0% found this document useful (0 votes)
88 views9 pages

Honeywell XLS3000

The Honeywell XLS3000 is an intelligent fire alarm control panel designed for medium to large-scale facilities, supporting up to 3,180 intelligent addressable devices. It features a modular design, a large LCD display for vital information, and various options for voice communication and advanced detection products. The XLS3000 also includes networking capabilities, extensive programming options, and compliance with industry standards for enhanced fire safety and evacuation management.

Uploaded by

mohyeyons114
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views9 pages

Honeywell XLS3000

The Honeywell XLS3000 is an intelligent fire alarm control panel designed for medium to large-scale facilities, supporting up to 3,180 intelligent addressable devices. It features a modular design, a large LCD display for vital information, and various options for voice communication and advanced detection products. The XLS3000 also includes networking capabilities, extensive programming options, and compliance with industry standards for enhanced fire safety and evacuation management.

Uploaded by

mohyeyons114
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

XLS3000

Intelligent Addressable Fire Alarm Control Panel

The Honeywell XLS3000 is an intelligent fire


alarm control panel designed for medium- to
large-scale facilities.
The Honeywell XLS3000 is an intelligent fire alarm control panel (FACP) designed for medium- to
large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety,
and the XLS3000 is ideally suited for these applications. The XLS3000 is ideal for virtually any
application because it features a modular design that is configured per project requirements.
With one to ten Signaling Line Circuits (SLCs), the XLS3000 supports up to 3,180 intelligent
addressable devices.
Information is critical to fire evacuation personnel, and the XLS3000’s large 640-character Liquid
Crystal Display (LCD) presents vital information to operators concerning a fire situation, fire
progression, and evacuation details.
A host of other options are available, including single- or multi-channel voice; firefighter’s
telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection
products for challenging environments; wireless fire protection; and many additional options.
When combined with a Honeywell Enterprise Buildings Integrator (EBI™), the XLS3000 becomes
part of an owner-operated proprietary monitoring system, allowing the connection of standalone
or networked panels.

XLS3000 Intelligent Addressable


Fire Alarm Control Panels
(Second image shows a system
with the XLS-DVC audio option)

FEATURES AND BENEFITS


• Certified for seismic applications when used • Network options: • 4,000 event history file in nonvolatile
with the appropriate seismic mounting kit. - High-speed network for up to 200 nodes memory, plus a separate 1,000-event alarm-
• Complies with UL 2572 Mass Notification (XLS3000, XLS140-2, XLS140, only file.
Systems (XLS3000 version 20 or higher). XLS120(C), XLS-NCA/-NCA2 Network • Alarm Verification selection per point, with
• One to ten isolated intelligent Signaling Line Annunciator, or XLS-DVC-EM, and automatic counter.
Circuits (SLC) Class A, B, or X. Honeywell Enterprise Buildings Integrator • Autoprogramming, walk test, positive alarm
• Wireless fire protection using SWIFT® Smart [EBI]). sequence, and time scheduling.
Wireless Integrated Fire Technology. See 74- - Standard network or up to 103 nodes • Multiple central station communication
5175. (XLS3000, XLS140-2, XLS140, options:
• Up to 159 detectors and 159 modules per XLS120(C), XLS-NCA/-NCA2 Network - Standard UDACT
SLC; 318 devices per loop/3,180 per FACP or Annunciator, or XLS-DVC-EM, and - Internet
network node. Honeywell Enterprise Buildings - Internet/GSM
• Detectors can be any mix of photo, thermal, Integrator [EBI]). Up to 54 nodes when • FM6320 approved Gas Detection System
or multi-sensor; wireless detectors are XLS-DVC-EM is used in network paging. with TC809C1004 module and any FM listed
available for use with the XLS-WSG(CDN). • Built-in Alarm, Trouble, Security, and gas detector.
• Modules include addressable pull stations, Supervisory relays. • EIA-232 printer port; EIA-485 annunciator
normally open contact devices, two-wire • VeriFire® Tools online/offline program port.
smoke detectors, notification, or relay; option.
wireless modules are available for use with • Backwards compatible with FlashScan® and
the XLS-WSG(CDN). CLIP SLC devices.
• Large 16 line, 640 character LCD backlit • With built-in Degraded Mode operation, the
display or use display-less as a network node. system is capable of general alarm if a fire
alarm condition is present even if the central
processing unit (CPU) fails.
DESCRIPTION priority functions. Remote ACK/Signal Silence/System reset/Drill
can be done via monitor modules. The XLS3000 supports the SCS
SIGNALING LINE CIRCUITS Series smoke control system in both HVAC and FSCS modes.
The Honeywell XLS3000 Intelligent Addressable Fire Alarm System DISPLAY
supports up to ten isolated intelligent signaling line circuits with The XLS3000 display is a backlit LCD with 640-character display
Class A, B, or X. Each of the 10 circuits can have up to 159 detectors and a program keypad. The display allows up to nine users, each
(any mix of photo, laser photo, thermal, or multi-sensor) and 159 with a password and selectable access levels. The display has 11
modules (Addressable pull stations, normally open contact devices, LED indicators: Power, Supervisory, Point Disabled, Fire Alarm,
two-wire smoke detectors, notification, or relay) with a total of 318 System Trouble, CPU Failure, Pre-Alarm, Other Event, Controls
device per loop/3,180 per FACP or network node. Actual circuit Active, Security, and Signals Silenced. There are also five membrane
loading depends on SLC communication protocol. switch controls: Acknowledge, Signal Silence, Drill, System Reset,
Weekly Occupancy Schedules allow changing sensor sensitivity by and Lamp Test.
time of day, and day of week. An optional 2,040 point digital alarm
communicator transmitter (DACT) is available for use with central INDUSTRY LEADING DETECTOR DESIGNS
monitoring stations. Annunciator support, including custom • Addressable detectors available for photo, heat, CO, IR, and
graphics, is provided via an EIA-485 annunciator port. An EIA-232 combinations
printer port is also provided. The history file has a 4,000 event • Color kits available for aesthetic use
capacity in nonvolatile memory, plus a separate 1,000 event alarm- • Single-ended beam smoke detectors
only file. Advanced history filters allow sorting by event, time, date, or • Wireless detectors for use with SWIFT Wireless Gateway r
address. Alarm verification selection can be done per point, with
automatic counter. Autoprogramming and Walk test reports are FLASHSCAN®
provided. The panel includes positive alarm sequence (PAS) At the heart of the XLS3000 is a set of detection devices and device
Presignal functionality. Timer options include Silence Inhibit and protocol — FlashScan. FlashScan is an all-digital protocol that gives
Auto Silence. superior precision and high noise immunity.
Field programmability, with check and compare, is provided on a PC As well as giving quick identification of an active input device, this
with the VeriFire Tools program. Up to 1,000 powerful Boolean logic protocol can also activate many output devices in a fraction of the
equations can be used. Non-alarm points are provided for lower time required by competitive protocols. This high speed also allows
SLC Intelligent Loop

DEVICES

XLS-WSG(CDN)
TC840M3021 S464G1007 XP6/10
Up to 32 TC806B3010 Input/Output Modules
LCD-160 TC808B3011
remote
LCD2-80 displays TC840C3206 TC809A1059 TC810R1024
…etc. IDC Relay Contact
EIA-485

EIA-485 3072 annunciator/control points

XLS3000-CPUD
display or
XLS3000-CPUND
ACM-8R Relay ACM/AEM-24AT LED LDM-32
Control Annunciator Custom Graphics

Dual phone lines


to Central Station
h7070blok-2013.wmf

Optional 2048-point UDACT


EIA-232

XLS3000
Shown in CAB-C4 with display
DVC-EM audio in CA-1
in second tier PRN Series
Printer

Note: XLS3000-CPU firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal
mode, but not both at the same time.

XLS3000 Sample System Options

Page 2 of 9 — 74-4034-16 • 9/14/2022


the XLS3000 to have the largest device per loop capacity in the Drift Compensation and Smoothing. Drift compensation allows
industry — 318 points — yet every input and output device is the detector to retain its original ability to detect actual smoke, and
sampled in less than two seconds. Up to 159 outputs can be resist false alarms, even as dirt accumulates. It reduces
activated in less than 5 seconds. The microprocessor-based maintenance requirements by allowing the system to automatically
FlashScan detectors have bicolor LEDs that can be coded to perform the periodic sensitivity measurements required by
provide diagnostic information, such as device address during Walk NFPA 72. Smoothing filters are also provided by software to remove
Test. transient noise signals, usually caused by electrical interference.
The multicolor LEDs blink the device address during a Walk Test. Maintenance Warnings. When the drift compensation performed
FlashScan operates with a fully digital, high-precision protocol. The for a detector reaches a certain level, the performance of the
multi-detector algorithm involves nearby detectors in the alarm detector may be compromised, and special warnings are given.
decision, and the FlashScan device also uses drift compensation. There are three warning levels: (1) Low Chamber value; (2)
The FlashScan protocol incorporates nine levels of pre-alarm XLS Maintenance Alert, indicative of dust accumulation that is near but
intelligent sensing, each of which can be manually adjusted. Several below the allowed limit; (3) Maintenance Urgent, indicative of dust
programmable devices are available: accumulation above the allowed limit.

• Photo – 0.5 to 2.35%/foot obscuration. Sensitivity Adjust. Nine sensitivity levels are provided for alarm
• High-Sensitivity Photoelectric (VIEW®) – Open Air Protection (0.5% - detection. These levels can be set manually, or can change
2.0%/ft. obscuration), Special Applications (0.02%- 0.5%/ft. automatically between day and night. Nine levels of pre-alarm
obscuration) sensitivity can also be selected, based on predetermined levels of
• Multi-Criteria Detector – Open Air Protection (2.52-3.89%/ft. alarm. Pre-alarm operation can be latching or self-restoring, and
obscuration), Special Applications (1.13-2.52%/ft. obscuration) can be used to activate special control functions.
FlashScan has a self-optimizing pre-alarm, automatic detector Self-Optimizing Pre-Alarm. Each detector may be set for “Self-
sensitivity testing, and two levels of maintenance alert. It also Optimizing” pre-alarm. In this special mode, the detector “learns” its
provides programmable activation of sounder/relay bases during normal environment, measuring the peak analog readings over a
alarm or pre-alarm. The Read Status displays the level of detector long period of time, and setting the pre-alarm level just above these
cleanliness. normal peaks.
Cooperating Multi-Detector Sensing. A patented feature of
INTELLIGENT SENSING intelligent sensing is the ability of a smoke sensor to consider
Intelligent sensing is a set of software algorithms that provide the readings from nearby sensors in making alarm or pre-alarm
XLS3000 with industry-leading smoke detection capability. These decisions. Without statistical sacrifice in the ability to resist false
complex algorithms require many calculations on each reading of alarms, it allows a sensor to increase its sensitivity to actual smoke
each detector, and are made possible by the very high-speed by a factor of almost two to one.
microcomputer used by the XLS3000.

Network Diagram
RPT-
WF

TCP/IP
EBI

Block Diagram

FNA
XLS•NET PRN
Sample Node Configurations XLS140-2
Router
XLS3000
Key:
XLS•NET
Twisted-Pair Wire ACS

XLS•NET
Dual Fiber-Optic Link
LCD-80
Other Interfaces
h6856cn2.wmf

OPTIONAL
Class X
Connection
DAA DAA

PRN

XLS-NCA2
speakers speakers
phones phones

XLS•NET Block Diagram ACS

Page 3 of 9 — 74-4034-16 • 9/14/2022


FIELD PROGRAMMING OPTIONS LCM-320: Loop Control Module, CLIP/FlashScan Protocol.
Autoprogram is a time saving feature. The XLS3000 “learns” what Provides one CLIP/FlashScan SLC. XLS3000 supports up to five
devices are physically connected and automatically load them in LCM-320s and five LEM-320 expanders for a total of ten SLCs. See
the program with default values for all parameters. Requiring less 85-3056.
than one minute to run, this routine allows the user to have almost LEM-320: Loop Expander Module, CLIP/FlashScan Protocol.
immediate fire protection in a new installation, even if only a portion Expands an LCM-320. See 85-3056.
of the detectors are installed.
NETWORKING OPTIONS
VeriFire® Tools is an offline programming and test utility that can
XLS-NCA2/-C: Network Control Annunciator. One required per
greatly reduce installation programming time, and increase
XLS-NET. Provides annunciation and control of all points on XLS-
confidence in the site-specific software. It is Windows® based and
NET. Order XLS-NCA2-C for ULC applications. Non-English
provides technologically advanced capabilities to aid the installer.
versions are available: XLS-NCA-2-FR (French), XLS-NCA-2-PO
The installer may create the entire program for the XLS3000 in the
(Portuguese), XLS-NCA-2-RU (Russian), XLS-NCA-2-SC (Standard
comfort of the office, test it, store a backup file, then bring it to the
Chinese), XLS-NCA-2-SP (Spanish). See 74-4045.
site and download from a laptop into the panel.
NCM-W, NCM-F: Network Communications Modules. Wire and
Releasing Service. The system will release on any of ten
multi-mode fiber versions available. One required for each network
independent hazards. There are three options of sophisticated
node (XLS3000, XLS140, XLS140-2, XLS-DVC-EM, BACNET
cross-zone sensing. There is a delay timer and adjustable discharge
GATEWAY, Q7055C1034) on XLS-NET. Mounts in a standard
timers, and there are four options for Abort.
chassis position or on a BMP-1 plate. See 85-3007.
Emergency Voice and Firefighter’s Telephone. The XLS3000 has
XLS-NCM-EBI-W: Network Communication Module, Wire. Used in
digital message generation, hard-wired voice control options, and a
applications where the Q7055C1034 (Fire Network adapter) is
Firefighter’s telephone option. The voice message is powered by
mounted remotely next to an EBI server. The XLS-NCM-EBI-W
high-efficiency amplifiers (35, 50 and 75 watt DAA2/DAX Series, or
mounts inside the EBI server (in an PCI slot) and communicates
100 and 120 watt DS Series). There is an optional backup tone
with the Q7055C1034. See 85-3007.
generator and amplifier available. For the Emergency Voice feature,
the newly introduced Digital Voice Command provides eight XLS-NCM-EBI-F: Network Communication Module, Multi-Mode
channels of one-way alarm broadcast and five channels of two-way Fiber. Used in applications where the Q7055C1034 (Fire Network
communications with remote fire telephones. See 74-4033. adapter) is mounted remotely next to an EBI server. The XLS-NCM-
EBI-F mounts inside the EBI server (in an PCI slot) and
XLS3000-CPU. The control panel XLS3000-CPU is contained on
communicates with the Q7055C1034. See 85-3007.
one printed circuit board: the central processing unit. The
XLS3000-CPU can be purchased with or without keypad and HS-NCM-W(-2), HS-NCM-MF, HS-NCM-SF, HS-NCM-WMF(-2),
display; connections are identical on both versions. (See Main HS-NCM-WSF(-2), HS-NCM-MFSF: High-speed Network
System Components for Canadian and non-English versions.) Communications Modules that can connect to two nodes. Wire,
single-mode fiber, multi-mode fiber, and media conversion models
PRODUCT LINE INFORMATION are available. See 74-4082.
RPT-W, RPT-F, RPT-WF: Repeater board with wire connection
CONFIGURATION GUIDELINES (RPT-W), multi-mode fiber connection (RPT-F), or allowing a
change in media type between wire and fiber (RPT-WF). Not used
Stand-alone and network systems require a main display. On single-
with high-speed networks. See 85-3007.
FACP systems (one XLS3000), the display option is the XLS3000-
CPUD. On network systems (two or more networked fire panel nodes), Q7055C1034: Fire Network adapter. Used to connect XLS-NET or a
at least one XLS-NCA2/-C is required. Options listed as follows. standalone XLS3000 to Honeywell EBI. Requires one NCM-W/F or
one XLS-NCM-EBI-W/F. See 74-4017.
MAIN SYSTEM COMPONENTS
BACNET-GW-3: BACnet interface for the XLS3000 or XLS-NET.
XLS3000-CPUD: XLS3000 with display. Includes CPU, 640 Allows the XLS3000 to be connected to any BACnet capable
character display with keypad. Order XLS3000-CPUDC for ULC application (subject to local AHJ approval). See 85-3067.
applications. Non-English versions are available: XLS3000-CPUD-
FR (French), XLS3000-CPUD-PO (Portuguese), XLS3000-CPUD- XLS-GW-EM-3: XLS•NET Gateway, embedded. See 74-5084.
RU (Russian), XLS3000-CPUD-SC (Standard Chinese), XLS3000- HWS-3: Honeywell Web Server. See 74-5171.
CPUD-SP (Spanish). XLS-LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic
XLS3000-CPUND: XLS3000 without display. Includes CPU only. and high-speed XLS-NET networks through the XLS•NET Gateway.
AMPS-24: Main power supply and battery charger for the XLS3000. See 74-5148.
One required for each XLS3000 CPU used in 110/120 VAC OAX2-24V: UL-listed LED sign, used with XLS-LEDSIGN-GW. See
applications. Charges 25 to 200 AH batteries. Primary input power: 74-5148.
110/120 VAC, 50/60 Hz, 4.5 A (maximum). Mounts in the bottom
left hand section (battery row) of a XLS-CAB-4 enclosure. See 85- AUXILIARY POWER SUPPLIES AND BATTERIES
3057. EOL-CR/CW: End of line relay plate. Required for certain Canadian
AMPS-24E: Main power supply and battery charger for the Applications. See 85-3062.
XLS3000. One required for each XLS3000 CPU used in 240 VAC APS2-6R: Auxiliary power supply. Provides two 24 VDC circuits,
applications. Charges 25 to 200 AH batteries. Primary input power: each rated for 3.0 A in alarm and 2.0 A continuous. Commonly used
240 VAC, 50/60 Hz, 2.25 A. Mounts in the bottom left hand section for the operation of peripheral audio/visual devices or any other
(battery row) of a XLS-CAB-4 enclosure. See 85-3057. application requiring 24VDC. See 85-3050.

Page 4 of 9 — 74-4034-16 • 9/14/2022


ACPS-610: 6.0 A or 10.0 A addressable charging power supply. See to 96 points with AEM-24AT expanders. Active/Alarm LEDs can be
85-3109. programmed by point to be red, green or yellow; the Trouble LED is
HPF24S6: 24 VDC NAC Remote Power Supply, 6A. Provides built-in always yellow. Mounts on a DP-DISP or ADP-4B. See 85-3004.
NAC synchronization. 120 VAC only. UL LISTED. AEM-24AT: Same LED and switch capabilities as ACM-24AT;
HPF24S6C: Same as HPF24S6, but ULC LISTED. expands the ACM-24AT to 48, 72, or 96 points (24 points per AEM-
24AT). Mounts on a DP-DISP or ADP-4B. See 85-3004.
HPF24S6E: Same as HPF24S6, but 240 VAC.
ACM-48A: ACS annunciator – provides 48 programmable LEDS for
HPF24S8: 24 VDC NAC Remote Power Supply, 8A. Provides built-in annunciation of points. Can be expanded up to 96 points with an
NAC synchronization. 120 VAC only. UL LISTED. AEM-48A expander. Active/Alarm LEDs can be programmed by
HPF24S8C: Same as HPF24S8, but ULC LISTED. point to be red, green or yellow; the Trouble LED is always yellow.
Mounts on a DP-DISP or ADP-4B. See 85-3004.
HPR24S8E: Same as HPF24S8, but 240 VAC.
AEM-48A: Same LED capabilities as ACM-48A; expands the ACM-
BAT Series: Batteries, 12V, Sealed Lead-Acid. AMPS-24 is
48A to 96 points. Mounts on a DP-DISP or ADP-4B. See 85-3004.
compatible with 7 AH to 200 AH batteries. See 85-3072.
ACM-8R: ACS Relay Module. Used to provide up to 8 remote form C
AUDIO OPTIONS contacts. Can be located up to 6,000 ft (1828.8 m) from the panel.
See “Enclosures, Chassis, and Dress Plates” on page 7 for mounting See 85-3046.
hardware. LCD-160: Remote Annunciator. Mimics the XLS3000 Display.
XLS-DVC-EM Digital Audio System: XLS-DVC Digital Voice Mounts in an XLS-ABS-2D(R), XLS-ABS-4D(R), XLS-ABF-2B, XLS-
System. Networkable or standalone with a XLS3000. See 74-4033. ABF-4B enclosure, or a DP-DISP, or ADP-4B dress plate. Order LCD-
160C for ULC applications. See 85-3058.
DVC-RPU: Digital Voice Command Remote Paging Unit for use with
DVC-EM. Includes the keypad/display. See 74-5170. LCD2-80: Terminal and ACS mode. 80-character, backlit LCD
display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per
DS-DB: Digital Series Distribution Board, provides bulk
FACP. See LCD2-80 (74-5091).
amplification capabilities to the XLS-DVC-EM while retaining digital
audio distribution capabilities. Can be configured with up to four SCS Series: Smoke control station. Used for UL listed smoke control
DS-AMPs, supplying high-level risers spread throughout an applications. See 85-3048.
installation. See 74-5139. LDM-32: Lamp Driver module. Used to drive custom graphic
DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires annunciators. Mounts in a standard chassis position or inside a
DS-XF70V step-up transformer. Digital Series Amplifier, part of the graphic annunciator. See 85-3042.
DS-DB system. See 74-5141.
COMMUNICATORS (DACTS) AND TRANSMITTERS
DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for XLS-DVC-
UDACT-2: Universal Digital Alarm Communicator Transmitter, 636
EM, DS-DB distribution board, and DAA2/DAX Series amplifiers. See
channel. See 74-5143.
74-5078.
411 Series: 411 Series Slave Digital Alarm Communicator
DAA2 Series, DAX Series: XLS-DVC Digital Audio Amplifiers. Used
Transmitters. See 85-3063.
with the XLS-DVC-EM digital voice system, these amplifiers
communicate via the digital audio look to provide 8 channels of 411 UDAC: 411UDAC Standalone Digital Alarm Communicator/
audio messaging and 5 channels of firefighter's telephone Transmitter. Features remote upload and download capabilities.
communication over a single twisted pair of wire or fiber pair. See See 85-3064.
74-5137, 74-5138, 74-4032 and 85-3121. TM-4 Transmitter: Transmitter Module used for municipal box trip.
AA-30, AA-100, AA-120: Traditional Audio Amplifiers. Amplifies a Includes three reverse-polarity circuits and one municipal box
low level audio signal to high level audio at 30, 100 or 120 Watts. circuit. Mounts in a standard chassis position. See 85-3005.
Used with the XLS-DVC-EM when the DVC-AO Analog Audio Option
is used. See 85-3044. COMPATIBLE INTELLIGENT DEVICES
XLS-WSG(CDN) Wireless SWIFT Gateway: Addressable gateway
RM-1: Remote paging microphone series. See 85-3053.
supports wireless SLC devices. Order XLS-WSGCDN for ULC
AFAWS Series: Firefighter’s remote telephone enclosure. See 85- applications. See 74-5175.
3052.
TC840C3206/-IV: FlashScan, Addressable intelligent multi-criteria
ACT-2: Audio Coupling Transformer. See 85-3065. smoke sensors, photo, carbon monoxide, fixed temperature heat
DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers detector and infra-red (IR). ULC: TC840C3206CDN/-IV.
are compatible with XLS-DVC systems running SR4.0. For specific TC806C3022: FlashScan, Combined photoelectric and carbon
information on DAA-50 series amplifiers, refer to 74-4032. For monoxide sensor. ULC: TC806C3022CDN.
information on DAA-7525 Series, refer to 85-3121.
TC806C3011: FlashScan, Addressable carbon monoxide sensor.
PRINTERS, ACS DEVICES AND PERIPHERALS ULC: TC806C3011CDN.
PRN-7: 80-column printer. See 74-5186. TC808B3011: White, low-profile intelligent 135°F fixed thermal
sensor, FlashScan only. Must be mounted to one of the bases listed
DPI-232: Direct Panel Interface. Specialized modem for extending
below. ULC: TC808B3011CDN.
EIA-232 serial data links to remotely located control panels and/or
peripherals. Mounts in a standard chassis position. See 85-3006. TC808B3011-IV: Ivory, low-profile intelligent 135°F fixed thermal
sensor, FlashScan and CLIP. Must be mounted to one of the bases
ACM-24AT: ACS annunciator – provides 24 LEDS with control
listed below. ULC: TC808B3011CDN-IV.
buttons for annunciation and control of points. Can be expanded up

Page 5 of 9 — 74-4034-16 • 9/14/2022


TC808B3012: White, low-profile intelligent rate-of-rise thermal VEA-040-A10-HON: Intelligent VESDA-E aspiration detectorwith
sensor, FlashScan only. Must be mounted to one of the bases listed LED and LCD display, 40 point-addressable detection points.
below. ULC: TC808B3012CDN. Covers 36,000 square feet. See 74-5218. UL/ULC Listed.
TC808B3012-IV: Ivory, low-profile intelligent rate-of-rise fixed VES-A00-P-HON-UL: Intelligent scanning VESDA-E aspiration
thermal sensor, FlashScan and CLIP. Must be mounted to one of detector with LEDs. See DH-62040. UL 268 7th edition.
the bases listed below. ULC: TC808B3012CDN-IV. VES-A10-P-HON-UL: Intelligent scanning VESDA-E aspiration
TC808B3203: High temperature sensor with 190°F (87.8°C) fixed detector with 3.5" Display. See DH-62040. UL 268 7th edition.
temperature alarm. FlashScan mode only. White. Must be mounted DNR: InnovairFlex low-flow non-relay duct-detector housing. ULC:
to one of the bases listed below. ULC: TC808B3203CDN. DNRA. (Order TC806DNR(CDN) separately.) See 74-4076.
TC808B3203-IV: Ivory, low-profile intelligent 190°F thermal DNRW: Same as above with NEMA-4 rating, watertight. See 74-
sensor, FlashScan and CLIP. Must be mounted to one of the bases 4076.
listed below. ULC: TC808B3203CDN-IV
B224RB-WH, 14507371-003: White, low-profile relay base. See
TC840M3021/-IV: Addressable intelligent multi-criteria 85-3043. ULC: B224RBA-WH.
photoelectric, thermal and IR sensors. ULC: TC840M3021CDN,
TC840M3021CDN-IV. B224RB-IV: Ivory, plug-in System Sensor relay base. ULC:
B224RBA-IV.
TC847XR1001: Addressable intelligent single-ended beam smoke
detector. . UL/ULC-listed. B224BI-WH, 14507371-005: White, isolator base for low-profile
detectors. See 85-3043. ULC: B224BIA-WH.
TC806B3010: White, low-profile intelligent photoelectric sensor,
FlashScan only. ULC: TC808B3010CDN. B224BI-IV: Ivory isolator detector base. ULC: B224BIA-IV.

TC808B3010-IV: Ivory, low-profile intelligent photoelectric sensor. B300-6: White, standard flanged low-profile mounting base. (For
ULC: TC808B3010CDN-IV. 10-pack order B300-6-BP.) ULC: B300A-6.

TC806B3104: White, same as TC806B3010 but includes a built-in B300-6-IV: Ivory, standard flanged low-profile mounting base. ULC:
135°F (57°C) fixed-temperature thermal device. FlashScan only. B300A-6-IV.
ULC: TC806B3104CDN. B501-WHITE: European-style, 4" (10.16 cm) base. See 85-3043.
TC806B3104-IV: Ivory, same as TC806B3104 but includes a built- (For 10-pack order B501-WHITE-BP.) UL/ULC listed.
in 135°F (57°C) fixed-temperature thermal device. ULC: B501-BL: Black, 4” standard European flangeless mounting base.
TC806B3104CDN-IV. UL/ULC listed.
TC806DNR3000: White, low-profile intelligent photoelectric B501-IV: Ivory color, 4” standard European flangeless mounting
sensor, remote test capable. For use with DNR/DNRW. FlashScan base. UL/ULC listed.
only. ULC: TC806DNR3000CDN, for use with DNRA.
B200S-WH: White, intelligent programmable sounder base,
TC806DNR3000-IV: Ivory, low-profile intelligent photoelectric capable of producing a variety of tone patterns including ANSI
sensor, remote test capable. For use with DNR/DNRW. FlashScan Temporal 3. Compatible with synchronization protocol. See 85-
only. ULC: TC806DNR3000CDN-IV, for use with DNRA. 3043. ULC: B200SA-WH.
TC846A3013: White, intelligent high-sensitivity photoelectric B200S-IV: Ivory intelligent, programmable sounder base. ULC:
smoke detector. ULC: TC846A3013CDN. B200SA-IV.
TC846A3005CDN: Ivory, intelligent high-sensitivity photoelectric B200SCOA-WH: White intelligent, programmable sounder base in
smoke detector. ULC: TC846A3005CDN-IV. English/French (required in Canada for ULC applications with CO
VEP-A00-P-HON: Intelligent VESDA-E aspiration smoke detector detectors. Based on B200SA. ULC listed.
with LED display, 4 pipes, covers up to 21,520 square feet. See 74- B200SCOA-IV: Ivory intelligent, programmable sounder base in
5216. UL/ULC Listed. English/French (required in Canada for ULC applications with CO
VEP-A10-P-HON: Intelligent VESDA-E aspiration smoke detector detectors. Based on B200SA. ULC listed.
with LED and LCD display, 4 pipes, covers up to 21,520 square feet. B200S-LF-WH: White, low-frequency version of B200S. See 85-
See 74-5216. UL/ULC Listed. 3043.
VEP-A00-1P-HON: Intelligent VESDA-E aspiration smoke detector B200S-LF-IV: Ivory, low-frequency version of B200S.
with LED display, single pipe, covers up to 10,760 square feet. See
B200SR-WH: White intelligent programmable sounder base,
74-5216. UL/ULC Listed.
Temporal 3 or Continuous tone. For retrofit installations replacing
VEU-A00-HON: Intelligent VESDA-E aspiration smoke detector B501BH series bases. See 85-3043. ULC: B200SRA-WH.
with LED display, 4 pipes, covers up to 69,965 square feet. See 74-
B200SR-IV: Ivory intelligent programmable sounder base,
5217. UL/ULC Listed.
Temporal 3 or Continuous tone. For retrofit installations replacing
VEU-A10-HON: Intelligent VESDA-E aspiration smoke detector B501BH series bases. ULC: B200SRA-IV.
with LED and LCD display, 4 pipes, covers up to 69,965 square feet.
B200SR-LF-WH: White, low-frequency version of B200SR. See 85-
See DN-61034. UL/ULC Listed.
3043.
VEA-040-A00-HON: Intelligent VESDA-E aspiration with LED
B200SR-LF-IV: Ivory, low-frequency version of B200SR.
display, 40 point-addressable detection points. Covers 36,000
square feet. See 74-5218. UL/ULC Listed. TC809A1059(CDN): FlashScan monitor module. See 74-3993.
TC809D1004(CDN): FlashScan dual monitor module. See 74-
3993.

Page 6 of 9 — 74-4034-16 • 9/14/2022


TC841A1000(CDN): FlashScan two-wire detector monitor module. CHS-4L: Standard Chassis, Low Profile. Used in rows 1 through 4.
See 74-3993. Commonly used for AA series amplifiers.
TC809B1008(CDN): FlashScan miniature monitor module. See 74- CHS-4N: Standard Chassis, High Profile. Used in rows 1 through 4.
3993. Commonly used for APS-6R power supplies and other peripherals
TC809C1004: FlashScan 4-20 mA protocol monitor module. such as NCMs, LCMs, etc.

TC810N1013(CDN): FlashScan control module. See 74-3995. CHS-6: Chassis used with the XP6 and XP10 Multi-Modules.
Mounts up to six modules in any XLS-CAB-4 series row.
TC810S1000(CDN): FlashScan releasing control module. See 74-
5068. XLS-LBB: Battery Enclosure, Black. Holds two 60 AH batteries or
one 100 AH battery.
TC810T1000(CDN): Firephone Telephone Module connects a
remote firefighter telephone to a centralized telephone console. XLS-LBBR: Battery Enclosure, Red. Holds two 60 AH batteries or
Reports status to panel. Wiring to jacks and handsets is supervised. one 100 AH battery.
See 74-4077. BACKBOXES
TC810R1024(CDN): FlashScan relay module. See 74-3995. XLS-ABF-1B Annunciator Flush Box
TC822A1010(CDN): FlashScan dual monitor/dual relay module. XLS-ABF-1DB Annunciator Flush Box with Door.
See 74-5104.
XLS-ABF-2B Annunciator Flush Box
S464G1007: Manual pull station, addressable (CLIP/FlashScan).
See 74-3365. XLS-ABF-4B Annunciator Flush Box

XLS-MPS series: Manual pull stations, addressable and XLS-ABS-1TB Annunciator Surface Box
conventional. ULC listed; for use in Canada only. See 74-5090 and BB-100: Battery Enclosure. Holds up to two 100 AH batteries.
85C-3127. BB-200: Battery Enclosure. Stores up to 200 AH batteries.
TC811A1006/TC811A1014: Isolator module. See 74-4555. SEISKIT-CAB: Seismic mounting kit. Required for seismic-certified
ISO-6(A): Six fault isolator module. See 74-5181. applications with XLS3000 and other equipment mounted in
XP6-C(A): FlashScan six-circuit supervised control module. See 85- XLS-CAB-4 Series Enclosures. Includes battery bracket for two 26
3069. AH batteries.

XP6-MA(A): FlashScan six-zone interface module; connects SEISKIT-LBB: Seismic kit for the XLS-LBB. Includes battery bracket
intelligent alarm system to two-wire conventional detection zone. for two 55 AH batteries.
See 85-3070. XLS-ABS-2D Annunciator Surface Box
XP6-R(A): FlashScan six-relay (Form-C) control module. See 85- XLS-ABS-4D Annunciator Surface Box
3071. XLS-LSP, XLS-LSPA, XLS-SSP: FS90 retrofit kit components. See
XP10-M(A): FlashScan ten-input monitor module. See 85-3068. 74-5145.

ENCLOSURES, CHASSIS, AND DRESS PLATES AUDIO VISUAL DEVICES (RECOMMENDED)


XLS-CAB-4 Series Enclosure: XLS3000 mounts in a standard CAB- L-Series: Replacement for SpectrAlert® Advance wall and ceiling
4 Series enclosure. Backbox and door ordered separately; requires devices.
BP2-4 battery plate. A trim ring option is available for semi-flush
P2 and P4 Series: SpectrAlert Advance Wall Horn/Strobes. See 85-
mounting. See 85-3002.
0304 or 85C-0304 (Canada).
EQ Series Cabinets: EQ series cabinets will house amplifiers, power CH Series: SpectrAlert Advance Wall Chimes. See 85-0306 or 85C-
supplies, battery chargers and control modules. EQ cabinets are 0306 (Canada).
available in three sizes, “B” through “D”. See 85-3110.
SP2 Series: SpectrAlert Wall Speaker/Strobes, Wall Mount. See 85-
CHS-M3: Chassis for XLS3000 FACP control panel for all 0302.
applications unless the XLS-DVC-EM is used with firefighter's
telephones. Mounts in the top row of a XLS-CAB-4 series enclosure. SP2C Series: SpectrAlert Ceiling Speaker/Strobes, Ceiling Mount.
See 85-3101.
CA-2: Chassis for XLS3000 FACP control panel when XLS-DVC-EM
is used with firefighter's telephone. Mounts in the top two rows of a SP200 Series: SpectrAlert Speakers. See 85-0301.
XLS-CAB-4 series enclosure. See 74-4033. PA400 Series: SpectrAlert PA400 Series Mini Sounders. See 85-
DP-DISP: Display dress plate. Used whenever a CHS-M3 is used. 3083.
Covers the top row of a XLS-CAB-4 series enclosure. PF24V Series: Exit Point Directional Sounder. Used to mark
ADP-4B: Annunciator dress plate. Mounts in rows 2, 3 or 4 of a XLS- perimeter exits. See 85-3059.
CAB-4 series enclosure. Used with ACS series annunciators. SSM Series: Standard Fire Alarm Bells. See 85-3107.
BMP-1: Cover Plate. Used with the DP-DISP or ADP-4B whenever
an annunciator position is unused and needs to be covered.
MISCELLANEOUS
R-10, R-20, EOLR Series: Multi-Voltage conventional relays, UL
DP-1B: Solid Blank plate. Used to cover rows 2, 3 or 4. Used when
Fire rated. Used for a variety of fire applications. See 85-3111.
the installed equipment does not require user interaction (such as
audio amplifiers). FM Series: FM Series Magnetic Door Holders. See 85-3095.
BP2-4: Battery Plate. Covers the battery row. One required for each IPDACT-2/2UD Internet Monitoring Module: Connects to primary
XLS3000 system.(Existing XLS-BP2-4 may be used in retrofits.) and secondary DACT telephone output ports for internet

Page 7 of 9 — 74-4034-16 • 9/14/2022


communications over customer-provided Ethernet connection.
Requires compatible Teldat VisorALARM Central Station Receiver.
Can use DHCP or static IP. See 74-5097.
IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting
an IPDACT-2 onto the panel chassis or CHS-4 series chassis. Use
IPENC for external mounting applications.
IPSPLT: Y-adapter option allow connection of both panel dialer
outputs to one IPDACT-2 cable input.
IPENC: External enclosure for IPDACT, includes IPBRKT mounting
bracket; Red; for black, order IPENC-B.
HWF2V-COM: LTE Digital Cellular Fire Alarm Communicator and
Internet Panel, Verizon LTE / IP. Provides selectable configurable
paths: cellular only, IP only, or IP primary with cellular backup.
Connects to the primary and secondary ports of a DACT. For
Canadian applications order IPGSM-4GC. See DH-62010.
HWF2A-COM: LTE Digital Cellular Fire Alarm Communicator and
Internet Panel, AT&T LTE / IP. Provides selectable configurable
paths: cellular only, IP only, or IP primary with cellular backup.
Connects to the primary and secondary ports of a DACT. For
Canadian applications order IPGSM-4GC. See DH-62010.
Note: For other options including compatibility with retrofit
equipment, refer to the panel's installation manual, the SLC manual,
and the Device Compatibility Document.

AGENCY LISTINGS AND APPROVALS


The file number(s) below reference the specific listings for the
equipment in this document. In some cases, certain modules or
applications may not be listed by certain approval agencies, or
listing may be in process. Consult Honeywell for latest listing status.
• UL Listed: S470.
• Fire Dept. of New York: COA#6100, #6126.
• CSFM: 7165-1130:0256 (Commercial).
• FM Approved.
• FM6320 Approved. Class 6320 for Gas Detection.
• City of Chicago.
• City of Denver.
• Singapore Productivity and Standards Board (PSB).
• CCCF listed.

STANDARDS
The XLS3000 Intelligent Addressable Fire Alarm is designed to
comply with the following standards:
• NFPA 72 Local, Auxiliary, Remote Station, Proprietary, and Emergency
Voice/Alarm Fire System Requirements.
• Underwriters Laboratories Standard UL 864, 10th edition (Control
Units and Accessories for Fire Alarm Systems)
• Underwriters Laboratories Standard UL 2610 (Commercial Premises
Security Alarm Units and Systems).
• Underwriters Laboratories Standard UL 2572 (Mass Notification
Systems). (XLS3000 version 20 or higher)
• International Building Code IBC 2013, IBC 2009, IBC 2006, IBC 2003,
IBC 2000 (Seismic).
• California Building Code CBC 2007 (Seismic)
• ULC-S527-11 Standard for the Installation of Fire Alarm Systems.

Page 8 of 9 — 74-4034-16 • 9/14/2022


XLS3000 TECHNICAL SPECIFICATIONS
SYSTEM CAPACITY PHYSICAL SPECIFICATIONS
• Intelligent Signaling Line Circuits: 1 Temperature Ratings: Ambient: 32°F to EBI™ is a trademark; and
expandable to 10 120°F (0° to 49°C). Honeywell®, Acclimate®,
• Intelligent detectors: 159 per loop
Humidity Ratings: 10 to 93% RH, non- FlashScan®, SWIFT®, System
• Addressable monitor/control modules: 159 Sensor®, VeriFire® Tools, and VIEW®
condensing.
per loop
are registered trademarks of
• Programmable software zones: over 2000 SHIPPING WEIGHT
• ACS annunciators per XLS3000-CPU: Honeywell International Inc
XLS3000-CPUD: 5.95 lb (2.70 kg).
32 address x 64 or 96 points
XLS3000-CPUND: 2.90 lb (1.32 kg). All rights reserved. Unauthorized
Note: The XLS3000-CPU can support up to
use of this document is strictly
96 annunciator address points per ACM- TEMPERATURE AND HUMIDITY prohibited. This document is not
24AT/-48A. RANGES
intended to be used for installation
This system meets NFPA requirements for
ELECTRICAL SPECIFICATIONS purposes. We try to keep our
operation at 0 – 49°C/32 – 120°F and at a
Model: XLS3000 Intelligent Addressable relative humidity 93% ± 2% RH product information up-to-date and
Fire Alarm System (noncondensing) at 32°C ± 2°C (90°F ± accurate. We cannot cover all
3°F). However, the useful life of the system's specific applications or anticipate
PRIMARY INPUT POWER:
standby batteries and the electronic all requirements. All specifications
AMPS-24: 110-120 VAC, 50/60 Hz, 4.5 A components may be adversely affected by are subject to change without
maximum. extreme temperature ranges and humidity.
Therefore, it is recommended that this
notice.
AMPS-24E: 240 VAC, 50/60 Hz, 2.25 A
maximum. system and its peripherals be installed in an
environment with a normal room
Country of origin: USA
DC OUTPUT: temperature of 15 – 27°C/60 – 80°F.
24 VDC: Up to 4.5 A
5 VDC: Up to 1.0 A.
CURRENT DRAW (STANDBY/ALARM):
XLS3000-CPUD board: 0.340 A.
XLS3000-CPUND board: 0.120 A.
LCM-320: 0.130 A.
LEM-320: 0.100 A.
AMPS-24(E)*: 0.13 A.
(Draws power from secondary power source
only.)
Note: See AMPS-24(E) Manual 51907 for a
complete current draw calculation sheet
and details of input and output values.
Total Output Power: 24V, 4.5 A in alarm.

Honeywell Building Technologies


715 Peachtree Street NE
Atlanta, GA 30308
800.345.6770 74-4034-16 | 09/22