How can i make a code for display reading on lcd of energy meter by
OBIS Code using Nodemcu. Can you suggest or link to me for making
code for Secure meter?
Kurumi 2 years 3 months ago
Hi,
Hi,
The example reads the clock object. Find //Read clock.
It also prints date and time for the serial port using GXTRACE.
You need to add register objects in the same way as the clock object has been
added.
The problem at the moment is that one of your settings is different than the me-
ter expects.
Try to connect with GXDLMSDirector for your meter. It will help you to get a
better idea of DLMS meters.
BR,
Mikko
ayushshriwastav 2 years 3 months ago
Hi,
Hi,
Thanks sir for reply. My question is not that use gxtrace or com_AllObject. My
question is that what should i write read value in gxtrace or com_retAllObject
and How should i write read value in gxtrace.?
for example, Can i write syntax in void loop() in Arduindo in given below-
ret = gxtrace("1.0.99.1.0.255") or not? please tell me syntax to read value of regis-
ter and clock in void loop()?
Thanks Sir,
Kurumi 2 years 3 months ago
Hi,
Hi,
gxtrace is send to write a trace. You don't use it for the communication. You can
think that gxtrace equals Console.WriteLine. It's used to print the value, not for
the communication.
Check this. It will read the date and time from the clock object and then write
the content of the clock object for the meter.
//Read clock
gxClock clock1;
cosem_init(BASE(clock1), DLMS_OBJECT_TYPE_CLOCK, "0.0.1.0.0.255");
com_read(BASE(clock1), 3);
com_read(BASE(clock1), 2);
obj_toString(BASE(clock1), &data);
GXTRACE(GET_STR_FROM_EEPROM("Clock"), data);
obj_clear(BASE(clock1));
free(data);
BR,
Mikko
ayushshriwastav 2 years 3 months ago
Hi,
Hi,
Thanks for replying sir, How can i read value of Register and Extended Register
in void loop() function in Arduino? What is syntax of Register and Extended reg-
ister in void loop() function?
Thanks sir
Kurumi 2 years 3 months ago
Hi,
Hi,
Add values that you want to read under the clock object. Something like this:
//Read register
gxRegister reg1;
cosem_init(BASE(reg1), DLMS_OBJECT_TYPE_REGISTER,
"YOUR_OBIS_CODE");
com_read(BASE(reg1), 3);
com_read(BASE(reg1), 2);
obj_toString(BASE(reg1), &data);
GXTRACE(GET_STR_FROM_EEPROM("Register"), data);
obj_clear(BASE(reg1));
free(data);
BR,
Mikko
ayushshriwastav 2 years 3 months ago
Hi,
Hi,
Thank you so much for replying sir . How can i find InvocationCounter for
Secure Meter?
Please tell me about InvocationCounter for Secure meter? How can I find it and
What is role of Invocation Counter in DLMS Meter?
Thank you sir
Kurumi 2 years 3 months ago
Hi,
Hi,
When you connect to the meter there should be an Invocation Counter data ob-
ject. It's used to improve security, but all meters don't use it.
BR,
Mikko
ayushshriwastav 2 years 3 months ago
Hi,
Hi,
I am very happy to hear for reply sir , thank you so much sir. If Some meter don't
use Invocation Counter then What should i write in " ret =
com_readAllObjects("0.0.43.1.0.255") " in the void loop()
Kurumi 2 years 3 months ago
Hi,
Hi,
Set it NULL if you don't want to use Invocation Counter.
com_readAllObjects(NULL);
BR,
Mikko
ayushshriwastav 2 years 3 months ago
Hi,
Hi,
Thanks for replying sir. I have found new error in NodeMCU Board in Arduino
IDE when clock and register define in void loop() function in given below. How
can I solve this sir?
Arduino: 1.8.18 (Windows 10), Board: "NodeMCU 1.0 (ESP-12E Module), 80 MHz,
Flash, Disabled (new aborts on oom), Disabled, All SSL ciphers (most compatible),
32KB cache + 32KB IRAM (balanced), Use pgm_read macros for
IRAM/PROGMEM, 4MB (FS:2MB OTA:~1019KB), 2, v2 Lower Memory, Disabled,
None, Only Sketch, 115200"
Kurumi 2 years 3 months ago
Hi,
Hi,
You need to define data variable like this:
char* data = NULL;
BR,
Mikko
ayushshriwastav 2 years 3 months ago
Hi,
Hi,
Thank you so much sir. It is working perfectly and i did make it Global Variable
char* data = NULL;
I have some question now that if i want to read more values of Register for ex-
ample reg2, reg3, reg4 and reg5 etc. So what will syntax be written in void loop()
function for reg2,reg3,reg4 etc??
Kurumi 2 years 3 months ago
Hi,
Hi,
Check my answer:
https://www.gurux.fi/comment/25325#comment-25325
BR,
Mikko
ayushshriwastav 2 years 3 months ago
Hi,
Hi,
Thanks for reply sir. I am receiving this error again after convert object to string
function obj_toString() in void loop() function in arduino ide in given below.
Where am i going wrong ? Please tell me real solution.
Kurumi 2 years 3 months ago
Hi,
Hi,
It's a little hard to say from your pics, but you need to set data to NULL after
free.
free(data);
data = NULL;
BR,
Mikko
ayushshriwastav 2 years 3 months ago
Hi,
Hi,
Thanks for replying sir. I am very happy that you are guiding well sir. I am at-
taching code of void loop() function of client.ino in given below - and please tell
me this is Right or Wrong?
void loop()
int ret;
// Read the clock
gxClock clock1;
if (millis() - runTime > 5000)
runTime = millis();
GXTRACE(GET_STR_FROM_EEPROM("Start reading"), NULL);
//TODO: Change logical name of the frame counter if it's used.
ret = com_readAllObjects(1.0..43.1.0.255);
com_close();
Kurumi 2 years 2 months ago
Hi,
Hi,
It looks correct to me.
BR,
Mikko
ayushshriwastav 2 years 2 months ago
Hi,
Hi,
Thanks for replying sir. Very nice responsive talking. I have added more register
whose name is reg2,reg3,reg4 in given below code. what is this correct code or
not because i am taking register value in same time and declare global variable
char* data = NULL; So please brief explain how is storing reg1,reg2,reg3 and
reg4 in data in same time? And please tell sir this code is correct or not in given
below-
client.ino
int ret;
// Read the clock
gxClock clock1;
//Read the Register
gxRegister reg1;
gxRegister reg2;
gxRegister reg3;
gxRegister reg4;
if (millis() - runTime > 5000)
Kurumi 2 years 2 months ago
Hi,
Hi,
This is the correct way to do it. You aren't reading the values with the same re-
quest. You can use readList to read multiple values with one request, but all the
meters don't support it.
BR,
Mikko
ayushshriwastav 2 years 2 months ago
Hi,
Hi,
Thanks for reply sir, Can you please suggest and give syntax me How can use
readList to read multiple values in code?
And also brief tell sir if meter don't support it then what should be do for it?
Kurumi 2 years 2 months ago
Hi,
Hi,
com_readScalerAndUnits do what you want to do.
https://github.com/Gurux/GuruxDLMS.c/blob/c65175efc8917f0ee3a7eb340ac4
e…
If that is not supported then you need to read objects one by one as you do now.
BR,
Mikko
ayushshriwastav 2 years 2 months ago
Hi,
Hi,
Very thank you so much. Very nice talking and I am very happy that you are very
helpful sir. Can you please tell how can read all value in
com_readScalerAndUnits()? Please can you write a syntax to read all value in
com_readScalerAndUnits().
Kurumi 2 years 2 months ago
Hi,
Hi,
I believe that you don't want to read all values. It's taking a long time, but this
does it.
https://github.com/Gurux/GuruxDLMS.c/blob/c65175efc8917f0ee3a7eb340ac4
e…
BR,
Mikko
Kurumi 2 years 2 months ago
Hi,
Hi,
I believe that you don't want to read all values. It's taking a long time, but this
does it.
https://github.com/Gurux/GuruxDLMS.c/blob/c65175efc8917f0ee3a7eb340ac4
e…
BR,
Mikko
ayushshriwastav 2 years 1 month ago
Hi, Thank you, But i am not…
Hi,
Thanks for helping but i didn,t get ouput. Sure, I will find.
1 2
Log in or register to post comments
Username
Password
Log in
Create new account
Reset your password
Latest Releases
Mon, 03/10/2025 - 09:21
gurux.dlms.cpp 20250310.1
Thu, 03/06/2025 - 08:27
Gurux.DLMS.Net 9.0.2503.0601
Wed, 03/05/2025 - 13:07
gurux.dlms.cpp 20250305.1
Wed, 03/05/2025 - 10:11
Gurux.DLMS.Net 9.0.2503.0501
Mon, 03/03/2025 - 09:09
gurux.dlms.c 9.0.2503.0301
New forum topics
Wrong SetRequest after latest update
How to use object methods?
SL7000 AC VOLTAGE L1-L2
CSR Invalid Counter
Parse meter's push data
More
Who's new
D@faizan4321
DarrekonTrure
Charleseton
GictorGrala
Wayneimach
RSS feed
Privacy FAQ GXDN Issues Contact