0% found this document useful (0 votes)
66 views4 pages

Trunion Load Calculation

The document outlines the trunnion load check calculations for a piping system, detailing parameters such as pipe sizes, wall thicknesses, design pressures, and loads. It includes calculations for vertical, circumferential, and axial loads, as well as stress checks for both the parent and trunnion pipes. The results indicate that the calculated stresses are within allowable limits, confirming the integrity of the design.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views4 pages

Trunion Load Calculation

The document outlines the trunnion load check calculations for a piping system, detailing parameters such as pipe sizes, wall thicknesses, design pressures, and loads. It includes calculations for vertical, circumferential, and axial loads, as well as stress checks for both the parent and trunnion pipes. The results indicate that the calculated stresses are within allowable limits, confirming the integrity of the design.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

TRUNNION LOAD CHECK CALCULATION

Select Parent Pipe Nominal Size 600 [mm]

Select Parent Pipe Sch./mm,(tp)= 12.7 [mm]

Select Trunion Pipe Nominal Size 355.6 [mm]

Select Trunion Pipe Sch./mm 7.93 [mm]

Corrosion Allowance (mm), C= 3.18

Reinforcement Pad Thk.(mm), tr= 0

Line Design Pressure [N/mm2], P=


1.517
Note: Barg/10 gives N/mm )
2

Design Temp. (OC) 34

Hot Stress Allowable (MPa),Sh 99.29

Loading Data

Vertical load, FLONG = 17000 [N] Circumferential load, FCIRCUM =

Axial load, FAXIAL = 38500 [N] Moment arm, L =

Long. Bending Mom. ML= FLONG * L [N-mm]


1.04E+07 [N-mm]

Circum. Bending Mom. MC= FCIRCUM x L [N-mm]


4.29E+06 [N-mm]

Trunion Loading FL = ML/(π*r2) [N/mm]


104.93 [N/mm]

FA = FAXIAL/(2*π*r) [N/mm]
34.46 [N/mm]

Header Pipe Stresses SL = 1.17*FL*R0.5/t1.5 [MPa]


72.39 [MPa]
SA = 1.5*1.17*FA*R0.5/t1.5 [MPa]
32.13 [MPa]
COMBINED ALLOWABLE STRESS CHECK FOR PARENT PIPE

SL + SA + SLP = 128.43 [MPa] <= 1.5 x Sh =

SC + SA + SCP = 139.55 [MPa] <= 1.5 x Sh =

Trunion Stresses SL = (ML2+MC2)0.5 / ((π(d4-di4)/ (32 d)))


2.55 [MPa]

ALLOWABLE STRESS CHECK FOR TRUNION

SL = 2.55 [MPa] <= Sh =


HECK CALCULATION

Parent Pipe Radius, R= 300 [mm]


Trunion Pipe Radius, r= 177.8 [mm]

Trunion Pipe I.D., di= 42.84 [mm]


Total Wall Thk., t= tp-C+tr [mm]
9.52 [mm]

mferential load, FCIRCUM = 7000 [N]

Moment arm, L = 613 [mm]

Long. Press. Stress [SLP] = P*R/(2*t) [MPa]


23.90 [MPa]

Circum. Press. Stress [SCP] = P*R/t [MPa]


47.80 [MPa]

FC = MC/(π*r2) [N/mm]
43.21 [N/mm]

SC = 2.34*FC*R0.5/t1.5 [MPa]
59.62 [MPa]
FOR PARENT PIPE

149 [MPa] PASSED

149 [MPa] PASSED

[MPa]

99 [MPa] PASSED

You might also like