0% found this document useful (0 votes)
9 views

xrs10p

The document is an installation and operation manual for the XRS10P powered loudspeaker by Australian Monitor, detailing important safety information and operational guidelines. It includes specifications, features, and instructions for proper use and maintenance of the speaker. The manual emphasizes safety precautions to prevent electric shock and equipment damage while providing technical details about the speaker's components and performance capabilities.

Uploaded by

basariteknik2024
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9 views

xrs10p

The document is an installation and operation manual for the XRS10P powered loudspeaker by Australian Monitor, detailing important safety information and operational guidelines. It includes specifications, features, and instructions for proper use and maintenance of the speaker. The manual emphasizes safety precautions to prevent electric shock and equipment damage while providing technical details about the speaker's components and performance capabilities.

Uploaded by

basariteknik2024
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

SERVICE INFORMATION

XRS10P
POWERED LOUDSPEAKER

CONTENTS:

OPERATION MANUAL

SCHEMATIC DIAGRAM

Australian Monitor
1 Clyde Street, Silverwater NSW 2128 Australia
+61 2 9647 1411
www.australianmonitor.com.au
XRS SERIES
POWERED AND PASSIVE LOUDSPEAKERS
INSTALLATION AND OPERATION MANUAL
IMPORTANT SAFETY INFORMATION

1. Save the carton and packing material even if the equipment has 13. Do not block fan intake or exhaust ports. Do not operate equipment
arrived in good condition. Should you ever need to ship the unit, use on a surface or in an environment which may impede the normal flow
only the original factory packing. of air around the unit, such as a bed, rug, weathersheet, carpet,
or completely enclosed rack. If the unit is used in an extremely dusty
2. Read all documentation before operating your equipment. Retain or smoky environment, the unit should be periodically “blown free”
all documentation for future reference. of foreign matter.
3. Follow all instructions printed on unit chassis for proper operation. 14. Do not remove the cover. Removing the cover will expose you
to potentially dangerous voltages. There are no user serviceable
4. Do not spill water or other liquids into or on the unit, or operate
parts inside.
the unit while standing in liquid.
15. Do not drive the inputs with a signal level greater than that required
5. Make sure power outlets conform to the power requirements listed
to drive equipment to full output.
on the back of the unit.
16. Do not connect the inputs / outputs of amplifiers or consoles to any
6. Do not use the unit if the electrical power cord is frayed or broken.
other voltage source, such as a battery, mains source, or power supply,
The power supply cords should be routed so that they are not likely
regardless of whether the amplifier or console is turned on or off.
to be walked on or pinched by items placed upon or against them,
paying particular attention to cords and plugs, convenience 17. Do not run the output of any amplifier channel back into another
receptacles, and the point where they exit from the appliance. channel’s input. Do not parallel- or series-connect an amplifier output
with any other amplifier output. Australian Monitor is not responsible
7. Always operate the unit with the AC ground wire connected to the
for damage to loudspeakers for any reason.
electrical system ground. Precautions should be taken so that the
means of grounding of a piece of equipment is not defeated. 18. Do not ground any “hot” (red) terminal. Never connect a “hot” (red)
output to ground or to another “hot” (red) output!
8. Mains voltage must be correct and the same as that printed on the
rear of the unit. Damage caused by connection to improper AC voltage 19. Non-use periods: the power cord of equipment should be unplugged
is not covered by any warranty. from the outlet when left unused for a long period of time.
9. Have gain controls on amplifiers turned down during power-up 20. Service Information Equipment should be serviced by qualified service
to prevent speaker damage if there are high signal levels at the inputs. personnel when:
10 Power down and disconnect units from mains voltage before making A. The power supply cord or the plug has been damaged.
connections.
B. Objects have fallen, or liquid has been spilled into the equipment
11. Never hold a power switch in the “ON” position if it won’t stay
there itself! C. The equipment has been exposed to rain

12. Do not use the unit near stoves, heat registers, radiators, or other heat D. The equipment does not appear to operate normally, or exhibits a
producing devices. marked change in performance

E. The equipment has been dropped, or the enclosure damaged.

THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL
INTRODUCTION AND CONTENTS

Building on the reliability and sonic quality of the very popular XR speaker INTRODUCTION 3
series, Australian Monitor brings you the AM Pro XRS two way injection moulded
speaker enclosures with more features and new aesthetic to suit both live FRONT AND REAR PASSIVE PANEL 4
sound reinforcement and permanent installation. From Front of House to fold
back, the dance floor to background fill, the XRS series with both passive and REAR POWERED PANEL 5
powered options are designed with flexibility and performance in mind.

The AM Pro XRS range includes 8”, 10” and 12” models all with high quality SPECIFICATIONS 6
compression drivers and represent a significant advancement in injection
moulded box design while maintaining excellent audio quality and great value
for money.

AUS, EUR, USA


REV A 24th Nov 2008

CAUTION
This symbol is intended to alert the user to the presence of uninsulated
RISK OF ELECTRIC SHOCK
DO NOT OPEN “dangerous voltage” within the products enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,


DO NOT REMOVE COVER (OR BACK), This symbol is intended to alert the user to the presence of important
NO USER SERVICEABLE PARTS INSIDE, operational and maintenance (servicing) instructions in the literature
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. accompanying the appliance.

Caution: To prevent electric shock do not use this (polarised) plug with an extension
cord, receptacle or other outlet unless the blades can be fully inserted to
prevent blade exposure. To prevent electric shock, match wide blade of
WARNING! plug to wide slot, fully insert.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

XRS SERIES INSTALLATION AND OPERATION MANUAL PAGE 3


FRONT AND REAR PANEL PASSIVE VERSION

1 2 1 XRS8 shown here

1 High Frequecy Driver 1 Speaker Input

Horn loaded compression driver. Directivity 90deg x 90deg. The input connector is a 4 pole speakon compatible connector.
Passive crossover in the XRS8/10/12. Pins 1+ and 1- are wired to the +ve and -ve respectively of
XRS8/XRS8P 1.5” the speaker. The XRS10 and XRS12 have 2 connectors. They
XRS10/XRS10P 1.5” are wired in parallel so either connector can be used as an
XRS12/XRS12P 2” input, the other as a loop through.

Active crossover and power amp in XRS8P/10P/12P. Accessories:


XRS8P 50W
XRS10P 50W XRS8/XRS8P
XRS12P 100W XR8PMA Pole mount adapter
XR8UMB Universal mounting bracket

2 Low Frequency Woofer


XRS10/XRS10P
Driver sizes: XR10CVR Heavy duty cover
XRS8/XRS8P 8” AMISLSB1 Wall mount brackets
XRS10/XRS10P 10” ATC303 Tripod speaker stand
XRS12/XRS12P 12” ATC304 Heavy duty tripod speaker stand
ATC305 Winch up speaker stand
Active crossover and power amp in XRS8P/10P/12P. XR10-12UB Universal bracket
XRS8P 100W
XRS10P 100W XRS12/XRS12P
XRS12P 300W XR12CVR Heavy duty cover
AMISLSB1 Wall mount brackets
Note that the XRS8 ships as a pair. ATC303 Tripod speaker stand
ATC304 Heavy duty tripod speaker stand
ATC305 Winch up speaker stand
XR10-12UB Universal bracket

PAGE 4 XRS SERIES INSTALLATION AND OPERATION MANUAL


REAR PANEL POWERED VERSION

7 10 2 8 11 4 9 12 6

1 MIC IN 10 Line LEVEL

This is a balanced XLR microphone input. This controls the level of the LINE input.
(3)
2 Mic SIGNAL
11 Line BASS
This is a green LED signal present
indicator for the Mic input. It indicates This is the bass control for the LINE input
signal present on the input and is not (3). There is 12dB of cut and boost at
affected by the level control. 100Hz. This EQ is the shelving type.

1
3 LINE IN 12 Line TREBLE
3
5 This is a balanced XLR line level input. This is the treble control for the LINE
input (3). There is 10dB of cut and boost
at 10kHz. This EQ is the shelving type.
4 Line SIGNAL

This is a green LED signal present 13 Power Switch


indicator for the Line input. It indicates
signal present on the input and is not This switch turns the power on or off to
affected by the level control. the unit.

5 LINE OUT 14 IEC Mains Input Socket

The LINE OUT is on an XLR connector. This is a standard IEC 3 pin socket.
This output can be connected to the LINE It accepts a standard IEC mains cable,
IN on another XRS Powered speaker to (provided). The fuse draw contains the
expand the system. mains fuse and a spare.

The mains fuse is a time lag (slow blow)


6 Output CLIP HRC 20mm x 5mm ceramic or glass type
fuse.
This is a red LED clip indicator for the
mixed mic and line audio signal. Some XRS8P XRS10P XRS12P
flashing of red is acceptable on program
2.5A 2.5A 5.0A
transients. Continuous flashing of red
could be placing undue stress on the
speaker and will sound distorted. Turn IMPORTANT: Always replace the
down the input level until the clip LED is fuse with one of the same value and type.
no longer lit.
NOTE: Always disconnect power to
7 Mic LEVEL the amplifier before replacing fuses.
15 13 14
This controls the level of the MIC input
15 Voltage Select Switch
(1).
This switch is used to select the mains
8 Mic BASS voltage for your region. Select either
230V or 115V.
This is the bass control for the MIC input
(1). There is 12dB of cut and boost at IMPORTANT: Disconnect power to
100Hz. This EQ is the shelving type. the amplifier before operating this switch.

9 Mic TREBLE IMPORTANT: Make sure this setting


is correct before connecting the unit to
This is the treble control for the MIC input the mains.
(1). There is 10dB of cut and boost at
10kHz. This EQ is the shelving type.

XRS SERIES INSTALLATION AND OPERATION MANUAL PAGE 5


SPECIFICATIONS

XRS8P XRS10P XRS12P

Drivers 1 x 8” woofer 1 x 10” woofer 1 x 12” woofer


1 x 1.5” HF driver 1 x 1.5” HF driver 1 x 2” HF driver

Frequency Response(-3dB) 65Hz-18kHz 55Hz-18kHz 50Hz-18kHz

Frequency Response(-10dB) 55Hz-18kHz 50Hz-18kHz 40Hz-20kHz

Peak Sound Level(dB 1m) 118dB 121dB 125dB

Tone controls
Bass control @ 100Hz 12dB 12dB 12dB
Treble control @ 10kHz 10dB 10dB 10dB

Output Power 100W(low) + 50W(high) 100W(low) + 50W(high) 300W(low) + 100W(high)

Distortion (THD)
Line 0.02% 0.02% 0.02%
Microphone 0.04% 0.04% 0.04%

Tweeter Dispersion(HxV) 90° x 90° 90° x 90° 90° x 90°

Input Impedance
Line 20kOhm 20kOhm 20kOhm
Microphone 10kOhm 10kOhm 10kOhm

Connectors XLR 3 XLR 3 XLR 3

Power Supply AC 115V/230V, 50/60Hz AC 115V/230V, 50/60Hz AC 115/230V, 50/60Hz

Dimensions(WxDxH) 277 x 265 x 407mm 325 x 308 x 478mm 415 x 391 x 600mm

Packing Dimensions(WxDxH) 355 x 325 x 470mm 375 x 355 x 535mm 465 x 435 x 680mm

Net Weight 8.6kg 10.5kg 23kg

Gross Weight 10.1kg 11.8kg 25.2kg

PAGE 6 XRS SERIES INSTALLATION AND OPERATION MANUAL


SPECIFICATIONS

XRS8 XRS10 XRS12

Drivers 1 x 8” woofer 1 x 10” woofer 1 x 12” woofer


1 x 1.5” HF driver 1 x 1.5” HF driver 1 x 2” HF driver

Frequency Response(-3dB) 65Hz-18kHz 55Hz-18kHz 50Hz-18kHz

Frequency Response(-10dB) 60Hz-20kHz 50Hz-20kHz 40Hz-20kHz

Sensitivity(dB 1W 1m) 92 dB 95 dB 97 dB

Impedance 8 Ohm 8 Ohm 8 Ohm

Recommended Max Power(Wrms) 100 W 250 W 300 W

Max Sound Level(dB 1m) 118dB 125dB 128dB

Dispersion(HxV) 90° x 90° 90° x 90° 90° x 90°

Harmonic Distortion 1% 1% 1%

Speakon compatible connectors 1 2 2

Dimensions(WxDxH) 277 x 257 x 400mm 321 x 321 x 464mm 415 x 382 x 620mm

Packing Dimensions(WxDxH) 595 x 310 x 460mm 375 x 355 x 535mm 465 x 435 x 680mm

Net Weight 6.5kg 10kg 18kg

Gross Weight 15kg (pair) 12kg 20kg

XRS SERIES INSTALLATION AND OPERATION MANUAL PAGE 7


AUSTRALIA AND NEW ZEALAND
www.australianmonitor.com.au

SYDNEY MELBOURNE ADELAIDE AUCKLAND


(NSW SALES) (VIC & TAS SALES) (SA & NT SALES) (NZ SALES)

1 Clyde Street 22/277 31 Walsh Street 9C Piermark Drive


Silverwater Middleborough Road Thebarton Albany 0752
NSW 2128 Box Hill VIC 3128 SA 5031 New Zealand
Private Bag 149 PO Box 151 Blackburn PO Box 157 PO Box 300-512
Silverwater NSW 1811 South VIC 3130 Hindmarsh SA 5007 Albany 0752
Phone: (02) 9647 1411 Phone: (03) 9890 7477 Phone: (08) 8352 4444 Phone: (09) 415 9426
Fax: (02) 9648 3698 Fax: (03) 9890 7977 Fax: (08) 8352 4488 Fax: (09) 415 9864
Email: Email: Email: Email:
[email protected] [email protected] [email protected] [email protected]

CANBERRA BRISBANE PERTH


(ACT SALES) (QLD SALES) (WA SALES)

1st Floor, 42 Commercial Road 3/11 Howe Street


Campion Street Fortitude Valley Osborne Park WA 6017
Deakin ACT 2600 QLD 4006 PO Box 1281
PO Box 109 PO Box 2578 Fortitude Osborne Park BC
Deakin West ACT 2600 Valley BC QLD 4006 WA 6916
Phone: (02) 6260 4544 Phone: (07) 3852 1312 Phone: (08) 9204 0200
Fax: (02) 6260 4744 Fax: (07) 3252 1237 Fax: (08) 9244 3783
Email: gordon.anderson@ Email: Email:
hillssvl.com.au [email protected] [email protected]

EUROPE / ASIA / MIDDLE EAST


www.australianmonitor.com.au

INTERNATIONAL SALES
1 Clyde Street Silverwater NSW 2128 Australia
Private Bag 149 Silverwater NSW 1811
Phone: + 61 2 9647 1411
Fax: + 61 2 9748 2537
Email: [email protected]
1 2 3 4 5 6 7 8

IC4
TDA7294

BOOTSTRAP
STBY-GND

STAND-BY
IN-GND

+PWVS

-PWVS
MUTE

OUT
SUR

+VS
IN+

-VS
R4

NC
NC
IN-
IC2C
IC1A 100K IC2D C6 9
2 IC1B C4 13 123 8
1R3 5 C3 123 R10
14 10 -35V +35V

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
3 7 12 15K JP5
10K R11
6 15K C7 TL074 C8 C10
TL072 R7
NP-10uF/25V R8 R9 TL074 392 1U/50V LOW+

1K
15K 15K

22K
47K

R22

R23
TL072 C2 C5
R1 R2 22P 392 474 R24
10K 100K R6 +15V R12 R21 10/1W
CZ03A CZ02A R5 15K 20K
D +15V INPUT+ 100K 10K Q1 D3 D
1 1 R19 R16 R15 R14 R13 C12
2 2
-15V INPUT- 2K2 1M 10K IC2A 10K 47K IC2B C11 22U/50V C13 C14
C1 3 3
1N4148 D2 2 D1 6 22U/50V 104
CZ01 10U/25V-NP XP3 XP3 2N5551 R17 1 7
C9 2.2U/100VJP9
-15V 1M 3 5
1 -15V 1U/50V
GND 1N4148 1N4148 IC5 HIGH A+
2 R18 TL074 TL074
+15V TDA7294
3 +15V

BOOTSTRAP
S-IN 10K
4

STBY-GND

STAND-BY
LIMIT
5 JP6

IN-GND

+PWVS

-PWVS
MUTE
TJC3-5A LOW-

OUT
SUR

+VS
IN+

-VS

NC
NC
IN-
LIMIT

C21 -35V +35V JP8

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
JP7 HIGH-
R28 IC3C HIGH+
CV1 CV3 CV5 R26 IC3D 8K2 9 474

C24 10U/50V
8K213

1K2

22K
R39

R40
104 104 104 C17 C18 8

4
C15 C16 14 10 R45
+15V IC1C IC2E IC3E 12 10/1W

10U/50V
153 153 TL074 R38

V-

V-
V+

V+
153 153 R27
TL074 R29

C25
-15V 6K8 6K8 20K C23
TL072 TL074 TL074 C19 C22 22U/50V C26

11

11
104 22U/50V 104

R43 51K
CV2 CV4 CV6
104 104 104 +15V R30
5K6 R41 D8
Q2 D6 DZ1 5K1 1N4148
R37 R34 R33 R32 R31 R44
C16
R16 RP1-1 RP2-1 CT01A D7 IC3A IC3B
1 1 2K2 1M 10K 10K 47K 10K R42
2

47 6 J2A RP2-3 J1A RP1-3 CT01 -15V LIMIT 1N4148 D5 2 D4 6 1N4007


10U/25V-NP R15 2 2 1 R35 20K
CON3 7 -15V 2N5551 1 7
3 3 5 2 C27
5040 C17 10K 5 IN2 IN1 GND SIN-OUT 1N4148 1M 3 5
R17 IC2B 4 4 4 3 R20 C20 10U/50V
3 +15V +15V 1N4148 1N4148
5 5 3 4 1M 104 R36 TL074 TL074
47 C15 JRC4560 SIN-OUT GND
10U/25V-NP 22P R14 6 6 2 5
2 RP1-3 LIMIT -15V 10K
7 7 1 6
C 1 10K C
8 -15V 8 -15V
3 5P*100MM(2.5MM) 6P*100MM(2.5MM)
1

IC2A R13 9 9
RP2-3
10 +15V 10 +15V
JRC4560 10K
10PIN2.54mm 10PIN2.54mm
+15V D1
C1
10U/25V-NP 1N4148 R3
R1 30K
1N4148

CON1 560 C5
5044 22P
D2

IC1B
6 C7 C18 IC3A
2 1 C2 -15V 7 RP2-1 10U/25V-NP IC3B 3 JRC4560
47P +15V 5 IN1 R18 5 1 SIN-OUT
C20
10U/25V-NP R21
1N4148

7 2
IN2 R19 10K 6 LIMIT
C3 JRC4560 10K C22
D3

JRC4560
3

R2 10K
C19 C21 10U/25V-NP JP4
10U/25V-NP 22P R22
560 OPT1 22P
10U/25V-NP R4 R11 R20
+15V LCR0202
10K
D4 C6 30K R46
1K5 10K Earth
1N4148 22P R28 LED1 JP1 +35V
440 IC6
-15V 150K GREE 7815 +15V

2
1 3

GND
R5 Vin Vout CV23 CV25 CV29
Q3 ~28V CV27 CV31
CV17 CV19 CV21 JP3 6800U/50V 470U/50V 470U/50V
5K1 BR1 104 104

AC

V+
+15V D5 C4 D9 1000U/35V 220U/25V 104
C8 2N5551 KBU-806
10U/25V-NP 1N4148 R9 473 IN4148 R27

2
R7 30K R26

AC
GND

V-
100K

1
Q1
1N4148

CON2 10K C12 -15V 100 CV28 CV32


22P R25 JP2 CV24 CV26 CV30
5044 104 104
CV18 CV20 6800U/50V 470U/50V 470U/50V
D6

C14 Q2 CV22

4
R24 3K3

GND
IC1A 1000U/35V 220U/25V 104
2 CV5 CV3 +15V
CV1 2N5551 2 3
Vin Vout
8

2 1 -15V 1 RP1-1 104 104 104 ~28V -35V


2K2
C9 +15V 3 IC3C IC2C IC1C LED3 2N5401 R23 IC7 -15V
10U/25V-NP 100K R47 7915
1N4148

47P RED
CV8
C10 JRC4560 440
JRC4560 100U/50V
D7

10U/25V-NP JRC4560 JRC4560


3

R8
4

R12 CV6 CV4 CV2-15V +15V


B 10K +15V B
R10 LED2 104 104 104
1K5
D8 30K C13 R29 GREE
1N4148 22P 150K
-15V
R6 Q4
5K1
C11 D10 2N5551
473 IN4148

RP3
R5 R6
B50K

R3 R4 7K5 TREBLE 7K5


10K 15K R9
C1 IC4A C3 1M
JRC4560 472
J1
RP1-1 2 22P R10 C6
1
RP1-1

RP1-3

RP1-3 1 10K 22P


2
3 6
3
OUT1 RP1 C4 C5 7
4 R1
10K 103 103 5
5
6 R7 R8 IC4B
7 R2
8 -15V 15K RP2 15K JRC4560
A50K 15K
9 B50K BASS
10 +15V
10PIN2.54mm

A CV7 A
8

104
IC4C +15V
JRC4560

-15V
4

CV8
104

Australian Monitor
XRS10P

1 2 3 4 5 6 7 8

You might also like