Infinity® Gamma XL Patient Monitor
Designed to support low- to mid-acuity patients, the Infinity
Gamma XL patient monitor provides a full set of the most
commonly used parameters – including ECG, arrhythmia
analysis, respiration, SpO2, pulse rate, temperature, and
noninvasive and invasive blood pressure.
MT-2054-2003
Patented Pick and Go® technology enables these monitors to provide continuous
surveillance, while eliminating the need to purchase separate transport monitors.
The Gamma XL monitor has a compact, user-friendly design. Seamless wired or
MT-8848-2006
wireless networking capabilities let you share and receive patient information for
better-informed decisions.
Infinity Gamma XL
FEATURES Scalable patient monitor that doubles
as a transport monitor.
– Provide monitoring versatility for any sub-acute care setting
– With Pick and Go, the need of separate monitors is eliminated.
– Works as a standalone patient monitor or connects to Infinity Network via Infinity Docking Station or wire-
less adapter for seamless wired to wireless networking
– Scales using software options
Monitoring Capabilities
Neonatal, pediatric and adult applications
TECHNICAL DATA
SUPPORTED PARAMETERS
ECG
Available leads 3-lead set, Leads: I, II, III
5-lead set, Leads: I, II, III, aVR, aVL, aVF,
V
6-lead set, Leads: I, II, III, aVR, aVL, aVF, V, V+
Measuring range 15 to 300 bpm
Accuracy ± 5 bpm or ± 2% (whichever is greater)
Frequency range (±3 dB) 0.5 Hz to 28 Hz (50 Hz)
0.5 Hz to 40 Hz (60 Hz)
02 | INFINITY GAMMA XL PATIENT MONITOR
CONTINUING TECHNICAL DATA
Mains filter or Notch filter 50 or 60 Hz
QRS Detection Range
QRS detection Amplitude: 0.5 - 5.0 mV
Duration: 70 - 120 ms (Adult and Pediatric), 40 - 120 ms (Neonatal)
Alarms User-selectable upper and lower limits
Pacer detection Leads: I, II or III
(adult/pediatric) Amplitude: ± 5 to ± 700 mV
Width (dp): 0.2 to 2.0 msec
Accessories 3-, 5- or 6-lead electrode set
ST Analysis (not intended for neonates)
Available leads With 2-lead ST option: Choice of any 2 available leads
Default leads II, V (if used with MultiMed® 5 or 6 lead)
ECG complex length 900 msec
Units of measure mm (default) or mV
Minimum number of beats One required in updated interval
Resolution ±0.1 mm/ ±0.01 mV
Accuracy < ±1 mm/ ±0.1 mV (RTI – referred to input)
Upper and lower ST alarms -15.0 mm to +15.0 mm in 0.1 mm increments
-1.50 mV to +1.50 mV in 0.01 mV increments
Isoelectric measurement point
Adjustment range Start of ECG complex to fiducial point
Default QRS onset – 28 msec
ST measurement point
Adjustment range Fiducial point to end of ECG complex
Default QRS offset + 80 msec
Arrhythmia Detection
Adult and Pediatric Yes
Neonatal No, only bradycardia is available as a low heart rate alarm in
neonatal mode
ARR Mode User Selectable; OFF, Basic or Advanced
Basic ARR (standard) Asystole, ventricular fibrillation, ventricular tachycardia, bradycardia,
and PVC/min parameter output.
Advanced ARR (option) Ventricular run, accelerated idioventricular rhythm, supra-ventricular
tachycardia, couplet, bigeminy, tachycardia, pause and artifact.
Respiration
Sensing lead II
Measuring method Impedance pneumography
Auxiliary current <10µA for any active electrode
Detection threshold 0.2Ω to 4.0Ω in manual mode (user adjustment)
0.2Ω to 1.5Ω in auto mode (automatic adjustment)
Measuring range 0 to 155 breaths/min
Accuracy ±1 breath/min or ±2% (whichever is greater)
Alarms User-selectable upper and lower respiration rate
INFINITY GAMMA XL PATIENT MONITOR | 03
Pulse Oximetry (SpO2)
SpO2 algorithm Masimo® SET® (Signal Extraction Technology)
Masimo provides the industry “gold standard” for motion tolerant
pulse oximetry technology as documented in Masimo’s peer reviewed
studies (www.masimo.com).
See Infinity Masimo SET SmartPod® datasheet for more detailed
specifications.
SpO2 algorithm Dräger’s OxiSure® SpO2
Dräger’s OxiSure SpO2
Connection MultiMed® pods (SpO2 port)
Displayed parameters Saturation (fraction of oxyhemoglobin to functional hemoglobin)
and pulse (rate and curve)
Measuring method Absorption-spectrophotometry
Pulse 30 to 250 bpm
Accuracy SpO2: 0 to 69% not specified
SpO2: 70 to 100% ±2%
(except Masimo® LNOP-Ear which is ±3.5%
and Nellcor™ DS100A which is ±3%)
Saturation accuracy range increases by ±1% for neonates
Pulse: ±3 bpm or ±3% (whichever is greater)
Alarms User-selectable upper and lower limits for SpO2 and pulse rate
Accessories Dräger-approved Masimo or Nellcor sensors
Dräger reusable SpO2 sensor (not intended for neonates).
Temperature
Displayed parameters Absolute temperature
Measuring range 0 to 50 °C
Accuracy Probe: ± 0.1 °C
System: ± 0.2 °C
Alarms User-selectable upper and lower limits
Accessories Dräger-approved core and skin probes
Noninvasive Blood Pressure (NBP)
Displayed parameters Systolic, Mean and Diastolic pressures
Measuring method Oscillometric utilizing step deflation
Modes of operation Manual (single measurement) or Interval
Interval times Off, 2, 2.5, 3-15 (increments of 1),30, 45, 60, 120, 180, 240 minutes
Heart rate measuring range 30 to 240 bpm
Pressure measuring range
Adult Systolic: 30 to 250 mmHg
Mean: 20 to 230 mmHg
Diastolic: 10 to 210 mmHg
Pediatric Systolic: 30 to 170 mmHg
Mean: 20 to 150 mmHg
Diastolic: 10 to 130 mmHg
Neonatal Systolic: 30 to 130 mmHg
Mean: 20 to 110 mmHg
Diastolic: 10 to 100 mmHg
04 | INFINITY GAMMA XL PATIENT MONITOR
CONTINUING TECHNICAL DATA
Cuff pressure
Default inflation pressure or after technical alarm
Adult 160 mmHg ± 10 mmHg
Pediatric 120 mmHg ± 10 mmHg
Neonatal 110 mmHg ± 10 mmHg
Inflation pressure after a valid measurement
Adult (Last Systolic +25 mmHg) ± 10 mmHg
Pediatric (Last Systolic +25 mmHg) ± 10 mmHg
Neonatal (Last Systolic +30 mmHg) ± 5 mmHg
Maximum inflation pressure
dult 265 mmHg ± 5 mmHg
A
Pediatric 180 mmHg ± 10 mmHg
Neonatal 142 mmHg ± 10 mmHg
Minimum inflation pressure
dult 110 mmHg ± 10 mmHg
A
Pediatric 90 mmHg ± 10 mmHg
Neonatal 70 mmHg ± 10 mmHg
Connector Quick-release connector with single airway
Invasive Blood Pressure (IBP)
Displays up to 2 pressures (with IBP option and Y-cable)
Measuring method Resistive strain gauge transducer
Display resolution 1 mmHg
Measuring range -50 to 400 mmHg
Frequency ranges DC to 16 Hz
Zero balance range ± 190 mmHg
Transducer specifications Dräger-approved transducers with a resistance of 300 to
2000Ω and an equivalent pressure sensitivity of 5µV/V/mmHg ± 10%
Accuracy ± 2 mmHg or ± 3%, whichever is greater, after successful zero and
calibration (exclusive of transducer)
IBP alarms User-selectable upper and lower limits for systolic, mean and
diastolic pressures
Accessories Dräger-approved pressure transducers
DISPLAY SPECIFICATIONS
Type Thin Film Transistor-Liquid Crystal Display Active Matrix (TFT-LCD)
Size 21 cm (8.4 in.) diagonal
Channels 4 standard
Viewing area 170.9 mm x 129.6 mm
Resolution 640 x 480 pixels
User Interface Rotary knob, easy-to-use menu structure and fixed keys
Alarms
Priorities 3; High (Life Threatening), Medium (Serious), Low (Advisory)
INFINITY GAMMA XL PATIENT MONITOR | 05
Connections
MultiMed cables, IBP, NBP Input, PodPort ( for optional etCO2 pod), USB ( for optional Masimo
SmartPod or Scio Four modules), Memory Card Slot, QRS sync output, and Infinity Docking Station,
or interface plate. Interface plate provides connection to external VGA or Scio Four modules, and RS232/
Alarm output/R50 Recorder. IDS provides connections to Scio module, power supply, alarm output, Infinity
network, R50 recorder, and VGA/RS232 output.
Infinity Network
Networking method Wireless or via Infinity Docking Station
Wireless encyption None, WEP, WPA2
Some connections are only accessible via the IDS connection, see individual product datasheets
for detailed information.
Physical Specifications
Cooling Convection (no fan)
Size H x W x D 215 x 301 x 131 mm (8.5 x 11.9 x 5.2 in.)
Weight without battery 3.32 kg (7.32 lbs.)
Information Management Capabilities
Data storage 24 hours
Data resolution 60 seconds
Trend tables 1-, 5-, 15-, 30- or 60-minute display formats
Trend graphs 1-, 2-, 4-, 8-, 12- or 24-hour display formats
Trend type Tabular and graphical tables and event recall (10 events)
Electrical Specifications
Monitor input voltage 11 to 14 V DC, 2.5A
Power consumption ≤52 watts (fully loaded)
Patient leakage current ≤10 μA
Protection class Internally powered (per IEC 60601-1) and for use with specified
Class 1 power supplies.
AC Power Adapter Requirements 100-120 VAC, 0.8A or 200-240 VAC, 0.4A
Frequency 50 to 60 Hz
Chassis leakage current <300 μA @ 110 V AC at 60 Hz
<500 μA @ 220 V AC at 50 Hz
BATTERY SPECIFICATIONS
Lead-acid battery
Battery capacity 75 minutes
Charging time 5.5 hours at 25 °C
Lithium-ion battery
Battery capacity 210 minutes in Bright Mode
240 minutes in Dim Mode
Charging time 8 hours at 25 °C
Battery capacity varies with parameter configuration.
Battery capacity is specified under the following conditions:
NBP measurement every 15 minutes, ECG and SpO2 connected, no etCO2 and running at 25 °C (77 °F)
Battery capacity may diminish after extended use.
06 | INFINITY GAMMA XL PATIENT MONITOR
CONTINUING TECHNICAL DATA
Environmental Requirements
Temperature range
perating 0 °C to 45 °C (32 °F to 113 °F)
O
Storage -20 °C to 50 °C (-4 °F to 122 °F)
Relative humidity
perating 10% to 95%, non-condensing
O
Storage 10% to 95% (with packaging)
Atmospheric pressure
perating 525 to 795 mmHg (70 to 106 kPa)
O
Storage 375 to 795 mmHg (50 to 106 kPa)
Standards
IEC 60601-1and applicable particular and collateral standards,
IEC 60601-1-2, Electromagnetic compatibility CISPR 11, Class B
ORDERING INFORMATION
Gamma XL Monitor MS18985
Note: Includes pod port. Invasive pressure is optional. (see software options)
Monitor AC Power Supply MS18508
Power Cables
Europe, CEE 7, 2.5 m 4321712
North America, 5-15A, 2.25 m 4321720
Switzerland, SEV 1 01 1, 2.25 m 1851691
Great Britain, BS 1363, 3 m 1851713
Australia, New Zealand, AS3112, 3 m 1851705
China, AS 3112, 3 m 1859714
Denmark, RoHS, 3 m 1868950
Brazil, RoHS, 3 m 1875523
Mounting
Infinity Docking Station (IDS) + Power Adapter kit 7265130
Provides mechanical mounting as well as interfaces for monitor’s electrical,
network, video, recorder, and RS-232 data export and serial communications.
Mounting Docking Station 4715319
For use in standalone configurations
Monitor Interface Plate 3376493
Provides connections to external VGA/Scio Four Modules,
and R50 recorder/RS232.
INFINITY GAMMA XL PATIENT MONITOR | 07
CONTINUING ORDERING INFORMATION
MultiMed Pods and Cables
Multi-parameter Cables to Monitor
3-, 5- or 6- lead wire ECG, impedance respiration, SpO2* and one temperature
MT-1816-2006
MultiMed Plus, 2.5 m MS20093
MultiMed Plus OR, 2.5 m MS20094
Supports integrated ESU filter for operating room environment.
Infinity Docking Station
MultiMed 5, 2.5 m 3368391
MultiMed 6, 2.5 m 5191221
NeoMed, 2.5 m 5590539
3-lead wire ECG, impedance respiration, one temperature and SpO2
(FiO2 not supported)
MultiMed or NeoMed Pole/Rail Mount MP00721
*SpO2 measurements are not available from the MultiMed pods and cables if you are using an alternate
source of SpO2
MT-1307-2005
SpO2 Pods
Masimo SET® SpO2 SmartPod® 1 kit MS16900
Pod SpO2 Masimo USB MS16358
Masimo SET SpO2 Pod
Software Options
Arrhythmia II 7487189
Dual IBP; includes 2 IBP channels MS15484
OxyCRG 5957480
Dual-lead ST-segment analysis 5594978
Scio® multigas connectivity MS13205
Wireless network support** 7487197
MT-1126-2007
**Wireless LAN PC card (MS25032), and access point installation is required
for wireless monitoring.
MultiMed Pod Hardware Options
PC memory data card 4718248
etCO2 and Anesthesia Gas Monitoring
etCO2 pod (Mainstream/Sidestream)1 5740738
Scio Four Modules1 6871810
Scio Four Oxi plus, Scio Four plus,
Scio Four Oxi and Scio Four modules
MT-8945-2006
Printing/Recording Options
R50 recorder1 5952630
R50N network recorder1* 5740068
etCO2 Pod Infinity Network laser printer (115 V)* 6556513
Infinity Network laser printer (220 V)* 6556539
*Requires connection to Infinity Network
1
Refer to individual module or pod datasheet for additional information.
08 | INFINITY GAMMA XL PATIENT MONITOR
90 51 998 | 07.14-2 | Communications & Sales Marketing | PP | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2014 Drägerwerk AG & Co. KGaA
Infinity, MultiMed, Pick and Go, and Scio are registered trademarks of Dräger.
Masimo and SET are registered trademarks of Masimo Corporation.
Nellcor is a trademark of Covidien AG or an affiliate.
HEADQUARTERS REGION EUROPE CENTRAL REGION MIDDLE EAST, AFRICA, REGION NORTH AMERICA
Drägerwerk AG & Co. KGaA AND EUROPE NORTH CENTRAL AND SOUTH AMERICA Draeger Medical, Inc.
Moislinger Allee 53–55 Dräger Medical GmbH Dräger Medical GmbH 3135 Quarry Road
23558 Lübeck, Germany Moislinger Allee 53–55 Branch Office Dubai Telford, PA 18969-1042, USA
23558 Lübeck, Germany Dubai Healthcare City, P.O. Box 505108 Tel +1 215 721 5400
www.draeger.com Tel +49 451 882 0 Dubai, United Arab Emirates Toll-free +1 800 437 2437
Fax +49 451 882 2080 Tel + 971 436 24 762 Fax +1 215 723 5935
[email protected] Fax + 971 436 24 761 [email protected]
[email protected]
REGION EUROPE SOUTH REGION ASIA / PACIFIC Manufacturer:
Dräger Médical S.A.S. Draeger Medical Draeger Medical Systems, Inc.
Parc de Haute South East Asia Pte Ltd Telford, PA 18969-1042, USA
Technologie d’Antony 2 25 International Business Park The quality management system at
25, rue Georges Besse #04-27/29 German Centre Draeger Medical Systems, Inc. is
92182 Antony Cedex, France Singapore 609916, Singapore certified according to ISO 13485,
Tel +33 1 46 11 56 00 Tel +65 6572 4388 ISO 9001 and Annex II.3 of Directive
Fax +33 1 40 96 97 20 Fax +65 6572 4399 93/42/EEC (Medical devices).
[email protected] [email protected]