0% found this document useful (0 votes)
13 views

V275

The document provides technical specifications for the V275C2 generator, including engine and alternator details, dimensions, power ratings, and control panel options. It outlines the generator's maximum power outputs, fuel consumption rates, and emissions data, along with descriptions of the TELYS and KERYS control panels. Additionally, it notes that the document is not contractual and subject to changes by the SDMO company.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views

V275

The document provides technical specifications for the V275C2 generator, including engine and alternator details, dimensions, power ratings, and control panel options. It outlines the generator's maximum power outputs, fuel consumption rates, and emissions data, along with descriptions of the TELYS and KERYS control panels. Additionally, it notes that the document is not contractual and subject to changes by the SDMO company.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

V275C2

Engine type TAD734GE


Alternator type LSA462L6

GENERAL CHARACTERISTICS
Frequency (Hz) 50
Reference voltage (V) T51A2
Max power ESP (kVA) 275
Max power ESP (kWe) 220
Max power PRP (kVA) 250
Max power PRP (kWe) 200
Intensity (A) 397
Standard Control Panel TELYS
Optional control panel KERYS

DIMENSIONS AND NOISE LEVELS


DIMENSIONS COMPACT VERSION
Length (mm) 2900
Width (mm) 1300
Height (mm) 1590
Dry weight (kg) 2200
Tank capacity (L) 390
DESCRIPTIVE
Electronic governor
Mechanically welded chassis with antivibration DIMENSIONS SOUNDPROOFED VERSION
suspension Canopy M227
Main line circuit breaker Length (mm). 4004
Radiator for wiring temperature of 48/50°C max with
mechanical fan Width (mm). 1380
Protective grille for fan and rotating parts Height (mm). 2145
9 dB(A) silencer supplied separately Dry weight (kg). 3130
Charger DC starting battery with electrolyte Tank capacity (L). 390
24 V charge alternator and starter Acoustic pressure level @1m in dB(A) 77.8
Delivered with oil and coolant -30°C Sound power level guaranteed (Lwa) 96
Manual for use and installation

POWERS
ESP PRP
Voltage Standby Amps
kWe kVA kWe kVA
POWER DEFINITION
PRP : Prime Power is available for an unlimited number 415/240 211 264 192 240 367
of annual operating hours in variable load applications, in 400/230 220 275 200 250 397
accordance with ISO 8528-1.
380/220 220 275 200 250 418
ESP : The standby power rating is applicable for 240 TRI 211 264 192 240 635
supplying emergency power in variable load applications in 230 TRI 220 275 200 250 690
accordance with ISO 8528-1. 220 TRI 220 275 200 250 722
Overload is not allowed.
200/115 220 275 200 250 794

STANDARD TERMS OF USE


27°C/40°C Air Intlet Temp.
1000 m A.S.L.
30% relative humidity.

This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to
improve the quality of its products.
V275C2
TECHNICAL SPECIFICATIONS

GENERAL ENGINE DATAS EXHAUST


VOLVO Exhaust gas temperature (°C) 550
TAD734GE ,
Engine model Exhaust gas flow (L/s) 557
4-temps, TURBO ,
AIR/AIR 6 X Max. exhaust back pressure (mm EC) 750
Cylinder arrangement L
Displacement (C.I.) 7.15
FUEL
Bore (mm) x Stroke (mm) 108 x 130
Consumption @ 110% load (L/h) 59.6
Compression ratio 17.1
Consumption @ 100% load (L/h) 53.4
Speed (RPM) 1500
Consumption @ 75% load (L/h) 42.6
Pistons speed (m/s) 6.5
Maximum stand-by power at rated Consumption @ 50% load (L/h) 30.5
241
RPM (kW) Maximum fuel pump flow (L/h) 300
Frequency regulation (%) 0.5
BMEP (bar) 24.18
OIL
Governor type ELEC
Oil capacity (L) 29
Min. oil pressure (bar) 1
COOLING SYSTEM
Max. oil pressure (bar) 4.5
Radiator & Engine capacity (L) N/A
Oil consumption 100% load (L/h) 0.01
Max water temperature (°C) 103
Carter oil capacity (L) 24
Outlet water temperature (°C) 93
Fan power (kW) 9.2
HEAT BALANCE
Fan air flow w/o restriction (m3/s) 4.8
Available restriction on air flow (mm Heat rejection to exhaust (kW) 177
20
EC) Radiated heat to ambiant (kW) 26
Type of coolant GLYCOL Haet rejection to coolant (kW) 129
Thermostat (°C) 83-95

AIR INTAKE
EMISSIONS Max. intake restriction (mm EC) 300
Emission PM (g/kW.h) 0.05 Intake air flow (L/s) 272
Emission CO (g/kW.h) 0.35
Emission HCNOx (g/kWh) N/A
Emission HC (g/kW.h) 0.08

This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to
improve the quality of its products.
V275C2
ALTERNATOR SPECIFICATIONS

GENERAL DATAS OTHER DATAS


Alternator brand LEROY SOMER Continuous Nominal Rating 40°C (kVA) 250
Alternator type LSA462L6 Standby Rating 27°C (kVA) 275
Number of phase 3 Efficiencies 4/4 load (%) 92.4
Power factor (Cos Phi) 0.8 Air flow (m3/s) 0.43
Altitude (m) 0-1000 Short circuit ratio (Kcc) 0.41
Overspeed (rpm) 2250 Direct axis synchro reactance unsaturated (Xd) (%) 327
Number of pole 4 Quadra axis synchro reactance unsaturated (Xq) (%) 196
Excitation system SHUNT Open circuit time constant (T'do) (ms) 2105
Insulation class / T° class, continuous Direct axis transcient reactance saturated (X'd) (%) 15.5
H / H-125
40°C
Short circuit transcient time constant (T'd) (ms) 100
Regulation R230
Direct axis subtranscient reactance saturated (X''d)
Harmonic factor, no load TGH/THC <2.5 9.3
(%)
Wave form : NEMA=TIF-(TGH/THC) <50 Subtranscient time constant (T"d) (ms) 10
Wave form : CEI=FHT-(TGH/THC) <2 Quadra axis subtranscient reactance saturated (X"q)
11.5
(%)
Number of bearing 1
Zero sequence reactance unsaturated (Xo) (%) 0.7
Coupling DIRECT
Negative sequence reactance saturated (X2) (%) 10.4
Voltage regulation at established rating
0.5 Armature time constant (Ta) (ms) 15
(%)
Recovery time (Delta U = 20% 500 No load excitation current (io) (A) 1
transcient) (ms)
Full load excitation current (ic) (A) 4
Full load excitation voltage (uc) (V) 34
Recovery time (Delta U = 20% transcient) (ms) 500
Engine start (Delta U = 20% perm. or 50% trans.)
462
(kVA)
Transcient dip (4/4 load) - PF : 0,8 AR (%) 15.9
No load losses (W) 3690
Heat rejection (W) 16400

DIMENSIONS AND NOISE LEVELS


CONTAINMENT
Canopy M227 DW
Length (mm). 4056
Width (mm). 1380
Height (mm). 2340
Dry weight (kg). 3850
Tank capacity (L). 950
Acoustic pressure level @1m in dB(A) 77.8
Sound power level guaranteed (Lwa) 96

This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to
improve the quality of its products.
V275C2
CONTROL PANEL

TELYS, ergonomic and user-friendly KERYS, coupling and adaptability

The highly versatile TELYS control unit is complex yet The KERYS control unit has been designed to fulfil
accessible, thanks to the particular attention paid to the specific requirements of professionals in terms of
optimising its ergonomics and ease of use. With its operating and monitoring generating sets. It therefore
large display screen, buttons and scroll wheel, it offers a wide range of functions.
places the accent on simplicity and communication. This control unit is fitted as standard to all generating
sets designed to be used for coupling and is offered
The TELYS offers the following functions: as an option across the rest of our range.
The KERYS can be built into the central console, fitted
Electrical measurements: voltmeter, frequency directly on the generating set, or in a separate cabinet,
meter, ammeter. to fulfil all the requirements for low and high output
power plants.
Engine parameters: working hours counter, oil
>The KERYS offers the following functions:
pressure, coolant temperature, fuel level, engine
speed, battery voltage.
Electrical measurements: voltmeter, frequency
meter, ammeter.
Alarms and faults: oil pressure, coolant
temperature, failure to start, overspeed, alternator
min./max., battery voltage min./max., emergency stop, Engine parameters: working hours counter, oil
fuel level. pressure, coolant temperature, fuel level, engine
speed, battery voltage.
Ergonomics: wheel for navigating around the
various menus. Alarms and faults: oil pressure, coolant
temperature, failure to start, overspeed, alternator
min./max., battery voltage min./max., emergency stop.
Communication: remote control and operation
software, USB connections, PC connection.
Additional functions: coupling, website,
For more information on the product and its options, diagnostic aid, assistance and maintenance, graphs
please refer to the sales documentation. and archiving, load impact management, 8 available
installation configurations, certification in line with
international standards.

For more information, please refer to the sales


documentation.
Additional specifications :Website, Troubleshooting,
Assistance and Maintenance, Plotting and logging,
Load impact, 8 configurations available, Compliance
with international standards...

This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to
improve the quality of its products.