0% found this document useful (0 votes)
24 views

0.6_Structure

The document provides detailed specifications and construction notes for a manhole and stormwater drain, including dimensions, materials, and reinforcement requirements. It emphasizes adherence to contract specifications and relevant standards, such as IS:456 for concrete and IS:1786 for reinforcement. Key features include the use of M30 grade concrete, TMT steel reinforcement, and specific guidelines for construction joints and waterproofing measures.

Uploaded by

sourav.banerjee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views

0.6_Structure

The document provides detailed specifications and construction notes for a manhole and stormwater drain, including dimensions, materials, and reinforcement requirements. It emphasizes adherence to contract specifications and relevant standards, such as IS:456 for concrete and IS:1786 for reinforcement. Key features include the use of M30 grade concrete, TMT steel reinforcement, and specific guidelines for construction joints and waterproofing measures.

Uploaded by

sourav.banerjee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MANHOLE OPENING

(750x600) @ 50m C/C GENERAL NOTES


250x150mm PVC ENCAPSULATED 1. ALL THE DRAWINGS SHALL BE READ IN CONJUCTION WITH
FOOTREST (TYP)
CONTRACT SPECIFICATIONS.
750 2. ALL DIMENSIONS ARE IN MILLIMETER AND LEVELS ARE IN METERS,
UNLESS NOTED OTHERWISE. DO NOT SCALE. FOLLOW WRITTEN
DIMENSIONS ONLY
3. THE STRUCTURAL CONCRETE SHALL BE OF GRADE M30. ALL
REINFORCED CONCRETE WORKS SHALL CONFORM TO IS:456 &
TECHNICAL SPECIFICATIONS.

B1 (300x450)
4. CONSTRUCTION JOINTS IN THE WALLS SHOWN ARE INDICATIVE
ONLY. THE CONTRACTOR MAY DECIDE OTHER APPROPRIATE
600 LOCATIONS TO SUIT AT SITE AFTER APPROVAL OF THE SITE
B1

DRAIN 10 T @150 C/C INCHARGE. THE CONTRACTOR SHALL USE SUITABLE WATER
600Wx600D (TYP)
02 PROOFING COMPOUND AS APPROVED BY THE ENGINEER.
- 5. HORIZONTAL CONSTRUCTION JOINT TO BE PROVIDED AS MARKED
200mm RCC WALL 10 T @150 C/C
(TYP) (TYP) IN THE DWG. ADDITIONAL CJ TO BE PROVIDED ONLY AFTER PRIOR
APPROVAL FROM ENGINEER IN CHARGE.
BEAM B1 REINFORCEMENT
1. ALL REINFORCEMENT BARS SHALL BE TMT STEEL CONFORMING TO
01
- 10 T @150 C/C
IS:1786 OF GRADE Fe500S or 415S/D, CRS.
(TYP) 2. IF REQUIRED, REINFORCEMENT CAN BE MARGINALLY SHIFTED OR
MANHOLE PLAN BENT TO CLEAR OPENING, EMBEDMENTS ETC.
3. MINIMUM LAP LENGTH, DEVELOPMENT LENGTH SHALL BE 50 TIMES
125 THICK OF THE DIAMETER OF SMALLER BAR UNLESS NOTED OTHERWISE.
PRECAST COVER 4. COVER TO ANY REINFORCEMENT BAR INCLUDING LINKS, UNLESS
NOTED OTHERWISE, SHALL BE = 45mm & DRAIN COVER SLAB=
FGL 25mm.
3nos-T16 5. NOT MORE THAN 50% OF THE BARS SHALL BE LAPPED AT ANY
300
TYPICAL RCC DETAIL SECTION.
OF MANHOLE 6. PLACE GREATER OF THE REINFORCEMENT IN LAYER 01 & 02 IN THE
OUTER MOST LAYER.

(VARIES)
2800
7. REINFORCEMENT SHALL BE FIRMLY SUPPORTED ON APPROVED
CHAIRS/ CONCRETE BLOCKS TO BE

450
2L-T8@125mm C/C
10 T @125 C/C PLANNED BY CIVIL CONTRACTOR.
(TYP)
8. LAP SPLICES IN BEAMS & COLUMNS TO BE PROVIDED AS
250x150mm PVC RECOMMENDED IN IS 13920.
ENCAPSULATED 9. WHEREVER LAPS ARE PROVIDED, THE SPACING OF STIRRUPS IN
FOOTREST (TYP) BEAMS SHOULD NOT EXCEED 150 mm, & THE TIES IN COLUMNS
3nos-T16
SHOULD NOT EXCEED 100 mm.
TYPICAL RCC DETAIL
150

STRUCTURAL STEEL
300

200mm WIDE GRAVEL OF BEAM MKD. B1


OR CRUSHED STONE 1. GRADE OF STEEL SHALL BE OF E250, CONFORMING TO IS:2062
NEAR WEEP HOLES AS 10 T @125 C/C
WEEP HOLE
600

(TYP) 2. ALL FILLET WELDS ARE 4 mm. FILLET UNLESS OTHERWISE NOTED.
(TYP) PER MORTH SPECTION
(TYP.) 3. ALL WELDING SHALL BE AS PER IS:318
10 T @125 C/C BLINDING CONCRETE
RCC WALL DRAIN (TYP)
1. BLINDING CONCRETE SHALL BE OF M15 GRADE, 100MM THICK,
(TYP)
PROJECTING 100 MM BEYOND THE FACE OF FOOTING, UNLESS
200

SHOWN OTHERWISE.
2. ALL LOOSE DEBRIS/ ROCKS/ SOIL BELOW THE RAFT TO BE
REMOVED & FILLED WITH BLINDING CONCRETE.

75 THK. PCC (M15) COMPACTED 300


EARTH (TYP)
100 300 200 600 200 300 100
TYPICAL RCC DETAIL OF
STORM WATER DRAIN
(600Wx600D)
(SCALE 1:20)
TYPICAL DETAIL OF
STORM WATER DRAIN
(600Wx600D)
MAP NOTE:
1. Project Co-ordination System, UTM Zone 46N, Datum WGS 84.

STATUS:
Submission
250 / 300 CLIENT:
= 75 =
8 T @ 150 C/C URBAN DEVELOPMENT
BAR 12Ø LIFTNG
HOOK (TYP.) DEPARTMENT,
(TYP.)
250

GOVT. OF NAGALAND

40
MIN. 4.0mm THK. MS CONSULTANT:

125
STRIP ALL AROUND
BAR 12Ø LIFTNG
HOOK (TYP.)
SMEC India Pvt Ltd
FGL
1st Floor, Novus Tower,
West Wing, Plot Number - 18, Sector - 18,
250 / 300 Gurugram - 122015 (Haryana), India

PROJECT TITLE:
SECTION 3-3
(SCALE 1:10) ADB LOAN NO. 54166-001/6045/2022
3 NOS. 8 T
500 500 NAGALAND URBAN INFRASTRUCTURE
DEVELOPMENT PROJECT
1000 / 1150

(TYP.) (TYP.)

3 NOS. 8 T
NAME OF TOWN :
MIN. 4.0mm THK. 8 T @ 150 C/C
MS STRIP ALL Mokokchung
AROUND
SECTION 4-4
(TYP.)
500

(SCALE 1:10) DRAWING TITLE:


40
PRECAST COVER GA & RCC DETAILS OF STORM
(TYP.)

MS FLAT 50X3 THK.


WATER DRAIN (600Wx600D)
500

LUGS WITH SPLIT


TAIL @400 C/C
3 3 SOURCE:

125
4 4 230MM WIDE PVC RIBBED
COMPACTED 75 THK. P.C.C. PDMC NAGALAND
WATER BAR WITH CENTRAL MIN. 4.0mm THK. MS
SOIL/EARTH (M15) FILE LOCATION:
BULB (ALL AROUND). 50Ø WEEP STRIP ALL AROUND
HOLES (TYP.)
40 SMEC/NGL/MokokI/SWD/001
PROJECT CODE: SIZE: REV NO: DATE:
TYPICAL DETAIL OF EXPANSION JOINT 7061672 A2 R0 JAN-2025
TYPICAL DETAILS OF TYPICAL RCC DETAIL OF TYPICAL VIEW OF WEEP DETAIL OF MS STRIP
AT EVERY 40m. LENGTH DRAWN BY DESIGNED BY CHECKED BY ISSUED BY SCALE:
PRECAST COVEAR PRECAST COVER HOLES IN WALLS ALL AROUND COVER SLAB
(SCALE 1:20)
(SCALE 1:20) (SCALE 1:20) (SCALE 1:40) (SCALE 1:10) 1:20
M.P K.K S.B R.D

You might also like