9607 MEADOWHILL-PLAN - 2025-01-17-Comments-1
9607 MEADOWHILL-PLAN - 2025-01-17-Comments-1
REVISIONS
Patel Residence
ADDRESS
DATE
REV
PROJECT DESCRIPTION INDEX
Patel Residence
S1.1 FOUNDATION PLAN & DETAILS
PICTURE S1.2 FOUNDATION DETAILS
COVER SHEET
A0.0
Notes:
1. Elevations are for reference only.
Please see Architectural plans for
exact elevations.
2. Wall heights shown for reference
only. Contractor to calculate all wall
heights based on top of wall
(T.O.W) elevations and foundation
embedment criteria
DESCRIPTIONS
REVISIONS
DATE
REV
INNOVATIVE DESIGN
ENGINEERING ARCHITECTURE
Site Plan
JOB NO: xxxxxxxxx
ISSUE DATE: 2025-01-17
SITE PLAN
RETAINING WALL
A1.1
Notes:
1. Elevations are for reference only.
Please see Architectural plans for
exact elevations.
2. Wall heights shown for reference
only. Contractor to calculate all wall
heights based on top of wall
(T.O.W) elevations and foundation
embedment criteria
DESCRIPTIONS
REVISIONS
DATE
Section A Section D
REV
INNOVATIVE DESIGN
ENGINEERING ARCHITECTURE
RETAINING WALL
SECTION
Bars A Bars B Bars C Bars E Bars K Bars D Bars F Bars H Bars T Bars U
WALL DIMENSIONS
BARS F
Spa.
Spa.
Spa.
Spa.
Spa.
Spa.
Spa.
Spa.
Spa.
Spa.
Size
Size
Size
Size
Size
Size
Size
Size
Size
Size
Length Length Length Length Length
(Ft) (Ft) Fw Tw Sw Hw Ft Kw Kd
2 1.5 1'-10" 0'-6" 0'-10" 0'-6" 0'-6" - - #4 10'' 2'-6" #4 10'' 2'-6" #4 10'' 1'-4" #4 10'' 1'-4" - - - #5 12'' #4 12'' #5 12'' #5 12'' #5 10''
Panel length minus 6"
2.75 2 2'-4" 0'-9" 0'-10" 0'-9" 0'-9" 1'-0" 1'-0" #4 10'' 3'-6" #4 10'' 3'-0" #4 10'' 1'-10" #4 10'' 1'-10" #4 10'' 3'-10" #5 12'' #4 12'' #5 12'' #5 12'' #5 10''
3.75 3 2'-7" 1'-0" 0'-10" 0'-9" 0'-9" 1'-0" 1'-0" #4 10'' 4'-9" #4 10'' 4'-0" #4 10'' 2'-1" #4 10'' 2'-1" #4 10'' 3'-10" #5 12'' #4 12'' #5 12'' #5 12'' #5 10''
5.00 4 3'-3" 1'-0" 0'-10" 1'-6" 1'-0" 1'-0" 1'-0" #4 10'' 6'-0" #4 10'' 5'-0" #4 10'' 2'-10" #4 10'' 2'-10" #4 10'' 3'-10" #5 12'' #4 12'' #5 12'' #5 12'' #5 10''
6.00 5 4'-0" 1'-0" 0'-10" 2'-2" 1'-0" 1'-0" 1'-0" #4 10'' 7'-0" #4 10'' 6'-0" #4 10'' 3'-6" #4 10'' 3'-6" #4 10'' 3'-10" #5 12'' #4 12'' #5 12'' #5 12'' #5 10''
DESCRIPTIONS
7.00 6 4'-9" 1'-0" 0'-10" 2'-11" 1'-0" 1'-0" 1'-0" #4 10'' 8'-0" #4 10'' 7'-0" #4 10'' 4'-3" #4 10'' 4'-3" #4 10'' 3'-10" #5 12'' #4 12'' #5 12'' #5 12'' #5 10''
BARS D, H, and T
8.00 7 5'-10" 1'-6" 0'-10" 3'-6" 1'-0" 1'-0" 1'-0" #4 10'' 9'-6" #4 10'' 8'-0" #4 10'' 5'-4" #4 10'' 5'-4" #4 10'' 3'-10" #5 12'' #4 12'' #5 12'' #5 12'' #5 10''
9.25 8 6'-10" 1'-9" 0'-10" 4'-3" 1'-3" 1'-0" 1'-0" #4 10'' 10'-9" #4 10'' 9'-0" #4 10'' 6'-4" #4 10'' 6'-4" #4 10'' 3'-10" #5 12'' #4 12'' #5 12'' #5 12'' #5 10''
REVISIONS
1'-9"
Sw
Type 10
2" waterproofing
Face of wall
footing elevations
U
Difference in
DATE
2'-0"
min. Lap
1'-0"
U
1 Sw
Face of wall 2
REV
1'-0"
1 12"
A 1'-9"
A
2" 2 12"
JOINT AND WATERSTOP DETAILS BARS Z (#5)
(Omit Bars Z when difference in top of
3" 6"
Patel Residence
F at joint
3 locations
Design Height H
Design Height H
H - 5"
H - Ft +1"
B
10" Tw + Sw - 5 12"
D
H > 5'
H ≤ 5'
undisturbed
soil Tw Hw
8" 8"
1'-0" Min
H
3"(TYP)
H-(Ft+3")
Kd
C F
4'-0"
2 Kw - 6"
Ft
3"(TYP)
Sw-7"
BARS K BARS U
3"(TYP)
E
T INNOVATIVE DESIGN
T Bottom of ENGINEERING ARCHITECTURE
footing 1 Place vertical bars inside of horizontal bars (Typical both faces).
K JOB NO: xxxxxxxxx
2 Place footing toe against undisturbed soil. ISSUE DATE: 2025-01-17
Fw 4 Retaining wall is designed for no surcharge load and soil slopes to 3:1
F (#8) x 3'-0" at
MATERIAL NOTES:
DESCRIPTIONS
1'-0" Max spacing
1. Provide Class C concrete (f’c=3,600 psi.)
2" weep holes at
2. Provide Grade 60 reinforcing steel.
10 ft. Max (slope to drain.)
REVISIONS
Recommend Filter Fabric
to cap back end of weep
CONSTRUCTION NOTES
4"dia perforated solid pipe
Finished grade. Grade to 1. Prior to construction, the site should be stripped of all organic soils. Areas that will
wrapped in filter fabric
drain away from wall. Min
3"
underlie fill, concrete, or pavement should be ripped to a depth of 6 inches and
Ponding of water near the Filter material (gravel bed)
toe of wall is not allowed compacted to a minimum of 95% of the maximum dry unit weight as determined by
ASTM D-698. Moisture contents should be at least +2 percentage points of optimum.
Top of undisturbed Filter fabric
DATE
2'-0" 3/4" Chamfer Any soft areas encountered during earthwork should be excavated to firm soils
or compacted soil. Face of wall
(pocket penetrometer reading of 2.0 tons per square foot or greater), and then filled
CONSTRUCTION JOINT using on-site materials.
1'-0"
Min
Min
12"
REV
7 1 4" 2. Provide a construction joint at about every 30'.
1 "
Limits of unclassified
8
Place toe and structural excavation
key against
GEOTECHNICAL NOTES
16"
undisturbed soil
1'-0"
7
1. It is recommended that no portion of the soil bearing strata be exposed to atmospheric
3 3 "
16" 8 conditions for more than 48 hours prior to the placement of concrete. If the surface of
the subgrade will be exposed for a greater period of time, it is recommended the
Patel Residence
8 8
inches in thickness. This is to protect the bearing surface against elements prior to
EXCAVATION DIAGRAM placement of reinforcing steel and concrete. This seal slab should be placed within 48
Note B: Use coarse aggregate to here when underdrains 2. Proper dramage should be provided behind any wall to limit the development of
are used. hydrostatic pressures. As a minimum a 4-inch diameter, perforated solid pipe wrapped
in filter fabric should be placed at the base of the wall. This pipe should be installed on
a minimum 2% slope and discharge at the end of the wall. The pipe should be placed
in a minimum 12-inch by 12- inch gravel bed. The gravel should conform to ASTM
C-33. Size 57 standards and be wrapped in filter fabric Place the pipe on the subgrade
to limit the accumulation of water. It is recommended that the bottom of the retaining
wall be protected to minimize erosion of materials Concrete pavement or a concrete
waterproofing be capped with filter fabric to limit the loss of the fine material from behind the wall.
Equal A
Type 10 C Weeps should communicate with The gravel drain behind the wall.
waterproofing 2'
4. Refer geotechnical report no: 26219G dated June 6, 2024 for additional technical
Z at 2'-0" 2'
detail
Max C
6" 6" E B
2"
E
Type 10 Z at 2'-0" Max
waterproofing Z at 2'-0"
Max
F Type 10
waterproofing
INNOVATIVE DESIGN
ENGINEERING ARCHITECTURE