UT level-III Questions fromcomputer based examination held on 14-Aug-2017
1. A plate scanned by a flat surface probe. How will pass through the probe?
a. convergence plate if convex
b. divergence plate if convex
c. sound travel in a straight to plate
2. From figure 8 which is back wall echo ?
a. CFI
3. From figure 8 which is echo from Defect ?
a. BEH
4. For ingot at normal temperature which is best method to use?
a. EMAT
b. Squitter
c. Focused angle beam
d. Straight beam
5. To cover the full weld area of one inch thickness , which one scan can used ?
a. Half leg length
b. Full leg length
c. one half leg length
d. two leg length
e.
6. to cover weld area how many skip distance is needed?
a. T tanØ
b. 2 T tanØ
c. 3 T tanØ
d. 4 T tanØ
7. for 2 tan Ø, how many leg area shall be covered ?
a. one leg length
b. Two leg length
c. one and half leg length
Page 1 of 7
UT level-III Questions fromcomputer based examination held on 14-Aug-2017
d. two leg leg length
8. A device using liquid stream to couple UT wave to test part?
a. Bubbler
9. Which is difficult to scanned by UT ?
a. A thin smooth surface
b. a thicK smooth surface
c. A thick rough surface with rough contour
10. When checking ASME pressure vessel, you have found two echo at ¾ and ¼ .What have to
do?
a. Check the previous history , if defect is noted, leave as it is
b. Plate always have lamination so don’t report
c. inform to owner
d. conform with by C scan and if defect found report to owner
11. Which calibration block is used for angle beam inspection and Straight beam inspection ?
a. Reference block with notch
b. Reference block with FBH
c. Reference block with SDH
12. Refer Procedure
No:6 use for
a. Tee Joint
b. 2 ½ inch butt joint
c. 4 ¾ Corner Joint
d. As welded condition
13. The intial pulse on screen called ?
a. Initial echo
b. Main bang
Page 2 of 7
UT level-III Questions fromcomputer based examination held on 14-Aug-2017
14. Lack of found and 2 degree rotation is given . what will be echo pattern
a. Sudden drop in Echo amplitude
15. Tungsten Insclusion hase been by UT found. How echo Pattern will be ?
a. Same as Sand Inclusion
b. Crack
c. Lack of fusion
d. Lack of penetration
16. FROM Fig 7 – A is
a. Longitudinal wave
17. From fig 7 B is
a. Shear wave
18. Which beam can used for 10.5 OD and 1.5 thick circular job. Refer fig 8 in reference book
a. 36.5 degree
b. 46 degree
c. 70 degree
d. 60 degree
Page 3 of 7
UT level-III Questions fromcomputer based examination held on 14-Aug-2017
19. For checking angle beam calibration which is first to check ?
a. Index point
b. Sensitivity
c. Resolution
d. Angle of Probe
20. When you inspecting Root lack of penetration in T joint with having “V” groove
Which is the best method ?
a. Scan by Angle beam
b. Scan by straight beam from from flange
c. Scan from angle beam and scan by straight from flange
21. Which one is shortest wave ?
a. Shear wave
b. Surface wave
c. Rayliegh wave
d. longitudinal wave
22. Which wave travel parallel ?
Longitudinal wave
23. Which wave travel to normal?
a. Shear wave
24. A echo with low amplitude travel along scanning it may be ?
a. Micro figure
b. Grain difference
c. Fine Crack
Page 4 of 7
UT level-III Questions fromcomputer based examination held on 14-Aug-2017
25. 5-0300 distance amplitude block ?
a. 5 inch length 3/64 inch hole
b. 5 inch metal travel distance with 3/64 inch hole
c. 5 inch length with ¾ hole in different areas
26. Which method best of scanning Curved Surface?
a. Straight beam
b. Angle beam with focused probe
c. Bubbler
d. Straight beam with focused probe
27. Requirement of high speed scanning?
a. Scanning should find echo on different speed
b. ..
28. Calibration blocks having?
a. Three or more hole on SDH in different depth and location
b. Three hole or more holes in same location
c. Notch having different location
d. Many notches on same location
29. Difficulties in scanning of Ingots?
a. Coarse Gain
b. ..
30. Also about Ingot and coarse Gain
31. shear wave testing of weld inspection a flaw indication is detected by a peak at reference
level of sensitivity and additional 8db is removed to bring the signal to reference level. What
will be the size of the reference level ?
a. 2.5 db down
b. 2.5 db up
c. 2.5 ……..
32. Refracted angle of Aluminium in Water interface?
a. 8 degree
b. 23 degree
c. 27 degree ??
d. 60 degree Transmit receiver
33. TR probe best used for ?
a. Thickness checking
b. Surface Scanning
34. TR probe with Delay line best used for ?
a. Thickness checking
Page 5 of 7
UT level-III Questions fromcomputer based examination held on 14-Aug-2017
35. The minimum defect size can be find using Ceramic Transducer ?
a. 3000 µm
b. 3µm
c. 300µm ?? Ultrasonic Pulse
Velocity (UPV)
d. 3 mm
36. For concrete UT scanning with is best UT method is used?
a. ???
37. A 1000 mm plate scan by immersion testing by 10 probe .To cover full area what speed
speed is required ?
a. 10 mm/sec
b. 100 mm /sec
c. 1000 mm/ sec
38. For 4 inch Aluminium plate is scanned by immersion testing , how water distance is
required ?
a. 1 inch
b. 2.5 inch
c. ..
39. How much thickness metal can be test by surface wave ?
a. One wave length
b. one half wave length
c. one tenth wave length
d. half wave length
40. Surface wave length ?
a. one wave length
b. 1/10 wave length
Page 6 of 7
UT level-III Questions fromcomputer based examination held on 14-Aug-2017
41. figure 4 which having better relation with each other?
a. 2 ,4
b. 3,4
c. 1,5
d. 1,3
42. When calibrating in UT same material may not available, for calibrating a Titanium forging
calibration block is not available , What can do ?
a. Use the same material
b. Use different material with same Acoustic property
c. same material with same roughness
d. impossible to check by UT without proper calibration block
43. For offshore inspection which Standard is use ?
a. ASME
b. AWS
c. API
d. ANSI
44. In immersion testing method a Plastic and Rubber materials are used ?
a. ??
b. ??
Page 7 of 7