Data sheet                                                                                                                 6XV1873-6CN10
product type designation                                        FO Trailing Cable
 product description                                             Glass fiber-optic cable, preferred length, preassembled
                                                                 FO Trailing Cable 50/125, pre-assembled with 2x2 SC connectors, length 10 m.
 suitability for use                                              Flexible cable for use in cable carriers for high mechanical loading, no UL
                                                                  approval
 version of the assembled FO cable                                Preassembled with four SC connectors
 cable designation                                                AT-W(ZN)Y(ZN)11Y 2G 50/125 OM2++
 wire length                                                      10 m
optical data
 attenuation factor per length
      ● at 850 nm / maximum                                       2.7 dB/km
      ● at 1300 nm / maximum                                      0.7 dB/km
 bandwidth length product
      ● at 850 nm                                                 600 GHz·m
      ● at 1300 nm                                                1200 GHz·m
mechanical data
 number of fibers / per FOC core                                  1
 number of FO cores / per FOC cable                               2
 version of the FO conductor fiber                                Multi-mode gradient fiber 50/125 µm, OM 2
 design of the FOC core                                           Hollow core, filled, diameter 1400 µm
 design of the fiber-optic cable                                  segmentable
 outer diameter
      ● of the optical fibers                                     50 µm
      ● of the optical fiber sheath                               125 µm
      ● of the FOC core sheath                                    2.9 mm
 symmetrical deviation / of the outer diameter of the FOC core    0.1 mm
 sheath
 outer diameter / of the cable                                    10.5 mm
 symmetrical deviation / of the outer diameter of the line        0.5 mm
 material
      ● of the fiber-optic cable core                             Quartz glass
      ● of the optical fiber sheath                               Quartz glass
      ● of the FOC core sheath                                    PVC
      ● of the fiber-optic cable sheath                           PUR
      ● of the strain relief                                      Aramid fibers
 color
      ● of the FOC core sheath                                    orange/black
      ● of cable sheath                                           green
 bending radius
      ● with single bend / minimum permissible                    150 mm
      ● with multiple bends / minimum permissible                 200 mm
 number of bending cycles                                         5000000
6XV18736CN10                                                                                                 Subject to change without notice
                                                                 9/25/2024
Page 1/3                                                                                                                © Copyright Siemens
 tensile load
      ● during installation / short-term                              2000 N
      ● during operation / maximum                                    800 N
 short-term shear force per length                                    700 N/cm
 continuous shear force per length                                    400 N/cm
 weight per length                                                    90 kg/km
ambient conditions
 ambient temperature
      ● during operation                                              -40 ... +80 °C
      ● during storage                                                -40 ... +80 °C
      ● during transport                                              -40 ... +80 °C
      ● during installation                                           -5 ... +50 °C
 fire behavior                                                        flammable
 chemical resistance
      ● to mineral oil                                                acc. to IEC 60811-404 with test oil IRM 902 (acc. to ISO 1817), +100 °C, 168 h,
                                                                      pull speed 250 mm/min
      ● to grease                                                     resistant
 radiological resistance / to UV radiation                            resistant
 protection class IP                                                  IP20
product features, product functions, product components / general
 product feature
      ● halogen-free                                                  No
      ● silicon-free                                                  Yes
 product component / rodent protection                                No
 wire length
      ● for glass FOC / for 100BaseFX / for Industrial Ethernet /     5000 m
      maximum
      ● for glass FOC / for 1000BaseSX / for Industrial Ethernet /    750 m
      maximum
      ● for glass FOC / for 1000BaseLX / for Industrial Ethernet /    2000 m
      maximum
      ● for glass FOC / with PROFIBUS / maximum                       3000 m
standards, specifications, approvals
 certificate of suitability
      ● RoHS conformity                                               Yes
 reference code
      ● according to IEC 81346-2                                      WH
      ● according to IEC 81346-2:2019                                 WHA
further information / internet links
 internet link
      ● to website: Selection guide for cables and connectors         https://support.industry.siemens.com/cs/ww/en/view/109766358
      ● to web page: selection aid TIA Selection Tool                 https://www.siemens.com/tstcloud
      ● to website: Industrial communication                          https://www.siemens.com/simatic-net
      ● to web page: SiePortal                                        https://sieportal.siemens.com/
      ● to website: Image database                                    https://www.automation.siemens.com/bilddb
      ● to website: CAx-Download-Manager                              https://www.siemens.com/cax
      ● to website: Industry Online Support                           https://support.industry.siemens.com
security information / header
 security information                                                 Siemens provides products and solutions with industrial cybersecurity functions
                                                                      that support the secure operation of plants, systems, machines and networks.
                                                                      In order to protect plants, systems, machines and networks against cyber
                                                                      threats, it is necessary to implement – and continuously maintain – a holistic,
                                                                      state-of-the-art industrial cybersecurity concept. Siemens’ products and
                                                                      solutions constitute one element of such a concept. Customers are responsible
                                                                      for preventing unauthorized access to their plants, systems, machines and
                                                                      networks. Such systems, machines and components should only be connected
                                                                      to an enterprise network or the internet if and to the extent such a connection is
                                                                      necessary and only when appropriate security measures (e.g. firewalls and/or
                                                                      network segmentation) are in place. For additional information on industrial
                                                                      cybersecurity measures that may be implemented, please visit
                                                                      www.siemens.com/cybersecurity-industry. Siemens’ products and solutions
                                                                      undergo continuous development to make them more secure. Siemens strongly
                                                                      recommends that product updates are applied as soon as they are available
                                                                      and that the latest product versions are used. Use of product versions that are
                                                                      no longer supported, and failure to apply the latest updates may increase
                                                                      customer’s exposure to cyber threats. To stay informed about product updates,
                                                                      subscribe to the Siemens Industrial Cybersecurity RSS Feed under
6XV18736CN10                                                                                                     Subject to change without notice
                                                                     9/25/2024
Page 2/3                                                                                                                    © Copyright Siemens
                                                  https://www.siemens.com/cert. (V4.7)
Approvals / Certificates
  General Product Approval
                           Declaration of Con-                                   Manufacturer Declara-
                                 formity                                                 tion
  other                    Environment
     Confirmation             Confirmation
 last modified:                                   8/9/2024
6XV18736CN10                                                                              Subject to change without notice
                                                 9/25/2024
Page 3/3                                                                                             © Copyright Siemens