0% found this document useful (0 votes)
31 views7 pages

10 14 00.10 Exterior Signage

The document outlines the specifications for exterior signage for the Unaccompanied Enlisted Personnel Housing at USAG Humphreys, Korea. It details general requirements, product specifications, and execution guidelines, including materials, installation methods, and compliance with various standards. The signage must be designed to withstand specific wind loads and adhere to accessibility requirements, with all components sourced from a single manufacturer.

Uploaded by

hgkim76
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views7 pages

10 14 00.10 Exterior Signage

The document outlines the specifications for exterior signage for the Unaccompanied Enlisted Personnel Housing at USAG Humphreys, Korea. It details general requirements, product specifications, and execution guidelines, including materials, installation methods, and compliance with various standards. The signage must be designed to withstand specific wind loads and adhere to accessibility requirements, with all components sourced from a single manufacturer.

Uploaded by

hgkim76
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

CY21 ROKFC IN-KIND A20R210P2, UNACCOMPANIED ENLISTED

PERSONNEL HOUSING (UEPH 100B), USAG HUMPHREYS, KOREA

SECTION TABLE OF CONTENTS

DIVISION 10 - SPECIALTIES

SECTION 10 14 00.10

EXTERIOR SIGNAGE

PART 1 GENERAL

1.1 REFERENCES
1.2 GENERAL REQUIREMENTS
1.2.1 Wind Load Requirements
1.2.2 Character Proportions and Heights
1.3 SUBMITTALS
1.4 QUALIFICATIONS
1.5 DELIVERY AND STORAGE
1.6 WARRANTY

PART 2 PRODUCTS

2.1 MODULAR EXTERIOR SIGNAGE SYSTEM


2.1.1 Panel And Post/Panel Type Signs
2.1.1.1 Posts
2.1.1.2 Panel Framing System
2.1.1.3 Panels
2.1.1.4 Finishes
2.1.1.5 Mounting
2.2 GRAPHICS FOR EXTERIOR SIGNAGE SYSTEMS
2.2.1 Graphics
2.2.2 Messages
2.3 ALUMINUM ALLOY PRODUCTS
2.4 ORGANIC COATING
2.5 STEEL PRODUCTS
2.6 ANCHORS AND FASTENERS
2.7 SHOP FABRICATION AND MANUFACTURE
2.7.1 Factory Workmanship
2.7.2 Dissimilar Materials
2.7.3 Shop Painting
2.8 COLOR, FINISH, AND CONTRAST

PART 3 EXECUTION

3.1 INSTALLATION
3.1.1 Anchorage
3.1.2 Protection and Cleaning
3.2 FIELD PAINTED FINISH

-- End of Section Table of Contents --

SECTION 10 14 00.10 Page 1


CY21 ROKFC IN-KIND A20R210P2, UNACCOMPANIED ENLISTED
PERSONNEL HOUSING (UEPH 100B), USAG HUMPHREYS, KOREA

SECTION 10 14 00.10

EXTERIOR SIGNAGE

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the


extent referenced. The publications are referred to within the text by the
basic designation only.

AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)

ASCE 7-16 (2017; Errata 2018; Supp 1 2018) Minimum


Design Loads and Associated Criteria for
Buildings and Other Structures

AMERICAN WELDING SOCIETY (AWS)

AWS C1.1M/C1.1 (2012) Recommended Practices for


Resistance Welding

AWS D1.1/D1.1M (2020) Structural Welding Code - Steel

AWS D1.2/D1.2M (2014; Errata 1 2014; Errata 2 2020)


Structural Welding Code - Aluminum

ASTM INTERNATIONAL (ASTM)

ASTM A36/A36M (2019) Standard Specification for Carbon


Structural Steel

ASTM A123/A123M (2017) Standard Specification for Zinc


(Hot-Dip Galvanized) Coatings on Iron and
Steel Products

ASTM A653/A653M (2020) Standard Specification for Steel


Sheet, Zinc-Coated (Galvanized) or
Zinc-Iron Alloy-Coated (Galvannealed) by
the Hot-Dip Process

ASTM A924/A924M (2019) Standard Specification for General


Requirements for Steel Sheet,
Metallic-Coated by the Hot-Dip Process

ASTM A1011/A1011M (2018a) Standard Specification for Steel


Sheet and Strip, Hot-Rolled, Carbon,
Structural, High-Strength Low-Alloy,
High-Strength Low-Alloy with Improved
Formability, and Ultra-High Strength

ASTM B26/B26M (2014; E 2015) Standard Specification for


Aluminum-Alloy Sand Castings

SECTION 10 14 00.10 Page 2


CY21 ROKFC IN-KIND A20R210P2, UNACCOMPANIED ENLISTED
PERSONNEL HOUSING (UEPH 100B), USAG HUMPHREYS, KOREA

ASTM B108/B108M (2019) Standard Specification for


Aluminum-Alloy Permanent Mold Castings

ASTM B209M (2014) Standard Specification for Aluminum


and Aluminum-Alloy Sheet and Plate (Metric)

ASTM B221M (2013) Standard Specification for Aluminum


and Aluminum-Alloy Extruded Bars, Rods,
Wire, Profiles, and Tubes (Metric)

NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)

NAAMM AMP 500 (2006) Metal Finishes Manual

KOREAN INDUSTRIAL STANDARDS (KS)

KS D 3503 (2018) Rolled Steels for General Structure

KS D 6701 (2018) Aluminium and Aluminium Alloy


Sheets and Plates, Strips and Coiled Sheets

KS D 6759 (2017) Aluminum and Aluminum Alloy


Extruded Shapes

KS D 8308 (2016) Zinc Hot Dip Galvanizings

1.2 GENERAL REQUIREMENTS

All exterior signage must be provided by a single manufacturer. Exterior


signage must be of the design, detail, sizes, types, and message content
shown on the drawings, must conform to the requirements specified, and must
be provided at the locations indicated. Submit exterior signage schedule
in electronic media with spread sheet format. Spread sheet must include
sign location, sign type, and message. Signs must be complete with
lettering, framing as detailed, and related components for a complete
installation. Each sample must consist of a complete sign panel with
letters and symbols. Samples may be installed in the work, provided each
sample is identified and location recorded. Submit two color samples for
each material requiring color and 305 mm square sample of sign face color
sample.

1.2.1 Wind Load Requirements

Exterior signage must be designed to withstand the windload determined by


ASCE 7-16 for the wind speed at the project site as indicated. Submit
design analysis and supporting calculations performed in support of
specified signage.

1.2.2 Character Proportions and Heights

Letters and numbers on indicated signs for handicapped-accessible buildings


must have a width-to-height ratio between 3:5 and 1:1 and a
stroke-width-to-height ratio between 1:5 and 1:10. Characters and numbers
on indicated signs must be sized according to the viewing distance from
which they are to be read. The minimum height is measured using an upper
case letter "X". Lower case characters are permitted.

SECTION 10 14 00.10 Page 3


CY21 ROKFC IN-KIND A20R210P2, UNACCOMPANIED ENLISTED
PERSONNEL HOUSING (UEPH 100B), USAG HUMPHREYS, KOREA

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;


submittals not having a "G" designation are for information only. When
used, a designation following the "G" designation identifies the office
that will review the submittal for the Government. Submittals with an "S"
are for inclusion in the Sustainability eNotebook, in conformance to
Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in
accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Approved Detail Drawings; G

SD-03 Product Data

Modular Exterior Signage System

Installation

Exterior Signage; G

Wind Load Requirements

SD-04 Samples

Exterior Signage; G

1.4 QUALIFICATIONS

Signs, plaques, and dimensional letters must be the standard product of a


manufacturer regularly engaged in the manufacture of the products. Items
of equipment must essentially duplicate equipment that has been in
satisfactory use at least 2 years prior to bid opening.

1.5 DELIVERY AND STORAGE

Materials must be wrapped for shipment and storage, delivered to the


jobsite in manufacturer's original packaging, and stored in a clean, dry
area in accordance with manufacturer's instructions.

1.6 WARRANTY

Manufacturer's standard performance guarantees or warranties that extend


beyond a one year period must be provided.

PART 2 PRODUCTS

2.1 MODULAR EXTERIOR SIGNAGE SYSTEM

Exterior signage must consist of a system of coordinated directional,


identification, and regulatory type signs located where shown. Dimensions,
details, materials, message content, and design of signage must be as
shown. Submit manufacturer's descriptive data and catalog cuts.

SECTION 10 14 00.10 Page 4


CY21 ROKFC IN-KIND A20R210P2, UNACCOMPANIED ENLISTED
PERSONNEL HOUSING (UEPH 100B), USAG HUMPHREYS, KOREA

2.1.1 Panel And Post/Panel Type Signs

2.1.1.1 Posts

One-piece aluminum or galvanized steel posts must be provided with minimum


3.2 mm wall thickness. Posts must be designed to accept panel framing
system described. The post must be designed to permit attachment of panel
framing system without exposed fasteners. Caps must be provided for each
post.

2.1.1.2 Panel Framing System

Panel framing consisting of aluminum sections and interlocking track


components must be designed to interlock with posts with concealed
fasteners.

2.1.1.3 Panels

Modular message panels must be provided in sizes shown on drawings. Panels


must be fabricated a minimum of 3.2 mm aluminum. Panels must be designed
to be interchangeable.

2.1.1.4 Finishes

Post and metal panel system finish must be semi-gloss baked enamel or
two-component acrylic polyurethane.

2.1.1.5 Mounting

Provide permanent mounting by embedding posts in concrete foundation as


indicated.

2.2 GRAPHICS FOR EXTERIOR SIGNAGE SYSTEMS

2.2.1 Graphics

Signage graphics must conform to the following:

a. Message must be applied to panel using the silkscreen process.


Silkscreened images must be executed with photo screens prepared from
original art. Handcut screens will not be accepted. Original art must
be defined as artwork that is a first generation pattern of the
original specified art. Edges and corners must be clean. Rounded
corners, cut or ragged edges, edge buildup, bleeding or surfaces
pinholes will not be accepted.

2.2.2 Messages

See drawings for message content. Typeface: Helvetica medium. Type size
as indicated.

2.3 ALUMINUM ALLOY PRODUCTS

Aluminum alloy products must conform to ASTM B209M or KS D 6701 for sheet
or plate, ASTM B221M or KS D 6759 for extrusions and ASTM B26/B26M or
ASTM B108/B108M for castings. Aluminum extrusions must be provided at least
3 mm thick and aluminum plate or sheet at least 16 gauge thick. Welding
for aluminum products must conform to AWS C1.1M/C1.1.

SECTION 10 14 00.10 Page 5


CY21 ROKFC IN-KIND A20R210P2, UNACCOMPANIED ENLISTED
PERSONNEL HOUSING (UEPH 100B), USAG HUMPHREYS, KOREA

2.4 ORGANIC COATING

Clean, prime and give surfaces a semi-gloss baked enamel or two-component


acrylic polyurethane finish in accordance with NAAMM AMP 500, AMP 505, with
total dry film thickness not less than 0.030 mm.

2.5 STEEL PRODUCTS

Structural steel products must conform to ASTM A36/A36M or KS D 3503.


Sheet and strip steel products must conform to ASTM A1011/A1011M. Welding
for steel products must conform to AWS D1.2/D1.2M.

2.6 ANCHORS AND FASTENERS

Exposed anchor and fastener materials must be compatible with metal to


which applied and must match in color and finish and must be non-rusting,
non-corroding, and non-staining. Exposed fasteners must be tamper-proof.

2.7 SHOP FABRICATION AND MANUFACTURE

2.7.1 Factory Workmanship

Work must be assembled in the shop, as far as practical, ready for


installation at the site. Work that cannot be shop assembled must be given
a trial fit in the shop to ensure proper field assembly. Holes for bolts
and screws must be drilled or punched. Drilling and punching must produce
clean, true lines and surfaces. Welding to or on structural steel must be
in accordance with AWS D1.1/D1.1M. Welding must be continuous along the
entire area of contact. Exposed welds must be ground smooth. Exposed
surfaces of work must have a smooth finish and exposed riveting must be
flush. Fastenings must be concealed where practical. Items specified to
be galvanized must be by hot-dip process after fabrication if practical.
Galvanization must be in accordance with ASTM A123/A123M, ASTM A653/A653M,
or KS D 8308, as applicable. Other metallic coatings of steel sheet must
be in accordance with ASTM A924/A924M. Joints exposed to the weather must
be formed to exclude water. Drainage and weep holes must be included as
required to prevent condensation buildup.

2.7.2 Dissimilar Materials

Where dissimilar metals are in contact, or where aluminum is in contact


with concrete, mortar, masonry, wet or pressure-treated wood, or absorptive
materials subject to wetting, the surfaces must be protected with a coat of
asphalt varnish or a coat of zinc-molybdate primer to prevent galvanic or
corrosive action.

2.7.3 Shop Painting

Surfaces of miscellaneous metal work, except nonferrous metal, corrosion


resisting steel, and zinc-coated work, must be given one coat of
zinc-molybdate primer or an approved rust-resisting treatment and metallic
primer in accordance with manufacturer's standard practice. Surfaces of
items to be embedded in concrete must not be painted. Upon completion of
work, damaged surfaces must be recoated.

2.8 COLOR, FINISH, AND CONTRAST

Color must be as indicated on the drawings. For buildings required to be


handicapped-accessible, the characters and background of signs must be

SECTION 10 14 00.10 Page 6


CY21 ROKFC IN-KIND A20R210P2, UNACCOMPANIED ENLISTED
PERSONNEL HOUSING (UEPH 100B), USAG HUMPHREYS, KOREA

eggshell, matte, or other non-glare finish. Characters and symbols must


contrast with their background - either light characters on a dark
background or dark characters on a light background.

PART 3 EXECUTION

3.1 INSTALLATION

Signs, plaques, or dimensional letters must be installed in accordance with


approved manufacturer's instructions at locations shown on the approved
detail drawings; submit drawings showing elevations of each type of sign;
dimensions, details, and methods of mounting or anchoring; shape and
thickness of materials; and details of construction. A schedule showing
the location, each sign type, and message must be included. Signs must be
installed plumb and true at mounting heights indicated, and by method shown
or specified. Signs mounted on other surfaces must not be installed until
finishes on such surfaces have been completed. Submit manufacturer's
installation instructions and cleaning instructions.

3.1.1 Anchorage

Anchorage and fastener materials must be in accordance with approved


manufacturer's instructions for the indicated substrate. Anchorage not
otherwise specified or indicated must include slotted inserts, expansion
shields, and powder-driven fasteners when approved for concrete; toggle
bolts and through bolts for masonry; machine carriage bolts for steel; lag
bolts and screws for wood.

3.1.2 Protection and Cleaning

The work must be protected against damage during construction. Hardware


and electrical equipment must be adjusted for proper operation. Glass,
frames, and other sign surfaces must be cleaned in accordance with
manufacturer's instructions. After signs are completed and inspected,
cover all project identification, directional, and other signs which may
mislead the public. Covering must be maintained until instructed to be
removed by the Contracting Officer or until the facility is to be opened
for business. Submit two hard copies of maintenance instructions listing
routine maintenance procedures, possible breakdowns and repairs, and
troubleshooting guides. The instructions must include simplified diagrams
for the equipment as installed. Signs must be cleaned, as required, at
time of cover removal.

3.2 FIELD PAINTED FINISH

Miscellaneous metals and frames must be field painted in accordance with


Section 09 90 00 PAINTS AND COATINGS. Anodized metals, masonry, and glass
must be protected from paint. Finish must be free of scratches or other
blemishes.

-- End of Section --