Neu 2140 GK
Neu 2140 GK
Code: 958JA51
APPLICATION
Evaporating temperature range: -40 to -10 ºC Cooling type: Fan Cooling
Permanent operating temperature (peak) : 55 (60) ºC Air Flow --
Expansion device: Capillary tube or Expansion valve Maximum motor temperature: 130 ºC
ELECTRICAL DATA
Start winding resistance at 25°C (77°F): 24.26 Ω +/- 8% Run winding resistance at 25°C (77°F): 7.79 Ω +/- 8%
FLA - full load amperage L/MBP [A] 50 Hz / 60 Hz: 2.63 / - LRA (A) 50 Hz / 60 Hz: 13.5 / -
FLA - full load amperage HBP [A] 50 Hz / 60 Hz: -/-
MECHANICAL DATA
Bore: 26.5 mm Stroke: 7.96 mm
Displacement: 8.77 cm³
OTHER INFORMATION
Weight: 10.6 kg Oil charge: 350 ml
Lubricant type: Polyolester ISO22 Nitrogen charge: No
EXTERNAL SETTINGS
- Shape Material Diameter [mm]
Suction connector Slanted 42° Copper 8.10
Discharge connector Straight Copper 6.10
Process connector Slanted 42° Copper 6.10
Base plate: European Standard Tray holder: No
PERFORMANCES AT STANDARD CHECK-POINTS
Cooling capacity Power consumption Gas flow rate Cooling Efficiency Heating capacity +/- Heating Efficiency
Checkpoint +/-5% +/-5% +/-5% +/- 7% 5% * +/- 7%
W W kg/h W/W W W/W
ARI LBP 352.69 386.67 12.45 0.91 525.24 1.36
ASHRAE LBP
467.88 362.37 10.87 1.29 648.77 1.79
32
CECOMAF 317.89 345.36 9.90 0.92 489.59 1.42
LBP
EN12900 260.28 251.39 6.53 1.04 380.30 1.51
LBP**
EN12900
MBP** 791.33 467.27 21.73 1.69 1,026.12 2.20
* Calculations performed considering isentropic compression and a housing loss of 10%. This is an estimated heat amount discarded in the
discharge pipe and the condenser combined.
ELECTRICAL ACCESSORIES
Kit: 1 Thermal protector: MST38AMK-3259
Starter device: CURRENT RELAY Institutes approved for this electric kit:
Engineering code: MTRPH-0025-65
Run capacitor: --
Starting capacitor: 64-77
If purchased without electricals consult Embraco to verify the supplier of electricals approved for this compressor
MECHANICAL ACCESSORIES
Rubber damper: Yes Metal bushing: Optional
D
E
A
C
ECM REVISION LO BY APP DATE
33471 25 A D D E D N E W M O D E L N E U 6T2A1B4 Z L F MG 11.04.2014
33788 26 A D D E D N E W M O D E L N E U 6T2A1B4 U L K MG 07.05.2014
34098 27 A D D E D M O D E L S N E U 2 1 4 0 G K T, AN BE U 2L1F5 5 G MK G 02.06.2014
ADDED MODELS NEU6210Z,NEU6212Z,
(COPPER THICK 1)
PROCESS"C"
32548 28 N E U 2 1 6 8 G J , N E U 6 2 1 0 TU A B M R LF 22.9.2014
ADDED "NEU" TO DRW DESCRIPTION
A D D E D N O T E : C S I R , R S I R , R SEC6R T O P G . 1 ;
A D D E D P A G E 2 - C S R C O N F I G U-R-A T I O N ;
M O D E L S N E K 2 1 7 2 G K , N E K 6 2 T1 A7 BG K ,
16 +0,25
37454 29 NEU2178GK, NEU2168GJ MOVED KK RR 11.03.2015
6
6
FROM PG.1 TO PG.2;
C H A N G E P O S I T I O N O F R E F R I DG 4E R A N T
0
LABEL - PG.3;
35759 30 A D D E D M O D E L N E U 6 1 8 7T ZA B KP MG 10.06.2015
(6 HOLES)
ADDED SHELL TYPE 810.32
38932 31 TAB MG RR 12.01.2016
AND MODEL NBT1112Y
ADDED MODELS NEU6220U,
N E U 6 2 1 2 U , N E U 6 2 2 0 G KT;A B
37531 32 PS MG 05.10.2016
MODEL TABLES MOVED TO SHHET 3;
SHEET 3 REWORKED;
CHANGED DIMENSION KK
42
44703 33 F R O M 2 0 1 T O 2 0 0 m m AT NA DB
FROM 207 TO 206 mm;
KK MG 05.01.2017
($2
X)
6.3
5
5
142
100 3
88
70 3 (2X)
193 1,5
199 1,5
178 0,5
170
100 3
4
4
127 3
Z
51 13 3 (2X)
70
22 3
APP.:
DRAWN :
MATERIAL :
ECM :
CODE :
38.5
K#2.5
503723
MARTINKO J.
TONELLA M.
KK#2.5
3
REQUIRED BY B.O.M.
START CAPACITOR IF
(COPPER THICK 1)
SUCTION "B"
(NE/NEKxxxxR)
ARE USED BOTH
RECOVERY COMPRESSORS
FOR REFRIGERANT
OR 2.216.507TAB.
DRAWINGS 2.216.283TAB
LABELS ACCORDING TO
PLACE FOR REFRIGERANT
(COPPER THICK 1)
DISCHARGE "A"
16 MIN. (3 TUBES)
NOT PAINTED
06-10-2003
SCALE
2
WITHOUT WRITTEN PERMISSION.
1:5
156 1,5
162 1,5
SHEET 1/3
ANG. TOL. :
No.
GEN. TOL. :
SCALE :
REPLACE
1
1.960.853
1:2
X
B
A
E
D
D
E
A
C
ECM REVISION LO BY APP DATE
33471 25 A D D E D N E W M O D E L N E U 6T2A1B4 Z L F MG 11.04.2014
33788 26 A D D E D N E W M O D E L N E U 6T2A1B4 U L K MG 07.05.2014
34098 27 A D D E D M O D E L S N E U 2 1 4 0 G K T, AN BE U 2L1F5 5 G MK G 02.06.2014
ADDED MODELS NEU6210Z,NEU6212Z,
(COPPER THICK 1)
PROCESS"C"
32548 28 N E U 2 1 6 8 G J , N E U 6 2 1 0 TU A B M R LF 22.9.2014
ADDED "NEU" TO DRW DESCRIPTION
A D D E D N O T E : C S I R , R S I R , R SEC6R T O P G . 1 ;
A D D E D P A G E 2 - C S R C O N F I G U-R-A T I O N ;
M O D E L S N E K 2 1 7 2 G K , N E K 6 2 T1 A7 BG K ,
16 +0,25
37454 29 NEU2178GK, NEU2168GJ MOVED KK RR 11.03.2015
6
6
FROM PG.1 TO PG.2;
C H A N G E P O S I T I O N O F R E F R I DG 4E R A N T
0
LABEL - PG.3;
35759 30 A D D E D M O D E L N E U 6 1 8 7T ZA B KP MG 10.06.2015
(6 HOLES)
ADDED SHELL TYPE 810.32
38932 31 TAB MG RR 12.01.2016
AND MODEL NBT1112Y
ADDED MODELS NEU6220U,
N E U 6 2 1 2 U , N E U 6 2 2 0 G KT;A B
37531 32 PS MG 05.10.2016
MODEL TABLES MOVED TO SHHET 3;
SHEET 3 REWORKED;
CHANGED DIMENSION KK
42
44703 33 F R O M 2 0 1 T O 2 0 0 m m AT NA DB
FROM 207 TO 206 mm;
KK MG 05.01.2017
($2
X)
6.3
5
5
142
100 3
88
70 3 (2X)
193 1,5
199 1,5
178 0,5
170
100 3
4
4
127 3
Z
51 13 3 (2X)
70
22 3
APP.:
DRAWN :
MATERIAL :
ECM :
CODE :
38.5
K#2.5
503723
MARTINKO J.
TONELLA M.
KK#2.5
3
REQUIRED BY B.O.M.
START CAPACITOR IF
(COPPER THICK 1)
SUCTION "B"
(NE/NEKxxxxR)
ARE USED BOTH
RECOVERY COMPRESSORS
FOR REFRIGERANT
OR 2.216.507TAB.
DRAWINGS 2.216.283TAB
LABELS ACCORDING TO
PLACE FOR REFRIGERANT
(COPPER THICK 1)
DISCHARGE "A"
16 MIN. (3 TUBES)
NOT PAINTED
06-10-2003
SCALE
2
WITHOUT WRITTEN PERMISSION.
1:5
156 1,5
162 1,5
SHEET 1/3
ANG. TOL. :
No.
GEN. TOL. :
SCALE :
REPLACE
1
1.960.853
1:2
X
B
A
E
D
D
E
A
C
ECM REVISION LO BY APP DATE
33471 25 A D D E D N E W M O D E L N E U 6T2A1B4 Z L F MG 11.04.2014
33788 26 A D D E D N E W M O D E L N E U 6T2A1B4 U L K MG 07.05.2014
34098 27 A D D E D M O D E L S N E U 2 1 4 0 G K T, AN BE U 2L1F5 5 G MK G 02.06.2014
ADDED MODELS NEU6210Z,NEU6212Z,
(COPPER THICK 1)
PROCESS"C"
32548 28 N E U 2 1 6 8 G J , N E U 6 2 1 0 TU A B M R LF 22.9.2014
ADDED "NEU" TO DRW DESCRIPTION
A D D E D N O T E : C S I R , R S I R , R SEC6R T O P G . 1 ;
A D D E D P A G E 2 - C S R C O N F I G U-R-A T I O N ;
M O D E L S N E K 2 1 7 2 G K , N E K 6 2 T1 A7 BG K ,
16 +0,25
37454 29 NEU2178GK, NEU2168GJ MOVED KK RR 11.03.2015
6
6
FROM PG.1 TO PG.2;
C H A N G E P O S I T I O N O F R E F R I DG 4E R A N T
0
LABEL - PG.3;
35759 30 A D D E D M O D E L N E U 6 1 8 7T ZA B KP MG 10.06.2015
(6 HOLES)
ADDED SHELL TYPE 810.32
38932 31 TAB MG RR 12.01.2016
AND MODEL NBT1112Y
ADDED MODELS NEU6220U,
N E U 6 2 1 2 U , N E U 6 2 2 0 G KT;A B
37531 32 PS MG 05.10.2016
MODEL TABLES MOVED TO SHHET 3;
SHEET 3 REWORKED;
CHANGED DIMENSION KK
42
44703 33 F R O M 2 0 1 T O 2 0 0 m m AT NA DB
FROM 207 TO 206 mm;
KK MG 05.01.2017
($2
X)
6.3
5
5
142
100 3
88
70 3 (2X)
193 1,5
199 1,5
178 0,5
170
100 3
4
4
127 3
Z
51 13 3 (2X)
70
22 3
APP.:
DRAWN :
MATERIAL :
ECM :
CODE :
38.5
K#2.5
503723
MARTINKO J.
TONELLA M.
KK#2.5
3
REQUIRED BY B.O.M.
START CAPACITOR IF
(COPPER THICK 1)
SUCTION "B"
(NE/NEKxxxxR)
ARE USED BOTH
RECOVERY COMPRESSORS
FOR REFRIGERANT
OR 2.216.507TAB.
DRAWINGS 2.216.283TAB
LABELS ACCORDING TO
PLACE FOR REFRIGERANT
(COPPER THICK 1)
DISCHARGE "A"
16 MIN. (3 TUBES)
NOT PAINTED
06-10-2003
SCALE
2
WITHOUT WRITTEN PERMISSION.
1:5
156 1,5
162 1,5
SHEET 1/3
ANG. TOL. :
No.
GEN. TOL. :
SCALE :
REPLACE
1
1.960.853
1:2
X
B
A
E
D