0% found this document useful (0 votes)
31 views5 pages

Schneider Electric - PowerLogic-P5 - REL50402

The PowerLogic P5F30 is a protection and control relay designed for feeder applications with a voltage range of 48-250V DC and 100-230V AC. It features multiple protection functions, communication ports, and a robust environmental profile, ensuring compliance with various standards. The product is part of Schneider Electric's sustainability initiative, aiming for Net Zero status by 2050.

Uploaded by

Santosh Vardhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views5 pages

Schneider Electric - PowerLogic-P5 - REL50402

The PowerLogic P5F30 is a protection and control relay designed for feeder applications with a voltage range of 48-250V DC and 100-230V AC. It features multiple protection functions, communication ports, and a robust environmental profile, ensuring compliance with various standards. The product is part of Schneider Electric's sustainability initiative, aiming for Net Zero status by 2050.

Uploaded by

Santosh Vardhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Product datasheet

Specifications

PowerLogic P5F30 48-250V 3CT


1CSH 4VT 10DI-8DO
REL50402

notification_critical_stroke Discontinued

Main
Range of product PowerLogic P5

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Protection and control relay

Relay application Feeder - directional over current

product reference P5F30-AACB-HAAAA-BAEA

Mounting case size 30TE

Device mounting Flush

Mounting mode Withdrawable

power supply 48...250 V DC


100...230 V AC

measuring inputs : 1/5 A CT phase current 3


: CSH residual current 1
: VT voltage 4

Number of sensors 0 temperature sensor(s)


0 arc sensor(s)

number of Digital Inputs (DI) 10

number of analogue inputs 0

number of Digital Outputs (DO) 7 DO


1 watchdog

number of analogue outputs 0

communication ports USB port 2 front

communication protocols -

Cybersecurity Port hardening


Firmware signature
Client IP address filter
Secured communication with assciated tools
Security policy management
Role-based access control
Security log
LDAP
RADIUS based user authentication
IEC 62443-4-2 SL1

19-Mar-2025 1
protection functions Phase overcurrent 50/51
Directional phase overcurrent 67
Earth fault overcurrent 50N/51N
Directional earth fault 67N
Transient earth fault 67NI
Neutral admittance 21YN
Earth fault wattmetric 32N
Capacitor bank unbalance 51C
Broken conductor 46 I2/I1
Current unbalance 46 I2/I1
Cold load pick-up
Switch ON to fault (SOTF)
H2 detection
H5 detection
Breaker failure 50BF
Directional active underpower 37P
Fault locator 21FL
Recloser 79
Negative sequence overcurrent 46
Overvoltage 59
Undervoltage 27
Earth fault overvoltage 59N
Underfrequency 81/81N
Rate of change of frequency 81R
Synchro-check 25
Lockout relay 86
CT supervision 60
VT supervision 60
Programmable stages 99
Programmable logic
Programmable curve

measurement functions Current 3-phase


Current zero sequence
Current positive sequence
Current negative sequence
Current ratio of negative and positive
Phasor diagram of currents or voltages
Current 2nd, 15th harmonics with THD
Voltage 3-phase
Voltage residual
Voltage zero sequence
Voltage positive sequence
Voltage negative sequence
Frequency

control functions Switchgear control and monitoring


Programmable switchgear interlocking
Local/remote control

controllable switchgear devices 6 controlled + 2 monitored objects

number of setting groups 4

monitoring functions Trip circuit supervision 74


Circuit breaker monitoring
Relay self-monitoring

logs and records Event recording


Disturbance recording
Tripping context
Relay maintenance

Switchgear diagnosis type CT/VT supervision ANSI code: 60


Trip circuit supervision ANSI code: 74

Connections - terminals Screw (digital input/output)


Ring lugs (analog inputs and outputs)

Complementary
Software name ESetup Easergy Pro: virtual simulation test

Display type Colour LCD 480 x 272 pixels

Number of key 7 customizable

2 19-Mar-2025
Local signalling 4 x LED
10 x LED tri-colour programmable

Height 176 mm

Width 152 mm

Depth 219 mm

Net weight 3.5 kg

Environment
climatic withstand Exposure to cold conforming to IEC 60068-2-1
Exposure to dry heat conforming to IEC 60068-2-2
Exposure to damp heat in service conforming to IEC 60068-2-78
Exposure to damp heat in service conforming to IEC 60068-2-30
Temperature variation conforming to IEC 60068-2-14
Salt mist conforming to IEC 60068-2-52
Influence of corrosion/gas test 2 conforming to IEC 60068-2-60
Influence of corrosion/gas test 4 conforming to IEC 60068-2-60
Influence of corrosion/gas test 2 conforming to IEC 60721-3-3
Influence of corrosion/gas test 4 conforming to IEC 60721-3-3

Mechanical robustness Vibrations (level: class 2) conforming to IEC 60255-21-1


Vibrations conforming to GOST 17516.1
Vibrations conforming to IACS E10
Shocks (level: class 2) conforming to IEC 60255-21-2
Earthquakes (level: class 2) conforming to IEC 60255-21-3

Electromagnetic compatibility Emission tests class A conforming to CISPR 11


Emission tests class A conforming to CISPR 32
Emission tests conforming to IACS E10
EMC immunity class 4 conforming to IEC 61000-4-2
EMC immunity class 4 conforming to ANSI C37.90.3
EMC immunity level 3 conforming to IEC 61000-4-3
EMC immunity conforming to ANSI C37.90.2
EMC immunity conforming to GOST 32137
EMC immunity conforming to GOST 30804.4.3
EMC immunity conforming to IACS E10
EMC immunity level 5 conforming to IEC 61000-4-8
EMC immunity level 5 conforming to IEC 61000-4-9
EMC immunity level 5 conforming to IEC 61000-4-10
EMC immunity level 3 conforming to IEC 61000-4-6
EMC immunity level 3 conforming to IEC 61000-4-18
EMC immunity conforming to ANSI C37.90.1
EMC immunity conforming to IEC 61000-4-12
EMC immunity conforming to GOST 30804.4.12
EMC immunity level 4 conforming to IEC 61000-4-16
EMC immunity level 4 conforming to IEC 61000-4-4
EMC immunity level 4 conforming to IEC 61000-4-5

Ambient air temperature for -40…85 °C ( 16 h )


operation -40…70 °C ( 96 h )

Ambient air temperature for -40…85 °C


storage
IP degree of protection IP54 conforming to IEC 60529

maximum operating altitude 2000 m

Protective treatment Conformal coating conforming to IEC 60068-2-52:Kb/1


Conformal coating conforming to IEC 60068-2-60:Ke
Conformal coating conforming to IEC 60721-3-3:3C2

Relative humidity 0…93 % at 40 °C, without condensation, 56 days


93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 30.0 cm

Package 1 Width 30.0 cm

19-Mar-2025 3
Package 1 Length 35.0 cm

Package 1 Weight 4.5 kg

Contractual warranty
Warranty Up to 10 years extended warranty (Standard warranty 2 years. Please check with
your local SE representative for extended warranty availability and conditions)

4 19-Mar-2025
Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) 273

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Pro-active compliance (Product out of EU RoHS legal


EU RoHS Directive
scope)

REACh Regulation REACh Declaration

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

The product must be disposed on European Union


WEEE markets following specific waste collection and never end
up in rubbish bins

Take-back No

19-Mar-2025 5