Voyager™
12½ - 25 Tons - 60 Hz
VoyagerTM . . . a proven performer built to For contractors, Voyager saves time and
provide ultimate indoor comfort. money, increasing their ability to win
Voyager continues to provide the highest jobs. It meets engineer’s design criteria
standards in quality and reliability, and offers solutions to cover many
comfort, ease of service, and the special applications. And, of course,
performance of Trane light commercial Voyager carries the Trane reputation for
products. excellence, quality and reliability.
Introduction 2
Features and Benefits 4
Application Considerations 8
Selection Procedure 9
Model Number Description 10
General Data 11
Performance Data 15
Cooling Performance 15
Fan Performance 21
Heat Performance 34
Controls 35
Electric Power 36
Dimension and Weights 54
Mechanical Specifications 65
RT-PRC002-EN 3
Features and
Benefits
Weather Tight Top and Cabinet • Actual shipping tests were performed Conversionless Units
• Voyager units incorporate either a one to determine packaging requirements. • The dedicated design units (either
piece top or the Trane-Tite-Top (T3). Units were test shipped around the downflow or horizontal) require no
Each part of the top (either two or three country to determine the best panel removal or alteration time to
pieces) overlaps in such a way that packaging. Factory shake and drop convert in the field — a major cost
water cannot leak into the unit. These tests were used as part of the package savings during installation.
overlapped edges are gasketed and design process to help assure that the
sealed to ensure superior water unit arrives at the job site in top • Horizontal units come complete with
condition. duct flanges so the contractor doesn’t
integrity. have to field fabricate them. These duct
• Quick- Access (12½-25 tons) panels • Rigging tests include lifting a unit into flanges are a time and cost saver.
reduce the number of possible water the air and letting it drop one foot,
entry points. assuring that the lifting lugs and rails U-shaped Airflow
hold up under stress.
• For added water integrity, Voyager has • U-shaped airflow allows for improved
a raised 11/8" lip around the supply and • We perform a 100% coil leak test at the static capabilities.
return of the downflow units to prevent factory. The evaporator and condenser
water from blowing into the ductwork. coils are leak tested at 200 psig and
pressure tested to 450 psig.
Quality And Reliability Testing • All parts are inspected at the point of
• The fan and idler arm assembly final assembly. Sub-standard parts are
designs have been tested to over identified and rejected immediately.
300,000 cycles each. Our combined • Every unit receives a 100% unit run test
cycle testing is now over 7,000,000 before leaving the production line to
cycles. make sure it lives up to rigorous Trane
• All of Voyager’s designs were requirements.
rigorously rain tested at the factory to
ensure water integrity. We test designs at our factory not on
our customers!
4 RT-PRC002-EN
Features and
Benefits
RT-PRC002-EN 5
Features and
Benefits
Standardized Components
• Components are placed in the same Low Voltage Connections
location on all Voyager units.
Familiarize yourself with one Voyager The wiring of the low voltage
and you are familiar with every connections to the unit and the zone
Voyager. sensors is as simple as 1-1, 2-2, and 3-3.
This simplified system makes it easy for
• ReliaTel can fit all Voyager Packaged the installer to wire.
Gas/Electrics, Cooling with Electric Quick-Adjust Idler Arm
Heat, and Heat Pump models. This Colored And Numbered Wiring
provides standardization of parts for You save time and money tracing wires With the Quick-Adjust Idler Arm, the belt
the contractors. Less money is tied up and diagnosing the unit. and sheaves on all 12½-25 tons can be
in inventory using the ReliaTel. quickly adjusted without moving the
VariTrac™ mounted fan motor. The result is a major
• Contractors/owners can stock fewer When Trane’s changeover VAV System savings in time and money.
parts due to standardized components for light commercial applications is
throughout Voyager units. coupled with Voyager, it provides the
Single Side Service latest in technological advances for
Single side service is standard on all comfort management systems and can
Voyager 12½-25 tons. allow thermostat control in every zone
served by VariTrac.
Quick-Access Panels On The 12½-25 Tons
Remove three or fewer screws for access
to the standardized internal components
and wiring.
VariTrac
6 RT-PRC002-EN
Features and
Benefits
ReliaTel
RT-PRC002-EN 7
Application
Considerations
8 RT-PRC002-EN
Selection
Procedure
RT-PRC002-EN 9
Model
Number
Description
T C D 1 5 0 C 3 0 0 A A
1 2 3 4 5 6 7 8 9 10 11 12
D = Downflow
H = Horizontal Digit 9, 10 - Factory-Installed Options
00 = No Factory-installed Options
Digits 4, 5, 6 - Nominal Gross Cooling 0A = Factory-installed Economizer
Capacity (MBh) 0B = Oversized Motor
0C = Downflow Economizer and
150 = 12½ Tons Standard Efficiency Oversized Motor
151 = 12½ Tons High Efficiency 0F = Trane Communications Interface
180 = 15 Tons Standard Efficiency (TCI)
181 = 15 Tons High Efficiency 0G = Downflow Economizer and TCI
210 = 17½ Tons Standard Efficiency 0H = TXV/Face-Split Evaporator
211 = 17½ Tons High Efficiency 0J = Oversized Motor and TXV/Face-Split
240 = 20 Tons Standard Efficiency Evaporator
241 = 20 Tons High Efficiency 0K = Downflow Economizer, Oversized
300 = 25 Tons Standard Efficiency Motor, and TXV/Face-Split Evaporator
301 = 25 Tons High Efficiency 0L = Downflow Economizer and TXV/Face-
Split Evaporator
10 RT-PRC002-EN
General (12½, 15 Ton)
Data Standard Efficiency
RT-PRC002-EN 11
General (17½, 20, 25 Ton)
Data Standard Efficiency
NOTES:
1. Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is
net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. 17½ - 20 ton models are certified in accordance with the Unitary
Large Equipment certification program, which is based on ARI Standard 340/360-93. 25 ton model ratings shown are tested in accordance with ARI Standard 340/360-93.
2. EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360.
3. Integrated Part Load Value is based in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb
at ARI rated cfm.
4. Sound Rating shown is tested in accordance with ARI Standard 270 or 370.
5. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
6. Refrigerant charge for horizontal models is 21.5/14.5 per circuit.
7. Optional two inch pleated filters are also available.
8. For 380V/60Hz units, the oversized motor is used as the standard motor. Refer to oversized motor data.
12 RT-PRC002-EN
General (12½, Ton)
Data High Efficiency
NOTES:
1. Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity
is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Large Equipment
certification program, which is based on ARI Standard 340/360-93.
2. EER is rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value is based in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb
at ARI rated cfm.
4. Sound Rating shown is tested in accordance with ARI Standard 270 or 370.
5. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
6. Face area for Indoor Coil on horizontal models is 12.36.
7. Horizontal models have 4 - 20 x 25 x 2 filters.
8. Optional two inch pleated filters are also available for 12½ ton models.
9. TXV/Face-Split Option (Downflow Only) TCD151C3,4,W (Refrigerant Control): Expansion Valve; (Refrigerant Charge): 13.4/12.0.
RT-PRC002-EN 13
General (15, 17½, 20, 25 Ton)
Data High Efficiency
NOTES:
1. Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is
net and includes the effect of fan motor heat. 15 - 20 ton models are certified in accordance with the Unitary Large Equipment certification program, which is based on
ARI Standard 340/360-93. 25 ton model ratings shown are tested in accordance with ARI Standard 340/360-93.
2. EER is rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value is based in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb
at ARI rated cfm.
4. Sound Rating shown is tested in accordance with ARI Standard 270 or 370.
5. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
6. Horizontal models have 8 - 20 x 25 x 2 filters.
7. Optional two inch pleated filters are also available.
8. TXV/Face-Split Option (Downflow Only) TCD181C3,4,W (EER):11.4; (System Power kW): 15.79; (Refrigerant Control): Expansion Valve; (Refrigerant Charge): 26.0/12.0
9. TXV/Face-Split Option (Downflow Only) TCD241C3,4,W (Gross Cooling Capacity):259,000; (ARI Net Cooling Capacity): 244,000; (System Power kW): 23.02;
(Refrigerant Control): Expansion Valve; (Refrigerant Charge): 21.5/22.2
10. TXV/Face-Split Option (Downflow Only) TCD211C3,4,W Refrigerant Charge): 27.0/10.0
11. TXV/Face-Split Option (Downflow Only) TCD301C3,4,W (EER): 10; (Gross Cooling Capacity): 294,000; (ARI Net Cooling Capacity): 272,000; (IPLV): 10.6; System Power kW):
27.2; Refrigerant Control: Expansion Valve; (Refrigerant Charge): 21.0/23.0
14 RT-PRC002-EN
Performance (12½, 15 Ton)
Data Standard Efficiency
Table PD-1 — Gross Cooling Capacities (MBH) 12½ Ton Three Phase TC*150D3, D4, DW, DK
Ambient Temperature
85 95 105 115
Enter
Dry Entering Wet Bulb
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 135.0 108.0 153.0 86.0 162.0 59.3 126.0 103.0 146.0 82.0 158.0 56.7 116.0 98.2 138.0 77.7 152.0 53.8 106.0 93.1 127.0 80.0 145.0 50.5
4500 80 136.0 128.0 154.0 105.0 163.0 79.5 127.0 123.0 147.0 101.0 159.0 76.5 117.0 117.0 138.0 97.0 153.0 73.2 110.0 110.0 128.0 92.2 145.0 69.6
85 142.0 142.0 154.0 123.0 164.0 95.9 135.0 135.0 147.0 120.0 159.0 94.2 127.0 127.0 138.0 116.0 153.0 91.7 120.0 120.0 128.0 111.0 146.0 88.5
90 150.0 150.0 155.0 142.0 166.0 112.0 144.0 144.0 148.0 139.0 161.0 111.0 137.0 137.0 139.0 136.0 154.0 109.0 130.0 130.0 130.0 130.0 146.0 107.0
75 139.0 114.0 155.0 89.8 163.0 60.4 129.0 109.0 149.0 85.4 159.0 57.9 120.0 104.0 141.0 89.5 154.0 55.0 109.0 98.9 131.0 85.1 147.0 51.6
5000 80 140.0 136.0 156.0 109.0 164.0 81.3 130.0 130.0 149.0 106.0 160.0 79.1 123.0 123.0 141.0 102.0 155.0 75.8 115.0 115.0 131.0 97.5 147.0 72.2
85 147.0 147.0 157.0 129.0 166.0 98.2 141.0 141.0 150.0 126.0 161.0 96.8 133.0 133.0 141.0 123.0 155.0 94.8 125.0 125.0 131.0 118.0 148.0 91.9
90 155.0 155.0 158.0 148.0 167.0 115.0 149.0 149.0 151.0 147.0 163.0 115.0 143.0 143.0 143.0 143.0 157.0 114.0 135.0 135.0 135.0 135.0 149.0 111.0
75 142.0 120.0 157.0 91.3 164.0 61.5 132.0 115.0 151.0 88.8 160.0 59.0 122.0 110.0 143.0 84.2 155.0 56.1 112.0 104.0 133.0 89.9 148.0 52.9
5500 80 143.0 143.0 158.0 112.0 165.0 82.0 135.0 135.0 152.0 110.0 161.0 80.4 127.0 127.0 143.0 107.0 156.0 78.3 119.0 119.0 134.0 102.0 149.0 74.7
85 152.0 152.0 159.0 133.0 167.0 99.9 145.0 145.0 152.0 132.0 163.0 99.1 138.0 138.0 144.0 129.0 157.0 97.4 130.0 130.0 134.0 125.0 150.0 95.0
90 159.0 159.0 160.0 154.0 169.0 118.0 153.0 153.0 153.0 153.0 164.0 118.0 147.0 147.0 147.0 147.0 158.0 117.0 140.0 140.0 140.0 140.0 151.0 116.0
75 145.0 125.0 158.0 93.3 165.0 62.5 135.0 120.0 153.0 91.2 161.0 60.1 125.0 115.0 145.0 87.3 156.0 57.2 115.0 110.0 136.0 82.8 149.0 54.0
6000 80 147.0 147.0 159.0 115.0 166.0 82.9 140.0 140.0 153.0 114.0 162.0 81.7 132.0 132.0 145.0 111.0 157.0 79.3 123.0 123.0 136.0 107.0 150.0 76.5
85 155.0 155.0 161.0 137.0 168.0 101.1 149.0 149.0 154.0 137.0 164.0 101.0 142.0 142.0 146.0 135.0 158.0 99.8 134.0 134.0 137.0 131.0 151.0 97.8
90 161.0 161.0 162.0 159.0 170.0 120.0 156.0 156.0 156.0 156.0 166.0 121.0 150.0 150.0 150.0 150.0 160.0 121.0 143.0 143.0 143.0 143.0 152.0 119.0
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Cooling Capacity
3. SHC = Sensible Heat Capacity
Table PD-2 — Gross Cooling Capacities (MBH) 15 Ton Three Phase TC*180B3, B4, BW, BK
Ambient Temperature
85 95 105 115
Enter.
Dry Entering Wet Bulb
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 168.0 133.0 188.0 106.0 198.0 73.0 157.0 128.0 181.0 101.0 194.0 70.4 147.0 122.0 172.0 97.0 187.0 67.3 137.0 117.0 162.0 92.1 179.0 63.2
5400 80 168.0 156.0 188.0 128.0 199.0 97.3 155.0 155.0 181.0 125.0 195.0 94.3 149.0 143.0 172.0 120.0 188.0 90.8 140.0 137.0 162.0 115.0 179.0 86.7
85 174.0 174.0 189.0 150.0 200.0 117.0 166.0 166.0 182.0 147.0 196.0 115.0 158.0 158.0 172.0 143.0 189.0 113.0 150.0 150.0 162.0 138.0 180.0 110.0
90 184.0 184.0 190.0 172.0 202.0 136.0 177.0 177.0 183.0 170.0 197.0 135.0 170.0 170.0 170.0 170.0 190.0 133.0 162.0 162.0 165.0 157.0 181.0 131.0
75 172.0 140.0 190.0 110.0 199.0 74.3 161.0 134.0 184.0 106.0 195.0 71.7 151.0 129.0 175.0 101.0 189.0 68.7 140.0 124.0 165.0 96.1 181.0 64.9
6000 80 169.0 169.0 191.0 133.0 200.0 99.4 164.0 157.0 184.0 130.0 196.0 97.2 155.0 151.0 176.0 126.0 190.0 93.8 145.0 145.0 165.0 121.0 182.0 89.9
85 181.0 181.0 192.0 156.0 202.0 119.0 173.0 173.0 185.0 154.0 198.0 118.0 165.0 165.0 176.0 151.0 191.0 116.0 157.0 157.0 166.0 146.0 183.0 113.0
90 189.0 189.0 193.0 179.0 204.0 140.0 183.0 183.0 183.0 183.0 199.0 139.0 176.0 176.0 178.0 171.0 193.0 138.0 168.0 168.0 170.0 166.0 184.0 136.0
75 176.0 147.0 192.0 112.0 200.0 75.5 165.0 141.0 186.0 110.0 196.0 73.0 154.0 136.0 178.0 105.0 190.0 69.8 144.0 130.0 168.0 99.8 182.0 66.1
6600 80 178.0 171.0 193.0 136.0 201.0 101.0 169.0 165.0 187.0 135.0 197.0 98.8 160.0 159.0 178.0 131.0 191.0 96.1 150.0 150.0 168.0 127.0 183.0 92.6
85 185.0 185.0 194.0 161.0 203.0 122.0 179.0 179.0 188.0 160.0 199.0 121.0 171.0 171.0 179.0 158.0 193.0 119.0 163.0 163.0 169.0 153.0 185.0 116.0
90 193.0 193.0 193.0 193.0 205.0 143.0 188.0 188.0 188.0 188.0 201.0 143.0 181.0 181.0 182.0 178.0 195.0 142.0 173.0 173.0 174.0 174.0 186.0 140.0
75 179.0 152.0 194.0 114.0 201.0 76.7 168.0 147.0 188.0 112.0 197.0 74.2 158.0 142.0 180.0 109.0 191.0 71.0 142.0 142.0 170.0 103.0 183.0 67.2
7200 80 182.0 177.0 195.0 140.0 202.0 103.0 173.0 172.0 189.0 139.0 198.0 100.0 164.0 164.0 181.0 136.0 192.0 97.6 155.0 155.0 171.0 132.0 184.0 94.4
85 189.0 189.0 196.0 166.0 204.0 125.0 183.0 183.0 190.0 166.0 200.0 123.0 176.0 176.0 182.0 164.0 194.0 121.0 167.0 167.0 167.0 167.0 186.0 119.0
90 197.0 197.0 197.0 197.0 206.0 146.0 192.0 192.0 193.0 187.0 202.0 146.0 185.0 185.0 186.0 184.0 196.0 146.0 177.0 177.0 177.0 177.0 188.0 144.0
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
RT-PRC002-EN 15
Performance (17½, 20 Ton)
Data Standard Efficiency
Table PD-3 — Gross Cooling Capacities (MBH) 17½ Ton Three Phase TC*210C3, C4, CW, CK
Ambient Temperature
85 95 105 115
Enter
Dry Entering Wet Bulb
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 195.0 171.0 213.0 127.0 224.0 83.3 182.0 164.0 206.0 124.0 219.0 80.1 169.0 158.0 195.0 119.0 213.0 76.1 155.0 151.0 181.0 113.0 204.0 71.8
6300 80 200.0 200.0 214.0 157.0 226.0 114.0 191.0 191.0 207.0 156.0 221.0 112.0 180.0 180.0 196.0 153.0 214.0 110.0 168.0 168.0 183.0 147.0 205.0 106.0
85 211.0 211.0 217.0 188.0 229.0 140.0 204.0 204.0 209.0 188.0 223.0 139.0 195.0 195.0 199.0 186.0 216.0 139.0 184.0 184.0 187.0 182.0 206.0 137.0
90 219.0 219.0 220.0 217.0 230.0 164.0 214.0 214.0 214.0 214.0 225.0 167.0 207.0 207.0 207.0 207.0 218.0 169.0 198.0 198.0 198.0 198.0 208.0 168.0
75 199.0 181.0 215.0 131.0 225.0 84.7 187.0 176.0 208.0 129.0 221.0 81.4 174.0 169.0 198.0 125.0 215.0 77.7 160.0 160.0 185.0 119.0 206.0 73.4
7000 80 206.0 206.0 217.0 164.0 228.0 116.0 198.0 198.0 210.0 164.0 222.0 114.0 188.0 188.0 200.0 162.0 216.0 113.0 176.0 176.0 187.0 157.0 207.0 110.0
85 216.0 216.0 220.0 197.0 230.0 144.0 210.0 210.0 213.0 198.0 225.0 144.0 202.0 202.0 204.0 198.0 218.0 145.0 192.0 192.0 192.0 192.0 209.0 144.0
90 224.0 224.0 224.0 224.0 233.0 172.0 219.0 219.0 219.0 219.0 227.0 173.0 212.0 212.0 212.0 212.0 221.0 177.0 204.0 204.0 204.0 204.0 211.0 177.0
75 203.0 191.0 217.0 135.0 226.0 86.1 192.0 187.0 211.0 138.0 222.0 82.9 178.0 178.0 201.0 131.0 216.0 79.2 165.0 165.0 188.0 126.0 208.0 75.0
7700 80 211.0 211.0 219.0 169.0 229.0 118.0 204.0 204.0 212.0 171.0 224.0 117.0 194.0 194.0 203.0 170.0 218.0 116.0 183.0 183.0 191.0 167.0 209.0 114.0
85 220.0 220.0 222.0 203.0 232.0 147.0 214.0 214.0 216.0 207.0 226.0 148.0 207.0 207.0 207.0 207.0 220.0 150.0 197.0 197.0 197.0 197.0 211.0 150.0
90 226.0 226.0 226.0 226.0 235.0 176.0 223.0 223.0 222.0 222.0 229.0 179.0 216.0 216.0 216.0 216.0 223.0 184.0 208.0 208.0 208.0 208.0 214.0 186.0
75 206.0 199.0 218.0 138.0 227.0 87.8 195.0 195.0 212.0 143.0 223.0 84.3 183.0 183.0 203.0 136.0 217.0 80.6 171.0 171.0 190.0 132.0 209.0 76.5
8400 80 214.0 214.0 221.0 174.0 230.0 120.0 208.0 208.0 214.0 178.0 226.0 120.0 199.0 199.0 205.0 178.0 219.0 119.0 188.0 188.0 194.0 176.0 211.0 117.0
85 222.0 222.0 224.0 210.0 233.0 150.0 217.0 217.0 218.0 215.0 228.0 151.0 211.0 211.0 211.0 211.0 222.0 155.0 202.0 202.0 202.0 202.0 213.0 156.0
90 229.0 229.0 229.0 229.0 236.0 181.0 225.0 225.0 225.0 225.0 231.0 184.0 220.0 220.0 219.0 219.0 225.0 190.0 212.0 212.0 212.0 212.0 216.0 193.0
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Cooling Capacity
3. SHC = Sensible Heat Capacity
Table PD-4 — Gross Cooling Capacities (MBH) 20 Ton Three Phase TC*240B3, B4, BW, BK
Ambient Temperature (F)
85 95 105 115
Enter.
Dry Entering Wet Bulb (F)
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 223.0 180.0 251.0 143.0 265.0 97.7 209.0 173.0 242.0 137.0 260.0 94.3 195.0 165.0 228.0 130.0 252.0 90.3 180.0 158.0 212.0 135.0 241.0 85.5
7200 80 226.0 214.0 252.0 173.0 267.0 131.0 208.0 208.0 242.0 169.0 261.0 127.0 197.0 197.0 228.0 162.0 253.0 122.0 186.0 186.0 213.0 155.0 242.0 117.0
85 235.0 235.0 253.0 204.0 268.0 158.0 224.0 224.0 242.0 200.0 262.0 156.0 213.0 213.0 229.0 194.0 253.0 153.0 201.0 201.0 214.0 188.0 242.0 149.0
90 248.0 248.0 255.0 234.0 271.0 185.0 239.0 239.0 245.0 232.0 264.0 185.0 228.0 228.0 228.0 228.0 255.0 183.0 217.0 217.0 217.0 217.0 243.0 179.0
75 229.0 190.0 255.0 148.0 267.0 99.4 215.0 183.0 246.0 142.0 262.0 96.1 200.0 175.0 233.0 136.0 254.0 92.2 185.0 168.0 218.0 129.0 244.0 87.1
8000 80 228.0 228.0 256.0 180.0 268.0 134.0 217.0 217.0 246.0 176.0 264.0 131.0 205.0 205.0 233.0 171.0 255.0 127.0 193.0 193.0 218.0 164.0 245.0 121.0
85 243.0 243.0 257.0 212.0 271.0 162.0 233.0 233.0 247.0 210.0 265.0 161.0 222.0 222.0 234.0 206.0 257.0 158.0 210.0 210.0 220.0 199.0 245.0 155.0
90 255.0 255.0 259.0 245.0 273.0 190.0 247.0 247.0 247.0 247.0 267.0 191.0 237.0 237.0 237.0 237.0 258.0 190.0 226.0 226.0 226.0 226.0 247.0 187.0
75 234.0 199.0 257.0 151.0 268.0 101.0 220.0 192.0 249.0 147.0 263.0 97.9 205.0 184.0 237.0 141.0 256.0 93.7 190.0 177.0 222.0 134.0 246.0 88.6
8800 80 236.0 236.0 259.0 185.0 270.0 136.0 224.0 224.0 249.0 183.0 265.0 134.0 212.0 212.0 237.0 178.0 257.0 130.0 200.0 200.0 222.0 172.0 247.0 126.0
85 250.0 250.0 260.0 220.0 273.0 165.0 240.0 240.0 251.0 219.0 267.0 165.0 229.0 229.0 239.0 216.0 259.0 163.0 217.0 217.0 225.0 210.0 248.0 160.0
90 260.0 260.0 263.0 254.0 275.0 194.0 253.0 253.0 253.0 253.0 270.0 196.0 244.0 244.0 244.0 244.0 261.0 196.0 233.0 233.0 233.0 233.0 250.0 194.0
75 238.0 208.0 259.0 154.0 269.0 103.0 224.0 201.0 251.0 151.0 265.0 99.6 209.0 193.0 240.0 146.0 257.0 95.1 194.0 186.0 225.0 139.0 248.0 89.2
9600 80 242.0 242.0 261.0 190.0 271.0 137.0 231.0 231.0 252.0 189.0 266.0 136.0 219.0 219.0 240.0 185.0 259.0 133.0 206.0 206.0 226.0 180.0 249.0 129.0
85 254.0 254.0 263.0 227.0 274.0 167.0 246.0 246.0 254.0 227.0 269.0 168.0 236.0 236.0 243.0 225.0 261.0 167.0 224.0 224.0 229.0 220.0 251.0 165.0
90 264.0 264.0 264.0 264.0 277.0 198.0 258.0 258.0 258.0 258.0 272.0 201.0 249.0 249.0 249.0 249.0 263.0 202.0 239.0 239.0 239.0 239.0 252.0 201.0
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
16 RT-PRC002-EN
Performance (25 Ton)
Data Standard Efficiency
Table PD-5— Gross Cooling Capacities (MBH) 25 Ton Three Phase TC*300B3, B4, BW, BK
Ambient Temperature (F)
85 95 105 115
Enter.
Dry Entering Wet Bulb (F)
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 266 224 299 174 319 118 247 215 285 167 309 113 228 205 266 172 297 108 209 196 244 163 280 99.9
80 270 268 300 215 321 161 252 252 285 209 311 155 237 237 266 200 297 149 221 221 244 190 280 142
9000 85 286 286 301 255 323 196 272 272 286 250 312 194 256 256 267 242 298 189 240 240 246 233 281 183
90 301 301 304 295 326 232 289 289 289 289 314 231 275 275 275 275 300 229 259 259 259 259 282 224
75 272 237 303 180 322 120 253 227 290 174 312 115 234 218 271 165 300 109 214 208 249 156 284 102
80 277 277 304 223 324 171 262 262 290 219 314 161 246 246 271 211 301 155 229 229 249 201 284 147
10000 85 294 294 306 266 327 208 282 282 291 263 316 200 266 266 273 257 302 197 249 249 253 248 285 192
90 308 308 310 309 329 239 297 297 297 297 318 240 284 284 284 284 304 239 268 268 268 268 286 235
75 275 243 305 183 323 122 256 233 291 177 314 117 236 223 273 188 301 111 216 214 251 178 285 103
80 282 282 306 227 325 174 267 267 292 223 315 162 250 250 273 216 302 157 233 233 251 206 286 150
10500 85 298 298 308 272 328 216 286 286 294 270 317 203 270 270 276 264 304 200 253 253 256 255 286 196
90 312 312 311 311 330 256 301 301 301 301 320 244 288 288 288 288 306 244 273 273 272 272 288 241
75 278 248 306 185 324 123 258 239 293 181 315 118 239 229 275 172 302 113 217 217 253 184 286 104
80 286 286 308 231 325 160 271 271 294 228 316 163 254 254 276 221 304 160 237 237 253 212 287 153
11000 85 301 301 310 277 327 224 289 289 296 276 319 205 274 274 278 271 305 204 257 257 257 257 288 200
90 314 314 314 314 330 266 304 304 304 304 321 248 291 291 291 291 307 249 276 276 276 276 289 246
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
4. Table is for 460 volt capacity. For capacity at 230 volt, multiply table capacity by 101%.
RT-PRC002-EN 17
Performance (12½ Ton)
Data High Efficiency
Table PD-6 — Gross Cooling Capacities (MBH) 12½ Ton Three Phase TC*151C3, C4, CW
Ambient Temperature
85 95 105 115
Enter
Dry Entering Wet Bulb
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 137.0 116.0 157.0 90.2 166.0 60.8 127.0 110.0 151.0 87.1 163.0 58.5 116.0 105.0 140.0 82.3 158.0 55.8 106.0 99.7 128.0 80.6 152.0 52.8
4500 80 140.0 139.0 158.0 111.0 167.0 82.9 130.0 130.0 151.0 109.0 164.0 80.8 122.0 122.0 141.0 104.0 159.0 77.8 114.0 114.0 128.0 98.5 152.0 74.6
85 149.0 149.0 158.0 132.0 169.0 100.0 142.0 142.0 151.0 131.0 165.0 99.4 133.0 133.0 141.0 126.0 159.0 98.2 125.0 125.0 130.0 121.0 152.0 96.0
90 158.0 158.0 160.0 153.0 170.0 118.0 152.0 152.0 154.0 152.0 166.0 118.0 145.0 145.0 145.0 145.0 160.0 118.0 137.0 137.0 137.0 137.0 153.0 117.0
75 141.0 123.0 159.0 93.4 167.0 61.6 131.0 117.0 154.0 90.9 164.0 59.4 120.0 112.0 144.0 86.6 159.0 56.8 109.0 107.0 132.0 81.0 153.0 53.7
5000 80 145.0 145.0 160.0 116.0 168.0 84.1 136.0 136.0 154.0 114.0 165.0 82.4 128.0 128.0 144.0 110.0 161.0 80.9 119.0 119.0 132.0 105.0 154.0 77.5
85 155.0 155.0 161.0 138.0 170.0 103.0 148.0 148.0 155.0 138.0 166.0 102.0 140.0 140.0 145.0 135.0 161.0 102.0 131.0 131.0 134.0 129.0 154.0 100.0
90 162.0 162.0 163.0 160.0 172.0 121.0 157.0 157.0 157.0 157.0 168.0 122.0 151.0 151.0 151.0 151.0 163.0 123.0 143.0 143.0 143.0 143.0 155.0 122.0
75 145.0 129.0 161.0 95.8 168.0 62.6 134.0 124.0 156.0 94.4 165.0 60.4 123.0 119.0 147.0 90.4 161.0 57.8 112.0 112.0 135.0 85.1 154.0 54.6
5500 80 150.0 150.0 162.0 119.0 169.0 85.2 142.0 142.0 156.0 119.0 167.0 84.0 133.0 133.0 147.0 116.0 162.0 82.4 124.0 124.0 135.0 111.0 155.0 80.1
85 158.0 158.0 163.0 143.0 172.0 104.0 153.0 153.0 157.0 144.0 168.0 104.0 146.0 146.0 149.0 143.0 163.0 105.0 137.0 137.0 137.0 137.0 156.0 104.0
90 165.0 165.0 165.0 165.0 173.0 123.0 161.0 161.0 161.0 161.0 170.0 126.0 156.0 156.0 156.0 156.0 164.0 127.0 149.0 149.0 149.0 149.0 157.0 127.0
75 148.0 136.0 162.0 97.9 168.0 63.5 137.0 131.0 157.0 97.1 166.0 61.4 126.0 125.0 150.0 94.3 162.0 58.9 116.0 116.0 138.0 89.0 155.0 55.6
6000 80 154.0 154.0 163.0 123.0 170.0 86.2 147.0 147.0 158.0 124.0 168.0 85.8 138.0 138.0 150.0 122.0 162.0 83.3 128.0 128.0 138.0 117.0 156.0 82.2
85 161.0 161.0 165.0 147.0 172.0 106.0 157.0 157.0 160.0 150.0 169.0 106.0 151.0 151.0 152.0 150.0 164.0 107.0 142.0 142.0 142.0 142.0 158.0 107.0
90 167.0 167.0 167.0 167.0 174.0 126.0 164.0 164.0 164.0 164.0 171.0 128.0 159.0 159.0 159.0 159.0 166.0 131.0 153.0 153.0 153.0 153.0 159.0 132.0
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Cooling Capacity
3. SHC = Sensible Heat Capacity
18 RT-PRC002-EN
Performance (15, 17½ Ton)
Data High Efficiency
Table PD-7 — Gross Cooling Capacities (MBH) 15 Ton Three Phase TC*181C3, C4, CW
Ambient Temperature
85 95 105 115
Enter.
Dry Entering Wet Bulb
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 172 144 194 112 205 75.2 159 138 185 107 200 71.9 147 131 172 101 193 68 130 130 158 97 183 63.4
5400 80 175 169 195 138 207 103 164 162 186 134 202 99.7 153 153 173 128 194 95.4 142 142 158 122 183 90.5
85 185 185 196 164 209 126 176 176 186 161 203 124 165 165 174 156 195 122 155 155 155 155 184 117
90 195 195 195 195 211 149 188 188 190 184 204 148 178 178 179 179 196 147 168 168 167 167 184 144
75 177 153 197 116 207 76 164 147 189 112 202 73.2 151 140 176 106 195 69.3 138 131 162 99.8 185 64.8
6000 80 181 180 198 144 209 105 170 170 189 142 204 103 159 159 177 136 196 99.4 148 148 162 130 186 94.6
85 192 192 199 172 211 129 183 183 190 171 206 129 173 173 173 173 197 127 162 162 162 162 186 124
90 201 201 200 200 214 153 194 194 195 194 208 155 185 185 185 185 199 154 175 175 175 175 187 152
75 181 162 198 123 208 76.6 168 155 191 117 204 74.4 152 152 180 111 197 70.6 142 139 165 105 187 66.2
6600 80 186 186 200 151 210 107 177 177 192 148 206 105 166 166 180 144 198 102 154 154 166 137 188 98.6
85 197 197 202 179 213 131 189 189 194 180 208 132 179 179 183 173 199 132 168 168 170 166 189 129
90 204 204 205 202 215 157 199 199 199 199 209 159 191 191 191 191 201 160 181 181 181 181 190 160
75 184 170 200 127 209 79.1 168 168 193 121 206 76.4 156 156 182 116 198 71.9 145 145 168 110 189 67.4
7200 80 191 191 202 153 211 108 182 182 194 154 207 107 171 171 183 151 199 105 159 159 169 145 190 102
85 200 200 204 185 214 134 194 194 194 194 209 136 185 185 187 181 201 135 174 174 174 174 191 134
90 207 207 208 207 217 160 203 203 203 203 211 163 195 195 195 195 203 166 186 186 186 186 192 167
NOTES:
1 All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
Table PD-8 — Gross Cooling Capacities (MBH)17½ Ton Three Phase TC*211C3, C4, CW
Ambient Temperature
85 95 105 115
Enter
Dry Entering Wet Bulb
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 200.0 169.0 224.0 130.0 233.0 86.2 184.0 162.0 215.0 125.0 231.0 83.3 169.0 154.0 199.0 118.0 226.0 79.3 147.0 147.0 180.0 113.0 214.0 74.2
6300 80 202.0 202.0 225.0 161.0 236.0 118.0 190.0 190.0 216.0 158.0 234.0 117.0 177.0 177.0 200.0 151.0 227.0 112.0 164.0 164.0 181.0 142.0 214.0 107.0
85 216.0 216.0 227.0 191.0 239.0 143.0 206.0 206.0 217.0 190.0 236.0 146.0 193.0 193.0 202.0 184.0 228.0 144.0 180.0 180.0 185.0 176.0 215.0 139.0
90 227.0 227.0 230.0 221.0 242.0 169.0 220.0 220.0 220.0 220.0 239.0 175.0 209.0 209.0 209.0 209.0 229.0 174.0 196.0 196.0 195.0 195.0 217.0 171.0
75 205.0 180.0 226.0 134.0 234.0 87.6 190.0 172.0 219.0 131.0 233.0 84.8 174.0 164.0 204.0 124.0 228.0 80.8 155.0 155.0 184.0 116.0 218.0 76.0
7000 80 210.0 210.0 228.0 167.0 237.0 119.0 198.0 198.0 220.0 167.0 236.0 120.0 185.0 185.0 205.0 160.0 229.0 117.0 171.0 171.0 186.0 152.0 218.0 112.0
85 223.0 223.0 230.0 199.0 241.0 145.0 215.0 215.0 222.0 202.0 238.0 150.0 202.0 202.0 209.0 197.0 231.0 150.0 188.0 188.0 191.0 189.0 219.0 147.0
90 232.0 232.0 233.0 230.0 244.0 173.0 227.0 227.0 227.0 227.0 241.0 180.0 218.0 218.0 218.0 218.0 232.0 182.0 205.0 205.0 204.0 204.0 221.0 181.0
75 210.0 190.0 228.0 138.0 235.0 88.9 195.0 183.0 222.0 137.0 234.0 86.0 179.0 175.0 208.0 130.0 229.0 82.4 161.0 161.0 188.0 122.0 220.0 77.7
7700 80 217.0 217.0 231.0 173.0 239.0 120.0 206.0 206.0 223.0 174.0 237.0 121.0 192.0 192.0 209.0 169.0 231.0 121.0 178.0 178.0 190.0 161.0 221.0 116.0
85 228.0 228.0 232.0 206.0 242.0 148.0 221.0 221.0 226.0 211.0 240.0 153.0 210.0 210.0 214.0 209.0 234.0 156.0 196.0 196.0 195.0 195.0 222.0 154.0
90 235.0 235.0 235.0 235.0 245.0 176.0 232.0 232.0 232.0 232.0 243.0 185.0 224.0 224.0 224.0 224.0 235.0 189.0 213.0 213.0 212.0 212.0 224.0 191.0
75 214.0 200.0 230.0 141.0 236.0 90.3 200.0 193.0 224.0 141.0 235.0 87.4 181.0 181.0 211.0 136.0 230.0 83.8 166.0 166.0 191.0 128.0 222.0 79.2
8400 80 222.0 222.0 232.0 177.0 239.0 133.0 213.0 213.0 226.0 181.0 238.0 123.0 199.0 199.0 213.0 178.0 233.0 124.0 184.0 184.0 194.0 170.0 223.0 121.0
85 231.0 231.0 234.0 211.0 243.0 149.0 226.0 226.0 229.0 220.0 241.0 155.0 216.0 216.0 216.0 216.0 235.0 161.0 203.0 203.0 202.0 202.0 224.0 162.0
90 238.0 238.0 238.0 238.0 246.0 178.0 235.0 235.0 235.0 235.0 244.0 189.0 229.0 229.0 229.0 229.0 237.0 195.0 219.0 219.0 219.0 219.0 227.0 199.0
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Cooling Capacity
3. SHC = Sensible Heat Capacity
RT-PRC002-EN 19
Performance (20, 25 Ton)
Data High Efficiency
Table PD-9 — Gross Cooling Capacities (MBH) 20 Ton Three Phase TC*241C3, C4, CW
Ambient Temperature (F)
85 95 105 115
Enter.
Dry Entering Wet Bulb (F)
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 246 205 273 158 284 105 228 196 263 152 280 101 208 186 246 145 273 96.5 191 176 222 136 261 91.5
7200 80 250 245 274 192 287 142 232 232 264 190 283 141 216 216 246 183 274 135 201 201 223 172 261 130
85 263 263 275 227 290 171 251 251 265 228 285 173 236 236 248 221 275 170 219 219 225 211 262 168
90 274 274 278 262 293 201 266 266 268 265 288 206 254 254 254 254 277 205 239 239 237 237 262 205
75 253 218 275 163 285 107 234 209 267 159 282 103 214 199 252 152 275 98.3 194 189 228 142 266 93.6
8000 80 257 257 277 199 289 144 243 243 268 199 285 143 227 227 252 194 277 140 210 210 228 184 266 136
85 270 270 279 236 292 174 261 261 270 240 288 177 247 247 255 237 278 177 230 230 232 226 266 177
90 280 280 282 273 295 205 274 274 274 274 291 212 264 264 264 264 280 214 250 250 248 248 267 218
75 258 230 278 167 287 109 240 221 270 164 284 105 219 211 256 159 277 100 199 199 232 149 269 95.5
8800 80 264 264 280 204 290 155 252 252 271 208 287 145 236 236 257 205 279 144 218 218 233 195 269 141
85 276 276 282 244 293 177 268 268 274 250 290 181 256 256 260 251 281 182 240 240 238 238 269 185
90 285 285 286 281 297 209 280 280 280 280 293 217 271 271 271 271 283 221 258 258 258 258 271 229
75 262 240 280 169 288 110 246 233 273 169 285 106 225 223 260 166 278 102 205 205 236 156 271 97.1
9600 80 270 270 282 209 291 161 260 260 274 215 288 147 245 245 261 215 281 147 226 226 237 205 271 146
85 280 280 284 250 295 179 274 274 277 260 291 184 263 263 265 263 282 186 248 248 246 246 272 193
90 288 288 288 288 298 212 284 284 284 284 294 222 276 276 276 276 285 228 264 264 265 265 275 240
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
Table PD-10 — Gross Cooling Capacities (MBH)25 Ton Three PhaseTC*301C3, C4, CW
Ambient Temperature (F)
85 95 105 115
Enter.
Dry Entering Wet Bulb (F)
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73
Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 277 243 306 187 316 117 258 234 295 178 314 115 238 224 276 169 305 110 218 214 253 163 292 104
9000 80 284 284 307 225 321 169 269 269 295 225 317 161 252 252 277 217 307 158 235 235 254 207 293 151
85 300 300 309 269 325 198 289 289 298 271 320 202 273 273 280 266 308 201 256 256 259 256 293 198
90 312 312 313 312 329 236 305 305 305 305 321 240 293 293 293 293 310 245 277 277 277 277 295 244
75 284 258 310 188 319 121 264 249 299 185 316 117 244 239 282 178 308 112 224 224 259 168 295 106
10000 80 294 294 310 233 323 175 280 280 300 236 319 170 263 263 283 230 309 163 245 245 260 221 296 158
85 307 307 313 280 327 202 298 298 303 286 322 207 284 284 287 284 312 208 267 267 267 267 297 208
90 318 318 318 318 331 241 312 312 312 312 324 248 301 301 301 301 314 255 287 287 287 287 299 257
75 286 265 311 190 320 122 267 256 300 189 316 118 247 246 284 182 309 113 228 228 261 172 296 107
10500 80 297 297 312 237 324 178 285 285 302 241 320 174 267 267 285 237 310 165 249 249 262 227 298 162
85 310 310 315 285 328 204 302 302 305 293 323 210 289 289 289 289 313 212 272 272 272 272 299 213
90 320 320 320 320 332 244 314 314 314 314 325 251 305 305 305 305 316 260 292 292 292 292 301 264
75 289 272 312 192 321 123 270 264 302 192 317 119 249 249 286 186 309 114 231 231 263 176 297 108
11000 80 300 300 313 240 324 181 289 289 304 246 321 177 272 272 287 243 311 170 253 253 265 234 299 165
85 312 312 316 289 329 205 305 305 307 299 324 212 293 293 293 293 314 215 276 276 276 276 300 217
90 322 322 321 321 332 246 317 317 317 317 326 255 308 308 308 308 317 265 295 295 295 295 303 270
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
20 RT-PRC002-EN
Performance (12½ Ton)
Data Standard Efficiency
RT-PRC002-EN 21
Performance (15Ton)
Data Standard Efficiency
5 HP Oversized Motor & Sheaves 5 HP OS Motor & Field Supplied Drive (3)
For Standard Evaporator Fan Speed (RPM), reference Table PD-22. Trane’s factory supplied motors, in commercial equipment, are
For Standard Motor & High Static Drive Accessory Fan Speed (RPM), reference Table PD-23. definite purpose motors, specifically designed and tested to
For Oversized Evaporator Fan Speed (RPM), reference Table PD-24. operate reliably and continuously at all cataloged conditions.
Using the full horsepower range of our fan motors as shown in our
NOTES:
tabular data will not result in nuisance tripping or premature motor
Fan motor heat (MBH) = 3.15 x Fan BHP
failure. Our product’s warranty will not be affected.
Data includes pressure drop due to wet coils and filters
No accessories or options are included in pressure drop data.
Refer to Table PD-26 to determine add’l static pressure drop
due to other options/accessories.
1. Field Supplied Fan Sheave BK105 Required. Field Supplied Belt
may be necessary.
2. 5 HP Oversized Motor with Field Supplied Fan Sheave BK160
Required.
Field Supplied Belt may be necessary.
3. 5 HP Oversized Motor with Field Supplied Motor Sheave IVP50
Required. Field Supplied Belt may be necessary.
4. For 380V/60 Hz units, the oversized motor is used as the standard
motor. Refer to “Motor & Sheave/Fan Speed” tables to determine
operating range.
22 RT-PRC002-EN
Performance (17½Ton)
Data Standard Efficiency
For Standard Evaporator Fan Speed (RPM), reference Table PD-22. 7.5 HP Oversive Motor & Sheaves
For Standard Motor & Low Static Drive Accessory Fan Speed (RPM), reference Table PD-25.
For Oversized Evaporator Fan Speed (RPM), reference Table PD-24.
NOTE: Trane’s factory supplied motors, in commercial equipment, are
Fan motor heat (MBH) = 3.15 x Fan BHP definite purpose motors, specifically designed and tested to operate
Data includes pressure drop due to wet coils and filters reliably and continuously at all cataloged conditions. Using the full
No accessories or options are included in pressure drop data. horsepower range of our fan motors as shown in our tabular data will
Refer to Table PD-26 to determine add’l static pressure drop not result in nuisance tripping or premature motor failure. Our
due to other options/accessories. product’s warranty will not be affected.
1. For 380V/60 Hz units, the oversized motor is used as the standard motor. Refer to “Motor &
Sheave/Fan Speed” tables to determine operating range.
RT-PRC002-EN 23
Performance (20 Ton)
Data Standard Efficiency
24 RT-PRC002-EN
Performance (25 Ton)
Data Standard Efficiency
7.5 HP Standard Motor & Sheaves 7.5 HP Standard Motor & High Static Drive Accessory
RT-PRC002-EN 25
Performance (12½ Ton)
Data High Efficiency
26 RT-PRC002-EN
Performance (12½ Ton)
Data High Efficiency
RT-PRC002-EN 27
Performance (15 Ton)
Data High Efficiency
28 RT-PRC002-EN
Performance (17½ Ton)
Data High Efficiency
RT-PRC002-EN 29
Performance (20 Ton)
Data High Efficiency
For Standard Evaporator Fan Speed (RPM), reference Table PD-22. Trane’s factory supplied motors, in commercial equipment, are
For Standard Motor & High Static Drive Accessory Fan Speed (RPM), reference Table PD-23. definite purpose motors, specifically designed and tested to operate
For Oversized Evaporator Fan Speed (RPM), reference Table PD-24. reliably and continuously at all cataloged conditions. Using the full
horsepower range of our fan motors as shown in our tabular data
NOTES:
will not result in nuisance tripping or premature motor failure. Our
Fan motor heat (MBH) = 3.15 x Fan BHP
product’s warranty will not be affected.
Data includes pressure drop due to wet coils and filters
No accessories or options are included in pressure drop data.
1. Field Supplied Fan Sheave BK190 Required. Field Supplied Belt may
be necessary.
2. 7.5 HP Standard Motor with Field Supplied Motor Sheave 1VP50
Required. Field Supplied Belt may be necessary.
30 RT-PRC002-EN
Performance (25 Ton)
Data High Efficiency
NOTE:
Fan motor heat (MBH) = 3.15 x Fan BHP
Data includes pressure drop due to wet coils and filters
No accessories or options are included in pressure drop data.
Refer to Table PD-26 to determine add’l static pressure drop
due to other options/accessories.
RT-PRC002-EN 31
Performance (12½-25 Ton)
Data
Table PD-23— Standard Motor & High Static Drive Accessory/Fan Speed (Rpm)
Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn
Tons Model No. Open Open Open Open Open Open Closed
12½ TC*151C3,4,W 807 857 908 958 1009 1059 NA
TC*180B3,4,W 806 849 891 934 976 1019 NA
15
TC*181B3,4,W 640 680 720 760 800 840 NA
17½ TC*211C3,4,W 835 879 923 967 1011 1055 NA
20 TC*240B/241C3,4,W 835 879 923 967 1011 1055 NA
25 TC*300B/301C3,4,W 816 853 890 928 965 1002 NA
32 RT-PRC002-EN
Performance (12½-25 Ton)
Data
Table PD-26 — Static Pressure Drops Through Accessories (Inches Water Column)
Economizer with Electric Heater
Unit Standard 2 Inch OA/RA Dampers2 Accessory (KW)3
Tons Model No. CFM Filters1 Pleated Filters4 100% OA 100% RA 5-12 14-23 36 54 72
TC*150D 4000 .05 .08 .19 .02 — .03 .03 .04 —
12½ TC*151C 5000 .07 .11 .26 .03 — .04 .05 .06 —
6000 .10 .15 .33 .04 — .06 .07 .09 —
4800 .07 .10 .25 .03 — .04 .04 .05 —
TC*180B 6000 .10 .15 .33 .04 — .06 .07 .08 —
7200 .15 .19 .40 .05 — .09 .10 .12 —
15 4800 .04/.03 .07/.06 .14 .03 — 04 .04 .05 —
TCD/TCH181C 6000 .06/.05 .10/.09 .20 .04 — 06 .07 .08 —
7200 .09/.07 .13/.11 .27 .05 — 09 .10 .12 —
5600 .09 .13 .30 .04 — — .06 .07 —
TC*210C 7000 .14 .18 .39 .05 — — .10 .11 —
8400 .20 .24 .47 .06 — — .15 .17 —
17½ 5600 .06/.05 .09/.08 .18 .04 — — .05 .06 .07
TCD/TCH211C 7000 .09/.07 .13/.11 .26 .04 — — .08 .09 .11
8400 .12/.10 .17/.14 .35 .06 — — .12 .13 .16
6400 .07 .11 .22 .04 — — .06 .08 .09
TCD240B 8000 .11 .15 .32 .05 — — .10 .12 .14
TCD241C 9600 .16 .20 .44 .07 — — .14 .17 .20
20 6400 .06 .10 .22 .04 — — .06 .08 .09
TCH240B 8000 .09 .13 .32 .05 — — .10 .12 .14
TCH241C 9600 .13 .17 .44 .07 — — .14 .17 .20
7000 .09 .13 .26 .04 — — .08 .10 .11
TCD300B 9000 .14 .18 .40 .07 — — .13 .15 .18
TCD301C 11000 .21 .25 .57 .10 — — .18 .22 .26
25 7000 .07 .11 .26 .04 — — .08 .10 .11
TCH300B 9000 .11 .15 .40 .07 — — .13 .15 .18
TCH301C 11000 .17 .22 .60 .10 — — .18 .22 .26
NOTES:
1. Tested with: 2” filters 12½-25 tons
2. OA = Outside Air and RA = Return Air.
3. Nominal KW ratings at 240, 480, 600 volts.
4. Difference in pressure drop should be considered when utilizing optional 2” pleated filters.
RT-PRC002-EN 33
Performance (12½-25 Ton)
Data
4. 27KW heater can be used with TCD181C4, TCD211C4, TCD241C4 andTCD301C4 only. Cannot be used with oversized motor.
For minimum design airflow, see airflow performance table for each unit.
To calculate temp rise at different air flow, use following formula:
KW x 3413
Temp. Rise across Elect. Htr =
1.08 x CFM
NOTES:
1. Not available on TC*210 model.
2. 27KW heater can be used with TCD181C4, TCD211C4, TCD241C4 andTCD301C4 only. Cannot be used with oversized motor.
34 RT-PRC002-EN
Controls
Field Installed Control Options Digital Display Zone Sensor CO2 Sensing —The CO2 sensor has the
The Digital LCD (Liquid Crystal Display) ability to monitor space occupancy levels
Zone Sensors zone sensor has the look and functionality within the
Zone sensors are the building occupant’s of standard zone building by
comfort control devices.They replace the sensors.This measuring the
conventional electro-mechanical sensor includes a parts per million
thermostats.The following zone sensor digital display of of CO2 (Carbon
options are available for Voyager units set point Dioxide) in the air.
with the ReliaTel™ control: adjustment and As the CO2 levels
Manual Changeover space temperature increase, the
Heat, Cool or Off in F (Fahrenheit) or outside air
System Switch. Fan C (Celsius). damper
Auto or Off Switch. Includes FAN and modulates to
One temperature SYSTEM buttons meet the CO2 space ventilation
setpoint lever. (supports the requirements.The CO2 sensor kit is
service functions of available as a field installed accessory.
the standard Economizer Controls
sensor). E-squared memory stores last The standard equipment offering is a
programmed set points. Requires 24 VAC fixed dry bulb changeover control. In
(Volts AC).This sensor should be utilized addition, there are two optional controls,
Manual/Automatic Changeover with ReliaTel controls.
Auto, Heat, Cool or Off System Switch. Enthalpy and Differential Enthalpy
Fan Auto or Off Control.
Programmable Night Setback
Switch.Two Enthalpy Control
Auto or manual changeover with seven-
temperature Replaces the dry bulb control with a wet
day programming. Keyboard selection
setpoint levers. bulb changeover controller which has a
Optional Status fully adjustable set point. Enthalpy control
Indication LED lights, offers a higher level of comfort control,
System On, Heat, along with energy savings potential, than
Cool, or Service. the standard dry bulb control. This is due
to the additional wet bulb sensing
capability.
Differential Enthalpy
Replaces the standard dry bulb control
Remote Sensor with two enthalpy sensors that compare
Sensor(s) available total heat content of the indoor air and
for all zone sensors to of Heat, Cool, Fan, Auto, or On. All outdoor air to determine the most
provide remote programmable sensors have System On, efficient air source.This control option
sensing capabilities. Heat, Cool, Service LED/indicators as offers the highest level of comfort control,
standard. Night Setback Sensors have plus energy efficiency, available.
one (1) Occupied, one (1) Un-occupied, Remote Potentiometer
and two (2) Override programs per day. Minimum position setting of economizer
can be remotely adjusted with this
accessory.
Integrated
ComfortTM Differential Pressure Switches
System This factory or field-installed option
Dual Thermistor Remote Zone Sensor Sensor(s) allows individual fan failure and dirty filter
This sensor will allow the customer to available with indication. The fan failure switch will
reduce the total number of remote optional disable all unit functions and “flash” the
sensors to obtain space temperature temperature Service LED on the zone sensor. The dirty
averaging. This sensor should be utilized adjustment and filter switch will light the Service LED on
with ReliaTel controls. override buttons the zone sensor and will allow continued
to provide central unit operation.
control through a Trane Communication Interface (TCI)
Trane Integrated This factory or field-installed micro-
Comfort system. processor interface allows the unit to
communicate toTrane’s Integrated
Comfort system.
RT-PRC002-EN 35
Electrical (Standard
Data Efficiency)
NOTE:
1. HACR breaker per NEC.
2. Values do not include power exhaust accessory.
36 RT-PRC002-EN
Electrical
Data (High Efficiency)
NOTE:
1. HACR breaker per NEC.
2. Values do not include power exhaust accessory.
Table ED-3— Unit Wiring — TXV/Face-Split Evaporator Coil Option (Downflow Only) — High Efficiency
Standard Indoor Fan Motor Oversize Indoor Fan Motor
Unit Minimum Maximum Fuse Minimum Maximum Fuse
Unit Operating Circuit Size Or Maximum Circuit Size Or Maximum
Tons Model No. Voltage Range Ampacity2 Circuit Breaker1 Ampacity2 Circuit Breaker1
TCD151C3 187-253 59 70 65 80
12½ TCD151C4 414-506 30 35 32 40
TCD151CW 517-633 24 30 26 30
TCD181C3 187-253 74 90 80 90
15 TCD181C4 414-506 37 50 39 50
TCD181CW 517-633 30 40 32 40
TCD211C3 187-253 91 125 99 125
17½ TCD211C4 414-506 45 60 49 60
TCD211CW 517-633 36 45 39 50
TCD241C3 187-253 99 125 107 125
20 TCD241C4 414-506 51 60 54 70
TCD241CW 517-633 40 50 43 50
TCD301C3 187-253 117 150 N/A N/A
25 TCD301C4 414-506 57 70 N/A N/A
TCD301CW 517-633 46 50 N/A N/A
NOTE:
1. HACR breaker per NEC.
2. Values do not include power exhaust accessory.
RT-PRC002-EN 37
Electrical
Data
NOTES:
1. 12½ Ton Standard Unit.
2. 12½ Ton High Efficiency Unit.
38 RT-PRC002-EN
Electrical
Data
Table ED-5 — Unit Wiring With Electric Heat (Single Point Connection) — Standard Efficiency
RT-PRC002-EN 39
Electrical
Data
Table ED-5 — Unit Wiring With Electric Heat (Single Point Connection) — Standard Efficiency continued
40 RT-PRC002-EN
Electrical
Data
Table ED-6 — Unit Wiring With Electric Heat (Single Point Connection) — Standard Efficiency
RT-PRC002-EN 41
Electrical
Data
Table ED-6 — Unit Wiring With Electric Heat (Single Point Connection) — Standard Efficiency continued
42 RT-PRC002-EN
Electrical
Data
Table ED-7 — Unit Wiring With Electric Heat (Single Point Connection) — High Efficiency
Standard Indoor Motor Oversize Indoor Motor
To Use Heater Heater Control Max Fuse Size or Max Fuse Size or
Tons With Model No. KW Rating Stages MCA Max Circuit Breaker1 MCA Max Circuit Breaker2
208/230 Volts Three Phase
AYDHTRK318A 13.5/18.0 1 64/68 80/80 70/76 90/90
12½ TCD151C3 AYDHTRK336A 27.0/36.0 2 108/122 110/125 115/130 125/150
AYDHTRK354A 40.5/54.0 2 154/176 175/200 162/184 175/200
AYDHTRK318A 13.5/18.0 1 74/74 100/100 80/80 100/100
15 TCD181C3 AYDHTRK336A 27.0/36.0 2 108/122 110/125 115/130 125/150
AYDHTRK354A 40.5/54.0 2 154/176 175/200 162/184 175/200
AYDHTRL336A 27.0/36.0 2 115/130 125/150 125/139 125/150
17½ TCD211C3 AYDHTRL354A 40.5/54.0 2 162/184 175/200 171/193 175/200
AYDHTRK372A 54.0/72.0 2 209/238 225/250 218/247 225/250
AYDHTRL336A 27.0/36.0 2 115/130 125/150 125/139 125/150
20 TCD241C3 AYDHTRL354A 40.5/54.0 2 162/184 175/200 171/193 175/200
AYDHTRK372A 54.0/72.0 2 209/238 225/250 218/247 225/250
AYDHTRL336A 27.0/36.0 2 125/139 150/150 — —
25 TCD301C3 AYDHTRL354A 40.5/54.0 2 171/193 175/200 — —
AYDHTRK372A 54.0/72.0 2 218/247 225/250 — —
RT-PRC002-EN 43
Electrical
Data
Table ED-8 — Unit Wiring With Electric Heat (Single Point Connection) — High Efficiency
Standard Indoor Motor Oversize Indoor Motor
To Use Heater Heater Control Max Fuse Size or Max Fuse Size or
Tons With Model No. KW Rating Stages MCA Max Circuit Breaker1 MCA Max Circuit Breaker2
208/230 Volts Three Phase
AYHHTRN318A 13.5/18.0 1 64/68 80/80 70/76 90/90
12½ TCH151C3 AYHHTRP336A 27.0/36.0 2 108/122 110/125 115/130 125/150
AYHHTRP354A 40.5/54.0 2 154/176 175/200 162/184 175/200
AYHHTRM318A 13.5/18.0 1 74/74 100/100 80/80 100/100
15 TCH181C3 AYHHTRM336A 27.0/36.0 2 108/122 110/125 115/130 125/150
AYHHTRM354A 40.5/54.0 2 154/176 175/200 162/184 175/200
AYHHTRN336A 27.0/36.0 2 115/130 125/150 125/139 125/150
17½ TCH211C3 AYHHTRN354A 40.5/54.0 2 162/184 175/200 171/193 175/200
AYHHTRN372A 54.0/72.0 2 209/238 225/250 218/247 225/250
AYHHTRN336A 27.0/36.0 2 115/130 125/150 125/139 125/150
20 TCH241C3 AYHHTRN354A 40.5/54.0 2 162/184 175/200 171/193 175/200
AYHHTRN372A 54.0/72.0 2 209/238 225/250 218/247 225/250
AYHHTRN336A 27.0/36.0 2 125/139 150/150 — —
25 TCH301C3 AYHHTRN354A 40.5/54.0 2 171/193 175/200 — —
AYHHTRN372A 54.0/72.0 2 218/247 225/250 — —
44 RT-PRC002-EN
Electrical
Data
Table ED-9— Unit Wiring With Electric Heat (Single Point Connection) — TXV/Face-Split Evaporator Coil Option
(Downflow Only) High Efficiency
Standard Indoor Motor Oversize Indoor Motor
To Use Heater Heater Control Max Fuse Size or Max Fuse Size or
Tons With Model No. KW Rating Stages MCA Max Circuit Breaker2 MCA Max Circuit Breaker1,2
208/230 Volts Three Phase
AYDHTRK318A 13.5/18.0 1 61/68 70/70 68/76 80/80
12½ TCD151C3 AYDHTRK336A 27.0/36.0 2 108/122 110/125 115/130 125/150
AYDHTRK354A 40.5/54.0 2 154/176 175/200 162/184 175/200
AYDHTRK318A 13.5/18.0 1 74/74 100/100 80/80 90/90
15 TCD181C3 AYDHTRK336A 27.0/36.0 2 108/122 110/125 115/130 125/150
AYDHTRK354A 40.5/54.0 2 154/176 175/200 162/184 175/200
AYDHTRL336A 27.0/36.0 2 115/130 125/150 125/139 125/150
17½ TCD211C3 AYDHTRL354A 40.5/54.0 2 162/184 175/200 171/193 175/200
AYDHTRK372A 54.0/72.0 2 209/238 225/250 218/247 225/250
AYDHTRL336A 27.0/36.0 2 115/130 125/150 125/139 125/150
20 TCD241C3 AYDHTRL354A 40.5/54.0 2 162/184 175/200 171/193 175/200
AYDHTRK372A 54.0/72.0 2 209/238 225/250 218/247 225/250
AYDHTRL336A 27.0/36.0 2 125/139 150/150 — —
25 TCD301C3 AYDHTRL354A 40.5/54.0 2 171/193 175/200 — —
AYDHTRK372A 54.0/72.0 2 218/247 225/250 — —
RT-PRC002-EN 45
Electrical
Data
46 RT-PRC002-EN
Electrical (Standard
Data Efficiency)
Table ED-11— Electrical Characteristics — Compressor Motor And Condenser Motor — 60 Cycle — Standard Efficiency
Compressor Motors Condenser Fan Motors
Unit Amps1 Amps1
Tons Model No. No. Volts Phase HP2 RPM RLA LRA No. Phase HP FLA LRA
TC*150D3 2 208-230 3 6.00 3450 20.4 156 2 1 .50 3.2 8.8
TC*150D4 2 460 3 6.00 3450 10.8 75 2 1 .50 1.6 3.8
12½ TC*150DW 2 575 3 6.00 3450 8.3 54 2 1 .50 1.3 3.2
TC*150DK 2 380 3 6.0 3450 13.1 70 2 1 .50 1.9 5.2
TC*180B3 2 208-230 3 9.30/5.10 3450 31.9/20.7 253/128 2 1 .50 3.2 8.8
15 TC*180B4 2 460 3 9.30/5.10 3450 16.3/10.0 113/63 2 1 .50 1.6 3.8
TC*180BW 2 575 3 9.30/5.10 3450 13.1/7.4 85/49 2 1 .50 1.3 3.2
TC*180BK 2 380 3 9.3/5.1 3450 19.7/12.1 125/64 2 1 .50 1.9 5.2
TC*210C3 2 208-230 3 9.3/6.0 3450 31.5/20.8 253/156 2 1 1.00 5.5 18.3
17½ TC*210C4 2 460 3 9.3/6.0 3450 15.9/10.0 113/75 2 1 1.00 2.9 9.3
TC*210CW 2 575 3 9.3/6.0 3450 12.8/8.2 85/54 2 1 1.00 2.0 5.7
TC*210CK 2 380 3 9.3/6.0 3450 19.2/12.1 125/70 2 1 1.00 3.5 8.5
TC*240B3 2 208-230 3 9.30 3450 31.7 253 2 1 1.00 5.5 18.3
20 TC*240B4 2 460 3 9.30 3450 16.2 113 2 1 1.00 2.9 9.3
TC*240BW 2 575 3 9.30 3450 13.0 85 2 1 1.00 2.0 5.7
TC*240BK 2 380 3 9.3 3450 19.6 125 2 1 1.00 3.5 8.5
TC*300B3 2 208-230 3 10.00 3450 36.6 278 2 1 1.00 5.5 18.3
25 TC*300B4 2 460 3 10.00 3450 17.9 124 2 1 1.00 2.9 9.3
TC*300BW 2 575 3 10.00 3450 14.9 92 2 1 1.00 2.0 5.7
TC*300BK 2 380 3 10.0 3450 21.7 137 2 1 1.00 3.5 8.5
NOTES:
1. Amp draw for each motor; multiply value by numbers of motors to determine total amps.
2. HP for each compressor.
RT-PRC002-EN 47
Electrical
Data (High Efficiency)
Table ED-12 — Electrical Characteristics — Compressor Motor And Condenser Motor — 60 Cycle — High Efficiency
Compressor Motors Condenser Fan Motors
Unit Amps1 Amps1
Tons Model No. No. Volts Phase HP2 RPM RLA LRA No. Phase HP FLA LRA
TC*151C3 2 208-230 3 5.70 3450 20.7 156 2 1 .50 3.2 8.8
12½ TC*151C4 2 460 3 5.70 3450 10.0 75 2 1 .50 1.6 3.8
TC*151CW 2 575 3 5.70 3450 8.2 54 2 1 .50 1.3 3.2
TC*181C3 2 208-230 3 9.30/4.50 3450 31.5/16.9 253/124 2 1 .50 3.2 8.8
15 TC*181C4 2 460 3 9.30/4.50 3450 15.1/8.2 113/59.6 2 1 .50 1.6 3.8
TC*181CW 2 575 3 9.30/4.50 3450 12.1/6.6 85/49.4 2 1 .50 1.3 3.2
TC*211C3 2 208-230 3 10.0/5.70 3450 33.3/20.7 278/156 2 1 1.00 5.5 18.3
17½ TC*211C4 2 460 3 10.0/5.70 3450 16.3/10.0 124/75 2 1 1.00 2.9 9.3
TC*211CW 2 575 3 10.0/5.70 3450 13.2/8.2 92/54 2 1 1.00 2.0 5.7
TC*241C3 2 208-230 3 9.30 3450 31.6 253 2 1 1.00 5.5 18.3
20 TC*241C4 2 460 3 9.30 3450 16.1 113 2 1 1.00 2.9 9.3
TC*241CW 2 575 3 9.30 3450 12.9 85 2 1 1.00 2.0 5.7
TC*301C3 2 208-230 3 10.00 3450 37.6 278 2 1 1.00 5.5 18.3
25 TC*301C4 2 460 3 10.00 3450 18.3 124 2 1 1.00 2.9 9.3
TC*301CW 2 575 3 10.00 3450 14.9 92 2 1 1.00 2.0 5.7
NOTES:
1. Amp draw for each motor; multiply value by numbers of motors to determine total amps.
2. HP for each compressor.
Table ED-13 — Electrical Characteristics — Compressor Motor And Condenser Motor — 60 Cycle — TXV/Face-Split Evaporator Coil Option
(Downflow Only) – High Efficiency
Compressor Motors Condenser Fan Motors
Unit Amps1 Amps1
2
Tons Model No. No. Volts Phase HP RPM RLA LRA No. Phase HP FLA LRA
TCD151C3 2 208-230 3 5.7 3450 18.6 156/156 2 1 .50 3.2 8.8
12½ TCD151C4 2 460 3 5.7 3450 9.4 75/75 2 1 .50 1.6 3.8
TCD151CW 2 575 3 5.7 3450 7.4 54/54 2 1 .50 1.3 3.2
TCD181C3 2 208-230 3 9.30/4.50 3450 32.1/16.4 253/124 2 1 .50 3.2 8.8
15 TCD181C4 2 460 3 9.30/4.50 3450 15.6/8.7 113/59.6 2 1 .50 1.6 3.8
TCD181CW 2 575 3 9.30/4.50 3450 12.3/7.4 85/49.4 2 1 .50 1.3 3.2
TCD211C3 2 208-230 3 10.00/5.7 3450 34.8/19.5 278/156 2 1 1.00 5.5 18.3
17½ TCD211C4 2 460 3 10.00/5.7 3450 17.0/10.3 124/75 2 1 1.00 2.9 9.3
TCD211CW 2 575 3 10.00/5.7 3450 13.8/8.1 92/54 2 1 1.00 2.0 5.7
TCD241C3 2 208-230 3 9.0/9.3 3500/3450 30.4/32.6 225/253 2 1 1.00 5.5 18.3
20 TCD241C4 2 460 3 9.0/9.3 3500/3450 16.1/16.8 114/113 2 1 1.00 2.9 9.3
TCD241CW 2 575 3 9.0/9.3 3500/3450 12.5/13.4 80/85 2 1 1.00 2.0 5.7
TCD301C3 2 208-230 3 10.00 3450 36.2 278 2 1 1.00 5.5 18.3
25 TCD301C4 2 460 3 10.00 3450 17.7 124 2 1 1.00 2.9 9.3
TCD301CW 2 575 3 10.00 3450 14.3 92 2 1 1.00 2.0 5.7
NOTES:
1. Amp draw for each motor; multiply value by numbers of motors to determine total amps.
2. HP for each compressor.
48 RT-PRC002-EN
Jobsite
Connections
RT-PRC002-EN 49
Typical (12½-25 Ton)
Wiring
50 RT-PRC002-EN
Typical (12½-25 Ton)
Wiring
RT-PRC002-EN 51
Typical (12½-25 Ton)
Wiring
52 RT-PRC002-EN
Typical (12½-25 Ton)
Wiring
RT-PRC002-EN 53
Dimensional (12½ Ton) High Efficiency
Data (12½, 15, 17½ Ton) Std.
Efficiency
NOTE:
Duct flanges mount 7-7/16" down
inside the curb on the 1½" curb
flanges. See recommended duct
dimensions on the next page.
Roofcurb is intended for
downflow use only.
54 RT-PRC002-EN
Dimensional (12½ Ton) High Efficiency
Data (12½, 15, 17½ Ton) Std.
Efficiency
59 7/16"
26 5/16"
52 1/2" 1"
1 1\2"
PERIMETER
14 1/16" CURB FLANGE
N
7 7/16"
T UR
RE
LY
PP
SU
NOTE:
Duct flanges mount 7-7/16" down
inside the curb on the 1½" curb
flanges.
Roofcurb is intended for
downflow use only.
RT-PRC002-EN 55
Dimensional (15-25 Ton) High Efficiency
Data (20, 25 Ton) Std. Efficiency
NOTE:
Duct flanges mount 7-7/16" down
inside the curb on the 1½" curb
flanges. See recommended duct
dimensions on the next page.
Downflow Unit Clearance
Roofcurb is intended for
downflow use only.
56 RT-PRC002-EN
Dimensional (15-25 Ton) High Efficiency
Data (20, 25 Ton) Std. Efficiency
73 7/16"
26 5/16"
66 1/2" 1"
1 1\2"
PERIMETER
14 1/16" CURB FLANGE
N
7 7/16"
T UR
RE
Y
PPL
SU
NOTE:
Duct flanges mount 7-7/16" down
inside the curb on the 1½" curb
flanges.
Roofcurb is intended for
downflow use only.
RT-PRC002-EN 57
Dimensional (12½-25 Ton)
Data Accessories
Note:
When applying economizer to horizontal units,
connecting ductwork must be run full size to
allow proper operation of Economizer Damper.
Table DD-1
Unit
Model # A B1 C2
1
TC*150, 151-180, 210 17 /2 53¾ 36
TC*181, 211-301 191/2 64¾ 39
NOTES:
1. Horizontal dimension only. Downflow economizer is width of
end panel.
2. Power exhaust is applied on downflow economizer only.
58 RT-PRC002-EN
Dimensional Factory Installed
Data Options (FIOPS)
Table DD-2
Unit
Model # A B C
TCD150, 151, 180, 210 423/8 483/8 31
TCD181, 211-301 291/2 56 381/2
RT-PRC002-EN 59
Dimensional Factory Installed
Data Options (FIOPS)
Disconnect Switch
or Circuit Breaker
Fan Failure Switch
60 RT-PRC002-EN
Dimensional (12½-25 Ton)
Data
RT-PRC002-EN 61
Weights (12½-25 Ton)
NOTES:
1. Net weight should be added to unit weight when ordering factory installed accessories.
2. For 600V heaters net weights are same as 480V heaters.
3. To estimate shipping weight add 5 lbs to net weight.
4. Downflow only.
5. Not available on all models (See Fan Performance tables for specific models).
6. 9 - 23 KW Heaters not available for TC*210C.
7. TC150-300 factory installed options for economizers, multiply net capacity x .99, EER x .97. For oversized motors, multiply net capacity x .98, EER x .93.
This is provided in compliance with ARI certification program.
62 RT-PRC002-EN
Weights
Table W-2 — Maximum Unit And Corner Weights (Lbs) And Center Of Gravity Dimensions (In.)
Unit Maximum Weights (Lbs) Corner Weights (Lbs)1 Center of Gravity (In.)
Tons Model No. Shipping2 Net A B C D Length Width
12½ TC*150D/TC*151C 1687/1776 1319/1408 446/474 339/349 230/248 303/337 46/45 29/30
15 TC*180B/TC*181C 1866/2297 1498/1838 547/627 358/461 234/317 359/431 42/52 28/35
17½ TC*210C/TC*211C 2022/2380 1654/1921 565/643 425/495 285/341 378/442 46/53 29/35
20 TC*240B/TC*241C 2372/2470 1913/2011 679/692 482/523 312/343 440/453 51/53 34/34
25 TC*300B/ TC*301C 2365/2475 1906/2016 661/695 507/524 320/343 418/454 53/53 33/34
NOTES:
1. Corner weights are given for information only. 12½-25 ton models must be supported continuously by a curb or equivalent frame support.
2. Weights are approximate. Horizontal and downflow unit and corner weights may vary slightly.
RT-PRC002-EN 63
Weights
NOTES:
1. Weights for FIOP accessories not listed are <5 lbs.
2. Net weight should be added to unit weight when ordering factory installed accessories.
3. See Table W-1 for standard factory installed economizer, electric heater and oversized motor.
64 RT-PRC002-EN
Mechanical
Specifications
RT-PRC002-EN 65
Mechanical
Specifications
66 RT-PRC002-EN
Mechanical
Specifications
Additional Factory Installed Powered or Unpowered Convenience Trane Communications Interface (TCI)
Options (FIOPS) Outlet An option for a factory installedTrane
This option is a GFCI, 120v/15amp, 2 plug, Communication Interface is available to
Electric Heaters convenience outlet, either powered or allow twisted wire pair communication
Factory installed and wired electric unpowered. When the convenience outlet with an Integrated Comfort ™ System.
heaters are available for all 3 phase is powered, a service receptacle Order this option when a combination of
horizontal and downflow 12½ - 25 ton disconnect will be available.The TCI and oversized motor is desired.
models. If ordering theThrough the Base convenience outlet is powered from the
Electrical option with an Electric Heater, Discharge Air Sensing Kit
line side of the disconnect or circuit This kit provides true discharge air
the heater must be factory installed breaker, and therefore will not be sensing in heating models.This sensor is
Through the Base Electrical With affected by the position of the disconnect a status indicator readable through
Disconnect Switch or circuit breaker.This option can only be Tracer™ orTracker™. The kit is functional
Factory installed 3-pole, molded case, ordered when theThrough the Base only with the ReliaTel Options Module.
disconnect switch with provisions for Electrical with either the Disconnect
through the base electrical connections Switch or Circuit Breaker option is Coil Guards
are available.The disconnect switch will ordered.This option is available on all Quality, tooless hail/coil guards shall be
be installed in the unit in a water tight 12½ -25 ton downflow models. either factory or field-installed for
enclosure with access through a swinging condenser coil protection.
Clogged Filter/Fan Failure Switch
door. Factory wiring will be provided from A dedicated differential pressure switch is High Efficiency Motors
the switch to the unit high voltage available to achieve active fan failure This option is available with efficiency
terminal block.The switch will be UL/CSA indication and/or clogged filter indication. ratings from 86.5 up to 91.0. Not available
agency recognized. Note:The disconnect These indications will be registered with for all models.
switch will be sized per NEC and UL either a zone sensor with status indication Supply and/or Return Air Smoke
guidelines but will not be used in place of lights or an Integrated Comfort™ System. Detector
unit overcurrent protection.This option is With this option installed, if smoke is
available on all 12½-25 ton downflow Reference or Comparative Enthalpy
Reference or Comparative Enthalpy detected, all unit operation will be shut
models. down. Reset will be manual at the unit.
option shall be available when a factory
Through the Base Electrical with Circuit installed Downflow Economizer is Return Air Smoke Detectors require
Breaker ordered.This option is available on all minimum allowable airflow when used
This option is a factory installed, thermal 12½-25 ton downflow models. with certain models. See the Installation,
magnetic, molded case, HACR Circuit Operation, and Maintenance (IOM)
Breaker with provisions for through the High Pressure Cutout manual for the models affected and the
base electrical connections.The circuit This option is offered for units that do not minimum allowable airflow required.This
breaker will be installed in a water tight have High Pressure cutout as standard. option is available on all 12½-25 ton
enclosure in the unit with access through The units with High Pressure Cutout as downflow models.
a swinging door. Factory wiring will be standard are TC*180-301B,C.
Black Epoxy Coated Condenser Coil
provided from the switch to the unit high Hinged Access Doors The coil provides corrosion protection to
voltage terminal block.The circuit breaker Sheet metal hinges are available factory condenser coils for seacoast application.
will provide overcurrent protection, be installed on the Filter/Evaporator Access The protection is a factory applied
sized per NEC and UL guidelines, and be Door and the Compressor/Control Access thermoset vinyl coating, bonded to
agency recognized by UL/CSA.This option Door.This option is available on all 12½- normal aluminum fin stock.The uniform
is available on all 12½-25 ton downflow 25 ton downflow models. thickness of the bonded vinyl layer
models. exhibits excellent corrosion protection in
salt spray tests performed in accordance
with ASTM B117.
RT-PRC002-EN 67
Mechanical
Specifications
Frostat
This factory or field installed option is to
be utilized as a safety device. The Frostat
opens when temperatures on the
evaporator coil fall below 10°F. The
temperature will need to rise to 50°F
before closing.This option should be
utilized in low airflow or high outside air
applications.
Novar Unit Controls
Novar rooftop unit controls will be factory
installed and tested.The Novar electronic
thermostat module will interface to the
unit microprocessor and will control the
unit to the desired stage of cooling or
heating.The Novar electronic thermostat
module will monitor the following unit
information: fan failure status, cooling
stage 1 on status, cooling stage 2 on
status, heating on status, clogged filter
status or unit shutdown status, and
discharge air temperature. The Novar
electronic thermostat module will have
the ability to enable the unit mounted
economizer.
Novar Return Air Sensor
This option, when used in conjunction
with Novar Controls, will contain a factory
provided wired zone temperature sensor
located in the return air stream.
Through the Base Utilities Access
An electrical service entrance shall be
provided allowing electrical access for
both control and main power connections
inside the curb and through the base of
the unit. Option will allow for field
installation of liquid-tight conduit and an
external field installed disconnect switch.
Two Inch Permanent Filters
Optional two inch permanent filters shall
be available for 12½-25 ton models.
Thermal Expansion Valve/Face-Split
Evaporator Coil Option
All units shall have a short orifice
refrigerant control metering device. For
more exact refrigerant flow, when using
units in low airflow or high outside air
applications, aThermal Expansion Valve
option shall be available.This option
includes a face-split evaporator coil which
increases part load and latent capacity.
68 RT-PRC002-EN
RT-PRC002-EN 69
70 RT-PRC002-EN
RT-PRC002-EN 71
*High Efficiency Units only