
submersion at a limited depth and damage from external ice formation.

6P IP68 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with the enclosed equipment, falling dirt, hose-directed water, the entry of water during prolonged submersion at

Technical Information
a limited depth and damage from external ice formation.

163
UTO Series | Technical Information

Ethernet for the Layman


In order to explain basic Ethernet theory, we can use a functional comparison to a busy city with highways, buildings and cars. To illustrate this, the
table below provides correlation between the different components/pieces/links that encompass Ethernet network connectivity, and the larger scale
infrastructure of a metropolitan city.

• City: The network itself


• Buildings: End equipment, PC, server, etc.
• Roads: Ethernet cabling
• Cars: Data packets, datagrams, bits, bytes, etc.
• Tolls: Firewalls
• Bridges: Connectors
• Traffic laws: Protocol/communication specifications

Ethernet Basics
Ethernet is a widely used communications protocol that is used to transmit data packets (datagrams) between network devices. Imagine a highway in a
large metropolitan area six lanes wide at rush hour. The vehicles on the highway need rules to follow so that they get to their destination without crashing
into each other. In an Ethernet network link, there could be 100 million bits of information transmitted in one second. In the Ethernet standard, there exist
rules to govern packet structure, transmission requirements, error correction, communication with end equipment, etc.

Examining the differences between 100Mhz, 100 Base TX, Cat5e/Cat6.


What does it all mean?
When discussing connectors and Ethernet, there are a few key details to be aware of:
• 100Mhz is a measurement of Frequency for the signal
- Comparable to the Speed Limit of a highway
• 100BaseTX (or Fast Ethernet) is an Ethernet link standard and identifies available link bandwidth. The bandwidth is measured in units of
MBits/S (megabits per second)
- Comparable to the number of cars that pass a point in one second
• Cat5e/Cat6 are an EIA/TIA standard for performance and physical characteristics for cables and connectors
- Comparable to performance specifications of the car and highway.

In connectors and cables, Fast Ethernet uses 2 pairs. One for transmit and one for receive. This way data traffic can flow in both directions simultaneously.

164
UTO Series | Technical Information

Souriau offering:
Standard solutions.

UTO size 10, 6 contacts - Cat5e UTO size 12, 10 contacts - Cat5e UTO size 16, 19 contacts -Cat5e
Twisted pairs Twisted pairs Twisted pairs (1Gb/s)

1 (Pair 1) Ã A 1 (Pair 1) Ã C 1 (Pair 1) Ã A


2 (Pair 1) Ã B 2 (Pair 1) Ã B 2 (Pair 1) Ã B
3 (Pair 2) Ã E 3 (Pair 2) Ã G 3 (Pair 2) Ã D
4 (Pair 2) Ã D 4 (Pair 2) Ã H 4 (Pair 2) Ã E
106 5 (Pair 3) Ã G
6 Ø 1 (#20) 1210 6 (Pair 3) Ã H
10 Ø 1 (#20) 7 (Pair 4) Ã K
Shielding continuity done in cavity C&F. 8 (Pair 4) Ã L 1619
Note: Shielding can be replaced by Cat6 if shielding continuity done by other
DC power. contact 19 Ø 1.6 (#16)

UTO size 10, 4 contacts - Cat6


Quad cable

1 (Pair 1) Ã A
2 (Pair 1) Ã B

104
4 Ø 1.6 (#16)

What about using coax contacts ?


Ethernet twisted pairs carry a symmetrical (balanced) signal. Once terminated into a coax contact, the inner core will be protected by a shield - but not
the outer contact. Because of EMI issues, the signal will no longer be balanced. Conclusion - it does not work and is not recommended.

What about using Quadrax contacts ?


The Quadrax contact is used in railway applications because of the use of quad cable. In this specific market, the standard Ethernet twisted pairs wires

Technical Information
cannot be offered, they are too thin and often solid (not stranded).

In the rest of industry, UTP (Unshielded Twisted Pairs) cables are widely used. The Quadrax contact is not designed to terminate them. And thus, are not
advised for industrial applications.

Conclusion
To carry 100Mb/s data signal, 100BaseTX or Fast Ethernet recommends the use of Cat5e connectors as well as Cat5e cable with the support of a 100MHz
signal. Nevertheless, a 100Mb/s signal can be transmitted in certain conditions (short distance, only one connector, lower frequency but a different code)
thru many other connection materials - not necessarily Cat5e rated.

165
UTO SERIES

© 2013 SOURIAU - SOURIAU is a registered trademark


UTO Series

Appendices
#16 Coaxial Contacts/Cabling Notices ................................................................... 168

Glossary of Terms .................................................................................................... 175

Drilling Pattern ........................................................................................................ 176

Discrimination/Keying Methods .............................................................................. 180

Part Number Index .................................................................................................. 181

167
UTO Series | Appendices

#16 Coaxial Contacts

Coaxial Cable - Contact Monocrimp and Multipiece

Inner
Ø over Ø over
cond Ø outer braid
jacket dielectric
Cable Impe- Contact size Male contact kit Female contact kit
type dance type Ext. for coaxial cable for coaxial cable
inch mm inch mm Ø inch mm
mm
RG161/U 75 0.09" 2.29 0.057" 1.45 - - -
RG179A/U 75 0.105" 2.67 0.063" 1.6 0.3 0.084" 2.13 max
RG179B/U 75 0.105" 2.67 0.063" 1.6 0.3 0.084" 2.13 max
RG187/U 75 0.11" 2.79 max 0.06" 1.52 0.3
Multi
RG188/U 50
piece
0.11" 2.79 max 0.06" 1.52 0.51 0.078" 1.98 max RMDXK10D28 RCDXK1D28
RG174/U 50 0.11" 2.92 0.06" 1.52 0.48 0.088" 2.24 max
AMPHENOL 21-598 50 0.105" 2.67 0.06" 1.52 0.48 - -
RG196/U 50 0.08" 2.03 max 0.034" 0.086 0.3 - --
RG178A/U 50 0.075" 1.91 0.034" 0.86 0.3 0.054" 1.37 max
RG/188A/U 50 0.110" 2.79 0.06" 1.52 0.51 0.078" 1.98 max RMDX6036D28 RCDX6036D28
KX21TVT (europe)
RG178 B/U
50 0.075" 1.91 0.034" 0.86 0.3 0.054" 1.37 max RMDX6034D28 RCDX6034D28

RG178 / BU 50 0.075" 1.91 0.034" 0.86 0.3 0.054" 1.37 max RMDX6050D28 RCDX6016D28
RG174/U 50 Mono 0.115" 2.92 0.06" 1.52 0.48 0.088" 2.24 max RMDX6032D28 RCDX6032D28
crimp
RG188A/U 50 0.11" 2.79 0.06" 1.52 0.51 0.078" 1.98 max RMDX6036D28 RCDX6036D28
RG316/U 50 0.107" 2.72 0.06" 1.52 0.51 0.078" 2.05 max RMDX6036D28 RCDX6036D28
raychem 5024A3111 50 0.12" 3.05 0.083" 2.11 0.64 0.097" 2.46 RMDX6052D28 RCDX6052D28
raychem 5026e1614 50 0.083" 2.11 0.05" 1.27 0.48 0.067" 1.7 RMDX6036D28 RCDX6036D28
Multi
surprenant pn 8134 -
piece
0.1" 2.54 0.058" 1.47 0.3 - - RMDXK10D28 RCDXK1D28
PRD PN 247AS-
C1123-001
- 0.103" 2.62 0.06" 1.52 0.51 0.078" 1.98 RMDX6018D28 RCDX6018D28

PRD PN 247AS-C1251 - 0.092" 2.34 0.05" 1.27 0.64 0.067" 1.7 RMDX6018D28 RCDX6018D28
JUDD C15013010902 - 0.087" 2.13 0.05" 1.27 0.48 0.066" 1.67 RMDX6036D28 RCDX6036D28
CDC PIN22939200 - 0.09" 2.29 0.048" 1.22 0.3 0.064" 1.63 RMDX6046D28 RCDX6016D28
CDC PIN22939200 - 0.09" 2.29 0.048" 1.22 0.3 0.064" 1.63 RMDX6050D28 RCDX6016D28
CDC PIN245670000 - 0.104" 2.64 0.067" 1.7 0.3 0.083" 2.11 RMDX6050D28 RCDX6016D28
ampex - Mono 0.114" 2.9 0.075" 1.91 0.38 0.09" 1.29 RMDX6032D28 RCDX6032D28
TI PN 920580 - crimp 0.7" 1.78 0.038" 0.96 0.48 0.054v 1.37 RMDX6024D28 RCDX6024D28
0.41
Honeywell PN 58000062 - 0.12" 3.05 0.077" 1.96
solid
0.096" 2.44 RMDX6026D28 RCDX6026D28

- - 0.104" 2.64 0.067" 1.7 0.3 - 2.11 RMDX6050D28 -


- - 0.09" 2.29 0.048" 1.22 0.3 - 1.63 RMDX6050D28 -
- - 0.114" 2.9 0.075" 1.91 0.38 - 1.29 RMDX6032D28 RCDX6032D28
- - 0.07" 1.78 0.038" 0.96 0.48 - 1.37 RMDX6024D28 RCDX6024D28
- - 0.12" 3.05 0.077" 1.96 0.41 - 2.44 RMDX6026D28 RCDX6026D28

168
UTO Series | Appendices

Twisted Cable - Contact Monocrimp and Multipiece

Ø over
Ø outer
jacket Inner cond size
Inner braid Male Female
Cable Contact (single wire)
AWG contact kit for contact kit for
type type
cond coaxial cable coaxial cable
Stranded Ext. Ø
inch mm inch mm
definition mm

1.24
2#24 stranded mil-w-16878 type B 24 0.049"
max
7/.008 - - RMDXK10D28 RCDXK1D28

1.12
2 #24 solid mil-w-76 type LW 24 0.047"
max
1/.0201 - - RMDXK10D28 RCDXK1D28

2 #26 stranded mil-w-76 type LW 1.09


or mil-w-16878 type b&e
26 0.043"
max
7/.0063 0.16 - - RMDXK10D28 RCDXK1D28
Multi
piece 0.71
2 #28 solid mil-w-81822/3 28 0.028"
max
- - RMDXK10D28 RCDXK1D28

Twisted pair 1/.201 solid mil-w-76 1.12


type LW or mil-w-16878
26 0.044"
max
1/.0201 0.511 - - RMDXK10D28 RCDXK1D28

0.71
Twisted pair solid mil-w-81822/3 28 0.028"
max
1/.0126 0.32 - - RMDXK10D28 RCDXK1D28

#28 7/.0036 per Hitachi spec RMDX6031D28 + RCDX6031D28 +


- 0.046" 1.17 7/.0036 - - -
ec-711 (13-2820) YORX090 YORX090
RMDX6031D28 + RCDX6031D28 +
20218201 - 0.028" 0.71 - - - -
YORX090 YORX090
RMDX6015D28 + RCDX6015D28 +
#30 solid - 0.025" 0.64 - - - -
YORX090 YORX090
RMDX6031D28 + RCDX6031D28 +
#26 7/.0063 26 0.028" 0.71 7/.063 0.16 - -
YORX090 YORX090
RMDX6019D28 + RCDX6019D28 +
#26 19/.004 26 0.049" 1.24 19/.004 - - -
YORX090 YORX090
Mono RMDX6019D28 + RCDX6019D28 +
#24 7/.008 24 0.049" 1.24 7/.008 - - -
crimp YORX090 YORX090
RMDX6019D28 + RCDX6019D28 +
#24 19/.005 24 0.057" 1.45 19/.005 - - -
YORX090 YORX090
RMDX6019D28 + RCDX6019D28 +
- 26 - 1.25 - - - 19x0.1
YORX090 YORX090
RMDX6019D28 + RCDX6019D28 +
- 24 - 1.25 - - - 7x0.2
YORX090 YORX090
RMDX6019D28 + RCDX6019D28 +
- 24 - 1.45 - - - 19x0.13
YORX090 YORX090
RMDX6031D28 + RCDX6031D28 +
- 26 - 0.7 - - - 7x0.16
YORX090 YORX090
Appendices

169
UTO Series | Appendices

#16 Coaxial Contacts (Continued)

Twisted Pair Cable Multipiece Contact Cabling

Cable strip Inner conduc-


Cable Contact Female Crimp Die Stop Braid crimp
Male contact length tor crimp
reference type contact tool set bushing
A B C g dim t dim g dim t dim
2#24 stranded mil
w 16878 type B
2 #24 solid mil-w-76
type LW
2 #26 stranded
mil w 76 type LW or
mil w16878 type B & E Multi
2 #28 solid piece
RMDXK10D28 RCDXK1D28 M10S1J - - See assembly notice
mil-w-81822/3
twisted pair 1/.201 solid
mil w 76 type LW or mil
w 16878
twisted pair solid mil w
81822/3

Female contact
Strip lengths 6.35±0.41 Outer hyring Twisted pair Inner supporting Outer female contact
sleeve Inner pin
of cable YOC074 adapter
RMD26L-1 RCDX60-2
YORK-090 RCDXB-055-1

7.95±0.41 Conductor "W"

13.49±0.41 Conductor "X"

Step 1: Step 2: Step 3:


Twisted pair adapter

Supporting
Outer hyring sleeve

Male contact
Outer male contact Inner supporting Outer hyring
Inner socket Twisted pair 7.95±0.41
RMDX60-2 sleeve adapter YOC074
RFD26L-1 Strip lengths
RMDXB-055-3 YORK-090 Conductor "Y" of cable

Conductor "Z" 7.95±0.41

15.54±0.41

Step 1: Step 2: Step 3:

Twisted pair adapter


Locking louver typical
7.54

5.94 ±0.41

Inner supporting Grounding louver typical


sleeve Outer hyring
0.25±0.05
7.54±0.41

When using solid wire flatten


conductor "X" and "Z" using 7.95±0.41
N24FL-1 die as shown

15.54±0.41

Note : all dimensions are in mm

170
UTO Series | Appendices

Twisted Pair Cable Monocrimp Contact Cabling

Cable strip Inner conductor


Contact Male Female Crimp Die Stop Braid crimp
Cable reference length crimp
type contact contact tool set bushing
A B C g dim t dim g dim t dim
#28 7/.0036 per Hitachi spec 1.30 to 2.97 to
S80 SL105 4.7 6.1 4.32 1.4 to 1.22 3.07 to 2.9
ec-711 (13-2820) 1.12 2.84
1.30 to 2.97 to 3.07 to
20218204 S80 SL105 3.94 6.1 3.16 1.4 to 1.22
1.17 2.84 2.79
1.22 to 1.35 to 2.97 to 3.12 to
#30 solid S83 SL105 4.7 6.1 4.06
1.12 1.22 2.84 2.95
1.30 to 2.97 to
#26 7/.0063 S80 SL105 4.7 6.1 4.06 1.4 to 1.22 3.07 to 2.9
1.17 2.84

RMDX6031D28 RCDX6031D28 1.22 to 1.35 to 2.84 to 3.12 to


#26 19/.004 Mono 4.7 6.1 4.06
M10S1J 1.17 1.22 2.79 2.97
crimp + YORX090 + YORX090 M10SG8 ASSY'Y
TOOL DIE SET 1.22 to 1.35 to 2.84 to 3.12 to
#24 7/.008 4.7 6.1 4.06
STOP BUSHING 1.17 1.22 2.79 2.97
M10S1J TOOL
1.22 to 1.35 to 2.84 to 3.12 to
#24 19/.005 4.7 6.1 4.06
1.17 1.22 2.79 2.97
AWG26 (19x0.1)
M10SG8
AWG24 (7x0.2)
crimping kit 4.7 6 4
AWG24 (19x0.13)
AWG26 (7x0.16) S80 SL105

• Select appropriate monocrimp coax twisted pair contact and cable combination.
• Select appropriate crimp tooling (hand tool, S-die set, stop bushing).
• Strip the twisted pair cable to the designated wire strip lengths. See cable strip lengths
• Insert the stripped cable into the contact. One cable is to be inserted into the
inside diameter of hyring, and pushed forward into the inner contact. The
second cable is to be inserted between the outside diameter of hyring and the
inside diameter of the outer contact body.
• Crimp the contact.

RMDX60
Cable strip length Male coax contact

B C
RCDX60
Female coax contact

A
16 min.

Braid crimp (G) to be measured with Inner conductor crimp (G) to be


Appendices

die set fully closed measured with die set fully closed

Note : all dimensions are in mm

171
UTO Series | Appendices

#16 Coaxial Contacts (Continued)

Multipiece Male Contact with Coax Cable

Outer contact crimp tool Inner contact crimp tool


Hyring Crimp tool M10S1J Crimp tool M10S1J Cable strip length
Cable
Contact complementary
reference
compoments
Die set Stop bushing Die set Stop bushing
A B C
RG161U 4.37 7.95 15.88
RG179 S23D2 4.37 7.95 15.88
RG187U YOC074 4.37 7.95 15.88
RG188/U 4.37 7.95 15.88
S26D2
RG174/U Male: 4.37 7.95 15.88
RG178A/U YOC074 + S221 SL471 SL46D2 7.54 9.12 17.53
RMDXK10D28 S23D2
RG196U RMDXB0553 7.54 9.12 17.53
AMPHENOL
- 4.37 7.95 15.88
21-598
YOC074
surprenant pn
- 4.37 7.95 15.88
8134

Multipiece kit details Cable strip length

RMDX602D28 Outer contact


RFD26L1D28 Inner contact
RMDXK10D28 A
includes YOC074 Outer hyring Dielectric
diameter B
Inner supporting
RMDXB0553 sleeve C

Contact assembly with dielectric diameter over 1.4mm - without inner supporting sleeve
15.88±0.41
Outer male contact Outer hyring 7.95 ±0.41
Inner socket Strip lengths
RMDX60-2 YOC074
RFD26L-1 4.37±0.41
of cable

Step 1: Step 2: Step 3:


- Assemble outer hyring onto cable - Insert the assembly into the outer male contact - Slide outer hyring forward against spring and
- Assemble inner socket to inner conductor and crimp until the inner socket snaps into place crimp in place as shown
- The cable braid (shield) should now cover the
barrel of the outer male contact as shown Locking louver typical

Grounding louver typical

Contact assembly with dielectric diameter under 1.4mm - with inner supporting sleeve
17.53±0.41
Outer male contact Inner supporting Outer hyring 9.12 ±0.41
Inner socket Strip lengths
RMDX60-2 sleeve YOC074
RFD26L-1 RMDXB-055-3 of cable
7.54±0.41

Step 1: Step 2: Step 3:


- Assemble outer hyring onto cable - Insert the assembly into the outer male contact - Slide outer hyring forward against spring and
- Assemble supporting sleeve over dielectric and under braid until the inner socket snaps into place crimp in place as shown
- Assemble inner socket to inner conductor, push back against - The cable braid (shield) should now cover the
sleeve and crimp barrel of the outer male contact as shown Locking louver typical

Supporting Outer hyring Grounding louver typical


sleeve

Note : all dimensions are in mm

172
UTO Series | Appendices

Multipiece Female Contact with Coax Cable

Outer contact crimp tool Inner contact crimp tool


Hyring Crimp tool M10S1J Crimp tool M10S1J Cable strip length
Cable
Contact complementary
reference
compoments
Die set Stop bushing Die set Stop bushing
A B C
RG161U 4.37 11.13
RG179 S23D2 4.37 11.13
RG187U YOC074 4.37 11.13
RG188/U 4.37 11.13
S26D2
RG174/U Female: 4.37 11.13
RG178A/U YOC074 + S221 SL471 SL46D2 6.35 - 11.13
RCDXK1D28 S23D2
RG196U RMDXB0553 6.35 11.13
AMPHENOL
- 4.37 11.13
21-598
YOC074
surprenant pn
- 4.37 11.13
8134

Multipiece kit details Cable strip length

RCDX602D28 Outer contact


RMD26L1D28 Inner contact
RCDXK1D28 A
includes YOC074 Outer hyring Dielectric
diameter B
Inner supporting
RCDXB0553 sleeve C

Contact assembly with dielectric diameter over 1.4mm - without inner supporting sleeve
11.13±0.41 Outer hyring Inner pin Outer female contact
Strip lengths
YOC074 RMD26L-1 RCDX60-2
of cable 4.37
±0.41

Step 1: Step 2: Step 3:


- Assemble outer hyring onto cable - Insert the assembly into the outer female contact - Slide outer hyring forward against spring and
- Assemble inner pin to inner conductor and crimp until the inner pin snaps into place crimp in place as shown
- The cable braid (shield) should now cover the
barrel of the outer female contact as shown

Contact assembly with dielectric diameter under 1.4mm - with inner supporting sleeve
11.13±0.41 Outer hyring Supporting sleeve Inner pin Outer female contact
YOC074 RCDXB-055-1 RMD26L-1 RCDX60-2028
Strip lengths
6.35±0.41
of cable

Step 1: Step 2: Step 3:


- Assemble outer hyring onto cable - Insert the assembly into the outer female contact - Slide outer hyring forward against spring and
Appendices

- Assemble supporting sleeve over dielectric and under braid until the inner pin snaps into place crimp in place as shown
- Assemble inner pin to inner conductor, push back against - The cable braid (shield) should now cover the
sleeve and crimp barrel of the outer female contact as shown

Supporting
Outer hyring sleeve

Note : all dimensions are in mm

173
UTO Series | Appendices

#16 Coaxial Contacts (Continued)

Coax Cable with Monocrimp Contact Cabling

Inner conductor
Cable Male Female Crimp Die Stop Cable strip length Braid crimp
crimp
reference contact contact tool set bushing
A B C g dim t dim g dim t dim
CDC PIN22939200 RMDX6046D28 RCDX6016D28 S80 SL105 4.19 5.97 8.51 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84
CDC PIN22939200 RMDX6046D28 RCDX6016D28 S87 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84
CDC PIN245670000 RMDX6050D28 RCDX6016D28 S80 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
KX21TVT (europe)
RMDX6034D28 RCDX6034D28 S82 SL105 5.08 6.35 8.89 1.30/1.17 1.32/1.17 2.84/2.74 3.07/2.9
RG178 B/U
RG178 / BU RMDX6050D28 RCDX6016D28 S87 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84
ampex RMDX6032D28 RCDX6032D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
TI PN 920580 RMDX6024D28 RCDX6024D28 S82 SL105 5.08 6.35 8.89 1.35/1.19 1.42/1.27 2.87/2.74 3.07/2.9
RG174/U RMDX6032D28 RCDX6032D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
Honeywell PN 58000062 RMDX6026D28 RCDX6026D28 S82 SL105 5.08 6.35 8.89 1.35/1.19 1.42/1.27 2.87/2.74 3.07/2.9
RG188A/U RMDX6036D28 RCDX6036D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
RG316/U RMDX6036D28 RCDX6036D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
PRD PN M10SG8 ASSY'Y
RMDX6018D28 RCDX6018D28 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97
247AS-C1123-001 TOOL DIE SET
M10S1J STOP BUSHING
PRD PN 247AS-C1251 RMDX6018D28 RCDX6018D28 M10S1J TOOL 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97

raychem 5024A3111 RMDX6052D28 RCDX6052D28 S88 SL105 5.08 6.35 11.68 1.37/1.27 1.45/1.32 2.92/2.79
raychem 5026e1614 RMDX6036D28 RCDX6036D28 M10SG8 ASSY'Y 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97
TOOL DIE SET
JUDD C15013010902 RMDX6036D28 RCDX6036D28 STOP BUSHING 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97
M10S1J TOOL
inner cond. #30,
RMDX6050D28 - S80 SL105 5.1 6.35 8.9 - - - -
braid diam 2.64
inner cond. #30,
RMDX6050D28 - S87 SL105 4.2 6.35 8.5 - - - -
braid diam 2.29
inner cond. #28,
RMDX6032D28 RCDX6032D28 S80 SL105 5.1 6.35 11.7 - - - -
braid diam 2.9
inner cond. #26,
RMDX6024D28 RCDX6024D28 S82 SL105 5.1 6.35 8.9 - - - -
braid diam 1.78
inner cond. #26,
RMDX6026D28 RCDX6026D28 S82 SL105 5.1 6.35 8.9 - - - -
braid diam 3.05

• Select appropriate cable and contact combination.


• Select appropriate crimp tooling (hand tool, S-die set, stop bushing).
• Strip coax cable to the designated wire strip lengths. See cable strip lengths
• Insert the stripped coax into the rear of the contact.
• Crimp the contact.

Cable strip length


RMDX60
Male coax contact

A RCDX60
Female coax contact
B
C

Note : all dimensions are in mm

174
UTO Series | Appendices

Glossary of Terms
• Clearance • CTI (Comparative Tracking Index)
Per the IEC 60664-1 it is the shortest The CTI value is commonly used to characterise the electrical
distance between two conductive parts breakdown properties of an insulating material. It allows users
even over the air. to know the tendency to create creepage paths. This value
represents the maximum voltage after 50 drops of ammonium chloride
solution without any breakdown.
• Creepage distance
Per the IEC 60664-1 it represents the
shortest distance along the surface • RTI (Relative temperature Index):
of the insulating material between two Extract from ULs website:
conductive parts. Air gap Maximum service temperature for a material, where a class of
Creepage distance critical property will not be unacceptably compromised through
chemical thermal degradation, over the reasonable life of an
• Working voltage electrical product, relative to a reference material having a
Per the IEC 60664-1 it is the highest r.m.s. value of A.C. or D.C. voltage confirmed, acceptable corresponding performance defined RTI.
across any particular insulation which can occur when the equipment is
supplied at rated voltage. - RTI Elec: Electrical RTI, associated with critical electrical
insulating properties.

• Rated impulse voltage - RTI Mech Imp: Mechanical Impact RTI, associated with
Impulse withstands voltage value assigned by the manufacturer to critical impact resistance, resilience and flexibility properties.
the equipment or to a part of it characterizing the specified withstand
capability of its insulation against transient overvoltage. - RTI Mech Str: Mechanical Strength (Mechanical without
Impact) RTI, associated with critical mechanical strength where
impact resistance, resilience and flexibility are not essential.
• Working current
It is the maximum continuous and not interrupted current able to be
carried by all contacts without exceeding the maximum temperature of
the insulating material.

• Transient voltage
Extract from the IEC 60664-1: Short duration overvoltage of a few
millisecond or less, oscillatory or non-oscillatory, usually highly damped.

Appendices

175
UTO Series | Appendices

Drilling Pattern
Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm

Shell Size Dimensions (mm)

103 104 106 102W2 103W3

3.1
3
3

1.6

0.8
10

0.7
1.5

2.5
3.3

3
3
2.6 2.6 3 3 2.8 3 3 3 2.5

124 128 1210


2 1.6
3.1

3
0.9
4

12
4.5

2.8
3.1

3
3.1 3.1 4.4 3.4 4.9 3.3

142G1
147 148
5.2

5.2
4.2

2.5

0.4
2.1

2.4
5.3

2
3.6 3.6 6.4 3.2
4.5 5

14
1412 1492 1419
5.1 5.7 6.6 4.9
5.9

2 1.4 3.6 1.9


5.5

4.6

5.7
2.9

2.8
1.5

1.4
0.8
0.3

2.4

2.3
2.2

4.5

5.1
5.9

2.2 0.7 1.6 3.3


2.6 5.3
3.8 5.8

176
UTO Series | Appendices

Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm

Shell Size Dimensions (mm)

1619 7.7
1626
4.4 6
6.5 3.8 1.7 3.3

8.1
7.5

7.4

5.4
4.5
2.3
2.
1.6
1

16

0.9

0.8
2.8

3.8

4
5.1
6.6
2.7 1 3 1.7

7.9
7.5 4.8 4.5
7 8

1823 1832
8.7
5.3 7.2
3.1 4.8
8.3
2.4 1.6
5 6.7
5.4
1.9

7.7
8.9
5.8
7.7

5.5
2.4
4.9

18
2.4

0.8

6.7
8.6

3.8

8.5
4

9.1
5.6
3.4
4.8

3.5 3.7
1.6 3.3
4.4 6.1
5.7 8.1
9
Appendices

177
UTO Series | Appendices

Drilling Pattern (Continued)


Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm

Shell Size Dimensions (mm)

2028 2030
5.4 10.1 9.3
2.5 4.9 7.1 5.8
1.6 1.5 3.8 1.9

10.1
9.2
5.4

7.1
5.8

5.2
7
2.5

3.4

1.9
0.6
1.6
1.5

0.5
3.8
2.2

4.2
4.9

3.8
6.2
10

9.3
6
0.6 0.5
3.4 3.8 2041
20 5.7 4.2 5.9 10.6
7 6 3.3 6.2
10 9.2 2.9 3.2
10.1
7.2

6.2
3.2
6.3

2.3
0.8
4.0
3.4

0.8
6.9

2.5
3.8
8.5
10.6

5.3
1.7 1.6
4.7 3.7
7.1 6.7
10.1 8.5

2235 2238
6.7
3.9 5.5
1.9 3.3
11.6

11.4
8.4

7.9
10.2
6.2

6.7
4.2

4.6
2.2

3.9
6.5

0.1

0.9
2.5

22
1.4

1.9

1.9
2.8
5.5

3.9

11.6
10.1
8.1

6.3
7.8
11

9.1
6

0.3 1.6 3.7 7.1


2.2 4.9 7.8 8.5
5.7 8.2 9.7 10.6
9.6 11.5 11.2 11.5

178
UTO Series | Appendices

Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm

Shell Size Dimensions (mm)

2255

6.6
8.2

3.3
22

1.6
4.9
9.9
11.5

5.7 2.8
11.4 8.5

2448
11.4

7.6
3.8
1.9

2461
9.5

5.7
13.3

12.3
10.4 13.3
10.1 7.2
6.6 3.3 9.1 6.0
13.2 9.9 7.9 4.3
4.9 3.7
2.6 1.7

24 11.5
12.7

9.2
8.5
11
8.7

7.1
5.6
5.8
4.4

5
3.1
2.3
1.1

2.5
0.2

0.7
4.1
1

7.2
3.3
10.2

9.6
9.9
5.9
5.4
3.5

11.9
6.7

13.1
7.9

13.6

3.3 3.4
5.7 6.5
6.3 6.7
Appendices

8.6 9.3
9.9 11.5
11.5 12.9
13.6

179
UTO Series | Appendices

Discrimination/Keying Methods
In applications where similar connectors are used next to each other, Discrimination key degrees
mismatching can cause disturbances, system failure or even danger to Shell size Layout
operating personnel. W X Y Z

To eliminate mismatching, all Trim Trio® connectors are offered with 103 - - - -
discrimination keys to avoid interconnection system errors. In addition, 102W2 - - - -
the connector insert can also be rotated inside the shell to create custom
10 104 45° - - -
keying options.
103W3 - - - -
106 90° - - -
124 - - - -
12 128 26° - - -
1210 60° 155° 270° 295°
142G1 - - - -
147 - - - -
148 - - - -
14
1412 60° - - -
1492 49° 71° 145° -
1419 30° 165° 315° -
1619 30° 165° - 315°
16
1626 60° - 275° 338°
1823 - 158° - 270°
18
1832 85° 138° 222° 265°
2028 79° - 259° -
Connectors with rotated inserts can be ordered by adding the suffix W, X,
20 2030 34° 90° 123° 259°
Y or Z to the standard part number.
e.g. UT0W0106PH (standard key)  UT0W0106PWH (W key) 2041 45° 126° 225° -
2235 13° 162° 198° 265°
Consult us for overmoulded harnesses. 22 2238 15° 47° 150° 331°
2255 30° 142° 226° 314°
2448 60° 120° 189° 351°
24
2461 90° 180° 270° 324°

SMSPKE0 (only for UTO layouts using #16 contacts)

When one of these dummy contacts is used, the UTO connector


will only mate with a connector which has a vacant cavity at the
corresponding position.

The material used is polyamide 6.6. SMSPKE0

180
UTO Series | Appendices

Part Number Index


Connectors UT002235SH6................... P.100 UT062028SH02.................. P.88
UT00102W2PH................... P.32 UT002238PH.................... P.104 UT062030PH.................... P.92
UT00102W2PH6.................. P.32 UT002238PH6................... P.104 UT062030PH02.................. P.92
UT00102W2SH................... P.32 UT002238SH.................... P.104 UT062030SH.................... P.92
UT00102W2SH6.................. P.32 UT002238SH6................... P.104 UT062030SH02.................. P.92
UT00103PH..................... P.20 UT002448PH.................... P.112 UT062235PH.................... P.100
UT00103PH6.................... P.20 UT002448PH6................... P.112 UT062235PH02.................. P.100
UT00103SH..................... P.20 UT002448SH.................... P.112 UT062235SH.................... P.100
UT00103SH6.................... P.20 UT002448SH6................... P.112 UT062235SH02.................. P.100
UT00103W3PH................... P.40 UT06102W2PH................... P.32 UT062238PH.................... P.104
UT00103W3PH6.................. P.40 UT06102W2PH02................. P.32 UT062238PH02.................. P.104
UT00103W3SH................... P.40 UT06102W2SH................... P.32 UT062238SH.................... P.104
UT00103W3SH6.................. P.40 UT06102W2SH02................. P.32 UT062238SH02.................. P.104
UT00104PH..................... P.36 UT06103PH..................... P.20 UT062448PH.................... P.112
UT00104PH6.................... P.36 UT06103PH02................... P.20 UT062448PH02.................. P.112
UT00104SH..................... P.36 UT06103SH..................... P.20 UT062448SH.................... P.112
UT00104SH6.................... P.36 UT06103SH02................... P.20 UT062448SH02.................. P.112
UT00124PH..................... P.28 UT06103W3PH................... P.40 UT07102W2PH................... P.32
UT00124PH6.................... P.28 UT06103W3PH02................. P.40 UT07102W2PH01................. P.32
UT00124SH..................... P.28 UT06103W3SH................... P.40 UT07102W2PH6.................. P.32
UT00124SH6.................... P.28 UT06103W3SH02................. P.40 UT07102W2PH601................ P.32
UT00128PH..................... P.52 UT06104PH..................... P.36 UT07102W2SH................... P.32
UT00128PH6.................... P.52 UT06104PH02................... P.36 UT07102W2SH01................. P.32
UT00128SH..................... P.52 UT06104SH..................... P.36 UT07102W2SH6.................. P.32
UT00128SH6.................... P.52 UT06104SH02................... P.36 UT07102W2SH601................ P.32
UT001412PH.................... P.64 UT06124PH..................... P.28 UT07103PH..................... P.20
UT001412PH6................... P.64 UT06124PH02................... P.28 UT07103PH01................... P.20
UT001412SH.................... P.64 UT06124SH..................... P.28 UT07103PH6.................... P.20
UT001412SH6................... P.64 UT06124SH02................... P.28 UT07103PH601.................. P.20
UT00142G1PH................... P.24 UT06128PH..................... P.52 UT07103SH..................... P.20
UT00142G1PH6.................. P.24 UT06128PH02................... P.52 UT07103SH01................... P.20
UT00142G1SH................... P.24 UT06128SH..................... P.52 UT07103SH6.................... P.20
UT00142G1SH6.................. P.24 UT06128SH02................... P.52 UT07103SH601.................. P.20
UT00147PH..................... P.48 UT061412PH.................... P.64 UT07103W3PH................... P.40
UT00147PH6.................... P.48 UT061412PH02.................. P.64 UT07103W3PH01................. P.40
UT00147SH..................... P.48 UT061412SH.................... P.64 UT07103W3PH6.................. P.40
UT00147SH6.................... P.48 UT061412SH02.................. P.64 UT07103W3PH601................ P.40
UT00148PH..................... P.56 UT06142G1PH................... P.24 UT07103W3SH................... P.40
UT00148PH6.................... P.56 UT06142G1PH02................. P.24 UT07103W3SH01................. P.40
UT00148SH..................... P.56 UT06142G1SH................... P.24 UT07103W3SH6.................. P.40
UT00148SH6.................... P.56 UT06142G1SH02................. P.24 UT07103W3SH601................ P.40
UT001492PH.................... P.68 UT06147PH..................... P.48 UT07104PH..................... P.36
UT001492PH6................... P.68 UT06147PH02................... P.48 UT07104PH01................... P.36
UT001492SH.................... P.68 UT06147SH..................... P.48 UT07104PH6.................... P.36
UT001492SH6................... P.68 UT06147SH02................... P.48 UT07104PH601.................. P.36
UT001619PH.................... P.76 UT06148PH..................... P.56 UT07104SH..................... P.36
UT001619PH6................... P.76 UT06148PH02................... P.56 UT07104SH01................... P.36
UT001619SH.................... P.76 UT06148SH..................... P.56 UT07104SH6.................... P.36
UT001619SH6................... P.76 UT06148SH02................... P.56 UT07104SH601.................. P.36
UT001823PH.................... P.80 UT061492PH.................... P.68 UT07124PH..................... P.28
UT001823PH6................... P.80 UT061492PH02.................. P.68 UT07124PH01................... P.28
UT001823SH.................... P.80 UT061492SH.................... P.68 UT07124PH6.................... P.28
UT001823SH6................... P.80 UT061492SH02.................. P.68 UT07124PH601.................. P.28
UT002028PH.................... P.88 UT061619PH.................... P.76 UT07124SH..................... P.28
UT002028PH6................... P.88 UT061619PH02.................. P.76 UT07124SH01................... P.28
UT002028SH.................... P.88 UT061619SH.................... P.76 UT07124SH6.................... P.28
UT002028SH6................... P.88 UT061619SH02.................. P.76 UT07124SH601.................. P.28
UT002030PH.................... P.92 UT061823PH.................... P.80 UT07128PH..................... P.52
Appendices

UT002030PH6................... P.92 UT061823PH02.................. P.80 UT07128PH01................... P.52


UT002030SH.................... P.92 UT061823SH.................... P.80 UT07128PH6.................... P.52
UT002030SH6................... P.92 UT061823SH02.................. P.80 UT07128PH601.................. P.52
UT002235PH.................... P.100 UT062028PH.................... P.88 UT07128SH..................... P.52
UT002235PH6................... P.100 UT062028PH02.................. P.88 UT07128SH01................... P.52
UT002235SH.................... P.100 UT062028SH.................... P.88 UT07128SH6.................... P.52

181
UTO Series | Appendices

Part Number Index (Continued)


UT07128SH601.................. P.52 UT072028SH601................. P.88 UT0W02461SH6.................. P.120
UT071412PH.................... P.64 UT072030PH.................... P.92 UT0W6106PH.................... P.44
UT071412PH01.................. P.64 UT072030PH01.................. P.92 UT0W6106PH02.................. P.44
UT071412PH6................... P.64 UT072030PH6................... P.92 UT0W6106SH.................... P.44
UT071412PH601................. P.64 UT072030PH601................. P.92 UT0W6106SH02.................. P.44
UT071412SH.................... P.64 UT072030SH.................... P.92 UT0W61210PH................... P.60
UT071412SH01.................. P.64 UT072030SH01.................. P.92 UT0W61210PH02................. P.60
UT071412SH6................... P.64 UT072030SH6................... P.92 UT0W61210SH................... P.60
UT071412SH601................. P.64 UT072030SH601................. P.92 UT0W61210SH02................. P.60
UT07142G1PH................... P.24 UT072235PH.................... P.100 UT0W61419PH................... P.72
UT07142G1PH01................. P.24 UT072235PH01.................. P.100 UT0W61419PH02................. P.72
UT07142G1PH6.................. P.24 UT072235PH6................... P.100 UT0W61419SH................... P.72
UT07142G1PH601................ P.24 UT072235PH601................. P.100 UT0W61419SH02................. P.72
UT07142G1SH................... P.24 UT072235SH.................... P.100 UT0W61626PH................... P.84
UT07142G1SH01................. P.24 UT072235SH01.................. P.100 UT0W61626PH02................. P.84
UT07142G1SH6.................. P.24 UT072235SH6................... P.100 UT0W61626SH................... P.84
UT07142G1SH601................ P.24 UT072235SH601................. P.100 UT0W61626SH02................. P.84
UT07147PH..................... P.48 UT072238PH.................... P.104 UT0W61832PH................... P.96
UT07147PH01................... P.48 UT072238PH01.................. P.104 UT0W61832PH02................. P.96
UT07147PH6.................... P.48 UT072238PH6................... P.104 UT0W61832SH................... P.96
UT07147PH601.................. P.48 UT072238PH601................. P.104 UT0W61832SH02................. P.96
UT07147SH..................... P.48 UT072238SH.................... P.104 UT0W62041PH................... P.108
UT07147SH01................... P.48 UT072238SH01.................. P.104 UT0W62041PH02................. P.108
UT07147SH6.................... P.48 UT072238SH6................... P.104 UT0W62041SH................... P.108
UT07147SH601.................. P.48 UT072238SH601................. P.104 UT0W62041SH02................. P.108
UT07148PH..................... P.56 UT072448PH.................... P.112 UT0W62255PH................... P.116
UT07148PH01................... P.56 UT072448PH01.................. P.112 UT0W62255PH02................. P.116
UT07148PH6.................... P.56 UT072448PH6................... P.112 UT0W62255SH................... P.116
UT07148PH601.................. P.56 UT072448PH601................. P.112 UT0W62255SH02................. P.116
UT07148SH..................... P.56 UT072448SH.................... P.112 UT0W62461PH................... P.120
UT07148SH01................... P.56 UT072448SH01.................. P.112 UT0W62461PH02................. P.120
UT07148SH6.................... P.56 UT072448SH6................... P.112 UT0W62461SH................... P.120
UT07148SH601.................. P.56 UT072448SH601................. P.112 UT0W62461SH02................. P.120
UT071492PH.................... P.68 UT0W0106PH.................... P.44 UT0W7106PH.................... P.44
UT071492PH01.................. P.68 UT0W0106PH6................... P.44 UT0W7106PH01.................. P.44
UT071492PH6................... P.68 UT0W0106SH.................... P.44 UT0W7106PH6................... P.44
UT071492PH601................. P.68 UT0W0106SH6................... P.44 UT0W7106PH601................. P.44
UT071492SH.................... P.68 UT0W01210PH................... P.60 UT0W7106SH.................... P.44
UT071492SH01.................. P.68 UT0W01210PH6.................. P.60 UT0W7106SH01.................. P.44
UT071492SH6................... P.68 UT0W01210SH................... P.60 UT0W7106SH6................... P.44
UT071492SH601................. P.68 UT0W01210SH6.................. P.60 UT0W7106SH601................. P.44
UT071619PH.................... P.76 UT0W01419PH................... P.72 UT0W71210PH................... P.60
UT071619PH01.................. P.76 UT0W01419PH6.................. P.72 UT0W71210PH01................. P.60
UT071619PH6................... P.76 UT0W01419SH................... P.72 UT0W71210PH6.................. P.60
UT071619PH601................. P.76 UT0W01419SH6.................. P.72 UT0W71210PH601................ P.60
UT071619SH.................... P.76 UT0W01626PH................... P.84 UT0W71210SH................... P.60
UT071619SH01.................. P.76 UT0W01626PH6.................. P.84 UT0W71210SH01................. P.60
UT071619SH6................... P.76 UT0W01626SH................... P.84 UT0W71210SH6.................. P.60
UT071619SH601................. P.76 UT0W01626SH6.................. P.84 UT0W71210SH601................ P.60
UT071823PH.................... P.80 UT0W01832PH................... P.96 UT0W71419PH................... P.72
UT071823PH01.................. P.80 UT0W01832PH6.................. P.96 UT0W71419PH01................. P.72
UT071823PH6................... P.80 UT0W01832SH................... P.96 UT0W71419PH6.................. P.72
UT071823PH601................. P.80 UT0W01832SH6.................. P.96 UT0W71419PH601................ P.72
UT071823SH.................... P.80 UT0W02041PH................... P.108 UT0W71419SH................... P.72
UT071823SH01.................. P.80 UT0W02041PH6.................. P.108 UT0W71419SH01................. P.72
UT071823SH6................... P.80 UT0W02041SH................... P.108 UT0W71419SH6.................. P.72
UT071823SH601................. P.80 UT0W02041SH6.................. P.108 UT0W71419SH601................ P.72
UT072028PH.................... P.88 UT0W02255PH................... P.116 UT0W71626PH................... P.84
UT072028PH01.................. P.88 UT0W02255PH6.................. P.116 UT0W71626PH01................. P.84
UT072028PH6................... P.88 UT0W02255SH................... P.116 UT0W71626PH6.................. P.84
UT072028PH601................. P.88 UT0W02255SH6.................. P.116 UT0W71626PH601................ P.84
UT072028SH.................... P.88 UT0W02461PH................... P.120 UT0W71626SH................... P.84
UT072028SH01.................. P.88 UT0W02461PH6.................. P.120 UT0W71626SH01................. P.84
UT072028SH6................... P.88 UT0W02461SH................... P.120 UT0W71626SH6.................. P.84

182
UTO Series | Appendices

UT0W71626SH601................ P.84 UT016JCS...................... P.76 UT0S20JCSL.................... P.88


UT0W71832PH................... P.96 UT016JCSL..................... P.76 UT0S22JC...................... P.100
UT0W71832PH01................. P.96 UT016LPGN..................... P.76 UT0S22JCL..................... P.100
UT0W71832PH6.................. P.96 UT018AC....................... P.80 UT0S22JCPGN................... P.100
UT0W71832PH601................ P.96 UT018AD....................... P.80 UT0S22JCS..................... P.100
UT0W71832SH................... P.96 UT018JC....................... P.80 UT0S22JCSL.................... P.100
UT0W71832SH01................. P.96 UT018JCL...................... P.80 UT0S24JC...................... P.112
UT0W71832SH6.................. P.96 UT018JCS...................... P.80 UT0S24JCL..................... P.112
UT0W71832SH601................ P.96 UT018JCPGN.................... P.80 UT0S24JCPGN................... P.112
UT0W72041PH................... P.108 UT018JCSL..................... P.80 UT0S24JCS..................... P.112
UT0W72041PH01................. P.108 UT018LPGN..................... P.80 UT0S24JCSL.................... P.112
UT0W72041PH6.................. P.108 UT020AC....................... P.88
UT0W72041PH601................ P.108 UT020AD....................... P.88 Accessories
UT0W72041SH................... P.108 UT020JC....................... P.88 SMSPKE0....................... P.180
UT0W72041SH01................. P.108 UT020JCL...................... P.88 UT010DCG...................... P.22
UT0W72041SH6.................. P.108 UT020JCS...................... P.88 UT012DCG...................... P.30
UT0W72041SH601................ P.108 UT020JCPGN.................... P.88 UT014DCG...................... P.26
UT0W72255PH................... P.116 UT020JCSL..................... P.88 UT016DCG...................... P.78
UT0W72255PH01................. P.116 UT020LPGN..................... P.88 UT018DCG...................... P.82
UT0W72255PH6.................. P.116 UT022AC....................... P.100 UT020DCG...................... P.90
UT0W72255PH601................ P.116 UT022AD....................... P.100 UT022DCG...................... P.102
UT0W72255SH................... P.116 UT022JC....................... P.100 UT024DCG...................... P.114
UT0W72255SH01................. P.116 UT022JCL...................... P.100 UTFD12B....................... P.22
UT0W72255SH6.................. P.116 UT022JCS...................... P.100 UTFD13B....................... P.30
UT0W72255SH601................ P.116 UT022JCPGN.................... P.100 UTFD14B....................... P.26
UT0W72461PH................... P.120 UT022JCSL..................... P.100 UTFD15B....................... P.78
UT0W72461PH01................. P.120 UT022LPGN..................... P.100 UTFD16B....................... P.82
UT0W72461PH6.................. P.120 UT024AC....................... P.112 UTFD17B....................... P.90
UT0W72461PH601................ P.120 UT024AD....................... P.112 UTFD18B....................... P.102
UT0W72461SH................... P.120 UT024JC....................... P.112 UTFD19B....................... P.114
UT0W72461SH01................. P.120 UT024JCL...................... P.112 UTG610DCG..................... P.22
UT0W72461SH6.................. P.120 UT024JCS...................... P.112 UTG612DCG..................... P.30
UT0W72461SH601................ P.120 UT024JCPGN.................... P.112 UTG614DCG..................... P.26
UT024JCSL..................... P.112 UTG616DCG..................... P.78
Backshells UT024LPGN..................... P.112 UTG618DCG..................... P.82
UT010AC....................... P.20 UT0S10JC...................... P.20 UTG620DCG..................... P.90
UT010AD....................... P.20 UT0S10JCL..................... P.20 UTG622DCG..................... P.102
UT010JC....................... P.20 UT0S10JCPGN................... P.20 UTG624DCG..................... P.114
UT010JCL...................... P.20 UT0S10JCS..................... P.20
UT010JCPGN.................... P.20 UT0S10JCSL.................... P.20 Contacts
UT010JCS...................... P.20 UT0S12JC...................... P.28 82911456A..................... P.129
UT010JCSL..................... P.20 UT0S12JCL..................... P.28 82911456K..................... P.129
UT010LPGN..................... P.20 UT0S12JCS..................... P.28 82911457NA.................... P.129
UT012AC....................... P.28 UT0S12JCPGN................... P.28 82911457NK.................... P.129
UT012AD....................... P.28 UT0S12JCSL.................... P.28 82911458A..................... P.129
UT012JC....................... P.28 UT0S14JC...................... P.24 82911458K..................... P.129
UT012JCL...................... P.28 UT0S14JCL..................... P.24 82911459NA.................... P.129
UT012JCPGN.................... P.28 UT0S14JCPGN................... P.24 82911459NK.................... P.129
UT012JCS...................... P.28 UT0S14JCS..................... P.24 82911460A..................... P.129
UT012JCSL..................... P.28 UT0S14JCSL.................... P.24 82911460K..................... P.129
UT012LPGN..................... P.28 UT0S16JC...................... P.76 82911461NA.................... P.129
UT014AC....................... P.24 UT0S16JCL..................... P.76 82911461NK.................... P.129
UT014AD....................... P.24 UT0S16JCPGN................... P.76 82911462A..................... P.129
UT014JC....................... P.24 UT0S16JCS..................... P.76 82911462K..................... P.129
UT014JCL...................... P.24 UT0S16JCSL.................... P.76 82911463NA.................... P.129
UT014LPGN..................... P.24 UT0S18JC...................... P.80 82911463NK.................... P.129
UT014JCPGN.................... P.24 UT0S18JCL..................... P.80 82911464A..................... P.129
UT014JCSL..................... P.24 UT0S18JCPGN................... P.80 82911464K..................... P.129
Appendices

UT014LPGN..................... P.24 UT0S18JCS..................... P.80 82911465NA.................... P.129


UT016AC....................... P.76 UT0S18JCSL.................... P.80 82911465NK.................... P.129
UT016AD....................... P.76 UT0S20JC...................... P.88 82911466A..................... P.129
UT016JC....................... P.76 UT0S20JCL..................... P.88 82911466K..................... P.129
UT016JCL...................... P.76 UT0S20JCPGN................... P.88 82911467NA.................... P.129
UT016JCPGN.................... P.76 UT0S20JCS..................... P.88 82911467NK.................... P.129

183
UTO Series | Appendices

Part Number Index (Continued)


82913600A..................... P.129 RM20M12E8K.................... P.132 SM14M1TK6..................... P.129
82913601A..................... P.129 RM20M12E83J................... P.132 SM14ML1S18.................... P.129
82913602A..................... P.129 RM20M12E83K................... P.132 SM14ML1S31.................... P.129
82913603A..................... P.129 RM20M12GE1J................... P.130 SM14ML1TK6.................... P.129
82913604A..................... P.129 RM20M12GE1K................... P.130 SM16M1S18..................... P.129
82913605A..................... P.129 RM20M13J...................... P.129 SM16M1S31..................... P.129
82913606A..................... P.129 RM20M13K...................... P.129 SM16M1TK6..................... P.129
82913607A..................... P.129 RM20M13GE1J................... P.130 SM16M11S18.................... P.129
82913608A..................... P.129 RM20M13GE1K................... P.130 SM16M11S31.................... P.129
82913609A..................... P.129 RM20W3K....................... P.129 SM16M11TK6.................... P.129
82911684NPC................... P.132 RM24M9J....................... P.129 SM16ML1S18.................... P.129
82911684NAPC.................. P.132 RM24M9K....................... P.129 SM16ML1S31.................... P.129
82911685NPC................... P.132 RM24M9GE1J.................... P.130 SM16ML1TK6.................... P.129
82911685NAPC.................. P.132 RM24M9GE1K.................... P.130 SM16ML11S18................... P.129
RC14M30J...................... P.129 RM24W3K....................... P.129 SM16ML11S31................... P.129
RC14M30K...................... P.129 RM28M1J....................... P.129 SM16ML11TK6................... P.129
RC14M30GE7J................... P.130 RM28M1K....................... P.129 SM20M1S18..................... P.129
RC14M30GE7K................... P.130 RM28M1GE1J.................... P.130 SM20M1S31..................... P.129
RC16M23J...................... P.129 RM28M1GE1K.................... P.130 SM20M1TK6..................... P.129
RC16M23K...................... P.129 RMDX60xxD28................... P.131 SM20ML1S18.................... P.129
RC16M23GE7J................... P.130 RMDXK10D28.................... P.131 SM20ML1S31.................... P.129
RC16M23GE7K................... P.130 RMPOF1000..................... P.130 SM20ML1TK6.................... P.129
RC18W3K....................... P.129 RMW5016K...................... P.132 SM20W3S26..................... P.129
RC20M12J...................... P.129 RMW50A7K...................... P.132 SM20W3TK6..................... P.129
RC20M12K...................... P.129 SC14M1S18..................... P.129 SM20WL3S26.................... P.129
RC20M12E8J.................... P.132 SC14M1S31..................... P.129 SM20WL3TK6.................... P.129
RC20M12E8K.................... P.132 SC14M1TK6..................... P.129 SM24M1S18..................... P.129
RC20M12E83J................... P.132 SC14ML1S18.................... P.129 SM24M1S31..................... P.129
RC20M12E83K................... P.132 SC14ML1S31.................... P.129 SM24M1TK6..................... P.129
RC20M12E84J................... P.132 SC14ML1TK6.................... P.129 SM24ML1S18.................... P.129
RC20M12E84K................... P.132 SC16M1S18..................... P.129 SM24ML1S31.................... P.129
RC20M12GE7J................... P.130 SC16M1S31..................... P.129 SM24ML1TK6.................... P.129
RC20M12GE7K................... P.130 SC16M1TK6..................... P.129 SM24W3S26..................... P.129
RC20M13J...................... P.129 SC16M11S18.................... P.129 SM24W3TK6..................... P.129
RC20M13K...................... P.129 SC16M11S31.................... P.129 SM24WL3S26.................... P.129
RC20M13GE7J................... P.130 SC16M11TK6.................... P.129 SM24WL3TK6.................... P.129
RC20M13GE7K................... P.130 SC16ML1S18.................... P.129
RC20W3K....................... P.129 SC16ML1S31.................... P.129 Tooling
RC24M9J....................... P.129 SC16ML1TK6.................... P.129 51060210924................... P.139
RC24M9K....................... P.129 SC16ML11S18................... P.129 51060210936................... P.139
RC24M9GE7J.................... P.130 SC16ML11S31................... P.129 M10S1J........................ P.174
RC24M9GE7K.................... P.130 SC16ML11TK6................... P.129 M10SG8........................ P.174
RC24W3K....................... P.129 SC20M1S18..................... P.129 M317.......................... P.139
RC28M1J....................... P.129 SC20M1S31..................... P.129 MH860......................... P.139
RC28M1K....................... P.129 SC20M1TK6..................... P.129 MH86164G...................... P.139
RC28M1GE7J.................... P.130 SC20ML1S18.................... P.129 MH86186....................... P.139
RC28M1GE7K.................... P.130 SC20ML1S31.................... P.129 RX2025GE1..................... P.139
RCDX60xxD28................... P.131 SC20ML1TK6.................... P.129 RX20D44....................... P.139
RCDXK1D28..................... P.131 SC20W3S25..................... P.129 S16RCM14...................... P.139
RCPOF1000B.................... P.130 SC20W3TK6..................... P.129 S16RCM16...................... P.139
RCW5016K...................... P.132 SC20WL3S25.................... P.129 S16RCM20...................... P.139
RCW50A7K...................... P.132 SC20WL3TK6.................... P.129 S16SCM20...................... P.139
RM14M30J...................... P.129 SC24M1S18..................... P.129 S16SCML1...................... P.139
RM14M30K...................... P.129 SC24M1S31..................... P.129 S16SCML11..................... P.139
RM14M30GE1J................... P.130 SC24M1TK6..................... P.129 S20RCM........................ P.139
RM14M30GE1K................... P.130 SC24ML1S18.................... P.129 S20SCM20...................... P.139
RM16M23J...................... P.129 SC24ML1S31.................... P.129 S221.......................... P.172
RM16M23K...................... P.129 SC24ML1TK6.................... P.129 S23D2......................... P.172
RM16M23GE1J................... P.130 SC24W3S25..................... P.129 S80........................... P.174
RM16M23GE1K................... P.130 SC24W3TK6..................... P.129 S82........................... P.174
RM18W3K....................... P.129 SC24WL3S25.................... P.129 S83........................... P.171
RM20M12J...................... P.129 SC24WL3TK6.................... P.129 S87........................... P.174
RM20M12K...................... P.129 SM14M1S18..................... P.129 S88........................... P.174
RM20M12E8J.................... P.132 SM14M1S31..................... P.129 SHANDLES...................... P.139

184
UTO Series | Appendices

SL105......................... P.174
SL46D2........................ P.172
SL471......................... P.172
UH25.......................... P.139
VGE10077A..................... P.139
VGE10078A..................... P.139

Appendices

185
UTO Series | Appendices

Notes

186
Your local contact

[email protected]
www.souriau-industrial.com
protection:

certified paper
Advancement of sustainable
This catalog is printed on PEFC

wood cultivation. www.pefc.org


Our contribution to environmental

CAUTOEUSEN01 © Copyright SOURIAU Oct 2013 - SOURIAU is a registered trademark


All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.