0% found this document useful (0 votes)
42 views41 pages

Actiflo Applications (1) - Optimized

The document provides an overview of the Actiflo Pack, a high-rate clarifier used for various water treatment applications, including municipal drinking water, stormwater, and industrial wastewater treatment. It highlights the system's compact design, high treatment efficiency, and proven technology through case studies demonstrating its effectiveness in different scenarios. Additionally, it outlines expected performance metrics and benefits, making it a versatile solution for water treatment needs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views41 pages

Actiflo Applications (1) - Optimized

The document provides an overview of the Actiflo Pack, a high-rate clarifier used for various water treatment applications, including municipal drinking water, stormwater, and industrial wastewater treatment. It highlights the system's compact design, high treatment efficiency, and proven technology through case studies demonstrating its effectiveness in different scenarios. Additionally, it outlines expected performance metrics and benefits, making it a versatile solution for water treatment needs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 41

Actiflo Pack - High Rate Clarifier

APPLICATION
Fenian FENG
Technical & Product Manager
Standard Product, Veolia APAC

For Distributors, 2020


Agenda
HOW TO SELL ACTIFLO PACK
01 02
Applications Case Studies
Expected Performance

03 04 05
Benefits Sales Q&A
Arguments
MUNICIPAL
DRINKING WATER TREATMENT
STORM WATER TREATMENT
PRIMARY TREATMENT IN SEWAGE WASTEWATER TREATMENT PLANT
BACKWASH THICKENING (FILTER, BIOFILTER)
ACTIFLO ALGAE REMOVAL
APPLICATIONS INDUSTRIAL
PRIMARY TREATMENT (INTAKE WATER TREATMENT)
SECONDARY TREATMENT (MBBR EFFLUENT)
Actiflo is suitable for TERTIARY TREATMENT (PHOSPHATE REMOVAL)
applications, such as:
TERTIARY TREATMENT (HARD COD REMOVAL WITH CARBON)
HEAVY METAL REMOVAL
SOFTENING

2019 STANDARD PRODUCT TRAINING - SEA


3
MUNICIPAL
DRINKING WATER TREATMENT

Application Targets of pretreatment step:


- Surface water or groundwater can be water source
- Coagulation/Flocculation is an effective solution for
Turbidity & color removal
- It’s typically applied before filtration
- Pretreated effluent will have an impact on the stability
of filtration system
- Capacity can be varied from few to hundreds MLD

Reasons to propose Actiflo Pack:


- Extremely compact system
- Complied with French certificate of health compliance:
ACS standard
- High treatment efficiency
Source: Veolia Product - Quick treatment performance recovery
- ideal for auto operation with frequent stops and restarts
- effective in treating low temp / turbidity water
2019 STANDARD PRODUCT TRAINING - SEA - Proven technology 4
MUNICIPAL
DRINKING WATER TREATMENT

PROCESS DATA

Parameters Unit Value

m3/hr 40 - 850
Capacity
(per Unit)
MLD 1.0 - 20.5

SS in mg/L up to 500

SS out mg/L 5

Sludge concentration % 0.1 - 2

Normanton Water Treatment Plant Municipal AUS

2019 STANDARD PRODUCT TRAINING - SEA


5
MUNICIPAL
DRINKING WATER TREATMENT
CASE STUDY

2019 STANDARD PRODUCT TRAINING - SEA


6
MUNICIPAL
DRINKING WATER TREATMENT
CASE STUDY

Client Needs
- Drinking water for shower rooms
- Capacity: 1900 m3/d
- Model: 1 x APW-2 SS
- Package supplied by VWS Memsep, at 2008
- Downstream: sand filter
- Won due to Flexibility, reliability and small
- footprint of the Actiflo® Pack technology

Parameters Unit Value

SS in mg/L up to 500

The End Client:


SS out mg/L 5
Unipetrol - Orlen Group, Czech Republic (Litvinov)

2019 STANDARD PRODUCT TRAINING - SEA


7
MUNICIPAL
DRINKING WATER TREATMENT
CASE STUDY

Client Needs
- Drinking water for the food & beverage Kerry-Apt-Union
industry (fruit ingredients)
- Capacity: 2700 m3/d
- Model: 1 x APW-3
- Package supplied by VWS Memsep, at 2009
- Raw water: Raw water from Durance river
- Won due to Flexibility, reliability and small footprint of
the Actiflo® Pack technology

Parameters Unit Value

avg. 60
Inlet Turbidity NTU
Peak 1000

SS out mg/L 5 The End Client:


Kerry-Apt-Union industry, France

2019 STANDARD PRODUCT TRAINING - SEA


8
MUNICIPAL
STORM WATER TREATMENT

APPLICATION Storm water


- Stormwater is a major cause of urban flooding
- Litter or silt that enters the drains or rivers will pollute
the waters and
- May block the flow of stormwater in waterways
- High load of contaminants might decrease the facility
efficiency of drinking water system located next to the
river
- High variations of inlet conditions can be expected

Reasons to propose Actiflo Pack:


- Extremely compact system
- High treatment efficiency
- Quick treatment performance recovery
Source: Internet - ideal for auto operation with frequent stops and restarts
- effective in treating low temp / turbidity water

2019 STANDARD PRODUCT TRAINING - SEA


9
MUNICIPAL
STORM WATER TREATMENT

PROCESS DATA

Parameters Unit Value

m3/hr 40 - 850
Capacity
(per Unit)
MLD 1.0 - 20.5

SS in mg/L up to 500

SS removal % 90

Sludge concentration % 0.1 - 2

Source: Veolia Product

2019 STANDARD PRODUCT TRAINING - SEA


10
MUNICIPAL
STORM WATER TREATMENT
CASE STUDY

Client Needs
- Stormwater treatment application
- Compact system requried
- Capacity: 320MLD
- Plant built in 2006

Parameters Unit Value

SS in mg/L up to 1500

SS out mg/L 50

The End Client:


Illawarra, Sydney, Australie

2019 STANDARD PRODUCT TRAINING - SEA


11
MUNICIPAL - INDUSTRIAL
PRIMARY TREATMENT
Sewage Wastewater
APPLICATION - Sewage is generated in residential, commercial and
industrial area
- It includes household waste liquid from toilets, baths,
showers, and kitchens draining into sewers
- In many areas, sewage also includes liquid waste from
industry and commerce.
- Transferring thru long distance pipelines, the main
pollutants are: heavy particles, Oil & Grease which
needs to be removed before feeding into secondary
biological system to avoid the sedimentation in
downstreams.
- Normally quite big capacity for Municipal plants, and
industrial plan could be smaller

Reasons to propose Actiflo Pack:


Source: Internet
- Extremely compact system
- Tolerate high inlet loading fluctuation
- Effective in treating low temp water
2019 STANDARD PRODUCT TRAINING - SEA
12
- High treatment efficiency
MUNICIPAL - INDUSTRIAL
PRIMARY TREATMENT IN SEWAGE TREATMENT PLANT

PROCESS DATA

Parameters Unit Value

m3/hr 40 - 850
Capacity
(per Unit)
MLD 1.0 - 20.5

SS in mg/L up to 500

SS out mg/L 50 - 100

Sludge concentration % 0.1 - 2


Source: Veolia Project

2019 STANDARD PRODUCT TRAINING - SEA


13
MUNICIPAL - INDUSTRIAL
PRIMARY TREATMENT IN SEWAGE TREATMENT PLANT
CASE STUDY

Client Needs
- Compact design required due to very limited space
- High treatment efficiency to meet with strict
regulations
- 3 in 1: primary treatment, storm flow treatment (wet
weather) and biofilter backwash water treatment
(Biostyr®)
- Plant capacity: 520MLD

Parameters Unit Value

SS in mg/L up to 1500

The End Client:


SS out mg/L 50
Aïre wastewater treatment plant, Geneva, Switzerland

2019 STANDARD PRODUCT TRAINING - SEA


14
MUNICIPAL - INDUSTRIAL
PRIMARY TREATMENT IN SEWAGE TREATMENT PLANT
CASE STUDY

Client Needs
- Sewage primary treatment
- Capacity: 80m3/hr
- Model: 1 x APWW-1
- Package supplied by VWS Iberica, at 2007

- Won due to Flexibility, reliability and small footprint


of the Actiflo® Pack technology

Parameters Unit Value

SS in mg/L 100 -260

The End Client:


SS out mg/L > 80%
EDAR Gran Canaria (Sureste)

2019 STANDARD PRODUCT TRAINING - SEA


15
MUNICIPAL - INDUSTRIAL
PRIMARY TREATMENT IN SEWAGE TREATMENT PLANT
CASE STUDY

Client Needs
- 3 000 m3/d intake water from the Massawippi River.
- High variations of the raw water quality required
frequent backwashing of the sand filters, thus causing
production drawbacks.
- Actiflo Pack was proposed due to the benefits of:•
Process compactness, Treatment stability, Operation
simplicity, Minimum construction costs.

Parameters Unit Value

Turbidity in NTU 5.8 - 250

The End Client:


Turbidity out NTU 0.2 - 4.7
Scott Paper Ltd.,Lennoxville, QC

2019 STANDARD PRODUCT TRAINING - SEA


16
INDUSTRIAL
PRIMARY WASTEWATER TREATMENT
CASE STUDY

Client Needs
- MicroE industry, for TSS and Silicon removal
- Compact design required due to very limited space,
for indoor installation
- High treatment efficiency to meet with strict
regulations
- Plant built at 2006, then Ph2, Ph3 followed
- Capacity: 40m3/hr

CODCr BOD5 TSS

Actiflo Influent - - 500

Actiflo Effluent - - <20


The End Client:
Samsung Plant, Suzhou, China

2019 STANDARD PRODUCT TRAINING - SEA


17
INDUSTRIAL
PRIMARY WASTEWATER TREATMENT
CASE STUDY

Client Needs
- Industry : Semiconductor – Silicon wafer manufacture
- Equipment : Actiflo + Hydrotech Discfilter (Actidisk), MF, RO
- Application : High TSS water from silicon cutting & polishing
process
- Capacity: 60m3/hr
- Goal : SDI15 < 3; Turbidity < 1 NTU

- Client Requirements:
- Packaged Solution with extremely small footprint (no space
available at existing WW treatment plant)
- Treat high TSS, “Stop & Go” operation, quick on-line treatment
- Fully automatic, user friendly with little or no operator input

The End Client:


LG Siltron P3, Gumi, S. Korea

2019 STANDARD PRODUCT TRAINING - SEA


18
INDUSTRIAL
PRIMARY WASTEWATER TREATMENT
CASE STUDY

The End Client:


LG Siltron P3, Gumi, S. Korea

2019 STANDARD PRODUCT TRAINING - SEA


19
MUNICIPAL
ALGAE REMOVAL
Algae:
APPLICATION
- 'algae' is a broad term including organisms of widely varying sizes,
growth rates, and nutrient requirements
- Freshwater algal blooms are the result of an excess of nutrients,
particularly some phosphates (>0.1ppm)
- Algae tend to grow very quickly under high nutrient availability, but
each alga is short-lived, and the result is a high concentration of
dead organic matter which starts to decay.
- The decay process consumes dissolved oxygen in the water,
resulting in hypoxic conditions. Without sufficient dissolved
oxygen in the water, animals and plants may die off in large
numbers.
- During the summer months, effluent can be highly loaded with
algae;

Reasons to propose Actiflo Pack:


- Extremely compact system
- As good as DAF performance for Algae removal
Source: Internet
- Proven technology
2019 STANDARD PRODUCT TRAINING - SEA
20
MUNICIPAL
ALGAE REMOVAL

PROCESS DATA

Parameters Unit Value

m3/hr 40 - 850
Capacity
(per Unit)
MLD 1.0 - 20.5

SS in mg/L up to 500

SS out mg/L 50

Sludge concentration % 0.1 - 2

Source: Veolia Project

2019 STANDARD PRODUCT TRAINING - SEA


21
MUNICIPAL
ALGAE REMOVAL
CASE STUDY

2019 STANDARD PRODUCT TRAINING - SEA


22
Source: Veolia Pilot Test
MUNICIPAL
ALGAE REMOVAL
CASE STUDY

2019 STANDARD PRODUCT TRAINING - SEA


23
Source: Veolia Pilot Test
MUNICIPAL - INDUSTRIAL
SECONDARY TREATMENT (MBBR EFFLUENT)

APPLICATION

MBBR Effluent:
- Typically low TSS effluent thanks to MBBR biofilm
technology
- Fine, light biomass in MBBR effluent
- For proper separation, chemical dosing might be
required.

Reasons to propose Actiflo Pack:


- Extremely compact system
- Proven technology
- MBBR not requires biomass recirculation, no risk of
microsand accumulation.

Source: Veolia Product

2019 STANDARD PRODUCT TRAINING - SEA


24
MUNICIPAL - INDUSTRIAL
SECONDARY TREATMENT (MBBR EFFLUENT)

PROCESS DATA

Parameters Unit Value

m3/hr 40 - 850
Capacity
(per Unit)
MLD 1.0 - 20.5

SS in mg/L 300

SS out mg/L 20 - 50

Sludge concentration % 0.1 -2

Source: Veolia Product

2019 STANDARD PRODUCT TRAINING - SEA


25
INDUSTRIAL
TERTIARY TREATMENT (PHOSPHATE REMOVAL)

APPLICATION Phosphate precipitation:


- Chemical precipitation is an effective solution for TP
removal
- Low effluent TSS required
- Only active phosphate to be precipated
- Salt of Iron, Alum, or Calcium could react with
orthophosphate to form Phosphate precipitation
- Precipitation can be easily separated in Multiflo

Reasons to propose Multiflo Pack:


- Extremely compact system
- High treatment efficiency
- Quick treatment performance recovery
- ideal for auto operation with frequent stops and restarts
- effective in treating low temp / turbidity water
- Proven technology

2019 STANDARD PRODUCT TRAINING - SEA


26
INDUSTRIAL
TERTIARY TREATMENT (PHOSPHATE REMOVAL)

PROCESS DATA

Parameters Unit Value

m3/hr 40 - 850
Capacity
(per Unit)
MLD 1.0 - 20.5

SS in mg/L 50

SS out mg/L 10

TP out mg/L 0.3 - 1.0

Sludge concentration % 0.1 - 2.0 Source: Veolia Product

2019 STANDARD PRODUCT TRAINING - SEA


27
INDUSTRIAL
TERTIARY TREATMENT (HARD COD REMOVAL WITH CARBON)

APPLICATION

Refractory COD:
- Industrial effluent are often contaminated with refractory organic pollutants, having complex molecular structure,
and varying biodegradability.
- Refractory COD not be able to easily biodegraded.
- MultifloCarb with Powder Activated Carbon dosing is more effective in some cases

Reasons to propose Actiflo Pack:


- Extremely compact system
- High treatment efficiency
- Quick treatment performance recovery
- ideal for auto operation with frequent stops and restarts
- effective in treating low temp / turbidity water
- Proven technology

2019 STANDARD PRODUCT TRAINING - SEA


28
INDUSTRIAL
TERTIARY TREATMENT (HARD COD REMOVAL WITH CARBON)

PROCESS DATA

Parameters Unit Value

m3/hr 30 - 430
Capacity
(per Unit)
MLD 0.75 - 10

SS in mg/L 10

COD out mg/L Subject to Carbon dosage

Sludge concentration % 0.1 - 2.0

Source: Veolia Project - Huntsman Qingdao Project, China

2019 STANDARD PRODUCT TRAINING - SEA


29
INDUSTRIAL
TERTIARY TREATMENT (HARD COD REMOVAL WITH CARBON)
CASE STUDY

Client Needs
- Client name: Huntsman Textile Effects Qingdao
- High Soluble COD in secondary clarifier effluent in
existing WWTP, tCOD 800ppm having 790ppm
Soluble COD
- Discharge requires COD <200ppm, increased to
100ppm 2 yrs later after project executed;
- 1000m3/day capacity
- There are 3 Granular Activated Carbon filters in
operation, however clients gave up due to extremely
high OPEX. Yearly More than RMB 6Million for
Granular Activated Carbon replacement only!!!
- ActifloCarb was proposed to replace the existing
GAC filters, with lower OPEX.
The End Client:
- Project awarded due to small footprint, easy
Huntsman Qingdao, China
operation, high treatment performance, and low
OPEX.
2019 STANDARD PRODUCT TRAINING - SEA
30
INDUSTRIAL
TERTIARY TREATMENT (HARD COD REMOVAL WITH CARBON)
CASE STUDY

System performance:
- 1x AFP2 (APWW2)

Parameters Unit Value

COD in mg/L 800

COD out mg/L <100

PAC dosage kg/hr 60-90

The End Client:


Huntsman Qingdao, China

2019 STANDARD PRODUCT TRAINING - SEA


31
INDUSTRIAL
HEAVY METAL REMOVAL

APPLICATION

heavy metal precipitation:


- Follow conventional metals precipitation chemistry -
raise pH with lime or caustic
- Sulfide addition may be necessary
- Separate reaction tank
-

Reasons to propose Actiflo Pack:


- Extremely compact system
- High treatment efficiency
- Quick treatment performance recovery
- ideal for auto operation with frequent stops and restarts
- effective in treating low temp / turbidity water
- Proven technology

2019 STANDARD PRODUCT TRAINING - SEA


32
INDUSTRIAL
HEAVY METAL REMOVAL

PROCESS DATA

Parameters Unit Value

m3/hr 40 - 850
Capacity
(per Unit)
MLD 1.0 - 20.5

SS in mg/L 50

SS out mg/L 10

Sludge concentration % 0.1 - 2.0

2019 STANDARD PRODUCT TRAINING - SEA


33
INDUSTRIAL
HEAVY METAL REMOVAL
CASE STUDY

Client Needs
- Gold mining
- High As, TSS, COD and Heavy Metals
- Wastewater treatment for re-use
- Supplied 3x APWW 3, by VWS Envig at 2009
- Capacity: 7680m3/day

CODCr TSS As TDS

Actiflo Influent 540 76.5 5.6 4820

Actiflo Effluent WHO & CHIR standard


The End Client:
Anglo Gold Ashanti Ghana (Obuasi)

2019 STANDARD PRODUCT TRAINING - SEA


34
INDUSTRIAL
HEAVY METAL REMOVAL
CASE STUDY

Client Needs
- Raw Water Characteristics:
- Process Water Flow: 2,300 – 5,700 m3/h
- With Stormwater Runoff Flow: Up to 34,000 m3/h
- pH: 1.5 – 5.0
- TSS: 200 – 2,500 mg/l
- O&G: 20 – 190 mg/l
- Total Cu: 0 – 140 µg/l
- Total Ni: 0 – 140 µg/l
- Total Zn: 0 – 5 mg/l
-
- Treated Water Requirements:
- pH: 6–9
- TSS: < 17 mg/l Monthly Average & < 43 mg/l Daily Average
The End Client:
- O&G: < 5 mg/l Monthly Average & < 12 mg/l Daily Average
International Steel Group (ISG), USA
- Total Cu: < 6.1 µg/l
- Total Ni: < 20 µg/l
-
2019 STANDARD PRODUCT TRAINING - SEA
35
INDUSTRIAL
HEAVY METAL REMOVAL
CASE STUDY

The End Client:


Mirror speed: 150 m/hr Mirror speed: 180 m/hr
International Steel Group (ISG), USA

2019 STANDARD PRODUCT TRAINING - SEA


36
INDUSTRIAL
SOFTENING
Softening:
APPLICATION - Water softening is the removal of calcium, magnesium,
and certain other metal cations in hard water.
- Hard water leads to the buildup of limescale, which can
foul plumbing, and promote galvanic corrosion.
- In industrial scale water softening plants, the effluent
flow from the re-generation process can precipitate
scale that can interfere with sewage systems.
- Lime softening is an effective solution to remove
hardness.

Reasons to propose Actiflo Pack:


- Extremely compact system
- High treatment efficiency
- Quick treatment performance recovery
Source: Internet - ideal for auto operation with frequent stops and restarts
- effective in treating low temp / turbidity water
- Proven technology
2019 STANDARD PRODUCT TRAINING - SEA
37
INDUSTRIAL
SOFTENING

PROCESS DATA

Parameters Unit Value

m3/hr 40 - 850
Capacity
(per Unit)
MLD 1.0 - 20.5

SS in mg/L 50

SS out mg/L 10

Sludge concentration % 0.1 - 2.0

Source: Veolia Product

2019 STANDARD PRODUCT TRAINING - SEA


38
ACTIFLO APPLICATIONS

2019 STANDARD PRODUCT TRAINING - SEA


39
CONCLUSION
ACTIFLO IS SUITABLE

MUNICIPAL APPLICATIONS INDUSTRIAL APPLICATIONS ALGAE REMOVAL

CONCLUSION
ACTIFLO IS PROPOSED, BECAUSE OF:
EXTREMELY SMALL QUICK TREATMENT EFFECTIVE IN TREATMENT OF
FOOTPRINT PERFORMANCE RECOVERY LOW TEMP/TURBIDITY WATER

HIGH TREATMENT FREQUENT STOPS AND


ROBUST
PERFORMANCE RESTARTS

PRE-ASSEMBLE IN
PROVEN TECHNOLOGY INTEGRATION WITH OTHER WORKSHOP, STANDARD
TECHNOLOGIES
- ACTIFLO CARB
2019 STANDARD PRODUCT TRAINING - SEA
- ACTIFLO SOFTENING 40
Q
A

2019 STANDARD PRODUCT TRAINING - SEA


41

You might also like