Brosur UPS Merk Centiel Essential Power
Brosur UPS Merk Centiel Essential Power
SWISS
www.centiel.com
EssentialPower™, The Single Phase
EssentialPower™ is The On-Line, true double-conversion, single phase Uninterruptible Power Supply.
From 1 to 20kVA, EssentialPower™ provides the most flexible and reliable solution ideal for small network devices,
servers, point-of-sale, work station clusters and light-industrial installations. EssentialPower™ satisfies any entry-level
mission critical application demanding high availability and flexibility.
EssentialPower™ offers built-in internal batteries from 1 to 6kVA, and the possibility to connect up-to 4 matching
battery cabinets for autonomies of up to 4 hours.
Benefits
Standalone Tower or 19”
Rack-mount configurations
Cold start
Parallel operation
from 6kVA to 20kVA
Frequency converter
operation (50 Hz or 60 Hz)
kVA=kW
FROM 6 TO 10 KW
Connectivity
With a variety of options, like, communication cards, Expansion relays, SNMP and ambient monitoring applications,
Essential Power™ can be easily integrated into any environment and building management system.
Battery Autonomy
EssentialPower™
11RT 1kVA 2kVA 3kVA 6kVA 10kVA
UPS-EP001-11-I03-2U UPS-EP002-11-I06-2U UPS-EP003-11-I06-2U UPS-EP006-11-E-2U
UPS TYPE UPS-EP001-11-I03-2US UPS-EP002-11-I06-3US UPS-EP003-11-I06-4US UPS-EP006-11-I20-4U
UPS-EP010-11-E-3U
Battery Type 7Ah / 9Ah 7Ah / 9Ah 7Ah / 9Ah 7Ah / 9Ah 7Ah / 9Ah
UPS + 2 EPBATxx 54 / 69 50 / 64 31 / 40 17 / 22 8 / 11
EssentialPower™
31RT 10kVA 15kVA 20kVA
UPS + 4 EPBATxx 25 / 32 14 / 18 9 / 12
GENERAL DATA
Output rated power 1000VA /900W 2000VA /1800W 3000VA /2700W 6000VA /6000W 10000VA /10000W
Internal Batteries YES YES YES 2U: N.A.; 4U: YES N.A.
INPUT
Voltage range 110~300 Vac (Single + G) 110~300 Vac (Single + G) 110~300 Vac (Single + G) 110~280 Vac (Single + G) 110~280 Vac (Single + G)
Input Current Distorsion ≤ 6% (full load) ≤ 6% (full load) ≤ 6% (full load) ≤ 3% (full load) ≤ 3% (full load)
OUTPUT
BATTERY
FUNCTIONS
Audible or Visual Line failure/ Battery low/ Transfer to Bypass/ System Fault
Programmable outlet Yes (standard) Yes (standard) Yes (standard) N.A. N.A.
PHYSICAL
2U: 440x88x405 2U: 440x88x600 2U: 440x88x600 2U: 440x88x685
Dimensions (WxHxD,mm) 3U: 440x132x685
2US: 440x88x405 3US: 440x132x432 4US: 440x176x432 3U: 440x176x685
E: 11/24.25
Net Weight (kgs/lbs) 11.7/25.8 21.8/48.1 24.6/54.2 11/24.25
I20: 9/19.8 (5Ahx20)
ENVIRONMENTAL
COMMUNICATIONS
Option RS485 (Modbus), Dry Contact Relay, SNMP/WEB Card RS232, RS485, Dry Contact Relay, SNMP/WEB Card
0,9
NO
Up to 4 units 2U
1-6 kVA
277 - 485 Vac (3Ph + N +PE)
±1%
3:1
3U
105% - 150% 600sec 10kVA
Up to 91%
≥95%
E: External: 20
2A 4.5 A 4.5 A
Yes (standard)
4U
N.A. 6kVA with Batteries
0~40°C / 32~104°F
RS-232, EPO
IEC / EN62040-1
5U
IEC / EN62040-2 (C2) 15,20kVA
IEC / EN62040-3