The document provides detailed information about a standalone access control and proximity card reader that supports EM and MF card types, featuring a microprocessor for enhanced security and functionality. It includes installation instructions, specifications, wiring details, and advanced settings for user management, such as adding or deleting users and changing codes. Additionally, it outlines sound and light indications for various operational statuses and data backup operations.

Uploaded by

berserk98k
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views

K12-Manual

The document provides detailed information about a standalone access control and proximity card reader that supports EM and MF card types, featuring a microprocessor for enhanced security and functionality. It includes installation instructions, specifications, wiring details, and advanced settings for user management, such as adding or deleting users and changing codes. Additionally, it outlines sound and light indications for various operational statuses and data backup operations.

Uploaded by

berserk98k
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

1.Description 4.Installation 6.

Diagram
The device is a standalone access control and proximity card reader which Drill hole according to the size of the device and fix the back shell with the 6.1 Common Power Supply 6.2 Special Power Supply
supports EM & MF card types. It builds-in STC microprocessor, with strong equipped screw.Thread the cable through the cable hole. connect the wires
anti-interference ability,high security and reliability,powerful function and according to your required function, and wrap the unused wires to avoid
convenient operation. It’s widely used in high-end buildings, residential short circuit. After connecting the wire, install the machine. (as show below)
communities and other public places.
Pink

Pink
2.Features Pink
Doorbell Pink
Doorbell
Ultra-low Power Standby current is less than 30mA
Green
Wiegand Interface WG26 or WG34 input and output Green
Searching time Less than 0.1s after reading card
Backlight keypad Operate easily at night White White
Electric control lock
Doorbell interface Support external wired doorbell
Yellow
Access ways Card, Pin code, Card & Pin code Yellow
Exit button
Exit button

Special power supply


Independent codes Use codes without related card Purple Magnetic lock

Change codes Users can change codes by themselves Purple


Black
Delete users by card No. The lost card can be delete by keyboard
5. Wiring Black Red

Color ID Description
Green D0 Wiegand Input(Wiegand Output in Card Reader Mode) Orange Magnetic lock Blue
White D1 Wiegand Input(Wiegand Output in Card Reader Mode)
Yellow OPEN Exit Button input terminal Red Orange
3. Specifications Red +12V 12V + DC Regulated Power Input
Black GND 12V - DC Regulated Power Input
Working VoltageDC12-24V Standby Current≤30mA Blue
Blue NO Relay normally-on terminal
Card Reading Distance1 ~3cm Capacity 2000 users
Purple COM Relay Public terminal
Working Temperature-40℃ 60℃ Working Humidity10%90%
Orange NC Relay normally-off terminal
Lock output load≤3A Door Relay time0 99S Adjustable
Pink BELL_A Doorbell button one terminal
Pink BELL_B Doorbell button to the other terminal

1 2 3 4
7.Sound & Light indication
6.3 Reader Mode
Operate Status LED Light Color Buzzer Change the 10.Data Backup Operation
Standby Red Access ways code by Read card New code # Repeat new Code # Example: Backup the data of machine A to machine B
Keypad Beep * user card
By card Only the card user could unlock The green wire and white wire of machine A connects with the green wire and
Green Beep Master code # 30 # the door, keypad is invalid Change the
Operation Successful Old code # New code # Repeat new Code # white wire of machine B correspondingly, set B for receiving mode at first, then
3 code by ID
Operation Failed Beep-Beep-Beep set A for sending mode, the indicator light turns green flash during the data
By card+ Master code # 31 # To enable this function, the user number added Note: All of codes will be modified except public code.
Pink Entering into Programming Flash Red Slowly Beep PIN code PIN code has to be changed. backup, data backup is successful when indicator light turns red.
Power off, press the exit button continuously, power on, hearing
Programmable Status Orange By card or Both card user and PIN user could
Master code # 32 # beep sound twice, meanwhile, the indicator light turns orange,
Exit Programming Red Beep PIN code unlock the door (factory default) swipe the first card as for master add card, swipe the second
Pink Reset to
Doorbell
Door Opening Green Beep Factory card as for the master delete card, the master code has been
Relay Output Delay Time
4 Default reset to 999999, factory default settings are successful.
Door relay Master code # 4 Door opening time range: 0-99s Registered user data won’t be deleted when reset to factory
Green 8. Advance setting strike time 0~99 # Default 5s default
Add Users Notes
White Change Master code # 0 Default factory master Standalone The door will be locked 9.Master Card Operation
Master code is 999999. access Master code # 50 # automatically after open the door 9.1 Add Card
code New code # New code #
control mode normally
5 Read master add card Read the 1st user card Read the 2nd user card …
Yellow The door will not be locked
Master code # 1 Cards can be added
Add card Relay toggle Master code # 51 # automatically.To lock the door, the Read master add card
Read card # … # continuously user has to read the card or press
mode
the exit button.
Master code # 1 Note: The master add card is used to add card users continuously and quickly.
Red Add card Card number can be added
1 number 8 digits or 10 digits # continuously Master code # 52 When you read the master add card at the first time, you will hear short "BEEP"
Reader WG26/34 input and output
mode 26/34 # sound twice and the indicator light turns orange, it means you have entered into
Black Add ID Master code # 1 Add user with specify ID add user programming. When you read the master add card at the second time,
number+ number, easily find and
card ID number # Read card # delete. you will hear long "BEEP" sound once and the indicator light turns red, it means
Access controller Bind a code Master code # 6 When using card+code to unlock
6 to a specific you have exited the add user programming.
Add ID Master code # 1 ID number Add user with specify ID card
Read card 4 digits code # the door
Blue number+ number, easily find and
card number # 8 digits or 10 digits # delete. 9.2 Delete Card
Data backup Master code # 70 # Send the data to external device.
Add PIN Master code # 1 ID number output
Purple code ID number is from 1-1000 Read master delete card Read the 1st user card Read the 2nd user card …
# 4 digits Pin code # 7 Data backup
Master code # 71 # The device will receive the data.
input Read master delete card
Delete Users
Orange Master code # 2 Only one public code is available. Note: The master delete card is used to delete card users continuously and quickly.
9 Add public Master code # 9
Read card or Cards can be deleted Delete public code: When you read the master delete card at the first time, you will hear short "BEEP"
Delete card continuously code 4 digits code #
2 Master code # 9 #
8 digits or 10 digits # sound twice and the indicator light turns orange, it means you have entered into delete
user programming. When you read the master delete card at the second time, you will
Master code # 2 When the card is broken or
Delete lost, you can delete the hear long "BEEP" sound once, the indicator light turns red, it means you have exited
ID number ID number # user by ID number the delete user programming.
Delete Master code # 2 0000 # Delete ALL PIN code & card
ALL users users except public PIN code