ST-1_101425
ST-1_101425
2.02
ELEV.
WF-2
+0.20MTS. ELEV.
+0.20MTS. MUNICIPALITY OF SAN ISIDRO
1.03 1.03
+0.20MTS.
C1F1 WF-2 2 - 16mm.Ø 2 - 16mm.Ø 10mm.Ø rsb
DISTRICT/CITY/MUNICIPALITY
WF-1 ON FILL spaced @ 5 - 50mm.,
WF-1
B-2 2 - 16mm.Ø
2.10
2 - 12mm.Ø
STAIR WF-2 ELEV. 2 - 12mm.Ø 2 - 16mm.Ø 150mm. x 300mm. 5 - 100mm., 5 - 150mm.,
5.97
5.82
WELL +0.20MTS. 2 - 16mm.Ø 2 - 16mm.Ø and rest @ 200mm. o.c.
WF-2
WF-2 ON FILL
2.90
ELEV.
+0.20MTS.
C1F1 C1F1 3 - 16mm.Ø 3 - 16mm.Ø 10mm.Ø rsb
spaced @ 5 - 50mm.,
2.29
ON FILL
WF-1
0.90
3 - 16mm.Ø 3 - 16mm.Ø
C1F1 C4F3
WF-2 WF-2
C2F2 WF-2 C2F2 3 - 20mm.Ø 3 - 20mm.Ø 10mm.Ø rsb LINE AND GRADE
spaced @ 5 - 50mm.,
1.20 1.00 TB 250mm. x 350mm. 5 - 100mm., 5 - 150mm.,
ON FILL 3 - 20mm.Ø 3 - 20mm.Ø and rest @ 200mm. o.c.
ELEV. 0.98 0.70
1.55 1.000.55 1.20 0.461.18 1.20 1.18
3.81
WF-1
+0.15MTS.
WF-2
C3F2 C3F2
COLUMN AND
FOOTING
FIN FLR. LINE CL 100 mm THK CONC SLAB
0.20
LAND USE & ZONING
RC COLUMN 100 MM GRAVEL W/ 10 mm Ø TEMP BARS
@ 500 mm O/C BW
3.81
( see schedule)
FFL
WF-2
WF-1
0.30
1.00
15.25
VARIES
FGL 6 - 12MM Ø BASEBARS
C3F2 C3F2 # 5'' CHB SET ON BOTHWAYS
FILL 10 mm Ø HOR BARS ARCHITECTURAL
3.81
N.G.L.
WF-1
FILL
10 mm. Ø TIES SPACED
@4 @ 100mm
4 @ 150mm
REST @ 200mm
NGL
D
0.83 350
600
TIE SPACING SEE W/ 10MM Ø TIES
WF-2
3 - 10 mm Ø CONT
3.81
COL DETAILS
LONGITUDINAL BARS 6- 12MM Ø BASEBARS
STRUCTURAL
WF-1
1.00
SET ON BOTHWAYS
FOOTING REINF
SEE SCHEDULE
C3F2
100 MM GRAVEL BED
100 MM GRAVEL BED
SECTION
0.30
LENGTH
(see schedule)
SECTION 0.40
C3F2 ELEVATION / SECTION
75MM CONC COVER
C2F2
5.50
TYPICAL COL./FTG. & WALL FTG. DETAIL 1.00
SCALE 1:100
0.30
1.00
6 - 12MM Ø REBARS
W/ 10MM Ø TIES
'A' = COL STRIP 0.25 X 'A' MIDDLE STRIP 0.13 X 'B' 'B' = COL STRIP 0.13 X 'B' 5" THK. CHB 4" THK. CHB
6 - 12MM Ø BASEBARS
SET ON BOTHWAYS
10MMØ HORIZONTAL 10MMØ HORIZONTAL
0.25 L1 0.25 L1 0.25 L2 BARS SPACED @ EVERY
3 LAYERS OF CHB
BARS SPACED @ EVERY
3 LAYERS OF CHB PLAN
25mm CLEAR TOP BARS 10MMØ VERTICAL BARS 10MMØ VERTICAL BARS
N.G.L. SPACED @ 0.70 to 0.80 M.O.C. N.G.L. SPACED @ 0.70 to 0.80 M.O.C. 10 mm. Ø TIES SPACED
@4 @ 100mm
4 @ 150mm
REST @ 200mm
ELECTRICAL
T
0.50
STD 180° HOOKS
EXCEPT STD °90
PLACE ALL COL STRIP REINFORCING WITHIN COL STRIP 6 - 12MM Ø REBARS
0.20
0.20
1.00
@ 0.25 M.O.C. @ 0.25 M.O.C. SET ON BOTHWAYS
0.40 0.30
0.30
WF - 1 WF - 2
C3F2
SCALE NTS
MECHANICAL
Article 2 Section 25 (4)
SEALED: CIVIL ENGINEER: REVISIONS: DATE: PROJECT TITLE: OWNER: R.A. 9266 SHEET CONTENTS: SHEET NO:
Drawings and specifications duly signed, stamped or sealed as instruments of
service are the properties and documents of the architect whether the object for which
PROPOSED (3) STOREY RESIDENTIAL BUILDING REMSON, RAMAYRAT, REYES they are made is executed or not. It shall be unlawful for any person, without the
DATE ISSUED: 829 BAGUISA STREET, BARANGAY MALAPIT,SAN ISIDRO, NUEVA ECIJA DATE APPROVED:
MALAPIT,SAN ISIDRO, NUEVA ECIJA PRESIDENTIAL DECREE NO. 49
"Protection of Intellectual Property" November 14, 1972
Works of art, architecture, models and designs are creative work and considered
6 14
considered as part of the inllectual property of the author duly protected under P.D. 49.
TIN: PLACE ISSUED: