TUF- 2000M Ultrasonic Flow Module/ RTU
This ultrasonic
module is inline
measurement for long-
term.The convertor and
transducer are installed
fixing on the pipe, with
the advantages of small
Clamp on Insertion Pipe
Features
High Accuracy
Better than ±1 %
Wide Measuring Range
Several types transducer for selection, pipe size from Dn 15 mm to Dn 6000 mm
High Reliability
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
Strong Anti- interference
Dual- balance signal differential receiver/ driver circuit to avoid interference of converter,
TV tower, high voltage l ine etc.
Powerful Recording Function
A u t o m at i c a l l y r ecor d the fo l l owing dat a:
1. The totalizer data of the last 512 days/128 months/10 years
2. The time and corresponding flow rate of the last 64 times of power on and off events
3. The working status of the last 32 days
Far t r a n sm i s s i o n d i s t ance, easy for n e t wo r k i n g
RS485 support wireless network, connect GPRS module to accomplish wireless transmission .
Support Heat Measurement
。o n n e c t t h e t e m p e r a t u r e t r a n s d u c e r , c a n f i n i s h t h e h e a t / e n e r g y m e a s u r e m e n t
C
Ⅴ- 1
TUF- 2000M Ultrasonic Flow Module/ RTU
Liquid Type
This flowmeter can be virtually applied to a wide range of measurement. A variety of
liquid applications can be accommodated: ultra-pure liquids, potable water, chemicals, raw
Measuring Diagram
Flow Measurement Heat Measurement Features
No need to cut off water , no pressure loss
Supply Pipe Easy for installation
Connect clamp on temperature transducer,
can finish the heat/energy measurement
Return Pipe
Clamp on
No need to cut off water , no pressure loss
Stable and reliable for long term operation
Supply Pipe
Connect Pt100 temperature transducer,
can finish the heat/energy measurement
Return Pipe
Insertion
Need to cut off pipe
With high accuracy and stability
Supply Pipe
Connect Pt100 temperature transducer,
can finish the heat/energy measurement
Return Pipe
Pipe
Applications
Water supply and drainage Heating Construction of Energy-saving Metallurgy Petrochemical Power
Ⅴ- 2
TUF- 2000M Ultrasonic Flow Module/ RTU
Optional Transducers
Types Picture Spec. Model Measurement Range Temperature Dimension
Small Size TS- 2 DN15~DN100 - 30~ 90℃ 45×25×32mm
Clamp on Medium Size TM- 1 DN50~DN700 - 30~ 90℃ 64×39×44mm
Large Size TL- 1 DN300~DN6000 - 30~ 90℃ 97×54×53mm
Small Size TS- 2- HT DN15~DN100 - 30~ 160℃ 45×25×32mm
High temp Medium Size TM- 1- HT DN50~DN700 - 30~ 160℃ 64×39×44mm
.
clamp on Large Size TL- 1- HT DN300~DN6000 - 30~ 160℃ 97×54×53mm
Standard TC- 1 DN80~DN6000 - 30~ 160℃ 190×80×55mm
Insertion
Lengthen TC- 2 DN80~DN6000 - 30~ 160℃ 335×80×55mm
π type G3 DN15~DN25 - 30~ 160℃
Pls refer to
Pipe Standard G2 DN32~DN40 - 30~ 160℃ detailed pipe
dimensions
Standard G1 DN50~DN6000 - 30~ 160℃
Optional Temperature Transducers
Picture Specification Model Meas. Range Temperature Cut of water Accuracy
Clamp on temperature
Transducer Pt100 CT- 1 ≥DN50 - 40~ 160℃ No
Insertion temperature
Transducer Pt100 TCT- 1 ≥DN50 - 40~ 160℃ Yes
100℃ ± 0.8℃
Insertion Pt100
Installation with pressure PCT- 1 ≥DN50 - 40~ 160℃ No
Insertion Pt100
SCT- 1 DN50 - 40~ 160℃ Yes
Small size pipe diameter
Parts Descriptions
Front View Wiring Dragram Back View
TX2 T2 GN T1 TX1 AI5 AI4 AI3 OCT1- OCT1+ RLY- RLY+
24V+ 24V- 485+ 485- AO-IN AO UP+ UP- GND DN+ DN- GND
Dimensions:92×90×34mm Installation Method:
LCD Display:60×19mm Guide Rail(width is 35mm)
4 keyboard operation
Ⅴ-3
TUF- 2000M Ultrasonic Flow Module/ RTU
Datasheet
Items Performance & Parameter
Principle Transit- time ultrasonic flowmeter
Accuracy ±1%
Operation 4 keyboards operation
1 way 4~ 20mA output, electric resistance 0~ 1K,accuracy0. 1%
Signal
Convertor Output 1 way OCT pulse output( Pulse width 6 ~ 1000 ms,default is 200 ms)
1 way Relay output
Signal 3 way 4~ 20mA input, accuracy 0. 1%,acquisition signal such as temperature, press and liquid level
Input Connect the temperature transducer Pt100, can finish the heat/energy measurement
Data Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS
Interface
Special Cable Twisted-pair cable, generally, the length under 50 meters; Select the RS485, transmission distance can over 1000m
Pipe Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed
Material
Pipe Pipe
Installation 15~ 6000mm
Diameter
Condition
Straight
Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump
Pipe
Single liquid can transmit sound wave,
such as Water (hot water, chilled water, city water, sea water, waste water, etc.);
Type of Sewage with small particle content; Oil ( crude oil, lubricating oil, diesel oil, fuel oil, etc.);
Measuring Liquid Chemicals ( alcohol, etc.); Plant effluent; Beverage;
Medium Ultra- pure liquids, etc.
Temperature - 30~ 160℃
Turbidity No more than 10000ppm and less bubble
Flowrate 0~±7m/ s
Temperature Convertor:- 20~ 60℃;Flow Transducer:- 30~ 160℃
Working
Environment Humidity Convertor: 85%RH;Flow Transducer:can measure under water,water depth≤2m(tansducer sealed glue)
Power Supply DC8~ 36V or AC85~ 264V(optional)
Power
Consumption 1. 5W
Dimension 95*95*35MM(Convertor)
Ordering code
Flow Pipe Cable Temperature
Transducer Diameter Material Pressure Length Transducer
TUF- 2000M- - DN mm - -- MPa ----- m --
TS- 2 0 Carbon Steel None
TM- 1 1 Stainless Steel CT- 1
TL- 1 2 Cast Iron TCT- 1
TS- 2- HT 3 Glass Fiber reinforced PCT- 1
TM- 1- HT 4 PVC SCT- 1
TL- 1- HT 5 Cement
TC- 1 6 Others
TC- 2
G
Example: TUF -2000M+TM -1+DN300+0+1 . 6MPa+ 10m+ PCT- 1
PS: Standard confirguration = TUF -2000M (convertor)+TM- 1 + 5 M cable +Steel belt( DN200)+Couplant(1 pc)
Ⅴ- 4