Serenity 48V/3000W
High Efciency Rectier
Exicom's new telecom rectier Serenity 48V/3000W combines advanced design for reliability and an industrial
leading efciency of 96.0%. The single phase, hot pluggable fan cooled rectier provides outstanding power
density and come with optional integrated distribution cabinets giving customers exibility to meet higher power
demands in a tight spaces as per telecom requirements
Key Features: Applications:
High efficiency of 96.0% & high power Telecom: Cellular base station sites,
density with 12KW in 1U shelf LTE/WiMax,
Wide operating input voltage and Hub sites and central offices
temperature range
Smart Cities: Smart poles, surveillance etc.
Small and Large: Can support installations
from 3KW to 300KW
Power Utilities: Control and protection and
Hot Plugin and user friendly registration communication equipment
for easy maintenance
Railways: Signalling, communication
equipment and control & protection
Multi-application use
TUV and CE Compliance
Serenity 48V/3000W - Technical Specications
AC INPUT OTHER SPECIFICATIONS
Voltage 90 – 300V ac Operating - 40°C to +75°C, Linear derating
Temperature from 40°C onwards
Frequency 45-66Hz
Storage Temperature - 40°C to +85°C
Maximum Current 18.0A
Cooling Forced Air
THD <5%
Humidity: Operating 5% to 95% non-condensing
Power Factor Typical 0.99 Storage Upto 99% non- condensing
Quiescent Power < 15W typical Acoustic Noise Less than 55dB(A)
Off < 85 – 310V ac < Off MTBF >300.000 hrs.Telcordia SR-332
Self Protection upto 420V ac
Input Protection Auto Shut-off, Auto-restart 106x 50 x 360(mm)
Dimensions
Line & Neutral input fuses 4.1”x 1.9” x 14.2”
MOV transient protection IP rating IP20
Galvanic Isolation
Weight 2.2kg (4.8 lbs)
Input to Output 3000 V ac
Input to Ground 1500 V ac AC Input Abnormal
Output to Ground 500 V ac AC over / UnderVoltage
Rectifier OK /Fail
Communication Failure
DC OUTPUT Alarms Fan Fail
Output OVP
Voltage 54.0V; Adj: 42.0 - 58.0V Output Low Voltage
2 Phase Operation
Output Power 3,000W above 185 Vac
Temperature Shut Down
Maximum Current 62.5A at 48V Rectifier OK / Fail
AC Over / Under Voltage
Current Sharing +/-5% of max. current
Visual Indicator Output Over/Under Voltage
above 10% Load
Communication Fail
Fan Fail / Temp. Shut Down
Static Voltage regulation +/-0.5% from 10% - 100% load
Dynamic Voltage +/-5% for 10% - 90% load
Regulation APPLICABLE STANDARDS
Ripple Noise <300 mV p-p Electrical Safety EN 60950
30MHz bandwidth EMC EN 61000-6-1
<2mVrms psophometric EN 61000-6-2
EN 61000-6-4
Output Protection Over Voltage Shutdown Harmonics EN 61000-3-2
Overload Foldback EN 300 019-2-1
Short Circuit Proof Environmental EN 300 019-2-2
Output Fuse Protection EN 300 019-2-3
Over Temperature Shut-Off
Hot-plug Inrush Current
Limiting PART NO. DESCRIPTION
Efficiency Peak 96.0%
HE-512865 Serenity 48V/3000W SMR
Specifications are subject to change without notice Web: www.exicom-ps.com
India Sales APAC Sales Africa Sales
[email protected] [email protected] [email protected] Plot 2A, Anath Road, Sector 18, Exicom Tele-Systems (Singapore) Pte Ltd | 77 / 79, Eric Moore Road, Surulere,
Guragon 122015, India 7500A, Beach Road, #12-318-9, The Plaza, Lagos, Nigeria
Singapore 199591