for
Diagnostic Ultrasound System
SPH-ARIETTA850DI-V50-U01
Printed in Japan, 2022-11
1
Basic Specifications ・ B(eFLOW) and Dual
Scanning Method ・ B(Color Flow) and D simultaneous real-time display
・ Electronic Convex (Triplex mode)
・ Electronic Linear ・ B(Power Doppler) and D simultaneous real-time display
・ Electronic Phased Array Sector (Triplex mode)
・ Electronic Radial ・ B(eFLOW) and D simultaneous real-time display(Triplex
mode)
Operating Modes ・ B and B(Color Flow) simultaneous real-time display
・ B-mode (Dual Flow)
・ BiPlane-mode ・ B and B(Power Doppler) simultaneous real-time display
・ M-mode (Dual CF)
・ D: Spectral Doppler mode (PW, CW, HPRF-PW) ・ B and B(eFLOW) simultaneous real-time display(Dual
・ Dual Gate Doppler mode Flow)
・ Color Flow mode ・ Dynamic Slow-motion Display(Real-time image/Slow-
・ Power Doppler mode (Directional Power Doppler) motion image, side by side display)
・ eFLOW mode (Directional eFLOW) ・ Real-time Biplane(Display real time image in 2 cross-
・ Cardiac 3D mode* sections in biplane probe.)
(3D Zoom, Active 3D, Wide Angle 3D) ・ Panoramic View
* Option: SOP-ARIETTA850-129, EU-9207, PEU-LISENDO880 ・ TDI(Tissue Doppler Imaging)
・ Intermittent trigger mode*2
Image Display Modes*1 ・ Monitor mode(Monitor image/CHI mode image, side by
・ B: gray-scale imaging side)*2
・ Dual B ・ RT-3D(4D) mode*3
・ Quad B ・ Detective Flow Imaging(DFI)*4
・M ・ Request function: In multi-mode display, it is possible to
・ B and M select one mode for full screen display.
・D ・ Real-time Tissue Elastography*5
・ B and D ・ 3D Zoom mode(Color)*6
・ B(Color Flow) ・ Active 3D mode(Color)*6
・ B(Power Doppler) ・ Wide Angle 3D mode(Color)*6
・ B(eFLOW) *1 Probe dependent.
・ Dual B(Color Flow) *2 Option: SOP-ARIETTA850-44
・ Quad B(Color Flow) *3 Option: EU-9184, SOP-ARIETTA850-4
・ Dual B(Power Doppler) *4 Option: SOP-ARIETTA850-105
・ Quad B(Power Doppler) *5 Option: SOP-ARIETTA850-43
・ Dual B(eFLOW) *6 Option: SOP-ARIETTA850-129, EU-9207, PEU-LISENDO880
・ Quad B(eFLOW)
・ M(Color Flow) Beam former
・ M(Power Doppler) ・ Transmission
・ M(eFLOW) CPWG(Compound Pulse Wave Generator)
・ B(Color Flow) and M(Color Flow) Programmable waveform transmission
・ B(Power Doppler) and M(Power Doppler) ・ Reception
・ B(eFLOW) and M(eFLOW) Multi processing high-speed digital beam former
・ B(Color Flow) and D 12-bit A/D converter(4096 gray levels)
・ B(Color Flow) and Dual A/D Sampling Frequency: 40 [MHz]
・ B(Power Doppler) and D Parallel processing: Up to 20 directions
・ B(Power Doppler) and Dual ・ Transmission/Reception method of Harmonics:
・ B(eFLOW) and D FmT: Filter-method Tissue Harmonic Imaging
2
ARIETTA850DI-V50
THI mode image without reducing the frame rate. Minimum display of 5mm
WbT: Wide-band Tissue Harmonic Imaging ・ Frequency selection:
THI mode image with higher resolution than FmT. Fundamental:
HdT: High Definition Tissue Harmonic Max. 5 frequencies
Imaging(HdTHI) Tissue harmonic:
THI mode image with higher resolution than WbT. Max. 5 frequencies
Reception frequency: 3.2-22.0 MHz* ・ Depth range selections:
*: 22.0 MHz can be achieved under below conditions. 0.75/1.0/1.5/2.0/2.5/3.0/3.5/4.0/4.5/5.0, 1 cm
Probe: SML44 intervals from 5.0 to 24 cm, and 2 cm intervals from
Frequency: High 24 cm to 40 cm(probe dependent)
Frequency Information: Receive ・ Longitudinal and lateral inversion
・ Tissue Adaptive Technology: ・ Rotation by 90 degrees(probe dependent)
Sound speed adjustment: 26 steps ・ Gain
Automated sound speed adjustment 0 to 80 dB, 1 dB step, adjustable in real-time and
・ Focusing frozen.
Transmission Echo enhancement: 8 steps(Including OFF)
Multi-stage transmission focus of up to 4 stages Texture: 2 steps(Smooth/Sharp), not available in M-
out of 16 stages (probe dependent) mode.
Reception: PixelFocus, eFocusing Smooth/Enhance:
-8 to -1: Smoothing level
System Dynamic Range 0: OFF
320 dB 1 to 8: Edge enhancement level
Persistence
System Processing Channels 8 steps(Including OFF), 2 types(Manual/Auto)
7,072,000 Channels Time Gain Control(TGC): Gain versus depth curve
control
Frame rate 8 slide controls, TGC curve memory function
Max. 882 frames/sec* TGC Enhancement: ON/OFF possible, working with CF
* It is a measured value with the setting assuming the Lateral Gain Control(LGC): Gain versus angle curve
maximum value. This value may be exceeded depending on the control.
conditions. 8 sectors(Sector probes only)
Dynamic range
Volume rate(Mechanical 3D scanning) 40 to 90 dB, adjustable in real-time and frozen.
Max. Up to 41 volumes/sec* Gray map: 10 types, adjustable in real-time and frozen.
* Depends on probes and various settings Auto Gain Control(AGC): 8 steps(Including OFF)
Gamma Curve
Imaging 4 types(Linear, Window, Parabolic, S-curve), control
B-mode points(Rejection, Center, Saturation), changeable in
・ Display Gray Scale: 256 levels real-time and frozen.
・ Scanning area: Compound
25 to 100%, Continuously variable Possible by selected linear and convex sector probes.
・ Line Density: Up to 8 steps Trapezoidal Scanning
・ HI Frame Rate Possible by selected linear probes
Improve frame rate by Multi Parallel Processing Beam Steer
・ Zoom: Possible by selected linear probes
HI zoom(real-time image): DeepInsight
Minimum display of 5mm Clarifies the borders of structures and reduces speckle
PAN zoom(real-time and frozen image): noise and artifacts.
3
ARIETTA850DI-V50
eFocusing PLUS brightness and high brightness of grayscale.
Synthesizes multiple types of ultrasound beams to OFF+3 steps(Low, Mid, High)
reduce artifacts such as side lobes, multiple echoes, and ・ Free Angular M(FAM): Displays an M mode image on
speckle noise and to improve the spatial resolution and any line of the B mode image.
sensitivity of the image.
HI REZ: Image filter that maintains the edges of Spectral Doppler Mode
structures while reducing speckle noise. ・ Display: Power spectrum
8steps, ON/OFF possible ・ Real-time Doppler Auto Trace
HI REZ PLUS: ON/OFF possible ・ Doppler methods:
Border Clear Filter(BCF): Image filter that enhance the PW(Pulsed Wave) Doppler
edges of structures. HPRF(High Pulse Repetition Frequency) PW Doppler
ON/OFF possible, only available when HI REZ is ON Dual Gate Doppler
・ Acoustic Noise Reduction(ANR): It reduces artifacts. CW(Continuous Wave) Doppler*
OFF+9 steps, 2 types(A-B) TD(Tissue Doppler)-PW
・ Near-field Noise Reduction(NNR): It reduces artifacts ・ Reference frequencies (probe dependent):
and noises in the heart chamber or blood vessels. Maximum 3 frequencies
OFF+3 steps(Low, Mid, High), 5 types(A-E) PW: 1.5, 1.9, 2.0, 2.1, 2.5, 3.0, 3.3,
Carving Imaging: OFF+9 types(combination of NNR 3.5, 3.8, 4.0, 4.4, 5.2, 6.0, 6.3 MHz
type(C, D, E) and levels(Low, Mid, High)) CW: 1.7, 1.8, 2.0, 2.1, 2.5, 3.0, 3.3, 3.8, 5.0 MHz
・ Low Echo Reduction: Suppresses the hypoechoic areas. ・ Pulse repetition frequency
0 to 70%, 2% step, adjustable in real-time and frozen PW: 0.05 to 40 kHz
・ Grayscale Enhancement: Sets the balance between low ・ Analysis rate
brightness and high brightness of grayscale. CW: 1.1 to 40 kHz
OFF+3 steps(Low, Mid, High) ・ Max. velocity range:
・ Auto-optimizer: Gain, TGC, LGC, sound velocity PW/HPRF: ±1.26 cm/sec to ±802.08 cm/sec
・ Needle Emphasis: Improves the visibility of the puncture CW: ±25.07 cm/sec to ±1600 cm/sec
needle echo. ・ Base line shift: Adjustable in real-time and frozen.
・ Wide Scanning: Display image with a wide field of view. ・ Steerable CW: Possible with selected probes.
・ Panoramic View: Display a panoramic image by moving ・ Beam Steer
the probe in a wide range. -30 to 30 degrees(probe dependent), 5 degrees step,
possible with linear probes.
M-mode ・ Spectrum inversion
・ Sweep method: Moving bar ・ Angle correction
・ Sweep speed 0 to 80 degrees, adjustable in real-time and frozen.
7 steps(40.0, 50.0, 66.7, 100, 133.3, 200, 300 Auto angle correction
mm/sec) ・ Sample Volume
・ Gain Size: 0.5 to 20 mm(0.5 mm,1.0 mm step)
B Gain±30dB, working with B Gain, adjustable in real- Display depth of the sample volume
time and frozen. ・ Wall filter: 12 steps, 1/16 of PRF is Max.
・ Dynamic Range ・ Gain
40 to 90 dB, 1 dB step, adjustable in real-time and 0 to 60 dB, ON/OFF possible, adjustable in real-time
frozen. and frozen.
・ Auto Gain Control(AGC): 8 steps(Including OFF) ・ Low Echo Reduction: Suppresses the hypoechoic areas.
・ Acoustic Noise Reduction(ANR): It reduces artifacts. 0 to 30%, 2% step
Working with B mode. ・ Grayscale Enhancement: Sets the balance between low
・ Low Echo Reduction: Suppresses the hypoechoic areas. brightness and high brightness of grayscale.
0 to 70%, 2% step, adjustable in real-time and frozen. OFF+3 levels(Low, Mid, High)
・ Grayscale Enhancement: Sets the balance between low ・ Echo Enh.: OFF+2 levels(Low,High)
4
ARIETTA850DI-V50
・ Dop. Gamma: Changes the Doppler waveform contrast, Persistence Level: 8 steps(Including OFF)
and the level of gamma adjustment. Wall Filter: 6 steps
8 levels, adjustable in real-time and frozen. Wall Motion Reduction(WMR)
・ Auto Optimizer: Automatically adjusts image. OFF + 3 steps(Low, Middle, High), 2 methods
Gain, PRF, baseline, Angle Correction, position of Wall Motion Reduction(WMR) PLUS: Remove body
sample volume movement due to clutter signals.
・ Audio output: 2 channels OFF + 3 steps(Low, Middle, High)
* Option: EU-9184 Packet Size: 3 levels(Large, Middle, Small)
Baseline Shift: Up to double velocity(±64 steps)
Color Doppler Mode Color Map: 15 kinds
・ Flow area: 25 to 100%, 5% step TGC Enhancement
・ Beam Steer ON/OFF possible, working with B mode
-30 to 30 degrees(probe dependent), 5 degrees step, Display superimposed color image
possible with linear probes Accumu. Imaging: ON/OFF possible, in real-time.
・ Line Density Capture Imaging: ON/OFF possible, in frozen.
8 levels, adjustable independently with B mode. Power Doppler(PD) mode
・ Gain: 128 levels Displays color on the image according to the intensity of
・ Texture: 2 levels(Smooth/Sharp) the color Doppler signal. It is sensitive to slow blood
・ Glossy Level: OFF+4 levels flows.
・ HI Frame Rate: Improve frame rate by Multi Parallel Display patterns: PD, Directional PD
Processing. Gradation: 256 levels
・ Auto Optimizer: Automatically adjusts image. Color Map: 15 kinds
Gain, position of ROI Non-display of B/W image: Possible in ROI
iVascular Smoothing: 5 steps, adjustable in real-time and frozen.
Automatically identifies the long-axis blood vessels Wall Filter: 6 steps
in an image, and sets the position of the flow area, Wall Motion Reduction(WMR)
the position and size of the sample volume, the OFF + 3 steps(Low, Middle, High), 2 methods
blood flow direction, and the angle of the ultrasound Wall Motion Reduction(WMR) PLUS: Remove body
beam(angle correction). movement due to clutter signals.
Color Flow(CF) mode OFF + 3 steps(Low, Middle, High)
Displays the orientation and velocity in color on the Carving Imaging: Clarifies the boundaries of blood flows
tomographic image, based on the Doppler signal and changes the level for reducing speckle noise.
obtained from the blood flow. 5 steps
Display patterns: High Resolution Power Doppler(eFLOW) mode
Velocity(derived from mean Doppler frequency shift), Displays in the Power Doppler mode in high-resolution.
Velocity + variance, Variance, Velocity + intensity, Display patterns: eFLOW, Directional eFLOW
Velocity + variance + intensity Pulse repetition frequency: 0.03 to 19.8 kHz
Max. velocity range Gradation: 256 levels(±127 levels for directional)
±0.63cm/sec to ±458.33cm/sec Color Map: 15 kinds
Reference frequency(probe dependent) Smoothing: 5 steps, adjustable in real-time and frozen.
1.9, 2.0, 2.1, 2.5, 3.2, 3.3, 3.5, 4.0, 4.4, 5.2, 6.0, 6.3 Wall Filter: 6 steps
MHz Wall Motion Reduction(WMR)
Pulse repetition frequency: 0.03 to 19.8 kHz OFF + 3 steps(Low, Middle, High), 2 methods
Gradation: Wall Motion Reduction(WMR) PLUS: Remove body
Velocity: ±127 levels(red and blue) movement due to clutter signals.
Variance: 64 levels(green) OFF + 3 steps(Low, Middle, High)
Invert Color Map Carving Imaging: Clarifies the boundaries of blood flows
Smoothing: 5 steps, adjustable in real-time and frozen. and changes the level for reducing speckle noise.
5
ARIETTA850DI-V50
5 steps and the points at 1cm on the right and left of the max
IMT, can be automatically detected and averaged.
Cine Memory
・ Cine search and loop display (in B mode): Stress Echo analysis*
ECG time phase display is possible It is an examination in which the heart is subjected to
・ Capacity stress through exercise or drugs, for example, in order to
B mode: Max. 63,500 frames. check for abnormalities of myocardium.
M/D mode: Max. Approx. 900 seconds. Stress Echo involves acquiring images before and after
the application of stress, displaying the images alongside
Physiological Signal Display each other, synchronizing the heartbeats and looping the
・ Displayed information: playback. This permits periodic evaluation of images.
ECG, PCG*1, Pulse*2, Breathing waveform Stress echo report can be created using the scoring
・ ECG synchronized display: Available for one phase function.
・ Detect regular pulse from arrhythmia(RRp/RRpp) Image display modes in which image acquisition is
・ Automated jumping to most optimized R-R Phase possible: B, Each Flow modes
・ Reducing Filter for Tachy or Bradycardia Methods for acquiring images
・ Display value for each R-R interval time Temp acquisition: Acquire a preset heart rate. This
・ Display position: method allows you to acquire color images.
Continuously variable(both in B and M modes) Conti acquisition: Continuous acquisition. This
・ Bar graph display for breathing waveform method cannot acquire color images.
・ 3 type electrocardiogram(I, II, III) Protocol: Skip Stage/Skip View is possible during exam.
・ Automated detection end diastole and end systole Exercise stress protocols:
phase. Exercise Stress Echo
・ Automated split as end diastole(left) and end Treadmill Exercise
systole(right) Bicycle Exercise
*1 Option: MA-300 Pharmacological stress protocols:
*2 Option: TY-307A DSE
High-Dose DSE
Tissue Doppler Imaging(TDI) Low-Dose DSE
・ Switching Color Doppler and Tissue Doppler during Arbutamine
exam is possible. Dipyridamole
User's protocol:
Dual Gate Doppler The user can make a protocol within 8 views X 12
This is a function which displays Doppler Spectrums of stages in 1 exam.
two different sample points simultaneously. Full disclosure: Max. 2,481 seconds(Depends on
Supported combinations are PW/PW, TDI/TDI, and probes and various settings)
PW/TDI*. 2,481 seconds can be achieved under below
Automated sample gate setting for each gate. conditions.
*: It is possible to measure E/e’ immediately(approx. 5 seconds) Probe: S121(Adult Heart)
by recognition of imaging view and placement of sample volumes Protocol: Conti. only(1Stage/1View)
automatically in addition to detect stable heart beats with R-R Frequency: 30Hz
Navigation. Scan Area: Minimum
Automated Intima-Media Thickness(IMT) Line Density: Minimum
Measurement Automatic labeling: Possible(Auto ON/OFF is also
It is possible to automatically extract max, min, average possible)
and SD of IMT by simply setting ROI(region of interest) Comparing images
on a long-axis view of the vessel. Shuffle Stage: Displays the same view of each stage
The thicknesses at 3 points, i.e., the point at max IMT, for comparison.
6
ARIETTA850DI-V50
Shuffle View: Displays the different views of the
same stage for comparison.
Compare: Lines up the same view of any stage
left/right for comparison.
Loop speed: Adjustable
Scoring: Possible
Report
Chart display: Display scoring results in a list.
Schema(Shuffle View) display: Display scoring
results by a schema(list of the same Stage).
* Option: PEU-LISENDO880
Automated NT Measurement
It is possible to automatically extract the nuchal
translucency(NT) thickness by simply setting ROI(region
of interest). In addition, thicknesses at max NT, Mean NT
can be automatically calculated.
Protocol Assistant
This function ensures that all measurements and image
saving are performed without fail by carrying out
examinations with the protocol that has been registered
in advance.
・ Protocol registration: 128 kinds can be registered.
・ Suspend protocol function
・ Create and edit protocol on the system
・ Register and edit reference image
・ Import/Export protocol
Manual
It is applicable to browse instruction manual on this
system.
・ On-board operation manual
7
ARIETTA850DI-V50
Data Management Measurement data
Image data It is possible to store measurement data in the main
Format unit hard disk
Multiple-frame(moving) image
DICOM(Raw, MJPEG) Patient data
PC Format(WMV, AVI, MP4) Displayed information*1
Single-frame(still) image Patient information*2
DICOM(Non-compressed, RLE, RGB(Plane/Pixel), ID(up to 64 characters), Name(up to 64
JPEG) characters, including middle name), Birthdate, Sex,
PC Format(Tiff, Bmp, JPEG) Age, Height, Weight, Occupation
Image acquisition mode Study information
Real-time multi-frame image acquisition Procedure ID, Accession, Study ID, Study
Raw, Image, RAW and Image at the same time Description, Referring physician, Reporting Phys,
Post ECG: Max. 10 cardiac cycles(R-R) Sonographer
Pre ECG: Max. 10 cardiac cycles(R-R) *1: Conforms to DICOM 3.0 standard
Post Time: Max. 90 seconds *2: Encryption function is available.
Pre Time: Max. 16 seconds
Manual: Data storage
Raw data: Max. 150 seconds Main unit hard disk*
Image data: Max. 180 seconds Capacity: Approx. 1TB
Cine loop high-speed data transfer(Raw, Image) USB memory*
It is possible to selectively store data of arbitrary USB HDD*
section in the Cine Memory. CD-R
Simultaneous output to multiple media DVD-RAM
It is possible to output still image data to multiple DVD-R
of storage media include network and printers at Network interface(DICOM format)
the touch of a button. 10 BASE/T or 100 BASE/TX, automatically switched
Image data management tool *: Encryption function is available.
Image viewer
Compatible with DICOM and PC-format images DICOM network communication
Simultaneous display of stored and real-time ・ Conformity to DICOM service class:
images is possible(Compare mode) Ultrasound image storage SCU
Thumbnail display of stored images(1-36 images) Ultrasound multi-image storage SCU
Check mark is put on a transferred image Storage media FSC/FSR
Image zoom, rotation, inversion Print management SCU
Protect stored images Modality worklist management SCU
1:1 replay(main unit HDD or DICOM storage Modality performed procedure step(MPPS) SCU
data) (For details, please refer to the DICOM Conformance
DVD-RAM Statement issued by FUJIFILM Healthcare
CD-R Corporation.)
USB memory ・ Storage
USB HDD Possible to store patient information directly to DICOM
Re-storing to media, transfer file server.
Adjustment is possible on the reconstructed Raw- ・ Print
data image (Gain, Dynamic Range, Gamma Possible to printout images with DICOM compatible
Curve, and Color Map in CF mode) printer directly.
・ Work list management
Retrieval of patient and reservation information from
8
ARIETTA850DI-V50
hospital information system(HIS)
NOTE: The HIS needs to be compatible with DICOM standard
supplement 10. The HIS network and the DICOM network
need to be linked.
・ Router setting
・ Compatible with SR(Structured Report) for OB,
cardiology, vascular and abdominal measurements*
・ Query/Retrieve
・ Compatible with ED(Evidence Documents)
・ Profile
・ Integrated Healthcare Enterprise(IHE)
SWF(Scheduled Workflow)
PDI(Portable Data for Imaging)
ED(Evidence Documents in Radiology/Cardiology
domain)
Echocardiography Workflow
CT(Consistent Time)
* Option: SOP-ARIETTA850-21
Security measures
User authentication function is available.
3 Types of user authority can be set.
It is possible to set whether password is necessary or
not at the start of operation.
Audit logs
Accesses related to user management and patient
data are recorded as audit log data.
Handling of these logs is limited to users with Level 1
access.
Teaching file
Possible to create teaching file.
9
ARIETTA850DI-V50
Measurements and Analysis Common bile duct measurement: CBD
Basic measurements Liver measurement: Liver
B mode Pancreas measurement: Pancreas
Distance measurement: Distance, Dist-trace Pancreatic duct measurement: P-Duct
Area and Circumference measurement: Area/Circum Renal measurement: Renal Volume
Volume measurement: Volume1, Volume2 Spleen measurement: Spleen
Angle measurement: Angle Space-occupying lesion measurement: SOL
Histogram measurement: Histogram Blood vessel diameter measurement
Measurement of Congenital Dislocation of the Hip Joint: Aorta Diam, PV Diam
Hip J Angle Stenosis percentage measurement
General purpose index measurement: B.Index %STENO-Diam, %STENO-Area
M mode D mode
Distance measurement: M.Length Artery measurement
Time measurement: Time A-Ao, CA, CHA, SA, SMA, IMA, CIA, HA, Prandial SMA
Heart rate measurement: Heart Rate Renal artery measurement*
Velocity measurement: M.VEL. Renal-A, RA hilum, Seg.A Upp, Seg.A Mid, Seg.A Low
General purpose index measurement: M.Index Portal vein measurement: Main PV, Rt.PV, Lt.PV
Shunt blood vessel measurement
D mode Pre Shunt PV, Prox Shunt, Mid Shunt, Distal Shunt
Time measurement: Time
Heart rate measurement: Heart Rate B/D mode
Blood flow velocity measurement: D.VEL1, D.VEL2 Blood flow volume measurement
Acceleration (deceleration) measurement: ACCEL FV(Artery) Abdom, FV(Vein) Abdom
Resistance index measurement: RI *: Auto trace is possible.
Pressure half-time measurement: P1/2T
Dop.Caliper measurement: D.Caliper1, D.Caliper2 Cardiology measurements
Measurement of mean velocity and mean pressure B mode
gradient*1: Mean VEL. L Cardiology measurements
Pulsatility index measurement*1: PI M.Simpson*1, GLS(3P)*2, Area-Length*1, Pombo*2,
Stenosis flow measurement*1: Steno Flow Teichholz*2, Gibson*2, Bullet, Simpson, BP-Ellipse,
Regurgitant flow measurement*1: Regurg Flow EyeballEF*3
Dop.Trace measurement*1: D.Trace1, D.Trace2 Valve area measurement: AVA, MVA
General purpose index measurement*1: D.Index Aortic valve measurement: AV(2D)
Pulmonary valve annulus diameter measurement
B/D mode PV Annulus
Blood flow volume measurement *1: F.Volume, SV/CO TAVI/TAVR measurement: TAVI/TAVR
Right ventricular diameter measurement:
CF mode RV Dimension, RV(2D)
Blood flow volume measurement: Flow Profile*2 Left atrial diameter/aortic diameter measurement
*1: Auto trace is possible. LA/AO
*2 Option: SOP-ARIETTA850-7 Myocardial wall thickness ratio measurement: Ratio
Left ventricular myocardial mass measurement
Application measurements LV Mass(AL), LV Mass T-E, LV Mass Pedi, LV Mass Pedi
Abdominal measurements Simpson*2
B mode Inferior vena cava diameter measurement: IVC
Gallbladder measurement: Gallbladder Left atrial/right ventricle volume measurement*4
Gallbladder wall thickness measurement: GB Wall-T LA Vol., RA Vol.
10
ARIETTA850DI-V50
Right ventricular function measurement*2: FAC Transverse Ao Doppler, Abdominal Ao Doppler
Blood Flow Measurement of a Defect Hole for Congenital
M mode Heart Disease*2: ASD, VSD, PDA, PFO
Left ventricular function measurement*5 Coronary measurement*7
Pombo, Teichholz, Gibson prox LAD(Rest), prox LAD(Peak), distal LAD(Rest),
Mitral valve measurement: Mitral Valve, MV(M) distal LAD(Peak), RCA(Rest), RCA(Peak), LCX(Rest),
Tricuspid valve measurement: Tricuspid Valve LCX(Peak), Graft(Rest), Graft(Peak),
Pulmonary valve measurement: Pulmonary Valve Coronary1,2,3(Rest)(Peak), Coronary Stenosis
Left atrial diameter/aortic diameter measurement*6 Asynchrony measurement
LA/AO AV Async., InterV.Async., TDI PW Time to Onset, TDI
Inferior vena cava diameter measurement: IVC PW Time to Peak
Asynchrony measurement: IntralV.Async.
Measurement of tricuspid annular plane systolic CF mode
excursion(TAPSE): M TDI measurement
TAPSE M TDI mFS, M TDI WT(LVPW), M TDI MT(IVS)
Right ventricular measurement: RV(M) *1: Auto or Full Auto measurement is possible.(Option: SOP-
ARIETTA850-74 is necessary for Full Auto measurement.)
D mode *2: Auto measurement is possible.(Option: SOP-ARIETTA850-74
Left ventricular ejection flow measurement*7 is necessary for Auto measurement.)
LVOT Flow, LVOT *3 Option: SOP-ARIETTA850-58, PEU-LISENDO880
Aortic stenosis flow measurement*7: AS Flow, AV *4: Auto or Full Auto measurement is possible.(Option: SOP-
Aortic valve regurgitation flow measurement*7 ARIETTA850-74 is necessary when Auto or Full Auto
AR Flow, AR measurement.)
Right ventricular ejection flow measurement*7 *5: Caliper Mark Auto Shift is possible.
RVOT Flow *6: Auto measurement is possible.(Option: SOP-ARIETTA850-74
Pulmonary stenosis flow measurement*7 and PEU-LISENDO880 is necessary when Auto measurement.)
PS Flow, PVA, PV, PA *7: Auto trace is possible.
Pulmonary valve regurgitant flow measurement*7 *8: Option: PEU-LISENDO880 is necessary for Doppler Trace
PR Flow, PR method.
Left ventricular inflow measurement*7*8
Trans M Flow, MV, MV Valsalva Vascular measurements
Mitral annulus diameter measurement: MV Annulus B mode
Mitral stenosis flow measurement*7: MS Flow Carotid Artery:
Mitral regurgitant flow measurement*7: MR Flow Stenosis measurement
Tricuspid annulus diameter measurement: TV Annulus Carotid %STENO-D, Carotid %STENO-A
Tricuspid inflow measurement: TV, TV Valsalva mean-IMT measurement: mean-IMT, CmeanIMT*1
Tricuspid stenosis flow measurement*7: TS Flow Max-IMT measurement
Tricuspid valve regurgitant flow measurement*7 max-IMT, IMT-Cmax, IMT-Imax, IMT-Bmax
TR Flow, TVA(VTI), TVA(pV) IMT Automatic measurement:
Pulmonary vein flow measurement: PV Flow CCA_IMT, ICA_IMT, ECA_IMT, BIF_IMT
PISA measurement IMT-C10 measurement: IMT-C10, IMT-C10 Auto*1
MR Vol. PISA, AR Vol. PISA, TR Vol. PISA, PR Vol. PISA Upper Ext Artery:
TDI PW measurement*7*8 Stenosis measurement
TDI PW MW, TDI PW1, TDI PW2, M Annulus(m), M Upper %STENO-D, Upper %STENO-A
Annulus(l), M Annulus(s), T Annulus(s), T Annulus(l) Lower Ext Artery:
MPI measurement: LV MPI, RV MPI, RV MPI(Tissue) Stenosis measurement
Aorta measurement*2 Lower %STENO-D, Lower %STENO-A
Ascending Ao Doppler, Descending Ao Doppler,
11
ARIETTA850DI-V50
D mode M mode
Carotid artery blood flow measurement Left ventricular function measurement: LV Function
CCA proximal, CCA mid, CCA distal, ICA, ECA, BIFUR, Fetal heart rate measurement: FHR, PreHR, PstHR
VERT
Upper extremity artery blood flow measurement D mode
ScA, AA, BA, DBA, BasA, RA, UA, SPA Blood flow measurement
Lower extremity artery blood flow measurement Umbilical Artery, MCA, Uterine Artery, Descending
CIA, EIA, IIA, CFA, DFA, SFA, PopA, PerA, ATA, PTA, Aorta, Renal Artery
DPA Left(right) ventricular ejection flow measurement:
Transit time of vessel flow(TVF) measurement*2 LVOT Flow, RVOT Flow
TVF_CFA, TVF_POP, TVF_ATA, TVF_PTA, TVF_PA Preload index measurement: PLI
Upper extremity venous blood flow measurement Ductus venosus measurement: Ductus Venosus
IJV, ScV, CV, AV, BV, DBV, BasV, RV, UV Fetal heart rate measurement: FHR, PreHR, PstHR
Lower extremity venous blood flow measurement
CIV, EIV, IIV, CFV, DFV, SFV, GSV, PopV, PerV, LSV, Others
ATV, PTV Supports multiple pregnancy examination
Transcranial artery blood flow measurement *1 Auto measurement is possible.
ACA, MCA, PCA, BA, VA, TICA, ACoA, PCoA *2 Caliper Mark Auto Shift is possible.
*1: IMT Auto measurement is possible. *3 Option: SOP-ARIETTA850-72
*2 Option: SOP-ARIETTA850-47, PEU-LISENDO880 *4: in real time
*5 Option: SOP-ARIETTA850-71
Small parts measurements
B mode Gynecology measurements
Lesion measurement(for breast use): Lesion(Breast) B mode
Aspect ratio measurement: D/W ratio Uterus measurement: Uterus
Papilla-tumor distance measurement: NT dist Endometrial thickness measurement: Endom-T
Thyroid gland volume measurement: Thyroid Volume Cervix measurement: Cervix
Thyroid isthmus thickness measurement Ovarian measurement: Ovary
Isthmus Thickness Follicular measurement: Follicles
Follicle volume measurement: Follicles Volume
D mode Bladder measurement: Bladder Volume
Artery measurement(for mammary blood flow)
Artery measurement(for thyroid blood flow) D mode
Uterine artery measurement: Uterine Artery
Obstetric measurements Ovarian artery measurement: Ovarian Artery
B mode
Gestational age measurement*1: GA Urological measurements
Fetal wight measurement: FW B mode
Ratio measurement: Fetus Ratio Prostate measurement: PSA Volume, PRS Slice Vol.
Amniotic fluid index measurement Seminal vesicle measurement: Seminal Vesicles
AFI*2, AF Pocket, AFV, MVP Bladder measurement: Bladder Volume
Cardiothoracic ratio measurement: CTAR, CTR Testicular measurement: Testis Volume
Cervical length measurement: Cervix Renal measurement: Renal Volume
Nuchal translucency measurement: Auto NT*1 Cortical measurement: Cortex Thickness
Automatic measurement of fetal heart rate*1*3 Adrenal measurement: Adrenal
Auto FHR, Auto FHR+*4
Automatic measurement of fetal fractional D mode
shortening*1*5: Auto FS Arterial blood flow measurement: Renal Artery
12
ARIETTA850DI-V50
Report functions
Measurement report
Abdominal measurement report
Cardiac function measurement report
Vascular measurement report
Small parts measurement report
Obstetric measurement report
Gynecology measurement report
Urological measurement report
Recall past measurement reports.
Plot examination data history on the report.
Direct printout of each report with an optional PC
printer.
Output of measurement values in CSV file is possible.
Others
Playback measurement
Assign measuring functions to the alphabet keys on the
keyboard.
User's Calculation: Combine basic measurement
functions such as distance, area and flow velocity to
create index calculation formulas for measurement
packages.
It is possible to create measurement packages that
contain a total of 30 calculations per application.
Reserved Word: Measurement parameter names for
application measurements, or user-registered
measurement names that can be used in User's
Calculation.
60 reserved words can be registered for each
application.
Font size of measurement result
3 kinds(x1, x1.2, x1.4)
13
ARIETTA850DI-V50
Optional Functions Global LV twist and LV torsion calculation
PC printer Automated workflow allows analysis can be started
It is possible to printout Abdomen, cardiology, vascular, without user interaction.
small parts, OB/GYN, and urology report screens including Displacement and strain analysis
ultrasound images directly with an external PC printer. Longitudinal, circumferential and radial component
analysis
Cardiac 3D(4D)* Principal tangential strain and 3D displacement
Cardiac 3D(4D) function provides the capability to display analysis
Cardiology 3D image and to display dual image(reference Segmental peak, time to peak and global average
image and biplane image) simultaneously by using TTE values in result table
2D array probe. Segmental parameter over time chart display
・ Scanning rate: Up to 999 volumes/sec Rotation and twist analysis
・ Biplane Mode(Color) Twist, Rotation Base, Rotation Apex
・ 3D Zoom Mode(Color) Segmental parameter over time chart display
・ Active 3D Mode(Color) * Option: SOP-ARIETTA850-112
・ Wide Angle 3D Mode(Color) This option is manufactured by TOMTEC Imaging System GmbH
・ Live 1,2,3,4,5,6 beat 3D volume imaging
・ Live 1,2,3,4,5,6,7 beat 3D color volume imaging 4D RV-Function*
・ It is possible to display 3 arbitrary sections Semi-Automated quantification of the Right Ventricle
simultaneously. Fast and easy Workflow
・ MPR(Multi-planar Reconstruction) Automatic contour proposal - no laborious contour
・ Auto Rotation drawing
・ 2 click cropping operation RV surface model
・ 3D Cropping 4D Review and Analysis
・ Display Layout(Single, Dual, Quad, MSI) Real-time interactive 4D model(Beutel) display of
・ Multi slice Image ventricle
・ Function to change 3D Imaging Parameter Display of 2D ultrasound slices(SAX and LAX) with
・ Change MPR View to operate by drag Beutel contours as overlay
・ Density(Both Lateral and Elevation) Graph displays for global volumes over time
・ Performance mode(Function to control the frame rate Display of result window with derived parameters
and volume rate to adjust the temperature at the probe Measurements
tip.) Global volumes over time
・ Change Plane Angle to observe arbitrary cross-section. Calculation of EDV, ESV, EF, SV
* Option: SOP-ARIETTA850-129, EU-9207, PEU-LISENDO880 Right ventricular longitudinal strain(RVLS)
free wall
iEF* septum
iEF calculates Biplane EF with full automated ED/ES frame Additional 2D measurements
detecting and full automated A2C and A4C contour TAPSE
tracing of biplane images acquired from a transthoracic FAC
2D matrix probe. RVDd base(RVD1)
* Option: SOP-ARIETTA850-120, SOP-ARIETTA850-74, SOP- RVDd mid(RVD2)
ARIETTA850-129, EU-9207, PEU-LISENDO880 RVLd(RVD3)
* Option: SOP-ARIETTA850-113
4D LV-Analysis* This option is manufactured by TOMTEC Imaging System GmbH
Additional features to 4D LV-Function
Polar plot with parametric display for all parameters. 4D MV-Assessment*
Dynamic(amplitude) and static(time to peak) parametric Semi-Automated Annulus and Leaflet Detection
display for all parameters. Fast and easy Workflow
14
ARIETTA850DI-V50
Semi automatic annulus detection Spatio-Temporal Image Correlation(STIC): Captures
Automatic and dynamic MV model generation via volume data in B mode or Color Doppler mode via a
object segmentation slow scan.
Automatic measurements for annulus, leaflets and Rendering Mode
coaptation Surface Sharp: Displays images that mix Surface(3D
Morphological and functional analysis views images with a smooth texture) and Sharp(3D
Analysis screen for 4D presentation of tissue and images with a detailed texture) effects.
annular structures Surface MIP: Displays a mixed image composed of a
Transparence rendering to display all objects within surface image and MIP(maximum intensity
tissue projection: A 3D image at its highest echo intensity
Definition and display of surgical and ventricular view as seen from the viewpoint) image.
orientations Surface X-ray: Displays a mixed image composed of
Display of B/W tissue and Doppler color information a surface image and an X-ray(a 3D image averaged
in all views echo data seen from the viewpoint) image.
Adjustable cut plane(D’Art) 4Dshading: Displays realistic 3D images with light
Color texture on leaflet models that represents their and shadow that look like endoscopic images.
topology 4Dshading Flow: Displays realistic color Doppler 3D
4D Reconstruction Mode images with shadows, similar to optical images.
Real-time rendering 4Dtranslucence: Displays 3D images in which the
Interactive 4D cube for data presentation and surface contour of the target has been enhanced.
manipulation 3D Image Display Mode
4D rendering of B/W tissue and color Doppler data 3D/4D: Displays cross-sectional and 3D images.
3D visualization of automatic measurements Free Axis of MPR(FMPR): Standard reference points
Hybrid 4D display of measurements and grayscale can be moved, and the cross-sectional image
data displayed.
Interactive display settings for optimum display Multi Slice Imaging(MSI): Displays multiple cross-
Separate settings for threshold and transparency sections reconstructed from volume data.
Generic manual measurements Volume Slice Imaging(VSI): Displays 3D images of
Further general features volume data of arbitrary thickness at a specific axis.
On-screen help Curved MPR(CMPR): Displays cross sections on an
Planimetry layout for individual MPR adjustment arbitrary curve or straight line from the volume data.
Carpentier segmentation labels on leaflet surface Measurements
Measurements Cross-sectional images: Distance, circumference,
Manual measurements such as distance, angle, and area, etc. can be measured in the same way as
curve and area with general B mode images. (except for STIC)
Static and dynamic annular measurements 3D Image: Measurements are possible in CMPR
Static and dynamic leaflet measurements mode(distance, circumference) and VSI
Static and dynamic coaptation measurements mode(distance).
* Option: SOP-ARIETTA850-114 Auto Clipper: This function makes automatic
This option is manufactured by TOMTEC Imaging System GmbH adjustments to achieve an appropriate Clipper
configuration to display a fetal in 3D image.
RT-3D(4D)* 3D image quality adjustment: Lower Threshold, 3D HI
Method for acquiring volume data REZ, Inversion Mode
4D(real-time 3D): Captures volume data in a * Option: EU-9184, SOP-ARIETTA850-4
continuous B mode scan.
HI Definition 3D: Captures volume data in B mode. Real-time Tissue Elastography*1
Color 3D: Captures volume data in color Doppler It is a function to visualize the stiffness of a tissue in real-
mode. time. The strain generated in a tissue on applying
15
ARIETTA850DI-V50
pressure is represented by colors. Measures the propagation velocity of shear waves in
(It is available to change Elastography color map) the target region.
Elasto mode ROI setting function
Overlapping display of Elastography on B-mode A trackball can be used to change the position of the
image. ROI you select to measure.
Dual Elasto mode Automatic recording of still images
Dual image display of Elasto mode, possible to select The instrument can be set up to automatically send
different color map on each side. results after measurements.
Real-time biplane Integration with measurement functions
Elasto mode overlapping display of Elastography on B- Measurement data is saved for each selected
mode image of either cross-section, in the function to measurement. You can modify a measurement during
display B-mode image with the one of different cross- an examination.
section simultaneously. Data saved to CSV files
Strain Ratio measurement Measurement data is saved in a CSV file.
Calculation of ratio of strain between arbitrary 2 Attenuation measurement(iATT)*2
regions. Simultaneously with the measurement of Vs, the
Assist Strain Ratio ultrasound attenuation(ATT) is measured near the
Clicking center of the tumor automatically sets the center of the ROI.
measurement ROI to the tumor and the fatty layer Combi-Elasto is possible.
(the mammary gland region and lesion are targeted). *1 Option: SOP-ARIETTA850-151
Strain Graph *2: It is only available with C251 and C252 probe.
The time variation of distorted average value is
displayed on a graph in real time. Shear Wave Elastography*
Auto Select Frame It is a function for measuring the propagation velocity of
The frame under stable pressure is chosen shear waves and the stiffness, and creating images of the
automatically. 2D distribution of propagation velocity. The propagation
Strain Histogram Measurement*2 velocity of shear waves varies according to tissue
Displays a histogram which shows the values of hardness.
relative strain within an ROI and calculates the Shear Wave Elastography(SWE) mode
quantitative characteristics of the elasticity image and You can superimpose shear wave propagation
Liver Fibrosis Index. velocities in color on B mode images. The color SWE
Compatible to RAW data image appears inside the SWE ROI.
Guide of displacement direction ROI setting function
Display the direction of displacement of the liver This function lets you use the trackball to adjust the
caused by the heart beat in real time. position of the measurement ROI.
HI Strain SWE measurement
Performs the strain calculations based on multiple You can measure the propagation velocity of shear
frames, and displays the most stable elasticity image. waves within a single or multiple arbitrary regions.
*1 Option: SOP-ARIETTA850-43 Measurement starts when the image is frozen.
*2 Option: SOP-ARIETTA850-60 * Option: SOP-ARIETTA850-151
16
ARIETTA850DI-V50
* Option: SOP-ARIETTA850-43, SOP-ARIETTA850-60, SOP- image section.
ARIETTA850-151 Last registration
It is possible to return just before the condition of
Automated FHR Measurement* registration.
Set measurement ROI on fetal heart plane in B mode Reset function
image and measures heart rate automatically. It is possible to return initial condition of registration.
* Option: SOP-ARIETTA850-72. Built-in magnetic sensor*2
Displaying fused virtual images*3
Automated FS Measurement* By fusing a parts image or color image of the
It is Possible to automatically extract the fetus left SYNAPSE VINCENT analysis image to the CT or MRI
ventricle inside diameter shortening rate(FS). base image, you can use the fused image as a virtual
* Option: SOP-ARIETTA850-71 image in an RVS examination.
3D Sim-Navigator*4
Real-time Virtual Sonography*1 3D Sim-Navigator is an auxiliary function provided by
This function is able to synchronize the volume data the Real-time Virtual Sonography(RVS) software.
which was previously acquired by CT, MRI, PET, or US Displays the puncture guideline on virtual images
and in real-time US image. Navigator view(3-screen)
The magnetic position sensor is installed on the probe to Displays C-plane image
determine the position and angle of the probe. Registration of needle marks
As a result, the display of cross sections that match Displays distance between multiple needle marks
ultrasound images is enabled, allowing you to use the E-field Simulator *5
cross sections as a reference for your ultrasound A color map superimposed on the CT image simulates
diagnosis. the distribution of electric current from the given
The same section of ultrasound image and CT/MR/PET location of the multiple electrodes.
image or US volume data is displayed as real time by Needle Tracking*6
acquiring the position information on the probe from a Tracks and displays the needle tip location in real time
magnetic sensor and reconstructing MPR(Multi Planer during RFA procedures.
Reconstruction) image from CT/MR/PET image and US Body Motion Tracking*7
volume data. The omniTRAX Active Patient Tracker (manufactured
In various diagnosis areas(liver, breast and prostate) by CIVCO) provides automatic image registration of
examination is possible as it supports convex type, linear fused images using real time ultrasound with
type, intracavital probe. previously acquired CT; with the synchronized status
Moreover, it can use together with Real-time Tissue adjusted when small patient movements occur.
Elastography. *1 Option: EU-9185B or later, EZU-RVF1B, PM-AR850-H004,
Monitor Display: SOP-ARIETTA850-62
Dual: Virtual / US *2 Option: PM-AR850-H006(Probe dependent)
Quad: Virtual / US / Virtual / Virtual *3 Option: SOP-ARIETTA850-97
Overlay: Virtual + US *4 Option: SOP-ARIETTA850-75
Magnetic field quality display *5 Option: SOP-ARIETTA850-96
3D body mark display: ON/OFF *6 Option: SOP-ARIETTA850-84, EU-9197
3D body mark size: 3 kinds *7 Option: SOP-ARIETTA850-85, EU-9197
Marking function
Multi-volume function 2D Tissue Tracking(2DTT)*1
Max. 4 CT/MR/PET/US images for retrieving, saving It is an application for evaluating the thickness and
and the display switching movements of the myocardium.
US-US RVS function Analysis
US volume data generated beforehand can be Free use
displayed as Virtual image in the same to US real-time Analyzes the changes in distance between any two
17
ARIETTA850DI-V50
points and angular variation from the initial time Tissue Doppler Imaging(TDI) analysis*
phase. It performs velocity analysis of the data acquired in the
SAX TDI mode.
Analyzes differences in thickness between various B-mode
regions of the myocardium, as well as angular Temporal VP: Displays a graph of the motion velocity
variation with the center of gravity point, based on distribution in the area specified in the myocardium.
left ventricular short axis images. Regional VP: Displays a graph of the motion velocity
Apex-S*2 distribution on a trace line arbitrarily specified in the
Calculates the Longitudinal Strain and Transverse myocardium.
Strain of each region of the left ventricle based on Strain Rate: Displays a graph of the Strain Rate time
the apex image. The global strain of the variations in a graph.
endocardium trace is also calculated. Strain: Displays a graph of the Strain time variations
Apex-V*2 in a graph.
Calculates the volume, ejection fraction, center of Myocardial Thickness: The changes in myocardial
gravity and velocity of volume change of the right thickness in the time direction of the designated
and left ventricles and atrium based on the apex endocardium and epicardium movement within the
image. myocardium are automatically traced and displayed
View in a graph. The Strain in that area can also be
SAX displayed.
SAX, Basal SAX, Mid SAX, Apical SAX Output as a CSV file: Possible
APEX-S, -V * Option: SOP-ARIETTA850-13
4ch, 4ch Inv, 2ch, 2ch Inv, 3ch, 3ch Inv
Graph Type Contrast Harmonic Imaging(CHI)*
Line Graph: Displays analysis results for each ROI It is a function that displays images more visibly by dying
chronologically in line graphs. them with an ultrasound contrast agent.
Color Graph: Displays a list the analysis results for Settings ideal for Low, Mid, and High acoustic pressure
each ROI into the colors corresponding to the color are selectable for each contrast agents.
bar. CHI Method for CHI mode:
Line & Color Graph: Displays Line Graph and Color Wide-band Contrast Harmonic Imaging (WbC): The
Graph up and down. Pulse Inversion method enables retrieval of echoes
Bull’s eye: When the view is assigned, the analysis from the ultrasound contrast agent across a broad
results for each ROI are displayed with color and spectrum and display them in CHI mode at a high
numerical values in a Bull’s-eye image. level of sensitivity.
Measurements Tissue Reduction Contrast Harmonic Imaging (TrC):
Point to Point: Measures the difference between two The Amplitude Modulation method makes it possible
points on a graph. to reduce signals from tissue to get clearer CHI
Time to Peak: Measures various values of any three mode images.
time phases and the difference between them. CHI Mode image:
3 point: Measures various values of any three time CHI-B/W: Displays signals from the ultrasound
phases and the difference between them. contrast agent as black-and-white images.
Distance: Measures the distance between any two CHI-Color: Displays signals from the ultrasound
points on an image. contrast agent as color images.
*1 Option: SOP-ARIETTA850-49 CHI-eFLOW: Displays signals from the ultrasound
*2: It is possible to perform fully automatic measurements using contrast agent on power Doppler images.
2D tracking method such as Global Longitudinal Strain or SAX Tx Mode:
radial strain and ejection fraction measurements by a single click Monitor Mode: Displays the monitor image and CHI
operation in combination with multiple settings. mode image side by side.
Flash: This mode sends high acoustic pressure
18
ARIETTA850DI-V50
transmissions at set intervals to destroy the time it takes to reach -6 dB or -3 dB from the
ultrasound contrast agent. maximum value of the graph, and measures the
One-shot: This mode sends and receives a single time width between the intersection points on either
shot of an ultrasound signal at high acoustic pressure side of the maximum value.
in response to a manual operation. Distance: Measures the distance between any two
Frame Rate Limit points on an image.
Limits the frame rate to prevent ultrasound waves Inflow Time Mapping(ITM) Measurement: Measures
from breaking down the contrast agent. the number and proportion of color pixels at each
Overlay display time interval in an ITM image.
Body motion compensation by Motion Compensated Area Under the Curve(AUC) Measurement: Measures
Mode is possible. the area under the curve for a section on the graph.
* Option: SOP-ARIETTA850-44 Output as a CSV file: Possible
* Option: SOP-ARIETTA850-44
Contrast Harmonic Imaging(CHI) analysis*
It is a function that lets you display the data collected in EyeballEF*
CHI mode as a Time Intensity Curve or analyze it in the Selection of apical four-chamber view(A4C) and apical
form of Subtraction images. two-chamber view(A2C) and tracing endocardium surface
Analysis automatically, and measure heart volume, ejection
・ Time Intensity Curve(TIC) fraction(EF), and Global Longitudinal Strain(GLS) using M.
Displaying a graph of the temporal changes in the Simpson method.
average(or median, maximum, or mode) intensity Revising Items:
of the region of interest(ROI). Specifying a cross section
Types of graph: Setting heartbeat analysis
By ROI: Displays graphs for all frames in Tracing an end-diastolic image
chronological order. Specifying an end systolic frame
By Frame Number: Displays a graph for each Tracing an end-diastolic image
frame number in a unit. * Option: SOP-ARIETTA850-58, PEU-LISENDO880
Inflow Time Mapping(ITM)
This function focuses on the difference between eTRACKING*
ultrasound contrast agent inflow times and It is a function to calculate arteriosclerosis indices such as
colorizes changes in brightness across the entire the pressure-distortion elastic constant(Ep) and the
range of the moving image. stiffness parameter(β), which indicate the elastic
Subtraction characteristics of the blood vessel based on the blood
Display subtraction images that represent the vessel diameter and blood pressure values of the carotid
difference between frames. artery.
Measurement Stiffness parameter(β) analysis results:
Point to Point: Measures the difference between two beta: Stiffness parameter
points on a graph. Ep: Pressure-distortion elastic constant
SD: Measures the analysis data for the specified time AC: Arterial compliance
phase(Time, Max, Average, Medium, Mode, or SD). AI: Augmentation Index
Wash-in: Measures the rise time of the graph from PWVbeta: Regional pulse wave velocity
the minimum and maximum values. DATmax: Maximum Distension Acceleration Time
Wash-out: Measures the fall time of the graph from Output as a CSV file: Possible
the minimum and maximum values. Blood pressure value is necessary for this examination.
Fitting: Displays an approximated curve based on * Option: SOP-ARIETTA850-11, PEU-LISENDO880
the start and end points, and measures the degree
of increase in the signal strength. Flow Mediated Dilatation(FMD) analysis*
FWHM(Full Width at Half Maximum): Calculates the It is used for the functional assessment of vessels before
19
ARIETTA850DI-V50
organic changes, such as vessel wall thickening and
plaque formation, are manifested.
In an FMD test, blood flow volume is increased
noninvasively, and changes in blood flow velocity and
vessel diameter are recorded precisely for long periods of
time.
Echo Tracking technology is used to capture and record
changes in the state of the vessel at three stages such as
baseline, during a vascularization and dilatation after the
cuff deflation, to assess FMD.
Output as a CSV file: Possible
Blood pressure value is necessary for this examination.
* Option: SOP-ARIETTA850-16(includes eTRACKING software),
PEU-LISENDO880
Wave Intensity(WI)*
Wave Intensity (WI) has been proposed as an indicator to
allow simple determination, based on the forms of the
blood pressure waveforms and velocity waveforms at any
point in the arterial system, of which is predominant, the
forward-traveling wave heading from the heart to the
periphery, or the backward-traveling wave returning from
the periphery to the heart.
Wave Intensity analysis:
Wave Intensity: Wave Intensity index value
Arterial Stiffness: Index values for assessing the
hardness of the blood vessel
Diameter: Distension waveform
Flow Velocity: Blood flow velocity measurement
value
Output as a CSV file: Possible
Blood pressure value is necessary for this examination.
* Option: SOP-ARIETTA850-34 (includes eTRACKING software),
PEU-LISENDO880
20
ARIETTA850DI-V50
General Specifications Resolution: WXGA++(1600x900)
Acoustic Power Output
0 to 100% DVI-D digital
Resolution: WXGA++(1600x900)
Preset Function Digital video with HDMI connector*
100 kinds(Max. 10 kinds per each probe) Resolution: FHD(1920x1080), XGA(1024x768),
Preset contents storable in USB memory VGA(640x480)
Quick Scanning Selector(Q.S.S.) * Option: EU-9205
Image modifying parameters (e.g. Gain, frequency, ・ Analog Video Input/Output
depth) of your choice can be registered. (Up to 4 sets Input
per preset) ・ Y/C: 1 channel
These parameters can immediately be registered and Output
selected by touch panel during examinations. Color composite (BNC): 1 channel
Preset is booted up in conjunction with ID information Y/C: 1 channel
(BodyParts or etc.) ・ Network: LAN(Wired, Wireless)
・ Others
Characters and graphic displays ・ Audio (L/R): 2 channels (Output 1, Input 1)
Character input area
ID, name, age, sex, retained text Storage
(Can be corrected after exam.) ・ SSD
・ Input is possible with virtual keyboard on LCD panel ・ HDD
・ Automatic Annotation Labeling
800 words(User registration is possible. 10 classes.) Viewing Monitor
・ Body mark: ・ 22 inch Organic EL monitor(OLED)
38 kinds are available per each region. ・ Resolution: FHD(1920 x 1080)
6 regions+1 user is able to register. ・ Tilt and swivel are possible.
Probe mark: 4 kinds ・ Height adjustment and swivel together with operation
Display position: changeable panel.
Fetus mark
Rotatable(Only single horizontal fetus marks) Safety Regulation
・ Assist line display IEC 60601-1 Ed.3.0: 2005, IEC 60601-1 Ed.3.1: 2012
Class I, Type BF
Menu control
・ 10.4-inch color TFT LCD touch panel Environmental Requirements
In Operation
Active Probe Ports Temperature: +10 to +40 degrees C
・ For electronic scanning probes: 6 (4 active, 2 parking) Relative Humidity: 30 to 75%(non condensing)
・ For independent probes*: 1 Atmospheric pressure: 700 to 1060 hPa
* Option: EU-9187B Altitude: Up to 3000 m
In Storage/Transportation
Input/Output Signals Temperature: -10 to +50 degrees C
・ Data Input/Output (0 to +50 degrees C for mechanical probes)
・ USB2.0: 5 channels Relative Humidity: 10 to 90%(non condensing)
(Main unit 2+ Operation Panel 3) Atmospheric pressure: 700 to 1060 hPa
・ USB3.0: 1 channel
・ Digital Video Input/Output Power Requirement
Input 100 to 120/ 200 to 240 V ±10%, 50 or 60 Hz,
・ DVI-D digital: Max. 1300 VA(with optional recorders connected)
21
ARIETTA850DI-V50
Max. 900 VA(main unit only)
Shut down tool
Hibernation*
*: The condition is saved even if the power is unplugged.
Dimensions
55 cm(W) × 90 cm(D) ×122 to 169.5 cm(H)
Weight
Main unit only: 145 kg±10%
Main unit and all optional equipment: 163 kg±10%
22
ARIETTA850DI-V50
System Configuration
23
ARIETTA850DI-V50
24
ARIETTA850DI-V50
OPTIONAL PROBES
Electronic convex sector probes
Application Frequency Scanning angle
Model Optional accessories
(description) range (MHz) (degrees)
Abdominal C22K 6.0-1.0 82 Puncture Adapter
MP-2781
MP-2781-5
MP-2781-25
Bracket
614-108, 614-109(CIVCO)*1*5
Abdominal C22P 6.0-1.0 74 Needle Guide Bracket
EZU-PA7C2*1
MP-2824
Magnetic Position Sensor Attachment(Standard)
RV-012*2
Abdominal C23 6.0-1.0 110* Verza Bracket
644-095, 644-096(CIVCO)*1*5
BX2 Needle Guide
644-094(CIVCO)*1*5
Magnetic Position Sensor Attachment
RV-017*2
Waterproof Case
WP-001
Abdominal C23RV 6.0-1.0 110* Verza Bracket
644-095, 644-096(CIVCO)*1*5
BX2 Needle Guide
644-094(CIVCO)*1*5
Magnetic Position Sensor Attachment
RV-017*3
Waterproof Case
WP-001
Abdominal C251 5.0-1.0 70 Bracket
644-082, 644-083(CIVCO)*1*5
Magnetic Position Sensor Attachment
RV-004*2
Abdominal C252 6.0-1.0 150** Bracket
644-082, 644-083(CIVCO)*1*5
Magnetic Position Sensor Attachment
RV-004*2
Abdominal C25P*4 5.0-1.0 70 Biopsy Attachment
EZU-PA7B1-1
EZU-PA7B1-2
EZU-PA7B1-3
EZU-PA7B1-4
EZU-PA7B1-C
Magnetic Position Sensor Attachment
RV-005*2
Abdominal C35 8.0–2.0 110* Bracket
644-082, 644-083(CIVCO)*1*5
Magnetic Position Sensor Attachment
RV-004*2
Transvaginal・ C41B 10.0-2.0 200 Puncture Guide Tube
Transrectal MP-2445
Magnetic Position Sensor Attachment
RV-013*2
Waterproof Case
WP-001
25
ARIETTA850DI-V50
Transrectal C41RP 9.0–2.0 180 Puncture Guide Tube
MP-2452-G18(Standard:2pcs)
MP-2452-G21/-G16/-G14(Option)
Waterproof Case
WP-001
Transvaginal C41V1 10.0-2.0 200 Puncture Adapter
EZU-PA7V
Magnetic Position Sensor Attachment
RV-002*2
Abdominal C42 8.0-4.0 80 Needle Guide Bracket
EZU-PA532
Bracket
644-077, 644-078(CIVCO)*1*5
Magnetic Position Sensor Attachment
RV-006*2
RV-007(for EZU-PA532)*2
Intraoperative C42K 10.0-4.0 65 Puncture Adapter
MP-2458
Bracket
614-068, 614-100(CIVCO)*1*5
Intraoperative C42T 10.0-3.0 65 Magnetic Position Sensor Attachment
RV-003*2
Waterproof Case
WP-001
Abdominal C421 12.0-3.0 100* Verza Bracket
644-098, 644-099(CIVCO)*1*5
Magnetic Position Sensor Attachment
RV-017*2
Waterproof Case
WP-001
*When Wide Scanning is ON.
**When Wide Scanning PLUS is ON.
27
ARIETTA850DI-V50
Bi-plane probe
Application Frequency range Scanning angle
Model Optional accessories
(description) (MHz) (degrees)
Transrectal CC41R 8.0-4.0 100/120 Puncture Adapter
EZU-PA5V
Puncture Guide Fixture
EZU-PA3U
Magnetic Position Sensor Attachment
RV-010*2
Waterproof Case
WP-001
Transrectal CC41R1 10.0-2.0 180/180 Puncture Adapter
EZU-PA5V
Magnetic Position Sensor Attachment
RV-015*2
Waterproof Case
WP-001
Transrectal C41L47RP Convex 8.0-4.0 200 Puncture Guide Fixture
Linear 10.0-5.0 64mm EZU-PA3U
Magnetic Position Sensor Attachment
RV-011*2
Transrectal CL4416R Convex 10.0-2.0 180 Puncture Guide Fixture
Linear 14.0-2.0 63mm BA-001
Magnetic Position Sensor Attachment
RV-011*2
Waterproof Case
WP-001
Transrectal CL4416R1 Convex 10.0-2.0 200* Puncture Adapter
Linear 14.0-2.0 63mm BA-001
Magnetic Position Sensor Attachment
RV-021*2
Waterproof case
WP-001
*When Wide Scanning is ON.
28
ARIETTA850DI-V50
Electrical Radial Probes
Frequency Scanning angle
Application Model Optional accessories
range (MHz) (degrees)
Transrectal R41R 10.0-5.0 360 Waterproof Case
WP-001
29
ARIETTA850DI-V50
Probes and available functions
Basic Functions
Compound
eFocusing PLUS
DeepInsight
Trapezoid
Wide Scanning
Wide Scanning PLUS
B steer
eFocusing
Acoustic Noise Reduction
Real-time Biplane
OMNI mode
FAM
TGC Enh(B)
TGC Enh(Color)
TDI mode
HI Frame(B)
HI Frame(Color)
Puncture Guide Line
Needle Emphasis
Brachy Grid Display
CW mode
Assist Line
THI(FmT)
THI(WbT)
THI(HdT)
Dual Gate Doppler
STIC
Stress echo
C22K
C22P
C23
C23RV
C251
C252
C25P
C35
C41B
C41RP
C41V1
C42
C42K
C42T
C421
CC41R
CC41R1
R41R
L31KP
L34
L35
L43K
L441
L44K
L46K1
L51K
L53K
30
ARIETTA850DI-V50
Compound
eFocusing PLUS
DeepInsight
Trapezoid
Wide Scanning
Wide Scanning PLUS
B steer
eFocusing
Acoustic Noise Reduction
Real-time Biplane
OMNI mode
FAM
TGC(B)
TGC(Color)
TDI mode
Hi Frame(B)
Hi Frame(Color)
Puncture Guide Line
Needle Emphasis
Brachy Grid Display
CW mode
Assist Line
THI(FmT)
THI(WbT)
THI(HdT)
Dual Gate Doppler
STIC
Stress echo
L44LA
L44LA1
L55
L64
SML44
S121
S31
S42
S3ESL1
S3ESEL
S3ESCLS
VC34
VC35
VC41V
MXS1
C41L47RP(CV)
C41L47RP(LN)
CL4416R(CV)
CL4416R(LN)
CL4416R1(CV)
CL4416R1(LN)
UST-2265-2
UST-2266-5
31
ARIETTA850DI-V50
Optional Functions
CHI(Low)
CHI(Mid)
CHI(High)
Panoramic
RTE
SWM
iATT
SWE
RVS
Needle Tracking
Cardiac 3D
Real time 3D
eTRACKING
FMD
Wave Intensity
CHI-eFLOW
DFI mode
C22K
C22P
C23
C23RV
C251
C252
C25P
C35
C41B
C41RP
C41V1
C42
C42K
C42T
C421
CC41R
CC41R1
R41R
L31KP
L34
L35
L43K
L441
L44K
L46K1
L51K
L53K
32
ARIETTA850DI-V50
CHI(Low)
CHI(Mid)
CHI(High)
Panoramic
RTE
SWM
iATT
SWE
RVS
Needle Tracking
Cardiac 3D
Real time 3D
eTRACKING
FMD
Wave Intensity
CHI-eFLOW
DFI mode
L44LA
L44LA1
L55
L64
SML44
S121
S31
S42
S3ESL1
S3ESEL
S3ESCLS
VC34
VC35
VC41V
MXS1
C41L47RP(CV)
C41L47RP(LN)
CL4416R(CV)
CL4416R(LN)
CL4416R1(CV)
CL4416R1(LN)
UST-2265-2
UST-2266-5
33
ARIETTA850DI-V50
34
ARIETTA850DI-V50
・ The specifications are subject to change without notice.
・ The standard components and optional items differ depending on the country.
Not all products are marketed in all countries.
Please contact your local FUJIFILM Healthcare Corporation distributors for details.
・ ARIETTA, DeepInsight, HdTHI, eFocusing, HI REZ, Carving Imaging, Real-time Tissue Elastography, Real-
time Virtual Sonography, 4Dshading and LISENDO are registered trademarks or trademarks of FUJIFILM
Healthcare Corporation in Japan and other countries.
・ ALOKA is a registered trademark or trademark of Nippon RayTech Co., Ltd. in Japan and other countries.
・ McAfee is a registered trademark or trademark of McAfee LLC in the United States and other countries.
・ DICOM is a registered trademark of the National Electrical Manufacturers Association in the United States
for its standards publications relating to digital communications of medical information.
・ Excel is a registered trademark or trademark of Microsoft Corporation in the United States and other
countries.
・ SYNAPSE and VINCENT are registered trademarks or trademarks of FUJIFILM Corporation in Japan and
other countries.Ueno
・ TOMTEC, LV-Function, Beutel and D’Art are registered trademarks or trademarks of TOMTEC Imaging
Systems GmbH in Germany and other countries.
・ This document is applicable to ARIETTA 850
35
ARIETTA850DI-V50