0% found this document useful (0 votes)
78 views15 pages

MTD - 7000ip TRP - 22 - GVT 121500 001 04

The document provides technical specifications and features of the NEC 7000iP TRP, an all-indoor system designed for high reliability and performance in various environmental conditions. It includes details on power requirements, system parameters, and operational capabilities across different frequency bands. The document emphasizes the proprietary nature of the information and the possibility of changes in specifications without notice.

Uploaded by

klaus.csalmeida
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views15 pages

MTD - 7000ip TRP - 22 - GVT 121500 001 04

The document provides technical specifications and features of the NEC 7000iP TRP, an all-indoor system designed for high reliability and performance in various environmental conditions. It includes details on power requirements, system parameters, and operational capabilities across different frequency bands. The document emphasizes the proprietary nature of the information and the possibility of changes in specifications without notice.

Uploaded by

klaus.csalmeida
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

iPASOLINK VR series

7000iP TRP
for All-Indoor system

MTD-GVT-121500-001-04

NEC Corporation
MTD-GVT-121500-001-04 7000iP TRP

About This Document

This document describes the current version of NEC standard equipment. If there is any
conflict between this document and the System Description and/or the Compliance statement,
the latter will supersede this document. NEC Corporation shall not be liable for errors
contained herein.

The specifications or configuration contained in this document are subject to change without
notice due to NEC's continuing design effort.

This technical document contains proprietary information to NEC Corporation. Copy,


reproduction, modification, or distribution without prior written authorization of NEC
Corporation is strictly prohibited.

i
MTD-GVT-121500-001-04 7000iP TRP

Notice

© 2019 – 2022 by NEC Corporation

NEC is a registered trademark of NEC Corporation. All rights reserved. No part of this
document may be reproduced, distributed, stored in a retrieval system, or transmitted, in any
form or by any means, including electronic mechanical, photographic, or magnetic, without
prior written permission of NEC.

ii
MTD-GVT-121500-001-04 7000iP TRP

TABLE OF CONTENTS

1. INTRODUCTION ................................................................................................... 1
2. FEATURES ............................................................................................................ 2
2.1. Compact and high reliability TR UNITs........................................................................... 2
3. TR UNIT AND SYSTEM PERFORMANCE ................................................................. 3
3.1. General ........................................................................................................................ 3
3.2. System Parameters (CS= 28/29.65 MHz) ....................................................................... 4
3.3. System Parameters (CS= 40 MHz, High System Gain Mode) ........................................... 5
3.4. System Parameters (CS= 59.3 MHz) ............................................................................... 6
3.5. Frequency Plan ............................................................................................................. 7
3.6. BR CKT Loss .................................................................................................................. 8
CS 28/29.65MHz .............................................................................................................................8
CS 40MHz ........................................................................................................................................8
CS 59.3 MHz ....................................................................................................................................8
3.7. WG INTFC (DUP CKT) and BR CKT Block diagram............................................................ 9
WG INTFC and BR CKT for main antenna .......................................................................................9
WG INTFC and BR CKT for SD antenna ...........................................................................................9
3.8. Antenna configuration ................................................................................................ 10
Single polarized antenna ............................................................................................................. 10
Dual polarized antenna................................................................................................................ 10

iii
MTD-GVT-121500-001-04 7000iP TRP

1. INTRODUCTION
7000iP TRPs are renowned for their reliability and are trusted to provide market leading transmission
performance in the broadest range of environmental conditions across the planet.

Range of frequencies from 4 GHz to 11 GHz


Consists of BR CKT,TR UNIT

SD WG MAIN WG
INTFC INTFC
(SD DUP CKT) (DUP CKT)
MAI TX
SD RX N RX

BR CKT
TR UNIT

19 inch rack

MDP

Figure 1.1 OUTLINE (5 channels case, up to 10 channels available)

1
MTD-GVT-121500-001-04 7000iP TRP

2. FEATURES
2.1. Compact and high reliability TR UNITs
- High TX power (+40 dBm) support (6GHz).
- Improved TX power at high modulations
- High reliability and quality backed by excellent field-proven MTBF.
- Low power consumption: Incorporation of energy save integrated digital processing techniques and
adoption of high efficiency RF components.
- Power Saving Mode, which correlates with ATPC, achieves approx. 20% reduction of TR UNIT power
consumption.

Figure 2.1 TX Power Comparison between TR UNIT Series (6GHz)

2
MTD-GVT-121500-001-04 7000iP TRP

3. TR UNIT AND SYSTEM PERFORMANCE


3.1. General
(1) Power Requirements : -48 VDC (-40.5 to -57.0 VDC)
(2) Weight : Maximum 80 Kg 10 system
(DUP CKT, BR CKT, TR UNITs, MDP)

Item Specifications
Operation:–5 to +50°C (Workable: –10 to +55°C)
(Reference: 5 to +45°C by ETSI EN 300 019-1-3 Class 3.1E)
Environmental condition Humidity: 95% (at +50°C, No condensing)
Transportation 40 to +70°C (ETSI EN 300 019-1-2 Class 2.3)
Storage 25 to +55°C (ETSI EN 300 019-1-1 Class 1.2)
Power consumption Normal TX Power Type High TX Power Type
U4GHz 83 W (*1 -
6GHz 83 W (*1 173 W (*1
TR UNIT 75 W (NWA-A03117-0XX,NWA-A03118-0XX)
7GHz/8GHz -
83W (NWA-A03117-1XX,NWA-A03118-1XX) (*1
11GHz 72 W (*1 -
FAN-CV 5W 20 W
Mechanical Dimensions Normal TX Power Type High TX Power Type
210 x 64 x 240
U4GHz -
2.9kg
210 x 64 x 240 210 x 64 x 240
6GHz
2.9kg 3.2kg
TR UNIT 210 x 64 x 240
7GHz/8GHz 3.1kg(NWA-A03117-0XX,NWA-A03118-0XX) -
2.9kg(NWA-A03117-1XX,NWA-A03118-1XX)
210 x 64 x 240
11GHz -
2.9kg
FAN-CV 30 x 66 x 220
0.6kg
448(W) x 377(H) x 240(D) mm
U4GHz -
(5 system)
448(W) x 377(H) x 240(D) mm 448(W) x 443(H) x 240(D) mm
6GHz (5 system) (5 system)
448(W) x 557(H) x 240(D) mm
Rack Size 7GHz/8GHz -
(8 system)
448(W) x 443(H) x 240(D) mm
(5 system)
11GHz -
448(W) x 557(H) x 240(D) mm
(8 system)

EMC Conforms to ETSI EN 301 489-1,ETSI EN 301 489-4

Safety Conforms to ETSI EN 62368-1


*1 including SD unit and PS efficiency

3
MTD-GVT-121500-001-04 7000iP TRP

3.2. System Parameters (CS= 28/29.65 MHz)


U4 L6 7, 8
Normal
Normal High TX Power
Normal
TX Power TX Power NWA-A03117-[ ]xx
Frequency Band (GHz) TX Power Guaranteed
NWA-A03116-xx1 NWA-A03116-xx3 NWA-A03118-[ ]xx
NWA-A03115-xxx
NWA-A03116-xx2 NWA-A03116-xx4
[]:0 []:1
without with without With without With without with
-
option key option key option key option key option key option key option key option key

QPSK 33.0 33.0 33.0 33.0 40.0 40.0 33.0 33.0 33.0
16QAM 33.0 33.0 33.0 33.0 40.0 40.0 33.0 33.0 33.0
32QAM 33.0 33.0 33.0 33.0 40.0 40.0 33.0 33.0 33.0 Normal
Output Power
(dBm nominal) 64QAM 33.0 33.0 33.0 33.0 40.0 40.0 33.0 33.0 33.0 Tx Power
128QAM 33.0 33.0 33.0 33.0 40.0 40.0 32.0 33.0 33.0 ±1.0 dB
(Measured at TRP 256QAM 30.0 33.0 30.0 33.0 37.0 40.0 30.0 30.0 33.0
RF out port) High
512QAM 28.0 32.0 28.0 32.0 35.0 39.0 28.0 28.0 32.0 Tx Power
1024QAM 27.0 31.0 27.0 31.0 34.0 38.0 27.0 27.0 31.0 ±1.5 dB

2048QAM 27.0 31.0 27.0 31.0 34.0 38.0 27.0 27.0 31.0
Minimum Output Power
12 19 12
(dBm nominal)
Power Control (1dB step) Output Power to Minimum Output Power ± 1.0 dB
ATPC (1dB step) Output Power to Minimum Output Power -
Frequency Stability ±5ppm (at -5 to +40°C) ± 10 ppm
Threshold Level dBm measured at TRP RF in port BER = 10-6
(excluding BR CKT Loss) (Equivalent packet loss 0.1%, packet size 128 Bytes)
QPSK -88.5
16QAM -82.0
32QAM -79.0
64QAM -76.0
+3.0 dB
128QAM -73.0
256QAM -70.0
512QAM -67.0
1024QAM -63.5
2048QAM -60.0
BER = 10-3 Above value -1.0 dB
System Gain dB measured at TRP RF in port BER = 10-6
(excluding BR CKT Loss) (Equivalent packet loss 0.1%, packet size 128 Bytes)
QPSK 121.5 121.5 121.5 121.5 128.5 128.5 121.5 121.5 121.5
16QAM 115.0 115.0 115.0 115.0 122.0 122.0 115.0 115.0 115.0
32QAM 112.0 112.0 112.0 112.0 119.0 119.0 112.0 112.0 112.0
64QAM 109.0 109.0 109.0 109.0 116.0 116.0 109.0 109.0 109.0
128QAM 106.0 106.0 106.0 106.0 113.0 113.0 105.0 106.0 106.0 - 3.0 dB

256QAM 100.0 103.0 100.0 103.0 107.0 110.0 100.0 100.0 103.0
512QAM 95.0 99.0 95.0 99.0 102.0 106.0 95.0 95.0 99.0
1024QAM 90.5 94.5 90.5 94.5 97.5 101.5 90.5 90.5 94.5
2048QAM 87.0 91.0 87.0 91.0 94.0 98.0 87.0 87.0 91.0
BER = 10-3 Above value +1.0 dB
Maximum Input Level
-17 dBm for the BER less than 10-3 -
(excluding BR CKT Loss)

Less than 10-12 at RSL = -30 to


Residual BER
(threshold level (BER=10-6) + 5dB) dBm

Note 1): The above system parameters may be adjusted without prior notice
Note 2): New type NWA-A03117-1xx and NWA-A03118-1xx are the successor to NWA-A03117-0xx and NWA-A03118-0xx.

4
MTD-GVT-121500-001-04 7000iP TRP

3.3. System Parameters (CS= 40 MHz, High System Gain Mode)


U4 U6 11
Normal High
Normal Normal
TX Power TX Power
Frequency Band (GHz) TX Power TX Power Guaranteed
NWA-A03112-xx1 NWA-A03112-xx3
NWA-A03115-xxx NWA-A03111-xxx
NWA-A03112-xx2 NWA-A03112-xx4
without with without with without with without with
option key option key option key option key option key option key option key option key

QPSK 33.0 33.0 33.0 33.0 40.0 40.0 30.0 30.0


16QAM 33.0 33.0 33.0 33.0 40.0 40.0 30.0 30.0
32QAM 33.0 33.0 33.0 33.0 40.0 40.0 30.0 30.0 Normal
Output Power
(dBm nominal) 64QAM 33.0 33.0 33.0 33.0 40.0 40.0 30.0 30.0 Tx Power
128QAM 33.0 33.0 33.0 33.0 40.0 40.0 30.0 30.0 ±1.0 dB
(Measured at TRP RF 256QAM 30.0 33.0 30.0 33.0 37.0 40.0 27.0 30.0
out port) High
512QAM 28.0 32.0 28.0 32.0 35.0 39.0 25.0 29.0 Tx Power
1024QAM 27.0 31.0 27.0 31.0 34.0 38.0 24.0 28.0 ±1.5 dB

2048QAM 27.0 31.0 27.0 31.0 34.0 38.0 24.0 28.0


Minimum Output Power
12 19 9
(dBm nominal)
Power Control (1dB step) Output Power to Minimum Output Power ± 1.0 dB
ATPC (1dB step) Output Power to Minimum Output Power -
Frequency Stability ±5ppm (at -5 to +40°C) ± 10 ppm
Threshold Level dB measured at TRP RF in port BER = 10-6
(excluding BR CKT Loss) (Equivalent packet loss 0.1%, packet size 128 Bytes)
QPSK -88.5 -88.0
16QAM -82.0 -81.5
32QAM -79.0 -78.5
64QAM -76.0 -75.5
+3.0 dB
128QAM -73.0 -72.5
256QAM -69.5 -69.0
512QAM -66.5 -66.0
1024QAM -62.0 -61.5
2048QAM -58.5 -58.0
BER = 10-3 Above value -1.0 dB
System Gain dB measured at TRP RF in port BER = 10-6
(excluding BR CKT Loss) (Equivalent packet loss 0.1%, packet size 128 Bytes)
QPSK 121.5 121.5 121.5 121.5 128.5 128.5 118.0 118.0
16QAM 115.0 115.0 115.0 115.0 122.0 122.0 111.5 111.5
32QAM 112.0 112.0 112.0 112.0 119.0 119.0 108.5 108.5
64QAM 109.0 109.0 109.0 109.0 116.0 116.0 105.5 105.5
128QAM 106.0 106.0 106.0 106.0 113.0 113.0 102.5 102.5 - 3.0 dB

256QAM 99.5 102.5 99.5 102.5 106.5 109.5 96.0 99.0


512QAM 94.5 98.5 94.5 98.5 101.5 105.5 91.0 95.0
1024QAM 89.0 93.0 89.0 93.0 96.0 100.0 85.5 89.5
2048QAM 85.5 89.5 85.5 89.5 92.5 96.5 82.0 86.0
BER = 10-3 Above value +1.0 dB
Maximum Input Level
-17 dBm for the BER less than 10-3 -
(excluding BR CKT Loss)

Less than 10-12 at RSL = -30 to


Residual BER
(threshold level (BER=10-6) + 5dB) dBm

Note 1): The above system parameters may be adjusted without prior notice
Note 2): High Capacity Mode: Threshold Level form QPSK to 512QAM is +1.5dB from the value of upper table.

5
MTD-GVT-121500-001-04 7000iP TRP

3.4. System Parameters (CS= 59.3 MHz)


L6 7, 8 8
Normal High Normal Normal
TX Power TX Power TX Power TX Power
Frequency Band (GHz) NWA-A03116-xx1 NWA-A03116-xx3 NWA-A03117-1xx NWA- Guaranteed
NWA-A03116-xx2 NWA-A03116-xx4 NWA-A03118-1xx A03118-0xx

without with without with without with


-
option key option key option key option key option key option key

QPSK 33.0 33.0 40.0 40.0 33.0 33.0 32.0


16QAM 33.0 33.0 40.0 40.0 33.0 33.0 32.0
32QAM 33.0 33.0 40.0 40.0 33.0 33.0 32.0 Normal
Output Power
(dBm nominal) 64QAM 33.0 33.0 40.0 40.0 33.0 33.0 32.0 Tx Power
128QAM 33.0 33.0 40.0 40.0 33.0 33.0 31.0 ±1.0 dB
(Measured at TRP
256QAM 30.0 33.0 37.0 40.0 30.0 33.0 29.0 High
RF out port)
512QAM 28.0 32.0 35.0 39.0 28.0 32.0 27.0 Tx Power
±1.5 dB
1024QAM 27.0 31.0 34.0 38.0 27.0 31.0 26.0
2048QAM 27.0 31.0 34.0 38.0 27.0 31.0 26.0
Minimum Output Power
12 19 12
(dBm nominal)
Power Control (1dB step) Output Power to Minimum Output Power ± 1.0 dB
ATPC (1dB step) Output Power to Minimum Output Power -
Frequency Stability ±5ppm (at -5 to +40°C) ± 10 ppm
Threshold Level dB measured at TRP RF in port BER = 10-6
(excluding BR CKT Loss) (Equivalent packet loss 0.1%, packet size 128 Bytes)
QPSK -85.5
16QAM -79.0
32QAM -76.0
64QAM -73.0
+ 3.0 dB
128QAM -70.0
256QAM -67.0
512QAM -64.0
1024QAM -60.5
2048QAM -57.0
BER = 10-3 Above value -1.0 dB
System Gain dB measured at TRP RF in port BER = 10-6
(excluding BR CKT Loss) (Equivalent packet loss 0.1%, packet size 128 Bytes)
QPSK 118.5 118.5 125.5 125.5 118.5 118.5 117.5
16QAM 112.0 112.0 119.0 119.0 112.0 112.0 111.0
32QAM 109.0 109.0 116.0 116.0 109.0 109.0 108.0
64QAM 106.0 106.0 113.0 113.0 106.0 106.0 105.0
- 3.0 dB
128QAM 103.0 103.0 110.0 110.0 103.0 103.0 101.0
256QAM 97.0 100.0 104.0 107.0 97.0 100.0 96.0
512QAM 92.0 96.0 99.0 103.0 92.0 96.0 91.0
1024QAM 87.5 91.5 94.5 98.5 87.5 91.5 86.5
2048QAM 84.0 88.0 91.0 95.0 84.0 88.0 83.0
BER = 10-3 Above value +1.0 dB
Maximum Input Level
-17 dBm for the BER less than 10-3 -
(excluding BR CKT Loss)

Less than 10-12 at RSL = -30 to


Residual BER
(threshold level (BER=10-6) + 5dB) dBm

Note 1): The above system parameters may be adjusted without prior notice
Note 2): New type NWA-A03118-1xx is the successor to NWA-A03118-0xx.

6
MTD-GVT-121500-001-04 7000iP TRP

3.5. Frequency Plan


CS 28/29.65 MHz Plan
RF Frequency Freq. Range [MHz] RF TX/RX Channel ITU-R Doc. No.
Band [GHz] Spacing Spacing
Start Stop [MHz] [MHz]
U4 4400 5000 312 28 F.1099-5 ANNEX-3
L6 5925 6425 252.04 29.65 F.383-9
7 7125 7425 161 28 F.385-10
7425 7725 161 28 F.385-10
7125 7425 154 28 F.385-10 ANNEX-1
7425 7725 154 28 F.385-10 ANNEX-1
7110 7443 196 28 F.385-10 ANNEX-3
7443 7750 168 28 F.385-10 ANNEX-3
7425 7900 245 28 F.385-10 ANNEX-4
8 7725 8275 311.32 29.65 F.386-9 ANNEX-6
7900 8400 266 28 F.386-9 ANNEX-3

CS 40MHz Plan
RF Frequency Freq. Range [MHz] RF TX/RX Channel ITU-R Doc. No.
Band [GHz] Spacing Spacing
Start Stop [MHz] [MHz]
U4 4400 5000 300 40 F.1099-5 ANNEX-1
U6 6425 7125 340 40 F.384-11
11 10700 11700 490 40 F.387-12 2nd Option
10700 11700 530 40 F.387-12

CS 59.3 MHz Plan


RF Frequency Freq. Range [MHz] RF TX/RX Channel ITU-R Doc. No.
Band [GHz] Spacing Spacing ECC Doc. No.
Start Stop [MHz] [MHz]
L6 5925 6425 252.04 59.3 F.383-9
7 7425 7900 345 56 F.385-10 ANNEX-4
8 7725 8275 311.32 59.3 F.386-9 ANNEX-6
7900 8500 310 56 REC(02)06 ANNEX-3

7
MTD-GVT-121500-001-04 7000iP TRP

3.6. BR CKT Loss


The BR CKT Loss values include RF Cable, Low Loss Cable (1.4m or 1.5m) and DUP CKT loss. Loss of BEF used
to eliminate RF interference signal between Transmitter and Receiver is not included. BEF should be applied
in case of the channel allocation as follows, highest channel in lower half band and lowest channel in upper
half band are used in the same time.

CS 28/29.65MHz
U4GHz
BR CKT LOSS L6GHz 7GHz 8GHz Guaranteed
(*3)
1 system 6.1 6.4 6.8 7.2
2 system 6.8 6.8 7.0 7.6
3 system 7.3 7.3 7.5 8.0 + 1.0dB
Hybrid less type
4 system 7.8 7.8 7.8 8.5
(ACAP/ACCP common)
5 system 8.3 8.3 8.4 9.0
(dB)
6 system - 9.0 9.4 9.7
7 system - 9.7 10.0 10.3 + 2.0dB
8 system - 10.4 10.6 10.9
UDR-58 UDR-70
Waveguide interface UDR-48 UDR-70 UDR-84 UDR-84
(*2) (*2)

*1: The total of the loss value in one hop is shown.


*2: Optional Flange
*3: ACCP of U4GHz in not available.

CS 40MHz
BR CKT LOSS U4GHz U6GHz 11GHz Guaranteed
1 system 6.1 5.8 8.5
2 system 6.8 6.4 8.8
+ 1.0dB
3 system 7.3 6.9 9.1
Hybrid less type
4 system 7.8 7.4 9.5
(ACAP/ACCP common)
5 system 8.3 8.1 9.9
(dB)
6 system - 8.7 10.3
+ 2.0dB
7 system - 9.4 10.7
8 system - 10.0 11.1
Waveguide interface UDR-48 UDR-70 UDR-100

*1: The total of the loss value in one hop is shown.

CS 59.3 MHz
BR CKT LOSS L6GHz 8GHz Guaranteed
1 system 7.3 7.6
Hybrid less type
2 system 7.8 8.1
(ACAP/ACCP common) + 1.0dB
3 system 8.3 8.6
(dB)
4 system 8.8 9.1
UDR-58
Waveguide interface UDR-70 UDR-84
(*3)

*1: The total of the loss value in one hop is shown.

8
MTD-GVT-121500-001-04 7000iP TRP

3.7. WG INTFC (DUP CKT) and BR CKT Block diagram

WG INTFC and BR CKT for main antenna


 Combining with circulator type

Figure 5.4 WG INTFC/ BR CKT for Main antenna combining with circulator type

WG INTFC and BR CKT for SD antenna


 Combining with circulator type

Figure 5.5 WG INTFC/ BR CKT for SD antenna combining with circulator type

9
MTD-GVT-121500-001-04 7000iP TRP

3.8. Antenna configuration

Single polarized antenna

Single polarized
Single polarized two antennas
one antenna with SD system

Figure 5.6 Single polarized antenna configuration

Dual polarized antenna

Dual polarized Dual polarized


one antenna two antennas
with SD system

Figure 5.7 Dual polarized antenna configuration Suitable configuration

10
MTD-GVT-121500-001-04 7000iP TRP

11

You might also like