0% found this document useful (0 votes)
107 views16 pages

SFD 100

The document details the specifications and features of the SFD series clean air filters, which utilize a built-in hollow fibre element with a nominal filtration rating of 0.01µm and 99.99% efficiency. It outlines various models with different flow rates, operating pressures, and materials, including options for disposable and cartridge types. Additionally, it emphasizes the importance of clean assembly environments and quality control measures during production.

Uploaded by

Hertzio83
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views16 pages

SFD 100

The document details the specifications and features of the SFD series clean air filters, which utilize a built-in hollow fibre element with a nominal filtration rating of 0.01µm and 99.99% efficiency. It outlines various models with different flow rates, operating pressures, and materials, including options for disposable and cartridge types. Additionally, it emphasizes the importance of clean assembly environments and quality control measures during production.

Uploaded by

Hertzio83
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Clean Air Filter

Built-in Hollow Fibre Element


쎲 Nominal filtration rating: 0.01µm (filtration efficiency 99.99%)
쎲 Initial pressure drop: 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow)
쎲 Maximum operating pressure: 1.0 MPa (at 20°C)

SFD100 SFD200 SFD101/102 Made to Order


Up to 100 l/min Up to 500 l/min Up to 100 l/min

Restriction of Hazardous Substances


RoHS compliant
Series SFD
CAT.EUS120-5A-UK
Clear resin case
• Easy to confirm if an element is dirty.
• Polycarbonated a material is resistant
to alcohol-based cleaning solutions.

Two types of piping Replacement


ports are available: element
clean one-touch fitting and
female-threaded pipe fitting

SFD200

Can be disassembled.
(Cartridge type)
Replaceable hollow fibre elements

Made to Order

Stainless steel or
aluminum cases are available.
Metal case that is suitable for an atmosphere
exposed to organic solvents and chemicals.
(Fluids: Air and (Nitrogen))

SFD100 SFD200 SFD101 SFD102

Made to Order

Type Disposable type (non-replaceable element) Cartridge type (replaceable element)


Flow rate l/min (ANR) (at inlet pressure 0.7 MPa) Up to 60 Up to 80 Up to 100 Up to 300 Up to 400 Up to 500 Up to 100
One-touch fitting ø4 ø6 ø8 ø8 ø10 ø12 —
Port size Rc 1/4, G 1/4 Rc 1/4, G 1/4
Female thread — — NPT 1/4 — — NPT 1/4 Rc 1/4, G 1/4, NPT 1/4
Case material Resin Resin Aluminum Stainless steel
Fluid Air (Nitrogen)
Nominal filtration rating 0.01 µm (filtration efficiency: 99.99%) Note)
Initial pressure drop 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow)
Maximum operating pressure 1.0 MPa (in case of nitrogen: 0.99 MPa)
Operating temperature 5 to 45°C
Note) The clean air filter is designed for the filtration of solid objects. It is not suitable for the separation of water and oil.

Features 1
Integrated production in a clean environment
Under a clean environment, all components have undergone ultrasonic cleaning.
Assembly, inspection and antistatic double packaging processes are conducted in an integrated production system.

쎲 Quality Control 쎲
At the time of shipment, the SFD series clean air filter is 100% inspected.

Shipping inspection Assembly environment


쎲 Purification test
쎲 Clean room : M5.5 (ISO class 7)∗
쎲 Airtight test
쎲 Clean bench: M3.5 (ISO class 5)∗
∗ Fed. Std. 209E ( ): based on ISO14644-1.

Application Examples

Protection of
Clean blow precision equipment

• Substitution of
chamber
• Fluid pumping,
etc.
∗ When blowing, take care not to entrain ambient air
which could contaminate the workpieces.

Circuit Examples
Heatless
air dryer or
Refrigerated Membrane Super mist Fluid Clean blow
Air source After-cooler air dryer air dryer separator

Pumping of cleaning solvents


Air tank Main line Mist Micro mist Odour
filter separator separator removal
filter Air micro meter
Static paint

Paint
– +
∗ The equipment mounted to the secondary side of the SFD unit should be cleaned
by flushing and have the same level of cleanliness as the SFD unit.

Hollow fibre membrane


The hollow fibre membrane has a porous construction with numerous fine holes on a straw type fibre membrane wall.
These fine holes are distributed in layers, and the layers are overlapped between the external face and internal face of the mem-
brane.
The hollow fibre membrane filter traps and filtrates the impurities from the compressed air through the overlapping layered fine ho-
les.

Filter

(Image) Impurities (Image)

Features 2
Series SFD
Model Selection
Select the model by using the following procedures involving the inlet pressure and the maximum flow rate.
[Example] Inlet pressure: 0.6 MPa
Maximum flow rate: 100 l/min (ANR)
1. Obtain the intersection A for the inlet pressure and the maximum flow rate by using the maximum flow rate chart.
2. If the obtained intersection A is above the maximum flow rate line, the SFD200-C12, -쏔02, -C10, or -C08 can be selected.
Note) Please be sure to select a model which is above the obtained intersection A. If the obtained intersection A is below the maximum flow rate line, overflow will
occur. This will cause nonconformance in which the specification will not be satisfied.

Maximum Flow Rate

1000

SFD200-C12, -쏔02

SFD200-C08
SFD200-C10
Flow rate (l/min)

SFD100-C08, -쏔02
A
100

SFD100-04
SFD100-06

10
0 0.5 1

Pressure (MPa)

Front matter 1
Clean Air Filter

Series SFD
How to Order

SFD 1 0 0 C08
Clean air filter

Size
Option
Symbol Max. flow rate
Symbol Option
1 100 l/min (ANR)
- None
2 500 l/min (ANR)
B Bracket (SFD100 only)
∗ The brackets are provided with the SFD200
Case material series as standard. (-)
Symbol Material
0 Resin Port size
1 Aluminum Symbol Connection size Note
2 Stainless steel C04 ø4
SFD100 only
C06 ø6
Symbol 1 and 2 are made to order. Clean one-touch
C08 ø8 fitting (KP series) SFD100/200
For details, refer to page 5.
C10 ø10
SFD200 only
C12 ø12
02 Rc 1/4
Female thread
N02 NPT 1/4
SFD100/200
F02 G 1/4

Different diameters for IN and OUT ports are made to order.


For details, refer to page 6.
Relationship between
Operating Temperature and
Max. Operating Pressure Specifications

1.2 Model SFD10쏔 SFD20쏔


One-touch fitting ø4, ø6, ø8 One-touch fitting ø8, ø10, ø12
Port size
Rc, NPT, G 1/4 Rc, NPT, G 1/4
Max. operating pressure (MPa)

1.0 Fluid Air (Nitrogen) Air (Nitrogen)


Air flow capacity Up to 100 l/min (ANR) Up to 500 l/min (ANR)
0.8 Nominal filtration rating Note 1) 0.01 µm (99.99%)
Max. operating pressure Note 2) 1.0 MPa (in case of nitrogen: 0.99 MPa)
Operating temperature 5 to 45°C
0.6
Initial pressure drop 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow)
Element differential proof pressure Note 3) 0.5 MPa
0.4 Proof pressure 1.5 MPa
Element service life 1 year, or when the pressure drop reaches 0.1 MPa.
0.2 Note 1) Measured under SMC’s specified conditions.
Note 2) The maximum operating pressure is at 20°C. For other temperatures, refer to the figure on the left (rela-
tionship between the operating temperature and maximum operating pressure).
0 Note 3) This means that the element does not break at 0.5 MPa. See “Specific Product Precautions”.
0 10 20 30 40 50
Model Port size Rated flow (l/min (ANR)) Note) Weight
Operating temperature (°C)
ø4 (One-touch fitting) 60 35 g
ø6 (One-touch fitting) 80 35 g
SFD100 ø8 (One-touch fitting) 100 35 g
Rc, NPT, G 1/4 100 35 g
SFD101 Rc, NPT, G 1/4 100 60 g
SFD102 Rc, NPT, G 1/4 100 150 g
ø8 (One-touch fitting) 300 190 g
ø10 (One-touch fitting) 400 190 g
SFD200 ø12 (One-touch fitting) 500 190 g
Rc, NPT, G 1/4 500 260 g
Note) The maximum flow rate when the inlet pressure is 0.7 MPa.

1
Series SFD

Flow Characteristics

SFD100-C04 SFD200-C08
0.04 0.04

0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa 0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa
Pressure drop (MPa)

Pressure drop (MPa)


0.03 0.03
Max. flow rate line Max. flow rate line

0.02 0.02

0.9 MPa 0.9 MPa


0.01 0.01

0 0.00
0 20 40 60 0 100 200 300 400

Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

SFD100-C06 SFD200-C10
0.04 0.04

0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa 0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa
Pressure drop (MPa)

Pressure loss (MPa)

0.03 0.03
Max. flow rate line Max. flow rate line

0.02 0.02

0.9 MPa 0.9 MPa

0.01 0.01

0 0
0 20 40 60 80 100 0 100 200 300 400 500

Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

SFD100-C08, -02, -N02, -F02 SFD200-C12, -02, -N02, -F02


0.04 0.04

0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa 0.1 MPa 0.3 MPa 0.5 MPa 0.7 MPa
Pressure drop (MPa)

Pressure loss (MPa)

0.03 0.03
Max. flow rate line Max. flow rate line

0.02 0.02

0.9 MPa
0.9 MPa
0.01 0.01

0 0
0 20 40 60 80 100 120 0 100 200 300 400 500 600

Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

2
Clean Air Filter Series SFD

Construction
SFD100-C쏔 Component Parts
No. Description Material Note
tyui r q w Element
1 Case: Clear resin
2 Cover Resin
3 Bracket Resin
4 O-ring Rubber
5 Seal Rubber
6 Cushion Rubber
7 Stopper Stainless steel alloy
8 Cassette Stainless steel alloy

e Replacement Parts
No. Description Part no. Note
With 2 countersunk
1 Bracket set SFD-BR100
SFD100-쏔02 head screws (M3)

r q w Component Parts
No. Description Material Note
1 Element Case: Clear resin
2 Cover Resin
3 Bracket Resin
4 O-ring Rubber
Replacement Parts
No. Description Part no. Note
With 2 countersunk
1 Bracket set SFD-BR100 head screws (M3)
e
Component Parts
SFD200-C쏔 No. Description Material Note
1 Element Case: Clear resin
2 Cover Aluminum alloy
r t yu o q !1 w e !2 !4 3 Fitting body Resin
4 Seal Rubber
5 Cushion Rubber
6 Stopper Stainless steel alloy
7 Cassette Stainless steel alloy
8 Bracket Stainless steel alloy
9 O-ring A Rubber
10 O-ring B Rubber
11 Rod cover Stainless steel alloy
12 Tie-rod Stainless steel alloy
i !0 !3 13 Cap nut General type steel Nickel plated
14 Plain washer General type steel Nickel plated
Replacement Parts
No. Description Part no. Note
1 Element set SFD-EL200 With 3 O-rings

Component Parts
SFD200-쏔02 No. Description Material Note
1 Element Case: Clear resin
t q u w e !0 i 2 Cover Aluminum alloy
3 Fitting body Stainless steel alloy
4 Bracket Stainless steel alloy
5 O-ring A Rubber
6 O-ring B Rubber
7 Rod cover Stainless steel alloy
8 Tie-rod Stainless steel alloy
9 Cap nut General type steel Nickel plated
10 Plain washer General type steel Nickel plated
Replacement Parts
r y o
No. Description Part no. Note
1 Element set SFD-EL200 With 3 O-rings

3
Series SFD

Dimensions
SFD100-C쏔 SFD100-C쏔 Dimensions
Model A B
ø2 C04 4 83
3
SFD100- C06 6 83
C08 8 84
SMC
26
23
15

17 51
72 Bracket mounting dimensions
27
Applicable tubing O.D. øA B 42

16
SFD100-쏔02
ø2
3

Hole shape for bracket mounting


SMC
26
23
15

90°

1.5
3
17 51
∗ Use a countersunk head screw
27 72 (M3) for bracket mounting.
ø3.5

SFD200-C쏔 SFD200-C쏔 Dimensions


Model A B
C08 8 127
SFD200- C10 10 128
C12 12 128
SMC
42
24

96.5 Bracket mounting dimensions


36
114.5
4 x 3.5

4x7
Applicable tubing O.D. øA B
28

SFD200-쏔02
103.5

SMC
42
24

19 96.5
36 114.5

4
Series SFD
Made to Order 1
Contact SMC for detailed specifications, delivery and prices.

1 Metal Case
Metal case that is suitable for an

SFD 1 0 1 02 atmosphere exposed to organic


solvents and chemicals.

Clean air filter Port size


Symbol Connection size
Size 02 Rc 1/4
Symbol Max. flow rate N02 NPT 1/4
1 100 l/min (ANR) F02 G 1/4 Specifications
∗ The SFD2 is not applicable. ∗ The metal case is not available with
a clean one-touch fitting. The specifications are the same as the standard product.
∗ The bracket is provided as standard. Refer to “Specifications” on page 1.
Case material
Symbol Material
1 Aluminum Flow Characteristics
2 Stainless steel
The flow characteristics are the same as the SFD100-02.
Refer to “Flow Characteristics” on page 2.

Construction
SFD101-02 SFD102-02
q e r w q e r t w

Component Parts Component Parts


No. Description Material Note No. Description Material Note
1 Case Aluminum alloy 1 Case Stainless steel alloy
2 Cover Aluminum alloy 2 Cover Stainless steel alloy
3 Element Case: Clear resin 3 Element Case: Clear resin
4 O-ring Rubber 4 Hex. socket head set screw Stainless steel alloy
5 O-ring Rubber

Replacement Parts Replacement Parts


No. Description Part no. Note No. Description Part no. Note
1 Element set SFD-EL101 With O-ring 1 Element set SFD-EL101 With O-ring
2 Bracket SFD-BR101 2 Bracket SFD-BR101

Dimensions
SFD101-02 SFD102-02
66 25 66 25
19 19

ø2 ø2
4 4
50
40

50
40

Bracket 2 x ø4.5 Bracket 2 x ø4.5


13 13

5
Series SFD
Made to Order 2
Contact SMC for detailed specifications, delivery and prices.

2 Different Diameters for IN and OUT Ports

SFD 1 0 0 C04 C06


Clean air filter
Option
Size Symbol Option
Symbol Max. flow rate - None
1 100 l/min (ANR) Case material Bracket
B
2 500 l/min (ANR) Symbol Material (SFD100 only)
0 Resin ∗ The brackets are provided
with the SFD200 series as
standard. (-)

IN side connection symbol OUT side connection symbol


IN side OUT side
Connection size Connection size
connection symbol connection symbol
C04 ø4 C04 ø4
C06 ø6 C06 ø6 Specifications
Clean one-touch Clean one-touch
C08 ø8 C08 ø8
fitting (KP series) fitting (KP series) The specifications are the same as the stan-
C10 ø10 C10 ø10
dard models.
C12 ø12 C12 ø12
Refer to “Specifications” on page 1.
02 Rc 1/4 02 Rc 1/4
N02 NPT 1/4 N02 NPT 1/4
F02 G 1/4 F02 G 1/4 Flow Characteristics
∗ IN/OUT combination is the below table.
When the IN and OUT ports have different dia-
meters, the flow characteristics will be the same
SFD100 Different Diameter Combinations SFD200 Different Diameter Combinations as those of the port with the smaller diameter.
OUT port size OUT port size Refer to “Flow Characteristics” for the smaller
C04 C06 C08 02 N02 F02 C08 C10 C12 02 N02 F02 diameter from the charts of standard products
C04 쏹 — 쏹 쏹 쏹 C08 쏹 — 쏹 쏹 쏹 on page 2.
쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹
IN port size

C06
IN port size

C10
C08 — 쏹 쏹 쏹 쏹 C12 — 쏹 쏹 쏹 쏹
02 쏹 쏹 쏹 — — 02 쏹 쏹 쏹 — —
Construction
N02 쏹 쏹 쏹 — — N02 쏹 쏹 쏹 — — The construction and materials are the same as
F02 쏹 쏹 쏹 — — F02 쏹 쏹 쏹 — — the standard product.
∗ The symbol “—” stands for unavailable combination. ∗ The symbol “—” stands for unavailable combination. Refer to “Construction” on page 3.

Dimensions
SFD100 different diameters SFD200 different diameters
One-touch
One-touch fitting
fitting dimensions
dimensions Port size q Port size w
Port size q Port size w
ø4 ø8
5.5 SMC 6.5

ø6 Basic dimension 72 ø10 Basic dimension 114.5


Fitting Fitting Fitting Fitting
5.5 dimension A dimension B 6.5 dimension A dimension B

ø8 ø12

6 6.5

Model Port size q Port size w Total length Model Port size q Port size w Total length
C04 (C06) C06 (C04) 83 (A + 72 + B) C08 (C10) C10 (C08) 127.5 (A + 114.5 + B)
C04 (쏔02) 쏔02 (C04) 77.5 (72 + A) C08 (쏔02) 쏔02 (C08) 121 (114.5 + A)
SFD100- C06 (C08) C08 (C06) 83.5 (A + 72 + B) SFD200- C10 (C12) C12 (C10) 127.5 (A + 114.5 + B)
C06 (쏔02) 쏔02 (C06) 77.5 (72 + A) C10 (쏔02) 쏔02 (C10) 121 (114.5 + A)
C08 (쏔02) 쏔02 (C08) 78 (72 + A) C12 (쏔02) 쏔02 (C12) 121 (114.5 + A)

6
Related Products
< Pre-filters for Series SFD >
For details, refer to SMC's “Best Pneumatics” catalogue.

Mist Separator Series AM


Series AM Specifications
Model AM150 AM250 Fluid Compressed air
Rated flow (l/min (ANR)) 300 750 Max. operating pressure 1.0 MPa
Port size (Rc, G, NPT) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 Min. operating pressure Note) 0.05 MPa
Proof pressure 1.5 MPa
Ambient temperature 5 to 60°C
0.3 µm (95%
Nominal filtration rating particle size
collection)
Note) With auto drain: 0.1 MPa (N.O. type), 0.15 MPa
(N.C. type)

Micro Mist Separator Series AMD


Series AMD Specifications
Model AMD150 AMD250 Fluid Compressed air
Rated flow (l/min (ANR)) 200 500 Max. operating pressure 1.0 MPa
Port size (Rc, G, NPT) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 Min. operating pressure Note) 0.05 MPa
Proof pressure 1.5 MPa
Ambient temperature 5 to 60°C
0.01 µm (95%
Nominal filtration rating particle size
collection)
Note) With auto drain: 0.1 MPa (N.O. type), 0.15 MPa
(N.C. type)

Super Mist Separator Series AME


Series AME Specifications
Model AME150 AME250 Fluid Compressed air
Rated flow (l/min (ANR)) 200 500 Max. operating pressure 1.0 MPa
Port size (Rc, G, NPT) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 Min. operating pressure 0.05 MPa
Proof pressure 1.5 MPa
Ambient temperature 5 to 60°C
0.01 µm (95%
Nominal filtration rating particle size
collection)

Odour Removal Filter Series AMF


Series AMF Specifications
Model AMF150 AMF250 Fluid Compressed air
Rated flow (l/min (ANR)) 200 500 Max. operating pressure 1.0 MPa
Port size (Rc, G, NPT) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 Min. operating pressure 0.05 MPa
Proof pressure 1.5 MPa
Ambient temperature 5 to 60°C
0.01 µm (95%
Nominal filtration rating particle size
collection)

7
Related Products
Ionizer Series IZS31
Controlled ion balance by sensor Ionizer model IZS31-쏔쏔 (NPN spec.) IZS31-쏔쏔P (PNP spec.)
쎲 Rapid elimination of static electri- Ion generation method Corona discharge type
city by a feedback sensor Method of applying voltage Sensing DC, Pulse DC, DC
쎲 Ion balance control by an autoba- Output for emitting electricity ±7000 V
Ion balance Note 1) ±30 V (in the case of stainless steel electrode needle ±100 V)
lance sensor
Fluid Air (clean and dry)
Air purge Operating pressure 0.7 MPa or less
Connecting tubing O.D. ø4
Electrode needle material Tungsten, Silicon, Stainless steel
Note 1) For the case where air purge is performed between a charged object and an ionizer at a distance of 300 mm.
Ionizer Note 2) When measuring the potential of a charged object with a feedback sensor, the relationship between
measured charge potential and sensor monitor output voltage and the sensor detecting range will differ
according to the sensor installation distance.

Electrode Cartridge Number, Weight


Bar length (mm) 300 380 620 780 1100 1260 1500 1900 2300
Electrode cartridge
3 4 7 9 13 15 18 23 28
number
Feedback Autobalance
sensor sensor Weight (g) 470 530 720 850 1100 1220 1410 1730 2040

Clean Regulator Series SR


Series SRP1000 Series SRP1000
Port size Wetted parts material
Series
M5 1/8 Body Diaphragm
SRP1000 Stainless steel 316L Wetted parts
(Stainless steel 316 PTFE + Fluorine
for wetted parts) rubber (Grade A)
Fluorine rubber (Grade B)

Stainless steel regulator controlled Series SRH


for contamination Port size Rc (PT) Wetted parts material
Series
1/8 1/4 3/8 1/2 9/16-18UNF 7/8-14UNF Body Diaphragm
Series SRH
SRH3000 Stainless steel 316L Wetted parts
(Stainless steel 316 PTFE + Fluorine
SRH4000
for wetted parts) rubber (Grade A)
Fluorine rubber (Grade B)

Clean Gas Filter Series SF


Nominal filtration rating 0.01 µm Cartridge Type
Series SFA Main material Thread Port size
Series Type
Element Housing Seal type M5 1/4
100 PTFE
SFA 200 Disc + Stainless Rc (PT)
Fluorine NPT
300 Polyester steel 316
rubber
Series SFB PTFE (Electro-
(FPM)
TSJ
SFB100 Straight + polishing) UOJ
PFA

Disposable Type
Main material Thread Port size
Series SFC Series Type
Element Housing Seal type 1/4 3/8
PTFE
SFB300 Straight + Stainless — Rc (PT)
PFA steel 316
TSJ
PTFE (Electro- O-ring
Multiple + URJ
SFC100 polishing) PTFE
disc PVDF

8
Series SFD

Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These
instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To
ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices.
쐽Explanation of the Labels
Labels Explanation of the labels

Danger In extreme conditions, there is a possible result of serious injury or loss of life.

Warning Operator error could result in serious injury or loss of life.

Caution Operator error could result in injury Note 3) or equipment damage. Note 4)

Note 1) ISO 4414: Pneumatic fluid power – General rules relating to systems
Note 2) JIS B 8370: General Rules for Pneumatic Equipment
Note 3) Injury indicates light wounds, burns and electrical shocks that do not require hospitalisation or hospital visits for long-term medical treatment.
Note 4) Equipment damage refers to extensive damage to the equipment and surrounding devices.

쐽Selection/Handling/Applications
1. The compatibility of the pneumatic equipment is the responsibility of the person who designs the
pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system
must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and
safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should
continuously review the suitability of all items specified, referring to the latest catalogue information with a view to giving due
consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery and equipment.
Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of the systems using pneumatic equipment
should be performed by trained and experienced operators. (Understanding JIS B 8370 General Rules for Pneumatic Equipment,
and other safety rules are included.)
3. Do not service machinery/equipment or attempt to remove components until safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway
of the driven objects have been confirmed.
2. When equipment is removed, confirm the safety process as mentioned above. Turn off the supply pressure for this equipment
and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity).
3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc.
4. If the equipment will be used in the following conditions or environment, please contact SMC first and
be sure to take all necessary safety precautions.
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and
beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, requiring special safety analysis.
4. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for
the prevention of a breakdown. And, examine the devices periodically if they function normally or not.

쐽Exemption from Liability


1. SMC, its officers and employees shall be exempted from liability for any loss or damage arising out of
earthquakes or fire, action by a third person, accidents, customer error with or without intention, pro-
duct misuse, and any other damages caused by abnormal operating conditions.
2. SMC, its officers and employees shall be exempted from liability for any direct or indirect loss or dama-
ge, including consequential loss or damage, loss of profits, or loss of chance, claims, demands, pro-
ceedings, costs, expenses, awards, judgments and any other liability whatsoever including legal costs
and expenses, which may be suffered or incurred, whether in tort (including negligence), contract,
breach of statutory duty, equity or otherwise.
3. SMC is exempted from liability for any damages caused by operations not contained in the catalogues
and/or instruction manuals, and operations outside of the specification range.
4. SMC is exempted from liability for any loss or damage whatsoever caused by malfunctions of its pro-
ducts when combined with other devices or software.

Back page 1
Series SFD
Specific Product Precautions 1
Be sure to read this before handling. Refer to the back of page 1 for Safety Instructions
and “Precautions for Handling Pneumatic Devices (M-03-E3A) for Common Precautions.

Selection Caution on Installation

Warning Warning
1. Thoroughly and carefully confirm the purpose 1. The material of the element is polycarbonate.
of use, required specifications and operating The material is resistant to wiping with alcohol, but is not
conditions (fluid, pressure, flow rate, nominal suitable for atmospheres or places with organic solvents,
chemicals, cutting oils, synthetic oils, ester base compressor
filtration rating and environment) then select oils, alkalis or thread locking agents.
a model within the specifications.
2. The product is not certified under the High Caution
Pressure Gas Safety law, so for nitrogen, its
maximum operating pressure will be 0.99 1. If the pressure difference (pressure drop)
MPa (gauge pressure). between the inlet and the outlet exceeds 0.1
MPa, it can cause damage to the product.
3. Contact SMC beforehand if the product will
be used in an application such as a caisson 2. Do not install the product in a place where it
shield, breathing, food and/or medical treat- can be affected by a pulsation (including
ment that affects the human body directly or surge pressure) of over 0.1 MPa.
indirectly. 3. Use caution regarding the particles that may
4. If the compressed air includes ozone, do not be emitted from the outlet side of pneumatic
use it since it may damage the product or equipment.
Installation of pneumatic equipment on the outlet side can
cause malfunction. When it includes ozone, deteriorate the cleanliness because a particle will be gener-
use a clean gas filter (SFA/B/C). ated from the equipment.
The mounting position of the pneumatic equipment needs to
Mounting be considered.
4. Set the air flow capacity with an initial pres-
Warning sure drop of 0.03 MPa or less. If the initial
1. Instruction manual pressure drop is set to be high, its service
Mount the product after reading and understanding the life will be shorten due to clogging.
instruction manual. Keep it in a location where it can easily be 5. Determine the product by the maximum con-
found. sumption flow rate.
2. Flushing When using compressed air for an air blow application, calcu-
Flush the piping line when the filter is used for the first time or late the maximum volume of air that will be consumed before
has been replaced. In the event of connecting such as piping, selecting the SFD series product size.
flush (air blow) when using this product for the first time or 6.Generally, the following pollutant particles
replacing its elements in order to reduce the affect of the dust
generated from the connection, etc. Flushing the line is also are contained in compressed air.
required to eliminate contamination resulting from the piping [Pollutant particle substances contained in the
line installation. Therefore, be sure to flush the line before compressed air]
actually running the system. Fix all mounting parts for use. • Moisture (drainage)
• Dusts and particles which are in the surrounding air
3.Use fittings with resin threads for the con- • Deteriorated oil which is discharged from the compressor
nection of fittings to the IN and OUT ports. • Solid foreign matter such as rust and/or oil in the piping
Using fittings with metal threads could damage the IN and
1) The SFD series is not compatible with compressed air
OUT ports.
which contains fluids such as water and/or oil.
4. Connect tubing to the IN and OUT one-touch 2) Install a dryer (IDFA, IDG series), mist separator (AM
fittings in accordance with the precautions series), micro mist separator (AMD series), super mist
for one-touch fittings. separator (AME series), or odour removal filter (AMF
series), etc., for the source of the air for the SFD series.

Caution 7. Using with a flow-rate much higher than its


specification could lead to exceeding the
1. Connect the piping in accordance with the differential pressure the product can resist.
flow direction marked on the case. Use the product within its specifications. Also, take care about
If connected in reverse, the element could break. the replacement period of the product, taking into consider-
ation that the differential pressure of the filter will increase
2. The mounting orientation does not affect the over time.
performance, but if excessive force is
applied to the SFD100 series, the body may
become disconnected from the bracket.
Therefore, take particular care about the mounting orientation.
Back page 2
Series SFD
Specific Product Precautions 2
Be sure to read this before handling. Refer to the back of page 1 for Safety Instructions
and “Precautions for Handling Pneumatic Devices (M-03-E3A) for Common Precautions.

Piping Operating Environment

Caution Warning
1. Unpacking the sealed package 1. Do not operate under the conditions listed
Since the filter is sealed in an antistatic double bag, the inner below due to a risk of malfunction.
package should be unpacked in a clean atmosphere (such as In locations having corrosive gases, organic solvents, and
a clean room). chemical solutions, or in locations in which these elements are
2. Apply a wrench to the 2 chamfered flats or likely to adhere to the equipment.
In locations in which salt water, water, or water vapour could
hexagon portion on the IN side or the OUT come in contact with the equipment.
side to prevent the housing from rotating. In locations that are exposed to direct sunlight. (Shield the
3. Always tighten threads with the proper tigh- equipment from sunlight to prevent its resin material from
ultraviolet ray degradation or overheating.)
tening torque. In locations that have a heat source and poor ventilation.
When attaching fittings to the product, tighten with the proper (Shield the equipment from heat sources to protect it from
tightening torque shown below. softening degradation due to radiated heat.)
In locations that are exposed to shocks and vibrations.
Material Tightening torque (N ·m) In locations with high humidity or a large amounts of dust.
Resin 2 to 3
Metal 12 to 14
2. When the product is used for blowing, use
caution to prevent the work from being
4. Check the arrow mark on the case which damaged by entrained air from the
shows the flow direction to connect the IN surrounding area.
When the compressed air is used for air blow, the exhausted
and OUT ports correctly. air from the blow nozzle may have taken in airborne foreign
If connected in reverse, the element could break. matter (such as solid particle, fluid particle) from the
surrounding air. The foreign matter will be sprayed onto the
work, and the airborne foreign matter may adhere to it.
Maintenance Therefore, use caution for the surrounding environment.

Warning Other Tube Brands


1. Follow the maintenance procedures in the
instruction manual. If handled incorrectly, Caution
equipment or device can be damaged or
cause a malfunction. 1.When tubing of brands other than SMC’s are
used, verify that the tubing O.D. satisfies the
2. When removing the product, exhaust the air following accuracy;
and ensure the air is released to atmosphere 1) Polyolefin tube: Within ±0.1 mm
before removing it. 2) Polyurethane tubing: Within +0.15 mm, within –0.2 mm
3. When the element comes to the end of its li- 3) Nylon tubing: Within ±0.1 mm
4) Soft nylon tubing: Within ±0.1 mm
fe, immediately replace it with a new filter or
Do not use tubing which does not meet these outside diameter
replacement element (cartridge type). tolerances. It may not be possible to connect them, or they
Service life of element may cause other trouble, such as air leakage or the tube pu-
The service life of the element ends when either of the follo- lling out after connection.
wing two conditions occurs. The recommended tube for the clean fitting is polyolefin tube.
Other tubes can satisfy the performance in terms of leakage,
1) After 1 year of usage has elapsed.
tensile strength, etc., but may impair the cleanliness. Note this
2) When the pressure drop reaches 0.1 MPa even though the point for use.
operating period has been less than 1 year.

Back page 3
EUROPEAN SUBSIDIARIES:

Austria France Netherlands Spain


SMC Pneumatik GmbH (Austria). SMC Pneumatique, S.A. SMC Pneumatics BV SMC España, S.A.
Girakstrasse 8, A-2100 Korneuburg 1, Boulevard de Strasbourg, Parc Gustave Eiffel De Ruyterkade 120, NL-1011 AB Amsterdam Zuazobidea 14, 01015 Vitoria
Phone: +43 2262-62280, Fax: +43 2262-62285 Bussy Saint Georges F-77607 Marne La Vallee Cedex 3 Phone: +31 (0)20-5318888, Fax: +31 (0)20-5318880 Phone: +34 945-184 100, Fax: +34 945-184 124
E-mail: [email protected] Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010 E-mail: [email protected] E-mail: [email protected]
http://www.smc.at E-mail: [email protected] http://www.smcpneumatics.nl http://www.smces.es
http://www.smc-france.fr

Belgium Germany Norway Sweden


SMC Pneumatics N.V./S.A. SMC Pneumatik GmbH SMC Pneumatics Norway A/S SMC Pneumatics Sweden AB
Nijverheidsstraat 20, B-2160 Wommelgem Boschring 13-15, D-63329 Egelsbach Vollsveien 13 C, Granfos Næringspark N-1366 Lysaker Ekhagsvägen 29-31, S-141 71 Huddinge
Phone: +32 (0)3-355-1464, Fax: +32 (0)3-355-1466 Phone: +49 (0)6103-4020, Fax: +49 (0)6103-402139 Tel: +47 67 12 90 20, Fax: +47 67 12 90 21 Phone: +46 (0)8-603 12 00, Fax: +46 (0)8-603 12 90
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
http://www.smcpneumatics.be http://www.smc-pneumatik.de http://www.smc-norge.no http://www.smc.nu

Bulgaria Greece Poland Switzerland


SMC Industrial Automation Bulgaria EOOD SMC Hellas EPE SMC Industrial Automation Polska Sp.z.o.o. SMC Pneumatik AG
16 kliment Ohridski Blvd., fl.13 BG-1756 Sofia Anagenniseos 7-9 - P.C. 14342. N. Philadelphia, Athens ul. Konstruktorska 11A, PL-02-673 Warszawa, Dorfstrasse 7, CH-8484 Weisslingen
Phone:+359 2 9744492, Fax:+359 2 9744519 Phone: +30-210-2717265, Fax: +30-210-2717766 Phone: +48 22 548 5085, Fax: +48 22 548 5087 Phone: +41 (0)52-396-3131, Fax: +41 (0)52-396-3191
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
http://www.smc.bg http://www.smchellas.gr http://www.smc.pl http://www.smc.ch

Croatia Hungary Portugal Turkey


SMC Industrijska automatika d.o.o. SMC Hungary Ipari Automatizálási Kft. SMC Sucursal Portugal, S.A. Entek Pnömatik San. ve Tic Ltd. Sti.
Crnomerec 12, 10000 ZAGREB Budafoki ut 107-113, H-1117 Budapest Rua de Engº Ferreira Dias 452, 4100-246 Porto Perpa Tic. Merkezi Kat: 11 No: 1625, TR-80270 Okmeydani Istanbul
Phone: +385 1 377 66 74, Fax: +385 1 377 66 74 Phone: +36 1 371 1343, Fax: +36 1 371 1344 Phone: +351 22-610-89-22, Fax: +351 22-610-89-36 Phone: +90 (0)212-221-1512, Fax: +90 (0)212-221-1519
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
http://www.smc.hr http://www.smc.hu http://www.smces.es http://www.entek.com.tr

© DiskArt™ 1988

Czech Republic Ireland Romania © DiskArt™

UK
SMC Industrial Automation CZ s.r.o. SMC Pneumatics (Ireland) Ltd. SMC Romania srl SMC Pneumatics (UK) Ltd
Hudcova 78a, CZ-61200 Brno 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Str Frunzei 29, Sector 2, Bucharest Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN
Phone: +420 5 414 24611, Fax: +420 5 412 18034 Phone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500 Phone: +40 213205111, Fax: +40 213261489 Phone: +44 (0)800 1382930 Fax: +44 (0)1908-555064
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
http://www.smc.cz http://www.smcpneumatics.ie http://www.smcromania.ro http://www.smcpneumatics.co.uk

Denmark Italy Russia


SMC Pneumatik A/S SMC Italia S.p.A SMC Pneumatik LLC.
Knudsminde 4B, DK-8300 Odder Via Garibaldi 62, I-20061Carugate, (Milano) 4B Sverdlovskaja nab, St. Petersburg 195009
Phone: +45 70252900, Fax: +45 70252901 Phone: +39 (0)2-92711, Fax: +39 (0)2-9271365 Phone.:+812 718 5445, Fax:+812 718 5449
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
http://www.smcdk.com http://www.smcitalia.it http://www.smc-pneumatik.ru

Estonia Latvia Slovakia


SMC Pneumatics Estonia OÜ SMC Pneumatics Latvia SIA SMC Priemyselná Automatizáciá, s.r.o.
Laki 12-101, 106 21 Tallinn Smerla 1-705, Riga LV-1006, Latvia Námestie Martina Benku 10, SK-81107 Bratislava
Phone: +372 (0)6 593540, Fax: +372 (0)6 593541 Phone: +371 781-77-00, Fax: +371 781-77-01 Phone: +421 2 444 56725, Fax: +421 2 444 56028
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
http://www.smcpneumatics.ee http://www.smclv.lv http://www.smc.sk

Finland Lithuania Slovenia


SMC Pneumatics Finland Oy SMC Pneumatics Lietuva, UAB SMC industrijska Avtomatika d.o.o.
PL72, Tiistinniityntie 4, SF-02031 ESPOO Savanoriu pr. 180, LT-01354 Vilnius, Lithuania Grajski trg 15, SLO-8360 Zuzemberk
Phone: +358 207 513513, Fax: +358 207 513595 Phone: +386 738 85240 Fax: +386 738 85249
E-mail: [email protected] Phone: +370 5 264 81 26, Fax: +370 5 264 81 26
E-mail: [email protected]
http://www.smc.fi http://www.smc.si

OTHER SUBSIDIARIES WORLDWIDE:


ARGENTINA, AUSTRALIA, BOLIVIA, BRASIL, CANADA, CHILE,
CHINA, HONG KONG, INDIA, INDONESIA, MALAYSIA, MEXICO,
NEW ZEALAND, PHILIPPINES, SINGAPORE, SOUTH KOREA,
TAIWAN, THAILAND, USA, VENEZUELA

http://www.smceu.com
http://www.smcworld.com
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
1st printing LU printing LU 00 UK Printed in Spain Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.

You might also like