Lamer

The Current Transducer LA 55-P is designed for electronic measurement of DC, AC, and pulsed currents with galvanic separation between primary and secondary circuits, featuring a nominal RMS current of 50 A. It offers high accuracy, excellent linearity, and a wide frequency bandwidth, making it suitable for various applications including AC variable speed drives and uninterruptible power supplies. The device complies with safety standards and includes insulation coordination for safe operation in electric/electronic equipment.

Uploaded by

Anantha Keshava
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views3 pages

Lamer

The Current Transducer LA 55-P is designed for electronic measurement of DC, AC, and pulsed currents with galvanic separation between primary and secondary circuits, featuring a nominal RMS current of 50 A. It offers high accuracy, excellent linearity, and a wide frequency bandwidth, making it suitable for various applications including AC variable speed drives and uninterruptible power supplies. The device complies with safety standards and includes insulation coordination for safe operation in electric/electronic equipment.

Uploaded by

Anantha Keshava
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Current Transducer LA 55-P IP N = 50 A

For the electronic measurement of currents: DC, AC, pulsed...,


with galvanic separation between the primary circuit and the secondary
circuit.

Electrical data
IP N Primary nominal RMS current 50 A
IP M Primary current, measuring range 0 … ±70 A Features
RM Measuring resistance @ TA = 70 °C TA = 85 °C
RM min RM max RM min RM max ● Closed loop (compensated)
with ±12 V @ ±50 A max 10 100 60 95 Ω current transducer using the Hall
@ ±70 A max 10 50 60 1) 60 1) Ω effect
with ±15 V @ ±50 A max 50 160 135 155 Ω ● Insulating plastic case recognized
@ ±70 A max 50 90 135 2) 135 2) Ω according to UL 94-V0.
IS N Secondary nominal RMS current 50 mA
Advantages
NP/NS Turns ratio 1 : 1000
UC Supply voltage (±5 %) ±12 ... 15 V ● Excellent accuracy
Min Typ Max ● Very good linearity
IC Current consumption @ ±15 V 8 + IS 10 + IS 12 + IS mA ● Low temperature drift
● Optimized response time
Accuracy - Dynamic performance data ● Wide frequency bandwidth
● No insertion losses
ε Error @ IP N, TA = 25 °C @ ±15 V (±5 %) ±0.65 %
● High immunity to external
@ ±12 … 15 V (±5 %) ±0.90 %
interference
εL Linearity error < 0.15 %
● Current overload capability.
Typ Max
IO E Electrical offset current @ IP = 0, TA = 25 °C ±0.2 mA Applications
IO M Magnetic offset current 3) @ IP = 0 and specified RM,
after an overload of 3 × IP N ±0.3 mA ● AC variable speed drives and
IO T Temperature variation of IO −25 °C … +85 °C ±0.1 ±0.6 mA servo motor drives
−40 °C … −25 °C ±0.2 ±1.0 mA ● Static converters for DC motor
drives
tD 10 Delay time to 10 % of the final output value for IP N step < 500 ns
● Battery supplied applications
tD 90 Delay time to 90 % of the final output value for IP N step 4) <1 µs
● Uninterruptible Power Supplies
BW Frequency bandwidth (−1 dB) DC … 200 kHz
(UPS)
● Switched Mode Power Supplies
General data
(SMPS)
TA Ambient operating temperature −40 … +85 °C ● Power supplies for welding
TA st Ambient storage temperature −40 … +90 °C applications.
RS Resistance of secondary winding @ TA = 70 °C 80 Ω
Application domain
@ TA = 85 °C 85 Ω
m Mass 18 g ● Industrial.
Standards EN 50178: 1997
UL 508: 2010
Notes: 1) Measuring range limited to ±60 Amax
2)
Measuring range limited to ±55 Amax
3)
Result of the coercive field of the magnetic circuit
4)
For a di/dt = 200 A/µs.

N° 97.13.25.000.0 Page 1/3

6July2023/Version 19 LEM reserves the right to carry out modifications on its transducers, LEM International SA
in order to improve them. Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com
Current Transducer LA 55-P

Insulation coordination
Ud RMS voltage for AC insulation test, 50 Hz/1 min 2.5 kV
UNi Impulse withstand voltage 1.2/50 µs 5.7 kV
Min
dCp Creepage distance 5 mm
dCI Clearance 5 mm
CTI Comparative tracking index (group I) 600

Applications examples

According to EN 50178 and IEC 61010-1 standards and following conditions:

● Over voltage category OV 3


● Pollution degree PD2
● Non-uniform field

EN 50178 IEC 61010-1


dCp, dCI, UNi Rated insulation voltage Nominal voltage
Basic insulation 300 V 300 V
Reinforced insulation 150 V 150 V

Safety

This transducer must be used in limited-energy secondary circuits according to


IEC 61010-1.

This transducer must be used in electric/electronic equipment with respect to


applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.

Caution, risk of electrical shock

When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.

Page 2/3

6July2023/Version 19 LEM reserves the right to carry out modifications on its transducers, LEM International SA
in order to improve them. Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com
Dimensions LA 55-P (in mm)

dCl dCp

Connection
IP
IS RM

UC

UC

Mechanical characteristics Remarks


● General tolerance ±0.2 mm ● IS is positive when IP flows in the direction of the arrow.
● Primary through-hole 12.7 × 7 mm ● Temperature of the primary conductor should not exceed
● Fastening & connection of secondary 3 pins 90 °C.
0.6 × 0.7 mm ● Installation of the transducer must be done unless
● Recommended PCB hole ⌀ 1.2 mm otherwise specified on the datasheet, according to LEM
Transducer Generic Mounting Rules. Please refer to
LEM document N°ANE120504 available on our Web site:
https://www.lem.com/en/file/3137/download.
● Dynamic performances (di/dt and delay time) are best
with a single bar completely filling the primary hole.
● In order to achieve the best magnetic coupling, the
primary windings have to be wound over the top edge of
the device.
● This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.

Page 3/3

6July2023/Version 19 LEM reserves the right to carry out modifications on its transducers, LEM International SA
in order to improve them. Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com