0% found this document useful (0 votes)
44 views7 pages

Catalog Cap Dien Sulzer TECWATER-S1BN8-F-E-13

Uploaded by

Phong Phanhung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views7 pages

Catalog Cap Dien Sulzer TECWATER-S1BN8-F-E-13

Uploaded by

Phong Phanhung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

TECWATER

S1BN8-F 0,6/1 kV
Cable for Water Application

ENERGY
Technical Data

Trademark TECWATER
Type designation S1BN8-F
Specification Design and tests according to Prysmian specification
Approval VDE Certificate of Conformity with Factory Surveillance
Application For making connections to electrical equipment used in a waste-water
environment and subject to heavy mechanical stress, e.g. submersible pumps
in sewage disposal and treatment as well as submersible mixer.
Owing to the various (and frequently changing) substances of which the
contaminated water is made up, the cables may be used only in easily
accessible areas that can be inspected (installation depth of approximately 10
m, as customarily encountered in sewage water tanks).
These cables are also suitable for use in process water, cooling water, mine
surface water, rainwater and combined waste water. Under certain
circumstances they can be suitable for groundwater and seawater; it is possible
to impose less stringent specifications in terms of accessibility and inspection.
In such cases the cables can be used at depths up to 500 m.
If the water concerned is aggressive or composed of special substances, the
cables resistance properties should be examined.
These cables can be used indoors, outdoors, in explosion-hazard areas.
In other respects, DIN VDE 0298-300 / HD 516 applies

Electrical Rated voltage Uo/U = 0.6/1 kV


parameters Maximum permissible - Single-phase and three-phase AC operation
operation voltage of plant Line-Earth/ Line-Line 0.7/1.2 kV
and power system - DC operation
Line-Earth/ Line-Line 0.9/1.8 kV
AC test voltage 3 kV (test duration 15 min.)
Current-carrying capacity The values are valid for a multicore cable or three single-core cables in trefoil in
permanent operation with DC or AC with 50 up to 60 Hz at 30°C ambient
temperature, touching surface, three cores loaded.
In other respects, DIN VDE 0298-4 applies

Thermal Maximum permissible 90 °C


parameters operating temperature at
conductor
Maximum permissible short- 250 °C (max. 5 s)
circuit temperature at
conductor
Maximum permissible water 40 °C (At higher water temperatures, a shortened cable service life is to be
temperature expected.)
Minimum permissible when in motion - 25°C
temperatures during when stationary - 40°C
operation, laying,
transportation and storage

Mechanical Tensile strength Max. 15 N/mm², see selection table


parameters Minimum bending radii See selection table
Technical Data

Stability Water resistance Test according to DIN VDE 0282-16 (HD 22.16)
against other Resistance to oil Test according to DIN EN 60811-2-1
influences
Behaviour in case of fire Test according to DIN EN 60332-1-2
Design features

Conductor Copper, plain, finely stranded, Class 5 according to DIN VDE 0295 / IEC 60228
Insulation Ozone, water and weather resistant insulation compound, base EPR (Ethylene-Propylene
Rubber)
Core identification Power cables: Cores colored according to DIN VDE 0293-308:2003
Control cores: Cores light, printed with black numbers
Sheath 1 layer sheath: CPE special compound; water and oil resistant; colour: black
for all single core cables and multi core cables up to 5 cores and 6 mm²

2 layer sheath system:


Inner layer: EPR special compound; colour: blue
Outer layer: CPE special compound; water and oil resistant; colour: black
for all multi core cables starting with 10 mm² and all cables with more than 5 cores
Marking, example ~~"NNNNNNNN"~~TECWATER S1BN8-F 4G25 0,6/1 kV VDE-REG-NR~~

"NNNNNNNN" = order number


Selection and ordering data
Number of cores Order-No. Con- Overall Overall Minimum Minimum Approx. Tension Current- Short
and nominal ductor diameter diameter bending bending net force carrying Circuit
cross-sectional area diameter of cable of cable radii radii weight capacity, Current
(fixed (free for touching
instal- move- 1000 m surfaces,
lation) ment and at 30°C,
gui- entry) 3 cores
dance Min. Max. Max. loaded
value value value value 1s
mm² mm mm mm mm mm kg N A kA

TECWATER S1BN8-F, single-core design


1 X 1.5 5DH8 302 1,6 5.8 6.6 20 20 53 23 24 0.21
1 X 2.5 5DH8 303 2,0 6.3 7.0 21 21 65 38 31 0.36
1X4 5DH8 304 2,4 6.7 7.5 23 23 82 60 43 0.57
1X6 5DH8 305 2,9 7.2 8.0 24 32 103 90 55 0.86
1 X 10 5DH8 306 3,9 8.3 9.1 27 36 160 150 77 1.43
1 X 16 5DH8 307 5,0 9.1 10.1 30 40 210 240 103 2.29
1 X 25 5DH8 308 6,3 10.8 12.4 50 62 315 375 137 3.58
1 X 35 5DH8 309 7,5 12.3 13.9 56 70 421 525 169 5.01
1 X 50 5DH8 310 8,8 14.1 15.7 63 79 577 750 211 7.15
1 X 70 5DH8 311 10,6 16.3 18.3 73 92 808 1050 261 10.01
1 X 95 5DH8 312 12,2 18.8 20.3 81 102 1024 1425 314 13.59
1 X 120 5DH8 313 14,2 20.9 22.9 92 115 1314 1800 367 17.16
1 X 150 5DH8 314 16,0 23.2 25.2 101 126 1627 2250 422 21.45
1 X 185 5DH8 315 17,8 26.0 28.3 113 142 1982 2775 481 26.46
1 X 240 5DH8 316 20,3 28.9 31.2 125 156 2548 3600 571 34.32
1 X 300 5DH8 317 23,1 32.1 34.4 138 172 3151 4500 661 42.9
1 X 400 5DH8 318 26,5 36.3 38.6 154 193 4087 6000 762 57.2
1 X 500 5DH8 319 29,8 40,4 42,7 171 214 5160 7500 877 71.5

TECWATER S1BN8-F, two-core design, without PE conductor


2X1 5DH8 321 1,3 8.0 9.0 27 36 94 30 18 0.14
2 X 1.5 5DH8 322 1,6 8.6 9.6 29 38 111 45 23 0.21
2 X 2.5 5DH8 323 2,0 9.4 10.4 31 42 141 75 30 0.36
2X4 5DH8 324 2,4 10.2 11.8 35 47 182 120 41 0.57
2X6 5DH8 325 2,9 11.2 12.8 51 64 239 180 53 0.86
2 X 10 5DH8 326 3,9 15.0 17.0 68 85 420 300 74 1.43
2 X 16 5DH8 327 5,0 17.6 19.6 78 98 597 480 99 2.29
2 X 25 5DH8 328 6,3 21.6 23.6 94 118 890 750 131 3.58

TECWATER S1BN8-F, three-core design, with PE conductor


3G1 5DH8 331 1,3 8.4 9.5 28 38 104 45 18 0.14
3 G 1.5 5DH8 332 1,6 9.1 10.1 30 40 125 67 23 0.21
3 G 2.5 5DH8 333 2,0 9.6 11.2 34 45 162 112 30 0.36
3G4 5DH8 334 2,4 10.6 12.2 49 61 216 180 41 0.57
Selection and ordering data
Number of cores Order-No. Con- Overall Overall Minimum Minimum Approx. Tension Current- Short
and nominal ductor diameter diameter bending bending net force carrying Circuit
cross-sectional area diameter of cable of cable radii radii weight capacity, Current
(fixed (free for touching
instal- move- 1000 m surfaces,
lation) ment and at 30°C,
gui- entry) 3 cores
dance Min. Max. Max. loaded
value value value value 1s
mm² mm mm mm mm mm kg N A kA

TECWATER S1BN8-F, three-core design, without PE conductor


3X1 5DH8 381 1,3 8.4 9.5 28 38 104 45 18 0.14
3 X 1.5 5DH8 382 1,6 9.1 10.1 30 40 125 67 23 0.21
3 X 2.5 5DH8 383 2,0 9.6 11.2 34 45 162 112 30 0.36
3X4 5DH8 384 2,4 10.6 12.2 49 61 216 180 41 0.57
3X6 5DH8 385 2,9 12.1 13.7 55 69 292 270 53 0.86
3 X 10 5DH8 386 3,9 16.3 18.3 73 92 514 450 74 1.43
3 X 16 5DH8 387 5,0 19.1 21.1 84 106 740 720 99 2.29
3 X 25 5DH8 388 6,3 23.1 25.1 100 126 1094 1125 131 3.58
3 X 35 5DH8 389 7,5 25.6 28.6 114 143 1459 1575 162 5.01
3 X 50 5DH8 390 8,9 29.9 32.9 132 165 2018 2250 202 7.15
3 X 70 5DH8 391 10,7 35.4 38.4 154 192 2831 3150 250 10.01
3 X 95 5DH8 392 12,3 39.0 42.0 168 210 3547 4275 301 13.59
3 X 120 5DH8 393 14,3 44.4 47.4 190 237 4542 5400 352 17.16
3 X 150 5DH8 394 16,0 49,0 53,0 212 265 5627 6750 404 21.45
3 X 185 5DH8 395 17,7 54,2 58,2 233 291 6819 8325 461 26.46
3 X 240 5DH8 396 20,3 61,4 65,4 262 327 8645 10800 547 34.32

TECWATER S1BN8-F, four-core design, with PE conductor


4G1 5DH8 351 1,3 9,1 10,1 30 40 123 60 18 0,14
4 G 1.5 5DH8 352 1,6 9,5 11,1 33 44 148 90 23 0,21
4 G 2.5 5DH8 353 2,0 10,5 12,1 48 61 201 150 30 0,36
4G4 5DH8 354 2,4 11,8 13,4 54 67 276 140 41 0,57
4G6 5DH8 355 2,9 13,6 15,2 61 76 378 340 53 0,86
4 G 10 5DH8 356 3,9 17,8 19,8 79 99 464 600 74 1,43
4 G 16 5DH8 357 5,0 20,9 22,9 92 115 934 960 99 2,29
4 G 25 5DH8 358 6,3 25,3 28,3 113 142 1418 1500 131 3,58
4 G 35 5DH8 359 7,5 28,3 31,3 125 157 1877 2100 162 5,01
4 G 50 5DH8 360 8,9 33,2 36,2 145 181 2613 3000 202 7,15
4 G 70 5DH8 361 10,7 38,7 41,7 167 209 3638 4200 250 10,01
4 G 95 5DH8 362 12,3 43,7 47,7 191 239 4643 5700 301 13,59
4 G 120 5DH8 363 14,3 48,7 52,7 211 264 5833 7200 352 17,16
4 G 150 5DH8 364 16,0 54,5 58,5 234 293 7222 9000 404 21,45
4 G 185 5DH8 365 17,7 60,6 64,6 258 323 8830 11100 461 26,46
4 G 240 5DH8 366 20,3 68,2 72,2 289 361 11457 14400 547 34,32
4 G 300 5DH8 367 23,1 77,0 81,0 324 405 14368 18000 633 42,90

TECWATER S1BN8-F, five-core design, with PE conductor


5 G 1,5 5DH8 372 1,6 10,4 12,0 48 60 186 112 23 0,21
5 G 2,5 5DH8 373 2,0 11,6 13,2 53 66 250 187 30 0,36
5G4 5DH8 374 2,4 12,0 13,6 54 68 340 300 41 0,57
5G6 5DH8 375 2,9 14,6 15,3 61 77 480 450 53 0,86
5 G 10 5DH8 376 3,9 19,9 21,9 88 110 810 750 74 1,43
5 G 16 5DH8 377 5,0 23,2 25,2 101 126 1192 1200 99 2,29
5 G 25 5DH8 378 6,3 28,0 31,0 124 155 1810 1875 131 3,58
Selection and ordering data
Number of cores Order-No. Con- Overall Overall Minimum Minimum Approx. Tension Current- Short
and nominal ductor diameter diameter bending bending net force carrying Circuit
cross-sectional area diameter of cable of cable radii radii weight capacity, Current
(fixed (free for touching
instal- move- 1000 m surfaces,
lation) ment and at 30°C,
gui- entry) 3 cores
dance Min. Max. Max. loaded
value value value value 1s
mm² mm mm mm mm mm kg N A kA

TECWATER S1BN8-F, multi core design, with PE conductor, Control Cables


7 G 1,5 5DH8 403 1,6 12,9 14,5 58 73 276 157 23 0,21
8 G 1,5 5DH8 404 1,6 14,5 16,5 66 83 305 180 23 0,21
10 G 1,5 5DH8 406 1,6 15,6 17,6 70 88 376 225 23 0,21
11 G 1,5 5DH8 407 1,6 16,0 18,0 72 90 400 247 23 0,21
12 G 1,5 5DH8 408 1,6 16,0 18,0 72 90 413 270 23 0,21
7 G 2,5 5DH8 413 2,0 14,7 16,7 67 84 381 262 30 0,36
8 G 2,5 5DH8 414 2,0 16,3 18,3 73 92 410 300 30 0,36
10 G 2,5 5DH8 416 2,0 17,4 19,4 78 97 480 375 30 0,36
12 G 2,5 5DH8 418 2,0 17,9 19,9 80 100 555 450 30 0,36
Technical data, dimension and weights are subject to change.
PRYSMIAN Germany Version: 1.3 SL - Date: 2011-05-13

You might also like