AIB-F-TL-02 REV00
Autoliv India Pvt. Ltd,
LABORATORY TEST REPORT Hoskote Industrial Estate
Bangalore – 562114
Tel: +91 80 30601300
ISO 12097-2:1996(E), Manufactured
TO No. 18035502 Test specification NA
GB/T 19949.2 - 2005 On
Part 644632800A,
SAB RH & LH Part No Received on 10-Jul-18
Description 644632500A
17-Jul-2018 to
Customer TATA Reason of test PV Testing Test Date
14-Sep-2018
Model Q501 Originator Mahesh Gadagooli Tested By Lokesh
Humidity Test
Scope of the test:
Product Validation
Test Method:
- Environmental chamber capable of maintaining 38°C and 90±5% relative humidity, and large enough to permit
air circulation between the test samples
- Condition the test sample, at 38°C±2°C and 90±5% relative humidity for 400 hours ± 8hours.
- The test samples shall then be room conditioned for a minium of eight hours.
- After humidity test, condition and deploy IC modules as specified in the module
deployment test as per Clause 1.1
Acceptance Criteria:
- After the test, the voltage drop between the electrical contact points shall not be more than 150mV maximum at
a current of 1 Ampere
- The post deployment requirements as per clause 1.1
- SAB & any of its component shall not exhibit any fragmentation or separation of pieces from its attachment /
assembly.
- The fabric shall not rip, tear, separate or illustrate any damage in the material or seam
- The tear seam opening time should be as per specifications as mentioned in The design document as agreed by
The SAB supplier, Restraints integrator and TML.
- The airbag deployment time should be per specifications as mentioned in The design specifications by TML and
airbag system integrator
- component & assy should maintain structural integrity.
Prepared By Chandra Naik Checked By Anupam Approved By Naveen Raj Judgement
Sign Sign Sign Conforms
Non Conforms
Date 22-Sep-18 Date 24-Sep-18 Date 24-Sep-18 Completed
The information in this report is confidential and may not be reproduced or issued to a third party without the written permission of Autoliv
If permission is granted the report must be reproduced in full (1 of 5)
AIB-F-TL-02 REV00
Autoliv India Pvt. Ltd,
LABORATORY TEST REPORT Hoskote Industrial Estate
Bangalore – 562114
Tel: +91 80 30601300
ISO 12097-2:1996(E), Manufactured
TO No. 18035502 Test specification NA
GB/T 19949.2 - 2005 On
Part 644632800A,
SAB RH & LH Part No Received on 10-Jul-18
Description 644632500A
17-Jul-2018 to
Customer TATA Reason of test PV Testing Test Date
14-Sep-2018
Model Q501 Originator Mahesh Gadagooli Tested By Lokesh
Remarks if any:
NIL
Test Setup:
Test Observation:
Sample ID TP-181535640 TP-181535641 TP-181535642 TP-181535643 TP-181535644
Specification Actual Actual Actual Actual Actual
Conditioning
+85 / -35 / +23 +85 -35 +23 +85 -35
Temperature
Shall not rip, tear,
Fabric OK OK OK OK OK
damage in seam
Component and should maintain
OK OK OK OK OK
Assy structural integrity.
fragmentation or
Not allowed OK OK OK OK OK
separation
Cushion damage Not allowed OK OK OK OK OK
remain attached and
Module label OK OK OK OK OK
legible
Specification Sample ID TP-181535645
Conditioning
+85 / -35 / +23 +23
Temperature
Shall not rip, tear,
Fabric OK
damage in seam
Component and should maintain
OK
Assy structural integrity.
fragmentation or
Not allowed OK
separation
Cushion damage Not allowed OK
remain attached and
Module label OK
legible
The information in this report is confidential and may not be reproduced or issued to a third party without the written permission of Autoliv
If permission is granted the report must be reproduced in full (2 of 5)
AIB-F-TL-02 REV00
Autoliv India Pvt. Ltd,
LABORATORY TEST REPORT Hoskote Industrial Estate
Bangalore – 562114
Tel: +91 80 30601300
ISO 12097-2:1996(E), Manufactured
TO No. 18035502 Test specification NA
GB/T 19949.2 - 2005 On
Part 644632800A,
SAB RH & LH Part No Received on 10-Jul-18
Description 644632500A
17-Jul-2018 to
Customer TATA Reason of test PV Testing Test Date
14-Sep-2018
Model Q501 Originator Mahesh Gadagooli Tested By Lokesh
Test Photos:
TP-181535640 RH HT
Before test
After test
No abnormalities observed on No abnormalities observed on Cushion
inflator
TP-181535641 RH CT
Before test
After test
No abnormalities observed on No abnormalities observed on Cushion
inflator
The information in this report is confidential and may not be reproduced or issued to a third party without the written permission of Autoliv
If permission is granted the report must be reproduced in full (3 of 5)
AIB-F-TL-02 REV00
Autoliv India Pvt. Ltd,
LABORATORY TEST REPORT Hoskote Industrial Estate
Bangalore – 562114
Tel: +91 80 30601300
ISO 12097-2:1996(E), Manufactured
TO No. 18035502 Test specification NA
GB/T 19949.2 - 2005 On
Part 644632800A,
SAB RH & LH Part No Received on 10-Jul-18
Description 644632500A
17-Jul-2018 to
Customer TATA Reason of test PV Testing Test Date
14-Sep-2018
Model Q501 Originator Mahesh Gadagooli Tested By Lokesh
TP-181535642 RH RT
Before test
After test
No abnormalities observed on No abnormalities observed on Cushion
inflator
TP-181535643 LH HT
Before test
After test
No abnormalities observed on No abnormalities observed on Cushion
inflator
The information in this report is confidential and may not be reproduced or issued to a third party without the written permission of Autoliv
If permission is granted the report must be reproduced in full (4 of 5)
AIB-F-TL-02 REV00
Autoliv India Pvt. Ltd,
LABORATORY TEST REPORT Hoskote Industrial Estate
Bangalore – 562114
Tel: +91 80 30601300
ISO 12097-2:1996(E), Manufactured
TO No. 18035502 Test specification NA
GB/T 19949.2 - 2005 On
Part 644632800A,
SAB RH & LH Part No Received on 10-Jul-18
Description 644632500A
17-Jul-2018 to
Customer TATA Reason of test PV Testing Test Date
14-Sep-2018
Model Q501 Originator Mahesh Gadagooli Tested By Lokesh
TP-181535644 LH CT
Before test
After test
No abnormalities observed on No abnormalities observed on Cushion
inflator
TP-181535645 LH RT
Before test
After test
No abnormalities observed on No abnormalities observed on Cushion
inflator
The information in this report is confidential and may not be reproduced or issued to a third party without the written permission of Autoliv
If permission is granted the report must be reproduced in full (5 of 5)