Gsa 240819
Gsa 240819
In this catalogue you will find our total techniques and products of energy
saving compressed air and gas solutions to help customers focus on their
production at ease.
INDEX
Air-cooled/
General HYD-N 4p
water-cooled
Refrigerated
Air Dryers HYD-EP+ Built-in filter
High-Temp 5p
HYD-HT(W) Without filter
Air-cooled/
Air/Gas Chillers General HYD-CH 6p
water-cooled
Standard
Heatless PHL 7p
dew point -40℃
External heater/
Zero purge loss ZEHB 10p
Blower
CO2 Removal
PSA - Below 5ppm 19p
Equipment
CH4 Purfier
Gas
Facility H2 Purifier
He Low Temp.
Purifier
Ar-recovery - - Custom-made 20 p
purifying Equipment
Ar Purifier
SUS HIGH
Heat Exchanger
HGBV
PRODUCT IMAGE
Demister
Expansion
Valve
Technical Specification
Connection Air compressor Flow rate Power consumption Power supply Dimension (mm) Weight
Model
A HP ㎥/min kW V / Ph / Hz A B C kg
5N PT 15A 5 0.7 0.3 355 420 575 30
7N PT 15A 7 1 0.31 355 420 575 30
10N PT 20A 10 1.4 0.32 355 420 575 30
15N PT 25A 15 1.9 0.39 427 507 709 45
220 / 1 / 60
20N PT 25A 20 2.7 0.51 427 507 709 45
30N PT 25A 30 3.9 0.9 358 658 864 66
50N PT 40A 50 6.7 1.4 408 708 952 89
75N PT 50A 75 10.5 2.1 458 798 1045 120
References
■ The numbers in parentheses ( ) are specifications for water-cooled products.
■ Air-cooled products over 800 N are basically external condenser type.
■ R-134a, R-22 refrigerants are used as a standard. R-407c and others are optional.
■ The flow rate is based on 60 Hz and can be custom-made if the electrical specifications are different.
■ Custom-made over 15barg.
■ Models larger than this table are also available and the specification can be changed without notice to improve quality.
Fluid : Compressed Air Dew Point : 2~10℃ @ PDP Pre-filter Line-filter After-filter
Heat Exchanger
PRODUCT IMAGE
HGBV
Demister
Technical Specification
Minimum
Connection Flow rate Built-in filter Power supply Dimension (mm) Weight
Model Power
A ㎥/min μm/ppm/ppm Size kW V / Ph / Hz A B C kg
5EP+ PT 15A 0.7 40/1/0.1 15A 0.3 420 660 760 41
7EP+ PT 15A 1 40/1/0.1 15A 0.31 420 660 760 41
10EP+ PT 20A 1.4 40/1/0.1 20A 0.32 420 660 760 41
15EP+ PT 25A 1.9 40/1/0.1 25A 0.39 425 825 1005 50
220 / 1 / 60
20EP+ PT 25A 2.7 40/1/0.1 25A 0.51 425 825 1005 50
30EP+ PT 25A 3.9 5/1 25A 0.9 450 870 1010 76
Accessories
50EP+ PT 40A 6.7 5/1 40A 1.4 530 1030 1135 99
75EP+ PT 50A 10.5 5/1 40A 2.1 530 1200 1220 135
100EP+ PT 50A 14.2 5/1 50A 2.3 380 / 3 / 60 580 1300 1365 141
H Medium to large capacity high inlet temperature dryer
Y
D 150HT(W) PT 65A 21 4.18 (3.78) 550 1200 1447 220
200HT(W) FLG. 80A 30 4.6 (4.2) 700 1200 1580 260
250HT(W) FLG. 100A 39 5.5 (5.1) 800 1500 1580 340
300HT(W) FLG. 100A 47 5.9 (5.5) 800 1500 1580 360
400HT(W) FLG. 100A 56 9.7 (8.9) 380, 440 / 1000 1900 2015 680
N/A
500HT(W) FLG. 150A 66 12.7 (11.9) 3 / 60 1200 1800 1825 980
Gas Equipments
600HT(W) FLG. 150A 85 14.2 (13.4) 1200 2100 1825 1200
800HT(W) FLG. 200A 120 25.45 (23.2) 1500 1900 2150 1250
900HT(W) FLG. 200A 140 30.15 (27.9) 1500 1900 2150 1320
1200HT(W) FLG. 200A 180 40 (37) 2000 1900 2150 1450
References
■ R-134a, R-22 refrigerants are used as a standard. R-407c and others are optional.
■ Alternative refrigerant specifications can be made.
■ The flow rate is the capacity at 60 Hz.
■ If the electrical specifications are different, it can be custom-made.
■ Products with a pressure of 9.8 barg or higher can be custommade.
Useful Information
Inlet Pressure(barg) +
EP Inlet Temp(℃) HT Inlet Temp(℃) Ambient Temperature(℃) High Efficiency Aluminum Heat Exchanger
A simple and smart controller
Press Factor Temp Factor Temp Factor Temp Factor Reliable drain trap with no compressed air loss
4 0.77 35 1.05 35 1.12 27 1.02 Convenience for users
5 0.86 40 1.00 40 1.05 32 1.00 MEPOL Pipe(Pipe made with advanced manufacturing
6 0.93 45 0.7 45 1.00 37 0.8
methods)
7 1.00 50 0.58 50 0.6 40 0.75
8 1.05 55 0.48 55 0.5 45 0.65
Low differential pressure minimizing compressed air loss
9 1.1 60 0.4 60 0.42 50 0.5 Maximize efficiency by using high-efficiency condenser
Monitoring of air dryer by mobile phone(some products)
SUS HIGH
Heat Exchanger
PRODUCT IMAGE
Auto
Drain
Condenser
Ref.
Compressor
Expansion
Valve
Technical Specification
Power
Connection Flow rate Power supply Dimension (mm) Weight
Model Used Fluid consumption
A ㎥/min kW V / Ph / Hz A B C kg
200CH FLG. 80A 30.0 4.18 380 / 3 / 60 550 1200 1450 225
250CH FLG. 100A 39.0 4.4 440 / 3 / 60 700 1200 1580 240
References
■ R-134a, R-22 refrigerants are used as a standard. R-407c and others are optional.
■ Alternative refrigerant specifications can be made.
■ The flow rate is the capacity at 60 Hz.
■ If the electrical specifications are different, it can be custom-made.
■ It can be custom-made with a pressure of more than 15 barg.
■ Custom-made over 15barg.
■ Specifications are subject to change without notice to improve quality.
Compressed Air
Technical Specification
Power Amount of
Connection Flow rate Power supply Dimension (mm) Weight
Model consumption adsorbent
A ㎥/hr W V / Ph / Hz A B C Kg/2Tower kg
5 PT 15A 10 500 225 745 3 23
S 10 PT 15A 20 500 225 745 4 27
H
L 15 PT 15A 25 500 225 745 7 36
20 PT 15A 35 500 225 745 10 46
25 PT 20A 45 840 305 1010 15 102
Accessories
50 PT 20A 85 840 305 1535 25 136
75 PT 20A 130 1150 435 1665 40 160
100 PT 25A 170 1150 435 1870 50 250
125 PT 25A 215 1150 435 1870 60 260
150 PT 25A 255 1150 435 1870 65 272
200 PT 40A 340 1150 485 1865 90 306
50 220 / 1 / 60
250 PT 40A 425 1270 550 1800 125 405
P 350 PT 40A 595 1270 585 1870 175 473
H
L 500 PT 50A 870 1400 670 2090 250 650
650 PT 50A 1110 1400 670 2350 325 720
800 FLG. 65A 1360 1500 1100 2600 400 900
1000 FLG. 80A 1700 1500 1100 2610 500 1125
1200 FLG. 80A 2040 1800 940 2390 595 1305
1400 FLG. 80A 2380 1800 940 2750 700 1575
Gas Equipments
1600 FLG. 100A 2720 2000 1000 2900 800 1755
1800 FLG. 100A 3060 2000 1000 2900 860 2205
2000 FLG. 100A 3400 2000 1110 2900 1000 2340
References
■ Even under – 40℃ dew point units can be custom-made.
■ ASME or standards other than KS can be custom-made.
■ Products with a design pressure of 9.8 barg or higher are custom-made.
■ Customized-engineering products without this table are also available.
Specifications are subject to change without notice to improve product performance and quality.
Useful Information
Regeneration Air
Compressed Air
Wet Air
Technical Specification
Amount
Connection Flow rate Heater Power supply Dimension (mm) Weight
Model of adsorbent
A ㎥/hr kW V / Ph / Hz A B C kg/2Tower kg
100 FLG. 25A 150 3 870 870 1930 90 300
150 FLG. 40A 250 3.4 970 900 1890 110 350
200 FLG. 40A 370 4 970 900 1990 170 700
285 FLG. 40A 495 4.5 1150 1000 2240 210 750
350 FLG. 50A 660 7.5 1150 1000 2540 280 900
430 FLG. 50A 870 9 1150 1000 2570 390 1000
560 FLG. 65A 1050 10 1250 1100 2670 460 1300
720 FLG. 65A 1380 12 1450 1100 2705 520 1500
900 FLG. 80A 1680 15 1450 1100 2710 700 1800
P 1100 FLG. 80A 1950 18 1600 1400 2750 860 2200
E 1350 FLG. 80A 2280 20.4 380 / 3 / 60 1700 1400 2850 1000 2600
H
1550 FLG. 100A 2950 28.5 1900 1400 2950 1050 3000
2100 FLG. 100A 3700 33 2400 1400 2990 1560 4200
2500 FLG. 125A 4550 36 2500 1600 3250 2000 4800
3000 FLG. 150A 5400 44 2500 1600 3250 2100 5200
4100 FLG. 150A 6600 56 3000 2000 3250 2900 6000
4500 FLG. 150A 7500 62 3000 2000 3250 3200 6300
5400 FLG. 150A 8500 70 3200 2000 3300 3780 6800
6000 FLG. 200A 10500 85 3900 2300 3430 4200 7500
7000 FLG. 200A 12000 100 4600 2130 3150 4900 9000
9000 FLG. 250A 15000 110 5000 2500 3150 6400 10000
References
■ Even under – 40℃ dew point units can be custom-made.
■ ASME or standards other than KS can be custom-made.
■ Products with a design pressure of 9.8 barg or higher are custom-made.
■ Customized-engineering products without this table are also available.
■ Specifications are subject to change without notice to improve product performance and quality.
Regeneration Air
Compressed Air
Accessories
430 FLG. 50A 870 9 1.75 1150 1200 2570 390 1200
560 FLG. 65A 1050 10 3 1250 1300 2670 460 1500
720 FLG. 65A 1380 12 3 1450 1400 2700 520 1800
900 FLG. 80A 1680 15 3 1450 1400 2705 700 2000
P 1100 FLG. 80A 1950 18 6.3 1700 1600 2750 860 2400
E
1350 FLG. 80A 2280 20.4 6.3 380 / 3 / 60 1700 1700 2850 1000 2900
H
B 1550 FLG. 100A 2950 28.5 7.5 1900 1700 2950 1050 3400
2100 FLG. 100A 3700 33 9 2400 1800 2990 1560 4000
3000 FLG. 150A 5400 44 13 2500 1950 3250 2100 4800
4100 FLG. 150A 6600 56 15 3200 2300 3250 2900 6000
4500 FLG. 150A 7500 62 15 3200 2400 3250 3200 6500
5400 FLG. 150A 8500 70 20 3200 2500 3300 3780 7300
Gas Equipments
6000 FLG. 200A 10500 85 22 3400 2500 3430 4200 8100
7000 FLG. 200A 12000 100 27 3600 2500 3430 4900 10300
9000 FLG. 250A 15000 110 30 4000 3000 3430 6400 12300
References
■ Even under – 40℃ dew point units can be custom-made.
■ ASME or standards other than KS can be custom-made.
■ Products with a design pressure of 9.8 barg or higherare custom-made.
■ Customized-engineering products without this table are also available.
■ Specifications are subject to change without notice to improve product performance and quality.
Useful Information
Regeneration Air
Compressed Air
Technical Specification
Amount
Connection Flow rate Air compressor Heater Blower Power supply Dimension (mm) Weight
Model of absorbent
A ㎥/hr HP kW kW V / Ph / Hz A B C kg/2Tower kg
430 FLG. 40A 680 75 8.5 1.5 1900 900 2030 324 1440
560 FLG. 50A 890 100 11.0 1.75 2100 1000 2230 406 1700
720 FLG. 50A 1140 130 14.0 2.55 2100 1000 2230 474 2060
900 FLG. 65A 1430 150 17.5 2.55 2600 1250 2400 592 2200
1100 FLG. 65A 1740 175 21.5 4.5 2600 1250 2400 755 2470
1350 FLG. 80A 2140 200 26.5 4.5 2600 1670 2330 943 2690
1550 FLG. 80A 2450 250 30.0 4.5 2600 1710 2330 1,022 3100
220V/380V
2100 FLG. 100A 3320 300 41.0 8.6 3100 1650 2445 1,384 4090
Z 440V
E 2600 FLG. 100A 4120 400 50.5 8.6 3400 1970 2290 1,848 4700
H 3000 FLG. 125A 4750 500 58.5 12.6 1Ph 3550 1970 2290 1,980 5860
B
3400 FLG. 125A 5380 600 66.0 12.6 3650 2140 2530 2,272 7400
50/60Hz
4100 FLG. 125A 6490 700 80.0 15.3 3650 2180 2530 2,707 8200
4500 FLG. 150A 7120 800 87.5 22.7 5700 2100 2960 3,055 9600
5400 FLG. 150A 8550 900 105.0 22.7 5700 2100 2960 3,566 11400
6000 FLG. 150A 9500 1000 117.0 22.7 6000 2150 3000 4,052 12300
7000 FLG. 200A 11080 1200 136.0 25.2 7000 2200 3500 4,621 13500
8000 FLG. 200A 12660 1300 155.5 30.6 7000 2500 3700 5,279 14700
9000 FLG. 200A 14520 1600 175.0 37.0 7000 2500 3700 5,942 15600
References
■ Even under – 40℃ dew point units can be custom-made.
■ ASME or standards other than KS can be custom-made.
■ Products with a design pressure of 9.8 barg or higher are custom-made.
■ Customized-engineering products without this table are also available.
■ Specifications are subject to change without notice to improve product performance and quality.
Moist compressed air passes through the hollow fiber module, allowing fast diffusion
and rapid passage of moisture to escape from the hollow fiber, removing moisture from
the compressed air and discharging it through the silencer with purge air
Moisture - Hydrogen - Helium - Carbon dioxide - Oxygen - Argon - Carbon
PRODUCT IMAGE
Accessories
How to control the amount of PDM purge
· Refer to the adjustment figure and adjust the six corners of the adjustment valve by rotating them 60 degrees relative to the outlet
cap bolt. Refer to the table below for purge flow rates per 60-degree rotation.
Angle of rotation(˚)
1 rotation = 6 clocks
(60 degrees rotation) Purge flow rate(LPM)
Gas Equipments
A Wet
수분과 compressed
이물질이 제거되지air without
않은 습한removing
압축공기 moisture and foreign substances. If the conditions of use are different, the change in the treatment flow
PMD Recommendation System
B Clean
수분과 compressed
이물질이 제거된 air 깨끗한
with moisture
압축공기 and foreign substances removed.
Inlet Pressure(barg)
Installation location restrictions are small Ultra-precise measurement and analysis equipment
Energy consumption is low due to low electricity usage Medical(Dental use)
There is no additional maintenance other than replacing Prevention of Freezing
the shear filter Drying of powder
The highest quality Hosing case was used CDA(Clean Dried Air)
Technical Specification
Summer Season 4 ~ 10 ℃
6 Outlet Dew Point
Winter Season -40 ℃
■ The regenerative heater of the adsorption dryer consumes less electricity, and in the case of the zero purge type, there is no regenerative air
consumption, reducing operating costs.
■ The adsorbent replacement cycle is long and the amount of adsorbent is small, reducing costs when replacing the adsorbent.
■ Stable dew point guaranteed by combination with specially designed refrigerated dryer.
GSA's combination air dryer is the best solution for realizing carbon neutrality by saving energy and increasing efficiency.
2. Filtering Layer
PRODUCT IMAGE
3. Main Layer
4. Coalescing Layer
Filter Elements
Differential pressure indicator
Particle Oil Removal Max operating Temp Differential Pressure (barg) Elements
Model (replacement of element)
removal (@ 20’C)
℃ Dry Wet DPI Color Month Colour Material
40 40 Micron - 0.05 0.15 White Polyethylene
65
5 5 Micron - 0.05 0.15 White Polyethylene
H 1 1 Micron 1 ppm 0.15 0.3 Red Borosilicate
6
Y RED
E 0.1 1 Micron 0.1 ppm 0.15 0.3 White Borosilicate
54
0.01 1 Micron 0.01 ppm 0.15 0.3 Yellow Borosilicate
0.003 - 0.003 ppm 0.1 0.2 White Activated Carbon
Accessories
Filter
Flow rate Max Pressure Connection Quantity of element Dimension Weight
Model
㎥/min CFM barg A EA (A x B) mm kg
15AN 0.8 28 PT 15A 1 85 x 185 0.8
20AN 1.7 60 PT 20A 1 85 x 225 1
25AN 3.4 120 13 PT 25A 1 105 x 330 1.9
40AN 10 353 PT 40A 1 165 x 440 5.5
50AN 14 494 PT 50A 1 165 x 540 6.5
H 65A 28 989 FLG. 65A 2 550 x 1143 88
Y
F 80A 42 1483 FLG. 80A 3 550 x 1143 103
Gas Equipments
100A 70 2472 FLG. 100A 5 600 x 1180 120
125A 84 2966 9.7 FLG. 125A 6 700 x 1251 170
150A 112 3955 FLG. 150A 8 700 x 1251 180
200A 196 6922 FLG. 200A 11 1000 x 2367 300
250A 330 11654 FLG. 250A 19 1200 x 2705 400
High-pressure filter
Flow rate Max Pressure Connection Quantity of element Dimension Weight
Model
㎥/min CFM barg A EA (A x B) mm kg
15H 1 35 PT 15A 1 106 x 340 17
References
■ Special pressure or stainless steel is custom made.
■ The filter support is a standard for HYF-125A or bigger models.
■ HYE - XX - 50A (bolt type) is applied to the element of HYF-65A or higher, and the quantity varies depending on the model,
so please check the quantity before ordering.
■ Filter nomenclature
- Filter Model : HYF-40-15AN(filter - filtering rate - connection diameter)
- Element Model : HYE-40-15AN(Element - filtering rate - Connection Diameter)
V = { P1 x (Q1 - Q2) x t } / ( P2 - P3 )
Technical Specification
Capacity Connection O.D. Height (H) Anchor Hole Weight
Model
m3 A mm mm mm kg
0003A 0.3 25A 609 1,450 16 150
References
■ ASME specifications other than KS specifications can also be custom-made.
■ High-pressure products with high design pressure can also be custom-made.
■ Customized-engineering products without this table are also available.
■ Specifications are subject to change without notice to improve product performance and quality.
HDI30
Accessories
TECHNICAL DATA
Operating Temp 2 ~ 60 ℃
Operating Press Max. 16 barg
Green Area 0 ~ 0.6 bar
Gas Equipments
Red Area 0.6 ~ 0.9 bar
Mounting Bolt M5
Dimension(D x L x H , mm) 40 x 40 x 35
Weight 0.03 kg
Desiccant
A desiccant used includes carbon molecular sieve (CMS) and zeolite molecular sieve (ZMS) for nitrogen and oxygen production,
including activated alumina needed to dehumidify compressed air.
Technical Specification
Nitrogen Capacity (m³/h)
95% 9.3 16.2 23.6 37.9 55.0 67.4 82.7 100.4 145.8 228.5 301.5 409.3 479.8 648.3
(1.5N)
97% 8.6 14.9 21.7 34.9 50.7 62.1 76.1 92.5 134.2 210.4 277.5 376.8 441.7 596.8
(1.7N)
98% 8.1 14.2 20.7 33.2 48.3 59.1 72.4 88.0 127.6 200.14 264.0 358.4 420.1 567.7
(1.8N)
99% 7.4 12.9 18.8 30.2 43.9 53.7 65.9 80.0 116.1 182.0 240.1 326.0 382.1 516.3
(2N)
99.50% 6.7 11.7 17.1 27.5 40.0 48.9 60.0 72.9 105.8 165.8 218.7 297.0 348.1 470.4
(2.5N)
99.90% 5.4 9.5 13.8 22.1 32.2 39.4 48.4 58.7 85.2 133.6 176.3 239.4 280.6 379.1
(3N)
99.95% 4.6 8.0 11.6 18.6 27.0 33.1 40.6 49.3 71.5 112.2 147.9 200.9 235.5 318.2
(3.5N)
99.99% 3.8 6.7 9.7 15.6 22.7 27.7 34.0 41.3 60.0 94.1 124.1 168.5 197.5 266.8
(4N)
99.999% 2.6 4.6 6.7 10.8 15.7 19.2 23.5 28.6 41.5 65.1 85.9 116.6 136.7 184.7
(5N)
Dimensions (mm)
L 2,200 2,600 2,800 3,000 3,500 3,600 3,700 3,800 4,100 4,900 5,300 6,000 6,200 6,400
W 1,300 1,450 1,750 2,100 2,300 2,450 2,450 2,550 2,700 3,300 3,600 4,100 4,400 4,600
H 2,050 2,050 2,050 2,100 2,100 2,100 2,300 2,350 2,650 2,700 2,800 3,200 3,250 3,300
References
■ Models under membrane type as well as PSA are also customizable.
■ Models under ASME in addition to KS are also customizable.
■ Large models bigger than those stated in the specifications above
are also customizable.
■ The Specifications are subject to changes without notice for product
improvement.
Nomenclature
GNG - XX - XXX
Purity
Product Flow Rate
90% 1.7 2.9 4.3 6.8 9.9 12.1 14.9 18.1 26.2 41.1 54.2 73.7 86.3 116.6
93% 1.5 2.7 3.9 6.3 9.1 11.1 13.6 16.6 24.0 37.7 49.7 67.5 79.1 106.9
95% 1.4 2.5 3.6 5.8 8.4 10.3 12.6 15.3 22.2 34.8 46.0 62.4 73.2 98.9
Dimensions (mm)
Accessories
L 2,100 2,400 2,650 2,850 3,300 3,400 3,550 3,650 4,000 4,700 5,100 5,800 6,000 6,200
W 1,200 1,350 1,600 1,950 2,150 2,350 2,400 2,500 2,600 3,100 3,500 4,000 4,250 4,500
H 2,000 2,050 2,100 2,100 2,100 2,100 2,200 2,230 2,540 2,600 2,700 3,000 3,150 3,300
Capa. 19 33 48 77 112 137 168 204 296 464 612 831 974 1,316
Components
Power consumption (kW)
Ref. Dryer 0.46 0.62 0.68 0.72 1.3 1.3 1.6 1.6 2.1 2.3 3.0 4.6 5.1 8.5
Gas Equipments
Oxy. Gener. 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Total 5.46 7.12 9.18 12.72 17.3 20.3 24.6 29.6 40.1 58.3 79.0 95.6 116.1 159.5
References
■ Models under VSA as well as PSA are also customizable.
■ Models under ASME in addition to KS are also customizable.
■ Large models bigger than those stated in the specification
above are also customizable.
■ The specifications are subject to changes without notice for
product improvement.
Useful Information
Nomenclature H
GOG - XX - XXX
Purity
W
Fluid : Hydrogen
수소 드라이어의 구성
수소 드라이어의 장치 시스템 구성
Utilization and Installation of Hydrogen Dryer
As interest and demand for eco-friendly energy resources are 물 배출구
water outlet H2
H2가스
Gas출구
Exit
gradually increasing due to greenhouse gas problems such 흡착탑-A
Adsorption Top-A 재생 쿨러 Cooler
Recycled 안전 밸브valve
Safety
as carbon dioxide and climate change, hydrogen is attracting
H2
H2가스
Gas입구
entrance 흡착탑-B
Absorption TopB 방폭 배선함 proof wiring box
Explosion 방폭 제어함
attention as a new energy resource to replace fossil fuels.
Hydrogen is the ultimate eco-friendly energy source and
is a clean and infinite resource that does not generate any
byproducts other than water, and its application fields have
recently been expanding, including hydrogen fuel cells and
automobiles.As hydrogen is attracting attention as an alternative
energy source, interest in how to produce hydrogen is also
growing. The most commonly used methods of hydrogen
production include the use of by-product hydrogen separately
generated by petrochemical processes, and the natural gas
reforming method that decomposes natural gas into high-
temperature/high-pressure water vapor to produce hydrogen.
The natural gas reforming method is the most widely used
method and has the advantage of producing hydrogen at a
low cost. Finally, there is a water electrolysis method that
electrolyzes water to get hydrogen.Since the purity of hydrogen
has a significant impact on the performance of fuel cells,
refining techniques for obtaining high purity hydrogen are very
important. A hydrogen dryer is a device that purifies hydrogen
by removing oxygen in hydrogen in the form of moisture using a
Pd (palladium) catalyst and an adsorbent.
Compressed Air
Technical Specification
No. Description Specification Unit
Accessories
4 Feed Air CO2 Purity ≤ 450 ppm
Adsorption 4 hr
Standard
7 Heating Regeneration 2.5 hr
Process Time
Cooling Regeneration 1.5 hr
Operation of the CO2 removal unit is performed automatically according to the sequence of PLCs or mycoms. Compressed air containing moisture and
CO2 flows into the lower part of the two adsorption towers under the adsorption process and then through the adsorbate layer and into the upper part.
In the process of moving up, the difference in diffusion rate due to the pores of the adsorbent separates moisture and CO2 from compressed air and
supplies dry compressed air from which CO2 has been removed. While one of the two adsorption towers is undergoing the adsorption process, the other
is subjected to a regenerative process. The regeneration process consists of a heating process and a cooling process, and the heating process uses
high-temperature air heated by an electric heater to adsorbate moisture and CO2 components adsorbed on the adsorbent and then release them to the
atmosphere. The cooling process is a regenerative process that cools the heated adsorbent to achieve good adsorption. When the heating and cooling
regeneration processes are completed, a dynamic pressure process is performed to raise the regeneration tower to the same pressure as the supply
pressure. After the dynamic pressure process is completed, the two adsorption towers are switched and the adsorption tower that has undergone the
adsorption process is subjected to a regeneration process, and the adsorption tower that has undergone the regeneration process is subjected to an
adsorption process. This series of processes proceed automatically in a given sequence and continues to supply dry air with CO2 removed.
Ar Recovery & Purification System Ar Purifier Carbon dioxide(CO2) purification and liquefaction Equipment
After pre-treating the recovered argon, re- Supply of high purity argon by removing N2, Carbon dioxide produced by increased de-
move nitrogen, oxygen, and moisture using O2, CO2, and CO components in stored argon mand for energy and various causes ac-
an adsorbent to supply it. using Pd catalyst and adsorbent to reduce counts for 80% of greenhouse gases, but is
the impurity concentration of 10 ppm or less used in various fields Carbon dioxide (CO2)
to 10 ppb or less. purification and liquefaction facility for re-
moving impurities from collected carbon di-
■ High-pressure argon refining equipment oxide and liquefaction.
■ Low-pressure argon refining facilities
Accessories
Flexibility The fast delivery
GSA offers maximum flexibility in production as well as GSA optimally manages the production load by applying the
design. For example, if a customer can save on shipping or integrated production management system to the production
shipping costs, we strive from the customer's point of view line to meet the delivery date and shipment deadline that
Gas Equipments
by reducing the height or width of the product so that it can the customer wants. At the same time, for urgent orders
be placed in a regular or HQ container rather than a Flat Rack from customers, customer-oriented production flexibility is
container. used to meet the delivery date.
Thorough
Quality
management
Flexibility Reliability
Customer
Useful Information
satisfaction
Realization
Reasonable Price
GSA provides high-quality products at a reasonable The Fast Reasonable
level as a result of significant cost savings without Delivery Price
compromising quality through mass ordering of materials
and simplificationof manufacturing processes.
At 7.0 bar, pressure dew point -18℃, what is the atmospheric pressure dew point?
Locate the pressure dew point -18℃ on the right side of the chart, draw a horizontal line to the left, and go
down vertically from the point where the pressure intersects the pressure line at 7.0 bar to obtain the pressure
dew point -40℃.
(Pressure 7.0 bar, Pressure Dew Point -18℃ can be converted to atomic Dew Point -40℃ by following the
line 1) What is the pressure dew point at the pressure 7.0 bar at -18℃?
Locate the atmospheric pressure dew point -18℃ at the bottom of the chart and draw a vertical line and follow
it horizontally at the point where it intersects the pressure line at 7.0 bar to obtain the atmospheric pressure
dew point of 10℃.
(Atmospheric Pressure, Dew Point -18℃ can be converted to 7.0bar Pressure Dew Point 10℃ by following the line ②)
압력노점
Pressure DewDew
Pressure Point (℃)
Point(℃)
Pressure 82
압력
Pressure
(bar) 77
(bar)
71
66
60
54
49
43
38
32
27
21
16
2 2 10
4
-1
-7
-12
210
1 1 -18
-23
140
70
-29
32 -35
28 -40
14 -46
7.0 -51
3.0 -57
1.4
-63
0.35
-68
-73
1 2
-70 -63 -57 -51 -46 -40 -35 -29 -23 -18 -12 -7 -1 4
Atmospheric
대기압노점 Pressure Dew Point
Atmospheric Pressure Dew Point
22 | Global Standard Air / Gas
Amount of Saturated Water Vapor Table
RH 100% : g/m3
Accessories
45℃ 65.3500 13℃ 11.3430 -19℃ 0.9673 -52℃ 0.0299
Compressed air is saturated with water. Since the compressed air is heated during the compression, aftercooler
is then used to remove the heat of compression. During this stage, when ambient air is compressed, a significant
quantity of condensate is made.
This condenstate, if not removed, will cause erosion, damage to pneumatic equipment and instruments. Filtering
and drying processes remove particles, moisture, microbes, and chemicals from compressed air. Clean, dry air
protects the air system reduces maintenance costs and incrases finished product yields.
PP
Accessories
Dew Point 4℃ | Total Oil 0.1 ppm | Particle 1 μm
Gas Equipments
Air Craft Marine&Automobile Petroche-mical Automation Chemistry PrecisePainting
Enginestarting Control System Refinery Control System Laboratory Powder Painting
Service Air Enginestarting Production Starting System Control System Coating
Service Airr Service Air Storage
Conveyor System Control System
Gas Generator/Purifier
GSA leads the gas generators and refineries industry. The following items
are designed and manufactured by us: PSA-type nitrogen generators,
oxygen generators, hydrogen purifiers, argon/carbon monoxide/carbon/
methane recovery purification plants, and other various gas separation and
purification plants are custom-made.
Air/Gas chiller
GSA designs and manufactures special purpose air/gas chiller. GSA's air-
Global Standard Air
www.gsadryer.com