NDS3508B Tuner to IP Gateway
User’s Manual
SW: 2.31
HW: 2.1
Date:20th July,2015
CHENGDU DEXIN DIGITAL TECHNOLOGY CO., LTD
DIRECTORY
CHAPTER 1 PRODUCT OUTLINE .......................................................................................... 1
1.1 Outline.................................................................................................................................................................... 1
1.2 Features .................................................................................................................................................................. 1
1.3 Inner Principle ....................................................................................................................................................... 2
1.5 Appearance and Description ................................................................................................................................ 3
CHAPTER 2 INSTALLATION GUIDE ..................................................................................... 5
2.1 Acquisition Check ................................................................................................................................................. 5
2.2 Installation Preparation........................................................................................................................................ 5
2.3 Wire’s Connection ................................................................................................................................................. 7
CHAPTER 3 OPERATION ......................................... ERRO! INDICADOR NÃO DEFINIDO.
3.1 Initializing ..................................................................................................................Erro! Indicador não definido.
3.2 General Setting ..........................................................................................................Erro! Indicador não definido.
CHAPTER 4 WEB NMS OPERATION ..................................................................................... 8
4.1 login ........................................................................................................................................................................ 8
4.2 Operation ............................................................................................................................................................... 8
CHAPTER 5 TROUBLESHOOTING ...................................................................................... 27
CHAPTER 6 PACKING LIST ................................................................................................... 28
NDS3508B Tuner to IP Gateway User’s Manual
Chapter 1 Product Outline
1.1 Outline
NDS3508B Tuner to IP Gateway is a head-end interface conversion device which
supports MPTS and SPTS output switchable. It supports 16 MPTS or 512 SPTS output
over UDP and RTP/RTSP protocol. It is integrated with tuner demodulation (or ASI input)
and gateway function, which can demodulate the signal from 16 tuners into IP package,
or directly convert the TS from ASI input and tuner into IP package, then output the IP
package through different IP address and ports. BISS function is also embedded for tuner
input to descramble your tuner input programs.
1.2 Features
⚫ Support 16 FTA DVB- S/S2 (DVB-C/T/T2 /ISDB-T optional )input, 2 ASI input
⚫ Support BISS descrambling
⚫ Support DisEqc function
⚫ 16 MPTS or 512 SPTS output (MPTS and SPTS output switchable)
⚫ 2 GE mirrored output, up to 850Mbps---SPTS
⚫ 2 independent GE output port, GE1 + GE2---MPTS
⚫ Support PID filtering, re-mapping (Only for SPTS output)
⚫ Support “Null PKT Filter” function (For MPTS for output)
⚫ Support Web operation
1
NDS3508B Tuner to IP Gateway User’s Manual
1.3 Inner Principle
Tuner 1
NDS3508B
Tuner 2
Tuner 3
GE1 IP Output
Port
1,2,3...512 SPTS
GE2 1000M
Tuner 14 Port
(for
IP Output Switch
Tuner 15
bac 1,2,3...512 SPTS
kup)
Tuner 16
ASI Input1
ASI Input2
NMS/WEB
PC
SPTS output
Tuner 1
NDS3508B
Tuner 2
Tuner 3
Pass GE1 IP Output
through Port
1,2,3...16 MPTS
(16Tuner
Input or 1000M
Tuner 14
14Tuner+2ASI GE2 IP Output Switch
Tuner 15
input) Port 1,2,3...16 MPTS
Tuner 16
ASI Input1(Optional)
ASI Input2(Optional)
NMS/WEB
PC
MPTS output
2
NDS3508B Tuner to IP Gateway User’s Manual
1.4 Specifications
Optional 1:16 tuners input +2 ASI input---SPTS output
Input Optional 2:14 tuners input +2 ASI input --- MPTS output
Optional 3:16 tuners input --- MPTS output
Standard J.83A(DVB-C), J.83B, J.83C
DVB-C Frequency In 30 MHz~1000 MHz
Constellation 16/32/64/128/256 QAM
Frequency In 30MHz ~999.999 MHz
DVB-T/T2
Bandwidth 6/7/8 M bandwidth
Input Frequency 950-2150MHz
Tuner Section DVB-S:QPSK 2~45Mbauds;
Symbol rate DVB-S2:QPSK 1~45Mbauds, 8PSK
DVB-S/S2
2~30Mbauds
Code rate 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
Constellation QPSK, 8PSK
ISDB-T Input Frequency 30-1000MHz
Input Frequency 54MHz~858MHz
ATSC
Bandwidth 6M
512 SPTS IP mirrored output over UDP and RTP/RTSP protocol through
GE1 and GE2 port, Unicast and Multicast
Output
16 MPTS IP output (for Tuner/ASI passthrough) over UDP and RTP/RTSP
protocol through GE1 and GE2 port, Unicast and Multicast
BISS
Mode 1, Mode E (Up to 850Mbps) (descramble individual program)
descrambling
Dimension(W×L×H) 482mm×410mm×44mm
Approx weight 3.6kg
Miscellaneous Environment 0~45℃(work);-20~80℃(Storage)
Power requirements 100~240VAC,50/60Hz
Power consumption 20W
1.5 Appearance and Description
Front Panel Illustration:
3
NDS3508B Tuner to IP Gateway User’s Manual
1 Power indicator
2 Reset: Reset webmaster IP address, recover it to default IP address
3 USB port for upgrade
4 NMS port: Network management interface
5 Data port(GE1&GE2): IP out port
6 ASI input port
Rear Panel Illustration
1 16 channels RF IN Interface
2 Integrated power switch and socket
3 Grounding Wire
4
NDS3508B Tuner to IP Gateway User’s Manual
Chapter 2 Installation Guide
2.1 Acquisition Check
When users open the package of the device, it is necessary to check items according to
packing list. Normally it should include the following items:
⚫ NDS3508B Tuner to IP Gateway
⚫ User’s Manual
⚫ Grounding Cable
⚫ RF In and Loop Out Cable
⚫ Power Cord
If any item is missing or mismatching with the list above, please contact local dealer.
2.2 Installation Preparation
When users install device, please follow the below steps. The details of installation will be
described at the rest part of this chapter. Users can also refer rear panel chart during the
installation.
The main content of this chapter including:
⚫ Checking the possible device missing or damage during the transportation
⚫ Preparing relevant environment for installation
⚫ Installing gateway
⚫ Connecting signal cables
⚫ Connecting communication port (if it is necessary)
2.2.1 Device’s Installation Flow Chart Illustrated as following:
Connecting
Grouding
Acquisition Fixing Connecting Setting Running
Wire and
Check Device Signal Wire Parameter Device
Power
Cord
2.2.2 Environment Requirement
5
NDS3508B Tuner to IP Gateway User’s Manual
Item Requirement
When user installs machine frame array in one machine hall, the
Machine Hall Space distance between 2 rows of machine frames should be 1.2~1.5m
and the distance against wall should be no less than 0.8m.
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
Machine Hall Floor
1X107~1X1010 ,Grounding current limiting resistance: 1M
(Floor bearing should be greater than 450Kg/㎡)
Environment 5~40℃(sustainable ),0~45℃(short time),
Temperature installing air-conditioning is recommended
Relative
20%~80% sustainable 10%~90% short time
Temperature
Pressure 86~105KPa
Installing rubber strip for sealing door-gaps and dual level
Door & Window
glasses for window
Wall It can be covered with wallpaper, or brightness less paint.
Fire Protection Fire alarm system and extinguisher
Requiring device power, air-conditioning power and lighting
power are independent to each other. Device power requires AC
Power
power 100V-240V 50/60Hz 2A. Please carefully check before
running.
2.2.3 Grounding Requirement
⚫ All function modules’ good grounding designs are the basis of reliability and stability of
devices. Also, they are the most important guarantee of lightning arresting and
interference rejection. Therefore, the system must follow this rule.
⚫ Coaxial cable’s outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
⚫ Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
⚫ Users should make sure the 2 ends of grounding wire well electric conducted and be
6
NDS3508B Tuner to IP Gateway User’s Manual
antirust.
⚫ It is prohibited to use any other device as part of grounding electric circuit
⚫ The area of the conduction between grounding wire and device’s frame should be no less
than 25mm2.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding wire
should be as short as possible and avoid circling. The area of the conduction between
grounding wire and grounding strip should be no less than 25mm2.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the power
switch, fuse, power supply socket is just beside ,whose order goes like this, power switch is
on the left ,power supply socket is on the right and the fuse is just between them.
⚫ Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC power.
⚫ Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent way,
say, share the same ground with other devices. When the device adopts united way, the
grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to NDS3508B Tuner to IP Gateway, user should set the
power switch to “OFF”.
7
NDS3508B Tuner to IP Gateway User’s Manual
Chapter 3 WEB NMS operation
User can only control and set the configuration in computer by connecting the device to web
NMS Port. User should ensure that the computer’s IP address is different from the
NDS3508Tx’s IP address; otherwise, it would cause IP conflict.
4.1 login
The default IP of this device is 192.168.2.136. Connect the pc and the device with net cable,
and use ping command to confirm they are on the same network segment.
I.G. the PC IP address is 192.168.99.252, we then change the device IP to 192.168.99.xxx (xxx
can be 0 to 255 except 252 to avoid IP conflict).
Use web browser to connect the device with PC by inputting the Encoder & Modulator’s IP
address in the browser’s address bar and press Enter.
It will display the Login interface as Figure-1. Input the Username and Password (Both the
default Username and Password are “admin”.) and then click “Sign” to start the device
setting.
Figure-1
4.2 Operation
Status
When we confirm the login, it displays the status interface as Figure-2.
8
NDS3508B Tuner to IP Gateway User’s Manual
Current software version
information
User can click any item here to enter
the corresponding interface to check
information or set the parameters.
Figure-2
Parameter→Tuner input
From the menu on top side of the webpage, click “Tuner Input”, it displays the interface
where users can check the 16 channels Tuner input status. (Figure-3)
9
NDS3508B Tuner to IP Gateway User’s Manual
16 Tuner
input status
Figure-3
Parameter→ASI input
From the menu on top side of the webpage, click “ASI Input”, it displays the interface where
users can check the 2 channels ASI input status. (Figure-4)
10
NDS3508B Tuner to IP Gateway User’s Manual
Figure-4
Parameter→BISS
From the menu on left side of the webpage, clicking “BISS”, it displays the interface where
users can configure BISS and descramble the input channels (Figure-5).
11
NDS3508B Tuner to IP Gateway User’s Manual
Select the output carrier
Figure-5
Parameter→Program Parse
From the menu on left side of the webpage, clicking “Program Parse”, it displays the interface
where users can parse the program from the input channels.
When users disable the ASI input, NDS3508B can support 16 Tuner input with 16 MPTS IP
output (Figure-6).
12
NDS3508B Tuner to IP Gateway User’s Manual
Enable and Disable the
ASI input
Figure-6
When users enable the ASI input, NDS3508B can support 14 Tuner input and 2 ASI input
with 16 MPTS IP output (Figure-7).
13
NDS3508B Tuner to IP Gateway User’s Manual
Figure-7
Parameter→IP Stream
NDS3508B supports TS to output in IP (16*MPTS) format through the GE1 or GE2 port.
Click ‘IP Stream’, it will display the interface where to set IP out parameters (Figure-8).
14
NDS3508B Tuner to IP Gateway User’s Manual
Figure-8
NDS3508B support 16 Tuner input and 2 ASI input with 512 SPTS output, the parameter
interface is different from MPTS. When users switch MPTS to SPTS, new mode will work
after reboot the device.
Parameter→Tuner Input
From the menu on top side of the webpage, click “Tuner Input”, it displays the interface
where users can check the 8 channels Tuner input status. (Figure-9)
15
NDS3508B Tuner to IP Gateway User’s Manual
16 Tuner
input status
Figure-9
Parameter→ASI Input
From the menu on top side of the webpage, click “ASI Input”, it displays the interface where
users can check the 2 channels ASI input status. (Figure-10)
16
NDS3508B Tuner to IP Gateway User’s Manual
Figure-10
Parameter→TS Config
Click “TS Config”, it displays the interface where users can set the output TS and configure
TS ID and ON ID the four output channel (Figure-11)..
17
NDS3508B Tuner to IP Gateway User’s Manual
Figure-11
Parameter→BISS:
From the menu on left side of the webpage, clicking “BISS”, it displays the interface where
users can configure BISS and descramble the input channels (Figure-12).
18
NDS3508B Tuner to IP Gateway User’s Manual
Figure-12
Parameter → SPTS Select:
From the menu on left side of the webpage, click “SPTS Select”, it displays the interface
where users can choose 16 Tuner input and 2 ASI Input programs to output from IP (max 512
SPTS). (Figure-13)
19
NDS3508B Tuner to IP Gateway User’s Manual
Input Area Output Area
Operation Area
Figure-13
Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as
below:
: To filter/not filter the source CA information
: To enable/disable the PID remapping
To refresh the input program information
To refresh the output program information
Select one input program first and click this button to transfer the selected
program to the right box to output.
Similarly, user can cancel the multiplexed programs from the right box.
To select all the input programs
To select all the output programs
To parse programs time limitation of parsing input programs
➢ Program Modification:
The multiplexed program information can be modified by clicking the program in the ‘output’
area. For example, when clicking , it triggers a dialog box (Figure 14)
where users can input new information.
20
NDS3508B Tuner to IP Gateway User’s Manual
Figure-14
System → Network:
Click ‘Network’, it will display the interface as Figure-15 where to set network parameters.
Figure-15
System → Date/Time:
From the menu on left side of the webpage, clicking “Date/Time”, it will display the screen
as Figure-16 where to set date and time for the device.
21
NDS3508B Tuner to IP Gateway User’s Manual
Figure-16
System → Password:
From the menu on left side of the webpage, clicking “Password”, it will display the screen
as Figure-17 where to set the login account and password for the web NMS.
22
NDS3508B Tuner to IP Gateway User’s Manual
Figure-17
System → Save/Restore:
From the menu on left side of the webpage, clicking “Save/Restore”, it will display the
screen as Figure-18 where to save or restore your configurations.
23
NDS3508B Tuner to IP Gateway User’s Manual
Figure-18
System → Backup/Load:
From the menu on left side of the webpage, clicking “Backup/Load”, it will display the
screen as Figure-19 where to backup or load your configurations.
24
NDS3508B Tuner to IP Gateway User’s Manual
Figure-19
System → Firmware:
From the menu on left side of the webpage, clicking “Firmware”, it will display the screen
as Figure-20 where to update firmware for the device.
25
NDS3508B Tuner to IP Gateway User’s Manual
Select IP output
Mode, click
“Apply” and
reboot the device
then the new
mode can start to
work.
Figure-20
26
NDS3508B Tuner to IP Gateway User’s Manual
Chapter 4 Troubleshooting
DEXIN’s ISO9001 quality assurance system has been approved by CQC organization. For
guarantee the products’ quality, reliability and stability. All DEXIN products have been passed
the testing and inspection before ship out factory. The testing and inspection scheme already
covers all the Optical, Electronic and Mechanical criteria which have been published by
DEXIN. To prevent potential hazard, please strictly follow the operation conditions.
Prevention Measure
⚫ Installing the device at the place in which environment temperature between 0 to 45 °C
⚫ Making sure good ventilation for the heat-sink on the rear panel and other heat-sink bores
if necessary
⚫ Checking the input AC within the power supply working range and the connection is
correct before switching on device
⚫ Checking the RF output level varies within tolerant range if it is necessary
⚫ Checking all signal cables have been properly connected
⚫ Frequently switching on/off device is prohibited; the interval between every switching
on/off must greater than 10 seconds.
Conditions need to unplug power cord
⚫ Power cord or socket damaged.
⚫ Any liquid flowed into device.
⚫ Any stuff causes circuit short
⚫ Device in damp environment
⚫ Device was suffered from physical damage
⚫ Longtime idle.
⚫ After switching on and restoring to factory setting, device still cannot work properly.
⚫ Maintenance needed
27
NDS3508B Tuner to IP Gateway User’s Manual
Chapter 5 Packing list
⚫ NDS3508B Tuner to IP gateway 1pcs
⚫ User’s manual 1pcs
⚫ Grounding cable 1pcs
⚫ RF In and Loop Out Cable 16pcs
⚫ Power cord 1pcs
28