Catalyst 2900 Series XL
Catalyst 2900 Series XL
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION
PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO
LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate
radio-frequency energy. If it is not installed in accordance with Cisco’s installation instructions, it may cause interference with radio and television
reception. This equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in
part 15 of the FCC rules. These specifications are designed to provide reasonable protection against such interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation.
Modifying the equipment without Cisco’s written authorization may result in the equipment no longer complying with FCC requirements for Class
A or Class B digital devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct
any interference to radio or television communications at your own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco
equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by
using one or more of the following measures:
• Move the equipment to one side or the other of the television or radio.
• Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television
or radio are on circuits controlled by different circuit breakers or fuses.)
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as
part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE
PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL
DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR
INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES.
AccessPath, AtmDirector, Browse with Me, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, CiscoLink, the Cisco NetWorks logo, the
Cisco Powered Network logo, Cisco Systems Networking Academy, the Cisco Systems Networking Academy logo, Fast Step, Follow Me Browsing,
FormShare, FrameShare, GigaStack, IGX, Internet Quotient, IP/VC, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ Logo, iQ Net Readiness
Scorecard, MGX, the Networkers logo, Packet, PIX, RateMUX, ScriptBuilder, ScriptShare, SlideCast, SMARTnet, TransPath, Unity, Voice LAN,
Wavelength Router, and WebViewer are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Discover All That’s
Possible, and Empowering the Internet Generation, are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, Cisco, the Cisco
Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo,
All other brands, names, or trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word
partner does not imply a partnership relationship between Cisco and any other company. (0102R)
Preface xi
Audience xi
Purpose xi
Organization xii
Conventions xii
Related Publications xvi
Obtaining Documentation xvii
World Wide Web xvii
Cisco Documentation CD-ROM xvii
Ordering Documentation xviii
Documentation Feedback xviii
Obtaining Technical Assistance xix
Cisco.com xix
Technical Assistance Center xix
Contacting TAC by Using the Cisco TAC Website xx
Contacting TAC by Telephone xx
INDEX
Audience
This guide is for the networking or computer technician responsible for installing
and configuring a Catalyst 2900 series XL switch. We assume that you are
familiar with the concepts and terminology of Ethernet and local area networking.
Purpose
The Catalyst 2900 Series XL Hardware Installation Guide documents the
hardware features of Catalyst 2900 series XL switches. It describes the physical
and performance characteristics of the switches, explains how to install a switch,
and provides troubleshooting information and specifications.
Organization
This guide is organized into the following chapters:
Chapter 1, “Product Overview,” summarizes the switch features, and describes
the ports, the standards they support, and the LEDs.
Chapter 2, “Installation,” provides the procedures for installing a switch in a rack,
on a desk, or on a wall.
Chapter 3, “Troubleshooting,” describes how to identify and resolve some of the
problems that might arise when you are installing the switch.
Appendix A, “Technical Specifications,” lists the physical and environmental
specifications for the switches and the regulatory agency approvals.
Appendix B, “Connectors and Cable Specifications,” describes the connectors,
cables, and adapters that can be used to connect to the switch.
Appendix C, “Translated Safety Warnings,” provides translations in various
languages of the warnings in this guide.
Conventions
This guide uses the following conventions to convey instructions and information:
Command descriptions use these conventions:
• Commands and keywords are in boldface.
• Arguments for which you supply values are in italic.
Examples use these conventions:
• Terminal sessions and system displays are in screen font.
• Information you enter is in boldface screen font.
• Nonprinting characters, such as passwords or tabs, are in angle brackets (< >).
Notes, cautions, and warnings use the following conventions and symbols:
Note Means reader take note. Notes contain helpful suggestions or references to
materials not contained in this manual.
Caution Means reader be careful. In this situation, you might do something that could
result in equipment damage or loss of data.
Warning This warning symbol means danger. You are in a situation that could cause
bodily injury. Before you work on any equipment, be aware of the hazards
involved with electrical circuitry and be familiar with standard practices
for preventing accidents. (To see translations of the warnings that appear
in this publication, refer to the Appendix C, “Translated Safety Warnings.”)
Related Publications
You can order printed copies of documents with a DOC-xxxxxx= number.
The following publications provide more information about the switches:
• Release Notes for the Catalyst 2900 Series XL and Catalyst 3500 Series XL,
Cisco IOS Release 12.0(5)WC(1)
• Catalyst 2900 XL and Catalyst 3500 XL Documentation CD
This CD is shipped with the switch and has the following publications:
– This Catalyst 2900 Series XL Hardware Installation Guide
(order number DOC-786461=)
– Catalyst 2900 Series XL and Catalyst 3500 Series XL Software
Configuration Guide, Cisco IOS Release 12.0(5)WC(1)
(order number DOC-786511=)
– Catalyst 2900 Series XL and Catalyst 3500 Series XL Command
Reference, Cisco IOS Release 12.0(5)WC(1)
(order number DOC-7812155=)
– Catalyst 2900 Series XL Modules Installation Guide
(order number DOC-CAT2900-IG=)
– Catalyst 2900 Series XL ATM Modules Installation and Configuration
Guide (order number DOC-785472=)
– 1000BASE-T Gigabit Interface Converter Installation Note
(not orderable but is available on Cisco.com)
– Catalyst GigaStack Gigabit Interface Converter Hardware Installation
Guide (order number DOC-786460=)
Obtaining Documentation
The following sections provide sources for obtaining documentation from Cisco
Systems.
Note This CD contains the documentation for all Cisco products and is shipped with
all Cisco products. This CD is not the same as the Catalyst 2900 XL and
Catalyst 3500 XL Documentation CD, which contains only the
Catalyst 2900 XL and Catalyst 3500 XL switch documents and related
hardware documents.
Ordering Documentation
Cisco documentation is available in the following ways:
• Registered Cisco Direct Customers can order Cisco Product documentation
from the Networking Products MarketPlace:
http://www.cisco.com/cgi-bin/order/order_root.pl
• Registered Cisco.com users can order the Documentation CD-ROM through
the online Subscription Store:
http://www.cisco.com/go/subscription
• Nonregistered CCO users can order documentation through a local account
representative by calling Cisco corporate headquarters (California, USA) at
408 526-7208 or, in North America, by calling 800 553-NETS(6387).
Documentation Feedback
If you are reading Cisco product documentation on the World Wide Web, you can
send us your comments by completing the online survey. When you display the
document listing for this platform, click Give Us Your Feedback. If you are using
the product-specific CD and you are connected to the Internet, click the
pencil-and-paper icon in the toolbar to display the survey. After you display the
survey, select the manual that you wish to comment on. Click Submit to send your
comments to the Cisco documentation group.
You can e-mail your comments to [email protected].
To submit your comments by mail, for your convenience many documents contain
a response card behind the front cover. Otherwise, you can mail your comments
to the following address:
Cisco Systems, Inc.
Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Cisco.com
Cisco.com is the foundation of a suite of interactive, networked services that
provides immediate, open access to Cisco information and resources at anytime,
from anywhere in the world. This highly integrated Internet application is a
powerful, easy-to-use tool for doing business with Cisco.
Cisco.com provides a broad range of features and services to help customers and
partners streamline business processes and improve productivity. Through
Cisco.com, you can find information about Cisco and our networking solutions,
services, and programs. In addition, you can resolve technical issues with online
technical support, download and test software packages, and order Cisco learning
materials and merchandise. Valuable online skill assessment, training, and
certification programs are also available.
Customers and partners can self-register on Cisco.com to obtain additional
personalized information and services. Registered users can order products, check
on the status of an order, access technical support, and view benefits specific to
their relationships with Cisco.
To access Cisco.com, go to the following website:
http://www.cisco.com
Features
The switches are stackable 10/100 Ethernet switches to which you can connect
workstations, Cisco IP Phones, and other network devices such as servers,
routers, and other switches. The 2900 XL LRE switches employ Long-Reach
Ethernet (LRE), a very-high-data-rate digital subscriber line (VDSL)-based
technology that allows an Ethernet network to reach distances up to 4921 feet
(1500 meters). The switches can be deployed as backbone switches, aggregating
10/100 and Gigabit Ethernet traffic from other network devices.
The Catalyst 2900 XL switches have these features:
• Autonegotiates speed and duplex operation on all 10/100 ports
• Operates in full-duplex mode on all 100BASE-FX ports
• Checks for errors on a received packet, determines the destination port, stores
the packet in shared memory, and then forwards the packet to the destination
port
RESET
PWR
PWR
TEMP
FAN
9X
10X
11X
12X
RESET
PWR
PWR
TEMP
FAN
9X
10X
11X
12X
Catalyst
2900
SERIE
S XL
12X
-T/100BASE-TX
13X
14X
15X
16X
17X Catalyst
18X
19X
2900
SERIE
20X
21X
100BA
SE-FX
S XL
22X
23
24
Catalyst
1 2900
SERIE
2 S XL
MODE
3
4
100BAS
E-FX
5
6
7
8
9
10
11
12
11X
12X
13X
14X
15X
16X
17X
18X
47294
19X
20X
21X
22X
23X
24X
Front-Panel Description
Depending on the model, the switch front panels can have up to 24 10/100 ports
(See Figure 1-2), up to 12 100BASE-FX ports (See Figure 1-2), 2 expansion slots
(see Figure 1-2), and up to 24 Long-Reach Ethernet ports (See Figure 1-4). All
switches have a set of LEDs and a Mode button. This section describes these
front-panel components.
1X
52646
2X
3X
4X
MODE 5X
6X
7X
8X 10BASE
-T/100BASE
100BaseFX
9X -TX
10X
11X
12X
13X
14X
15X
16X
17X Catalys
18X t 2900
19X SERIES
20X
21X
100BA
SE-FX
XL
22X
23
24
10/100 ports
100BASE-FX ports
Expansion slots
1 2
Catalys
1 t 2900
SERIES
XL
47286
2
MODE
3
4
100BAS
5 E-FX
6
7
8
9
10
11
12
100BASE-FX ports
INPUT
PWR
OUTPUT
PWR
RESET 9X
TEMP 10X
FAN 11X
12X
Catalyst
2900 LRE XL
48005
10/100 ports
LRE ports
10/100 Ports
The 10/100 switch ports (see Figure 1-2 and Figure 1-4) can connect to any
compatible network device up to 328 feet (100 meters) away:
• 10BASE-T-compatible devices, such as workstations, Cisco IP Phones, and
hubs through standard RJ-45 connectors and Category 3, 4, or 5 cabling
• 100BASE-TX-compatible devices, such as high-speed workstations,
Cisco IP Phones, servers, hubs, routers, and other switches through standard
RJ-45 connectors and Category 5 cabling
The 10/100 switch ports can be explicitly set to operate in any combination of
half duplex, full duplex, 10 Mbps, or 100 Mbps. These ports also can be set for
speed and duplex autonegotiation, compliant with IEEE 802.3u. When set for
autonegotiation, the port senses the speed and duplex settings of the attached
device and advertises its own capabilities. If the connected device also supports
autonegotiation, the switch port negotiates the best connection (that is, the fastest
line speed that both devices support and full-duplex transmission if the attached
device supports it) and configures itself accordingly.
The 10/100 ports on the Catalyst 2900 XL switches provide protocol support for
Cisco IP Phones and per-port priority override. Refer to the Catalyst 2900 Series
XL and Catalyst 3500 Series XL Software Configuration Guide for more
information about these features.
Cisco IP Phones—connected to the 10/100 port—must be connected to an AC
power source. Unlike the 3524-PWR XL switch, the Catalyst 2900 XL switches
do not provide inline power.
For more info on the Catalyst 3524-PWR XL switch, refer to the
Catalyst 3500 Series XL Hardware Installation Guide.
100BASE-FX Ports
The 100BASE-FX ports use 10/125- or 62.5/125-micron multimode fiber-optic
cabling. The connection distances between the switch and the attached device can
be as follows:
• If the switch port and the port on the attached device are configured for
half-duplex operation, the connection can be up to 1352 feet (412 meters).
• If the switch port and the port on the attached device are configured for
full-duplex operation, the connection can be over distances of up to 6562 feet
(2 kilometers).
Expansion Slots
The expansion slots (see Figure 1-2) are for the Catalyst 2900 XL hot-swappable
modules. Each module port is internally switched to other switch ports and is
managed through the switch management interfaces.
Table 1-1 lists the modules that the expansion slots support.
LEDs
You can use the switch LEDs to monitor switch activity and its performance.
Figure 1-5, Figure 1-6, and Figure 1-7 show the location of the LEDs and the
Mode button that you use to select a port mode. Changing a port mode changes
the information provided by each port LED.
All of the LEDs described in this section except the utilization meter (UTL) are
visible on the Cluster Management Suite (CMS) window and, if the switch is a
cluster member, on the CMS Cluster Manager window. The Catalyst 2900 Series
XL and Catalyst 3500 Series XL Software Configuration Guide describes how to
use CMS to manage standalone or individual switches and how to use cluster
management software to manage switch clusters].
Figure 1-5 Catalyst 2912 XL, 2924 XL, and 2924C XL LEDs
System LED
Port mode LEDs 1X
2X
3X
4X
MODE 5X
6X
7X
47288
Mode RPS
button LED
1 2
1
2
MODE
3
4
100BASE
-FX
5
6
7
System LED
48003
RPS LED
Expansion slot status LED
Port mode LED
Mode button
SYSTEM
RPS
MODE 1X
LRE 2X
STAT 3X
DUPLX 4X
SPEED
Mode
button
System LED
RPS LED
48002
LRE LED
STAT LED LRE port LEDs 1-12
DUPLEX LED LRE port LEDs 13-24
Speed LED
System LED
The system LED shows whether the system is receiving power and functioning
properly. Table 1-2 lists the LED colors and their meanings.
For information on the System LED colors during POST, see the “Powering On
the Switch and Running POST” section on page 2-25.
RPS LED
The Catalyst 2912 LRE XL, Catalyst 2924 LRE XL, and Catalyst 3524-PWR XL
switches use the Cisco RPS 300 (model PWR300-AC-RPS-N1). All other
Catalyst 2900 XL and Catalyst 3500 XL switches use the Cisco RPS 600
(model PWR600-AC-RPS). Refer to the appropriate switch documentation for
redundant power system (RPS) descriptions specific for the switch. Table 1-3 and
Table 1-4 list the RPS LED colors and their meanings.
Table 1-3 RPS LED on the Catalyst 2912 XL, 2924C XL, 2924 XL, 2924MF XL, and 2924M XL
Switches
Table 1-4 RPS LED on the Catalyst 2912 LRE XL and 2924 LRE XL Switches
Table 1-4 RPS LED on the Catalyst 2912 LRE XL and 2924 LRE XL Switches (continued)
Table 1-5 Port Mode LEDs on the Catalyst 2912 XL, 2924C XL, 2924 XL, 2924MF XL, and 2924M XL
Switches
Table 1-6 Meanings of Port Status LED Colors for Different Modes on Catalyst 2912 LRE XL and
2924 LRE XL Switches
Table 1-7 Meanings of Port Status LED Colors for Different Modes on Catalyst 2912 XL, 2924C XL,
2924 XL, 2924MF XL, and 2924M XL Switches
Table 1-8 Meanings of Port Status LED Colors for Different Modes on Catalyst 2912 LRE XL and
2924 LRE XL Switches
47293
MODE
6.25 –12.4%+
12.5 –24%+
25 – 49%+
50%+
Rear-Panel Description
The switch rear panels have an AC power connector, an RPS connector, and an
RJ-45 console port (see Figure 1-10, Figure 1-10, and Figure 1-11), which are
described in this section.
Figure 1-9 Catalyst 2912 XL, 2924 XL, and 2924C XL Rear Panel
Fans
DC INP
UTS FOR
RATING POWER REMOTE
100-127 SPECIF SUPPLY
/200-240 IED IN
1.0A/O.5 V~ +5V MANUA
A 50-8 @9A, +12 L
0HZ V @0.5A
CONSO
LE
47295
AC power
connector Redundant
power system RJ-45
connector connector
Fans
CONSOL
E
DC INP
UTS FO
POWE R REMO
TE
SPECIFIE R SUPPLY
+5V D IN RATING
@9A, +12 MANUAL 100-12
0/2
V @0.5A 2.0A/1.0A 00-240V ~
50-60H
47296
Z
DC INP
UT
RJ-45
connector
Redundant
power system AC power
connector connector
Figure 1-11 Catalyst 2912 LRE XL and 2924 LRE XL Rear Panel
100-24
0V~
5-3A MAXIM
UM 300
50/60H W TOTAL
z OUTP
UT
48004
DC OU
TP UT
AC power
CONSO
LE
connector Redundant
power system
connector
RJ-45
connector
Power Connectors
You can provide power to the switch either through the internal power supply or
through the Cisco RPS.
RPS Connector on the Catalyst 2912 XL, 2924C XL, 2924 XL, 2924MF XL, and 2924M XL Switches
Warning Attach only the Cisco RPS (model PWR600-AC-RPS) to the RPS 600
receptacle.
Note Do not connect the switch power cord to an AC outlet if the switch is also
connected to a powered-on RPS. The switches do not support the
fully-redundant configuration described in the RPS documentation. The
redundant-with-reboot configuration is not recommended.
For more information on the Cisco RPS 600, refer to the Cisco Redundant Power
System Hardware Installation Guide.
RPS Connector on the Catalyst 2912 LRE and 2924 LRE XL Switches
The RPS is a 300W redundant power system that can support six external network
devices and provides power to one failed device at a time. It automatically senses
when the power supply of a connected device fails and provides the necessary
power to the failed device to prevent loss of network traffic. When the device
internal power supply has been brought up or replaced, the RPS automatically
stops powering the device.
Warning Attach only the Cisco RPS (model PWR300-AC-RPS-N1) to the RPS 300
receptacle.
Note The RPS can only power one switch at a time. If more than one switch fails at
the same time, any subsequent switch is not supported by the RPS until the
first switch failure is resolved.
For more information on the Cisco RPS 300, refer to the Cisco Redundant Power
System 300 Hardware Installation Guide.
Console Port
You can connect a switch to a PC through the switch console port and by using
the supplied rollover cable and DB-9 adapter. You need to provide a
RJ-45-to-DB-25 female DTE adapter to connect the switch console port to a
terminal. You can order a kit (part number ACS-DSBUASYN=) containing that
adapter from Cisco. For console port and adapter pinout information, see the
“Connecting to the Console Port” section on page 2-33.
This chapter describes how to install your Catalyst 2900 XL switch and interpret
the power-on self-test (POST) that ensures proper operation. Read the topics and
perform these procedures in the order that they are presented:
• Pre-installation information and guidelines
• Installation procedures
• Power-on procedures
• Connection procedures
• Where to go next
Note See the Catalyst 2900 Series XL Modules Installation Guide and the
Catalyst 2900 Series XL ATM Modules Installation and Configuration Guide
for global information about the Catalyst 2900 series XL expansion modules.
Warnings
These warnings are translated into several languages in Appendix C, “Translated
Safety Warnings.”
Warning Only trained and qualified personnel should be allowed to install or replace
this equipment.
Warning Read the installation instructions before you connect the system to its
power source.
Warning Do not stack the chassis on any other equipment. If the chassis falls, it can
cause severe bodily injury and equipment damage.
Warning To prevent the switch from overheating, do not operate it in an area that
exceeds the maximum recommended ambient temperature of 113×F (45×C).
To prevent airflow restriction, allow at least 3 inches (7.6 cm) of clearance
around the ventilation openings.
Warning When installing the unit, the ground connection must always be made first
and disconnected last.
Warning Care must be given to connecting units to the supply circuit so that wiring is
not overloaded.
Warning A voltage mismatch can cause equipment damage and may pose a fire
hazard. If the voltage indicated on the label is different from the power
outlet voltage, do not connect the chassis to that receptacle.
Warning Do not touch the power supply when the power cord is connected. For
systems with a power switch, line voltages are present within the power
supply even when the power switch is off and the power cord is connected.
For systems without a power switch, line voltages are present within the
power supply when the power cord is connected.
Warning Do not work on the system or connect or disconnect cables during periods
of lightning activity.
Warning Ultimate disposal of this product should be handled according to all national
laws and regulations.
Warning Invisible laser radiation may be emitted from the aperture ports of the
100BASE-FX single-mode supervisor engine module. Avoid exposure and do
not stare into open apertures.
Warning Attach only the Cisco RPS (model PWR600-AC-RPS) to the RPS receptacle.
Warning Attach only the Cisco RPS (model PWR300-AC-RPS-N1) to the RPS
receptacle.
U.S.A.
U.S. regulatory information for this product is in the front matter of this manual.
Taiwan
15456
Hungary
This equipment is a class A product and should be used and installed properly
according to the Hungarian EMC Class A requirements (MSZEN55022). Class A
equipment is designed for typical commercial establishments for which special con-
ditions of installation and protection distance are used.
Installation Guidelines
The switch can be installed on a table or shelf, in a rack, or on a wall.
Before installing the switch, first verify that the switch is operational by powering
it on and running POST. Follow the procedures in the “Powering On the Switch
and Running POST” section on page 2-25.
Caution There are no serviceable parts inside the unit. Removing screws, cover, or
otherwise dismantling the unit voids the warranty.
Warning Unplug the power cord before you work on a system that does not have an
on/off switch.
When determining where to place the switch, be sure to observe these guidelines:
• For 10/100 ports, cable lengths from the switch to connected devices are up
to 328 feet (100 meters).
• For 100BASE-FX ports, cable lengths from the switch to connected devices
are up to 1351 feet (412 meters) for half-duplex connections and less than
6561 feet (2 kilometers) for full-duplex connections.
• For LRE ports, cable lengths from the switch to the connected Ethernet
device are up to 4921 feet (1500 meters).
• Cabling is away from sources of electrical noise, such as radios, power lines,
and fluorescent lighting fixtures.
• For specifications of the expansion modules, refer to the modules
documentation in the “Related Publications” section on page xvi.
• Clearance to front and rear panels meet these conditions:
– Front-panel indicators can be easily read.
– Access to ports is sufficient for unrestricted cabling.
– Rear-panel power connector is within reach of an AC power receptacle.
• Operating environment is within the ranges listed in Appendix A, “Technical
Specifications.”
• Airflow around the switch and through the vents is unrestricted.
• Temperature around the unit does not exceed 113°F (45°C).
Note The cable guide is not applicable for the Catalyst 2912 LRE XL
and 2924 LRE XL switches.
Step 1 Locate the adhesive strip with the rubber feet in the mounting-kit envelope.
Attach the four rubber feet to the recessed areas on the bottom of the unit.
Step 2 Place the switch on the table or shelf near an AC power source.
Step 3 After the switch is mounted on the table or shelf, power the switch as described
in “Powering On the Switch and Running POST” section on page 2-25.
• This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
• When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
The supplied rack-mounting brackets can be attached to a 19-, 23-, or 24-inch
rack. Figure 2-1 shows which mounting holes to use.
Note Figure 2-1 shows brackets for two-rack-unit modular switches. Rack-mount
points are similar on brackets for one-rack-unit switches.
Figure 2-1 Mounting Bracket Points for Catalyst 2912 XL, 2924C XL, 2924 XL,
2912MF XL, or 2924M XL Switches
47307
19" rack 24" rack 23" rack
mount point mount point mount point
Figure 2-2 Mounting Brackets Points for Catalyst 2912 LRE XL and
2924 LRE XL Switches
54725
To install the switch in a 19-, 23- or 24-inch standard rack, follow the instructions
described in these procedures:
• “Removing Screws from the Switch” section on page 2-10
• “Attaching the Brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF
XL, or 2924M XL Switch” section on page 2-11
• “Attaching the Brackets to a Catalyst 2912 LRE XL or 2924 LRE XL Switch”
section on page 2-17
• “Mounting the Switch in a Rack” section on page 2-19
• “Attaching the Optional Cable Guide” section on page 2-20
Fixed-port
Catalys
t 2900
SERIE
S XL Catalyst 2900 series XL
Catalys
t 2900
SERIE
S XL Modular
Catalyst 2900 series XL
22X
23X
24X
47292
Attaching the Brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL,
2912MF XL, or 2924M XL Switch
Follow these steps to attach the brackets to a Catalyst 2912 XL, 2924C XL, 2924
XL, 2912MF XL, or 2924M XL switch:
The bracket orientation and screws that you use depend on whether you are
attaching the brackets for a 19-, 23-, or 24-inch rack. Use two of the supplied
screws to attach each bracket, according to rack size:
• For a 19-inch rack, use the supplied Phillips flat-head screws to attach the
long side of the bracket to the switch.
• For a 23- or 24-inch rack, use the supplied Phillips truss-head screws to attach
the short side of the bracket to the switch.
Figure 2-3, Figure 2-5, Figure 2-6, Figure 2-7, and Figure 2-8 show how to attach
a bracket to one side of the switch. Follow the same steps to attach the second
bracket to the opposite side of the switch.
Figure 2-4 Attaching Brackets on Catalyst 2912 XL, 2924C XL, 2924 XL Fixed-Port Switches
(Front-Panel Forward)
Phillips
flat-head
screws
1X
2X
3X
4X
19" configuration MODE 5X
6X
7X
Phillips
truss-head
screws
1X
47738
2X
3X
4X
23" and 24" configuration M ODE 5X
6X
7X
Phillips
flat-head
screws
1 2
1X
2X
19" configuration
3X
4X
MODE 5X
6X
7X
Phillips
truss-head
screws
1 2
1X
2X
3X
47297
7X
Figure 2-6 Attaching Brackets on Catalyst 2912 XL, 2924C XL, 2924 XL
Fixed-Port Switches (Rear-Panel Forward)
Phillips
flat-head
screws
19" configuration
Phillips
truss-head
screws
47298
23" and 24" configuration
Phillips
flat-head
screws
RATING
100-12
0/2
2.0A/1.0A 00-240V ~
50-60H
Z
DC INP
UT
19" configuration
Phillips
truss-head
RATING
100-12
0/2
2.0A/1.0A 00-240V ~
50-60H
Z
screws
DC INP
UT
47299
23" and 24" configuration
Phillips
flat-head
screws
RATING
100-12
0/2
2.0A/1.0A 00-240V ~
50-60H
Z
DC INP
UT
Phillips
52532
flat-head
screws
Note Catalyst 2912 LRE XL and 2924 LRE XL switches cannot be mounted in telco
racks.
Figure 2-9 Attaching Brackets on Catalyst 2912 LRE XL and 2924 LRE XL Switches (Front-Panel
Forward)
Phillips
flat-head
screws
INPUT
PWR
OUTPUT
PWR
RESET 9X
TEMP 10X
FAN 11X
12X
19" configuration
Phillips
truss-head
screws
INPUT
PWR
OUTPUT
PWR
RESET 9X
TEMP 10X
FAN 11X
12X
54728
Figure 2-10 Attaching Brackets on Catalyst 2912 LRE XL and 2924 LRE XL Switches (Rear-Panel
Forward
Phillips
flat-head
screws
19" configuration
Phillips
truss-head
screws
54824
23" and 24" configuration
1X
2X
3X
4X
MODE 5X
6X
7X
8X 10BaseT 100BaseF
9X /100Bas
eTX X
10X
11X
12X
13X
14X
16X
17X Catalys
18X t 2900
19X SERIES
20X
21X
XL
22X
23X
24X
Phillips machine
screws
1 2
Catalys
1X t 2900
2X SERIES
3X XL
4X
MODE 5X
6X
7X
8X 100BaseF
9X X
10X
11X
12X
13X
14X
15X
16X
17X
47301
18X
19X
20X
21X
22X
23X
24X
Phillips machine
screws
After the switch is mounted in the rack, power the switch as described in
“Powering On the Switch and Running POST” section on page 2-25.
Note The cable guide is not applicable for the Catalyst 2912 LRE XL and
2924 LRE XL switches.
1X
2X
3X
4X
MODE 5X
6X
7X
8X 10BaseT 100BaseF
9X /100Bas
eTX X
10X
11X
12X
13X
14X
16X
17X Catalys
18X t 2900
19X SERIES
20X
21X
XL
22X
23X
24X
1 2
Catalys
1X t 2900
2X SERIES
3X XL
4X
MODE 5X
6X
7X
8X 100BaseF
9X X
10X
11X
12X
13X
14X
15X
16X
17X
47302
18X
19X
20X
21X
22X
23X
24X
Note The Catalyst 2912 LRE XL and 2924 LRE XL switches cannot be mounted
vertically on a wall.
Figure 2-13 and Figure 2-13 show how to attach the brackets to one side of the
switch. Follow the same steps to attach the second bracket to the opposite side of
the switch.
Figure 2-13 Attaching Brackets for Parallel and Vertical Wall-Mounting for
Fixed-Port Switches
Phillips
truss-head
47303
screws
Figure 2-14 Attaching Brackets for Parallel and Vertical Wall-Mounting for
Modular Switches
RATING
100-12
0/2
2.0A/1.0A 00-240V ~
50-60H
Z
DC INP
UT
Phillips
truss-head 47304
screws
Vertical
wall stud
SERIES
User-supplied
24x
23x
screws
22x
21x
20x
19x
18x
17x
16x
15x
14x
10BaseT/100BaseTx
13x
12x
11x
10x
9x
8x
7x
6x
5x
4x
3x
2x
1x
RPS
47305
MODE
Vertical
wall stud
User-supplied
screws
SERIES
SERIES
24x
23x
22x
21x
24x
20x
23x
19x
22x
18x
21x
17x
20x
16x
User-supplied
19x
15x
14x
18x
10BaseT/100BaseTX
screws
13x
17x
12x
16x
11x
15x
10x
14x
9x
10BaseT/100BaseTX
13x
8x
12x
7x
11x
6x
10x
5x
4x
9x
3x
8x
2x
7x
1x
6x
MODE
5x
4x
3x
2x
1x
MODE
47306
Vertical wall-mount Parallel wall-mount
After the switch is mounted on the wall, power the switch as described in
“Powering On the Switch and Running POST” section on page 2-25.
Step 1 Connect one end of the AC power cord to the AC power connector on the switch.
Step 2 Connect the other end of the power cord to an AC power outlet.
As the switch powers on, it begins POST, a series of eight tests that run
automatically to ensure that the switch functions properly. When the switch
begins POST, the port LEDs turn amber for 2 seconds, and then they turn green.
The System LED flashes green, and the RPS LED turns off. As each test runs, the
port LEDs, starting with number 1, turn off. The port LEDs for ports 2 to 8 each
turn off in turn as the system completes a test.
When POST completes successfully, the port LEDs return to the status mode
display, indicating that the switch is operational. If a test fails, the port LED
associated with the test turns amber, and the system LED turns amber. If POST
fails, refer to Chapter 3, “Troubleshooting,” to determine a course of action.
POST failures are usually fatal. Call Cisco Systems immediately if your switch
does not pass POST.
Step 1 When connecting to workstations, servers, routers, and Cisco IP Phones, connect
a straight-through Category 5 cable to an RJ-45 connector on the front panel
(Figure 2-17). When connecting to switches or repeaters, use a crossover
Category 5 cable. Pinouts for the cables are described in the “Cable and Adapter
Specifications” section on page B-4.
1X
2X
3X
4X
MODE 5X
6X
7X
47291
Note The switch can connect to a Cisco IP Phone through a straight-through,
twisted-pair cable. The rear panel of the Cisco IP Phone might have more than
one RJ-45 jack. Use the LAN-to-phone jack to connect the phone to the
switch. Refer to the documentation that came with your Cisco IP Phone for
information about connecting devices to it.
Step 2 Connect one end of the cable to the RJ-45 connector of the switch 10/100 port.
Step 3 Connect the other end of the cable to an RJ-45 connector of the other device.
The switch port LED comes on when both the switch and the connected device
have established link.
The port LED is amber while Spanning Tree Protocol (STP) discovers the
topology and searches for loops. This takes about 30 seconds, and then the port
LED turns green.
If the port LED does not come on, the device at the other end might not be turned
on, or there might be a cable problem or a problem with the adapter installed in
the attached device. See Chapter 3, “Troubleshooting,” for solutions to cabling
problems.
Step 4 Reconfigure and reboot the connected device if necessary.
Step 5 Repeat Steps 1 through 3 to connect to each 10/100 port.
Caution Do not remove the rubber plugs from the fiber-optic port or the rubber caps
from the fiber-optic cable until you are ready to connect the cable. The plugs
and caps protect the fiber-optic port and cable from contamination and
ambient light.
• If the switch port and the port on the attached device are configured for
half-duplex operation, the connection can be up to 412 meters.
• If the switch port and the port on the attached device are configured for
full-duplex operation, the connection can be up to 2 kilometers.
Step 1 Remove the rubber plugs from the port and the rubber caps from the cable
connectors.
Step 2 Connect one end of the fiber-optic cable to the 100BASE-FX port on the switch,
as shown in Figure 2-18.
47287
Catalys
t 2900
SERIE
100BAS S XL
E-FX
23
24
100BASE-FX port
Fiber-optic
cable
Step 3 Connect the other end of the cable to the 100BASE-FX port of the other device.
Step 4 The port LED comes on when both the switch and the connected device have
established link.
The port LED is amber while the STP discovers the topology and searches for
loops. This takes about 30 seconds, and then the port LED turns green.
If the port does not come on, the device at the other end might not be turned on,
or there might be a cable problem or a problem with the adapter installed in the
attached device. See Chapter 3, “Troubleshooting,” for solutions to cabling
problems.
Note If no other telephone services travel on the same wiring as LRE traffic, the
LRE switch connects directly to a patch panel.
Step 1 Connect one end of a wiring trunk cable to the RJ-21 connector of the LRE port
on the switch. (See Figure 2-19.)
RJ-21 connector
SYSTEM
RPS
MODE 1X
LRE 2X
STAT 3X
DUPLX 4X
SPEED
Screw
RJ-21
Screw
connector
Cable to
wiring trunk
RJ-21 connector
SYSTEM
RPS
MODE 1X
LRE 2X
STAT 3X
DUPLX 4X
SPEED
54560
Screw
RJ-21 0.20 inch
connector (5 mm)
Cable to Cable tie
wiring trunk
Step 2 Referring to the following figure, secure the cable to the switch:
• For a 90-degree connector, see the top of Figure 2-19.
• For a 12-degree connector, see the bottom Figure 2-19.
Note The cable tie is not included with the connector and cable assembly.
Step 3 Connect the other end of the cable to the patch panel or POTS splitter.
Each LRE port status LED turns on when it establishes a link with a Cisco
575 LRE CPE. For more information about the LRE link between the switch LRE
port and the CPE, as well as information about the configuration and management
of CPE devices, refer to the Catalyst 2900 Series XL and Catalyst 3500 Series XL
Software Configuration Guide.
For more information about the Cisco 575 LRE CPE device, refer to the
Cisco 575 LRE CPE Hardware Installation Guide.
If telephone services, such as voice or ISDN, use the same cabling as LRE traffic,
the LRE port must be connected to the patch panel through a basic telephone
service, also known as plain old telephone service (POTS) splitter. The splitter
routes LRE data (high-frequency) and voice (low-frequency) traffic from the
telephone line to the switch and private branch exchange (PBX) switch or
public-switched telephone network (PSTN).
If the other telephone services are connected through a PBX switch, a
Cisco LRE 48 POTS Splitter can be used. The PBX routes voice traffic to private
telephone networks and the public system telephone network (PSTN). For more
information about the Cisco LRE 48 POTS Splitter (PS-1M-LRE-48), refer to the
Installation Notes for the Cisco LRE 48 POTS Splitter.
If the installation does not have a PBX, a homologated POTS splitter is required
to directly connect to the PSTN. For more information about homologated POTS
splitters, contact your Cisco sales representative.
Step 3 Using the supplied rollover cable, connect one end of the rollover cable into the
console port, as shown in Figure 2-20. See the “Identifying a Rollover Cable”
section on page B-6 for a description of the pinout.
DC INP
UTS FO
CONS POW R REM
O
OLE
SPECIF ER SUPPLY TE
+5V IED IN
@24A, MANU
+12V AL.
@1.0A
47308
Console port
Rollover cable
Where to Go Next
After the switch passes POST, it can operate on its default settings and passwords
after you configure IP information on the switch. For information about using the
setup program, refer to the Release Notes for the Catalyst 2900 Series XL and
Catalyst 3500 Series XL Cisco IOS Release 12.0(5)WC(1).
For information about configuring the switch, refer to the Catalyst 2900 Series XL
and Catalyst 3500 Series XL Software Configuration Guide.
The LEDs on the front panel of the Catalyst 2900 series XL switch provide
troubleshooting information about the switch. They show failures in the power-on
self-test (POST), port-connectivity problems, and overall switch performance.
For a full description of the switch LEDs, see the “LEDs” section on page 1-9.
You can also get statistics from the browser interface, from the command-line
interface (CLI), or from an SNMP workstation. See the Catalyst 2900 Series XL
and Catalyst 3500 Series XL Software Configuration Guide, the Catalyst 2900
Series XL and Catalyst 3500 Series XL Command Reference, or the
documentation that came with your SNMP application for details.
This chapter describes the following topics for troubleshooting problems:
• Understanding POST Results
• Diagnosing Problems
Note POST failures are usually fatal. Call Cisco Systems if your switch does not
pass POST.
Diagnosing Problems
Common switch problems fall into the following categories:
• Poor performance
• No connectivity
• Corrupted software
Table 3-2 describes how to detect and resolve these problems.
Table A-1, Table A-2, Table A-3, and Table A-4 list the technical specifications
for the Catalyst 2900 series switches.
For switches that support modules (Catalyst 2912MF XL and 2924M XL), also
refer to the Catalyst 2900 Series XL Modules Installation Guide and the Catalyst
2900 Series XL ATM Modules Installation Guide for additional specifications.
Table A-5 lists the agency approvals for EMI and safety.
Table A-1 Technical Specifications for the Catalyst 2912 XL and Catalyst 2912MF XL Switches
Table A-2 Technical Specifications for the Catalyst 2924 XL and Catalyst 2924C XL Switches
Table A-4 Technical Specifications for the Catalyst 2912 LRE XL and
2924 LRE XL Switches
Safety EMI
UL 1950/CSA 22.2 No. FCC Part 15 Class A
950
IEC 950/EN 60950 EN 55022 Class A (CISPR 22 Class A)
AS/NZS 3260, TS001 VCCI Class A
CE AS/NZS 3548 Class A
BCIQ
CE
This appendix describes the Catalyst 2900 XL switch ports and the cables and
adapters that you use to connect the switch to other devices.
Connector Specifications
10/100 Ports
The 10/100 Ethernet ports use standard RJ-45 connectors and Ethernet pinouts
with internal crossovers, as shown by an X in the port name. These ports have
their transmit (TD) and receive (RD) signals internally crossed so that a
straight-through cable and an adapter can be attached to the port. Figure B-1
shows the pinouts.
Pin Label 1 2 3 4 5 6 7 8
1 RD+
2 RD-
3 TD+
4 NC
5 NC
6 TD-
7 NC
54968
8 NC
Note Use a straight-through cable to connect two ports when one of the ports is
designated with an X. Use a crossover cable to connect two ports when both
connectors and cables are designated with an X or when both ports do not have
an X.
100BASE-FX Ports
100BASE-FX ports use duplex SC connectors, as shown in Figure B-2. These
ports use 10/125- or 62.5/125-micron multimode fiber-optic cabling.
47739
Tx Rx
LRE Ports
The LRE ports use a single RJ-21 connector, as shown in Figure B-3.
SYSTEM
RPS
MODE 1X
LRE 2X
STAT 3X
DUPLX 4X
SPEED
48727
RJ-21
connector
Console Port
The console port uses an 8-pin RJ-45 connector, described in Table B-2 and
Table B-3. The supplied RJ-45-to-RJ-45 rollover cable and DB-9 adapter are used
to connect the console port of the switch to a console PC. You need to provide a
RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console
Switch Switch
3 TD+ 3 RD+
6 TD– 6 RD–
1 RD+ 1 TD+
H5578
2 RD– 2 TD–
Switch Switch
3 TD+ 3 TD+
6 TD– 6 TD–
1 RD+ 1 RD+
H5579
2 RD– 2 RD–
Note Table B-1 shows the pinouts for the RJ-21 connector on a
Catalyst 2924 LRE XL switch. On a Catalyst 2912 LRE XL switch, only
circuits 1 to 12 are valid.
Console Port
The console port uses an 8-pin RJ-45 connector, as shown in Figure B-7 and
described in Table B-2. The supplied RJ-45-to-RJ-45 rollover cable and adapters
connect the console port of the switch to a console PC or terminal. The following
sections describe the rollover cable and adapters for the console port.
Pin 1 Pin 8
Connecting to a PC 47740
Use the thin, flat, RJ-45-to-RJ-45 rollover cable and RJ-45-to-DB-9 female DTE
adapter (both provided) to connect the console port to a PC running
terminal-emulation software. Figure B-7 shows how to connect the console port
to a PC. Table B-2 lists the pinouts for the console port, the RJ-45-to-RJ-45
rollover cable, and the RJ-45-to-DB-9 female DTE adapter.
PC
Catalyst 2900 series XL RJ-45-to-RJ-45
rollover cable
H10972
RJ-45-to-DB-9 adapter
(labeled TERMINAL)
Table B-2 Console Port Signaling and Cabling Using a DB-9 Adapter
Connecting to a Terminal
Use the thin, flat, RJ-45-to-RJ-45 rollover cable and RJ-45-to-DB-25 female DTE
adapter to connect the console port to a terminal. Table B-3 lists the pinouts for
the console port, the RJ-45-to-RJ-45 rollover cable, and the RJ-45-to-DB-25
female DTE adapter.
Note The RJ-45-to-DB-25 female DTE adapter is not supplied with the switch. You
can order a kit (part number ACS-DSBUASYN=) containing this adapter from
Cisco.
Table B-3 Console Port Signaling and Cabling Using a DB-25 Adapter
This appendix repeats in multiple languages the warnings in this guide. These
translated warnings can be used with other documents related to this guide.
Warning Attach only the Cisco RPS (model PWR600-AC-RPS) to the RPS receptacle.
Warning Attach only the Cisco RPS (model PWR300-AC-RPS-N1) to the RPS
receptacle.
Advarsel Kun kvalifisert personell med riktig opplæring bør montere eller
bytte ut dette utstyret.
Installation Warning
Warning Read the installation instructions before you connect the system to its
power source.
Warnung Vor der Arbeit an Geräten, die an das Netz angeschlossen sind,
jeglichen Schmuck (einschließlich Ringe, Ketten und Uhren)
abnehmen. Metallgegenstände erhitzen sich, wenn sie an das
Netz und die Erde angeschlossen werden, und können schwere
Verbrennungen verursachen oder an die Anschlußklemmen
angeschweißt werden.
Warning Do not stack the chassis on any other equipment. If the chassis falls, it can
cause severe bodily injury and equipment damage.
Achtung Das Gehäuse nicht auf andere Geräte stellen. Wenn das Gehäuse
herunterfällt, besteht Gefahr schwerer Personenverletzungen
und Geräteschäden.
Advarsel Stable ikke kabinettet oppå annet utstyr. Hvis kabinettet faller,
kan det forårsake alvorlig skade på mennesker og utstyr.
¡Atención! No apilar los chasis sobre ningún otro equipo. Si el chasis se cae
al suelo puede causar graves lesiones físicas y daños al equipo.
Overtemperature Warning
Warning To prevent the switch from overheating, do not operate it in an area that
exceeds the maximum recommended ambient temperature of 104°F (40°C).
To prevent airflow restriction, allow at least 3 inches (7.6 cm) of clearance
around the ventilation openings.
TN Power Warning
Aviso O dispositivo foi criado para operar com sistemas de corrente TN.
Warning When installing the unit, the ground connection must always be made first
and disconnected last.
Warnung Der Erdanschluß muß bei der Installation der Einheit immer
zuerst hergestellt und zuletzt abgetrennt werden.
Waarschuwing Dit produkt is afhankelijk van de installatie van het gebouw voor
kortsluit- (overstroom)beveiliging. Controleer of er een zekering
of stroomverbreker van niet meer dan 120 Volt wisselstroom, 15 A
voor de V.S. (240 Volt wisselstroom, 16 A internationaal) gebruikt
wordt op de fasegeleiders (alle geleiders die stroom voeren).
Attention Cet équipement doit être relié à la terre. S’assurer que l’appareil
hôte est relié à la terre lors de l’utilisation normale.
Warnung Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das
Host-Gerät während des normalen Betriebs an Erde gelegt ist.
Warning Care must be given to connecting units to the supply circuit so that wiring
is not overloaded.
Voltage Warning
Warning A voltage mismatch can cause equipment damage and may pose a fire
hazard. If the voltage indicated on the label is different from the power
outlet voltage, do not connect the chassis to that receptacle.
Warning Do not touch the power supply when the power cord is connected. For
systems with a power switch, line voltages are present within the power
supply even when the power switch is off and the power cord is connected.
For systems without a power switch, line voltages are present within the
power supply when the power cord is connected.
Warning Do not work on the system or connect or disconnect cables during periods
of lightning activity.
Waarschuwing Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het
systeem te werken of kabels aan te sluiten of te ontkoppelen.
Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an
bzw. trennen Sie keine ab, wenn es gewittert.
Advarsel Utfør aldri arbeid på systemet, eller koble kabler til eller fra
systemet når det tordner eller lyner.
Varning! Vid åska skall du aldrig utföra arbete på systemet eller ansluta
eller koppla loss kablar.
Advarsel Endelig kassering av dette produktet skal være i henhold til alle
relevante nasjonale lover og bestemmelser.
Warning Invisible laser radiation may be emitted from the aperture ports of the
100BASE-FX single-mode supervisor engine module. Avoid exposure and
do not stare into open apertures.
Avertissement : des radiations laser invisibles peuvent être émises par les
ouvertures des ports du moteur de surveillance 100BASE-FX
monomode. Ne regardez jamais à travers ces ouvertures et ne
restez jamais devant.
Warning Unplug the power cord before you work on a system that does not have an
on/off switch.
Waarschuwing Voordat u aan een systeem werkt dat geen aan/uit schakelaar
heeft, dient u de stekker van het netsnoer uit het stopcontact te
halen.
Advarsel Før det skal utføres arbeid på et system som ikke har en
av/på-bryter, skal strømledningen trekkes ut.
• This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
• When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Waarschuwing Om lichamelijk letsel te voorkomen wanneer u dit toestel in een
rek monteert of het daar een servicebeurt geeft, moet u speciale
voorzorgsmaatregelen nemen om ervoor te zorgen dat het toestel
stabiel blijft. De onderstaande richtlijnen worden verstrekt om
uw veiligheid te verzekeren:
• Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het
enige in het rek is.
• Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert, dient u het rek
van onderen naar boven te laden met het zwaarste onderdeel onderaan in het
rek.
• Als het rek voorzien is van stabiliseringshulpmiddelen, dient u de
stabilisatoren te monteren voordat u het toestel in het rek monteert of het
daar een servicebeurt geeft.
• Si cette unité constitue la seule unité montée en casier, elle doit être placée
dans le bas.
• Si cette unité est montée dans un casier partiellement rempli, charger le
casier de bas en haut en plaçant l'élément le plus lourd dans le bas.
• Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs
avant de monter ou de réparer l'unité en casier.
• Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell
angebracht werden.
• Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das
Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im
Gestell anzubringen ist.
• Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die
Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen
oder sie warten.
• Questa unità deve venire montata sul fondo del supporto, se si tratta
dell’unica unità da montare nel supporto.
• Quando questa unità viene montata in un supporto parzialmente pieno,
caricare il supporto dal basso all’alto, con il componente più pesante
sistemato sul fondo del supporto.
• Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi
prima di montare o di procedere alla manutenzione dell’unità nel supporto.
• Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste
enheten i kabinettet.
• Ved montering av denne enheten i et kabinett som er delvis fylt, skal
kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i
kabinettet.
• Hvis kabinettet er utstyrt med stabiliseringsutstyr, skal stabilisatorene
installeres før montering eller utføring av reparasjonsarbeid på enheten i
kabinettet.
• Esta unidade deverá ser montada na parte inferior da estante, caso seja esta
a única unidade a ser montada.
• Ao montar esta unidade numa estante parcialmente ocupada, coloque os
itens mais pesados na parte inferior da estante, arrumando-os de baixo para
cima.
• Se a estante possuir um dispositivo de estabilização, instale-o antes de
montar ou reparar a unidade.
• Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad
en el mismo.
• Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado,
comenzar la instalación desde la parte inferior hacia la superior colocando el
equipo más pesado en la parte inferior.
• Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de
montar o proceder al mantenimiento del equipo instalado en el bastidor.
Numerics B
F I
long-reach Ethernet
J
See LRE
jewelry removal warning C-6 LRE
defined 1-1
LED 1-14, 1-16
L
port
LAN-to-phone jack 2-27 connecting to 2-30 to 2-32
Laser beam exposure warning C-26 See also RJ-21 connector
LEDs
100 port mode 1-13, 1-15
DUPLX 1-16
M
expansion slots 1-17
FDUP 1-13, 1-15 main disconnecting device warning C-9
full duplex 1-15, 1-16 maximum connection distances
half duplex 1-15, 1-16 See connection distances, maximum
interpreting 1-13 mid-mount
LRE 1-14, 1-16 See installation
port status 1-9, 1-15 to 1-16 attaching mounting brackets (telco
POST results 2-25, 3-2 rack-mount)
warning C-18
O
power connectors 1-19
overtemperature warning C-10 power on 2-25
power supply
AC power outlet 1-19
P
RPS connector 1-19
packing list 2-6 warning C-21
PC, connecting to switch 2-33 product disposal warning C-24
performance problems, solving 3-3
personnel warning C-4
Q
pinouts
10/100BASE-T ports B-2 qualified personnel warning C-4
cable, straight-through and crossover B-4
RJ-21 connector B-5
RJ-45-to-DB-25 terminal adapter B-8
R
RJ-45-to-DB-9 terminal adapter B-7 rack installation
rollover cable B-7, B-8 bracket mounting points 2-9
ports rear panel
10/100BASE-T 1-6 AC power connector 1-19
100BASE-FX 1-7 console port B-5
console 1-21 RPS connector 1-19
console connector pinouts B-5 RJ-21 connector
LRE 1-7 illustration 1-7
module 1-8 pinouts B-5
port status LEDs 1-9, 1-15 to 1-16 RJ-45 connector, console port 2-34, B-3, B-5
port status LEDs 1-9, 1-15 to 1-16 RJ-45 console port 1-18
POST results 2-25 rollover cable 2-34, B-6
power identifying B-6
connecting to 2-25 pinouts B-8
RPS
T
LED 1-12 to 1-13
RPS 300 Telco 2-16
connector 1-20 telephone network power warning
LED 1-13 See TN power warning C-13
supported switches 1-19 Telnet, and accessing the CLI 1-4
warning C-3 temperature
RPS 600 maximum for installation 2-6, A-2
connector 1-20 warning C-10
LED 1-12 temperature warning C-10
supported switches 1-19 terminal, connecting to switch 2-33
warning C-2 terminal adapter pinouts
RH-45-to-RJ-45 B-7
RJ-45-to-DB-25 B-7
S RJ-45-to-DB-9 B-6
safety C-1 terminal emulation software 2-33
SC connectors B-2 TN power warning C-13
SPEED LED 1-14, 1-16 translated warnings C-1 to C-33
stacking the chassis warning C-8
STAT LED 1-13 to 1-16
U
straight-through cable pinouts
cables UTL LED 1-13, 1-15
straight-through B-4
SunNet Manager 1-4
V
supply circuit warning C-18
switch VDSL
powering on 2-25 defined 1-1
switched ports, module 1-8 very-high-data-rate digital subscriber line
System LED 1-11 See VDSL
warnings
translated C-1 to C-33