Zoomlion SC200 Series Operation Manual of BWM 3S (Super Version) Construction Hoist
Zoomlion SC200 Series Operation Manual of BWM 3S (Super Version) Construction Hoist
We would like to extend our gratitude to you for your trust and support extended to the Zoomlion product, and
hope that things go all right with you.
I
Operation Manual of Construction Lifter
Note: All matters not covered by this Manual shall be dealt with in accordance with the provisions of the
Operation Manual of Construction Hoist.
III
Operation Manual of Construction Lifter
indicates a emergency hazard which, if not been prevented, will lead to death or serious
Danger injury
indicates a potential hazard which, if not been prevented, may lead to death or serious
Warning injury
indicates a potential hazard which, if not been prevented, may lead to minor or moderate
Note injury
indicates a risk which is not related to personal injury (such as property damage)
Caution
IV
Operation Manual of Construction Lifter
Table of Contents
Words for User .......................................................................................................................................................... I
Safety Notices for Construction Hoist ..................................................................................................................... II
Instructions on Safety Information ........................................................................................................................ IV
V
Operation Manual of Construction Lifter
VI
Operation Manual of Construction Lifter
VII
Operation Manual of Construction Lifter
8
Operation Manual of Construction Lifter
Technical Parameters
Technical Parameters
1. Schematic Diagram for Overall Structure of Ordinary-type BWM-3S(SC200/200) Construction Hoist ............. 2
2. List of Technical Parameters of Ordinary-type BWM-3S(super version) Construction
Hoist…………………….4
3.List of Technical Parameters of Energy-saving Type BWM-3S(super version) Construction
Hoist………………5
Technical Parameters
Technical Parameters
Limit stopper
Electrically-driven jib
Mast
Drive system
Cable support
Cage
Scaffold
Hoist foundation
Technical Parameters
Mast
Limit stopper
Drive system
Jib
Cage
Cable trolley
Mast tie
Cable guiding device
Hoist foundation
Power box
Technical Parameters
3. List of Technical Parameters of Energy-saving Type BWM-3S (Super
Version) Construction Hoist
Model
SC200EB SC200/200EB Remarks
Parameter
2000 or 24
Rated load (kg) 2×2000 or 24 persons
persons
Rated erection load
1000 2×1000
(kg)
Rated speed
0~40
(m/min)
Maximum lifting
500
height (m)
Dimension of cage
(length × width × 3.2×1.5×2.5(m)
height)
Supply voltage (V) 380±5% 50/60Hz
Power of motor
2×13 2×2×13 JC25%
(kW)
Rated operating
2×27 2×2×27
current (A)
Supply power (kW) 35 2×35
Weight (kg) Thickness(mm)
145 4.5
Standard section
160 6.0
weight (kg)
180 8.0
195 10.0
Including the
Dead weight of cage weight of drive
1900 2×1900
(kg) system and
control system
Model of safety
SAJ40-1.2 SAJ40-1.2
protector
②
Operation and Safety
(1) Carry out the specified routine inspection and lubrication in accordance with the requirements of the
Maintenance Manual;
(2) Inspect the position of baffle plate and stopper of every limit switch on mast section, and make sure that they
are sensitive, reliable, safe and effective;
(3) Inspect whether the electro-mechanic interlock device of base enclosure and cage door is in good conditions;
(4) Stop the cage in the ground station, and open and close the external base enclosure door, cage door and roof
respectively. Check if these components are in good conditions and the cage can’t be started when checking the
cage;
(5) Move the cage upwards and stop it at the height of about 3m. At this time, the incoming door and external base
enclosure shall be locked up and can’t be opened;
(6) Inspect the functions of terminal stopping switches, up/down deceleration limit switch and power limit switch:
if the upper terminal stopping switch, lower terminal stopping switch or power limit switch is cut off, the cage
shall be unable to be started; if the deceleration limit switch is cut off, the cage shall be in the deceleration state;
(7) As for the construction hoist equipped with counterweight, it is also necessary to inspect the function of rope
limit switch on eccentric rope on the cage roof. If this switch is cut off, the cage shall be unable to be started;
(8) Ensure that there is no obstacle in passages of cage and counterweight, and carry out monitoring from time to
time;
(9) The installation jib on cage shall be removed, and it is prohibited to get the installation job loaded;
(10) Under the installation conditions, the cage roof operation shall be adopted;
(11) Before starting the cage, be sure to remind all personnel; in the course of operation, if any abnormal situation
is found, please immediately press down the emergency stop button;
(12) If the hoist is involved in any abnormal situation, be sure to inform the relevant repair personnel in time, and
it is prohibited to get the hoist repaired by any person other than repair personnel;
(13) As for inspection or repair of circuit, please cut off the main power supply, wait for 10 minutes and then
carry out inspection or repair;
(14) Neither person nor article in cage may lean against the cage door;
(15) After the construction hoist is exposed to heavy rain or strong typhoon, it is key components shall be
inspected by professional technical personnel;
(16) Carry out the inspection, maintenance and drop test on a regular basis in accordance with the requirements;
Warning
(1) When there is any person working in prohibited area of base frame and base enclosure, mast, mast tie
(3) Properly close all doors, including the incoming door, outgoing door, roof door and external base enclosure,
and ensure that the incoming door is properly locked.
Floor calibration
Note
The manual release of brake shall be carried out intermittently, so as to ensure that the cage will only slide
for a relatively short distance every time and the sliding speed will not exceed the normal speed of cage.
Once the speed limit is exceeded, the overspeed safety device will act, so as to stop the cage. In such case,
the cage may be slid down only after the overspeed safety device is reset. Whenever the cage has slid down
for 20m, stop it for 1 minute, so as to get the motor brake cooled down. When working on cage roof, please
pay attention to safety.
braking torque), the cage slides down to the position which causes the action of power limit switch, and thus the
three-phase power supply is cut off and the cage can’t be electrically moved upwards, then, please switch off the
arm rod of limit switch for a certain distance, so as to reset the limit switch and move the cage upwards.
Thereafter, re-adjust the distance of arm rod of limit switch, so as to ensure that it can effectively contact with the
stopper.
③
Electrical Control System
1. Composition of Electrical Control System .......................................................................................................... 3
1.1 Power Supply from Construction Site……………………………………………………………………...3
1.2 Electrical Control Cabinet …………………………………………………………………………………3
1.3 Operating Console………………………………………………………………………………………….4
1.4 Drive System……………………………………………………………………………………………….4
1.5 Safety Protection & Limit System………………………………………………………………………….4
1.6 Identity Recognition System……………………………………………………………………………….4
1.7 Encoder …………………………………………………………………………………………………….6
2 Electrical Installation…………………………………………………………………………………………7
Electrical Control
2.1 Connection between Power Supply from Construction Site and Cable of Hoist …………………………7
System
2.2 Connection of cable from Power Box to Cage ……………………………………………………………7
2.3 Grounding of Hoist ………………………………………………………………………………………..8
2.4 Connection of Up/Down Moving Mechanism, Resistance Cabinet and Anti-hoisting Limit……………..8
2.5 Installation of Sensing Pin and Overload Protector ……………………………………………………….8
2.6 Trial Operation …………………………………………………………………………………………...9
3 Operation of Electrical System ……………………………………………………………………………..10
3.1 Preparatory Work…………………………………………………………………………………………10
3.2 Manual/Automatic Operation …………………………………………………………………………….12
3.3 Cage Roof Operation ……………………………………………………………………………………..15
3.4 Drop Test …………………………………………………………………………………………………16
3.5 Floor Call …………………………………………………………………………………………………17
3.6 Maintenance ……………………………………………………………………………………………...20
4 Information Display Equipment……………………………………………………………………………21
4.1 Display Panel……………………………………………………………………………………………..21
4.2 Display of Frequency Converter………………………………………………………………………….24
4.3 Display of HLC Controller……………………………………………………………………………….26
5 Intelligent Control System………………………………………………………………………………….28
5.1 Functions of Intelligent Control System………………………………………………………………….28
5.2 Structure of Intelligent Control System…………………………………………………………………..28
5.3 Installation and Notices for Intelligent Control System ………………………………………………….29
Electrical Control
located in it. The electrical control cabinet is mainly composed of the following parts:
System
(1) AC limit switch (power switch of hoist);
(2) Transformer of control circuit which supplies the control voltage;
(3) Up/down control system.
In the figure below, the electrical control cabinet of BWM-3S (super version) construction hoist is indicated:
Frequency Circuit Intermediate Brake
converter breaker relay contactor
Transformer Power suply Main
for switch contactor
Rectification bridge
terminal block
Connecting
Figure 1.2-1 Electrical Control Cabinet of BWM-3S (Super Version) Construction Hoist
Electrical Control
A. Carry out the in-cage and
out-cage operation
System
B. Carry out the authorization Insertion of card: Long buzz
Management After the card is inserted, [F]
for operation card and Pulling out of card: No sound
card will always be displayed
maintenance card reminder
C. Carry out the setting for
automatic floor alignment
Insertion of card (or success of When the card is inserted, the
authorized): One short buzz serial number of such card in
Operation Carry out the in-cage
Pulling out of card (or failure operating console will be
card operation
of authorization): Two short displayed for 3 seconds. [1]
buzzes -[8] is for operation card
Insertion of card (or success of When the card is inserted, the
A. Carry out the in-cage and
authorized): One short buzz serial number of such card in
Maintenance out-cage operation
Pulling out of card (or failure operating console will be
card B. Carry out the setting for
of authorization): Two short displayed for 3 seconds [A1]
automatic floor alignment -[A8] is for maintenance card
buzzes
Insertion: The intermittent
After the card is inserted, [E]
Invalid card short buzz will be given
will be displayed for 3 seconds
continuously
(1) Authorization - Insert the management card into the IC card groove firstly, wait until the identity recognition
lamp comes on, and then pull out the management card and insert the operation card or maintenance card within
10 seconds. If the identity recognition lamp comes on, then the authorization is successfully completed.
(2) Operation without card - 1. When the identity is confirmed as invalid or the card is not inserted, the hoist can
only be moved downwards; 2. When the identity recognition fails during the operation, under the condition that
the power supply is not cut off, one work cycle will be completed.
(3) Shielding from identity recognition - Under special circumstance (e.g., all the IC cards are lost or the identity
recognition module fails), the identity recognition function can be shielded via APP, so as to use the hoist
temporarily. After the identity recognition function is shielded, the identity recognition lamp on display screen of
Electrical Control System BWM-3S 3-5
Operation Manual of Construction Lifter
1.7 Encoder
The encoder will collect the height information of hoist during operation by converting the angular displacement
of gear into electrical signal, and then send the height information to the frequency converter. The frequency
converter will control the up moving, down moving and stop of hoist on the basis of the floor alignment data, so
as to enable the accurate floor alignment by hoist.
Note
The connecting wires of encoder are A, B, Z, 0V and 24V. When connecting the encoder to frequency
converter, please carry out the connection in accordance with the wire code. Be sure not to confuse the
Electrical Control
wires A/B/Z with wire 24V; otherwise the encoder will be damaged.
System
2 Electrical Installation
2.1 Connection between Power Supply from Construction Site and Cable of Hoist
Connect the construction site cable to the screw-type connecting terminal in power box (Before the connection,
please ensure that the power supply is cut off, and the plastic-casing circuit breaker is opened).
Electrical Control
2.2 Connection of cable from Power Box to Cage
System
(1) Use the construction site cable (≥25mm2) to connect the power box of construction site with the power box on
base frame and base enclosure;
(2) Connect one end of the main cable to the power box on base frame and base enclosure, and connect the other
end to the terminal in electrical control cabinet in cage via the cable support.
It is necessary to point out that, the installation method of power cable of construction hoist and the cable guide
device adopted falls into cable drum type and cable trolley type.
①If the cable drum type is adopted, please directly place the cable into cable drum in accordance with the
installation method of cable guide device;
② If the cable trolley type is adopted, there are the following two situations:
• If one cable is used for supply for power, please directly implement the above step (2);
• If two cables with different sectional area are used for supply of power (The cable with large sectional area
is fixed on mast and is referred to as fixed cable, and the cable with small sectional area will move together with
the cable trolley and is referred to as accompanying cable), please implement the above step (2) on the
accompanying cable.
(3) The main cable contains three phase wires, one zero wire (N) and one protective wire (ground wire). The
protective wire is greenish yellow. Since the damage of power cable may cause serious accident, the power cable
shall be the cable with mechanical damage resistance, and shall be protected by appropriate method (e.g., cable
drum with roller, cable chute, bend radius connection, or cable sheath), so as to prevent the insulation layer from
being damaged.
Note
When connecting the main cable of hoist, please maintain the AC limit switch in the state (off) as indicated
in the figure.
Off State
exceed 4Ω, and the insulation resistance against ground of motors and electrical elements as measured with 500V
megohm meter shall be no less than 1MΩ.
System
2.4 Connection of Up/Down Moving Mechanism, Resistance Cabinet and Anti-hoisting Limit
(1) Connect the three-phase asynchronous motor (M) to the connecting terminal (U/V/W) for motor in accordance
with the requirements of drawings;
(2) Connect the brake (YB+, YB-) cable to the terminal block;
(3) Connect the resistance cable (PA/PB) to the terminal block;
(4) Connect the anti-hoisting limit.
(5) Install the limit switch on base frame and base enclosure, and connect the cable to power box.
Communication
line 485
Electrical Control
Before being used, the overload protector shall be cleared and reset. Before the product is delivered from factory,
it has been cleared. If it is found that the displayed value is not identical with the actual value, please carry out the
System
clearing on site. The clearing methods include:
(1) Coarse adjustment: Press down and hold the coarse adjustment key for 3 seconds, and the clearing
operation will be completed after a beep is heard
(2) Loaded fine adjustment:
• Press down and hold the coarse adjustment key until a beep is heard;
• Place the load *t;
• Press down both the coarse adjustment key and fine adjustment key, and then press the coarse adjustment
key for changing the figure to *t, and finally press the fine adjustment key for confirmation.
Power indicating
lamp
Note
Under any of the following circumstances, please immediately turn off the AC limit switch:
3-10 BWM-3S Electrical Control System
Operation Manual of Construction Lifter
1) Any emergency is encountered and the electrical control system fails, (e.g., the contacts of contactor are
burnt and stuck to each other and the emergency stop button on operating console fails);
2) The operator leaves the cab for any reason.
(2) Start Operation
The start button (green) is located on the panel of operating console. It is a double-function button, which means
that it can be used to start the cage and sound the electrical bell. Whenever the contactor of power box is engaged
and the lighting circuit breaker is closed, the electrical bell can be sounded. In addition, only after the cage doors
are closed, can the system be started by pressing down this button (The master contractor of main circuit is
engaged). If no such reaction appears after the start button is pressed down, it means that the start operation fails.
If the start operation fails, the hoist can’t be moved up or down.
(3) Emergency Stop
The emergency stop button is located on the panel of operating console, power box and cage roof operation box
respectively, and is a red self-locked mushroom-shaped button. Its role is to disengage the master contractor of
main circuit, so as to realize the emergency stop of various mechanisms.
Note
Electrical Control
In case during the operation, any emergency is encountered and there is no time for stopping the hoist in
System
accordance with normal procedure or the hoist is out of control, please immediately press down the
emergency stop button! Under the circumstance other than emergency, it is not advised to use the
emergency stop button for normal stop; otherwise great impact may occur.
Identity recognition
Insert the
IC card
(2) Inspect whether the limit protection switches are properly adjusted (For adjustment method, please refer to the
relevant sections of use instruction for host processor); after every limit protection switch acts, whether the
electrical control system implements the corresponding protective function (Please refer to the above contents). If
any trouble is found, please immediately stop the hoist and carry out inspection and repair; before the trouble or
hidden danger is eliminated, don’t put the hoist into operation again.
(3) Please carry out the operation only after making sure that all items inspected are qualified; otherwise personal
injury accident may occur.
2) At the position of Floor 1, press the keys “1”and “Confirm”, so as to calibrate Floor 1;
3) Operate the rocker bar so as to manually move the hoist up to Floor 2, and the press the keys “2” and
“Confirm”, so as to calibrate Floor 2;
4) Calibrate every floor in this way, until the hoist reaches the highest floor which can be calibrated;
5) Press the key “Cancel” so as to complete the calibration. Thereafter, the hoist can go to the desired floor by
operation of keys on keyboard;
Electrical Control
6) If it is necessary to calibrate any new floor after the rail is extended, please repeat the operation in (1) and carry
out calibration on the basis of the original calibration result. For example, if Floor 7 has been calibrated, just carry
System
out calibration from Floor 8;
7) If a floor which has been calibrated is not aligned accurately, just re-calibrate such floor at the correct position
of such floor, and it is unnecessary to re-calibrate all floors.
Note
Before calibrating the first floor of newly-installed hoist, please confirm that the number of floors which
have been calibrated is 0. If the figure displayed is not 0, please carry out the clearing operation. Please
refer to the contents of “(3) Clearing of Floor Information” on next page.
are 10 floors, and you press the keys “8” and “Confirm”, the keys “9” and “Confirm”, the keys “3” and “Confirm”
System
and the keys “2” and “Confirm” and press the key “Operate”, then the hoist will, in accordance with the principle
“up first and from near to far”, go to Floor —> Floor 9 —> Floor 3 —> Floor 2 successively.
(3) Upper/lower floor operation: The up/down moving of hoist can be realized by pressing the key “Upper Floor”
or “Lower Floor” rather than entering any number. For example, if you want to go to Floor 2 when the hoist is at
Floor 3, just press the keys “Lower Floor”, “Confirm” and “Operate” successively, so as to get to Floor 2
smoothly.
(3) Clearing of Floor Information
Note
For the sake of safety, the floor information in every hoist has been cleared before the hoist is delivered.
Under any of the following circumstances, please carry out the clearing operation for floor information;
otherwise accident may occur!
(1) When the new hoist is installed
(2) Before the equipment is dismantled
(3) Before the hoist is used in a new construction site
(4) When the rail of hoist is dismantled for reducing the number of floors
(5) When the encoder is in trouble and thus is replaced or re-installed.
Clearing Method:
Method 1: Insert the maintenance card or management card, and, after the identity is recognized, directly press
down and hold the key “Cancel” for more than 3 seconds. If the number of floor calibrated flashes at the position
on operating console for displaying the number of current floor, it means that the system enters into the clearing
state. Thereafter, press the key “Confirm” so as to complete the clearing operation. Note: If you want to cancel the
clearing operation after entering into the clearing state, just press the key “Cancel” once again.
Method 2: Get the parameter B8.10 changed to 0 by professional maintenance personnel via the panel of
frequency converter; when the automatic floor alignment function is to be used again, set the floor information in
accordance with the floor calibration procedure.
3.2.3 Changeover between Manual/Automatic Mode
On the hoist of this version, the control system is of manual/automatic type, and the manual operation mode and
automatic floor alignment mode can be changed over freely via control lever or keyboard. Even if an operation
mode fails, the use of another operation mode is not affected.
Electrical Control
System
Target floor
of operating console comes on, which means that the identity with maintenance authority is recognized;
(2) Firstly turn the changeover button on cage roof operation box to the position of cage roof operation, wait until
the cage roof operation lamp on display panel comes on, and then carry out the up/down moving operation. Under
emergency circumstances, just press down the emergency stop button on cage roof operation box so as to cut off
the power supply. When carrying out the cage roof operation, the control lever in cage for controlling the up/down
moving can’t control the action of hoist;
(3) The ordinary operation card has no authority for carrying out cage roof operation.
Note
If before the system is started, the selection knob of cage roof operation box is at the position of “cage roof
operation mode”, then no operation can be carried out in cage, and the “cage roof operation” indicating
lamp will flash.
(1) If it is necessary to carry out in-cage operation, just turn the selection knob on cage roof operation box to the
position of “in-cage operation mode”;
(2) If it is necessary to carry out cage roof operation, firstly turn the selection knob on cage roof operation box to
the position of “in-cage operation mode”, and then turn it to the position “cage roof operation mode”, so as to
enable the cage roof operation.
Note
(1) If the drop test box is connected in cage roof mode, the system will give the warning, and E40 trouble will be
displayed in display area of trouble code. In such case, it is necessary to set the cage roof operation box at in-cage
mode, energize the system for eliminating the warning, and then connect the drop test box.
(2) If in the course of drop test, the hoist is started or moved up or down in cage or on cage roof, the system will
give the warning, and E41 trouble will be displayed in display area of trouble code. In such case, it is necessary to
energize the system for eliminating the warning, and then carry out the drop test.
(3) Since the drop test is very dangerous, it is necessary to properly carry out preparatory works, and get the test
carried out by professional maintenance personnel.
Electrical Control
Step 1: Enter into the self-learning state: The following two methods are available for entering into the
System
self-learning state:
Method 1 (recommended): Enter the password 0362951 via the keyboard.
Method 2: Insert the needle in small hole on lower portion of white receiving box, and then press down and
hold the key for about 3 seconds (If there is a button on operating console, you may also press down and hold
such button, so as to enter into the self-learning state)
After the system enters into the self-learning state, the display area for call on operating console will display “--”.
Figure 3.5-3 Address Code and floor Number of Floor Call Sub-processor
Note
If the code of host processor marked on callmaker is lost or it is necessary to temporarily change the
address code and floor number, just disassemble the callmaker for examination or change. In the figure
below, the disassembled callmaker is indicated.
Address code
Floor code (Floor
11 is indicated in
the figure)
Electrical Control
System
3.6 Maintenance
The construction hoist shall be maintained on a regular basis by professional maintenance personnel (For details,
please refer to the Operation manual of Construction Hoist).
It is necessary to point out that, in the course of maintenance, maybe it is necessary to operate the hoist on cage
roof via the cage roof operation box. In order to maintain the safe and effective operation, the intelligent version
hoist has been provided a series of protective measures. Therefore, the maintenance of the hoist shall be carried
out in accordance with the following steps:
(1) Insert the management card or maintenance card, and wait until the identity recognition lamp on display
screen of operating console comes on, which means that the identity with maintenance authority is recognized;
(2) Carry out the corresponding maintenance items;
(3) After the maintenance is completed, pull out the maintenance card. The completed maintenance items can
be checked and confirmed via mobile phone APP, so as to change the state [to be maintained] to [maintained].
Equipment
No.: Confirm
Maintenance
Card No.:
Date of
Maintenance:
Construction Site:
Reminder for Maintenance: After the rail is extended, please carry out
inspection and confirmation in accordance with the relevant
Details of Maintenance:
Floor call
Load
Indicating
lamp
Electrical Control
System
A. Normal Display State
Ordinary
trouble code
Trouble code
of frequency
converter
hoist changes.
Another function of this digital tube is to display frequency-converter trouble code. For details, please refer to
Table 2-1.
(3) Target floor
The number of up to 4 target floors can be entered.
(4) Load display
This digital tube has many functions. It can not only display the load of construction hoist, but also display the
trouble code in case of occurrence of any trouble.
4.1.2 Indicating Lamps
From left to right, the indicating lamps are: skylight limit, bi-parting door limit, vertical sliding door limit, floor
calibration setting, cage roof operation, upper/lower limit, and IC card identity recognition. The details are given
in the figure below.
Electrical Control
System
[Or the communication of frequency converter fails, the encoder is in trouble, or the floor for
learning has been passed]
(2) Battery power mode: If the external power supply is cut off or the 9V DC power supply is cut off, the
operating console will enter into the battery power mode.
C. Power-saving Mode (5 minutes) D. Deep Power-saving Mode (25 minutes) E. Sleeping State
[The floor call and remote communication functions are available]
[Only the floor call function is available]
[All functions are deactivated]
(3) Wake-up:
Method 1- Commercial power supply: After the commercial power supply is connected, the operating
console will change from battery power mode to commercial power mode
Method 2 - Insertion or pulling of IC card: In the battery power mode, after the IC card is inserted or pulled
out, the equipment will enter into the power-saving mode, with the duration being 5 minutes.
Electrical Control
4.1.4 Inquiry about Input from Keyboard
System
If you want to inquire about the terminal number of control system, the number of SIM card or the version
number of programme, just press down the corresponding digit key on keyboard for 3 seconds, and then the
relevant information will be displayed on display panel. For the contents to be inquired, please refer to the table
below:
Table 4.1-1 Inquiry about Input from Keyboard
3 CPU-ID
Increase key
Programming key Confirmation key
Function reserved
Hz Frequency unit
A Current unit
V Voltage unit
&Percentage
Electrical Control
Return Saving
System
Enter
Setting of parameter value Serial No. of
next parameter
2) Trouble display
Trouble indication Trouble class Trouble code
Note
Limit prohibited means when the hoist is not effectively started, there is no valid input on DI10 of
frequency converter (there is no valid output on limit output point of HLC), and after the hoist is normally
started, the display “STOP3” will disappear.
(3) <INV> means that the HLC controller is communicating with frequency converter [reserved for upgrading];
System
In addition, the HLC controller is also equipped with self-inspection and protection lamps;
(4) If the <self-inspection> lamp comes on, it means that the self-inspection circuit of HLC controller is working;
(5) The <protection> lamp will come on when there is normal external command input.
When the input signal meets the logic requirements, the corresponding indicating lamp will come on, and the
HLC will send the corresponding control command, so as to operate the construction hoist.
Figure 4.2-1 Signal Lamps of Logic Controller of BWM-3S (Super Version) Construction Hoist
Note
The HLC controller has the sound warning function, and the warning will be given when some troubles
occur!
Electrical Control
System
As indicated in the figure, the structure of control system is divided into the following 5 parts.
System
(1) The HLC controller is the electrical control unit of hoist, and is installed in electrical control cabinet together
with frequency converter and overload protector;
(2) The operating console can receive the command entered via keyboard and control lever, and has the functions
such as state display and identity recognition;
(3) The floor call receiver is connected into the operating console for receiving the call data from floor
sub-processor;
(4) The GPS antenna is also connected into the operating console for receiving the GPS positioning data;
(5) The remote server will carry out the wireless communication with control system, so as to realize the remote
monitoring on information about operation state, warning and maintenance, and will send the information
monitored to the mobile phone APP.
phone APP
Remote
Mobile
server
Frequency
converter
Overload
protector
HLC
controller
Electrical Control
Operating Electrical
System
console control cabinet
Note
The inspection and wiring of frequency converter may be carried out only after the external power supply
has been cut off for 3 minutes; otherwise the residual voltage in frequency converter may cause electrical
shock!
Table 5.4-1 List of Trouble Codes of HLC
E35 The zero position of main command switch fails (The handle has neither zero
position signal nor positive/negative rotation command)
E36 The zero position and command of main command switch are abnormal (The handle
zero position signal and positive or negative rotation command appears
simultaneously)
E37 The cage roof operation command is abnormal (The up and down moving input
points are closed simultaneously)
E38 The drop operation command is abnormal (The up moving and drop input points are
closed simultaneously)
E39 The drop selection command is abnormal (The up moving or drop command
appears when no drop is selected)
E40 The cage roof and drop selection command is abnormal (The cage roof and drop are
selected simultaneously)
E41 The drop state is abnormal (There is in-cage and cage roof operation signal in drop
mode)
E42 Trouble in frequency converter (The frequency converter trouble input points are
disconnected)
Electrical Control
E43 The overload protector is short-connected
System
5.5 Emergency Use in Case of Trouble in Intelligent Control System
When the integrated intelligent control system is in any of the following troubles, in order to prevent the impact
on operation, the hoist can be used under emergency state as follows:
(1) If the automatic floor alignment mode or the manual mode is in trouble, another mode may be used to operate
the hoist, and the repair personnel shall be informed to carry out repair in time.
(2) If the identity recognition function is in trouble, the management personnel with relevant authority may via the
mobile phone APP, temporarily deactivate the identity recognition function, or the Service Department of
Zoomlion may temporarily deactivate the identity recognition function. Please contact the Service Department of
Zoomlion as soon as possible.
(3) If the wireless network is in trouble, the equipment will enter into the counter-down locking state (240
working hours). In this period, the equipment can still be used, but after the accumulative operation time reaches
240 hours, the system will not work. Therefore, please contact the Service Department of Zoomlion as soon as
possible.
(4) If the communication among internal modules of the system is in trouble, the automatic floor alignment
function will not be available, but the equipment can be operated manually. The system and mobile phone APP
will give the trouble reminder, and the equipment will enter into the accumulative operation time limit mode.
During this period, the equipment can be used, but if the accumulated operation times exceed the limit, the system
will not work. Therefore, please contact the Service Department of Zoomlion as soon as possible.
④
Management Measures
1 Management Measures for IC Card of BWM-3 Construction Lifte .................................................................... 2
1.1 General Provisions ..................................................................................................................................... 2
1.2 Issuance, Use and Replacement of SIM Card .............................................................................................. 2
1.3Other Provisions ......................................................................................................................................... 3
1.4 Supplementary Provisions ......................................................................................................................... 3
2 Management Measures for IC Card of BWM-3 Construction Hoist ................................................................... 4
2.1 General Provisions ..................................................................................................................................... 4
2.2 Issuance, Use and Replacement of IC Card ............................................................................................. 4
2.3 Other Provisions .......................................................................................................................................... 5
2.4 Supplementary Provisions ......................................................................................................................... 5
3 Management Measures for BWM-3 APP Account Number ............................................................................. 6
3.1 General Provisions ..................................................................................................................................... 6
3.2 Application, Use and Replacement of APP Account Number..................................................................... 6
3.3 Other Provisions .......................................................................................................................................... 6
Management Measures
3.4 Supplementary Provisions ......................................................................................................................... 6
Management Measures
As for intelligent version and super version hoists, since the intelligent degree is relatively high, it is necessary to
normalize the management on SIM card, IC card and APP account number used.
that the equipment can be put into use in time. If such number is incorrect, the customer shall have the right to
require the service personnel of the Company to make correction, and the Company will complete the correction
within 5 working days.
(3) The customer shall, after the date on which the host processor is received, apply with the Company for starting
procedure via the business personnel of the Company, and the Company will complete the operation within 3
working days after receiving the application.
(4) Role of SIM card: To automatically monitor the operating state of equipment, and collect the trouble data, so
as to facilitate the realization of functions such as management on start and stop of equipment as well as
management on attendance of personnel. For details, see Annex 1. The customer may, on the basis of the authority,
apply with the Company for dealing with the relevant business.
(5) If being replaced owing to upgrading of HLC or trouble, the SIM card can’t be used again; the service
personnel shall report to the 400 call center, and the call center shall be responsible for discarding such SIM card;
if the SIM card is replaced owing to trouble, the corresponding information shall be reported by service personnel
to the 400 call center, and the call center shall be responsible for recording such information for SIM card.
(6) When going through the formalities for replacement of card, the customer shall, by virtue of the valid
certificates such as conformity certificate or inspection certificate of the equipment, obtain from the service
personnel the Application Form for Replacement of Card as indicated in Annex 2. The local service personnel will,
after examining the equipment information, initiate the relevant procedure for replacement of card. The relevant
department of the Company will deal with the application in accordance with the requirements of such procedure
in time. The new card will be delivered within 2 working days. The new card may be used only after it is
re-authorized. The losses arising from customer’s failure to report the loss of card in time shall be borne by the
customer; if the old card is found after the new card is issued, the old card will be invalidated automatically, and
the new card and production cost may not be returned.
(7) The production cost of every card is RMB300. The local service management officer will collect such costs
and then submit the list of cards to be replaced and costs to the Spare Part Management Center of Marketing
Company.
Management Measures
Management Measures
conditions of hoist, and ask for repair or submit comments and advices. The 400 call center shall be responsible
for sorting out such information, and distribute such information to relevant departments for processing and reply.
(6) If the APP account number or the password is forgotten, please contact the 400 call center so as to obtain the
original account number and password.
Management Measures
Operation and Safety
Electrical Control System
Management Measures
Transportation
Annexes
⑤
Transportation
1. Notices ................................................................................................................................................................. 2
2. Transportation Unit .............................................................................................................................................. 3
Transportation
Transportation
1. Notices
In order to facilitate the packing and get adapted to different transportation modes, the components of the
construction hoist have been disassembled into many separate units.
(1) During the transportation, all components shall be properly fixed;
(2) The light units shall be placed on heavy ones;
(3) In order to protect the painted surface, place cushion or wooden separator between units;
(4) In the course of transportation, prevent sand and soil from entering into structural holes and transmission
components;
(5) Inspect whether any binding tape is loosened;
(6) Inspect the binding conditions for transportation;
(7) When running on any public road, please comply with the corresponding laws and regulations;
(8) When passing any underground passage, bridge or tunnel, be sure to keep sufficient clearance.
Transportation
2. Transportation Unit
Seria H Weigh Remar
Name Dimension L (mm) B (mm)
l No. (mm) t (kg) ks
With
Cage 3400 2600 3000 1495
cab
Ordinary-type
1 BWM-3S
(three-drive Without
3400 1800 3000 1395
super version) cab
Short
1535 300 880 57
pulley
4 Cable trolley
High
1535 300 880 60
pulley
External base
5 enclosure 3100 350 2250 97 Transportation
frame
External base
6 2650 80 1850 57
enclosure
conn
ectin
g
ⅡD 2550 200 1900 135
rod)
Applica
Cable support
12 350 275 425 9 ble to
II
trolley
Applica
Cable support ble to
13 725 120 220 8
III cable
drum
Main base
14 2550 100 3550 172
frame
Auxiliary base
15 1900 100 1250 55
frame
Long base
16 3200 50 1300 26
enclosure
Short base
17 1150 50 1300 10
enclosure
Transportation
End base
18 1550 40 1150 11
enclosure
Drive
assembly
Energy-saving
type BWM-3S 1400 1120 650 504
(two-drive
intelligent
version)
With
cage 3400 2480 3000 1475
cab
Energy-saving
type BWM-3S
(two-drive Without
intelligent 3400 1780 3000 1375
cab
version)
Transportation
⑥
Annexes
1. List of Electrical Elements of Ordinary-type BWM-3S Construction Hoist ......................................................... 2
2. List of Electrical Elements of Energy-saving Type BWM-3S Construction Hoist ............................................... 4
3.List of Wearing Parts of Ordinary-type BWM-3S Construction Hoist .................................................................. 6
4. List of Externally-purchased Parts of Ordinary-type BWM-3S Construction Hoist ........................................... 8
5. List of Wearing Parts of Energy-saving Type BWM-3S Construction Hoist ...................................................... 9
6. List of Externally-purchased Parts of Energy-saving Type BWM-3S Construction Hoist ..................................11
7. Application Form for SIM Card ........................................................................................................................ 12
8. Application Form for IC Card ............................................................................................................................. 13
9. Trouble Explanation and Common Troubleshooting Methods............................................................................ 14
Annexes
Serial
Name Code Model/Specification Quantity Remarks
No.
1 Cabinet 00045012707AB6Z00 1
2 Contactor 1020301031 2
3 Contactor 1020301068 1
4 Accessorial Contact 1020302056 1
Over/Under voltage
5 1020302056 1
relay
6 Relay 1020303114 14
7 Relay Terminal Socket 1020304036 14
8 Thermal Relay 1020304360 2
9 Bell 1020403051 1
10 Breaker 1020602078 3
11 Breaker 1020602549 2
12 Breaker 1020602572 1
13 Breaker 1020604675 1
14 Breaker 1020604806 1
15 7-pin Socket 1020702702 1
16 5-pin Socket 1020702703 1
Switching Power
17 1020903206 1
Supply
Switching Power
18 1020903254 1
Supply
Switching Power
19 1020903255 1
Supply
20 Rectifier Unit 1021904128 1
21 Transformer 1021904178 1
22 Suppresser 1021402370 3
23 Axial Fan 1021000075 2
24 Filter 1029902533 2
Annexes
Note: The right control cabinet is as same as the left control cabinet
Serial
Name Code Model/Specification Quantity Remarks
No.
1 Cabinet 00045012705AD6000 1
2 Contactor 1020301068 1
3 Breaker 1020602078 1
4 Breaker 1020604842 1
5 Transformer 1021904136 1
6 Suppresser 1021402370 1
Annexes
Serial
Name Code Model/Specification Quantity Remarks
No.
1 Cabinet 00045012707AB6Z00 1
2 Contactor 1020301031 2
3 Contactor 1020301068 1
4 Accessorial Contact 1020302056 1
Over/Under voltage
5 1020302056 1
relay
6 Relay 1020303114 14
7 Relay Terminal Socket 1020304036 14
8 Thermal Relay 1020304360 2
9 Bell 1020403051 1
10 Breaker 1020602078 3
11 Breaker 1020602549 2
12 Breaker 1020602572 1
13 Breaker 1020604675 1
14 Breaker 1020604806 1
15 7-pin Socket 1020702702 1
16 5-pin Socket 1020702703 1
Switching Power
17 1020903206 1
Supply
Switching Power
18 1020903254 1
Supply
Switching Power
19 1020903255 1
Supply
20 Rectifier Unit 1021904128 1
21 Transformer 1021904178 1
22 Suppresser 1021402370 3
23 Axial Fan 1021000075 2
24 Filter 1029902533 2
Annexes
Serial
Name Code Model/Specification Quantity Remarks
No.
1 Cabinet 00045012705AD6000 1
2 Contactor 1020301068 1
3 Breaker 1020602078 1
4 Breaker 1020604842 1
5 Transformer 1021904136 1
6 Suppresser 1021402370 1
Annexes
Serial
Name Part Code Model/Specification Quantity Remarks
No.
1 Pinion 000400103B0000001 m=8; z=15 4
Back roller
2 000450102A0004000 4
assembly
3 Roller assembly 000400102B0003000 24
Long roller
4 000400107B0120000 8
assembly
New roller
5 000400102B0008000 8
assembly
For cable
6 Roller assembly 000400113C0203000 4
trolleyⅢ
For cable
7 Roller assembly 000400113C0201000 6/8
trolleyⅢ/Ⅳ
For cable
8 pulley 000400113B0000001 2
trolley
9 Electric motor 1020004045 11kW 6
Disc-type brake
10 5ZJ.275.038 Copper-based asbestos 6
plate
Octangular
11 103040001031 ML8 6 For coupling
cushion rubber
12 Reducer 1030200671 1:16 6
Overspeed safety
13 1999901428 SAJ40-1.2A 2
device
For Cable
Determined
14 Rubber strip 000400110B0100003 guiding
by height
device
Switching power
15 1020901070 NES-15-24 2
supply
16 contactor 1020301031 LC1-D09M7C 4
17 contactor 1020301068 LC1-D95M7C 4 For electric
Thermal cabinet
18 1020304360 NR4-63 20-32A 6
Annexes
relay-contactor
19 Time relay 1020304375 JSZ3F-B 2
20 Delay contact 1020304362 LADR0 0.1-3S 2
21 Transformer 1021904137 2
For operation
22 Master controller 1020103561 2
box
23 Air switch 1020601030 ABE203B 125A 2 For power
24 Transformer 1021904136 2 supply box
Annexes
Quantity
Serial
Name Single Double Model Specification Remarks
No.
Cage Cage
1 Motor 3 6 YZEJ 132M-4 P=11kW JC=25%
TCW125-16 i=16 L=125mm
2 Reducer 3 6 SJ125 i=16
SWC1125 i=16
Rated braking load:
Overspeed safety 40kN
3 1 2 SAJ40-1.2
device Rated braking speed:
1.2m/s
3×16+2×6
3×25+2×10
4 Power cable YCcable
3×35+2×10
3×50+2×16
Bottom diameter
5 Guide roller 20 40
Φ74mm
6 Pinion 3 6 m=8; z=15
7 Rack/each section 1 2 m=8; z=60
Overload
8 1 2 SC-1
protector
9 Inverter 1 2 CS200-4T37GB/ZLP P=37kW
Annexes
Serial
Name Part Code Model/Specification Quantity Remarks
No.
1 Pinion 000400103B0000001 m=8; z=15 4
Back roller
2 000450102A0004000 4
assembly
Double roller
3 000450107A0011000 8
assembly
Side roller
4 000450107A0015000 8
assembly
5 Roller assembly 000450102A0003000 12
For cable
6 Roller assembly 000400113C0203000 4
trolleyⅢ
For cable
7 Roller assembly 000400113C0201000 8/6
trolleyⅢ/Ⅳ
For cable
8 pulley 000400113B0000001 2
trolley
9 Electric motor 1020004045 13kW 4
Disc-type brake
10 5ZJ.275.038 Copper-based asbestos 4
plate
Octangular
11 103040001031 ML8 4 For coupling
cushion rubber
12 Reducer 1030200671 1:16 4
Overspeed safety
13 1999901428 SAJ40-1.2A 2
device
For Cable
Determined
14 Rubber strip 000400110B0100003 guiding
by height
device
Switching power
15 1020901070 NES-15-24 2
supply
16 contactor 1020301031 LC1-D09M7C 4
17 contactor 1020301068 LC1-D95M7C 4 For electric
Thermal cabinet
18 1020304360 NR4-63 20-32A 4
Annexes
relay-contactor
19 Time relay 1020304375 JSZ3F-B 2
20 Delay contact 1020304362 LADR0 0.1-3S 2
21 Transformer 1021904137 2
For operation
22 Master controller 1020103561 2
box
23 Air switch 1020601030 ABE203B 125A 2 For power
24 Transformer 1021904136 2 supply box
Quantity
Serial
Name Single Double Model Specification Remarks
No.
Cage Cage
1 Motor 2 4 YZEJ 132M-4 P=11kW JC=25%
TCW125-16 i=16 L=125mm
2 Reducer 2 4 SJ100 i=16
SWC1125 i=16
Rated braking load:
Overspeed safety 40kN
3 1 2 SAJ40-1.2
device Rated braking speed:
1.2m/s
3×16+2×6
3×25+2×10
4 Power cable YC cable
3×35+2×10
3×50+2×16
Bottom diameter
5 Guide roller 20 40
Φ74mm
6 Pinion 3 6 m=8; z=15
7 Rack/section 1 2 m=8; z=60
Overload
8 1 2 Sensor 50
protector
9 Inverter 1 2 CS200-4T37GB/ZLP P=30kW
Annexes
Reason for Application □ Lost □ Naturally damaged □ Damaged by human factor □ Others
Comments of
Service
Personnel Signature: Date: Seal:
Date of Signature by
Application Applicant
Annexes
Reason for Application □ Lost □ Naturally damaged □ Damaged by human factor □ Others
Comments of
Service
Personnel Signature: Date: Seal:
Date of Signature by
Application Applicant
Annexes
converter is damaged;
3. The HLC is damaged;
9 (Reserved) ……
Annexes
The PIN of SIM card 1. The password for the SIM 1. The PIN of SIM card is wrong;
12 E12
is incorrect card with PIN is wrong 2. Ask for technical support
There is no GPRS 1. The GPRS signal is in bad 1. Change the installation
13 E13
signal conditions position of GPRS antenna
1. The GPRS signal is in bad
1. Change the installation
conditions;
14 The dialing fails E14 position of GPRS antenna
2. The payment for SIM card is
2. Ask for technical support
overdue
1. The server signal is in poor
The connection of Dial 400-887-7748 and contact
15 E15 conditions. Please contact the
server fails the 400 call center
400 call center
16 (Reserved) ……
1. The external base enclosure
is opened; 1. Inspect the external base
2. The emergency stop button enclosure and emergency stop
on power box is pressed down; button on power box;
HLC Trouble
Trouble in phase
17 E21 3. The phase sequence relay is 2. Inspect the phase sequence
sequence relay and its wiring;
connected incorrectly;
4. The HLC is damaged; 3. Inspect the HLC;
5. The phase sequence relay is 4. Ask for technical support
damaged
Annexes
Annexes
is selected)
The cage roof and
drop selection
command is abnormal 1. Inspect the HLC;
34 E40 1. The HLC is damaged;
(The cage roof and 2. Ask for technical support
drop are selected
simultaneously)
The drop state is
abnormal (There are 1. Inspect the HLC;
35 in-cage and cage roof E41 1. The HLC is damaged;
operation signals in 2. Ask for technical support
drop mode)
1. The wiring of INVF point on
Trouble in frequency HLC is loosened;
1. Inspect the connecting
converter (The 2. The relay KA9 is damaged;
terminals of HLC, KA9 and
36 trouble input point of E42 3. The connecting terminals PA frequency converter;
frequency converter is and PB of frequency converter
disconnected) 2. Ask for technical support
are damaged;
4. The HLC is damaged
1. The overload protector is
The overload short-connected; 1. Inspect the overload protector;
37 protector is E43
short-connected 2. The overload protector is 3. Ask for technical support
damaged
Annexes