KEOR HPE 200-250-300
1. TECHNICAL FEATURES ....................................... 1
1. GENERAL FEATURES ............................................... 1
2. INPUT: RECTIFIER AND BATTERY CHARGER ................... 1
3. BATTERIES ............................................................ 1
4. OUTPUT INVERTER ................................................. 2
5. BYPASS ................................................................ 2
6. Block Diagram………………………………………………..2
1. TECHNICAL FEATURES
1. General Features 2. Input: rectifier and battery charger
Power (KVA) 200 250 300 Power (KVA) 200 250 300
UPS Topology ON LINE – Double Conversion Input Three-phase
Nominal Apparent Output Power Nominal input voltage (Vac)
200 250 300 400
(kVA Cosφ 1.0)
Nominal Active Output Power Input voltage range (%) -20/+15
(kW Cosφ 1.0) 200 250 300 Input frequency (Hz) 50 - 60
Efficiency (AC ÷ AC) (%) Input frequency range (%) ±10
@25% load Up to 94,5
Input power factor >0,99
@50% load Up to 95,8
@75% load Up to 96 Input current THD at nominal voltage
@100% load Up to 95,5 and THDV <0,5% (%)
Efficiency (AC ÷ AC) (Eco Mode) >98% @25% load
<9
Heat dissipation at rated load, VFI @50% load
9,4 11,8 14,1 <5
voltage (kW ) @75% load
<3
@100% load
UPS Ambient Temperature (°C) 0 ÷ 40 <3
DC output voltage accuracy (%) ±1
BATTERY ambient temperature (°C) 0 ÷ +25
DC output voltage ripple (%) <1 (RMS)
UPS storage temperature (°C) -10 ÷ +70 Intermittent charging with prevailing state
BATTERY storage temperature (°C) Battery recharging characteristic of complete rest and control of the battery
-15 ÷ +40
status IU (DIN 41773)
Relative humidity % Maximum recharging current (A)
(not condensing) < 95% - at nominal load 30 40 40
Altitude m <1000 (Above Sea level) - with DCM function (max current) 100 100 100
Power derating for altitude > 1000 m AC-DC converter type IGBT-based PFC
According to “IEC62040-3”, 0,5% every 100m
Input protection Fuses
Ventilation Forced
Requested cooling air volume (m3/h) 1800 2200 2300 Nominal current absorbed from mains
302 378 453
(at nominal load and battery charged) (A)
Audible noise level
(according to IEC EN 62040-3) < 65dB Maximum current absorbed from mains
(at nom. load, nom. voltage and max. 423 518 611
Number of cells for standard Lead recharging current) (A)
acid battery 360 ÷ 372
Rectifier soft-start (walk-in) (sec) Settable from 5’’ to 30’’
Protection Degree IP20
Rectifier sequential start-up (hold-off)
Electromagnetic Compatibility EMI According to “IEC EN 62040-2” (CE marking) Settable from 1’’ to 300’’
(sec)
Safety IEC EN 62040-1
Test and performance IEC EN 62040-3
Colour RAL9005 3. Batteries
Power (KVA) 200 250 300
Accessibility Front Access
Sealed lead acid
Installation Against the Wall Type (standard) other on request (VRLA - maintenance free)
Number of Cells 360 - 372
Dimensions (mm) (WxDxH) 880 x 966 x 1976
Floating Voltage at 25°C 812 for 360 cells, 840 for 372 cells
Weight kg (without battery) 720 850 900
Input/output cable connection Cables entry front bottom Minimum Discharge Voltage Vdc 620 for 360 cells, 632 for 372 cells
Transport Base provided for forklift handling Power drawn by the inverter
204,1 255,1 306,1
Storage and transport conditions According to “IEC EN 62040-3” (at rated load cosϕ = 1) (KW)
EN 62040-1 - EN62040-2 - EN62040-3 Power drawn by the inverter
Reference standards (at rated load and minimum battery
ISO 9001:2008 - ISO 14001 329,0 411,0 494
voltage) (KW)
Front panel 10” Touch-screen
Battery Protection Fuses
Voltage-free contact interface Optional for signalisations / alarms
Standard: RS232 - USB Battery Test Provided as Standard
Serial communication interface Optional: RS485 (Mod-Bus RTU protocol)
Up to 5+1 (redundant parallel)
Parallel configuration (optional) Up to 6 (power parallel)
Technical data sheet : UPS-LGR-XXX Updated : 26/06/2018 Page 1/2
87045 LIMOGES Cedex
Numéro de téléphone (+33) 05 55 06 87 87 - Fax : (+33) 05 55 06 88 88
KEOR HPE 200-250-300
4. Output Inverter
Power (KVA) 200 250 300
Inverter Bridge 3-Level IGBT (High Frequency PWM)
6. Block Diagram
Nominal Apparent Output Power
200 250 300
(kVA Cosφ 1.0)
Nominal Active Output Power
200 250 300
(kW Cosφ 1.0)
Efficiency (DC ÷ AC) (%)
@25% load Up to 96
@50% load Up to 97
@75% load Up to 97
@100% load Up to 98
Output 3 Phase / 4 Wires
Rated Output Voltage (selectable)
380-400-415
(Vac)
Output Voltage Stability
- Static (Balanced Load) (%) ±1
- Static (Unbalanced Load) (%) ±2
- Dynamic (Step Load 20%÷ 100% ±5 1. Separate mains input for rectifier and bypass
÷20%) (%)
- Output Volt. Recovery Time(after
2. Rectifier battery-charger
step load) (ms) < 20 3. Battery static switch
- IEC EN 62040-3 VFI-SS-111 4. External battery
Phase Angle Accuracy (°) 5. Inverter
- Balanced Load ±1
- 100% Unbalanced Load ±1
6. Emergency line (bypass)
Output Frequency (selectable) (Hz)
7. Maintenance bypass line
50 / 60 8. Inverter (SSI) and bypass(SSB) static switch
Output Frequency Stability
- Free Running Quartz Oscillator (Hz) ± 0,001 9. Optional contact for external back-feed protection
- Inverter Sync. with Mains (Hz) ± 2 (other on request)
- Slew rate (Hz/s) <1 OPTIONS
Nominal Output Current (@ 400 Vac
output) (A) 289 361 433
5 min >110%…125% 1. BATTERY TEMPERATURE VOLTAGE COMPENSATION
Overload Capability 30 s >125%…150% 2. SERIAL INTERFACE RS-485 (ModBus protocol RTU)
100 ms >150%
3. SNMP ADPTER
Short Circuit Current (A) 720 900 1050 4. PARALLEL CARD INTERFACE KIT
Current limited with electronic protection 5. LOAD-SYNC CARD INTERFACE KIT
Short Circuit Characteristic Automatic stop after 5 seconds 6. ISOLATION TRANSFORMER
Output Waveform Sinewave 7. WALL MOUNTED FUSED SWITCH BOX
Output Harmonic Distortion (%)
- Linear Load <1
- Non Linear Load <5
Fully compliant
SOFTWARE ENABLED FUNCTIONS
- IEC EN 62040-3
Max Crest Factor Up to 3 : 1 1. DIESEL MODE OPERATION
2. RECTIFIER WALK-IN TIME
3. RECTIFIER DELAY ON STARTUP (HOLD-OFF TIME)
4. DYNAMIC CHARGING MODE (DCM)
5. Bypass
5. VFD (ECO) OPERATING MODE MANAGEMENT
6. UHE (ULTRA HIGH EFFICIENCY) OPERATING MODE
Automatic static by-pass Electronic Thyristor Switch
MANAGEMENT
Three-phase + Neutral 7. FREQUENCY CONVERTER
Nominal input voltage (Vac) 380 – 400 - 415
Input voltage range (%) ±10
Input frequency (Hz) 50 - 60
Input frequency range (%) ±10
Transfer mode Without break
In case of:
- Short-circuit
Transfer: inverter - automatic bypass - Battery discharged
- Inverter test
- Inverter failure
- Automatic
Transfer: automatic bypass - inverter - Block on bypass after 6 transfers
within 2 minutes, reset by front panel
Overload Capability (%) 150 Continuously 1000 For 1 Cycle
- Electronically controlled
Manual By-Pass
- No-break assisted re-start procedure
NC contact for the control
Back-feed protection
of an external device