0% found this document useful (0 votes)
29 views4 pages

Man MVB DS

The MVB Divider Valve is designed to accurately dispense lubricant to up to 20 outlets at pressures up to 3600 psi, with a fixed output of 0.17cc per cycle. It operates in a progressive manner, ensuring consistent discharge as long as lubricant flow is maintained. The valve features customizable outlet configurations and is available with optional cycle indicators for monitoring system operation.

Uploaded by

technique
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views4 pages

Man MVB DS

The MVB Divider Valve is designed to accurately dispense lubricant to up to 20 outlets at pressures up to 3600 psi, with a fixed output of 0.17cc per cycle. It operates in a progressive manner, ensuring consistent discharge as long as lubricant flow is maintained. The valve features customizable outlet configurations and is available with optional cycle indicators for monitoring system operation.

Uploaded by

technique
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MVB Divider Valve

Series Progressive Systems

General
The MVB Divider Valve accurately meters and dispenses lubricant to as many as 20 outlet lines at
operating pressures up to 3600 psi. Output volumes are fixed at 0.17cc (0.01 cu. in.) per cycle but
can be combined with other outlets by using appropriate fittings for larger outputs. Valves are
available with cycle indicator pins to provide visual confirmation of system operation. In addition the
cycle pin can be fitted with a switch to provide electrical feedback to a system controller.

Operation
Operational sequence of a MVB Divider Valve is defined as “progressive,” meaning that each valve
segment completes its piston stroke, discharging a positive volume of lubricant to the point it
serves before the following valve segment operates. As long as lubricant is supplied under pressure
to the inlet of the divider valve, these segments will continue to operate in a progressive manner.
The divider valves will always follow a constant discharge pattern. When lubricant flow ceases, the
pistons will stop. Whenever flow resumes, the pistons will start again at the same point in the
discharge cycle.

Features
++ Flexible design allows for on-site configurations
++ Valves available in sizes ranging from 6 to 20 outlets
++ Positive displacement discharge
++ One switch monitors complete system
++ Valves are corrosion resistant

Technical Data
Lubricant Grease NLGI grade 000-2
Synthetics Contact factory prior to use
Discharge/Cycle/Outlet 0.17cc (0.01 cu. in.)
Minimum Pressure 145 psi (10 bar)
Maximum Pressure 4350 psi (300 bar)
Maximum Differential Pressure 1015 psi (70 bar)
(between two opposite outlets)
Operating Temperature Range -13˚F to 176˚F (-25˚C to 80˚C)
Material Carbon steel with surface protection
Surface Protection Proprietary, 1000-hour salt spray

BIJUR DELIMON INTERNATIONAL


(919) 465 4448 LOCAL
(800) 631 0168 TOLL-FREE
(919) 465 0516 FAX
www.bijurdelimon.coM/MOBILE
2100 Gateway Centre Blvd., Suite 109
Morrisville, NC 27560

1 35479 • R2 03/09
Monitoring
MVB Divider Valves are available with visual
OPTIONAL
cycle pin and optional cycle switch for electrical CYCLE SWITCH
feedback (sold separately).

Configuring Outlets
The MVB requires the use of special fittings and/or closure plugs to configure a specific outlet
arrangement. All divider valves are supplied with non-configured outlets on each side and can be
converted to working outlets by using fittings or plugs, as shown on page 3. Using the appropriate
fitting or plug allows you to combine multiple outlets to meet higher output requirements.
Closure plugs can also be used to reduce the number of working outlets. See chart below for outlet
code descriptions.

Code Outlet Type Description Sample Configuration Done On-site


b a a b a Standard or conventional tubing adapters
a Working Outlet is equipped with special
OUTLET 1 OUTLET 3 OUTLET 5 OUTLET 7 OUTLET 9 are not appropriate.
tube fitting. 0.17cc 0.17cc 0.17cc
1
b Closed Lubricant ported to opposite Set screw (Part #22104-12)
outlet, same segment. (Internal Ball (Part #22084-13)
set screw and ball 1 removed, SET
SCREW
2
Code “c” porting is not possible for the
unused outlet fitted with special INLET
end segment.
closure plug and clamping ring;
see required accessories on
page 3.)
c Closed Lubricant ported to adjacent
segment, away from the inlet 0.34cc 0.17cc 0.51cc 0.17cc
OUTLET 2 OUTLET 4 OUTLET 6 OUTLET 8 OUTLET 10
segment, same side. (Unused a a c a a
outlet fitted with closure plug and
copper seal; see required
accessories on page 3.)2

How to Order
MVB

Number of Outlets End Segment


06— 6 outlets 001— With cycle pin
08— 8 outlets 002— Without cycle pin
10— 10 outlets
12— 12 outlets
14— 14 outlets
16— 16 outlets
18— 18 outlets
20— 20 outlets
BIJUR DELIMON INTERNATIONAL

The MVB Divider Valve features a smart part number ordering system. Choose the number of outlets (919) 465 4448 LOCAL
(800) 631 0168 TOLL-FREE
and the type of end segment. For example: To order a 6 outlet divider valve with a cycle pin, you would (919) 465 0516 FAX
use Part #MVB06-001. www.bijurdelimon.coM/MOBILE
2100 Gateway Centre Blvd., Suite 109
Morrisville, NC 27560

2 35479 • R2 03/09
Outlet Fittings and Accessories
Item Description Part #
1 Outlet fittings Compression 1/4” O.D. TBG outlet fittings with check valve 35166
1/4” O.D.TBG outlet fittings without check valve 35362
3/16” O.D. TBG outlet fittings with check valve 35360
3/16” O.D. TBG outlet fittings without check valve 35361
6mm O.D. TBG outlet fittings with check valve 23301
Quick connect 1/4” O.D. TBG outlet fittings with check valve 29080
1/4” O.D. TBG outlet fittings without check valve 29082
Outlet Fitting
3/16” O.D. TBG outlet fittings with check valve 29084
3/16” O.D. TBG outlet fittings without check valve 29086
4mm O.D. TBG outlet fittings with check valve 23405
6mm O.D. TBG outlet fittings with check valve 23407
Outlet adapter 1/8” O.D. NPT(F) outlet fitting with check valve 29076
1/8” O.D. NPT(F) outlet fitting without check valve 29078
2 Closure plug – “b” porting (singling) 47874
3 Clamping ring – “b” porting (singling) 47872
4 Closure plug – “c” porting 47883
5 Copper seal – “c” porting 25589-2
“b” Porting – Closure Plug & Clamping Ring
2 3

4 5

“c” Porting – Closure Plug & Copper Seal


Accessories
Description Part #
For additional accessories,
see Brochure #35544: Mobile
MVB bracket 35417
Accessories Catalog.
MV-B BRACKET

1/4-20 Grade 8 – 2.5” bolt 35538


1/4-20 Grade 8 – 2.5” Nylon locknut 35539
Mechanical cycle switch 47877-4
BIJUR DELIMON INTERNATIONAL
Proximity cycle switch (NPN) 47877-5
Proximity cycle switch with LED (NPN) 66925S003* (919) 465 4448 LOCAL
(800) 631 0168 TOLL-FREE
Cable, Straight, 10 meters long 76928-2863 (919) 465 0516 FAX
Cable, 90°, 10 meters long 76928-2833 www.bijurdelimon.coM/MOBILE
* Use with cable part #76928-2863 or #76928-2833 2100 Gateway Centre Blvd., Suite 109
Morrisville, NC 27560

3 35479 • R2 03/09
Dimensional Schematics Measurements shown in millimeters
unless otherwise noted.

* Refer to page 3 for tubing connections


15 1/8” NPT 20 7.1 and accessories.

6
Ø7.1

12 11

10 9
M10x1*

8 7

6 5

4 3

15
2 1

15

52 (max) 60
8 72
30

Outlets (qty) L
6 60mm
8 75mm
10 90mm
12 105mm
14 120mm
16 135mm
18 150mm
20 165 mm

BIJUR DELIMON INTERNATIONAL


(919) 465 4448 LOCAL
(800) 631 0168 TOLL-FREE
(919) 465 0516 FAX
www.bijurdelimon.coM/MOBILE
2100 Gateway Centre Blvd., Suite 109
Morrisville, NC 27560

4 35479 • R2 03/09