Three phase hybrid inverters 15 to 30 kW
ASW TH Series
Models:
ASW015K-TH
ASW020K-TH
ASW025K-TH
ASW29.9K-TH
ASW030K-TH
Optimal performance Safe and reliable User-friendly
• 4 MPPTs, up to 40 A input per • String-level current monitoring • Quick and easy-to-install with standard
MPPT • DC SPD Type II surge protection tools
• Up to 200 % PV array oversizing • IP66 rated design for indoor and • Cover design, choice from a delightful
• Up to 100 A charge / discharge outdoor use range of colours
current • Optimal battery voltage range, • Smart setup, commissioning and monitor-
• ShadeSol shadow management 120-800 V ing via Solplanet App
• Dynamic export power control • Intelligent operation modes and • Anti-theft design
smart battery management
• UPS-level switching time < 10 ms
solplanet.net @Solplanet
Technical Datasheet ASW015K-TH ASW020K-TH ASW025K-TH ASW29.9K-TH ASW030K-TH
Max. PV array power 30000 Wp 40000 Wp 50000 Wp 59800 Wp 60000 Wp
Max. input voltage 1000 V
MPP voltage range / rated input voltage 150 V to 950 V / 630 V
Min. input voltage / start voltage 95 V / 180 V
PV input
No. of independent MPPT trackers / strings per MPPT input 4/1 4/2
Max. input current / Max. power per MPP tracker 20 A / 15000 W 20 A / 15000 W 40 A / 25000 W 40 A / 25000 W 40 A / 25000 W
Max. short-circuit current per MPP tracker 25 A 50 A
Battery voltage range 120 V to 800 V
Max. charge power from PV and AC side 30000 W 40000 W 50000 W 59800 W 60000 W
Battery input
Max. charge power from AC side 15000 W 20000 W 25000 W 29900 W 30000 W
Max. discharge power 15000 W 20000 W 25000 W 29900 W 30000 W
Max. charge current / Max. discharge current 50 A 100 A
No. of independent battery inputs 1 2
Battery type LiFePO4
3/N/PE, 220 V / 380 V
Nominal AC voltage 3/N/PE, 230 V / 400 V
3/N/PE, 240 V / 415 V
AC input
Rated grid frequency 50 Hz / 60 Hz
Max. input power from grid 30000 W 40000 W 50000 W 50000 W 50000 W
Max. input current from grid 43.5 A 58.0 A 72.5 A 72.5 A 72.5 A
3/N/PE, 220 V / 380 V
Nominal AC voltage 3/N/PE, 230 V / 400 V
3/N/PE, 240 V / 415 V
AC voltage range 270 V to 480 V
Rated AC grid frequency 50 Hz / 60 Hz
AC grid frequency range 45~55 Hz / 55~65 Hz
Rated apparent power 15000 VA 20000 VA 25000 VA 29900 VA 30000 VA
Max. apparent power 15000 VA 20000 VA 25000 VA 29900 VA 30000 VA
AC output
Rated grid output current(@400V) 21.7 A 29.0 A 36.2 A 43.3 A 43.4 A
Max. grid output current 23.9 A 31.9 A 39.8 A 47.6 A 47.8 A
Power factor at rated power / adjustable range 1 / 0.8 leading to 0.8 lagging
Harmonics THDi (@ Nominal power) < 3 % (of nominal power)
3 / N / PE, 220 V / 380 V
Nominal AC voltage 3 / N / PE, 230 V / 400 V
3 / N / PE, 240 V / 415 V
Nominal output frequency 50 Hz/60 Hz
Rated apparent power 15000 VA 20000 VA 25000 VA 29900 VA 30000 VA
16500 VA 22000 VA 27500 VA 32890 VA 33000 VA
Rated current(@400V) 21.7 A 29.0 A 36.2 A 43.3 A 43.4 A
23.9 A 31.9 A 39.8 A 47.6 A 47.8 A
EPS output
5500 W 7333 W 9166 W 10963 W 11000 W
30000 VA 40000 VA 45000 VA 45000 VA 45000 VA
Max. switch time < 10 ms
Output THDv (@ Linear load) 2%
99.9 %
ciency
-
97.2 % / 98.0 % 97.9 % / 98.4 %
DC / AC surge protection (Type II, according to EN/IEC 61643-11)
Safety protection
Insulation resistance detection
PV string input reverse polarity protection
Battery input reverse polarity protection
Ground fault monitoring
Residual current monitoring unit
AC short circuit protection
Anti-islanding protection
Supported grid types TN-S, TN-C, TN-C-S, TT
Dimensions (W / H / D) 769 mm / 491 mm / 285 mm
Weight 52.0 kg 58.0 kg
General data
Colour Morandi blue / Earl red / Scandinavian grey
Operating temperature range -30 °C … +60 °C
Cooling concept Smart cooling
Degree of protection (as per IEC 60529) IP66
Max. relative humidity 100 %
Max. operating altitude 4000 m
User interface LED & APP
BMS interface CAN
Dongle: WiFi (2.4 GHz) / LAN (100 Mbps)
Communication interfaces
Features
Inverter: RS485 (ModBus RTU)
Digital output (dry contact) / No. of outputs
Digital input (dry contact) / No. of inputs
Integrated power control / export power control