SOURIAU Conectores
SOURIAU Conectores
Overview
Contents
Overview Contacts
Typical Applications ........................................... 06 Description ........................................................ 126
Connector
Features & Benefits ........................................... 07 Contact Plating Selector Guide ......................... 127
Range Overview ................................................ 08 Contact Selector Guide ..................................... 128
Layouts .............................................................. 10 Packaging .......................................................... 128
General Technical Characteristics ...................... 12 Crimp Contacts ................................................. 129
#16 Coaxial Contacts ........................................ 131
PCB Contacts .................................................... 132
Fiber Optic Contacts ......................................... 133
Contacts
Cable Assembly ................................................. 16 Tooling ............................................................... 139
2 contacts + ground .......................................... 20 Crimping Instructions ........................................ 140
3 contacts + ground .......................................... 28 Handle & Interchangeable Heads ..................... 142
4 contacts .......................................................... 32 Extraction Tools ................................................. 143
Dimensions Overmoulded Harnesses ............... 143
Technical Information
6 contacts .......................................................... 40
6 contacts + ground .......................................... 48 Assembly Instructions ........................................ 144
8 contacts .......................................................... 52 Mated Connector Length .................................. 153
10 contacts ........................................................ 60 Rated Current & Working Voltage ..................... 155
12 contacts ........................................................ 64 Shielding Effectiveness/Corrosion ..................... 156
19 contacts ........................................................ 72 UL94 + UL1977 .................................................. 157
23 contacts ........................................................ 80 IEC 61984 with IP Code Explanation ................. 160
26 contacts ........................................................ 84 IEC 61140 Explained ......................................... 162
28 contacts ........................................................ 88 What is NEMA Rating ? ..................................... 163
30 contacts ........................................................ 92 Ethernet for the Layman .................................... 164
32 contacts ........................................................ 96
35 contacts ........................................................ 100 Appendices
38 contacts ........................................................ 104 #16 Coaxial Contacts/Cabling Notices ............. 168
Appendices
3
UTO SERIES
Overview
Typical Applications ................................................................................................. 06
Layouts .................................................................................................................... 10
5
UTO Series | Overview
Typical Applications
6
UTO Series | Overview
Overview
EMI Shielded
65 dB at 100 Mhz: Qualified and compatible to be used in
Signal electromagnetic radiation areas and ensures proper signal integrity and
integrity transmission.
7
UTO Series | Overview
Range
Single Wire
Sealing
Straight
Strain Relief
Right Angle
Strain Relief
Long Cable
Gland
UTO Series
Sealed: IP68/69K
Shielded
Corrosion resistant
UL compliant
Overmoulded
8
UTO Series | Overview
Overview
Overview
Single Wire
Sealing
Straight
Receptacle Choice of Crimp Contacts
• machined
Strain Relief
• stamped and formed
• coaxial
• fiber optics
PCB Contact
Heat Shrink Boot
Adapter
9
UTO Series | Overview
Shell size Contact #16 (Ø 1.6) Contact #20 (Ø 1.0) Contact #8 (Ø 3.6) Mixed Power
Page 68
1619* 1626
9A 150V 4A 40V
19 contacts 26 contacts
19xØ1.6 (#16) 26xØ1.0 (#20)
16
Page 76 Page 84
10
UTO Series | Overview
1823 1832
8A 150V 4A 50V
23 contacts 32 contacts
23xØ1.6 (#16) 32xØ1.0 (#20)
18
Overview
Page 80 Page 96
20
22
2448 2461
6A 160V 3A 80V
48 contacts 61 contacts
48xØ1.6 (#16) 61xØ1.0 (#20)
24
11
UTO Series | Overview
12
UTO Series | Overview
Overview
13
UTO SERIES
Connector
Upgrade of the UTO Series ..................................................................................... 16
Cable Assembly ....................................................................................................... 17
2 contacts + ground
103: 10A 500V.................................................................... 20
142G1: 44A 600V.................................................................... 24
3 contacts + ground
124: 16A 500V.................................................................... 28
4 contacts
102W2: 20A 500V.................................................................... 32
104*: 10A 500V.................................................................... 36
6 contacts
103W3: 5A 250V.................................................................... 40
106*: 5A 250V.................................................................... 44
6 contacts + ground
147: 10A 500V.................................................................... 48
8 contacts
128: 10A 500V.................................................................... 52.
148: 25A 250V.................................................................... 56
10 contacts
1210*: 5A 250V.................................................................... 60
12 contacts
1412: 10A 500V.................................................................... 64.
1492: 10A 500V.................................................................... 68
19 contacts
1419: 5A 250V.................................................................... 72
1619*: 9A 500V.................................................................... 76
23 contacts
1823: 8A 500V.................................................................... 80
26 contacts
1626: 4A 250V.................................................................... 84
28 contacts
2028: 5A 500V.................................................................... 88
30 contacts
2030: 5A 500V.................................................................... 92
32 contacts
1832: 4A 250V.................................................................... 96
35 contacts
2235: 5A 500V.................................................................... 100
38 contacts
2238: 5A 500V.................................................................... 104
41 contacts
2041: 3A 250V.................................................................... 108
48 contacts
2448: 5A 500V.................................................................... 112
55 contacts
2255: 3A 250V.................................................................... 116
61 contacts
2461: 3A 250V.................................................................... 120
Electrical parameters according to UL1977 * Ethernet compatible see pages 164 & 165
15
UTO Series | Connector
Description of change:
To better meet the demanding requirements and diversity of industrial markets/applications, Souriau changed the position of the wavy
washer inside the plug. This slight modification makes the new version of the UTO sealed to IP68/69K in dynamic conditions.
Old part number New part number connector New part number backshell Comments
UTO0/6-S/PT UT00/6-S/PH(6) - -
UTO0-S/PHT UT00-S/PH(6) - -
UTO0/6AC-S/PT UT00/6-S/PH(6) - -
UTO0/6PG-S/PHT UT00/6-S/PH(6) UT0-AC -
UTO-21/22- Keep old part number UT0-JC Silksreen version
UTO-44/45- Keep old part number - Screw coupling version
UTO-ACT - UT0-AC 851 backshell Nickel plated
Longer threading on connector side
UTO-PGT - UT0-JC
+ metric cable gland
Longer threading on connector side
UTOS-PGT - UT0S-JC
+ shielded metric cable gland
U-AD01T UT0-AD01 UT0-AD01 Longer threading to achieve sealing
Used on old UT06-45N screw
U-AD01N Keep old part number -
coupling version
16
UTO Series | Connector
Cable Assembly
SOURIAU has provided connectors for various applications for more than 90 years and has been used in the most extreme environments.
Conscious about the difficulty in finding a quick and reliable harness manufacturer, we began our own in-house cable assembly production.
It allows customers to reduce the number of suppliers and to take advantage of the “best in class” quality of the SOURIAU group.
Overmoulding is a process that further enhances the sealing properties and helps to minimize stress on the cable termination to the
connector. In addition, the wires are encapsulated inside the molding which creates a barrier preventing liquid/moisture from entering the
equipment through the connector or cable jacket if breached.
Connector
How to choose the outer jacket material
Please consult us
TPE
Cleaner,
chlorine
OUTDOOR FEP
Immersed
Static installation
(black outer jacket)
UV resistance
Chemical aggression
PUR PTFE
Static installation
Static or dynamic installation
INDOOR
Wet
PVC
Static installation
17
UTO Series | Connector
Overmoulding Description
O-ring
Compound Braid Cable outer
sheath
PVC or PUR
Thermoplastic insert Overmoulding overmoulding
adapter
Discrete connector
GOOD
Overmoulded connector
BEST
18
UTO Series | Connector
Cable
• TPE outer sheath (black)
• 300V
• Shielded
• Flammability rating UL 1581
Sec.1080 (VW-1)
Applications
• Machining Centers (Oil Resistant)
• Assembly Automation
Equipment
Connector
• Geophysical Equipment
• Solar (UV Stable)
• Outdoor Displays
Specifications
Custom Capabilities
Harness with custom cable Harness with double ends Y or T shape connection
19
UTO Series | Connector
OR OR OR OR Layout
WITH
Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC
20
16A/150V
UTO Series | Connector
per IEC 61984
Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 23.8 33 maxi 21.8
11.3
Male Male
Ø 20.0
Female Female
1.6
18.2 25.5 maxi
25.2 maxi
18.2
16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9 mounting
22.2 18.2
33 maxi Ø 17.3
31.0 24.7
Short version - 49.1 Short version - 49.1
Ø 16.3
Ø 21.0
21.6
48.0
Short version - 59.1 Short version - 60.1 60.6
30.0
21
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT010DC
22
16A/150V
UTO Series | Connector
per IEC 61984
Contacts
Part number Max Max
#16 Contact type AWG
wire Ø insulator Ø
Male Female
30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00
26-24 RM24M9K (1)
RC24M9K (1)
0.80 1.60
22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80
Machined
22-20 RM20M12K (1)
RC20M12K (1)
1.15 2.20
20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20
Crimp
UL 30
28
10A 500V UL94 V-0 25
Test 23
conditions 20
CSA 18
Contact used: 15
7A 500V UL94 V-0 Machined contacts 13
Wires used: 10
1.31mm² 8
IEC 5
23
UTO Series | Connector
OR OR OR OR Layout
WITH
Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC
24
40A/250V
UTO Series | Connector
per IEC 61984
Dimensions
Square Flange - UTO0 Plug - UTO6
33.3 maxi 28.6 34 maxi 29.3
11.3
Male Male
Ø 26.8
Female Female
1.6
23.0 34
33 maxi
23.0
24.1
Front
.5
mounting 25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25
34.0 24.7
Short version - 52.1 Short version - 53.1
Ø 22.5
Ø 27.0
27.4
52.0
Short version - 65.1 Short version - 65.1 67.7
36.5
25
UTO Series | Connector
Part number
VGE10078A
Extraction Tool #8
Part number
51060210936
26
40A/250V
UTO Series | Connector
per IEC 61984
Contacts
Part number Max Max
#8 Contact type AWG
wire Ø insulator Ø
Male Female
16 82913601A 82913600A 1.72
14 82913603A 82913602A 2.22
Crimp
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(3): For dimensions see page 132
UL 45
40
44A 600V UL94 V-0
Test 35
conditions 30
CSA 25
Contact used:
30A 600V UL94 V-0 Machined contacts
20
15
Wires used:
6mm² 10
IEC 5
27
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT012JCS UT012JC
28
16A/150V
UTO Series | Connector
per IEC 61984
Ø 23.6
Female Female
1.6
20.6 25.5 maxi
25.2 maxi
20.6
21.0
Front
mounting .2
22
Ø 18.4
Female Rear
17.9 mounting
27 20.6
33 maxi Ø 21.8
31.5 24.7
Short version - 49.1 Short version - 50.1
Ø 19.4
Ø 27.0
25.0
50.0
Short version - 62.1 Short version - 62.1 62.7
33.5
29
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT012DC
30
16A/150V
UTO Series | Connector
per IEC 61984
UL 28
25
16A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
13A 500V UL94 V-0 Machined contacts
13
10
Wires used:
8
1.31mm²
IEC 5
3
16A 150V 2.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
31
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC
32
25A/200V
UTO Series | Connector
per IEC 61984
Ø 20
Female Female
1.6
18.2 25.5 maxi
32 maxi
18.2
16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9
22.2 mounting
33 maxi 18.2 Ø 17.3
31.0 24.7
Short version - 49.1 Short version - 49.1
Ø 16.3
Ø 21.0
21.6
48.0
Short version - 59.1 Short version - 60.1 60.6
30.0
33
UTO Series | Connector
Gasket
Part number
Contacts Contact size
Part number / Neoprene of head
RM/RC 24W3K(1) S20RCM*
UTFD12B
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Crimp Tooling #12
Handle Head Complete set
Part number
Extraction Tool
51060210924
* For dustcap without chain, skip "G", e.g. UT010DC
34
25A/200V
UTO Series | Connector
per IEC 61984
#12
22 82911457NA 82911456A 0.87
20 82911459NA 82911458A 1.12
18 82911461NA 82911460A 1.42
Crimp
Machined 4.90
16 82911463NA 82911462A 1.72
14 82911465NA 82911464A 2.22
12 82911467NA 82911466A 2.82
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 or SM24WL3S26
(3): For dimensions see page 132
UL 45
Test 35
conditions 30
CSA 25
Contact used:
18A 500V UL94 V-0 Machined contacts 20
Wires used: 15
0.518mm²
IEC 3.300mm²
10
5
25A 200V 3kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
35
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC
36
13A/150V
UTO Series | Connector
per IEC 61984
Ø 20
Female Female
1.6
18.2 25.5 maxi
25.2 maxi
18.2
16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9
22.2 mounting
33 maxi 18.2 Ø 17.3
Ø 22.0
Ø 21.0
21.6
Fig. 3 Fig. 4
Fig. 7 Fig. 8
37
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT010DC
38
13A/150V
UTO Series | Connector
per IEC 61984
UL 30
28
10A 500V UL94 V-0 25
Test 23
conditions 20
CSA 18
Contact used: 15
7A 500V UL94 V-0 Machined contacts 13
Wires used: 10
1.31mm² 8
IEC 5
39
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC
40
5A/40V
UTO Series | Connector
per IEC 61984
Ø 20
Female Female
1.6
18.2 27 maxi
25.2 maxi
18.2
16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9
22.2 mounting
33 maxi 18.2 Ø 17.3
31.0 24.7
Short version - 49.1 Short version - 49.1
Ø 16.3
Ø 21.0
21.6
48.0
Short version - 59.1 Short version - 60.1 60.6
30.0
41
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT010DC
42
5A/40V
UTO Series | Connector
per IEC 61984
#20
26-24 RM24W3K RC24W3K 0.80 1.60
Machined 22-20 RM20W3K RC20W3K 1.15 1.60
20-18 RM18W3K RC18W3K 1.30 2.10
Crimp
30
UL 28
43
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 3/6 UT010JCS UT010JC
44
7A/80V
UTO Series | Connector
per IEC 61984
Ø 20
Female Female
1.6
18.2 25.5 maxi
25.2 maxi
18.2
16.5
Front
mounting .4
17
Ø 14.2
Female Rear
17.9
22.2 mounting
33 maxi 18.2 Ø 17.3
31.0 24.7
Short version - 49.1 Short version - 49.1
Ø 16.3
Ø 21.0
21.6
48.0
Short version - 59.1 Short version - 60.1 60.6
30.0
45
UTO Series | Connector
Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Handle Head Complete set
Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT024DC
46
7A/80V
UTO Series | Connector
per IEC 61984
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132
UL 14
Test 10
conditions
CSA 8
Contact used:
4A 250V UL94 V-0 Machined contacts 6
Wires used:
4
0.518mm²
IEC 2
7A 80V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
47
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC
48
16A/150V
UTO Series | Connector
per IEC 61984
Ø 26.8
Female Female
1.6
23.0 25.5 maxi
25.2 maxi
23.0
24.1
Front
mounting .5
25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25
Ø 29.8
Ø 27.0
27.4
Fig. 3 Fig. 4
Fig. 7 Fig. 8
49
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT014DC
50
16A/150V
UTO Series | Connector
per IEC 61984
UL 28
25
10A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
8
1.31mm²
IEC 5
51
UTO Series | Connector
OR
single wire sealing (1)
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT012JCS UT012JC
52
10A/125V
UTO Series | Connector
per IEC 61984
Ø 23.6
Female Female 8
1.6
20.6 25.5 maxi
25.2 maxi
20.6
21.0
Front
mounting .2
22
Ø 18.4
Female Rear
17.9 mounting
27 20.6
33 maxi Ø 21.8
Ø 25.4
Ø 27.0
25.0
Fig. 3 Fig. 4
Fig. 7 Fig. 8
53
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT012DC
54
10A/125V
UTO Series | Connector
per IEC 61984
UL 28
25
10A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
55
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC
56
17A/230V
UTO Series | Connector
per IEC 61984
Ø 26.8
Female Female 8
1.6
23.0 33 maxi
32 maxi
23.0
24.1
Front
.5
mounting 25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25
34.0 24.7
Short version - 52.1 Short version - 53.1
Ø 22.5
Ø 27.0
27.4
52.0
Short version - 65.1 Short version - 65.1 67.7
36.5
57
UTO Series | Connector
Part number
Extraction Tool
51060210924
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT014DC
58
17A/230V
UTO Series | Connector
per IEC 61984
#12
22 82911457NA 82911456A 0.87
20 82911459NA 82911458A 1.12
18 82911461NA 82911460A 1.42
Crimp
Machined 4.90
16 82911463NA 82911462A 1.72
14 82911465NA 82911464A 2.22
12 82911467NA 82911466A 2.82
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6
(3): For dimensions see page 132
UL 40
Contact used:
17A 250V UL94 V-0 Machined contacts
20
15
Wires used:
1.31mm² 10
IEC 3.30mm²
5
17A 230V 1.5kV 3 0
0 25 45 65 85 105 125
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
59
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT012JCS UT012JC
60
6A/40V
UTO Series | Connector
per IEC 61984
Ø 23.6
Female Female
1.6
20.6 25.5 maxi
25.2 maxi
10
20.6
21.0
Front
mounting .2
22
Ø 18.4
Female Rear
17.9 mounting
27 20.6
33 maxi Ø 21.8
31.5 24.7
Short version - 49.1 Short version - 50.1
Ø 19.4
Ø 27.0
25.0
50.0
Short version - 62.1 Short version - 62.1 62.7
33.5
61
UTO Series | Connector
Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Handle Head Complete set
Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT012DC
62
6A/40V
UTO Series | Connector
per IEC 61984
10
PCB
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132
UL 12
CSA
Contact used: 6
4A 250V UL94 V-0 Machined contacts
Wires used: 4
0.518mm²
IEC 2
6A 40V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
63
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC
64
10A/150V
UTO Series | Connector
per IEC 61984
Ø 26.8
Female Female
1.6
23.0 25.5 maxi
25.2 maxi
23.0
24.1
Front
mounting .5
25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25
Ø 29.8
Ø 27.0
27.4
Fig. 3 Fig. 4
Fig. 7 Fig. 8
65
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT014DC
66
10A/150V
UTO Series | Connector
per IEC 61984
UL 28
25
10A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
67
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC
68
10A/150V
UTO Series | Connector
per IEC 61984
Ø 26.8
Female Female
1.6
23.0 25.5 maxi
25.2 maxi
23.0
24.1
Front
.5
mounting 25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25
34.0 24.7
Short version - 52.1 Short version - 53.1
Ø 22.5
Ø 27.0
27.4
52.0
Short version - 65.1 Short version - 65.1 67.7
36.5
69
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT014DC
70
10A/150V
UTO Series | Connector
per IEC 61984
UL 28
25
10A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
71
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 06/10 UT014JCS UT014JC
72
5A/40V
UTO Series | Connector
per IEC 61984
Ø 26.8
Female Female
1.6
23.0 25.5 maxi
25.2 maxi
23.0
24.1
Front
.5
mounting 25
Ø 21.5
Female Rear
17.9
30.2 mounting
33 maxi 23.0 Ø 25
34.0 24.7
Short version - 52.1 Short version - 53.1
Ø 22.5
Ø 27.0
27.4
52.0
Short version - 65.1 Short version - 65.1 67.7
36.5
73
UTO Series | Connector
Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Handle Head Complete set
Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT014DC
74
5A/40V
UTO Series | Connector
per IEC 61984
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132
19
UL 12
5A 40V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
75
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 9.5/14 UT016JCS UT016JC
76
9A/150V
UTO Series | Connector
per IEC 61984
Ø 30.0
Female Female
1.6
24.6 25.5 maxi
25.2 maxi
24.6
27.2
Front
mounting .3
28
Ø 24.6
Female Rear
17.9
33.3 mounting
33 maxi 24.6 Ø 28.1
34.0 27
Short version - 63.1 Short version - 69.1
Ø 25.8
Ø 30.0
29.4
55.0
Short version - 73.1 Short version - 83.1 73.1
39.5
77
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT016DC
78
9A/150V
UTO Series | Connector
per IEC 61984
19
PCB
UL 28
Wires used:
1.31mm² 10
IEC 5
9A 150V 2.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
79
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 9.5/14 UT018JCS UT018JC
80
8A/150V
UTO Series | Connector
per IEC 61984
Ø 33.3
Female Female
1.6
26.9 25.5 maxi
25.2 maxi
23
Ø 28.4
26.9
30.3
Front
mounting .8
31
Ø 27.8
Female Rear
17.9
36.5 mounting
33 maxi 26.9 Ø 31.3
31.4 27
Short version - 66.1 Short version - 72.1
Ø 33.3
Ø 33.3
35.2
60.0
Short version - 76.1 Short version - 86.1 77.2
46.0
81
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT018DC
82
8A/150V
UTO Series | Connector
per IEC 61984
UL 28
25
8A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
7A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
8A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
83
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 9.5/14 UT016JCS UT016JC
84
4A/40V
UTO Series | Connector
per IEC 61984
Ø 30.0
Female Female
1.6
24.6 25.5 maxi
25.2 maxi
24.6
27.2
Front
mounting .3 26
28
Ø 24.6
Female Rear
17.9
33.3 mounting
33 maxi 24.6 Ø 28.1
34.0 27
Short version - 63.1 Short version - 69.1
Ø 25.8
Ø 30.0
29.4
55.0
Short version - 73.1 Short version - 83.1 73.1
39.5
85
UTO Series | Connector
Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Handle Head Complete set
Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT016DC
86
4A/40V
UTO Series | Connector
per IEC 61984
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132
26
UL 9
Test 7
conditions 6
CSA 5
Contact used:
3A 250V UL94 V-0 Machined contacts 4
Wires used: 3
0.518mm²
IEC 2
1
4A 40V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
87
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT020JCS UT020JC
88
7A/150V
UTO Series | Connector
per IEC 61984
Ø 36.5
Female Female
2.4
29.3 27.5 maxi
29 maxi
29.3
33.5
Front
mounting .8
34
Ø 30.9
Female Rear
22.7
39.7 mounting 28
39 maxi 29.3 Ø 34.5
32.0 27
Short version - 74.8 Short version - 81.8
Ø 32.5
Ø 36.5
35.2
58.0
Short version - 88.3 Short version - 97.3 84.6
47.0
89
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT028DC
90
7A/150V
UTO Series | Connector
per IEC 61984
UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
7A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
91
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT020JCS UT020JC
92
7A/150V
UTO Series | Connector
per IEC 61984
Ø 36.5
Female Female
2.4
29.3 27.5 maxi
29 maxi
29.3
33.5
Front
mounting .8
34
Ø 30.9
Female Rear
22.7
39.7 mounting
39 maxi 29.3 Ø 34.5
30
Backshells (for Mated Connector Length: See Page 153)
32.0 27
Short version - 74.8 Short version - 81.8
Ø 32.5
Ø 36.5
35.2
58.0
Short version - 88.3 Short version - 97.3 84.6
47.0
93
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT028DC
94
7A/150V
UTO Series | Connector
per IEC 61984
UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
7A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
95
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 9.5/14 UT018JCS UT018JC
96
4A/50V
UTO Series | Connector
per IEC 61984
Ø 33.3
Female Female
1.6
26.9 25.5 maxi
25.2 maxi
26.9
30.3
Front
mounting .8
31
Ø 27.8
Female Rear
17.9
36.5 mounting
33 maxi 26.9 Ø 31.3
31.4 27
Short version - 66.1 Short version - 72.1
Ø 33.3
Ø 33.3
35.2
60.0
Short version - 76.1 Short version - 86.1 77.2
46.0
97
UTO Series | Connector
Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Handle Head Complete set
Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT018DC
98
4A/50V
UTO Series | Connector
per IEC 61984
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132
32
UL
4A 250V UL94 V-0 8
Test
conditions 6
CSA
Contact used:
3A 250V UL94 V-0 Machined contacts
4
Wires used:
0.518mm²
IEC 2
4A 50V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
99
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT022JCS UT022JC
100
6A/150V
UTO Series | Connector
per IEC 61984
39.5
Female Female
2.4
31.7 27.5 maxi
29 maxi
31.7
36.7
Front
mounting .9
37
Ø 34.1
Female Rear
22.7
42.9 mounting
39 maxi 31.7 Ø 37.7
Ø 39.7
41.1
58.0
Short version - 90.6 Short version - 99.6 91.7
48.0
101
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT022DC
102
6A/150V
UTO Series | Connector
per IEC 61984
35
UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
6A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
103
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT022JCS UT022JC
104
6A/150V
UTO Series | Connector
per IEC 61984
39.5
Female Female
2.4
31.7 27.5 maxi
29 maxi
31.7
36.7
Front
mounting .9
37
Ø 34.1
Female Rear
22.7
42.9 mounting
39 maxi 31.7 Ø 37.7
31.0 27
Short version - 77.1 Short version - 84.1
38
Ø 35.7
Ø 39.7
41.1
58.0
Short version - 90.6 Short version - 99.6 91.7
48.0
105
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT022DC
106
6A/150V
UTO Series | Connector
per IEC 61984
38
UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
6A 150V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
107
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT020JCS UT020JC
108
8A/80V
UTO Series | Connector
per IEC 61984
Ø 36.5
Female Female
2.4
29.3 27.5 maxi
29 maxi
29.3
33.5
Front
mounting .8
34
Ø 30.9
Female Rear
22.7
39.7 mounting
39 maxi 29.3 Ø 34.5
32.0 27
Short version - 74.8 Short version - 81.8
Ø 32.5
Ø 36.5
35.2
41
Long version - 84.6 Long version - 91.6
Fig. 1 Fig. 2 Fig. 5 Fig. 6
58.0
Short version - 88.3 Short version - 97.3 84.6
47.0
109
UTO Series | Connector
Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Handle Head Complete set
Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT020DC
110
8A/80V
UTO Series | Connector
per IEC 61984
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132
41
Electrical Characteristics UTO 2041 Derating Curves
Current (A)
10
UL 9
Test 7
conditions 6
CSA 5
Contact used:
2A 250V UL94 V-0 Machined contacts 4
Wires used: 3
0.518mm²
IEC 2
1
8A 80V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
111
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT024JCS UT024JC
112
6A/160V
UTO Series | Connector
per IEC 61984
Ø 42.6
Female Female
2.4
34.9 27.5 maxi
29 maxi
34.9
39.9
Front
mounting .2
41
Ø 37.3
Female Rear
23.6 mounting
46.0 34.9
41 maxi Ø 40.9
31.0 27
Short version - 82.4 Short version - 89.4
Ø 38.8
Ø 42.9
42.4
113
UTO Series | Connector
+ =
Handle Head Complete set
* For dustcap without chain, skip "G", e.g. UT024DC
114
6A/160V
UTO Series | Connector
per IEC 61984
UL 28
25
5A 500V UL94 V-0 23
Test 20
conditions 18
CSA 15
Contact used:
3A 500V UL94 V-0 Machined contacts
13
10
Wires used:
1.31mm² 8
IEC 5
6A 160V 2.5kV 3 3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
115
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT022JCS UT022JC
116
3A/80V
UTO Series | Connector
per IEC 61984
39.5
Female Female
2.4
31.7 27.5 maxi
29 maxi
31.7
36.7
Front
mounting .9
37
Ø 34.1
Female Rear
22.7
42.9 mounting
39 maxi 31.7 Ø 37.7
31.0 27
Short version - 77.1 Short version - 84.1
Ø 35.7
Ø 39.7
41.1
58.0
Short version - 90.6 Short version - 99.6 91.7 55
48.0
117
UTO Series | Connector
Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Handle Head Complete set
Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT024DC
118
3A/80V
UTO Series | Connector
per IEC 61984
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132
UL 9
conditions 6
CSA 5
Contact used:
2A 250V UL94 V-0 Machined contacts 4
Wires used: 3
0.518mm²
IEC 2
1
3A 80V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
119
UTO Series | Connector
Layout
OR OR OR OR
WITH
Part number*
Contact type Connector type Sealing Salt spray
Male insert Female insert
Backshells
Cable range Part number
Backshell type Shielding
(Ø mm) min/max Short version Long version
Short cable gland with strain relief nut
for water protected applications (IP68 & IP69K) (Fig.1)
- 11.5/18 UT024JCS UT024JC
120
3A/80V
UTO Series | Connector
per IEC 61984
Ø 42.6
Female Female
2.4
34.9 27.5 maxi
29 maxi
34.9
39.9
Front
mounting .2
41
Ø 37.3
Female Rear
23.6 mounting
46.0 34.9
41 maxi Ø 40.9
31.0 27
Short version - 82.4 Short version - 89.4
Ø 38.8
Ø 42.9
42.4
67.0
Short version - 95.9 Short version - 104.9 91.7
61
54.5
121
UTO Series | Connector
Part number
Contacts Contact size
of head
RM/RC 24W3K(1) S20RCM*
RM/RC 20W3K(1) Standard contacts S20RCM*
RM/RC 18W3K(1) #20
S20RCM*
SM/SC 24WL3(1)(2) Ø 1mm S20SCM20*
SM/SC 20WL3(1)(2) S20SCM20*
(1): Example of plating, for other plating options see page 129
(2): loose contact
* Heads to be used with handle PN: SHANDLES
+ =
Handle Head Complete set
Part number
RX20D44
* For dustcap without chain, skip "G", e.g. UT024DC
122
3A/80V
UTO Series | Connector
per IEC 61984
(1): Example of plating, for other plating options see page 129 Note: all dimensions are in mm
(2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6
(3): For dimensions see page 132
UL 9
Test 7
conditions 6
CSA
2A 250V UL94 V-0 Contact used:
5
4
61
Machined contacts
Wires used: 3
0.518mm²
IEC 2
1
3A 80V 1.5kV 3 0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
Current use Limited use Not recommended use
123
UTO SERIES
Contacts
Description ................................................................................................................ 126
125
UTO Series | Contacts
Contacts
Description
The UTO series is delivered without contacts and offers the unique feature to use the same style contact in any layout with the same active part
size (i.e. #20, #16, #12, etc.). This provides our customers with an easy solution to buy only one type of contact to equip all their connectors
even if housings/shell sizes are different.
This provides the benefit of standardization and subsequent reduced inventory costs. In addition, it eliminates the need for added tooling and
simplifies the assembly process. Souriau contacts are designed for simple snap-in installation and further eliminate the need for insertion
tooling.
In addition to the below “crimp” style contact options, the UTO series can also be equipped with PCB contacts.
126
UTO Series | Contacts
Once the contact size has been selected, the next step is to decide on which type to use. Souriau offers two main types of electrical contacts:
• Machined
• Stamped & Formed
Machined contacts are generally chosen as a better solution for power applications or when lower quantities are needed.
Stamped & formed contacts offer the ability to be crimped automatically which makes them more suitable for high volume production
applications.
The graph below can help guide you to plating recommendations based on application, mating cycles and current/voltage needs.
Note: do not mix different plating (i.e. tin plated pin contacts with gold plated socket contacts).
Number of
Vibration cycles
250
Gold flash
0.4μm of gold
Contacts
Silver
min
100
Tin
Current /
1Amp
5mV Voltage
127
UTO Series | Contacts
Packaging
Due to the wide variety of applications, contact packaging is offered for small series (bulk package) and high volume production (reeled contacts):
• 25 pieces loose package • 50 pieces bulk package • 1,000 pieces • 3,000 pieces reeled • 2,000 pieces reeled
(stamped & formed (machined contacts) bulk package (stamped & formed (machined contacts)
contacts) (machined contacts) contacts) Size #16 only
Note: 1,000 pieces bulk package available by adding 1000 at the end of the part number: e.g. RC16M23K1000
2,000 pieces reeled package available by adding K at the beginning of the part number: e.g. KRC16M23K
128
UTO Series | Contacts
Crimp Contacts
Standard Version
Contacts
Formed SM20ML1-(2) SC20ML1-(2) grip
Ø1.6
mm Machined 20-16 0.52-1.5 RM16M23- RC16M23- 1.8 3.2 K, J
Stamped & SM16M1-(1) SC16M1-(1) No insulation
18-16 0.8-1.5 3.0 S31, S18, TK6
Formed SM16ML1-(2) SC16ML1-(2) grip
Stamped & SM16M11-(1) SC16M11-(1) Insulation
18-16 0.8-1.5 2.0-3.0 S31, S18, TK6
Formed SM16ML11-(2) SC16ML11-(2) grip
Machined 16-14 1.5-2.5 RM14M30- RC14M30- 2.28 3.2 K, J
Stamped & SM14M1- (1)
SC14M1- (1)
No insulation
14 2.0-2.5 3.2 S31, S18, TK6
Formed SM14ML1-(2) SC14ML1-(2) grip
22 0.13-0.4 82911457N- 82911456-
20 0.5 82911459N- 82911458-
#12 18 0.75-1.0 82911461N- 82911460-
Ø2.4 Machined - 4.9 A, K
mm 16 1.5 82911463N- 82911462-
14 2.5 82911465N- 82911464-
12 4 82911467N- 82911466-
16 1.5 82913601A 82913600A
#8
14 2.5 82913603A 82913602A
Ø3.6 Machined 12 4 82913605A 82913604A - 6.5 A
mm
10 6.0 82913607A 82913606A
8 10.0 82913609A 82913608A
(1) contact reeled (2) loose contact Note: all dimensions are in mm
Exemple: RM24W3K - Size #20, Machined, AWG24 wire.
129
UTO Series | Contacts
Contact 1
Standard male Standard female
Longer male contact
contact contact First Mate Last Break contacts should be
Contact 2
chosen only if the cavity is not marked with
the ground symbol. For cavities marked
with the ground symbol, standard contacts
Standard male
will fulfill the same role as a first mate, last
contact
break contact used in a standard cavity.
Standard female
contact
FMLB
Shorter female
contact Ground symbol
LMFB
130
UTO Series | Contacts
souriau provides 2 types of coaxial contacts suitable for 50 or 75Ω, coaxial cable or twisted pair cable.
• An outer ferrule is used to connect the braid to the outer contact and provide
cable support to ensure against bending and vibration.
Contacts
Inner conductor up to 2.44mm diameter Inner conductor from AWG30 to AWG24
Contact range
Contact part number with
Contact type Cabling notice
Male contact Female contact cable combination
RMDXK10D28 RCDXK1D28
Multipiece See page 170
+ YORK090 + YORK090 See page 169
Monocrimp RMDX60xxD28 RCDX60xxD28 See page 171
131
UTO Series | Contacts
PCB Contacts
PCB Contacts
PCB soldering
The UTO series can be used in a wave soldering process, but not reflow soldering process.
All high temperature processes are prohibited.
A A
A G G G
UTO0/UTOW0
UTO7/UTOW7 UTO7/UTOW7
UTO0 and UTOW0 Male insert Female insert
132
UTO Series | Contacts
Description
Size 16 fiber optic contacts for UTO and other TRIM TRIO® connectors
Size 16 fiber optic contacts are designed for the integration of optical links in UTO and other TRIM TRIO® cable connectors.
Technical Characteristics
Performance
• Fiber type:.........................................................................................................POF
• Wave length:................................................................................................... 650 nm
• Optical insertion loss (typ.):.......................................................................... 2 dB max.
• Jacketed external diameter:............................................................................2.2mm
• Temperature range:..................................................................................-25°C to +70°C
• Cable retention:.................................................................................................49N
• Mating cycles without cleaning:......................................................................... 50
• Max. mating cycles:........................................................................................... 500
Contacts
Construction
• Contact body: Copper alloy
Connector accommodation
Any TRIM TRIO® size 16 contact can be used in any contact position in any connector in the TRIM TRIO® size 16 interconnection system:
UTP, UTS, UTG, UTO.
133
UTO Series | Contacts
Ordering Information
STANDARD TOOLING KIT - P/N 80MS0004 SPECIFIC TOOLING LIST - Can only be ordered separately
The standard tooling kit is made of the part numbers below
that can be ordered separately as well.
80WD0025
Automatic stripping tool for Ø 0.5 mm, 80WG0015 Capsule
0.6 mm, 0.7 mm & 3.8 mm
80WG0016 Syringe
80WM0006 Ruler
80WN0005 Dry air spray
80WP0005 Polishing plate
80WN0006 Optical paper
80WP0013 Non slip base (to hold the polishing plate)
80WN0012 Dropper bottle
80WP0014 Polishing disk (grain size 9µm)
80WN0008 Wiping solvent
80WP0018 Polishing tool
80WP0019 Polishing disk (grain size 30µm)
80WS0002 Crimping plier
134
UTO Series | Contacts
Contacts
135
UTO SERIES
Technical Information
Tooling ..................................................................................................................... 139
137
UTO Series | Technical Information
Mecal is a leader in manufacturing tooling for The extreme environment interconnect specialist
crimping terminals over a stripped wire. “from deep sea to deep space”.
Established in 1976, Mecal has become one of the SOURIAU designs, manufactures and markets high
world's leading companies dedicated to the design performance interconnect solutions for severe
and manufacture of semi automatic production tools environments dedicated to the aerospace, defense,
for strip fed, open barrel crimp terminals, serving the light and heavy industry markets.
Automotive, Telecom and Datacom industries.
SOURIAU has been working in partnership with Mecal for many years. With sales offices located in all major
industrial regions of the world, the combined strengths of both organisations has resulted in a truly global
solution to all your production tooling needs.
138
UTO Series | Technical Information
Tooling
Standard contacts
Contact size Part number Head* Handles* Extraction tools
RM/RC 24W3K
RM/RC 20W3K S20RCM
#20 RM/RC 18W3K
Ø 1mm
RX20D44
SM 24WL3S*(1)
SC 24WL3S*(1) S20SCM20
SM/SC 20WL3S*(1)
RM/RC 28M1*
RM/RC 24M9*
S16RCM20
RM/RC 20M13* SHANDLES
RM/RC 20M12*
RM/RC 16M23* S16RCM16
#16
Ø 1.6mm
RM/RC 14M30* S16RCM14 RX2025GE1
SM/SC 24ML1*
S16SCM20
SM/SC 20ML1*
SM/SC 16ML1*
S16SCML1
SM/SC 14ML1*
SM/SC 16ML11* S16SCML11
(1) loose contact * Endurance of SHANDLES & Head tools = 50,000 cycles
Technical Information
* see page 129 for plating options and other contact details
Coaxial contacts
See coax contacts details on page 131 and cabling notice pages 170 to 174.
139
UTO Series | Technical Information
Crimping Instructions
L
SM16M1- / SM16ML1- SC16M1- / SC16ML1- 6.35
140
UTO Series | Technical Information
Crimping
One of the key factors which affects the performance of a connector is - No health risk from heavy metal and flux steam
the way contacts are terminated. Crimped connections are nowadays - Preservation of conductor flexibility behind the crimped
seen as the best solution to ensure quality throughout the lifetime of connection
the product. Here are some reasons why we recommend this method - No burnt, discolored and overheated wire insulation
of termination for UTO connectors: - Good connections with reproducible electrical and mechanical
performances
Advantages (Extract from the IEC 60352-2): - Easy production control.
- Efficient processing of connections at each production level
- Processing by fully-automatic or semi- automatic crimping To ensure that the crimp tooling is performing according to original
machines, or with hand operated tools specifications, it is important to carry out regular checks. A common
- No cold-soldered joints way to check the performance of tooling is with a simple pull test,
- No degradation of the spring characteristic of female contacts ideally using a dedicated electric pull tester. Minimum recommended
by the soldering temperature pull forces are indicated in the tables below:
H
Machined
contact
contact
W W
Technical Information
Machined RC20M13K* AWG 20 0.50 max 60 N
contacts size 22/20 1.26 1.76
#16 RM20M12K* AWG 22 0.32 min 40 N
Ø 1.6 mm RC20M12K* AWG 20 0.50 max 60 N
20 AWG 20 0.50 max 60 N 1.66 2.18
RM16M23K*
18 AWG 18 0.82 max 90 N 1.80 2.28 S16RCM16
RC16M23K*
16 AWG 16 1.50 max 150 N 1.96 2.43
RM14M30K* 16 AWG 16 1.50 min 150 N 2.10 2.68
S16RCM14
RC14M30K* 14 AWG 14 2.50 min 230 N 2.30 2.78
SM24ML1TK6* AWG 26 0.12 min 15 N
26/24 0.84 1.50
SC24ML1TK6* AWG 24 0.25 max 32 N
S16SCM20
SM20ML1TK6* AWG 22 0.32 min 40 N
22/20 1.02 1.54
S&F SC20ML1TK6* AWG 20 0.50 max 60 N
contacts size SM16ML11TK6* 18 AWG 18 0.75 min 90 N 1.32 2.09
S16SCML11
#16 SC16ML11TK6* 16 AWG 16 1.50 max 150 N 1.36 2.10
Ø 1.6 mm
SM16ML1TK6* 18 AWG 18 0.75 min 90 N 1.49 2.02
SC16ML1TK6* 16 AWG 16 1.50 max 150 N 1.7 2.05
S16SCML1
SM14ML1TK6*
14 AWG 14 2.50 max 230 N 1.79 2.58
SC14ML1TK6*
*: example of plating options, for other plating see page 129
141
UTO Series | Technical Information
User Guide
1) Fully close then release the tool, keep it open. 5) Place conductors, with no deteriorations, in the bucket
Open the 2 pins. contact. All strands to be located in the crimp bucket.
2) Choose the adapter head (sold separately), keep vertical and 6) Position the contact in the bottom of the tool by checking
slide it into the handle until the mechanical end. its orientation.
3) Close the two pins simultaneously to maintain the head. 7) To crimp contact assembly-cable, tighten sharply the clip
to the end of the mechanism.
142
UTO Series | Technical Information
Extraction Tools
RX2025GE1
Contact size Extractor
#20 RX20D44
#16 RX2025GE1 51060210936
#12 51060210924
#8 51060210936
RX20D44
51060210924
Technical Information
L
Shell UTO0 UTO7
L1 size L max L1 max L2 max L3 max L max L1 max L2 max L3 max
8 42.8 36.8 80.7 57.2 46.8 36.8 85.8 57.2
10 55.8 50.3 98.6 92 60.5 50.3 102.7 92
12 57.1 51.4 99.3 93.7 61.4 51.4 106.4 93.7
14 62.5 56.3 100.3 94.6 67.6 56.3 104.8 94.6
L2
L3
143
UTO Series | Technical Information
Assembly Instructions
• Strip wires and crimp contacts (see pages 140 & 141)
• Insert contacts into connector cavities (insert manually or use tool RTM205 crimp contacts)
• Place receptacle in the panel cut-out
• Secure receptacle with screws (not supplied)
Tighten screws: M2.5 for size connectors 10 to 22, M3 for size connectors 24
(recommended torque: see table below)
• For complete sealing of the system use optional gasket and sealed screw solution (not sold by Souriau).
Gasket (optional)
Gasket (optional)
Receptacle
flange
Panel thickness:
Panel 2.5mm max
Shell size
10 12 14 16 18 20 22 24
Screws tightening
0.30/0.40 0.30/0.40 0.30/0.40 0.30/0.40 0.35/0.45 0.50/0.60 0.55/0.65 0.55/0.65
torque (Nm)
144
UTO Series | Technical Information
• Strip wires and crimp contacts (see pages 140 & 141)
• Insert contacts into connector cavities (insert manually or use tool Panel thickness
RTM205 crimp contacts )
• Seat o-ring, place receptacle in the panel cut-out Jam nut
• Tighten jam nut
Technical Information
145
UTO Series | Technical Information
Ferrule
UTO6
UTO7
• Slide accessories onto the cable gland body to adapter and tighten (recommended torque:
• Strip external cable jacket (see dimension H in the table below) see table below)
• Strip wires and crimp contacts (see pages 140 & 141) • Mate the plug with the receptacle to make the following step easier
• Insert contacts into connector cavities (insert manually or use tool • Slide ferrule inside the cable gland body as shown in fig. A
RTM205) • Tighten backshell nut with cable gland body as shown in fig. B
• Screw adapter to the rear of the connector body and screw cable (recommended torque: see below).
fig. A fig. B
Spanner size
JCS/JC JSCL/JCL
Shell size
Cable gland body Backshell nut Cable gland body Backshell nut
10 17 mm 14 mm 17 mm 17 mm
12 & 14 22 mm 20 mm 22 mm 22 mm
16 & 18 26 mm 24 mm 30 mm 30 mm
20, 22 & 24 33 mm 30 mm 40 mm 40 mm
146
UTO Series | Technical Information
•
UTO0 or UTO7 with UTO6 + JCS or JC or JCSL or JCL for Shielded Cable
Shielding ferrule
UTO6
UTO7
• Slide accessories onto the cable gland body to adapter and tighten (recommended torque:
• Strip external cable jacket (see dimension H and L in the table below) see table below)
• Strip wires and crimp contacts (see pages 140 & 141) • Mate the plug with the receptacle to make the following step easier
• Insert contacts into connector cavities (insert manually or use tool • Slide ferrule inside the cable gland body as shown in fig. A
RTM205) • Tighten backshell nut with cable gland body as shown in fig. B
• Screw adapter to the rear of the connector body and screw cable (recommended torque: see below).
fig. A fig. B
Technical Information
(Nm) (Nm) (Nm) Male Female Male Female
10 6 6 5 50 58 61 68 8
12 10 10 8 54 61 65 73 12
14 10 10 8 59 66 73 80 12
16 14 14 12 68 75 79 86 12
18 14 14 12 72 80 83 91 12
20 24 24 20 80 89 90 98 14
22 24 24 20 83 91 94 102 14
24 24 24 20 88 96 98 106 14
* Indicative torque, needs to be adjusted depending on the cable used
Spanner size
JCS/JC JSCL/JCL
Shell size
Cable gland body Backshell nut Cable gland body Backshell nut
10 17 mm 14 mm 17 mm 17 mm
12 & 14 22 mm 20 mm 22 mm 22 mm
16 & 18 26 mm 24 mm 30 mm 30 mm
20, 22 & 24 33 mm 30 mm 40 mm 40 mm
147
UTO Series | Technical Information
UTO0
Modular
gasket
Cable clamp
UTO6
UTO7
• Slide accessories onto the cable • Tighten backshell with plug and mate plug with a receptacle
• Strip external cable jacket (recommended torque values to be applied according to the
• Strip wires and crimp contacts (see pages 140 & 141) table below)
• Insert contacts into connector cavities (insert manually or use tool • Tighten backshell screws.
RTM205)
Clamp (mm)
Shell size Cable clamp tightening torque (Nm)
Min Max
10 4 1.5 5.0
12 5 3.0 8.2
14 5 4.0 10.0
16 9 6.0 13.0
18 9 8.5 16.0
20 11 10.0 16.0
22 13 9.0 19.3
24 15 11.0 20.6
148
UTO Series | Technical Information
UTO0
Right angle
cable clamp
UTO6
UTO7
• Remove inner part of the modular gasket to adjust the internal • Tighten backshell with plug and mate plug with a receptacle
diameter to fit the cable (see table) (recommended torque values to be applied according to the
• Slide accessories onto the cable table below)
• Strip external cable jacket • Tighten backshell screws.
• Strip wires and crimp contacts (see pages 140 & 141)
Technical Information
14 10 7.5 10 13 -
16 14 7.5 11 13.5 16
18 14 10 13.5 17 20
20 24 10 13.5 17 20
22 24 10 13.5 17 20
24 24 18 22 25.5 29
Ø Cable range
A
B
C
D
149
UTO Series | Technical Information
UTO6 Modular
PG-tube gasket
Inner shielding adapter
ferrule
UTO7
• Mate UTO6 (plug) with UTO0 or UTO7 already mounted on a • Place cable braid shield over inner shielding ferrule (See fig. A)
panel and slide the outer ferrule over the braid shield for UTOS-JCPGN
• Slide accessories onto the cable • Screw PG-tube adapter with plug (recommended torque:
• Strip external cable jacket (see dimension H and L) see below table)
• Strip wires and crimp contacts (see pages 140 & 141) • Tighten PG-nut with PG-tube adapter (See fig. B)
• Insert contacts into connector cavities (insert manually or use • Tighten PG-nut screws.
RTM205 tool)
UTOS-JCPGN
fig. A fig. B
150
UTO Series | Technical Information
UTO6
Nut
Grommet +
compression ring
UTO7
• Strip wires and crimp contacts (see pages 140 & 141) • Insert the other contacts
• Insert first contact into the grommet (first contact in cavity A, • Tighten the nut to rear of either UTO7 or UTO6 (recommended
no tool is required). Then insert the contact in the connector torque values to be applied according to the table below).
cavity A (insert manually or use tool RTM205)
Technical Information
151
UTO Series | Technical Information
Nut
UTO6
Adapter + mounted gasket
Cable range
Grommet +
compression ring
Reducing Standard
UTO7
Cable ranges
• Strip wires and crimp contacts (see pages 140 & 141) • Tighten adapter with plug, choose right seal (waste the other
• Insert first contact into the grommet (first contact in cavity A, seal)
no tool is required). Then insert the contact in the connector • Tighten the nut to rear of either UTO7 or UTO6 (recommended
cavity A (insert manually or use tool RTM205) torque values to be applied according to the table below).
• Insert the other contacts
152
UTO Series | Technical Information
B D
Technical Information
F L
UTO7 + UTO6 + UTO with UTO7 + UTO6 + UTOS with
JCS or JC or JCSL or JCL JCS or JC or JCSL or JCL
UTO0 + UTO6 + UTO with UTO7+ UTO6 + UTO with UTO0 + UTO6 + UTOS with UTO7+ UTO6 + UTOS with
Shell size JCS JC JCSL JCL JCS JC JCSL JCL JCS JC JCSL JCL JCS JC JCSL JCL
E max E max E max E max F max F max F max F max H max H max H max H max L max L max L max L max
10 68.1 80.1 68.1 80.1 72.8 84.8 72.8 84.8 78.1 90.1 79.1 91.1 82.8 94.8 83.8 95.8
12 68.1 81.1 69.1 82.1 72.8 85.8 73.8 86.8 81.1 94.1 81.1 94.1 85.8 98.8 85.8 98.8
14 73.1 87.1 74.1 88.1 77.8 91.8 78.8 92.8 86.1 100.1 86.1 100.1 90.8 104.8 90.8 104.5
16 82.1 93.1 88.1 99.1 86.8 97.8 92.8 103.8 92.1 103.1 102.1 113.1 96.8 107.8 106.8 117.8
18 85.1 95.6 91.1 101.6 89.8 100.3 95.8 106.3 95.1 105.6 105.1 115.6 99.8 110.3 109.8 120.3
20 98.4 108.2 105.4 115.2 103.9 113.7 110.9 120.7 111.9 121.7 120.9 130.7 117.4 127.2 126.4 136.2
22 100.7 112.0 107.7 119.0 106.2 117.5 113.2 124.5 114.2 125.5 123.2 134.5 119.7 131.0 128.7 140.0
24 106.9 116.9 113.9 123.9 112.4 122.4 119.4 129.4 120.4 130.4 129.4 139.4 125.9 135.9 134.9 144.9
Note: all dimensions are in mm
153
UTO Series | Technical Information
154
UTO Series | Technical Information
The current carrying capacity of a connector is limited by the thermal properties of materials used in its construction. The amount of current that
can be handled depends on the size of cable used, the ambient temperature and the heat that is generated inside the connector. Part 3 of the
IEC 60512 standard determines through a derating curve, the maximum current permissible, which varies from one layout to another (Fig.1 &
Fig.2). Wire size plays an important role in dissipating heat and avoid overheating (Fig.1 & Fig.3).
Please note that the curve should be adjusted when dealing with potential hot spots, which can occur as a result of unequal loading of current
across a number of contacts. As a general rule, it is best to avoid placing power handling contacts in the middle of the connector; try to locate
them towards the edge where heat can be dissipated more effectively. Eventually you should find a level which represents the permissible ope-
rating range:
Fig.1: UTO 12-4 – 1.5mm² wires Fig.2: UTO 12-8 – 1.5mm² wires
30 30
28 28
25 25
23 23
Current (A)
20 20
Current (A)
18 18
15 15
13 13
10 10
8 8
5 5
3 3
0 0
0 20 40 60 80 100 120 0 20 40 60 80 100 120
Ambient Operating Temperature (°C) Ambient Operating Temperature (°C)
20
Technical Information
18
15
Limited use
13
10 Not recommended use
8
5
3
0
0 20 40 60 80 100 120
Ambient Operating Temperature (°C)
The rated current is defined as uninterrupted continuous current that a connector can take when all contacts are energized simultaneously
without exceeding the maximum limit of temperature. The earth contact is never loaded.
155
UTO Series | Technical Information
Shielding Effectiveness/Corrosion
Shielding Effectiveness
(dB)=10Log Pin
Pout
Pin: Power in
Pout: Power out
Corrosion Resistance
Outdoor application
maintaining mechanical and electrical functionality.
4 Corrosive Gases)
Indoor application
156
UTO Series | Technical Information
UL94 + UL1977
Underwriter Laboratories
There are two main standards for industrial connectors: UL94 & UL1977
UL94
This standard is dedicated to plastics flammability. It characterises how the material burns in various orientation and thicknesses.
Procedure: A specimen is supported in a vertical or horizontal position and a flame is applied to the bottom of the specimen. The flame is applied
for ten seconds and then removed until flaming stops, at which time the flame is reapplied for another ten seconds and then removed. Two sets
of five specimens are tested.
13±0.5mm
Material
• Total flaming combustion time must not exceed 50 seconds
for each set of 5 specimens 125±1mm
• Specimens must not burn with flaming or glowing combustion
up to the specimen holding clamp
• Specimens must not drip flaming particles that ignite
the cotton
• No specimen can have glowing combustion remain for longer
than 30 seconds after removal of the test flame.
45°
300±1mm
~
~
Cotton
157
UTO Series | Technical Information
Underwriter Laboratories
UL1977
There are several standards which deal with plug and receptacle. Each of them is only for a small area of applications. It could be
telecommunication, etc. The UL 1977 covers single and multipole connectors intended for factory assembly.
Requirements apply to devices taking into account intensity and voltage. The categories are as follows:
30 V
0 (42 V peak) 600 V
Type 0 Type 1A
8.3 A
Type 2
31 A Tybe 1B
Type 3
200 A
Type 4
1000 A
According to above table, the level of performance that has to be reached could be different. Most of them are explained in the following page.
Insulating materials:
Material uses for electrical insulation, as a minimum, have to comply with the characteristics shown below:
Assembly:
Connector has to be keyed to prevent any mismating that can damage the machine or hurt the user. In the same way, plugs and sockets have to
be equipped to protect persons against contact with live parts.
Finally the identified grounding contact shall be located so that the corresponding electrical continuity has to be completed before any other
contact.
158
UTO Series | Technical Information
Underwriter Laboratories
UL1977
Spacing:
For a 250V max connector, distance through air or over material shall be 1.2mm whereas from 250V to 600V connector the spacing is 3.2mm
minimum. These distances have to be taken between uninsulated live parts as shown in the matrix below:
Uninsulated live part - uninsulated Uninsulated live part - uninsulated Uninsulated live part - exposed dead
Type
live part of opposite polarity grounded metal part metal part
0 No No No
1A Yes Yes Yes
1B Yes Yes No
2 Yes Yes Yes
3 Yes Yes Yes
4 Yes Yes Yes
An alternative way to determine voltage rating is with the Dielectric-Withstand test. If during one minute there is no arc-over or breakdown the
rated voltage is given as shown below:
Marking:
A device shall be legibly marked with the manufacturer's trade name, trade mark, or other descriptive marking by which the organisation
responsible for the product may be identified. (Exception: If the device is too small, or where the legibility would be difficult to attain, the
manufacturer’s name, trademark, or other descriptive marking may appear on the smallest unit container or carton)
The following shall be marked on the device or on the smallest unit container or carton or on a stuffer sheet in the smallest unit container or
carton:
Technical Information
b) The electrical rating in both volts and amperes, if assigned
c) Whether ac or dc, if restricted
d) Flammability class, if identified
Example - Marking for the arrangement 10-3: 10A 500V UL94 V-0
159
UTO Series | Technical Information
IEC 61984
The norm is dedicated to connectors with rated voltage above 50V and up to 1000V and rated currents up to 125A per contact.
Depending on your application connectors should be compliant with another standard. This has to be double checked with the customer.
There are a lot of constructional requirements and performances specified in that standard. Most of them are illustrated in greater details hereafter.
First digit
IP Code: (foreign bodies
IP is a coding system defined by the IEC 60529 to indicate the protection)
degrees of protection provided by an enclosure. The aim of this is to
give information regarding the accessibility of live parts against ingress
of water and other foreign bodies. Code letters Second digit
(international IP 6 8 (water
Protection) protection)
160
UTO Series | Technical Information
IEC 61984
Overvoltage
UTO connectors are qualified to be used on systems rated at Overvoltage category III
Per the IEC 60664-1 (formely VDE 0110) each category is linked to the end application and where the device will be implemented:
Pollution degree
Per the IEC 60664-1 (formerly VDE 0110) the environment affects the performance of the insulation. Particles can build a bridge between
two metal parts. As a rule dust mixed with water can be conductive and more generally speaking metal dust is conductive. Finally, the
standard defines 4 levels of pollution:
Technical Information
Finally, the harsher the environment is, the longer clearance and creepage distances should be. Nonetheless, according the IEC 61984,
enclosure rated at IP54 or higher can be dimensioned for a lower pollution degree. This applies to mated connectors disengaged for test and
maintenance.
Marking
The marking should give enough details to the user to know what the main characteristics are and without going deep in technical
documentation. Below examples identify the suitability of the connector:
• Example 1:
Marking of a connector with rated current 16A, rated voltage 400V, rated impulse voltage 6kV and pollution degree 3, 2 and 1 for
use in any system, preferably unearthed or delta-earthed systems:
16A
16A 400V
400V 6kV
6kV 33
• Example 2:
Marking of a connector with rated current 16A, rated insulation voltages line-to-earth 250V, line-to-line 400V, rated impulse
voltage 4kV and pollution degree 3, 2 and 1 for use in earthed systems:
16A250V
16A 250V400V
400V4kV
4kV3 3
161
UTO Series | Technical Information
IEC 61140
On a daily basis, we are using many electrical appliances, some are grounded, and some are not. The levels of grounding protection are clearly
defined by the International Electrotechnical Commission standard IEC 61140, a standard that has an influence on our connectors and how
they should be used; our customers therefore need to pay particular attention to the three categories defined within this standard to ensure
compatibility with their system. Everything explained hereafter is valid for connectors not intended to interrupt current.
Class I:
Devices which belong to this category have their chassis grounded via the ground wire (green/yellow in Europe, green in the US, Canada and
Japan). A fault in the appliance might cause a live conductor to energize the casing. In this case, the current flows to the ground conductor and
the circuit interrupter will cut off the power supply. In case of the UTO series, it means the envelope (coupling ring, backshell and housing) may
become live, therefore, care needs to be taken to attach the connector to the ground. This is usually done via the ground conductor using a splice
between the ground contact and the housing.
Class II:
Products in this category have reinforced insulation, meaning that the casing does not need to be connected to ground. In this case, the possibility
of electric shock has been removed. Most of the time, reinforced insulation means double insulation, i.e. the second layer will take over the first
one in case the first one fails. The UTO series is not designed to comply with this standard, so we cannot recommend it for this product category.
Note: UL 1310 also defines a class II device, but in that case this is just to set the upper limit of use, like a wall charger for our cell phone.
Class III:
In this category, electrical appliances are fed by a low voltage source (<48VAC or < 120VDC). In normal conditions live conductors can be
accessible without any risk for the end user. No particular attention needs to be taken in regards to UTO series when it comes to a class III device.
Conclusion :
UTO series can be used in class I and class III environments, but each category affects the product performance. Throughout the catalog, current
and voltage ratings have been given for class I devices keeping in mind the ground conductor needs to be attached according to recommended
wiring instructions.
Note: Special applications like recreational vehicles are not under the scope of the IEC 61140.
162
UTO Series | Technical Information
The correlation between NEMA & IP being limited only to dust and water, we can state that a NEMA type is equivalent to an IP rating but it is not
possible to say the contrary.
Enclosure
IP20 IP22 IP55 IP64 IP65 IP66 IP67 IP68
rating
Type 1 •
Type 3 •
Type 3R •
Type 3S •
Type 4 •
Type 4X •
Type 6 •
Type 6P •
Type 12 •
Type 13 •
• indicates compliance
6 IP67 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with the enclosed equipment, falling dirt, hose-directed water, the entry of water during occasional temporary
submersion at a limited depth and damage from external ice formation.
6P IP68 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with the enclosed equipment, falling dirt, hose-directed water, the entry of water during prolonged submersion at
Technical Information
a limited depth and damage from external ice formation.
163
UTO Series | Technical Information
Ethernet Basics
Ethernet is a widely used communications protocol that is used to transmit data packets (datagrams) between network devices. Imagine a highway in a
large metropolitan area six lanes wide at rush hour. The vehicles on the highway need rules to follow so that they get to their destination without crashing
into each other. In an Ethernet network link, there could be 100 million bits of information transmitted in one second. In the Ethernet standard, there exist
rules to govern packet structure, transmission requirements, error correction, communication with end equipment, etc.
In connectors and cables, Fast Ethernet uses 2 pairs. One for transmit and one for receive. This way data traffic can flow in both directions simultaneously.
164
UTO Series | Technical Information
Souriau offering:
Standard solutions.
UTO size 10, 6 contacts - Cat5e UTO size 12, 10 contacts - Cat5e UTO size 16, 19 contacts -Cat5e
Twisted pairs Twisted pairs Twisted pairs (1Gb/s)
1 (Pair 1) Ã A
2 (Pair 1) Ã B
104
4 Ø 1.6 (#16)
Technical Information
cannot be offered, they are too thin and often solid (not stranded).
In the rest of industry, UTP (Unshielded Twisted Pairs) cables are widely used. The Quadrax contact is not designed to terminate them. And thus, are not
advised for industrial applications.
Conclusion
To carry 100Mb/s data signal, 100BaseTX or Fast Ethernet recommends the use of Cat5e connectors as well as Cat5e cable with the support of a 100MHz
signal. Nevertheless, a 100Mb/s signal can be transmitted in certain conditions (short distance, only one connector, lower frequency but a different code)
thru many other connection materials - not necessarily Cat5e rated.
165
UTO SERIES
Appendices
#16 Coaxial Contacts/Cabling Notices ................................................................... 168
167
UTO Series | Appendices
Inner
Ø over Ø over
cond Ø outer braid
jacket dielectric
Cable Impe- Contact size Male contact kit Female contact kit
type dance type Ext. for coaxial cable for coaxial cable
inch mm inch mm Ø inch mm
mm
RG161/U 75 0.09" 2.29 0.057" 1.45 - - -
RG179A/U 75 0.105" 2.67 0.063" 1.6 0.3 0.084" 2.13 max
RG179B/U 75 0.105" 2.67 0.063" 1.6 0.3 0.084" 2.13 max
RG187/U 75 0.11" 2.79 max 0.06" 1.52 0.3
Multi
RG188/U 50
piece
0.11" 2.79 max 0.06" 1.52 0.51 0.078" 1.98 max RMDXK10D28 RCDXK1D28
RG174/U 50 0.11" 2.92 0.06" 1.52 0.48 0.088" 2.24 max
AMPHENOL 21-598 50 0.105" 2.67 0.06" 1.52 0.48 - -
RG196/U 50 0.08" 2.03 max 0.034" 0.086 0.3 - --
RG178A/U 50 0.075" 1.91 0.034" 0.86 0.3 0.054" 1.37 max
RG/188A/U 50 0.110" 2.79 0.06" 1.52 0.51 0.078" 1.98 max RMDX6036D28 RCDX6036D28
KX21TVT (europe)
RG178 B/U
50 0.075" 1.91 0.034" 0.86 0.3 0.054" 1.37 max RMDX6034D28 RCDX6034D28
RG178 / BU 50 0.075" 1.91 0.034" 0.86 0.3 0.054" 1.37 max RMDX6050D28 RCDX6016D28
RG174/U 50 Mono 0.115" 2.92 0.06" 1.52 0.48 0.088" 2.24 max RMDX6032D28 RCDX6032D28
crimp
RG188A/U 50 0.11" 2.79 0.06" 1.52 0.51 0.078" 1.98 max RMDX6036D28 RCDX6036D28
RG316/U 50 0.107" 2.72 0.06" 1.52 0.51 0.078" 2.05 max RMDX6036D28 RCDX6036D28
raychem 5024A3111 50 0.12" 3.05 0.083" 2.11 0.64 0.097" 2.46 RMDX6052D28 RCDX6052D28
raychem 5026e1614 50 0.083" 2.11 0.05" 1.27 0.48 0.067" 1.7 RMDX6036D28 RCDX6036D28
Multi
surprenant pn 8134 -
piece
0.1" 2.54 0.058" 1.47 0.3 - - RMDXK10D28 RCDXK1D28
PRD PN 247AS-
C1123-001
- 0.103" 2.62 0.06" 1.52 0.51 0.078" 1.98 RMDX6018D28 RCDX6018D28
PRD PN 247AS-C1251 - 0.092" 2.34 0.05" 1.27 0.64 0.067" 1.7 RMDX6018D28 RCDX6018D28
JUDD C15013010902 - 0.087" 2.13 0.05" 1.27 0.48 0.066" 1.67 RMDX6036D28 RCDX6036D28
CDC PIN22939200 - 0.09" 2.29 0.048" 1.22 0.3 0.064" 1.63 RMDX6046D28 RCDX6016D28
CDC PIN22939200 - 0.09" 2.29 0.048" 1.22 0.3 0.064" 1.63 RMDX6050D28 RCDX6016D28
CDC PIN245670000 - 0.104" 2.64 0.067" 1.7 0.3 0.083" 2.11 RMDX6050D28 RCDX6016D28
ampex - Mono 0.114" 2.9 0.075" 1.91 0.38 0.09" 1.29 RMDX6032D28 RCDX6032D28
TI PN 920580 - crimp 0.7" 1.78 0.038" 0.96 0.48 0.054v 1.37 RMDX6024D28 RCDX6024D28
0.41
Honeywell PN 58000062 - 0.12" 3.05 0.077" 1.96
solid
0.096" 2.44 RMDX6026D28 RCDX6026D28
168
UTO Series | Appendices
Ø over
Ø outer
jacket Inner cond size
Inner braid Male Female
Cable Contact (single wire)
AWG contact kit for contact kit for
type type
cond coaxial cable coaxial cable
Stranded Ext. Ø
inch mm inch mm
definition mm
1.24
2#24 stranded mil-w-16878 type B 24 0.049"
max
7/.008 - - RMDXK10D28 RCDXK1D28
1.12
2 #24 solid mil-w-76 type LW 24 0.047"
max
1/.0201 - - RMDXK10D28 RCDXK1D28
0.71
Twisted pair solid mil-w-81822/3 28 0.028"
max
1/.0126 0.32 - - RMDXK10D28 RCDXK1D28
169
UTO Series | Appendices
Female contact
Strip lengths 6.35±0.41 Outer hyring Twisted pair Inner supporting Outer female contact
sleeve Inner pin
of cable YOC074 adapter
RMD26L-1 RCDX60-2
YORK-090 RCDXB-055-1
Supporting
Outer hyring sleeve
Male contact
Outer male contact Inner supporting Outer hyring
Inner socket Twisted pair 7.95±0.41
RMDX60-2 sleeve adapter YOC074
RFD26L-1 Strip lengths
RMDXB-055-3 YORK-090 Conductor "Y" of cable
15.54±0.41
5.94 ±0.41
15.54±0.41
170
UTO Series | Appendices
• Select appropriate monocrimp coax twisted pair contact and cable combination.
• Select appropriate crimp tooling (hand tool, S-die set, stop bushing).
• Strip the twisted pair cable to the designated wire strip lengths. See cable strip lengths
• Insert the stripped cable into the contact. One cable is to be inserted into the
inside diameter of hyring, and pushed forward into the inner contact. The
second cable is to be inserted between the outside diameter of hyring and the
inside diameter of the outer contact body.
• Crimp the contact.
RMDX60
Cable strip length Male coax contact
B C
RCDX60
Female coax contact
A
16 min.
die set fully closed measured with die set fully closed
171
UTO Series | Appendices
Contact assembly with dielectric diameter over 1.4mm - without inner supporting sleeve
15.88±0.41
Outer male contact Outer hyring 7.95 ±0.41
Inner socket Strip lengths
RMDX60-2 YOC074
RFD26L-1 4.37±0.41
of cable
Contact assembly with dielectric diameter under 1.4mm - with inner supporting sleeve
17.53±0.41
Outer male contact Inner supporting Outer hyring 9.12 ±0.41
Inner socket Strip lengths
RMDX60-2 sleeve YOC074
RFD26L-1 RMDXB-055-3 of cable
7.54±0.41
172
UTO Series | Appendices
Contact assembly with dielectric diameter over 1.4mm - without inner supporting sleeve
11.13±0.41 Outer hyring Inner pin Outer female contact
Strip lengths
YOC074 RMD26L-1 RCDX60-2
of cable 4.37
±0.41
Contact assembly with dielectric diameter under 1.4mm - with inner supporting sleeve
11.13±0.41 Outer hyring Supporting sleeve Inner pin Outer female contact
YOC074 RCDXB-055-1 RMD26L-1 RCDX60-2028
Strip lengths
6.35±0.41
of cable
- Assemble supporting sleeve over dielectric and under braid until the inner pin snaps into place crimp in place as shown
- Assemble inner pin to inner conductor, push back against - The cable braid (shield) should now cover the
sleeve and crimp barrel of the outer female contact as shown
Supporting
Outer hyring sleeve
173
UTO Series | Appendices
Inner conductor
Cable Male Female Crimp Die Stop Cable strip length Braid crimp
crimp
reference contact contact tool set bushing
A B C g dim t dim g dim t dim
CDC PIN22939200 RMDX6046D28 RCDX6016D28 S80 SL105 4.19 5.97 8.51 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84
CDC PIN22939200 RMDX6046D28 RCDX6016D28 S87 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84
CDC PIN245670000 RMDX6050D28 RCDX6016D28 S80 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
KX21TVT (europe)
RMDX6034D28 RCDX6034D28 S82 SL105 5.08 6.35 8.89 1.30/1.17 1.32/1.17 2.84/2.74 3.07/2.9
RG178 B/U
RG178 / BU RMDX6050D28 RCDX6016D28 S87 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84
ampex RMDX6032D28 RCDX6032D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
TI PN 920580 RMDX6024D28 RCDX6024D28 S82 SL105 5.08 6.35 8.89 1.35/1.19 1.42/1.27 2.87/2.74 3.07/2.9
RG174/U RMDX6032D28 RCDX6032D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
Honeywell PN 58000062 RMDX6026D28 RCDX6026D28 S82 SL105 5.08 6.35 8.89 1.35/1.19 1.42/1.27 2.87/2.74 3.07/2.9
RG188A/U RMDX6036D28 RCDX6036D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
RG316/U RMDX6036D28 RCDX6036D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95
PRD PN M10SG8 ASSY'Y
RMDX6018D28 RCDX6018D28 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97
247AS-C1123-001 TOOL DIE SET
M10S1J STOP BUSHING
PRD PN 247AS-C1251 RMDX6018D28 RCDX6018D28 M10S1J TOOL 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97
raychem 5024A3111 RMDX6052D28 RCDX6052D28 S88 SL105 5.08 6.35 11.68 1.37/1.27 1.45/1.32 2.92/2.79
raychem 5026e1614 RMDX6036D28 RCDX6036D28 M10SG8 ASSY'Y 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97
TOOL DIE SET
JUDD C15013010902 RMDX6036D28 RCDX6036D28 STOP BUSHING 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97
M10S1J TOOL
inner cond. #30,
RMDX6050D28 - S80 SL105 5.1 6.35 8.9 - - - -
braid diam 2.64
inner cond. #30,
RMDX6050D28 - S87 SL105 4.2 6.35 8.5 - - - -
braid diam 2.29
inner cond. #28,
RMDX6032D28 RCDX6032D28 S80 SL105 5.1 6.35 11.7 - - - -
braid diam 2.9
inner cond. #26,
RMDX6024D28 RCDX6024D28 S82 SL105 5.1 6.35 8.9 - - - -
braid diam 1.78
inner cond. #26,
RMDX6026D28 RCDX6026D28 S82 SL105 5.1 6.35 8.9 - - - -
braid diam 3.05
A RCDX60
Female coax contact
B
C
174
UTO Series | Appendices
Glossary of Terms
• Clearance • CTI (Comparative Tracking Index)
Per the IEC 60664-1 it is the shortest The CTI value is commonly used to characterise the electrical
distance between two conductive parts breakdown properties of an insulating material. It allows users
even over the air. to know the tendency to create creepage paths. This value
represents the maximum voltage after 50 drops of ammonium chloride
solution without any breakdown.
• Creepage distance
Per the IEC 60664-1 it represents the
shortest distance along the surface • RTI (Relative temperature Index):
of the insulating material between two Extract from ULs website:
conductive parts. Air gap Maximum service temperature for a material, where a class of
Creepage distance critical property will not be unacceptably compromised through
chemical thermal degradation, over the reasonable life of an
• Working voltage electrical product, relative to a reference material having a
Per the IEC 60664-1 it is the highest r.m.s. value of A.C. or D.C. voltage confirmed, acceptable corresponding performance defined RTI.
across any particular insulation which can occur when the equipment is
supplied at rated voltage. - RTI Elec: Electrical RTI, associated with critical electrical
insulating properties.
• Rated impulse voltage - RTI Mech Imp: Mechanical Impact RTI, associated with
Impulse withstands voltage value assigned by the manufacturer to critical impact resistance, resilience and flexibility properties.
the equipment or to a part of it characterizing the specified withstand
capability of its insulation against transient overvoltage. - RTI Mech Str: Mechanical Strength (Mechanical without
Impact) RTI, associated with critical mechanical strength where
impact resistance, resilience and flexibility are not essential.
• Working current
It is the maximum continuous and not interrupted current able to be
carried by all contacts without exceeding the maximum temperature of
the insulating material.
• Transient voltage
Extract from the IEC 60664-1: Short duration overvoltage of a few
millisecond or less, oscillatory or non-oscillatory, usually highly damped.
Appendices
175
UTO Series | Appendices
Drilling Pattern
Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm
3.1
3
3
1.6
0.8
10
0.7
1.5
2.5
3.3
3
3
2.6 2.6 3 3 2.8 3 3 3 2.5
3
0.9
4
12
4.5
2.8
3.1
3
3.1 3.1 4.4 3.4 4.9 3.3
142G1
147 148
5.2
5.2
4.2
2.5
0.4
2.1
2.4
5.3
2
3.6 3.6 6.4 3.2
4.5 5
14
1412 1492 1419
5.1 5.7 6.6 4.9
5.9
4.6
5.7
2.9
2.8
1.5
1.4
0.8
0.3
2.4
2.3
2.2
4.5
5.1
5.9
176
UTO Series | Appendices
1619 7.7
1626
4.4 6
6.5 3.8 1.7 3.3
8.1
7.5
7.4
5.4
4.5
2.3
2.
1.6
1
16
0.9
0.8
2.8
3.8
4
5.1
6.6
2.7 1 3 1.7
7.9
7.5 4.8 4.5
7 8
1823 1832
8.7
5.3 7.2
3.1 4.8
8.3
2.4 1.6
5 6.7
5.4
1.9
7.7
8.9
5.8
7.7
5.5
2.4
4.9
18
2.4
0.8
6.7
8.6
3.8
8.5
4
9.1
5.6
3.4
4.8
3.5 3.7
1.6 3.3
4.4 6.1
5.7 8.1
9
Appendices
177
UTO Series | Appendices
2028 2030
5.4 10.1 9.3
2.5 4.9 7.1 5.8
1.6 1.5 3.8 1.9
10.1
9.2
5.4
7.1
5.8
5.2
7
2.5
3.4
1.9
0.6
1.6
1.5
0.5
3.8
2.2
4.2
4.9
3.8
6.2
10
9.3
6
0.6 0.5
3.4 3.8 2041
20 5.7 4.2 5.9 10.6
7 6 3.3 6.2
10 9.2 2.9 3.2
10.1
7.2
6.2
3.2
6.3
2.3
0.8
4.0
3.4
0.8
6.9
2.5
3.8
8.5
10.6
5.3
1.7 1.6
4.7 3.7
7.1 6.7
10.1 8.5
2235 2238
6.7
3.9 5.5
1.9 3.3
11.6
11.4
8.4
7.9
10.2
6.2
6.7
4.2
4.6
2.2
3.9
6.5
0.1
0.9
2.5
22
1.4
1.9
1.9
2.8
5.5
3.9
11.6
10.1
8.1
6.3
7.8
11
9.1
6
178
UTO Series | Appendices
2255
6.6
8.2
3.3
22
1.6
4.9
9.9
11.5
5.7 2.8
11.4 8.5
2448
11.4
7.6
3.8
1.9
2461
9.5
5.7
13.3
12.3
10.4 13.3
10.1 7.2
6.6 3.3 9.1 6.0
13.2 9.9 7.9 4.3
4.9 3.7
2.6 1.7
24 11.5
12.7
9.2
8.5
11
8.7
7.1
5.6
5.8
4.4
5
3.1
2.3
1.1
2.5
0.2
0.7
4.1
1
7.2
3.3
10.2
9.6
9.9
5.9
5.4
3.5
11.9
6.7
13.1
7.9
13.6
3.3 3.4
5.7 6.5
6.3 6.7
Appendices
8.6 9.3
9.9 11.5
11.5 12.9
13.6
179
UTO Series | Appendices
Discrimination/Keying Methods
In applications where similar connectors are used next to each other, Discrimination key degrees
mismatching can cause disturbances, system failure or even danger to Shell size Layout
operating personnel. W X Y Z
To eliminate mismatching, all Trim Trio® connectors are offered with 103 - - - -
discrimination keys to avoid interconnection system errors. In addition, 102W2 - - - -
the connector insert can also be rotated inside the shell to create custom
10 104 45° - - -
keying options.
103W3 - - - -
106 90° - - -
124 - - - -
12 128 26° - - -
1210 60° 155° 270° 295°
142G1 - - - -
147 - - - -
148 - - - -
14
1412 60° - - -
1492 49° 71° 145° -
1419 30° 165° 315° -
1619 30° 165° - 315°
16
1626 60° - 275° 338°
1823 - 158° - 270°
18
1832 85° 138° 222° 265°
2028 79° - 259° -
Connectors with rotated inserts can be ordered by adding the suffix W, X,
20 2030 34° 90° 123° 259°
Y or Z to the standard part number.
e.g. UT0W0106PH (standard key) UT0W0106PWH (W key) 2041 45° 126° 225° -
2235 13° 162° 198° 265°
Consult us for overmoulded harnesses. 22 2238 15° 47° 150° 331°
2255 30° 142° 226° 314°
2448 60° 120° 189° 351°
24
2461 90° 180° 270° 324°
180
UTO Series | Appendices
181
UTO Series | Appendices
182
UTO Series | Appendices
183
UTO Series | Appendices
184
UTO Series | Appendices
SL105......................... P.174
SL46D2........................ P.172
SL471......................... P.172
UH25.......................... P.139
VGE10077A..................... P.139
VGE10078A..................... P.139
Appendices
185
UTO Series | Appendices
Notes
186
Your local contact
[email protected]
www.souriau-industrial.com
protection:
certified paper
Advancement of sustainable