TRUNNION LOAD CHECK CALCULATION
Select Parent Pipe Nominal Size 600 [mm]
Select Parent Pipe Sch./mm,(tp)= 12.7 [mm]
Select Trunion Pipe Nominal Size 355.6 [mm]
Select Trunion Pipe Sch./mm 7.93 [mm]
Corrosion Allowance (mm), C= 3.18
Reinforcement Pad Thk.(mm), tr= 0
Line Design Pressure [N/mm2], P=
1.517
Note: Barg/10 gives N/mm )
2
Design Temp. (OC) 34
Hot Stress Allowable (MPa),Sh 99.29
Loading Data
Vertical load, FLONG = 17000 [N] Circumferential load, FCIRCUM =
Axial load, FAXIAL = 38500 [N] Moment arm, L =
Long. Bending Mom. ML= FLONG * L [N-mm]
1.04E+07 [N-mm]
Circum. Bending Mom. MC= FCIRCUM x L [N-mm]
4.29E+06 [N-mm]
Trunion Loading FL = ML/(π*r2) [N/mm]
104.93 [N/mm]
FA = FAXIAL/(2*π*r) [N/mm]
34.46 [N/mm]
Header Pipe Stresses SL = 1.17*FL*R0.5/t1.5 [MPa]
72.39 [MPa]
SA = 1.5*1.17*FA*R0.5/t1.5 [MPa]
32.13 [MPa]
COMBINED ALLOWABLE STRESS CHECK FOR PARENT PIPE
SL + SA + SLP = 128.43 [MPa] <= 1.5 x Sh =
SC + SA + SCP = 139.55 [MPa] <= 1.5 x Sh =
Trunion Stresses SL = (ML2+MC2)0.5 / ((π(d4-di4)/ (32 d)))
2.55 [MPa]
ALLOWABLE STRESS CHECK FOR TRUNION
SL = 2.55 [MPa] <= Sh =
HECK CALCULATION
Parent Pipe Radius, R= 300 [mm]
Trunion Pipe Radius, r= 177.8 [mm]
Trunion Pipe I.D., di= 42.84 [mm]
Total Wall Thk., t= tp-C+tr [mm]
9.52 [mm]
mferential load, FCIRCUM = 7000 [N]
Moment arm, L = 613 [mm]
Long. Press. Stress [SLP] = P*R/(2*t) [MPa]
23.90 [MPa]
Circum. Press. Stress [SCP] = P*R/t [MPa]
47.80 [MPa]
FC = MC/(π*r2) [N/mm]
43.21 [N/mm]
SC = 2.34*FC*R0.5/t1.5 [MPa]
59.62 [MPa]
FOR PARENT PIPE
149 [MPa] PASSED
149 [MPa] PASSED
[MPa]
99 [MPa] PASSED