MEMBRANE ELEMENT PMSW-400LF
Low Fouling & Low Pressure Drop
SPECIFICATIONS
Nominal Membrane Area 400 sq.ft
Permeate Flow: 9,000 gpd (34.1 m3/d)
Stabilized Salt Rejection: 99.8 %
Membrane Polymer: Polyamide Thin-Film Composite
Feed Spacer thickness: 34 mil (0.864 mm)
The stated performance is based on the following conditions:
32,000 ppm NaCl
800 psi (5.5 MPa) Applied Pressure
77 F (25 C) Operating Temperature
10% Permeate Recovery
pH Range 6.5-7.0
A
C
B FEED PERMEATE
CONCENTRATE
A, inches B, inches C, inches Weight, lbs.
(mm) (mm) (mm) (kg)
40.0 (1016) 7.89 (200) 1.125 (28.6) 36 (16.4)
OPERATING DATA
Maximum Applied Pressure: 1200 psig (8.27 MPa)
Free Chlorine Tolerance: < 0.1 ppm
Maximum Operating Temperature: 113 F (45 C)
Continuous pH Range (Cleaning): 2– 11 (1 - 13)
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater SDI (15 mins): 5.0
Maximum Feed Flow: 85 gpm (19.3 m3/h)
Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1
Maximum Pressure Drop: 15 psi
NOTICE:
PERMEATE FLOW FOR AN INDIVIDUAL ELEMENT MAY VARY + OR - 15 PERCENT. ALL MEMBRANE ELEMENTS HAVE A BRINE SEAL, INTERCONNECTOR, AND O-RINGS IN A SEALED
POLYETHYLENE PLASTIC BAG. USE GLYCERIN OR SILICON ONLY FOR LUBRICATION OF SEALS AND O-RINGS. ALWAYS AVOID STATIC PERMEATE BACKPRESSURE. WE OFFER DATA IN
GOOD FAITH BUT WITHOUT GUARANTEE. PLEASE REFER TO THE APPLICATION INFORMATION LITERATURE ENTITLED OPERATION GUIDELINES FOR MORE INFORMATION BEFORE
INSTALLING AND OPERATING THE ELEMENTS.
PERSALT MEMBRANES: 401 East Jackson Street Suite 2340, Tampa, FL 33602
Phone: (813) 803-6125 Fax: (813) 803-6126 – [email protected]