User Manual
User Manual
Carbon monoxide
Low value 50PPM
High value 150PPM
Range 1000PPM
Figure 3
When the information is displayed, the system will enter the
self-test and the light self-test status, that is, the light
will flash twice; self-test of the vibrating piece means that
the vibrating piece will generate vibration and then stop;
the self-test of sound means that the bee sounder will beep
twice. The status mentioned above indicates that the
peripheral self-test has passed if normal. See Figure 4,
Figure 5 and Figure 6.
Voice
self-inspection
Figure 6
4.2 Normal status of detection and alarm
If the detector does not detect a gas above the concentration
of the low alarm value, the screen will normally display the
current detection value of the gas. For example, carbon
monoxide gas is shown in Figure 7.
Carbon monoxide
0 PPM
Figure 7
When the detector detects a lower limit alarm value that is
higher than that of any one of the gases, the detector will
alarm, and the backlight of the screen will light up, and
at the same time, the vibrating piece will also start to
vibrate. The detector will stop beeping and vibrating only
when the gas concentration is normal, and the backlight of
the screen will turn off.
Turn off?
Yes No
Figure 9
4.5 Charging
When the detector is in the normal detection state, the
battery voltage is lower than 3.5V, it will display the
message “Low battery, please charge”. At this time, you
need to insert the USB charging cable to charge immediately.
Otherwise, the system may not work properly due to the low
voltage. See Figure 10
Low battery
Please charge
Figure 10
It can also be charged in the off state, and the charging
will display “Charging...”. See Figure 11
charging
Figure 11
When charging is over, “Ok” will be displayed.See Figure
12
Charging
finished
Figure 12
5、Menu guide
(1) On the menu: press the middle button to the main
menu
(2)On keys: Press the left button in the menu to select
up, cancel or press the right key to select the function.
Press the middle button to confirm, save or enter the
submenu.
(3)If the system doesn’t work for more than 5
seconds, the system automatically returns to the normal
detection.
Main menu
Menu Method of operation:
Press the left key to
﹣﹥Zero setup select the menu item,
Gas calibration press the right key to
to select the menu,
Warning setup press the middle
button to enter the
menu, and if you
Menu choose to exit, the
normal detection will
﹣﹥Alarm record be back again.
Time setup
Language switch
Menu
﹣﹥Exit
▲ enter ▼
Zero trim
Zero fine-tuning In fact, this
function is available
-0000 to change the set
* value based on the
actual gas
▲ enter concentration.
▼ Operation
method: Enter the zero
fine adjustment
interface. When the
gas type is selected,
press the middle key
to enter the zero
trim. Press the left
key to the right to
choose the value or
symbol. Press the
right key to adjust
the current sign or
value. Press the
middle button to save
the adjustment.
For example,
when the value of
carbon monoxide in the
air is always
displayed as 3 not 0,
you can set -0004 and
then save it. Return
to the normal
detection interface.
At this time, the
value of the carbon
monoxide is zero.
Note: the
setting value is
slightly larger than
the displayed value by
1 unit. If too large,
the display value will
be too different from
the actual gas
concentration, as a
result of being not
accurate.
Calibration
Input Password To prevent users from
affecting the work of
0000 the portable gas
* detector. This
feature sets a
▲ enter ▼ separate password.
Alarm settings
Low value High value This function is
used to set the alarm
limit when detecting
0050 0200 gas concentration.
The low alarm refers
* * to an audible and
▲ enter ▼ visual alarm when the
gas concentration
exceeds the low value.
The high alarm refers
to an audible and
visual alarm when the
gas concentration
exceeds the high
value.
Method of operation:
Enter the
high-low-value
adjustment, press the
left button to adjust
each number. Press the
right key to adjust
the number. Press the
middle key to save it.
Alarm record
Alarm record The "Alarm Record"
menu consists of
﹣﹥View alarm "Alarm View", "Alarm
Alarm clear Clear", and "Exit".
Method of operation:
▲ enter ▼ Press the left key to
select the submenu,
and press the right
Alarm record one to select the
﹣﹥Exit submenu. When the gas
type is selected,
press the middle
﹣﹥Exit button to enter the
nest menu.
Alarm view
To view the
previous alarm
records.
Press the left key
to view the latest
record and press the
Carbon monoxide right one to view the
last record. Exit
00-00-00 automatically without
Time: 00:00 operation for 5
seconds.
Low value 50
▲ ▼
Alarm clear
To clear alarm
records
Alarm clear Method of operation:
Press the left key to
select“Yes”to clear
YES NO the alarm record;
press the right one to
select“No”to cancel
the action.
Exit
Alarm record To exit the submenu of
Alarm Logging
﹣﹥Exit Method of operation:
Press the middle key
to exit.
▲ enter ▼
Time setting
Please enter the year To set the current
time.
0000 Method of operation:
* Enter the "Time
Settings" and display
▲ enter ▼ the year setting.
Press the left key to
Please enter the elect the last two
digits, and press the
month right one to adjust
00 them.Press the middle
button to save it,
* then enter the month
setting, and so on.
▲ enter ▼
When you enter the
minute setting, press
Please enter date the middle button to
save all information
00 before exiting.
*
▲ enter ▼
Language switching
Language switch This function is
used to switch
﹣﹥Chinese language, including
English Chinese, English, and
Exit.
▲ enter ▼ Method of operation:
Press the left key to
select the downward
Language switch language, press the
﹣﹥Exit right one to select
the upward language,
and press the middle
▲ enter ▼ one to confirm it.If
you select the
English, the system
language will switch
to it. To select
Chinese in the English
interface, and the
system language will
switch to Chinese.If
you choose to exit,
the submenu will
appear again.
Warning: please do not charge the portable gas detection
alarm at the inspection site to avoid fire or explosion.
Please do not charge the portable gas detector when it is
turned on, so as not to affect the charging speed.
8、Store
The detector shall be stored at the temperature of -10 °
C to 55 ° C and a relative humidity of less than 85%, and
where there is no harmful gases or impurities in the air that
corrode the detector.