Question 1
Incorrect
Points out of 1.00
How does Policy-based High Availability (PBHA) simplify the
configuration, management and monitoring of HA with SVC and
FlashSystem?
Through the use of Storage partitions, policies and volume
groups.
Through the use of AI and volume groups.
Through the use of Storage partitions, AI and volume
groups.
Through the use of policies and volume groups.
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 1/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 2
Correct
Points out of 1.00
Back Next
As of mid-2023, with Storage Virtualize 8.6.0, or greater, what
new cyber resiliency feature is available for all members of the
IBM FlashSystem and SAN Volume Controller families?
There are no new universally available cyber resiliency
features for the SAN Volume Controller family
QRadar
Ransomware Threat Detection
Safeguarded Copy
Question 3
Incorrect
Points out of 1.00
A client asks about the number of HBA cards that are supported
by a single SAN Volume Controller SV3 node. What is the
correct answer?
4
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 2/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 4
Correct
Points out of 1.00
Back Next
What important components in the SAN Volume Controller SV3
nodes are hot pluggable?
Card cages and batteries
Batteries, boot drives, Card cages
Batteries and boot drives
Card cages and boot drives
Question 5
Correct
Points out of 1.00
How can the reliability of a SAN Volume Controller (SVC) cluster
be further enhanced?
With the use of hot spare node(s).
By adding a third, or fourth, boot drive.
By implementing an Enhanced Stretched Cluster.
By ordering the “enhanced reliability cluster” (ERC)
feature.
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 3/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 6
Incorrect
Points out of 1.00
Back Next
A seller is speaking with an IT Director at a university who has
been told their department must establish an HA configuration
between two buildings on campus. The Director explains they
have numerous storage arrays from different vendors and none
of them can easily communicate with each other. The Director
also explains they do not have the budget to acquire new
storage systems to solve the problem. What unique use case
could the seller suggest that would inexpensively, and uniquely,
solve the university’s problem?
SAN Volume Controller Stretched Cluster
SAN Volume Controller using PBHA
SAN Volume Controller using Safeguarded Copy
SAN Volume Controller using HyperSwap
Question 7
Incorrect
Points out of 1.00
AIOps, refers to the strategic use of AI, machine learning (ML),
and machine reasoning (MR) technologies throughout IT
operations to simplify and streamline processes and optimize
the use of IT resources. What IBM software, used with SAN
Volume Controller and FlashSystem arrays provides AIOps?
Storage Protect
Storage Virtualize
Storage Insights
Storage Assurance
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 4/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 8
Correct
Points out of 1.00
Back Next
SAN Volume Controller includes powerful cloud software that
provides AI-based predictive analytics and proactive health
monitoring. What is the name of this software?
IBM Storage Connect
IBM Multicloud Manager
IBM Storage Control
IBM Storage Insights
Question 9
Correct
Points out of 1.00
When an organization uses SAN Volume Controller what one
important feature is still the responsibility of the third-party
storage to provide?
3-Site Data Copies
Ransomware Threat Detection (RTD)
Metro/Global Mirror (Remote copy)
DRAID (Distributed Redundant Array of Inexpensive
Drives) protection
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 5/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 10
Correct
Points out of 1.00
Back Next
The Easy Tier functionality in Storage Virtualize is impressive. It
employs AI to automatically optimize performance by moving
frequently accessed data to the fastest storage tier. Why is Easy
Tier even more impressive when it is used with SAN Volume
Controller?
It can move Safeguarded Copy snapshots to a faster tier
It uses policy-based rules when employed in a virtualized
environment
It is 27% faster than when used with a single storage array
It can tier between virtualized arrays to enhance all
systems
Question 11
Incorrect
Points out of 1.00
What High Availability (HA) environment can automatically
mirror Safeguarded Copies when working with a SAN Volume
Controller environment?
Policy-based Replication (PBR)
Policy-based High Availability (PBHA)
HyperSwap
Enhanced Stretched Cluster
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 6/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 12
Correct
Points out of 1.00
Back Next
A client asks a seller, “What represents the key value
propositions for SAN Volume Controller?” What response is
correct?
Simplified data migrations, lower storage utilization, and
higher total cost of ownership
Underlying storage keeps its own sets of enhanced
functions managed separately, and simplified data
migrations.
Improved storage utilization, simplified data migrations,
and increased response times
SVC provides common management, advanced
functions, improved storage utilization, and simplified
data migrations.
Question 13
Correct
Points out of 1.00
A client is expressing concern over basing their storage
infrastructure on a new cutting edge virtualization technology.
What SAN Volume Controller (SVC) celebration should a seller
point out to the client?
SVC had its 20th Anniversary in 2023
SVC had its 16th Anniversary in 2023
SVC had its 15th Anniversary in 2023
SVC had its 18th Anniversary in 2023
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 7/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 14
Correct
Points out of 1.00
Back Next
What important components in the SAN Volume Controller SA2
nodes are not externally accessible?
Boot drives and host adaptor cards
Batteries and host adapter cards
Host adapter cards and batteries
Battery and boot drives
Question 15
Correct
Points out of 1.00
A client seems genuinely interested in understanding the base
software that provides rich functionality in all SAN Volume
Controller models. What is the name of that software?
IBM Storage Control
IBM Storage Accelerate
IBM Storage Virtualize
IBM Storage Discover
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 8/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 16
Correct
Points out of 1.00
Back Next
During a client meeting, a seller is asked, what is the maximum
distance a Stretched Cluster can be spread across. What is the
best response?
300km, and it is strongly promoted as a great distance
10km
200km
300km, but it is not encouraged due to latency issues
Question 17
Correct
Points out of 1.00
During a meeting, a seller is explaining what helps make IBM’s
Easy Tier so efficient and economical, even when only small
amounts of high-performance flash storage are available. What
ability helps Easy Tier be efficient and economical?
Works on a sub-LUN (Logical Unit Number) basis
Can differentiate between 7.2K and 10K HDDs
Works only with IBM block storage devices
Uses Artificial Intelligence rather than Policies
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 9/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 18
Correct
Points out of 1.00
Back Next
A seller assures a client that SAN Volume Controller (SVC)
provides a wide range of features/abilities. The seller points out
that IBM has configured SVCs to support sufficient memory to
handle all the various features/abilities. What is the maximum
amount of cache that is supported in a SAN Volume Controller
SA2 node?
128GB
512GB
768GB
384GB
Question 19
Incorrect
Points out of 1.00
A client has two SVC SA2 nodes at a primary site where they
have several third-party storage arrays. They also have two SVC
SA2 nodes at a second site, which is 80km away, which also
has several storage arrays. The client wishes to create an HA
configuration between the two sites. As of June of 2024, what
is the recommended solution for a performance optimized HA
configuration between two sites?
HyperSwap
Policy-based Replication (PBR)
Stretched Cluster
Policy-based High Availability (PBHA)
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 10/11
2025. 03. 24. 13:09 Quiz [SVC L2]: Attempt review
Question 20
Incorrect
Points out of 1.00
Back Next
What is the minimum amount of cache, in SAN Volume
Controller SV3, that will provide 100% memory bandwidth for
the node?
1536GB
512GB
768GB
1024GB
https://learn.ibm.com/mod/quiz/review.php?attempt=3796116&cmid=308723 11/11