SFD 100
SFD 100
SFD200
Can be disassembled.
(Cartridge type)
Replaceable hollow fibre elements
Made to Order
Stainless steel or
aluminum cases are available.
Metal case that is suitable for an atmosphere
exposed to organic solvents and chemicals.
(Fluids: Air and (Nitrogen))
Made to Order
Features 1
Integrated production in a clean environment
Under a clean environment, all components have undergone ultrasonic cleaning.
Assembly, inspection and antistatic double packaging processes are conducted in an integrated production system.
쎲 Quality Control 쎲
At the time of shipment, the SFD series clean air filter is 100% inspected.
Application Examples
Protection of
Clean blow precision equipment
• Substitution of
chamber
• Fluid pumping,
etc.
∗ When blowing, take care not to entrain ambient air
which could contaminate the workpieces.
Circuit Examples
Heatless
air dryer or
Refrigerated Membrane Super mist Fluid Clean blow
Air source After-cooler air dryer air dryer separator
Paint
– +
∗ The equipment mounted to the secondary side of the SFD unit should be cleaned
by flushing and have the same level of cleanliness as the SFD unit.
Filter
Features 2
Series SFD
Model Selection
Select the model by using the following procedures involving the inlet pressure and the maximum flow rate.
[Example] Inlet pressure: 0.6 MPa
Maximum flow rate: 100 l/min (ANR)
1. Obtain the intersection A for the inlet pressure and the maximum flow rate by using the maximum flow rate chart.
2. If the obtained intersection A is above the maximum flow rate line, the SFD200-C12, -쏔02, -C10, or -C08 can be selected.
Note) Please be sure to select a model which is above the obtained intersection A. If the obtained intersection A is below the maximum flow rate line, overflow will
occur. This will cause nonconformance in which the specification will not be satisfied.
1000
SFD200-C12, -쏔02
SFD200-C08
SFD200-C10
Flow rate (l/min)
SFD100-C08, -쏔02
A
100
SFD100-04
SFD100-06
10
0 0.5 1
Pressure (MPa)
Front matter 1
Clean Air Filter
Series SFD
How to Order
SFD 1 0 0 C08
Clean air filter
Size
Option
Symbol Max. flow rate
Symbol Option
1 100 l/min (ANR)
- None
2 500 l/min (ANR)
B Bracket (SFD100 only)
∗ The brackets are provided with the SFD200
Case material series as standard. (-)
Symbol Material
0 Resin Port size
1 Aluminum Symbol Connection size Note
2 Stainless steel C04 ø4
SFD100 only
C06 ø6
Symbol 1 and 2 are made to order. Clean one-touch
C08 ø8 fitting (KP series) SFD100/200
For details, refer to page 5.
C10 ø10
SFD200 only
C12 ø12
02 Rc 1/4
Female thread
N02 NPT 1/4
SFD100/200
F02 G 1/4
1
Series SFD
Flow Characteristics
SFD100-C04 SFD200-C08
0.04 0.04
0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa 0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa
Pressure drop (MPa)
0.02 0.02
0 0.00
0 20 40 60 0 100 200 300 400
SFD100-C06 SFD200-C10
0.04 0.04
0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa 0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa
Pressure drop (MPa)
0.03 0.03
Max. flow rate line Max. flow rate line
0.02 0.02
0.01 0.01
0 0
0 20 40 60 80 100 0 100 200 300 400 500
0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa 0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa
Pressure drop (MPa)
0.03 0.03
Max. flow rate line Max. flow rate line
0.02 0.02
0.9 MPa
0.9 MPa
0.01 0.01
0 0
0 20 40 60 80 100 120 0 100 200 300 400 500 600
2
Clean Air Filter Series SFD
Construction
SFD100-C쏔 Component Parts
No. Description Material Note
tyui r q w Element
1 Case: Clear resin
2 Cover Resin
3 Bracket Resin
4 O-ring Rubber
5 Seal Rubber
6 Cushion Rubber
7 Stopper Stainless steel alloy
8 Cassette Stainless steel alloy
e Replacement Parts
No. Description Part no. Note
With 2 countersunk
1 Bracket set SFD-BR100
SFD100-쏔02 head screws (M3)
r q w Component Parts
No. Description Material Note
1 Element Case: Clear resin
2 Cover Resin
3 Bracket Resin
4 O-ring Rubber
Replacement Parts
No. Description Part no. Note
With 2 countersunk
1 Bracket set SFD-BR100 head screws (M3)
e
Component Parts
SFD200-C쏔 No. Description Material Note
1 Element Case: Clear resin
2 Cover Aluminum alloy
r t yu o q !1 w e !2 !4 3 Fitting body Resin
4 Seal Rubber
5 Cushion Rubber
6 Stopper Stainless steel alloy
7 Cassette Stainless steel alloy
8 Bracket Stainless steel alloy
9 O-ring A Rubber
10 O-ring B Rubber
11 Rod cover Stainless steel alloy
12 Tie-rod Stainless steel alloy
i !0 !3 13 Cap nut General type steel Nickel plated
14 Plain washer General type steel Nickel plated
Replacement Parts
No. Description Part no. Note
1 Element set SFD-EL200 With 3 O-rings
Component Parts
SFD200-쏔02 No. Description Material Note
1 Element Case: Clear resin
t q u w e !0 i 2 Cover Aluminum alloy
3 Fitting body Stainless steel alloy
4 Bracket Stainless steel alloy
5 O-ring A Rubber
6 O-ring B Rubber
7 Rod cover Stainless steel alloy
8 Tie-rod Stainless steel alloy
9 Cap nut General type steel Nickel plated
10 Plain washer General type steel Nickel plated
Replacement Parts
r y o
No. Description Part no. Note
1 Element set SFD-EL200 With 3 O-rings
3
Series SFD
Dimensions
SFD100-C쏔 SFD100-C쏔 Dimensions
Model A B
ø2 C04 4 83
3
SFD100- C06 6 83
C08 8 84
SMC
26
23
15
17 51
72 Bracket mounting dimensions
27
Applicable tubing O.D. øA B 42
16
SFD100-쏔02
ø2
3
90°
1.5
3
17 51
∗ Use a countersunk head screw
27 72 (M3) for bracket mounting.
ø3.5
4x7
Applicable tubing O.D. øA B
28
SFD200-쏔02
103.5
SMC
42
24
19 96.5
36 114.5
4
Series SFD
Made to Order 1
Contact SMC for detailed specifications, delivery and prices.
1 Metal Case
Metal case that is suitable for an
Construction
SFD101-02 SFD102-02
q e r w q e r t w
Dimensions
SFD101-02 SFD102-02
66 25 66 25
19 19
ø2 ø2
4 4
50
40
50
40
5
Series SFD
Made to Order 2
Contact SMC for detailed specifications, delivery and prices.
C06
IN port size
C10
C08 — 쏹 쏹 쏹 쏹 C12 — 쏹 쏹 쏹 쏹
02 쏹 쏹 쏹 — — 02 쏹 쏹 쏹 — —
Construction
N02 쏹 쏹 쏹 — — N02 쏹 쏹 쏹 — — The construction and materials are the same as
F02 쏹 쏹 쏹 — — F02 쏹 쏹 쏹 — — the standard product.
∗ The symbol “—” stands for unavailable combination. ∗ The symbol “—” stands for unavailable combination. Refer to “Construction” on page 3.
Dimensions
SFD100 different diameters SFD200 different diameters
One-touch
One-touch fitting
fitting dimensions
dimensions Port size q Port size w
Port size q Port size w
ø4 ø8
5.5 SMC 6.5
ø8 ø12
6 6.5
Model Port size q Port size w Total length Model Port size q Port size w Total length
C04 (C06) C06 (C04) 83 (A + 72 + B) C08 (C10) C10 (C08) 127.5 (A + 114.5 + B)
C04 (쏔02) 쏔02 (C04) 77.5 (72 + A) C08 (쏔02) 쏔02 (C08) 121 (114.5 + A)
SFD100- C06 (C08) C08 (C06) 83.5 (A + 72 + B) SFD200- C10 (C12) C12 (C10) 127.5 (A + 114.5 + B)
C06 (쏔02) 쏔02 (C06) 77.5 (72 + A) C10 (쏔02) 쏔02 (C10) 121 (114.5 + A)
C08 (쏔02) 쏔02 (C08) 78 (72 + A) C12 (쏔02) 쏔02 (C12) 121 (114.5 + A)
6
Related Products
< Pre-filters for Series SFD >
For details, refer to SMC's “Best Pneumatics” catalogue.
7
Related Products
Ionizer Series IZS31
Controlled ion balance by sensor Ionizer model IZS31-쏔쏔 (NPN spec.) IZS31-쏔쏔P (PNP spec.)
쎲 Rapid elimination of static electri- Ion generation method Corona discharge type
city by a feedback sensor Method of applying voltage Sensing DC, Pulse DC, DC
쎲 Ion balance control by an autoba- Output for emitting electricity ±7000 V
Ion balance Note 1) ±30 V (in the case of stainless steel electrode needle ±100 V)
lance sensor
Fluid Air (clean and dry)
Air purge Operating pressure 0.7 MPa or less
Connecting tubing O.D. ø4
Electrode needle material Tungsten, Silicon, Stainless steel
Note 1) For the case where air purge is performed between a charged object and an ionizer at a distance of 300 mm.
Ionizer Note 2) When measuring the potential of a charged object with a feedback sensor, the relationship between
measured charge potential and sensor monitor output voltage and the sensor detecting range will differ
according to the sensor installation distance.
Disposable Type
Main material Thread Port size
Series SFC Series Type
Element Housing Seal type 1/4 3/8
PTFE
SFB300 Straight + Stainless — Rc (PT)
PFA steel 316
TSJ
PTFE (Electro- O-ring
Multiple + URJ
SFC100 polishing) PTFE
disc PVDF
8
Series SFD
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These
instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To
ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices.
쐽Explanation of the Labels
Labels Explanation of the labels
Danger In extreme conditions, there is a possible result of serious injury or loss of life.
Caution Operator error could result in injury Note 3) or equipment damage. Note 4)
Note 1) ISO 4414: Pneumatic fluid power – General rules relating to systems
Note 2) JIS B 8370: General Rules for Pneumatic Equipment
Note 3) Injury indicates light wounds, burns and electrical shocks that do not require hospitalisation or hospital visits for long-term medical treatment.
Note 4) Equipment damage refers to extensive damage to the equipment and surrounding devices.
쐽Selection/Handling/Applications
1. The compatibility of the pneumatic equipment is the responsibility of the person who designs the
pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system
must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and
safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should
continuously review the suitability of all items specified, referring to the latest catalogue information with a view to giving due
consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery and equipment.
Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of the systems using pneumatic equipment
should be performed by trained and experienced operators. (Understanding JIS B 8370 General Rules for Pneumatic Equipment,
and other safety rules are included.)
3. Do not service machinery/equipment or attempt to remove components until safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway
of the driven objects have been confirmed.
2. When equipment is removed, confirm the safety process as mentioned above. Turn off the supply pressure for this equipment
and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity).
3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc.
4. If the equipment will be used in the following conditions or environment, please contact SMC first and
be sure to take all necessary safety precautions.
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and
beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, requiring special safety analysis.
4. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for
the prevention of a breakdown. And, examine the devices periodically if they function normally or not.
Back page 1
Series SFD
Specific Product Precautions 1
Be sure to read this before handling. Refer to the back of page 1 for Safety Instructions
and “Precautions for Handling Pneumatic Devices (M-03-E3A) for Common Precautions.
Warning Warning
1. Thoroughly and carefully confirm the purpose 1. The material of the element is polycarbonate.
of use, required specifications and operating The material is resistant to wiping with alcohol, but is not
conditions (fluid, pressure, flow rate, nominal suitable for atmospheres or places with organic solvents,
chemicals, cutting oils, synthetic oils, ester base compressor
filtration rating and environment) then select oils, alkalis or thread locking agents.
a model within the specifications.
2. The product is not certified under the High Caution
Pressure Gas Safety law, so for nitrogen, its
maximum operating pressure will be 0.99 1. If the pressure difference (pressure drop)
MPa (gauge pressure). between the inlet and the outlet exceeds 0.1
MPa, it can cause damage to the product.
3. Contact SMC beforehand if the product will
be used in an application such as a caisson 2. Do not install the product in a place where it
shield, breathing, food and/or medical treat- can be affected by a pulsation (including
ment that affects the human body directly or surge pressure) of over 0.1 MPa.
indirectly. 3. Use caution regarding the particles that may
4. If the compressed air includes ozone, do not be emitted from the outlet side of pneumatic
use it since it may damage the product or equipment.
Installation of pneumatic equipment on the outlet side can
cause malfunction. When it includes ozone, deteriorate the cleanliness because a particle will be gener-
use a clean gas filter (SFA/B/C). ated from the equipment.
The mounting position of the pneumatic equipment needs to
Mounting be considered.
4. Set the air flow capacity with an initial pres-
Warning sure drop of 0.03 MPa or less. If the initial
1. Instruction manual pressure drop is set to be high, its service
Mount the product after reading and understanding the life will be shorten due to clogging.
instruction manual. Keep it in a location where it can easily be 5. Determine the product by the maximum con-
found. sumption flow rate.
2. Flushing When using compressed air for an air blow application, calcu-
Flush the piping line when the filter is used for the first time or late the maximum volume of air that will be consumed before
has been replaced. In the event of connecting such as piping, selecting the SFD series product size.
flush (air blow) when using this product for the first time or 6.Generally, the following pollutant particles
replacing its elements in order to reduce the affect of the dust
generated from the connection, etc. Flushing the line is also are contained in compressed air.
required to eliminate contamination resulting from the piping [Pollutant particle substances contained in the
line installation. Therefore, be sure to flush the line before compressed air]
actually running the system. Fix all mounting parts for use. • Moisture (drainage)
• Dusts and particles which are in the surrounding air
3.Use fittings with resin threads for the con- • Deteriorated oil which is discharged from the compressor
nection of fittings to the IN and OUT ports. • Solid foreign matter such as rust and/or oil in the piping
Using fittings with metal threads could damage the IN and
1) The SFD series is not compatible with compressed air
OUT ports.
which contains fluids such as water and/or oil.
4. Connect tubing to the IN and OUT one-touch 2) Install a dryer (IDFA, IDG series), mist separator (AM
fittings in accordance with the precautions series), micro mist separator (AMD series), super mist
for one-touch fittings. separator (AME series), or odour removal filter (AMF
series), etc., for the source of the air for the SFD series.
Caution Warning
1. Unpacking the sealed package 1. Do not operate under the conditions listed
Since the filter is sealed in an antistatic double bag, the inner below due to a risk of malfunction.
package should be unpacked in a clean atmosphere (such as In locations having corrosive gases, organic solvents, and
a clean room). chemical solutions, or in locations in which these elements are
2. Apply a wrench to the 2 chamfered flats or likely to adhere to the equipment.
In locations in which salt water, water, or water vapour could
hexagon portion on the IN side or the OUT come in contact with the equipment.
side to prevent the housing from rotating. In locations that are exposed to direct sunlight. (Shield the
3. Always tighten threads with the proper tigh- equipment from sunlight to prevent its resin material from
ultraviolet ray degradation or overheating.)
tening torque. In locations that have a heat source and poor ventilation.
When attaching fittings to the product, tighten with the proper (Shield the equipment from heat sources to protect it from
tightening torque shown below. softening degradation due to radiated heat.)
In locations that are exposed to shocks and vibrations.
Material Tightening torque (N ·m) In locations with high humidity or a large amounts of dust.
Resin 2 to 3
Metal 12 to 14
2. When the product is used for blowing, use
caution to prevent the work from being
4. Check the arrow mark on the case which damaged by entrained air from the
shows the flow direction to connect the IN surrounding area.
When the compressed air is used for air blow, the exhausted
and OUT ports correctly. air from the blow nozzle may have taken in airborne foreign
If connected in reverse, the element could break. matter (such as solid particle, fluid particle) from the
surrounding air. The foreign matter will be sprayed onto the
work, and the airborne foreign matter may adhere to it.
Maintenance Therefore, use caution for the surrounding environment.
Back page 3
EUROPEAN SUBSIDIARIES:
© DiskArt™ 1988
UK
SMC Industrial Automation CZ s.r.o. SMC Pneumatics (Ireland) Ltd. SMC Romania srl SMC Pneumatics (UK) Ltd
Hudcova 78a, CZ-61200 Brno 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Str Frunzei 29, Sector 2, Bucharest Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN
Phone: +420 5 414 24611, Fax: +420 5 412 18034 Phone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500 Phone: +40 213205111, Fax: +40 213261489 Phone: +44 (0)800 1382930 Fax: +44 (0)1908-555064
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
http://www.smc.cz http://www.smcpneumatics.ie http://www.smcromania.ro http://www.smcpneumatics.co.uk
http://www.smceu.com
http://www.smcworld.com
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
1st printing LU printing LU 00 UK Printed in Spain Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.