EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002; A. GENERAL INSTRUCTIONS
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
B. MAIN FEATURES
EN61000-4-11: 1994.
& C. LAMP
2B
Harmonized Standard
D. HOW TO CONTROL THE UNIT
1. By universal DMX controller
EN60598-1: 2000+ALL:2000+A12:2002 2. Preprogrammed function
Safety of household and similar electrical appliances 3. By easy controller
Part 1 : General requirements
E. FIXTURE CLEANING
Downloaded from www.Manualslib.com manuals search engine
A. GENERAL INSTRUCTIONS E. FIXTURE CLEANING
Please read the enclosed instructions carefully as they include important points The cleaning of internal and external optical lenses and/or mirrors must be
about safety for the installation, usage and maintenance of the unit. carried out periodically to optimize light output. Cleaning frequency depends on the
• Please keep this booklet with the unit for future consultation. If you sell the unit to environment in which the fixture operates: damp, smoky or particularly dirty
another user, be sure that the new user also receives this instruction booklet thus surrounding can cause greater accumulation of dirt on the unit’s optics.
giving them the necessary information about the use and general warnings • Clean with a soft cloth using normal glass cleaning products.
regarding the unit. • Always dry the parts carefully.
• Before the initial start-up, please unpack and carefully check all components in • Clean the external optics at least once every 20 days. Clean the internal optics
case any damage may have occurred during shipping. at least every 30/60 days.
• Locate a suitable spot for your device where there is good ventilation. Also, make
sure that no ventilating fans or slots are blocked.
• Protect our environment! Please dispose of the packing boxes properly.
• The electrical work that is necessary for installation must be done by qualified
personnel.
3B
• Always remember to unplug the unit from the power mains before any service is
done. Do not open the unit, there are no serviceable parts inside.
• It is very important to ground the yellow/green conductor to earth in order to meet
regulations for safety.
• Check the surrounding area and make sure there are no flammable liquids, water
or metal objects that could enter the fixture. If a foreign object enters the unit,
immediately disconnect the main power. Also, place the fixture in a
well-ventilated room at about 15 cm from the walls.
• Do not touch any wires during operation, as high voltage might be hazardous.
• I n the event of serious operating problems, stop using the unit immediately. Never
try to repair the unit yourself. Repairs carried out by unqualified personnel can
lead to damage or malfunction. Please contact the nearest authorized Technical
Assistance Center. Always use genuine spare parts. For further requirements, contact the nearest authorized technical assistance center.
Downloaded from www.Manualslib.com manuals search engine
( 2 ) Preprogram functions B. MAIN FEATURES
• The unit can be linked together as master/slave in 4 or 8 channels and run by
built in preprogrammed chase sequences automatically or by sound activation. • Voltage:AC 110~120V 60Hz or AC 230/240/250V 50/60Hz
Please refer to dip switch setting table for how to set the dip switches to achieve • Bulb:JCR 15V 150W
master/slave linking. • The unit is a DMX512 compatible color changer. It features full DMX512 control,
• The first unit dip switch 10 must be on in master/slave mode 10 dichroic colors plus clear and shutter, accurate focus able optics system and
stepper motor with blackout and switch off the bulb feature. Fan cooled.
Unit Dip switches setting
• T hermal switch for overheat protection.
Master • It can be operated by DMX512 control or can be used as an individual unit
without a control.
Slave 1
• It can be linked together in master/slave combination units, as many as required
Slave 2 in 4 or 8 channels and run by built-in preprogrammed chase sequences
automatically or by sound activation through an internal microphone to create an
Slave 3
intelligent effect.
( 3 ) By easy controller • Please use a 3 pin XLR cable/plug when connecting them together.
4B
The easy remote control is used only in master/slave mode. By connecting • It features different preprogrammed chase patterns.
to the 1/4” microphone jack of the first unit, you will find that the remote control • Dimensions:265 x 140 x 160 mm
on the first unit will control all the other units for Stand by, Strobe/Next and • Weight:5.0 kg
Fast/Slow function.
1. STAND BY : blackout and switch off the bulb. C. LAMP
2. STROBE/NEXT : when the unit is in fast mode press the
button and keep pressed up, it will strobe by sound activation. JCR 15V 150W
If the unit is in slow mode, you can select the next color and • Always switch off the mains supply and never handle the lamp or luminaire when
next sequences. it is hot.
3. FAST/SLOW : when the led light off, it is in FAST mode. The • Do not touch the bulb with bare hands. If this does happen, clean the lamp with
unit change color by sound activation. If the led light on, it is denatured alcohol and wipe with a lint free cloth before installing.
in SLOW mode, you can select the next color by NEXT
button.
Downloaded from www.Manualslib.com manuals search engine
D. HOW TO CONTROL THE UNIT DMX512 CONFIGURATION
( 1 ) By universal DMX controller
DMX512 Leave Range 0 ~ 255 Channel Dip switches setting
The DMX512 is widely used in intelligent lighting control, with a maximum of
512 channels. 255 Fastest speed strobe Ch 01
• A DMX512 system requires a controller, lighting equipment and cable. These 224 Slowest speed strobe
Ch 02
are connected together in a “daisy chain” with the terminator at the end. The 192-223 Rainbow effect slow to fast
cable cannot be branched or split to a “Y” cable. 176-191 Pink Ch 03
• The terminator requires a 90-120 Ohm 1/4 Watt resistor soldered between two 160-175 Magenta
Ch 04
signal cables. 144-159 Light Blue
• The DMX512 uses a very high speed signal. Inadequate or damaged cables, 128-143 Light Green
bad solder joints or corroded connectors can easily distort the signal and shut 112-127 Orange
down the system. A reliable DMX512 system starts with good quality cables. 96-111 Amber
• Each lighting unit needs to have an address set to receive the data sent by the 80-95 Green
controller. The address number is between 0-511 (usually 0 & 1 are equal to 64-79 Blue
1). 48-63 Yellow
5B
• The end of the DMX512 system should be terminated to reduce signal errors. 32-47 Red
• 3 pin XLR connectors are more popular than 5 pin XLR. 16-31 White
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 00-15 Blackout
pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
• Start the address
1 2 3 4
How to address your DMX512 system:
1. Select the channels of DMX controller
2. Dip switches
Dip #1 #2 #3 #4 #5 #6 #7 #8 #9 #10
DMX512 120 ohm 1/4W
Value 1 2 4 8 16 32 64 128 256 M/S
COMMON
• Examples:
1 1
DMX +
3 3 Channel 1 : dip / on : #1 ( 1 )
2 2
DMX -
Termination reduces signal errors and to avoid signal
Channel 2 : dip / on : #2 ( 2 )
1
transmission problems and interference. It is always
advisable to connect a DMX terminal.
3 Channel 3 : dip / on : #1, #2 ( 1+2 = 3 )
2
(Resistance 120 ohm 1/4W) between pin2 (DMX-) and
pin3 (DMX+) of the last fixture.
Channel 4 : dip / on : #3 ( 4 )