0% found this document useful (0 votes)
109 views26 pages

Gsa 240819

GSA – Global Standard Air/Gas is a South Korean company established in 1993, specializing in the development and manufacturing of compressed air and gas treatment equipment. The company offers a wide range of products including air dryers, chillers, gas generators, and filters, focusing on quality, innovation, and customer satisfaction. Their catalog features energy-saving solutions designed to enhance production efficiency for their customers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views26 pages

Gsa 240819

GSA – Global Standard Air/Gas is a South Korean company established in 1993, specializing in the development and manufacturing of compressed air and gas treatment equipment. The company offers a wide range of products including air dryers, chillers, gas generators, and filters, focusing on quality, innovation, and customer satisfaction. Their catalog features energy-saving solutions designed to enhance production efficiency for their customers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 26

GSA – Global Standard Air/Gas is development and manufacturing

organization producing various compressed air/gas dryers, air/gas chiller,


gas generators, gas purifiers, air/gas filters, condensate drains etc.

The company was founded in Korea in 1993 and restarted as GSA in


2003. Over these years, the company has earned a reputation that has a
unique combination of quality, value, trust and reliability.

GSA is a very innovative, customer oriented and technology driven


company. We always strive to provide world top quality products for
compressed air treatment and gas generation supporting you and your
business with our solutions.

In this catalogue you will find our total techniques and products of energy
saving compressed air and gas solutions to help customers focus on their
production at ease.
INDEX

Equipment Type Model Remark Page

Air-cooled/
General HYD-N 4p
water-cooled
Refrigerated
Air Dryers HYD-EP+ Built-in filter
High-Temp 5p
HYD-HT(W) Without filter

Air-cooled/
Air/Gas Chillers General HYD-CH 6p
water-cooled
Standard
Heatless PHL 7p
dew point -40℃

Heated purge PEH External heater 8p


Desiccant
Air Dryers External heater/
Compressed Blower purge PEHB 9p
air facility Blower

External heater/
Zero purge loss ZEHB 10p
Blower

Membrane Dryer Membrane PMD Dew Point -20℃ 11p

Combination Ref. & Desiccant


Combination GCBD 12p
Air Dryers Air Dryer

Air/Gas Filters HYF Filter/Elements 13p

Auxiliary Pressure vessel


Air Receiver Tanks GS 14p
Equipment inspection product
Drain/ differential
Drain & others HAD pressure gauge 15p
and others
Nitrogen
PSA GNG 95~99.999% 16p
Generator
Oxygen
PSA / VSA GOG 90~95% 17p
Generator

H2 dryer PSA - Custom-made 18p

CO2 Removal
PSA - Below 5ppm 19p
Equipment

CH4 Purfier
Gas
Facility H2 Purifier

He Low Temp.
Purifier
Ar-recovery - - Custom-made 20 p
purifying Equipment

Ar Purifier

CO2 Purifying and


liquefaction
Equipment

Global Standard Air / Gas


HYD-N
Refrigerated air dryer(Non-cycling)
OPTION

SUS HIGH

DESIGN DATA FLOW DIAGRAM


MATERIAL PRESSUPE

Fluid : Compressed Air Dew Point : 2~10℃ @ PDP


Wet Air Dry Air

Inlet Pressure 7barg Inlet Temperature 38℃


Design Pressure 14barg Ambient Temperature 32℃

Heat Exchanger

HGBV
PRODUCT IMAGE

Demister

Auto Condenser Ref.


Drain Compressor

Expansion
Valve

Technical Specification
Connection Air compressor Flow rate Power consumption Power supply Dimension (mm) Weight
Model
A HP ㎥/min kW V / Ph / Hz A B C kg
5N PT 15A 5 0.7 0.3 355 420 575 30
7N PT 15A 7 1 0.31 355 420 575 30
10N PT 20A 10 1.4 0.32 355 420 575 30
15N PT 25A 15 1.9 0.39 427 507 709 45
220 / 1 / 60
20N PT 25A 20 2.7 0.51 427 507 709 45
30N PT 25A 30 3.9 0.9 358 658 864 66
50N PT 40A 50 6.7 1.4 408 708 952 89
75N PT 50A 75 10.5 2.1 458 798 1045 120

H 100N PT 50A 100 14.2 2.3 458 858 1145 126


Y 150(W)N PT 65A 150 21(22.5) 2.9(2.5) 565 1005 1330 172(170)
D 200(W)N FLG. 80A 200 30(32.1) 4.18(3.78) 550 1200 1447 240(230)
250(W)N FLG. 100A 250 39(41.7) 4.4(4) 700 1200 1580 260(250)
300(W)N FLG. 100A 300 47(50.3) 4.6(4.2) 380 / 3 / 60 700 1200 1580 270(260)
400(W)N FLG. 100A 400 56(59) 9.7(8.9) 900 1591 1915 600(500)
500(W)N FLG. 150A 500 66(70.6) 11.7(10.9) 440 / 3 / 60 1200 1800 1830 940(780)
600(W)N FLG. 150A 600 85(91) 12.7(11.9) 1200 1800 1830 1100(780)
800(W)N FLG. 200A 800 120 20(18.5) 1500 1900 2150 1200(950)
900(W)N FLG. 200A 900 140 25.45(23.2) 1500 1900 2000 1250(1,010)
1200(W)N FLG. 200A 1200 180 30.15(27.9) 2000 1900 2150 1400(1,300)

References
■ The numbers in parentheses ( ) are specifications for water-cooled products.
■ Air-cooled products over 800 N are basically external condenser type.
■ R-134a, R-22 refrigerants are used as a standard. R-407c and others are optional.
■ The flow rate is based on 60 Hz and can be custom-made if the electrical specifications are different.
■ Custom-made over 15barg.
■ Models larger than this table are also available and the specification can be changed without notice to improve quality.

FACTOR CHARACTERISTICS DIMENSION


Inlet Pressure(barg) Inlet Temperature(℃) Ambient Temperature(℃) High Efficiency Aluminum Heat Exchanger
Simple and smart controller
Press Factor Temp Factor Temp Factor
Efficient separation technology of condensate
4 0.77 11 1.18 25 1.15 27 1.02
Reliable drain trap with no compressed air loss
5 0.86 12 1.21 30 1.05 32 1.00
Low differential pressure minimizing compressed
6 0.93 13 1.24 38 1.00 37 0.8 air loss
7 1.00 14 1.27 43 0.7 40 0.75 Maximize efficiency by using high-efficiency
8 1.05 47 0.6 45 0.65
9 1.1 50 0.55 50 0.5 condenser
10 1.14 Monitoring of air dryer by mobile phone
(some products)

4 | Global Standard Air / Gas


HYD-EP +
OPTION
Eco Pro plus+ energy saving ref, air dryer(Cycling)
SUS HIGH

DESIGN DATA FLOW DIAGRAM


MATERIAL PRESSUPE

Fluid : Compressed Air Dew Point : 2~10℃ @ PDP Pre-filter Line-filter After-filter

Wet Air Dry Air

Ref. Air Dryers


Inlet Pressure 7barg Inlet Temp 40℃ (Max. 60℃)
Design Pressure 9barg Ambient Temperature 32℃

Heat Exchanger
PRODUCT IMAGE

HGBV

Demister

Auto Condenser Ref.


Drain Compressor

Desiccant Air Dryers


Expansion
Valve

Technical Specification
Minimum
Connection Flow rate Built-in filter Power supply Dimension (mm) Weight
Model Power
A ㎥/min μm/ppm/ppm Size kW V / Ph / Hz A B C kg
5EP+ PT 15A 0.7 40/1/0.1 15A 0.3 420 660 760 41
7EP+ PT 15A 1 40/1/0.1 15A 0.31 420 660 760 41
10EP+ PT 20A 1.4 40/1/0.1 20A 0.32 420 660 760 41
15EP+ PT 25A 1.9 40/1/0.1 25A 0.39 425 825 1005 50
220 / 1 / 60
20EP+ PT 25A 2.7 40/1/0.1 25A 0.51 425 825 1005 50
30EP+ PT 25A 3.9 5/1 25A 0.9 450 870 1010 76

Accessories
50EP+ PT 40A 6.7 5/1 40A 1.4 530 1030 1135 99
75EP+ PT 50A 10.5 5/1 40A 2.1 530 1200 1220 135
100EP+ PT 50A 14.2 5/1 50A 2.3 380 / 3 / 60 580 1300 1365 141
H Medium to large capacity high inlet temperature dryer
Y
D 150HT(W) PT 65A 21 4.18 (3.78) 550 1200 1447 220
200HT(W) FLG. 80A 30 4.6 (4.2) 700 1200 1580 260
250HT(W) FLG. 100A 39 5.5 (5.1) 800 1500 1580 340
300HT(W) FLG. 100A 47 5.9 (5.5) 800 1500 1580 360
400HT(W) FLG. 100A 56 9.7 (8.9) 380, 440 / 1000 1900 2015 680
N/A
500HT(W) FLG. 150A 66 12.7 (11.9) 3 / 60 1200 1800 1825 980

Gas Equipments
600HT(W) FLG. 150A 85 14.2 (13.4) 1200 2100 1825 1200
800HT(W) FLG. 200A 120 25.45 (23.2) 1500 1900 2150 1250
900HT(W) FLG. 200A 140 30.15 (27.9) 1500 1900 2150 1320
1200HT(W) FLG. 200A 180 40 (37) 2000 1900 2150 1450

References
■ R-134a, R-22 refrigerants are used as a standard. R-407c and others are optional.
■ Alternative refrigerant specifications can be made.
■ The flow rate is the capacity at 60 Hz.
■ If the electrical specifications are different, it can be custom-made.
■ Products with a pressure of 9.8 barg or higher can be custommade.
Useful Information

■ Larger models beyond the specifications are also available.


■ Specifications may be changed without notice to improve quality
FACTOR CHARACTERISTICS DIMENSION

Inlet Pressure(barg) +
EP Inlet Temp(℃) HT Inlet Temp(℃) Ambient Temperature(℃) High Efficiency Aluminum Heat Exchanger
A simple and smart controller
Press Factor Temp Factor Temp Factor Temp Factor Reliable drain trap with no compressed air loss
4 0.77 35 1.05 35 1.12 27 1.02 Convenience for users
5 0.86 40 1.00 40 1.05 32 1.00 MEPOL Pipe(Pipe made with advanced manufacturing
6 0.93 45 0.7 45 1.00 37 0.8
methods)
7 1.00 50 0.58 50 0.6 40 0.75
8 1.05 55 0.48 55 0.5 45 0.65
Low differential pressure minimizing compressed air loss
9 1.1 60 0.4 60 0.42 50 0.5 Maximize efficiency by using high-efficiency condenser
Monitoring of air dryer by mobile phone(some products)

GSA Ref. Air Dryers | 5


HYD-CH
Air & Gas chiller
OPTION

SUS HIGH

DESIGN DATA FLOW DIAGRAM


MATERIAL PRESSUPE

Fluid : Compressed Air & Gas

Hot Air/Gas Cool Air/Gas


Inlet Pressure 7barg Inlet Temperature 32℃
Design Pressure 14barg Temp. Difference(ΔT) 15℃
Demister

Heat Exchanger
PRODUCT IMAGE

Auto
Drain

Condenser
Ref.
Compressor
Expansion
Valve

Technical Specification
Power
Connection Flow rate Power supply Dimension (mm) Weight
Model Used Fluid consumption
A ㎥/min kW V / Ph / Hz A B C kg

5CH PT 15A 0.5 0.32 245 555 755 32

7CH PT 15A 0.8 0.33 245 555 755 32

10CH PT 15A 1 0.34 245 555 755 32

15CH PT 25A 1.5 0.5 425 505 710 41


220 / 1 / 60
20CH PT 25A 2.6 0.58 425 505 710 41

30CH PT 25A 3.9 0.91 355 655 865 62


Pressed Air
H 50CH / PT 40A 6.7 1.39 405 705 955 83
Y Nitrogen
D 75CH / PT 50A 10.5 2.05 455 795 1045 115
Other Gases
100CH PT 50A 14.2 2.34 455 855 1145 120

150CH PT 65A 21.0 2.89 565 1005 1330 165

200CH FLG. 80A 30.0 4.18 380 / 3 / 60 550 1200 1450 225

250CH FLG. 100A 39.0 4.4 440 / 3 / 60 700 1200 1580 240

300CH FLG. 100A 47.0 4.6 700 1200 1580 245

400CH FLG. 100A 56.0 9.7 900 1590 1915 560

References
■ R-134a, R-22 refrigerants are used as a standard. R-407c and others are optional.
■ Alternative refrigerant specifications can be made.
■ The flow rate is the capacity at 60 Hz.
■ If the electrical specifications are different, it can be custom-made.
■ It can be custom-made with a pressure of more than 15 barg.
■ Custom-made over 15barg.
■ Specifications are subject to change without notice to improve quality.

FACTOR CHARACTERISTICS DIMENSION


High Efficiency Aluminum Heat Exchanger
Inlet Pressure(barg) Inlet Temperature(℃) Ambient Temperature(℃) A smart controller incorporating a variety of the

Press Factor Temp Factor Temp Factor latest technologies


4 0.77 12 1.21 25 1.15 27 1.02 Reliable drain trap with no compressed air loss
5 0.86 13 1.24 32 1.00 32 1.00 Outlet temperature control function(Option)
6 0.93 14 1.27 35 0.85 37 0.8 Low differential pressure minimizing compressed
7 1.00 40 0.7 40 0.75
8 1.05 45 0.6 45 0.65 air loss
9 1.1 50 0.5 50 0.5 Maximize efficiency by using high-efficiency
10 1.14
condenser
11 1.18
Monitoring of air dryer by mobile phone
(some products)

6 | Global Standard Air / Gas Global Standard Air / Gas | 6


PHL
Heatless desiccant air dryer
OPTION
DEW POINT
OVER SIZE
METTER

DESIGN DATA FLOW DIAGRAM


SUS HIGH
MATERIAL PRESSUPE

Fluid : Compressed Air Dew Point : -40℃ @ ATM

Ref. Air Dryers


Inlet air conditions : ISO 8573.1:2010 Class 4.4.1

Inlet Pressure 7barg


Inlet Temperature 38℃
Design Pressure 9.7barg
Ambient Temperature 32℃
Differential Pressure 0.2bar
PRODUCT IMAGE

Desiccant Air Dryers


Regeneration Air

Compressed Air

Technical Specification
Power Amount of
Connection Flow rate Power supply Dimension (mm) Weight
Model consumption adsorbent
A ㎥/hr W V / Ph / Hz A B C Kg/2Tower kg
5 PT 15A 10 500 225 745 3 23
S 10 PT 15A 20 500 225 745 4 27
H
L 15 PT 15A 25 500 225 745 7 36
20 PT 15A 35 500 225 745 10 46
25 PT 20A 45 840 305 1010 15 102

Accessories
50 PT 20A 85 840 305 1535 25 136
75 PT 20A 130 1150 435 1665 40 160
100 PT 25A 170 1150 435 1870 50 250
125 PT 25A 215 1150 435 1870 60 260
150 PT 25A 255 1150 435 1870 65 272
200 PT 40A 340 1150 485 1865 90 306
50 220 / 1 / 60
250 PT 40A 425 1270 550 1800 125 405
P 350 PT 40A 595 1270 585 1870 175 473
H
L 500 PT 50A 870 1400 670 2090 250 650
650 PT 50A 1110 1400 670 2350 325 720
800 FLG. 65A 1360 1500 1100 2600 400 900
1000 FLG. 80A 1700 1500 1100 2610 500 1125
1200 FLG. 80A 2040 1800 940 2390 595 1305
1400 FLG. 80A 2380 1800 940 2750 700 1575

Gas Equipments
1600 FLG. 100A 2720 2000 1000 2900 800 1755
1800 FLG. 100A 3060 2000 1000 2900 860 2205
2000 FLG. 100A 3400 2000 1110 2900 1000 2340

References
■ Even under – 40℃ dew point units can be custom-made.
■ ASME or standards other than KS can be custom-made.
■ Products with a design pressure of 9.8 barg or higher are custom-made.
■ Customized-engineering products without this table are also available.
Specifications are subject to change without notice to improve product performance and quality.
Useful Information

FACTOR CHARACTERISTICS DIMENSION


Controllers capable of controlling process time
Inlet Pressure(barg) Inlet Temperature(℃) Easy maintenance through manual operation of controller that

Press Factor Temp Factor can control process time


Use high-quality adsorbent with the proven performance of air
4 0.6 25 1.12
5 0.72
filter/safety valve for control
30 1.05
Use high-quality automatic valves with proven performance
6 0.87 38 1.00
Minimize noise with high-quality silencers
7 1.00 45 0.7
Up to -100'C low dew point available(optional)
8 1.1 50 0.55
9 1.15

Global Standard Air / Gas | 7


PEH
Heated purge desiccant air dryer
OPTION
DEW POINT
OVER SIZE
METTER

DESIGN DATA FLOW DIAGRAM


SUS HIGH
MATERIAL PRESSUPE

Fluid : Compressed Air Dew Point : -40 ℃ @ ATM


Inlet air conditions : ISO 8573.1:2010 Class 4.4.1 Dry Air

Inlet Pressure 7barg


Inlet Temperature 38℃
Design Pressure 9.7 barg
Design Temperature) 250℃
Differential Pressure 0.2 bar
PRODUCT IMAGE

Regeneration Air

Compressed Air

Wet Air

Technical Specification
Amount
Connection Flow rate Heater Power supply Dimension (mm) Weight
Model of adsorbent
A ㎥/hr kW V / Ph / Hz A B C kg/2Tower kg
100 FLG. 25A 150 3 870 870 1930 90 300
150 FLG. 40A 250 3.4 970 900 1890 110 350
200 FLG. 40A 370 4 970 900 1990 170 700
285 FLG. 40A 495 4.5 1150 1000 2240 210 750
350 FLG. 50A 660 7.5 1150 1000 2540 280 900
430 FLG. 50A 870 9 1150 1000 2570 390 1000
560 FLG. 65A 1050 10 1250 1100 2670 460 1300
720 FLG. 65A 1380 12 1450 1100 2705 520 1500
900 FLG. 80A 1680 15 1450 1100 2710 700 1800
P 1100 FLG. 80A 1950 18 1600 1400 2750 860 2200
E 1350 FLG. 80A 2280 20.4 380 / 3 / 60 1700 1400 2850 1000 2600
H
1550 FLG. 100A 2950 28.5 1900 1400 2950 1050 3000
2100 FLG. 100A 3700 33 2400 1400 2990 1560 4200
2500 FLG. 125A 4550 36 2500 1600 3250 2000 4800
3000 FLG. 150A 5400 44 2500 1600 3250 2100 5200
4100 FLG. 150A 6600 56 3000 2000 3250 2900 6000
4500 FLG. 150A 7500 62 3000 2000 3250 3200 6300
5400 FLG. 150A 8500 70 3200 2000 3300 3780 6800
6000 FLG. 200A 10500 85 3900 2300 3430 4200 7500
7000 FLG. 200A 12000 100 4600 2130 3150 4900 9000
9000 FLG. 250A 15000 110 5000 2500 3150 6400 10000

References
■ Even under – 40℃ dew point units can be custom-made.
■ ASME or standards other than KS can be custom-made.
■ Products with a design pressure of 9.8 barg or higher are custom-made.
■ Customized-engineering products without this table are also available.
■ Specifications are subject to change without notice to improve product performance and quality.

FACTOR CHARACTERISTICS DIMENSION

Inlet Pressure(barg) Inlet Temperature(℃)  sing the pan/dual check Valve


U Parker pneumatic solenoid valve
Control air filter High-quality silencer attachment
Press Factor Temp Factor Minimize purge air loss Reliable automatic valve
4 0.60 25 1.12 Safety valve An electric heater
5 0.72 30 1.05 High-quality pressure gauges are Efficient compressed air distribution
6 0.87 38 1.00 applied system
7 1.00 45 0.7 PLC and touch panel
8 1.1 50 0.55 Use of high-quality adsorbent
9 1.15

8 | Global Standard Air / Gas


PEHB
Heated blower purge desiccant air dryer
OPTION
DEW POINT
OVER SIZE
METTER

DESIGN DATA FLOW DIAGRAM


SUS HIGH
MATERIAL PRESSUPE

Fluid : Compressed Air Dew Point : -40 ℃ @ ATM

Ref. Air Dryers


Inlet air conditions : ISO 8573.1:2010 Class 4.4.1

Inlet Pressure 7barg


Inlet Temperature 38℃
Design Pressure 9.7barg
Design Temperature 250 ℃
Differential Pressure 0.2 bar
PRODUCT IMAGE

Regeneration Air

Compressed Air

Desiccant Air Dryers


Technical Specification
Amount
Connection Flow rate Heater Blower Power supply Dimension (mm) Weight
Model of adsorbent
A ㎥/hr kW kW V / Ph / Hz A B C kg/2Tower kg
150 FLG. 40A 250 3.4 1.5 970 1100 1890 110 500
200 FLG. 40A 370 4 1.75 970 1100 1990 170 650
285 FLG. 40A 495 4.5 1.75 1150 1200 2240 210 900
350 FLG. 50A 660 7.5 1.75 1150 1200 2540 280 1000

Accessories
430 FLG. 50A 870 9 1.75 1150 1200 2570 390 1200
560 FLG. 65A 1050 10 3 1250 1300 2670 460 1500
720 FLG. 65A 1380 12 3 1450 1400 2700 520 1800
900 FLG. 80A 1680 15 3 1450 1400 2705 700 2000
P 1100 FLG. 80A 1950 18 6.3 1700 1600 2750 860 2400
E
1350 FLG. 80A 2280 20.4 6.3 380 / 3 / 60 1700 1700 2850 1000 2900
H
B 1550 FLG. 100A 2950 28.5 7.5 1900 1700 2950 1050 3400
2100 FLG. 100A 3700 33 9 2400 1800 2990 1560 4000
3000 FLG. 150A 5400 44 13 2500 1950 3250 2100 4800
4100 FLG. 150A 6600 56 15 3200 2300 3250 2900 6000
4500 FLG. 150A 7500 62 15 3200 2400 3250 3200 6500
5400 FLG. 150A 8500 70 20 3200 2500 3300 3780 7300

Gas Equipments
6000 FLG. 200A 10500 85 22 3400 2500 3430 4200 8100
7000 FLG. 200A 12000 100 27 3600 2500 3430 4900 10300
9000 FLG. 250A 15000 110 30 4000 3000 3430 6400 12300

References
■ Even under – 40℃ dew point units can be custom-made.
■ ASME or standards other than KS can be custom-made.
■ Products with a design pressure of 9.8 barg or higherare custom-made.
■ Customized-engineering products without this table are also available.
■ Specifications are subject to change without notice to improve product performance and quality.
Useful Information

FACTOR CHARACTERISTICS DIMENSION


Using the pan/dual check valve Electric heater
Inlet Pressure(barg) Inlet Temperature(℃)
Control air filter High-quality ring blower
Press Factor Temp Factor Minimize purge air loss High-quality silencer attachment
4 0.6 25 1.12 Safety valve Reliable automatic valve
Use of high-quality adsorbent Efficient compressed air distribution
5 0.72 30 1.05
Using a high-quality pressure/ system
6 0.87 38 1.00
temperature gauge Parker pneumatic solenoid valve
7 1.00 45 0.7
PLC and touch panel
8 1.1 50 0.55
9 1.15

Global Standard Air / Gas | 9


ZEHB
Zero purge loss desiccant air dryer
OPTION
DEW POINT
OVER SIZE
METTER

DESIGN DATA FLOW DIAGRAM


SUS HIGH
MATERIAL PRESSUPE

Fluid : Compressed Air Dew Point : -40 ℃ @ ATM


Inlet air conditions : ISO 8573.1:2010 Class 4.4.1

Inlet Pressure 7barg


Inlet Temperature 38℃
Design Pressure 9.7 barg
Design Temperature 250℃
Differential Pressure 0.2 bar
PRODUCT IMAGE

Regeneration Air

Compressed Air

Technical Specification
Amount
Connection Flow rate Air compressor Heater Blower Power supply Dimension (mm) Weight
Model of absorbent

A ㎥/hr HP kW kW V / Ph / Hz A B C kg/2Tower kg
430 FLG. 40A 680 75 8.5 1.5 1900 900 2030 324 1440
560 FLG. 50A 890 100 11.0 1.75 2100 1000 2230 406 1700
720 FLG. 50A 1140 130 14.0 2.55 2100 1000 2230 474 2060
900 FLG. 65A 1430 150 17.5 2.55 2600 1250 2400 592 2200
1100 FLG. 65A 1740 175 21.5 4.5 2600 1250 2400 755 2470
1350 FLG. 80A 2140 200 26.5 4.5 2600 1670 2330 943 2690
1550 FLG. 80A 2450 250 30.0 4.5 2600 1710 2330 1,022 3100
220V/380V
2100 FLG. 100A 3320 300 41.0 8.6 3100 1650 2445 1,384 4090
Z 440V
E 2600 FLG. 100A 4120 400 50.5 8.6 3400 1970 2290 1,848 4700
H 3000 FLG. 125A 4750 500 58.5 12.6 1Ph 3550 1970 2290 1,980 5860
B
3400 FLG. 125A 5380 600 66.0 12.6 3650 2140 2530 2,272 7400
50/60Hz
4100 FLG. 125A 6490 700 80.0 15.3 3650 2180 2530 2,707 8200
4500 FLG. 150A 7120 800 87.5 22.7 5700 2100 2960 3,055 9600
5400 FLG. 150A 8550 900 105.0 22.7 5700 2100 2960 3,566 11400
6000 FLG. 150A 9500 1000 117.0 22.7 6000 2150 3000 4,052 12300
7000 FLG. 200A 11080 1200 136.0 25.2 7000 2200 3500 4,621 13500
8000 FLG. 200A 12660 1300 155.5 30.6 7000 2500 3700 5,279 14700
9000 FLG. 200A 14520 1600 175.0 37.0 7000 2500 3700 5,942 15600

References
■ Even under – 40℃ dew point units can be custom-made.
■ ASME or standards other than KS can be custom-made.
■ Products with a design pressure of 9.8 barg or higher are custom-made.
■ Customized-engineering products without this table are also available.
■ Specifications are subject to change without notice to improve product performance and quality.

FACTOR CHARACTERISTICS DIMENSION


Using the pan/dual check Valve High quality ring blower
Inlet Pressure(barg) Inlet Temperature(℃)
Minimize purge air loss An electric heater
Press Factor Temp Factor
Safety valve Parker Pneumatic Solenoid Valve
Control air filter High quality ring blower
4 0.60 25 1.12
Use of high-quality adsorbent Power regulator(if applicable)
5 0.72 30 1.05 Using a high-quality pressure/ Reliable automatic valve
6 0.87 38 1.00 Efficient compressed air distribution
temperature gauge
7 1.00 45 0.7
PLC and touch panel System
8 1.1 50 0.55 High-quality silencer attachment
9 1.15

10 | Global Standard Air / Gas


PMD
Membrane Dryer
OPTION

DESIGN DATA FLOW DIAGRAM


Fluid : Compressed Air Dew Point : -20℃ @ ATM

Ref. Air Dryers


Inlet Pressure 7barg Inlet Temperature 25℃ ~ 30℃
Design Pressure 9.7barg Max. Inlet Temperature 60℃
Differential Pressure 0.2bar Purge Flow Rate 10% ~ 20%

Moist compressed air passes through the hollow fiber module, allowing fast diffusion
and rapid passage of moisture to escape from the hollow fiber, removing moisture from
the compressed air and discharging it through the silencer with purge air
Moisture - Hydrogen - Helium - Carbon dioxide - Oxygen - Argon - Carbon
PRODUCT IMAGE

Fast passing speed ← → Slow passing speed


Hollow fiber
Made of Polysulfone, a highly functional engineering plastic, with a hollow tube-shaped thin fiber made from polymers.

1 Wet compressed air is introduced through the inlet cap.


2 Dry moist compressed air as it passes through the hollow fiber module installed in
the housing.

Desiccant Air Dryers


3 Drain the dried air through the outlet cap.
A Part of the dried compressed air (approximately 20%) flows along the hole machined in
the outlet cap through the exterior of the hollow installed in the housing and is discharged
through the silencer along with the moisture penetrated into the surface of the hollow.
B You can adjust the purge air volume with the needle valve installed in the outlet cap.

Connection Air compressor Flow rate Dimension (mm) Weight


Model
A HP ℓ/min A B kg
PMD-135 PT 15A 1 135 220 75 1.0
PMD-240 PT 15A 2 240 360 75 1.3
PMD-370 PT 15A 3 370 470 75 1.6
PMD-600 PT 15A 5 600 590 75 2.0

1. All specification can be changed to improve the quality without notice.


2. Exceptional models of this brochure are optional.(Package)

Accessories
How to control the amount of PDM purge
· Refer to the adjustment figure and adjust the six corners of the adjustment valve by rotating them 60 degrees relative to the outlet
cap bolt. Refer to the table below for purge flow rates per 60-degree rotation.

Example) Valve adjustment by the model (20% purge standard)


Purge Angle
Initial marking flow rate(LPM) of rotation(˚)
(shipped locked)

Angle of rotation(˚)
1 rotation = 6 clocks
(60 degrees rotation) Purge flow rate(LPM)

Gas Equipments
A Wet
수분과 compressed
이물질이 제거되지air without
않은 습한removing
압축공기 moisture and foreign substances. If the conditions of use are different, the change in the treatment flow
PMD Recommendation System

rate according to the condition can be multiplied by the number below.


FACTOR

B Clean
수분과 compressed
이물질이 제거된 air 깨끗한
with moisture
압축공기 and foreign substances removed.
Inlet Pressure(barg)

Air Compressor Air Pressure


HTN High-Temperature Air Dryer
Filter for removing HYF particles
HYF oil removal filter *If the PMD135 model is used, the treatment flow rate is
PMD membrane Dryer 135l/min when the inlet pressure is 7barg, and if the inlet

PMD Recommendations Where to USE


pressure is 8.5barg, multiply by the calibration factor of
1.2 to calculate the treatment.
Useful Information

It operates immediately, making it easy to use Low stall instrument air


DIMENSION

High-clean dry air can be produced continuously Pneumatic equipment


It's environmentally friendly Clean air for lab
PMD Features

Installation location restrictions are small Ultra-precise measurement and analysis equipment
Energy consumption is low due to low electricity usage Medical(Dental use)
There is no additional maintenance other than replacing Prevention of Freezing
the shear filter Drying of powder
The highest quality Hosing case was used CDA(Clean Dried Air)

Global Standard Air / Gas | 11


Combination Air Dryer
GCBD Series
OPTION
DEW POINT
OVER SIZE
METTER

DESIGN DATA FLOW DIAGRAM


SUS HIGH
MATERIAL PRESSUPE

Fluid : Compressed Air

Inlet Pressure 7barg


Inlet Temperature 38℃
Design Pressure 9.7 barg
Dew Point -40℃
Differential Pressure 0.4 bar
PRODUCT IMAGE

Combination Air Dryer?


Our GCBD combination air dryer is composed of a specially designed refrigerated air dryer and an adsorption air dryer effectively removing moisture
contained in compressed air. It is a high-efficiency, low-cost, eco-friendly dryer that reduces operating costs by increasing product performance and
efficiency by configuring the system to operate in a complementary manner rather than installing each product individually.

Technical Specification

No. Description Specification Unit Remark

1 Air Flow Capacity 2,800 ~ 20,000 ㎥/hr

2 Inlet Air Pressure 7 barg


Design
3 Conditions Inlet Air Temperature 38 ℃

4 Total Pressure Drop 0.4 bar

Combination Ref. Air Dryer GCRD Series -


Combination
5 Water Separator HYS Series -
Air Dryer Composition
Combination Desiccant Air Dryer GCBD Series -

Summer Season 4 ~ 10 ℃
6 Outlet Dew Point
Winter Season -40 ℃

Energy saving technology


GSA's combination air dryer can save energy by up to approximately 70% compared to using a heatless regenerative adsorption dryer alone, and up to 55%
compared to a heated regenerative adsorption dryer.

■ The regenerative heater of the adsorption dryer consumes less electricity, and in the case of the zero purge type, there is no regenerative air
consumption, reducing operating costs.
■ The adsorbent replacement cycle is long and the amount of adsorbent is small, reducing costs when replacing the adsorbent.
■ Stable dew point guaranteed by combination with specially designed refrigerated dryer.

GSA's combination air dryer is the best solution for realizing carbon neutrality by saving energy and increasing efficiency.

12 | Global Standard Air / Gas


HYF
Compressed air filter
OPTION
DPI
OVER SIZE

DESIGN DATA FLOW DIAGRAM


SUS HIGH
MATERIAL PRESSUPE

Fluid : Compressed Air

Ref. Air Dryers


Inlet Pressure 7barg
Max. Inlet Temperature 60℃
Design Pressure 9.7 barg
Differential Pressure 0.2 bar
Min. Inlet Temperature 5℃
1. Internal Core Layer

2. Filtering Layer
PRODUCT IMAGE

3. Main Layer

4. Coalescing Layer

Desiccant Air Dryers


5. Drain Layer)

Filter Elements
Differential pressure indicator
Particle Oil Removal Max operating Temp Differential Pressure (barg) Elements
Model (replacement of element)
removal (@ 20’C)
℃ Dry Wet DPI Color Month Colour Material
40 40 Micron - 0.05 0.15 White Polyethylene
65
5 5 Micron - 0.05 0.15 White Polyethylene
H 1 1 Micron 1 ppm 0.15 0.3 Red Borosilicate
6
Y RED
E 0.1 1 Micron 0.1 ppm 0.15 0.3 White Borosilicate
54
0.01 1 Micron 0.01 ppm 0.15 0.3 Yellow Borosilicate
0.003 - 0.003 ppm 0.1 0.2 White Activated Carbon

Accessories
Filter
Flow rate Max Pressure Connection Quantity of element Dimension Weight
Model
㎥/min CFM barg A EA (A x B) mm kg
15AN 0.8 28 PT 15A 1 85 x 185 0.8
20AN 1.7 60 PT 20A 1 85 x 225 1
25AN 3.4 120 13 PT 25A 1 105 x 330 1.9
40AN 10 353 PT 40A 1 165 x 440 5.5
50AN 14 494 PT 50A 1 165 x 540 6.5
H 65A 28 989 FLG. 65A 2 550 x 1143 88
Y
F 80A 42 1483 FLG. 80A 3 550 x 1143 103

Gas Equipments
100A 70 2472 FLG. 100A 5 600 x 1180 120
125A 84 2966 9.7 FLG. 125A 6 700 x 1251 170
150A 112 3955 FLG. 150A 8 700 x 1251 180
200A 196 6922 FLG. 200A 11 1000 x 2367 300
250A 330 11654 FLG. 250A 19 1200 x 2705 400

High-pressure filter
Flow rate Max Pressure Connection Quantity of element Dimension Weight
Model
㎥/min CFM barg A EA (A x B) mm kg
15H 1 35 PT 15A 1 106 x 340 17

H 20H 1.9 67 PT 20A 1 106 x 390 19


Y 25H 3.4 120 35.0 PT 25A 1 106 x 510 21
Useful Information

F 40H 10 353 PT 40A 1 144 x 700 25


50H 14 494 PT 50A 1 185 x 925 28

References
■ Special pressure or stainless steel is custom made.
■ The filter support is a standard for HYF-125A or bigger models.
■ HYE - XX - 50A (bolt type) is applied to the element of HYF-65A or higher, and the quantity varies depending on the model,
so please check the quantity before ordering.
■ Filter nomenclature
- Filter Model : HYF-40-15AN(filter - filtering rate - connection diameter)
- Element Model : HYE-40-15AN(Element - filtering rate - Connection Diameter)

Global Standard Air / Gas | 13


GS
Air Receiver Tank
OPTION
DRAIN
OVER SIZE
TRAP

DESIGN DATA CALCULATION FORMULA


SUS HIGH
MATERIAL PRESSUPE

Fluid : Compressed Air

Air Receiver Tank Calculation Formula


Inlet Pressure 7barg Design Temperature 100℃

V Receiver tank capacity m3 P1 Compressor oulet pressure kg/cm2(a)

t Interval in second to use over flowed P2 Receiver tank pressure kg/cm2(a)


compressed air min
P3 Receiver outlet pressure kg/cm2(a)
PRODUCT IMAGE

Q1 Required air volume m3

Q2 Compressor oulet air volume m3

V = { P1 x (Q1 - Q2) x t } / ( P2 - P3 )

Technical Specification
Capacity Connection O.D. Height (H) Anchor Hole Weight
Model
m3 A mm mm mm kg
0003A 0.3 25A 609 1,450 16 150

0005 0.5 40A 660 1,770 16 210

001 1 50A 916 1,908 16 400

0015 1.5 50A 1,013 2,246 16 560

002 2 65A 1,150 2,358 20 832

0025 2.5 80A 1,284 2,559 20 970

003 3 80A 1,299 2,720 20 1,300

G 0042 4 100A 1,489 2,820 20 1,500


S 005 5 100A 1,504 3,437 20 1,750

0061 6 150A 1,626 3,460 22 2,500

007 7 150A 1,626 4,078 22 2,700

008 8 150A 1,606 4,580 22 3,000

010 10 200A 1,878 4,287 24 3,100

012 12 200A 1,960 4,657 24 3,800

013 13 200A 2,134 4,300 24 4,000

016 16 250A 2,480 4,025 24 5,000

References
■ ASME specifications other than KS specifications can also be custom-made.
■ High-pressure products with high design pressure can also be custom-made.
■ Customized-engineering products without this table are also available.
■ Specifications are subject to change without notice to improve product performance and quality.

Need for receiver tanks


■ Reduce management costs of air compressors by reducing the load and no load cycles of air compressors.
■ By temporarily storing hot air discharged from the air compressor and naturally cooling the compressed air, condensate
is discharged and the load on the rear end facility is reduced.
■ Minimize pressure fluctuations that affect the production process or quality.
■ Securing the stability of the production process according to emergency situations.

14 | Global Standard Air / Gas


HAD
Condensate Drain and others

Condensate discharge device(Drain)


A Condensate discharge device is essential apparatus designed to prevent system failure, extend the life of the equipment and

Ref. Air Dryers


prevent a product defect by periodically discharging condensate which is produced during dehumidification of
compressed air.

HAD-10 HAD-20 HAD-100


HAD-30 HAD-100 EDV-15T / 40T DM Series

Desiccant Air Dryers


TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA
Operating Temp 2~60℃ Operating Temp 2~60℃ Operating Temp 2~60℃ Operating Temp 2~80℃
Operating Press 0.5~16barg Operating Press 0.5~16barg Operating Press 0~15barg Operating Press 0.8~16barg
Type Ball Type Disk Type Elec. Timer Type Level Sensing
Inlet Connection PT 15A Inlet Connection PT 15A Inlet Connection PT 15A Inlet Connection PT 15A
Outlet Connection PT 6A Outlet Connection PT 15A Outlet Connection PT 15A Outlet Connection PT 10A
Dimension(D x H, mm) 81Φ x 132 Dimension(D x H, mm) 86Φ x 175 Dimension(D x L x H, mm) 95 x 90 x 102 Dimension(D x L x H, mm) 165 x 80 x 155
Weight 0.5 kg Weight 0.8 kg Weight 0.6 kg Weight 1.3 kg

Differential Pressure Gauge


Indicate differential pressure by detecting pressure at the inlet and outlet of the filter and allows a user to check when a filter
element should be replaced.

HDI30

Accessories
TECHNICAL DATA
Operating Temp 2 ~ 60 ℃
Operating Press Max. 16 barg
Green Area 0 ~ 0.6 bar

Gas Equipments
Red Area 0.6 ~ 0.9 bar
Mounting Bolt M5
Dimension(D x L x H , mm) 40 x 40 x 35
Weight 0.03 kg

Desiccant
A desiccant used includes carbon molecular sieve (CMS) and zeolite molecular sieve (ZMS) for nitrogen and oxygen production,
including activated alumina needed to dehumidify compressed air.

Activated Alumina Carbon Molecular Sieve Zeolite Molecular Sieve


Useful Information

PACKING PACKING PACKING


Desiccant Size [mm] 4~6 Desiccant Size [mm] Pellet Desiccant Size [mm] 3A/4A/5A/13X
Small Packing 20 kg Small Packing 40 kg Small Packing 40 kg
Large Packing 1000 kg Large Packing 137 kg Large Packing 120 kg

Global Standard Air / Gas | 15


N2 PSA
Nitrogen Generator
OPTION
FLOW TOUCH
METER SCREEN

DESIGN DATA FLOW DIAGRAM


O2 HIGH
ANALYSOR PRESSUPE

Fluid : Compressed Air

Inlet Pressure 7barg


Design Pressure 9.7barg Inlet Temperature 5℃ ~ 45℃
Comp. Air Quality ISO8573-1 class 1-4-1 Ambient Temperature 20℃
Performance ±5%
PRODUCT IMAGE

Technical Specification
Nitrogen Capacity (m³/h)
95% 9.3 16.2 23.6 37.9 55.0 67.4 82.7 100.4 145.8 228.5 301.5 409.3 479.8 648.3
(1.5N)
97% 8.6 14.9 21.7 34.9 50.7 62.1 76.1 92.5 134.2 210.4 277.5 376.8 441.7 596.8
(1.7N)
98% 8.1 14.2 20.7 33.2 48.3 59.1 72.4 88.0 127.6 200.14 264.0 358.4 420.1 567.7
(1.8N)
99% 7.4 12.9 18.8 30.2 43.9 53.7 65.9 80.0 116.1 182.0 240.1 326.0 382.1 516.3
(2N)
99.50% 6.7 11.7 17.1 27.5 40.0 48.9 60.0 72.9 105.8 165.8 218.7 297.0 348.1 470.4
(2.5N)
99.90% 5.4 9.5 13.8 22.1 32.2 39.4 48.4 58.7 85.2 133.6 176.3 239.4 280.6 379.1
(3N)
99.95% 4.6 8.0 11.6 18.6 27.0 33.1 40.6 49.3 71.5 112.2 147.9 200.9 235.5 318.2
(3.5N)
99.99% 3.8 6.7 9.7 15.6 22.7 27.7 34.0 41.3 60.0 94.1 124.1 168.5 197.5 266.8
(4N)
99.999% 2.6 4.6 6.7 10.8 15.7 19.2 23.5 28.6 41.5 65.1 85.9 116.6 136.7 184.7
(5N)

Dimensions (mm)
L 2,200 2,600 2,800 3,000 3,500 3,600 3,700 3,800 4,100 4,900 5,300 6,000 6,200 6,400
W 1,300 1,450 1,750 2,100 2,300 2,450 2,450 2,550 2,700 3,300 3,600 4,100 4,400 4,600
H 2,050 2,050 2,050 2,100 2,100 2,100 2,300 2,350 2,650 2,700 2,800 3,200 3,250 3,300

Required Compressed Air (m³/h)


Capa. 19 33 48 77 112 137 168 204 296 464 612 831 974 1,316

References
■ Models under membrane type as well as PSA are also customizable.
■ Models under ASME in addition to KS are also customizable.
■ Large models bigger than those stated in the specifications above
are also customizable.
■ The Specifications are subject to changes without notice for product
improvement.

Nomenclature
GNG - XX - XXX

Purity
Product Flow Rate

16 | Global Standard Air / Gas


O2 PSA
Oxygen Generators
OPTION
FLOW TOUCH
METER SCREEN

DESIGN DATA FLOW DIAGRAM


O2 HIGH
ANALYSOR PRESSUPE

Fluid : Compressed Air

Ref. Air Dryers


Inlet Pressure 7barg
Design Pressure 9.7barg Inlet Temperature 5℃ ~ 45 ℃
Comp. Air Quality ISO8573-1 class 1-4-1 Ambient Temperature 20℃
Performance ±5%
PRODUCT IMAGE

Desiccant Air Dryers


Technical Specification
Oxygen Capacity (m³/h)

90% 1.7 2.9 4.3 6.8 9.9 12.1 14.9 18.1 26.2 41.1 54.2 73.7 86.3 116.6

93% 1.5 2.7 3.9 6.3 9.1 11.1 13.6 16.6 24.0 37.7 49.7 67.5 79.1 106.9

95% 1.4 2.5 3.6 5.8 8.4 10.3 12.6 15.3 22.2 34.8 46.0 62.4 73.2 98.9

Dimensions (mm)

Accessories
L 2,100 2,400 2,650 2,850 3,300 3,400 3,550 3,650 4,000 4,700 5,100 5,800 6,000 6,200

W 1,200 1,350 1,600 1,950 2,150 2,350 2,400 2,500 2,600 3,100 3,500 4,000 4,250 4,500

H 2,000 2,050 2,100 2,100 2,100 2,100 2,200 2,230 2,540 2,600 2,700 3,000 3,150 3,300

Required Compressed Air (m³/h)

Capa. 19 33 48 77 112 137 168 204 296 464 612 831 974 1,316

Components
Power consumption (kW)

Air Comp. 4 5.5 7.5 11 15 18 22 27 37 55 75 90 110 150

Ref. Dryer 0.46 0.62 0.68 0.72 1.3 1.3 1.6 1.6 2.1 2.3 3.0 4.6 5.1 8.5

Gas Equipments
Oxy. Gener. 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

Total 5.46 7.12 9.18 12.72 17.3 20.3 24.6 29.6 40.1 58.3 79.0 95.6 116.1 159.5

References
■ Models under VSA as well as PSA are also customizable.
■ Models under ASME in addition to KS are also customizable.
■ Large models bigger than those stated in the specification
above are also customizable.
■ The specifications are subject to changes without notice for
product improvement.
Useful Information

Nomenclature H

GOG - XX - XXX

Purity
W

Product Flow Rate

Global Standard Air / Gas | 17


H2 Dryer
Hydrogen dryer/DEOXO equipment
OPTION
FLOW TOUCH
METER SCREEN

DESIGN DATA FLOW DIAGRAM


HIGH
DETEC TOR
PRESSUPE

Fluid : Hydrogen

Inlet Pressure 7barg


Inlet Temperature 40℃
Design Pressure 9.7barg
Design Temperature 250℃
Max.Pressure Drop 0.4bar
PRODUCT IMAGE

수소 드라이어의 구성
수소 드라이어의 장치 시스템 구성
Utilization and Installation of Hydrogen Dryer
As interest and demand for eco-friendly energy resources are 물 배출구
water outlet H2
H2가스
Gas출구
Exit
gradually increasing due to greenhouse gas problems such 흡착탑-A
Adsorption Top-A 재생 쿨러 Cooler
Recycled 안전 밸브valve
Safety
as carbon dioxide and climate change, hydrogen is attracting
H2
H2가스
Gas입구
entrance 흡착탑-B
Absorption TopB 방폭 배선함 proof wiring box
Explosion 방폭 제어함
attention as a new energy resource to replace fossil fuels.
Hydrogen is the ultimate eco-friendly energy source and
is a clean and infinite resource that does not generate any
byproducts other than water, and its application fields have
recently been expanding, including hydrogen fuel cells and
automobiles.As hydrogen is attracting attention as an alternative
energy source, interest in how to produce hydrogen is also
growing. The most commonly used methods of hydrogen
production include the use of by-product hydrogen separately
generated by petrochemical processes, and the natural gas
reforming method that decomposes natural gas into high-
temperature/high-pressure water vapor to produce hydrogen.
The natural gas reforming method is the most widely used
method and has the advantage of producing hydrogen at a
low cost. Finally, there is a water electrolysis method that
electrolyzes water to get hydrogen.Since the purity of hydrogen
has a significant impact on the performance of fuel cells,
refining techniques for obtaining high purity hydrogen are very
important. A hydrogen dryer is a device that purifies hydrogen
by removing oxygen in hydrogen in the form of moisture using a
Pd (palladium) catalyst and an adsorbent.

Utilization and Installation


of Hydrogen Dryer
■ Purification of hydrogen produced from hydrogen PSA.
■ Purification of hydrogen produced by water electrolysis facilities.
■ Onsite hydrogen supply line to purify hydrogen gas. 물 배출 밸브
Water drain valve 예냉 쿨러
A pre-cooled cooler 재생 히터
Regenerative heater
■ Requires supply of cooling water and hot steam.
냉각수 출구outlet
Coolant 유량제어 밸브 valve
Flow control 예열 히터
Preheating heater
■ Alternative design for explosion-proof electric heaters instead of
hot steam. 냉각수 입구
Coolant inlet 촉매탑
Catalyst top

Characteristics of GSA Hydrogen Dryer


www.gsadryer.com
■ Use of high-quality adsorbents and catalysts.
■ Excellent operating performance using reliable valves and instruments.
■ Specially designed explosion-proof electric heaters are available (system configuration is possible without the supply of preheating
heaters and steam used in regenerative heaters)
■ Water is discharged smoothly by using a level switch consisting of five stages and hydrogen leakage is prevented due to failure, etc.
■ Accurate system control through various instruments such as Control Valve and Flow Meter.
■ Design various design codes (other than KS/ASME/GOST/DOSH)
■ High-efficiency heat exchangers are applied to pre-coolers and regeneration coolers.
■ Designed to meet user needs.

18 | Global Standard Air / Gas


CO2 Removal System
Carbon dioxide removal equipment
OPTION
FLOW TOUCH
METER SCREEN

DESIGN DATA FLOW DIAGRAM


CO2 HIGH
ANALYZER PRESSUPE

Fluid : Compressed Air

Ref. Air Dryers


Inlet Pressure 7barg
Inlet Temperature 38℃
Design Press 9.7barg
Design Temperature 250℃
Differential Pressure 0.2bar
PRODUCT IMAGE

Desiccant Air Dryers


Regeneration Air

Compressed Air

Technical Specification
No. Description Specification Unit

1 Air Flow Capacity 160 ~ 15,000 m³/h

2 Inlet Feed Air Pressure 5 ~ 8.5 barg

3 Conditions Feed Air Temperature ≤ 38 ℃

Accessories
4 Feed Air CO2 Purity ≤ 450 ppm

5 Outlet Product Air Dew Point ≤ -65 ℃

6 Conditions Product Air CO2 Purity ≤5 ppm

Adsorption 4 hr
Standard
7 Heating Regeneration 2.5 hr
Process Time
Cooling Regeneration 1.5 hr

Regeneration Temperature 180 ~ 230 ℃


8
Conditions Pressure 0.2 ~ 0.3 barg

9 Differential Pressure 0.2 bar

CO2 Removal equipment necessity Gas Equipments


Compressed air contains nitrogen, oxygen, moisture, and CO2. This facility is intended to remove moisture and CO2 contained in compressed air and can
be used in various industrial fields, including semiconductors and fuel cells. The adsorption tower of this facility contains activated alumina to remove
moisture in the compressed air, and the upper part is filled with Molecular Sieves to adsorb a small amount of moisture and CO2 to effectively remove
moisture and CO2 in the compressed air. Normally, dew points below -65℃ and CO2 below 5 ppm are removed. Commonly used compressed air is not
a big problem even if it contains CO2 components. However, some processes require ultra-dry air without CO2. If moisture or CO2 components are not
removed, it will cause serious quality problems in the process or in the final product.

Principle of operation of CO2 removal system


Useful Information

Operation of the CO2 removal unit is performed automatically according to the sequence of PLCs or mycoms. Compressed air containing moisture and
CO2 flows into the lower part of the two adsorption towers under the adsorption process and then through the adsorbate layer and into the upper part.
In the process of moving up, the difference in diffusion rate due to the pores of the adsorbent separates moisture and CO2 from compressed air and
supplies dry compressed air from which CO2 has been removed. While one of the two adsorption towers is undergoing the adsorption process, the other
is subjected to a regenerative process. The regeneration process consists of a heating process and a cooling process, and the heating process uses
high-temperature air heated by an electric heater to adsorbate moisture and CO2 components adsorbed on the adsorbent and then release them to the
atmosphere. The cooling process is a regenerative process that cools the heated adsorbent to achieve good adsorption. When the heating and cooling
regeneration processes are completed, a dynamic pressure process is performed to raise the regeneration tower to the same pressure as the supply
pressure. After the dynamic pressure process is completed, the two adsorption towers are switched and the adsorption tower that has undergone the
adsorption process is subjected to a regeneration process, and the adsorption tower that has undergone the regeneration process is subjected to an
adsorption process. This series of processes proceed automatically in a given sequence and continues to supply dry air with CO2 removed.

Global Standard Air / Gas | 19


Gas Equipment
Gas purifier and gas separation facilities

High purity gas and ultra purity gas


High purity gas is used in various fields such as the semiconductor industry, petrochemical, metal industry, experiments
and research. In particular, high-purity gases in the production sector, including semiconductors and displays, are critical to
maintaining the properties and quality of products.
General industrial gases are not completely removed from the manufacturing process and may be contaminated by impurities
during transportation or storage.

The Necessity of High-Purity Purification Equipment


It is necessary to refine low-purity gases to provide the desired purity gas in various fields requiring high purity gas.
Continuous use of high-purity gas is economical enough because it does not cause problems due to insufficient supply or
delayed delivery as well as the purchase cost spent.

N2 Purifier O2 Purifier CH4 Purifier


Supplies high-purity nitrogen whose impu- Supply of high purity oxygen by removing Refining facilities for the use of methane as
rity concentration(10ppm or above) CO2, CO components, etc. to stored oxygen fuel by removing large amounts of impuri-
by using Pd catalyst and adsorbent to reduce ties, such as nitrogen and carbon dioxide,
■ High-pressure nitrogen refining facilities the impurity concentration of 10 ppm or less from natural gas, which is a major source of
■ A low-pressure nitrogen refining facility to 10 ppm or less. methane.
■ High-pressure oxygen refining facilities
■ Low-pressure oxygen refining facilities

CO2 Removal system H2 Purifier He Low temperature purifier


Equipment for removing CO2 gas from com- Hydrogen gas with an impurity concentra- Refine helium gas with an impurity concen-
pressed air. tion of 10 ppm or more is purified and sup- tration of 10 ppm or more with high purity
plied with high purity hydrogen of 10 ppm or helium of 10 ppb or less using liquefied ni-
less using an adsorbent and heating getter. trogen gas and supply it.
■ Hydrogen Refining Facilities Using Heat-
ing Getter
■ Hydrogen temperature refining facility

Ar Recovery & Purification System Ar Purifier Carbon dioxide(CO2) purification and liquefaction Equipment

After pre-treating the recovered argon, re- Supply of high purity argon by removing N2, Carbon dioxide produced by increased de-
move nitrogen, oxygen, and moisture using O2, CO2, and CO components in stored argon mand for energy and various causes ac-
an adsorbent to supply it. using Pd catalyst and adsorbent to reduce counts for 80% of greenhouse gases, but is
the impurity concentration of 10 ppm or less used in various fields Carbon dioxide (CO2)
to 10 ppb or less. purification and liquefaction facility for re-
moving impurities from collected carbon di-
■ High-pressure argon refining equipment oxide and liquefaction.
■ Low-pressure argon refining facilities

20 | Global Standard Air / Gas


Customer satisfaction Realization
Customer satisfaction is the best value pursued by GSA.
We provide the best products and services in a timely manner and listen to your voice.
All our executives and employees are trusted by our customers through their passionate and
unremitting efforts.

Ref. Air Dryers


Desiccant Air Dryers
The Best Quality Reliability
GSA provides only the highest quality products to ensure that The GSA is challenging the zero defect rate 365 days a year.
customers are always in optimal production at the lowest cost. Because the defect is caused by errors in the production
To maintain the best quality, all our products are manufactured process and production activities, we are making the best
according to international standards and standards. Our effort to find and implement a perfect solution to completely
company produces only the highest quality products by eliminate those errors. The company's efforts toward
periodically checking the quality problems that occur in various perfection have resulted in customer trust in the market.
places and constantly correcting and supplementing the
quality programs and processes.

Accessories
Flexibility The fast delivery
GSA offers maximum flexibility in production as well as GSA optimally manages the production load by applying the
design. For example, if a customer can save on shipping or integrated production management system to the production
shipping costs, we strive from the customer's point of view line to meet the delivery date and shipment deadline that

Gas Equipments
by reducing the height or width of the product so that it can the customer wants. At the same time, for urgent orders
be placed in a regular or HQ container rather than a Flat Rack from customers, customer-oriented production flexibility is
container. used to meet the delivery date.

Thorough
Quality
management

Flexibility Reliability
Customer
Useful Information

satisfaction
Realization
Reasonable Price
GSA provides high-quality products at a reasonable The Fast Reasonable
level as a result of significant cost savings without Delivery Price
compromising quality through mass ordering of materials
and simplificationof manufacturing processes.

Global Standard Air / Gas | 21


Dew point conversion table

Dew Point conversion method


Dew Point measured at Atmospheric pressure condition differs from at system pressure condition.
Each Dew Point can be converted by using the following chart.

At 7.0 bar, pressure dew point -18℃, what is the atmospheric pressure dew point?
Locate the pressure dew point -18℃ on the right side of the chart, draw a horizontal line to the left, and go
down vertically from the point where the pressure intersects the pressure line at 7.0 bar to obtain the pressure
dew point -40℃.
(Pressure 7.0 bar, Pressure Dew Point -18℃ can be converted to atomic Dew Point -40℃ by following the
line 1) What is the pressure dew point at the pressure 7.0 bar at -18℃?
Locate the atmospheric pressure dew point -18℃ at the bottom of the chart and draw a vertical line and follow
it horizontally at the point where it intersects the pressure line at 7.0 bar to obtain the atmospheric pressure
dew point of 10℃.
(Atmospheric Pressure, Dew Point -18℃ can be converted to 7.0bar Pressure Dew Point 10℃ by following the line ②)

압력노점
Pressure DewDew
Pressure Point (℃)
Point(℃)
Pressure 82
압력
Pressure
(bar) 77
(bar)
71
66
60
54
49
43
38
32
27
21
16
2 2 10
4
-1
-7
-12

210
1 1 -18
-23
140
70
-29

32 -35
28 -40
14 -46
7.0 -51
3.0 -57
1.4
-63
0.35
-68
-73
1 2
-70 -63 -57 -51 -46 -40 -35 -29 -23 -18 -12 -7 -1 4

Atmospheric
대기압노점 Pressure Dew Point
Atmospheric Pressure Dew Point
22 | Global Standard Air / Gas
Amount of Saturated Water Vapor Table

RH 100% : g/m3

60℃ 129.7200 28℃ 27.2210 -4℃ 3.5199 -37℃ 0.1642

Ref. Air Dryers


59℃ 124.2100 27℃ 25.7600 -5℃ 3.2444 -38℃ 0.1476
58℃ 118.8900 26℃ 24.3660 -6℃ 2.9888 -39℃ 0.1326
57℃ 113.7700 25℃ 23.0380 -7℃ 2.7516 -40℃ 0.1189
56℃ 108.8300 24℃ 21.7730 -8℃ 2.5314 -41℃ 0.1066
55℃ 104.0800 23℃ 20.5680 -9℃ 2.3267 -42℃ 0.0954
54℃ 99.4920 22℃ 19.4210 -10℃ 2.1379 -43℃ 0.0854

Desiccant Air Dryers


53℃ 95.0840 21℃ 18.3290 -11℃ 1.9632 -44℃ 0.0763
52℃ 90.8360 20℃ 17.2910 -12℃ 1.8014 -45℃ 0.0682
51℃ 86.7550 19℃ 15.5620 -13℃ 1.6517 -46℃ 0.0608
50℃ 82.8230 18℃ 15.3660 -14℃ 1.5133 -47℃ 0.0542
49℃ 79.0420 17℃ 14.4750 -15℃ 1.3856 -48℃ 0.0482
48℃ 75.4140 16℃ 13.6290 -16℃ 1.2679 -49℃ 0.0429
47℃ 71.9250 15℃ 12.8270 -17℃ 1.1596 -50℃ 0.0381
46℃ 68.5700 14℃ 12.0650 -18℃ 1.0595 -51℃ 0.0338

Accessories
45℃ 65.3500 13℃ 11.3430 -19℃ 0.9673 -52℃ 0.0299

44℃ 62.2590 12℃ 10.6590 -20℃ 0.8821 -53℃ 0.0265

43℃ 59.2930 11℃ 10.0110 -21℃ 0.8044 -54℃ 0.0234


42℃ 56.4480 10℃ 9.3977 -22℃ 0.7328 -55℃ 0.0207
41℃ 53.7180 9℃ 8.8171 -23℃ 0.6670 -56℃ 0.0183
40℃ 51.1020 8℃ 8.2686 -24℃ 0.6067 -57℃ 0.0161
39℃ 48.5950 7℃ 7.7494 -25℃ 0.5514 -58℃ 0.0142
38℃ 46.1930 6℃ 7.2589 -26℃ 0.5008 -59℃ 0.0125 Gas Equipments
37℃ 43.8930 5℃ 6.7958 -27℃ 0.4544 -60℃ 0.0109
36℃ 41.6910 4℃ 6.3588 -28℃ 0.4120 -62℃ 0.00840
35℃ 39.5830 3℃ 5.9466 -29℃ 0.3733 -63℃ 0.00734
34℃ 37.5680 2℃ 5.5579 -30℃ 0.3379 -65℃ 0.00560
33℃ 35.6410 1.7℃ 5.4458 -31℃ 0.3056 -68℃ 0.00369
Useful Information

32℃ 33.7990 1℃ 5.1917 -32℃ 0.2762 -70℃ 0.00277


31℃ 32.0390 0℃ 4.8467 -33℃ 0.2493 -73℃ 0.00179
30℃ 30.3580 -1℃ 4.4777 -34℃ 0.2249 -75℃ 0.00133
29℃ 28.7560 -2℃ 4.1352 -35℃ 0.2027 -78℃ 0.000836
28℃ 27.2210 -3℃ 3.8167 -36℃ 0.1826 -80℃ 0.000610

Global Standard Air / Gas | 23


Air & Gas Treatment System Example
When air in the atmosphere is inhaled and pressurized by air compressor, the system life of production line and
various pneumatic devices and the deterioration of function are critical. Therefore, pollution control shall be preceded
by economical reliability, maintenance, and so on.

Compressed air is saturated with water. Since the compressed air is heated during the compression, aftercooler
is then used to remove the heat of compression. During this stage, when ambient air is compressed, a significant
quantity of condensate is made.
This condenstate, if not removed, will cause erosion, damage to pneumatic equipment and instruments. Filtering
and drying processes remove particles, moisture, microbes, and chemicals from compressed air. Clean, dry air
protects the air system reduces maintenance costs and incrases finished product yields.

24 | Global Standard Air / Gas


COMPRESSED AIR QUALITY CLASS ISO8573.1:2010

Maximum number of particles per m3 Vapour Pressure


ISO8573-1:2010 Total Oil
Dew Point(℃)
CLASS 0.1 ~ 0.5 micron 0.5 ~ 1.0 micron 1.0 ~ 5.0 micron mg/m3
@ 7 barg
1 20,000 400 10 -70 0.01
2 400,000 6,000 100 -40 0.10

Ref. Air Dryers


3 - 90,000 1,000 -20 1.00
4 - - 10,000 +3 5.00
5 - - 100,000 +7 -
6 - - +10 -

Air Quality Class Description


■ ISO8573.1:2010 Class(Particle, Water, Oil)
Example
■ SO8573.1:2010 Class 1.2.1
- Particle 1 : 0.1 ~ 0.5 micron/m3(Particle Max 100ea) 0.5 ~ 1.0 micron/m3
Particle Max 1ea 1.0 ~ 5.0 micron/m3(Particle 0)
1.0 ~ 5.0 micron/m3(Particle 0))
- Water 2 : -40℃(Pressure Dew Point -40℃)
- Oil : 0.01mg/m3(Total Oil 0.01mg/m3 )

Desiccant Air Dryers


Dew Point 4℃ | Total Oil 1 ppm | Particle 1 μm

PP

Service Air Mine Steel Power Glass & Plasticr


Air Tools Air Tools Control System Gas Turbine Control System
Air for Breath Casting Facilities Emergency Conveyor System
Conveyor System Protect Facilities Production Process
Gas Booster

Accessories
Dew Point 4℃ | Total Oil 0.1 ppm | Particle 1 μm

Paper&Textile Machinery Gas Painting Environment

Control System Auto Machine Liquefaction Painting Waste Water


Conveyor System Service Air Conservation Paint Removal Disposal Plant
Service Air Service Air Incinerator
Dust Collector

Dew Point -40℃ | Total Oil 0.01 ppm | Particle1 μm

Gas Equipments
Air Craft Marine&Automobile Petroche-mical Automation Chemistry PrecisePainting
Enginestarting Control System Refinery Control System Laboratory Powder Painting
Service Air Enginestarting Production Starting System Control System Coating
Service Airr Service Air Storage
Conveyor System Control System

Dew Point -70℃ | Total Oil 0.003 ppm | Particle 1 μm


Useful Information

Medical& Liquefaction PowderTransfer&


Nuclear Power Pharma-ceutical Seperation Liquid Mixture Electronics Food Environment
Nuclear Reactor Control System Liquefaction Control System Control System Powder Painting O2 Generator
Reactor Cooling Enginestarting Control System Starting Coating System Coating
Control System Service Airr Production Heat Control Storage
Process System Control System

Global Standard Air / Gas | 25


Air/Gas Dryer
GSA leads the compressed air processing equipment industry. The following
items are designed and manufactured by us: Refrigerated dryers (cycling,
Global Standard Air

noncycling, high temperature, filter-in), adsorption dryers (non-heating,


heating, compression heat, zero purge gas type), membrane dryers, natural
gas dryers, and breathing dryers are customized and manufactured according
to customers' orders.

Gas Generator/Purifier
GSA leads the gas generators and refineries industry. The following items
are designed and manufactured by us: PSA-type nitrogen generators,
oxygen generators, hydrogen purifiers, argon/carbon monoxide/carbon/
methane recovery purification plants, and other various gas separation and
purification plants are custom-made.

Air/Gas chiller
GSA designs and manufactures special purpose air/gas chiller. GSA's air-
Global Standard Air

cooled and water-cooled chiller boasts excellent efficiency and convenient


control by employing the latest heat exchanger, solder evaporator, and
microchannel type condenser. It's also easy to install, so you can experience
significant savings over traditional chiller.

www.gsadryer.com