0% found this document useful (0 votes)
10 views28 pages

SL 4035SD Eop

The SL-4035SD is an Integrating Sound Level Meter with SD card datalogger that meets IEC 61672 class 2 standards, featuring frequency and time weighting options. It offers precise measurements of sound pressure levels (SPL) and equivalent continuous noise levels (Leq), with capabilities for data recording and easy transfer to a computer. The device is designed for durability and includes various advanced settings, making it suitable for long-term use in precision sound measurement applications.

Uploaded by

Achmad Bayy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views28 pages

SL 4035SD Eop

The SL-4035SD is an Integrating Sound Level Meter with SD card datalogger that meets IEC 61672 class 2 standards, featuring frequency and time weighting options. It offers precise measurements of sound pressure levels (SPL) and equivalent continuous noise levels (Leq), with capabilities for data recording and easy transfer to a computer. The device is designed for durability and includes various advanced settings, making it suitable for long-term use in precision sound measurement applications.

Uploaded by

Achmad Bayy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 28

SD card real time datalogger, RS232/USB

Frequency weighting and Time weighting


meet IEC 61672 class 2
Integrating
SOUND LEVEL METER
Model : SL-4035SD

Your purchase of this


Integrating
SOUND LEVEL METER
with SD CARD
DATALOGGER marks a
step forward for you
into the field of
precision measurement.
Although this METER is
a complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.

OPERATION MANUAL
TABLE OF CONTENTS
1. FEATURES..............................................................................................................
1
2. SPECIFICATIONS...................................................................................................
2
3. FRONT PANEL DESCRIPTION..........................................................................
6
4. MEASURING PROCEDURE....................................................................................
7
4-1 Sound Pressure Level Measurements (SPL)......................... 7
4-2 Integrating Sound Level Meter Measurements (Leq)......................................... 8
4-3 Data Hold..........................................................................................................
10
4-4 Data Record ( Max., Min. reading )....................................................................
10
4-5 LCD Backlight ON/OFF……………………………………….. 11
5. DATALOGGER........................................................................................................
12
5-1 Preparation before execute datalogger function................................................
12
5-2 Auto Datalogger ( Set sampling time ≧ 1 second )..........................................12
5-3 Manual Datalogger ( Set sampling time = 0 second )....................................... 14
5-4 Check time and sampling time information........................................................
14
5-5 SD Card Data structure.....................................................................................
15
6. Saving data from the SD card to the computer.....................................................
16
7. ADVANCED SETTING.............................................................................................
18
7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second )................................. 18
7-2 Set sampling time ............................................................................................
19
7-3 Auto power OFF management ........................................................................
19
7-4 Set beeper Sound ON/OFF...............................................................................
20
7-5 Decimal point of SD card setting........................................................ 20
7-6 SD memory card format...................................................................................
21
7-7 Frequency weighting to A or C setting............................................................
21
8. POWER SUPPLY FROM DC ADAPTER................................................................. 22
9. BATTERY REPLACEMENT.....................................................................................
23
10. RS232 PC SERIAL INTERFACE............................................................................
23
11.CALIBRATION
FREQUENCY WEIGHTING
.......................................................................................................
CHARACTERISTICS 25
12. FREQUENCY WEIGHTING CHARACTERISTICS
OF A & C NETWORKS..........................................................................................
25
13. TIME WEIGHTING (FAST & SLOW)
CHARACTERISTICS.............................................................................................
26
14. PATENT.................................................................................................................
26
1. FEATURES
* Frequency and Time weighting are designed to meet IEC 61672 class 2.
* The meter with programmable integrating time provides precise linearity
over a wide range (100dB) and displays Leq and SPL measurements.
* A & C weighting networks comply with standards.
* 0.5" standard microphone head.
* Time weighting (Fast & Slow) dynamic characteristic modes.
* Build External calibration VR.
* Auto range & Manual range selection.
* Condenser microphone for high accuracy & long-term stability.
* Memory function to store the Max. & Min. value.
* Hold and Peak Hold functions.
* Real time SD memory card Datalogger, it Built-in Clock
and Calendar, real time data recorder, sampling time set
from 1 second to 3600 seconds.
* Manual datalogger is available ( set the sampling
time to 0 second ), during execute the manual datalogger
function, it can set the different position ( location ) No.
( position 1 to position 99 ).
* Innovation and easy operation, computer is not need to
setup extra software, after execute datalogger, just take
away the SD card from the meter and plug in the SD card
into the computer, it can download the all the measured
value with the time information ( year/month/date/
hour/minute/second ) to the Excel directly, then user can
make the further data or graphic analysis by themselves.
* SD card capacity : 1 GB to 16 GB.
* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
* Heavy duty & compact housing case.
* Leq, SPL, MAX, and MIN measurements.

1
2. SPECIFICATIONS
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 51 mm x 30 mm
LCD with green backlight ( ON/OFF ).
Measurement SPL : Sound pressure level
Type Leq : Equivalent Continuous Noise Level
Measurement 30 - 130 dB.
Range
Resolution 0.1 dB.
Function dB ( A & C frequency weighting ),
Time weighting ( Fast, Slow ),
Peak hold, Data hold
Record ( Max., Min. ).
Accuracy Characteristics of " A " frequency
(23 ±5 ℃) weighting network meet ANSI S1.4-2014 /
IEC 61672 -1 : 2013 class 2
Under 94 dB input signal, the accuracy
are :
31.5 Hz ±3.0 dB
63 Hz ±2.0 dB
125 Hz ±1.5 dB
250 Hz ±1.5 dB
500 Hz ±1.5 dB
1K Hz ±1.0 dB
2K Hz ±2.0 dB
4K Hz ±3.0 dB
8 K Hz ±5.0 dB

Remark :
The above spec. are tested under the
environment RF Field Strength less
than 3 V/M & frequency less than 30
MHz only.

2
Frequency Characteristics of A & C.
Weighting A weighting :
Network The characteristic is simulated as "Human
Ear Listing" response. Typical, if making
the environmental sound level
measurement, always select to A
weighting.

C weighting
The characteristic is near the "FLAT"
response. Typical, it is suitable for
checking the noise of machinery (Q.C.
check) & knowing the sound pressure
level of the tested equipment.
Time Fast - t = 125 ms
weighting * "Fast" range is simulated the human ear
(Fast & Slow) response time weighting.
Slow - t = 1 s
* "Slow" range is easy to get the average
values of vibration sound level.
* Proposal to test FAST & SLOW Function ,Please use
the manual range mode
Data hold To freeze the measurement value.
Peak hold To keep the peak ( max. ) measurement
value.
Range selector Auto range : 30 to 130 dB.
Manual range :
2 range, 30 to 80 dB,
80 to 130 dB, 50 dB on each step,
with over & under range indicating.
Frequency 31.5 to 8,000 Hz.
Microphone Electric condenser microphone.
type
Microphone Out size, 12.7 mm DIA. ( 1/2 inch).
size
Data error no. ≦ 0.1 % no. Of total saved data typically.

3
Calibration VR Build in external calibration VR, easy to
calibrate on 94 dB level by screw driver.
* Calibrated via external SOUND
CALIBRATOR ( SC-942, optional ).
Calibrator B & K (Bruel & kjaer), MULTIFUNCTION
ACOUSTIC CALIBRATOR Type 4226.
Datalogger Auto 1 second to 3600 seconds
Sampling Time @ Sampling time can set to 1 second,
Setting range but memory data may loss.
Manual Push the data logger button
once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Memory Card SD memory card. 1 GB to 16 GB.
Advanced * Set clock time ( Year/Month/Date,Hour/Minute/ Second )
setting * Set sampling time
* Auto power OFF management
* Set beep Sound ON/OFF
* Decimal point of SD card setting
* SD memory card Format
* Frequency weighting to A or C setting
Over Indication Show " - - - - ".
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time Approx. 1 second.
of Display
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
AC output AC 0.5 Vrms corresponding to each
range step.
* Output impedance : 600 ohm.

4
Power off Auto shut off saves battery life or
manual off by push button.
Operating 0 to 50 ℃.
Temperature
Operating Less than 85% R.H.
Humidity
Power Supply * Alkaline
AC/DC power
or heavy
adapter
duty DCis optional.
1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
* DC
AC/DC
9V adapter
power adapter
input. ( is
AC/DC
optional.
power
adapter is optional ).
Power Current Normal operation ( w/o SD card save
data and LCD Backlight is OFF) :
Approx. DC 8.2 mA.
When SD card save the data but and
LCD Backlight is OFF) :
Approx. DC 34 mA.
* If
AC/DC
LCD backlight
power adapter
on, theispower
optional.
consumption will increase approx.
6 mA.
Weight 323 g/0.71 LB.
Dimension 245 x 68 x 45 mm.
( 9.6 x 2.7x 1.8 inch ).
Accessories * Instruction manual......................................... 1 PC
Included * Hard carrying case, CA-06............................ 1 PC
Optional * Sound calibrator ( 94 dB ), SC-941.
Accessories * Sound calibrator ( 94/114 dB ), SC-942.
* Sound wind shield ball, SB-01
* SD Card ( 4 GB )
* USB cable, USB-01.
* RS232 cable, UPCB-02.
* Data Acquisition software,
SW-U801-WIN.
* AC to DC 9V adapter.
* Soft carrying case, CA-05A.

5
3. FRONT PANEL DESCRIPTION

Fig. 1

3-1 Display. 3-11 Calibration VR


3-2 Power Button(ESC, Backlight Button )3-12 RS-232 output terminal
3-3 Hold Button 3-13 DC 9V adapter socket.
3-4 REC Button 3-14 Tripod Fix Nut
3-5 ▲ Button ( Range Button ) 3-15 Battery Cover Screws
3-6 ▼ Button ( Fast/Slow/Peak Button ) 3-16 Stand
3-7 Time Button ( SET Button ) 3-17 Battery compartment/Cover
3-8 ENTER Button ( Logger Button ) 3-18 SD card socket
3-9 Microphone 3-19 Button
3-10 AC output terminal 3-20 INTEG TIME Button

6
4. MEASURING PROCEDURE
4-1 Sound Pressure Level Measurements (SPL)

In SPL mode the display shows readings of


the sound pressure level.

1) Power ON the meter by pressing and holding the " Power


Button " ( 3-2, Fig. 1 )for at least 1.5 seconds,
the meter's default function is " A frequency weighting ,
" SPL " " & " Fast time weighting "&" Auto range ". The
LCD display will show the Symbol " A.SPL, FAST , AUTO ".
Power OFF the meter by pressing and holding the " Power
Button " ( 3-2, Fig. 1 ) again for at least 1.5 seconds ,the meter will be OFF.

2) Frequency weighting select


How to select the frequency weighting ( A or C), the
procedures please refer to chapter 7-7 page 21 .
Note :
a. The characteristic table of A,C weighting, please
ref. page 25.
b. The b.characteristic
The characteristic
of A weighting
of A weighting
is simulated
is simulated
as the as
" Human theEar
" Human
Listening
Ear" Listening
response." response.
Typically
Typically
alwaysalways
select select
the A weighting
the A weighting
when makes
module when
environmental
makes environmental
sound level measurement.
sound level measurement.
c. The c.C The
weighting
C weighting
characteristic
characteristic
is nearisthe
near" FLAT
the " "FLAT "
response.
response.
Typically
Typically
it is suitable
it is suitable
for checking
for checking
the the
noise ofnoise
machinery
of machinery
( Q.C. check
( Q.C. )check
& knowing
) & knowing
the the
real sound
real level
soundoflevel
the tested
of the equipment.
tested equipment.

3) Determine proper measuring range by pressing and holding


the " ▲ Button " ( 3-5, Fig. 1 ) for at least 1.5 seconds.
until the desired range is shown (AUTO , 30 - 80 , 80 - 130 ,
AUTO) reading in the center of the range. If dashes appear
on the display select a new range , After power on the default
range is " Auto range " In the same time the LCD display
will show the text of " Auto " Under the auto range.

7
pressing and holding the " ▲ Button "( 3-5, Fig. 1 ) again
range will enter to the manual range ( range 1,range 2 )
and auto range in sequence ,There are still 2 manual ranges.
for your choice :

* Manual range 1 , 30 - 80 dB range :


Display will show the text of " 30 - 80 ".
* Manual range 2 , 80 - 130 dB range :
Display will show the text of " 80 - 130 ".

4) According to various measuring sound source, select the


Time Weighting ( Fast or Slow or PEAK Fast ) by pressing and
holding the "▼ ( Time Weighting) Button " ( 3-6, Fig. 1 ).

Note :
a. If select the function of " Fast " time weighting, the
display will show the unit of " FAST".
b. If select the function of " Slow " time weighting, the
display will show the unit of " SLOW ".
c. If select the function of " PEAK FAST " time weighting, the
display will show the unit of " PEAK FAST " and will show
maxmun reading .

4-2 Integrating Sound Level Meter Measurements (Leq)

In the Leq mode the display will shows the integrated


level for the run period readings.

1) Power ON the meter by pressing and holding the " Power


Button " ( 3-2, Fig. 1 )for at least 1.5 seconds,
the meter's default function is " A frequency weighting ,
" SPL " " & " Fast time weighting "&" Auto range ". The
LCD display will show the Symbol " A.SPL, FAST , AUTO ".

2) Select the Leq mode by pressing and holding the " INTEG
TIME button" ( 3-20 Fig 1 )>2 sec. select to the Leq MODEL .

8
3) Frequency weighting select
How to select the frequency weighting ( A or C), the procedures
please refer to chapter 7-7 page 21 .

4) According to various measuring sound source, select the


Time Weighting ( Fast or Slow ) by pressing and
holding the "▼ ( Time Weighting) Button " ( 3-6, Fig. 1 ).

5) Select the desired Run Time.,There are 13 preset time settings


available .

1 second 3 second 10 second 30 second 1 minute


5 minutes 8 minutes10 minutes 15 minutes 30 minutes
1 hour 8 hour 24 hour

Change the run time by pressing the" INTEG TIME button"


( 3-20 Fig .1 ) once, The run time will appear in the LCD
below , then Press the " ▲ buttom"( 3-5 Fig . 1 ) o r "▼ buttom"
( 3-6 Fig . 1 ) button to select the preset time setting.

Remark:
if want to do Leq data logger , Press" Enter button"( 3-8 Fig . 1 ) > 1.5
seconds , into data logger function , then to execute the following actions.

1. Press" button"( 3-19 Fig . 1 ) once to begin measuring,


The run time counter will zero and begin counting While
running the meter will Show " ► " Symbol at the display.

2. When the “ “ button"( 3-19 Fig . 1 ) is pressed again,


the measurement will pause and the display will show “‖”,
At the same time " ► " Symbol Disappear.

3. When the “ “ button is pressed again, the


measurement will continue , At the same time "‖" Symbol
Disappear and the display will show " ► "Symbol, At a
preset time interval has expired, and will display " ■ " Symbol ,
and Leq recording interval, the instrument will automatically stop.

9
6) When Integrating Time set to zero ,push " buttom "
( 3-19 Fig . 1) once, meter to begin integral measurement,At the
same time meter will Show " ► " Symbol at the display The run
time counter will zero and begin counting While running the
meter will Show " ► "Symbol at the display.
When the “ button"( 3-19 Fig . 1 ) is pressed again,
the measurement and Integrating time counter will automatically
stop , and the display will show and hold Integrating
reading and show " ■ " Symbol, at the same time " ► "
Symbol Disappear.

4-3 Data Hold

During the measurement, press the " Hold Button " ( 3-3,
Fig. 1 ) once will hold the measured value & the LCD will
display a " HOLD " symbol.
Press the " Hold Button " once again will release the data
hold function.

4-4 Data Record ( Max., Min. reading )

1) The data record function records the maximum and


minimum readings. Press the " REC Button " ( 3-4, Fig.1 )
once to start the Data Record function and there
will be a " REC " symbol on the display.

2) With the " REC " symbol on the display :


a) Press the " REC Button " ( 3-4, Fig. 1 ) once, the
" REC MAX " symbol along with the maximum value
will appear on the display.

10
b) Press the " REC Button " ( 3-4, Fig. 1 ) again, the
" REC MIN " symbol along with the minimum value
will appear on the display.

c) To exit the memory record function, just press the


" REC " button > 2 seconds at least. The display will
revert to the current reading.

4-5 LCD Backlight ON/OFF


After power ON, the " LCD Backlight " will light
automatically. During the measurement, press the
" Backlight Button " ( 3-2, Fig. 1 ) once will turn OFF the
" LCD Backlight ".
Press the " POWER Button " once again will turn ON the
" LCD Backlight " again.

*Remark :In "REC" or "LOGGER" mode , Press the


"Backlight Button" > 2 seconds , Backlight will turn ON .

11
5. DATALOGGER
5-1 Preparation before execute datalogger function
a. Insert the SD card
Prepare a " SD memory card " ( 1 GB to 16 GB, optional ),
insert the SD card into the " SD card socket " ( 3-18, Fig. 1).
The front panel of the SD card should face against the
the down case.
b. SD card Format
If SD card just the first time use into the meter, it
recommend to make the " SD card Format " at first. ,
please refer chapter 7-6 ( page 21 ).
*If the SD card exist the trouble during format by the meter,
use the computer to reformat again can fix the problem.
c. Time setting
If the meter is used at first time, it should to adjust the
clock time exactly, please refer chapter 7-1 ( page 18 ).
d. Decimal format setting
The numerical data structure of SD card is
default used the " . " as the decimal, for
example "20.6" "1000.53" . But in certain
countries ( Europe ...) is used the " , " as the
decimal point, for example " 20, 6 "
"1000,53". Under such situation, it should
change the Decimal character at first, details
of setting the Decimal point, refer to Chapter
7-5, page 20.

5-2 Auto Datalogger ( Set sampling time ≧ 1 second )

a. Start the datalogger

Press the " ENTER Button ( 3-8, Fig. 1 ) over 2 seconds into
datalogger mode , The LCD will show the text "LOGGER"
and flashing , at the same time the measuring data along
the time information will be saved into the memory circuit.

12
Remark :
How to set the sampling time, refer to Chapter 7-2,
page 19.

b. Pause the datalogger

During execute the Datalogger function , if press the


" ENTER Button " ( 3-8, Fig. 1 ) once will pause the
Datalogger function ( stop to save the measuring data
into the memory circuit temporally ). In the same time
the text of " LOGGER " will stop flashing.

Remark :
If press the " ENTER Button " ( 3-8, Fig. 1 ) once again
will execute the Datalogger again, the text of " LOGGER "
will flashing .

c. Finish the Datalogger

During pause the Datalogger, press the " ENTER Button "
( 3-8, Fig. 1) continuously at least two seconds, the " LOGGER "
indicator will be disappeared and finish the Datalogger.

Remark :
When the battery is under the low battery condition
( show the low battery indicator ), the Datalogger
function is disable.

13
5-3 Manual Datalogger ( Set sampling time = 0
second )

a. Set sampling time is to 0 second

Press the " ENTER Button ( 3-4, Fig. 1 ) at least 1.5 seconds , the LCD will
show the text " LOGGER and P = no ", then press the " ENTER Button "
( 3-8, Fig. 1 ) once, the " LOGGER " will flashing once, at the
same time the measuring data along the time information,
will be saved into the memory circuit.

Remark :
* Upper Display will show the Position/Location no.
( P = 1 - 99 ) .
* During execute the Manual Datalogger,
press the " ▲ Button " ( 3-5, Fig. 1) or
" ▼ Button " ( 3-6, Fig. 1 ) to set the measuring
position ( 1 to 99, for example room 1 to room 99 )
to identify the measurement location.

b. Finish the Datalogger

Press the "ENTER Button " ( 3-4, Fig. 1) continuously at


least two seconds, the " LOGGER " indication will be
disappeared and finish the Datalogger.

5-4 Check time and sampling time information


During the measurement if press " TIME Button "
( 3-7, Fig. 1 ) ones, the LCD display will
present the time and sampling time information of Year/Month/
Date , Hour/Minute/Second, and sampling time informationin
in second unit.

14
5-5 SD Card Data structure
1) When the SD card is used into the meter, the SD card
When the first time, the SD card is used into the meter,
the SD card will generate a folder :

SLC01

2) If the first time to execute the Datalogger,


under the route SLC01\, will generate a new
file name SLC01001.XLS.
After exist the Datalogger, then execute again,
the data will save to the SLC01001.XLS until
Data column reach to 30,000 columns, then
will generate a new file, for example SLC01002.XLS
3) Under the folder SLC01\, if the total files more
than 99 files, will generate anew route, such as
SLC02\ ........
4) The file's route structure :
SLC01\
SLC01001.XLS
SLC01002.XLS
.....................
SLC01099.XLS
SLC02\
SLC02001.XLS
SLC02002.XLS
.....................
SLC02099.XLS
SLCXX\
.....................
.....................
Remark : XX : Max. value is 10.

15
6. Saving data from the SD card
to the computer ( EXCEL software )

1) After execute the Data Logger function, take away the


SD card out from the " SD card socket " ( 3-18, Fig. 1 ).
2) Plug in the SD card into the Computer's SD card slot
( if your computer build in this installation ) or
insert the SD card into the " SD card adapter ". then
connect the " SD card adapter " into the computer.
3) Power ON the computer and run the " EXCEL software ".
Down load the saving data file ( for example the file
name : SLC01001.XLS, SLC01002.XLS ) from the SD
card to the computer. The saving data will present into
the EXCEL software screen ( for example as following
EXCEL data screens ) , then user can use those EXCEL
data to make the further Data or Graphic analysis
usefully.
EXCEL data screen ( for example )

16
EXCEL graphic screen ( for example )

17
7. ADVANCED SETTING
Under do not execute the Datalogger function,
press the " TIME Button " ( 3-7, Fig. 1 ) continuously at
least 1.5 seconds will enter the " Advanced Setting " mode.
then press the "TIME Button " (3-7, Fig. 1 ) once a while
in sequence to select the seven main function, the lower
display will show :

DATE…… Set clock time ( Year/Month/Date, Hour/Minute/


Second )
SP-T............
Set sampling time (0~3600 sec. )
POFF....... Auto power OFF management
BEEP........Set beeper sound ON/OFF
Set SD card Decimal character
DEC.............
SD- F..........SD memory card Format
A ……….... Select the Frequency weighting to A or C

During execute the " Advanced Setting " function,


if press " POWER Button " ( 3-2, Fig. 1 ) once will exit
the " Advanced Setting " function, the LCD will
return to normal screen.

7-1 Set clock time ( Year/Month/Date,


Hour/Minute/ Second )

When the lower display show " DATE "

1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to adjust the value ( Setting start from
Year value ). After the desired value is set, press the
" Enter Button " ( 3-8, Fig. 1 ) once will going to
next value adjustment ( for example, first setting
value is Year then next to adjust Month, Date, Hour,
Minute, Second value ).

18
2) After set all the time value ( Year, Month, Date, Hour,
Minute, Second ),
the screen will jump to " Sampling time "
setting screen ( Chapter 7-2 ).
Remark :
After the time value is setting, the internal clock will
run precisely even Power is off ( The battery is under
normal condition, no low battery condition ).

7-2 Set sampling time ( seconds )

When the lower display show " SP-T "

1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " (
3-6, Fig. 1 ) to adjust the value ( 0~3600 sec.)

Remark :
If select the sampling time to " 0 second ", it is ready
for manual Datalogger.

2) After the Sampling value is selected, press the


" ENTER Button " ( 3-8, Fig. 1 ) will save the setting
function with default.
7-3 Auto power OFF management

When the lower display show " POFF "

1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to select the upper text to " YES " or
" NO ".

YES - Auto Power Off management will enable.


NO - Auto Power Off management will disable.

2) After select the upper text to " YES " or " NO ", press the
" ENTER Button " ( 3-8, Fig. 1 ) will save the setting
function with default.

19
7-4 Set beeper sound ON/OFF

When the lower display show " BEEP "

1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to select the upper text to " YES " or
" NO ".

YES - Meter's beep sound will be ON with default.


NO - Meter's beep sound will be OFF with default.

2) After select the upper text to " YES " or " NO ", press the
" ENTER Button " ( 3-8, Fig. 1 ) will save the setting
function with default.

Remark :
After execute the datalogger function, the buzzer sound
will off automatically to prevent any interference of
the measurement.

7-5 Decimal point of SD card setting

The numerical data structure of SD card is default used


the " . " as the decimal, for example "20.6" "1000.53" .
But in certain countries ( Europe ...) is used the " , " as
the decimal point, for example " 20,6 " "1000,53".
Under such situation, it should change the Decimal
character at first.

When the lower display show " DEC "

1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to select the upper value to " USA " or
" EURO ".

20
USA - Use " . " as the Decimal point with default.
EURO - Use " , " as the Decimal point with default.

2) After select the upper text to " USA " or " EURO ",
press the " ENTER Button " ( 3-8, Fig. 1 ) will save the
setting function with default.

7-6 SD memory card Format

When the lower display show " SD-F "

1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " (
3-6, Fig. 1 ) to select the upper text to "YES " or
" NO ".

YES - Intend to format the SD memory card


NO - Not execute the SD memory card format

2) If select the upper to " YES ", press the " ENTER Button
" ( 3-8, Fig. 1 ) once again, the Display will show text
" YES ENTER " to confirm again, if make sure to do the
SD memory card format, then press " Enter Button "
once will format the SD memory clear all the existing
data that already saving into the SD card.

7-7 Frequency weighting to A or C setting

When the lower display show " A "

1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " (
3-6, Fig. 1 ) to select the lower text to "A " or
" C ".

A - A Frequency weighting selection.


C - C Frequency weighting selection.

21
2) After select the lower text to " A " or " C ",
press the " ENTER Button " ( 3-8, Fig. 1 ) will save the
setting function with default.

Note :
a. The characteristic table of A, C weighting, please
ref. page 25.
b. The characteristic of A weighting is simulated as
the " Human Ear Listening " response.
Typically always select the A weighting when makes
environmental sound level measurement.
c. The C weighting characteristic is near the " FLAT "
response. Typically it is suitable for checking the
noise of machinery ( Q.C. check ) & knowing the
real sound level of the tested equipment.

8. POWER SUPPLY from DC ADAPTER


The meter also can supply the power supply from the
DC 9V Power Adapter ( optional ). Insert the plug of
Power Adapter into " DC 9V Power Adapter Input Socket "
( 3-13, Fig. 1 ). The meter will permanent power ON
when use the DC ADAPTER power supply ( The power
Button function is disable ).

22
9. BATTERY REPLACEMENT
1) When the left corner of LCD display show " ", it
is necessary to replace the battery. However, in-spec.
measurement may still be made for several hours after
low battery indicator appears before the instrument
become inaccurate.
2) Loose the " Battery Cover Screws " ( 3-15, Fig. 1 )
and take away the " Battery Cover " ( 3-17, Fig. 1 )
from the instrument and remove the battery.
3) Replace with DC 1.5 V battery ( UM3, AA,
Alkaline/heavy duty ) x 6 PCs, and reinstate the cover.
4) Make sure the battery cover is secured after changing
the battery.

10. RS232 PC SERIAL INTERFACE


The instrument has RS232 PC serial interface via a 3.5
mm terminal ( 3-12, Fig. 1 ).

The data output is a 16 digit stream which can be


utilized for user's specific application.

A RS232 lead with the following connection will be


required to link the instrument with the PC serial port.

Meter PC
(9W 'D" Connector)

Center Pin............................................
Pin 4
(3.5 mm jack plug)
Ground/shield...........................................
Pin 2
2.2 K
resistor
Pin 5

23
The 16 digits data stream will be displayed in the
following format :

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0

Each digit indicates the following status :


D15 Start Word
D14 4
D13 When send the display data = 1

D12, D11 Annunciator for Display


dB = 17
D10 Polarity
0 = Positive 1 = Negative
D9 Decimal Point(DP), position from right to the
left
0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP
D8 to D1 Display reading, D1 = LSD, D8 = MSD
For example :
If the display reading is 1234, then D8 to
D1 is : 00001234
D0 End Word

RS232 FORMAT : 9600, N, 8, 1


Baud rate 9600
Parity No parity
Data bit no. 8 Data bits
Stop bit 1 Stop bit

24
11. CALIBRATION
1) Prepare the optional " SOUND CALIBRATOR ", such as
" SC-941 " or " SC-942 " ( set range to 94.0 dB ). Power
on the Sound Calibrator & plug calibrator output socket
into the " Microphone " head ( 3-9, Fig. 1 ) of the
Sound Level meter.
2) Select manual range to "80- 130 dB ".
3) Select " Time Weighting " at " Fast " position.
4) Select " A " weighting.
5) Adjust the " Calibration VR " ( 3-11, Fig. 1 ) carefully
with a " - " screw driver until the display reading value
within " 94 +/- 0.2 " dB.

12. FREQUENCY WEIGHTING


CHARACTERISTICS OF A & C
NETWORKS
Frequency A Weighting C Weighting Tolerance
Charac. Charac. ( IEC 61672
Class 2 )
31.5 Hz -39.4 dB -3 dB ±3.0 dB
63 Hz -26.2 dB -0.8 dB ±2.0 dB
125 Hz -16.1 dB -0.2 dB ±1.5 dB
250 Hz -8.6 dB 0 dB ±1.5 dB
500 Hz -3.2 dB 0 dB ±1.5 dB
1 KHz 0 dB 0 dB ±1.0 dB
2 KHz +1.2 dB -0.2 dB ±2.0 dB
4 KHz +1 dB -0.8 dB ±3.0 dB
8 KHz -1.1 dB -3 dB ±5.0 dB

25
13. TIME WEIGHTING ( FAST / SLOW )
CHARACTERISTICS
` Max. response Tolerance
Charac. ref. continuous ( IEC 61672 Class 2 )
signal
F ( Fast ) - 1.0 dB + 1.0 dB , - 2.0 dB
S ( Slow ) - 4.1 dB ±2.0 dB

14. PATENT

The meter ( SD card structure ) already


get patent or patent pending in following
countries :

Germany Nr. 20 2008 016 337.4


JAPAN 3151214
TAIWAN M 358970
M 359043
CHINA ZL 2008 2 0189918.5
ZL 2008 2 0189917.0
USA Patent pending

26 160909-SL4035SD